FloBoss™ 107 Flow Manager LCD User Manual
Contents
1. 3 13 20071 13 31 06 ROL Hame FEIT Figure 3 69 System Parameters 2 Touch Y and AN to display various system parameters Note You can change the Contract Hour parameter Also you can touch the CPU Load option to display a chart of the current 3 Touch Exit to display the System menu 3 8 2 Saving a Configuration Use this option to save the currently active FB107 configuration to Flash memory 1 Touch Save Cfg on the System menu The Save Configuration menu displays Save Configuration Figure 3 70 Save Configuration Menu 2 Touch Yes The Touchpad displays a confirmation message saving Configuration Figure 3 71 Confirmation Message 3 The Touchpad then displays the System menu Issued Sep 07 Using the Touchpad 3 35 FB107 LCD User Manual 3 8 3 Performing a Warm Start Use this option to warm start the system from the Touchpad 1 Touch Warm Start on the System menu The Warm Start menu displays Perform Warm Start d Figure 3 72 Warm Start Menu 2 Touch Yes The Touchpad displays a confirmation message Waiting for System Festart Figure 3 73 Confirmation Message 3 When the warm start completes the Touchpad displays the default idle state display EMERSON Process Management Touch Screen bo Shark Figure 3 74 Idle State Display Note After a warm start you must log onto the Touchpad again 3 8 4 Forcing End of Day Use this option to for
2. RAS a division of Emerson Process Management FloBoss ROCLINK Bristol Bristol Babcock ControlWave TeleFlow and Helicoid are trademarks of RAS AMS PlantWeb and the PlantWeb logo are marks of Emerson Electric Co The Emerson logo is a trademark and service mark of the Emerson Electric Co All other trademarks are property of their respective owners The contents of this publication are presented for informational purposes only While every effort has been made to ensure informational accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchaser and end user 2007 Remote Automation Solutions division of Emerson Process Management All rights reserved i Issued Sep 07 FloBoss 107 LCD User Manual Contents Chapter 1 Introduction 1 1 dls SCOPE and OKGAMIZAUON EE 1 1 UE e EN 1 1 1254 DIsplay MOGE sita o toas 1 4 122 POWER SAVINGS ModE sto ii 1 5 1 2 3 Touchpad and ROCLINK 800 Security oooooncccnnccccccconncccn
3. Diagnostic nstalled Module ni Actual Module ni Description Application Firmware Revision Rev 100 Part Number weng Build Date Jul 27 2007 8 02 Serial Number w 48083 0012 C 07010049 Boot Revision fRev 1 00 0 Boot Build Date Nov 17 2006 8 32 Integrity a Auto Scan Update 952AM y Figure 2 1 FB107 Graphic Display 2 Plug the connector for the Touchpad into the Display port on your FB 107 see Figure 2 1 The Touchpad activates and displays the message Waiting for Comms Issued Sep 07 Configuration 2 1 FB107 LCD User Manual Copyright 2006 2007 LOCO Rev 1 00 Remote Automation Solutions 15 2k Baud Waiting for Comms Figure 2 2 Touchpad Activation 3 Click the Display port on the FB107 graphic The LCD Controller screen appears at the bottom of the FB107 graphic display Note that the FB107 graphic highlights the Display port and removes the integrity error on the display port ig ROCLINK 800 On Line Com1 FB107 Seles File Edit View ROC Configure Meter Utilities Tools Window Help 6 3 Dae ts Be SAE Ce WHw VR SZORB RI o WK On Line Com FB107 dee L as MI Modules Sm 1 0 EF amp Control ES KN Meier Ma System EF History User Program SE User Display Installed Module LCD Controler ActualModule LCD Controller Description Led Controller App Revision Rev 1 00 Part Number
4. cooocccccnoccnnonnncnconanonoss 3 24 3 47 RTD Verification Parameters 3 24 3 48 RTD Parameters s a o 3 24 3 49 RTD Parameters n o 3 25 3 50 RTD Parameters A 3 25 3 51 LCD User List Chart 3 26 S202 ge Ee de EE 3 26 3 53 History Men 3 27 3 54 Daily History Menu 3 27 3 05 PRISTON Char rencias cla 3 27 3 56 Dynamic Data Menu 3 28 3 57 DYNAMIC UN 3 29 3 DOs OCAIe RANGES iia 3 29 3 59 FID MENU add iia 3 30 3 60 PID Loop Men 3 30 3 61 PID Parameters Menu n n onannnnnannnnennn 3 30 3 62 Primary PID Loop Parameters 3 31 3 63 Override PID Loop Parameters 3 31 3 64 PID MOG oi iia 3 31 9 65 IDO MU tacos 3 32 3 66 PID Loop Menu 3 32 3 67 Graphical PID Loop 3 33 3 68 System Menu 3 34 3 69 System Harameters 3 35 3 70 Save Configuration Menu 3 35 3 71 Confirmation Message oooooccccnncccncc 3 35 3 72 Warm Start Men 3 36 3 73 Confirmation Message oooooccccnnncnncc 3 36 3 74 Idle State Display cccoooonconccccoooos 3 36 3 75 Force End of Day Men 3 37 3 76 Confirmation Message seseeneeean 3 37 3 77 Contrast Control Parameters 3 37 3 78 Confirmation Message oooooccccnncccncc 3 38 Forcing End of Day processing essssseneennn 3 36 H Hardware OVNIS Wa ans 1 1 HI Scale ti e socio 2 9 Historical CAMS miii ita 3 27 2 Index FB107 LCD User Manual L LIST NUDO s
