1. KVANT Beam colour Alignment Process It is possible that due to transportation rigging moving around or vibrations caused by various elements during a set up or laser performance some of the internal optical parts can move slightly resulting in colour misalignment The colour misalignment is when two or more colours red green and blue physically do not overlay each other properly making it impossible to get nice mixed colours like yellow cyan magenta and white including all their shades If this occurs it necessary to carry out the beam alignment process Misaligned beams Warning Be very careful when aligning beams and wear sufficient laser safety protection if necessary The beam alignment process is carried out when the front cover of the optical compartment is open so there is a risk of accidental exposure to Class 4 laser radiation Beam alignment principle There are three laser colours beams within the system where one of them usually the blue one has a fixed position aiming at the centre of the bottom scanner mirror The goal of the alignment process is to align the other two red and green beams to the first one so all the beams overlay each other making it possible to mix them together for a vivid and sharp colours An easiest way to do this process is to project a full size circle so you can see it on the wall or another projection surface during the alignment That way you make sure that yo
2. KVANT We give you the power of laser light MODEL SPECIFIC INFORMANON FULL COLOUR PURE DIODE LASER SYSTEM 2014 KVANT s r o All rights reserved Written by Martin Pelikan Version 1 1 Thank you for purchasing a KVANT product To ensure proper operation please read this Model Specific Information carefully before using the product After reading it keep it in a safe place for future reference KVANT gives you the power of laser light KVANT Hem Chest Before starting check that all the following items have been included with your laser system If anything is missing contact your supplier Product Number picture of Product details units 1 Laser System KVANT ATOM 801 1 Emergency STOP remote 1 3 pin XLR Emergency STOP remote cable 1 AC power cable 1 Interlock connector 2 set of Safety keys 4 keys in total S 1 ILDA signal cable CD with Model Specific Information 1 and Instruction Manual Page 1 KVANT _ Optional Accessories Here is a list of accessories that are compatible with the ATOM 801 laser system Product picture Product details D SafeScan lens Six different lenses are available These lenses increase a 7 the divergence of the laser beam when scanning downward into the KVANT audience helping to make the show safer Make sure you fully understand the laser safety before using your laser with or without these lenses Adjustable attachment bracket for Safe
3. green circle overlays the blue circle at all points around the shape IF not use supplied 1 5mm allen key to adjust the RED adjustment socket bolts according to the picture on next page following the bolt numbers turn directions and order in which the adjustments need to be done until the red circle sits exactly on top of the blue circle 8 finally create a white static tunnel effect circle so you can clearly see the whole shape on a projection surface i e wall If you ve done the alignment process successfully you should see all the colours nicely overlaying each other resulting in even bright and sharp circle like the one on the picture below Page 8 udu Di Gi udu usuyl LUS JHL OL 1437 3H1 OL LUBOG OU SAOW O POU SGYVMNMOG SdgdVMdn Aoy u jje wuuIg asn 1104 1104 sjuau sn pe 104 av3H X3H av3H X3H INANLSNPaV ININISNFAV a34 N3345 INdiLno O JINGOW 43Ssv1 Ania dad N334d59 ewes ou s eme s ajdiound juewubipe y ING epou e uo Bulipuadap jualayip eq ueo sdnolb juauisnipe jo noAe ay jey ajou aseald MAIA ACIS JINGOW GASV 1 Page 9 KVANT Main Fuse Replacement If the system doesn t turn ON after pressing the main ON OFF switch it is likely that the main power fuse is blown and needs to be replaced Please follow the instructions below carefully when replacing the main fuse 1 make sure the laser system is switched off and unplugged from t
4. he main power supply before proceeding to the next step 2 remove 18 socket bolts that hold down the top metal cover 3 slowly remove the top cover it is necessary to detach the GND connector that is attached to the top cover from the inside of the system To detach the connector simply pull the connector out 4 remove 4 socket bolts that hold down the metal cover of the main power section 5 remove the black metal cover of the main power section 6 locate the main power fuse position red rectangle on the picture below Ka ii gt AAN Kee 5 ho 7 remove the plastic cover that covers the main fuse 8 replace the fuse with appropriate fuse T3 15A 250V T 6 3A 110V for the US Page 10 KVANT System Specification KVANT ATOM 801 full colour pure diode laser system Total Optical Power installed 930MW Total Optical Power guaranteed 800mW Red 170mWwW 637nm Green 110mWwW 520nm Blue 650mW 445nm NOHD Nominal Ocular Hazard Distance 275m Beam diameter at laser aperture 3mm Beam divergence lt 0 72mrad full angle Modulation 0 5V analog up to 50kHz Module cooling TEC Scanning System scannerMAX 506 Compact 35kpps 8 max scanning angle 60 on both axes Control signal input ILDA IN DB25 male Control signal output ILDA OUT DB25 female Power requirements 100 240V 50Hz 5 Consumption 250VA 100 240V Operation temperature 10 40 C Ingress protection rating IP54 D
5. imensions WxDxH 256 x 152 x 168mm Weight 5 7kg Integrated Laser Safety features Keyed interlock emission delay magnetic interlock when housing cover is off adjustable masking plate ScanFail circuit mechanical shutter reaction time lt 20ms Page 11
6. or to connect the laser system to power supply The main power switch needs to be switched ON for the laser to be operational The system requires 110 230V 50Hz power supply There is also a power output connector grey Powercon which can be used for daisy chaining of more systems together for an easy installation Please note that maximal number of laser systems should not exceed 8 units 10 E STOP Remote connector and Interlock status indicator In order to use the laser system the Interlock must be disabled This can be done elther by connecting the Emergency STOP Remote to the 3 pin XLR INPUT Remote socket by using supplied cable or by plugging in the supplied Interlock Connector Please note that it is a legal requirement to have a working E STOP with every laser system and that if you will use the Interlock connector for defeating the interlock you must have another method of being able to switch the laser system off remotely in case of an emergency i e electricity power cut The Interlock status indicator goes off when the Interlock is defeated and the Interlock key is in ON position Unless all above is done correctly the interlock will not allow laser emission from the system The REMOTE Output is used to daisy chain the Remote signal when you want to use a single Emergency STOP Remote to control multiple systems 11 Safety eyelet Use this together with appropriate safety wire to secure the system against unexpected fall Page 5
7. secondary mixed colours including white The system is air cooled and designed so that there is no airflow going through the optical compartment of the system This ensures that all important optical parts of the system stay clean tor longer keeping the maintenance time down to a minimum This is a real advantage for all the venues where lots of smoke or haze is used on a daily basis This laser is IP rated to IP54 meaning that it is splash proof It is however important to understand that this system was designed for indoor use and therefore it must not be exposed to rain snow or excessive amounts of dust FRONT VIEW FEATURES O laser aperture window with four socket bolts Undo these four socket bolts to remove the aperture window if you need to clean it or to install the DiscoScan 2 0 lens 1 aperture masking plate This metal masking plate can be moved up and down when two locking bolts are loosened This is an extremely useful safety feature which gives you an option to limit the bottom of the laser output area if necessary for example if audience scanning needs to be avoided The masking plate can also be attached upside down if needed using the two top holes above the aperture window 2 allen key in easily accessible front cover slot This tool can be used for all user allowed servicing procedures 3 u Turn 360 attachment bracket Especially developed attachment bracket allows you to spin it 360 degrees around the laser body whils
8. t it can also be locked in a desired position by two small handles on its side There s no need to use excessive force when locking the system in a desired position because of the sophisticated locking mechanism 4 laser emission indicator When this indicator is lit up it means that the laser system is ready to emit laser radiation as soon as it receives the instructions to do so from the control software 5 beam alignment mechanism Under this small metal plate that is held in place by 4 socket bolts you will find the beam alignment mechanism that is used for the beam alignment when necessary REAR VIEW FEATURES 1 ILDA signal In Out Use the ILDA Input connector for plugging in your laser control interface with the supplied ILDA cable The ILDA Output connector can be used to daisy chain more laser systems together when needed 2 X Y axis Invert Use these two switches when the axis are required to be reversed This can be useful when projecting a text or graphics on a rear projection surface Page 4 KVANT 3 ScanFail Safety indicator This indicates the state of the scan fail safety circuit or the Emission Delay function After every switch ON this indicator will flash for about 60 seconds during which the laser will not emit any laser radiation After this initial period the light will turn itself off and only light up again when there is a problem with the scanning system or input signal ScanFail mode selector There are t