5. AA ETT HK d OK OK OO OK Sg E E d d OI A Cancel i Apply Note Refer to Chapter 7 in the ROCLINK 800 Configuration Software User Manual for FloBoss 107 A6217 for complete instructions on configuring this screen Once you have configured the points on this screen you can view them on the Touchpad Touch Chart on the Modules menu The Chart menu displays 3 26 Historic Dinamic Exit lt Chart gt Figure 3 52 Chart Menu Using the Touchpad Issued Sep 07 FB107 LCD User Manual 3 6 1 Viewing Historical Data Use this option to view defined historical data points you have defined on the LCD User List Chart screen 1 Touch Historic on the Chart menu The History menu displays Exit lt History 3 Figure 3 53 History Menu Note This menu enables you to view historical data either on an hourly or daily basis The menu options on the subsequent screens are the same 2 Touch Daily on the History menu The Daily History menu displays MIMTLY CUR DP CUR SF CUR TP Exit lt Daily gt Figure 3 54 Daily History Menu 3 Touch an option on the Daily History menu A history charting screen displays MM DD at Upper scale LEA OD 000 scroll point Value s label DEE Value at current ees scroll point Time at scroll point Figure 3 55 History Chart The vertical dotted line indicates the current point on the historical record The arrows on the right side of the cha
6. Disabled Enabled Level Enabled Security op COM pi UserID User Access ennen E EE Security on LUM pu User ID User Access P Disabled Cp a Level Enabled Secunty on LEO UserID User Access o EE EE Figure 2 12 Device Security Note Use only the left hand side of this screen to define Touchpad security The right hand fields Security on LOI Security on COM1 etc do not apply to the Touchpad but do apply to security levels on the FB 107 Leave the Security on LCD field disabled It applies only 1f you are connecting a display other than the LCD from Remote Automation Solutions If that 1s the case contact Product Support 2 Click in the first empty Operator ID field The Device Security dialog box displays 2 10 Configuration Issued Sep 07 FB107 LCD User Manual Device Security User User List 1 C Disabled View Only View E dit Operator ID SRY User List 2 Password E C Disabled C View Only View E dit Contirn Password E User List 3 C Disabled C View Only View E dit User List 4 C Disabled View Only View E dit Access Level 5 Standard Lists Remove 5 Cancel C Disabled View Only View E dit Figure 2 13 Device Security User Level 3 Complete the following fields to define the access permissions for the new user ID Field Description Operator ID Sets the three alohanumeric characters for the password Password Sets the four digit pass
7. Slot 3 gt Figure 3 34 MVS Menu Note A blinking i ia or a in the upper right corner of an MVS box as in Mvs 1 and Mvs 3 in Figure 3 34 indicates an integrity or alarm issue with this transmitter 3 Touch a transmitter box A parameter screen for the MVS transmitter displays 4 PWS 1 gt DP A oopop InH Reverse DP 1H D 44444 Figure 3 35 MVS Parameters 4 Touch Y or to view additional parameter values 5 Touch Exit to display the MVS menu 6 Touch Exit to display the Modules menu 3 5 5 Viewing Meter Information The FB 107 supports up to four meters Use this option to view flow rate and alarm information for each defined meter run 1 Touch Meter on the Modules menu The Meter Run menu displays Figure 3 36 Meter Run Menu Issued Sep 07 Using the Touchpad 3 19 FB107 LCD User Manual lt Well song gt Flow Rate MCF Day El BEE MONE Figure 3 37 Meter Run Parameters 3 Touch Exit to display the Meter Run menu 4 Touch Exit to display the Modules menu 3 5 6 Viewing System Information Use the SysAI option on the Modules menu to view the following information on the FB107 s battery charging status and board temperature Battery Charging Board Temperature Volts Volts Degrees Alarms Alarms Alarms Low Volts Low Volts Low Degrees High Volts High Volts High Degrees A D Counts A D Counts A D Counts 1 Touch SysAi on the Modules me
8. 29 37h Seting Basic PID LOOPS nro a eo coa 3 30 3 7 2 Setting Advanced PID LOOPS cccccccccconnccnnncccncccoccnnnnnononnnannccnnnnnnnnnnnnncnnnnnnnnnnnns 3 32 3 05 siem IMMIONM ANON EE 3 34 3 8 1 Displaying System Information n en0annnnnneennnnonennnnesennnesrnnnreosnnrnrnsnnreressenrnee 3 34 382 SAVING a CONIguUrallON EE 3 35 309 E gege e e ERT E EE 3 36 3104 Foceno Endor DAY al tad 3 36 Issued Sep 07 Contents jii FloBoss 107 LCD User Manual 3 8 5 Adjusting Touchpad Contraet 3 37 39 e e Leinen E 3 38 Index l 1 iV Contents Issued Sep 07 FB107 LCD User Manual Chapter 1 Introduction This chapter describes the structure of this manual and presents an overview of the Liquid Crystal Display LCD for the FloBoss 107 Flow Manager 1 1 Scope and Organization 1 2 Overview Issued Sep 07 This document serves as the user manual for the FloBoss 107 Flow Manager Liquid Crystal Display LCD which is intended for use with the FloBoss 107 Flow Manager FB107 This manual describes how to install configure and use the FB107 LCD the Touchpad You initially access and configure the Touchpad using ROCLINK 800 Configuration software loaded on an IBM compatible personal computer running Windows 98 NT 4 0 with Service Pack 6 2000 with Service Pack 2 or XP Once configured the Touchpad provides access to many FB107 system parameters and functions The chapters in this manual provi
9. Display General LCD Advanced Baud Rate r bau r Data Bits r Stop Bits p Port Owner 9600 e None Ce e 1 e LCD Master 192K C Even 8 y C ROC Modbus Slave O 38 4K C Odd AN LCD Mode C Normal Valid Receive Counter fi 07120 eee songs oes Normal C Low Power Auto Scan Update Apply Issued Sep 07 B54AM y Figure 2 7 ROCLINK 800 LCD User List Configuration Options 2 Select BLM in the LCD Mode frame Click Apply to save your change ROCLINK 800 performs a warm start 3 Select Configure gt LCD User List gt BLM from the ROCLINK 800 Menu bar The LCD User List BLM screen displays Configuration 2 5 FB107 LCD User Manual LCD User List BLM Device Parameter Units AGANEW 1 CUR DP In AGANEW1 CURSP PSI AGANEW 1 CUR TP Det FLWNEW 1 FLOWDY Man LWNEW 1 ENGDAY IMMBTUDay FLW NEW 1 FLOT DY ee LANE 1 FLOYD Undefined Undefined Undefined Undefined Undefined Undefined ech 2 El 4 5 E H H J O A Ek E fea Men EIS e a a dh dd gt ek E Ww T 2 Update Y OK 2 Cancel Figure 2 8 LCD User List BLM 4 Complete the following fields to define the contents of the BLM list Field Description Title Sets a 10 character alohanumeric identifier for the list Scroll Time Indicates the number of seconds the Touchpad displays each parameter set b
10. Override The Override Parameters screen displays 2 Well gg gt Our Pu H HARE Our SP H BEBE Figure 3 63 Override PID Loop Parameters Use this screen to display the override process variable and redefine if necessary the override setpoint 6 Touch Exit to display the PID Parameters menu 7 Touch Mode to display the PID Mode screen Current Mode Auto Exit lt Well 16 gt Figure 3 64 PID Mode Issued Sep 07 Using the Touchpad 3 31 FB107 LCD User Manual Use this screen to switch the PID Control mode between Automatic and Manual 8 Touch Exit to display the PID Parameters menu 9 Touch Output to display the PID Output screen lt Well salon gt Out Put A DR Figure 3 65 PID Output Use this screen to review the current output for the PID loop 10 Touch Exit to display the PID Parameters menu 11 Touch Exit to display the PID Loop menu 12 Touch Exit to display the PID Menu 3 7 2 Setting Advanced PID Loops Use this option to access a graphic display and supporting screens that enables you to quickly review and adjust PID parameters 1 Touch Advanced on the PID menu The PID Loop menu displays Well Fi Well 268 Well 368 Well 466 Figure 3 66 PID Loop Menu 2 Touch a PID loop on the PID Loop menu The graphical PID Loop displays 3 32 Using the Touchpad Issued Sep 07 Issued Sep 07 FB107 LCD User Manual 5da T 94 45 2 F PID Loop selector wm x Inche