9. tyScan lens A 3 pin XLR Emergency STOP remote cable available in various lengths ES up to 500 metres ILDA signal cable available in various lengths up to 200 meters Set of spare Safety keys DiscoScan 2 0 lens from Pangolin extends scanning capability of the system to 360 Mounting bracket for DiscoScan lens 2 0 Page 2 System Overview LASER EMISSION LASER APERTURE LASER APERTURE LASER RADIATION AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION CLASS 4 LASER PRODUCT A vovo yv gt WWW ILDA OUTPUT CAUTION CLASS 4 VISIBLE LASER RADIATION WHEN OPEN AND INTERLOCKS DEFEATED AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION 2 REMOTE 7 o m aa Di EAR e y INVERT X SIZE POSITION 4 A 0 2 c Ga POWER o G Y j e INVERT Y SIZE POSITION LED 1 START Es m mm Dm SAFETY LED 2 READY Lg KEY OFF ON OUTPUT E 7 100 240 VAC LASER PROJECTOR Model RISK OF ELECTRIC ATOM 800 SHOCK DO NOT OPEN Output power 800mW Laser class input power 100 240VAC 2 3A Fuse T315A Serial No 07314214 Page 3 The KVANT ATOM 801 is a full colour pure diode laser system that was designed for professional use When operated correctly and in the right conditions the ATOM 801 is able to deliver a strong performance in venues with up to 800 people capacity This laser can display virtually any colour within the basic RGB palette and its
10. u get all the beams aligned properly on both X and Y axes It is also good to know that longer the distance between the laser system and the projection Surface is during the alignment more precise the result will be When doing the alignment on long distances it is always good to have someone with you who can direct you Alternatively you could use binoculars Page 6 Beam alignment process 1 remove 4 socket bolts that hold down the beam alignment mechanism cover 2 the two adjustment groups will be revealed picture below one for each colour Red and Green Each group has four socket bolts that adjust the internal direction of appropriate laser beam colour 3 power up the system following the Switching ON Sequence p 6 of the User Manual and follow the alignment instructions on the next page Page 7 4 create a static tunnel effect circle so you can clearly see the whole shape on a projection surface i e wall 5 check whether the green circle overlays the blue circle at all points around the shape IF not use supplied 1 5mm allen key to adjust the GREEN adjustment socket bolts according to the picture on next page following the bolt numbers turn directions and order in which the adjustments need to be done until the green circle sits exactly on top of the blue circle 6 create a static tunnel effect circle so you can clearly see the whole shape on a projection surface i e wall 7 check whether the
11. wo modes in which the scan fail circuit can work in SCANNER the system controls the movement of both scanners If there is no movement it switches the laser emission off and keeps it off until there is a movement on both scanners detected INPUT the system checks for a difference between the input signal that goes into the laser system and the movement of galvo motors lf the system detects that there s a difference between these two signals meaning that scanning system is faulty it will switch the laser emission off Please note that in the INPUT mode the safety circuit sometimes kicks in if the scanned effect is too small 4 X Y axis Size and Position If necessary you can these control pots to adjust the size and position of the master projection zone 5 colour adjustment pots n output of each of three basic colours RGB can be manually adjusted by turning corresponding pot to the left or right Normally all the colours are adjusted in the laser control software and these pots are mainly used when taking measurements or when performing the beam alignment procedure 6 Safety key switch The Safety key must be inserted and turned to ON position in order to enable the system to operate 7 Moncha NET power connector his is used to directly power supply the Moncha NET interface which can be purchased separately 8 amp 9 Main power socket IN OUT and POWER switch Use supplied power cable with the blue Neutrik Powercon connect