11. Parameter GANEW 1 CUR OP AGANEW 1 CUR SP PLANEA 1 FLOW LWiNEW 1 ENGDAY ndetined Undetined ndetined Undefined ndefined ndefined Urdefined Undefined Undefined e e Undefined JI Title List 1 Scroll Time 4 Seconds Units Deal kM3 Day GJ Day 2 Update Y OF K Cancel Figure 3 16 LCD User List 2 Complete the following fields to define the contents of each user list Field List No Description Sets the number of the LCD User List you want to configure Click w to display all defined lists You _can define up to four user lists user list Using the Touchpad Sets a 10 character alphanumeric identifier for the Issued Sep 07 Field Scroll Time Device Parameter Text Units FB107 LCD User Manual Description Indicates the number of seconds the Touchpad displays each parameter set before scrolling to the next parameter set Typically the Touchpad displays two parameters at a time Valid values are 0 do not scroll to 255 Note If you set this value to 0 you must use the A and keys on the Touchpad to manually scroll through the parameters defined in the list Sets the parameter that you want to display on the Touchpad Click to display a Select TLP screen you can use to define the parameter Sets a 10 character alphanumeric identifier for the parameter Shows the engineering units for the associated parameter 3 Click Apply if you make an
12. all the I O points defined for that module Figure 3 26 shows the options for the CPU module Exit lt Slot HA gt Figure 3 26 Module I O Points Note A blinking i la or a in the upper right corner of a point box as in AI 2 and AO 1 in Figure 3 26 indicates an integrity or alarm issue with this point 3 Touch an I O point The Touchpad displays a series of screens showing the parameters for that point AL 1 Slots gt SAL 1 Slot gt SAL 1 Slate gt EUW Low EU Value a ees A aeeee A D Counts Percent H Hp Alarms oun EU High 186 PABA Percent Exit meee Exit Calibrate IA Exit Calibrate Figure 3 27 I O Point Parameters Note The Touchpad places a box around any parameter value you can edit as with AO or DO points See Figure 3 18 4 Review the points To resolve an error condition if one exists use ROCLINK 800 to correct the situation 5 Touch Exit to display the Module I O Points screen 6 Touch Exit to display the Modules Menu screen 3 5 2 Viewing RTD Information Use this option to review data on the CPU module s Resistance Temperature Detector RTD 1 Touch Modules on the Main Menu The Modules menu displays 3 16 Using the Touchpad Issued Sep 07 FB107 LCD User Manual DH 1 E Cpu rseae ri455 Aux Exit Meter Zwei Ove Figure 3 28 Modules Menu 2 Touch Cpu An I O points screen for the CPU module displays Figure 3 29 M
13. weng 0 Build Date Dec 12 2006 7 50 Serial Number W48085X00124 06510148 Boot Revision Rew 10 Boot Build Date Dec 12 2006 711 Integrity A A Auto Scan Update 218PM y Figure 2 3 LCD Controller 4 Select the Advanced tab The Advanced screen displays 2 2 Configuration Issued Sep 07 FB107 LCD User Manual den ROCLINK 800 On Line Com1 FB107 SEE Eile Edit View ROC Configure Meter Utilities Tools Window Help EI 6 Deh eo HSG Aw VE SOR LR 2 On Line Com FB107 EEE d d zx MI Modules 10 amp Control E Meter Ma System History User Program SE User Display General LCD Advanced Baud Rate p Parity 5 T C 9600 e None 7 4 Normal 192K C Even lee LS C ROC Modbus Slave C BLM C 38 4K C Odd C 576K CD Mode Valid Receive Counter D Auto Scan Update y Apply 221PM 4 Figure 2 4 LCD Controller Advanced tab 5 Verify that LCD Master in the Port Owner frame is the port owner this is the default value Note Figure 2 4 also shows the other default comm values Baud Rate Parity Data Bits Stop Bits and LCD Mode for the FB107 6 Click Apply if you changed any values on this screen ROCLINK 800 performs a warm start and the Touchpad displays the Emerson Process Management logos EMERSON Process Management Touch Screen bo Skart Figure 2 5 Emerson P
14. 6 Display Mode cours 1 4 ESA Disertante nme re ey 3 6 Bee e EE 1 5 PP tint 3 1 Segel le EE 2 6 3 11 Issued Sep 07 Index FB107 LCD User Manual Biet EEN 3 5 TransreflectiVe oococococococococononononononononononononononono 1 3 U WSCC Die e a eo 2 11 User list leien Eet 3 11 Senn A ee eek 3 11 Belg 3 10 WISER LISTS lt a 2 11 3 10 Usmo the Touchp d DEE 3 1 V NM SPIN ATION aiii 3 22 Viewing Dynamic Gate eenn 3 28 HistoncalGharlS s serae ia ed cds 3 27 W Warm Starless 3 36 l 3 FB107 LCD User Manual If you have comments or questions regarding this manual please direct them to your local sales representative or contact Emerson Process Management Remote Automation Solutions a Marshalltown lA 50158 U S A Houston TX 77065 U S A i Pickering North Yorkshire UK Y018 7JA EMERSON Website www EmersonProcess com Remote LA Index Issued Sep 07
15. Form Number A6241 Part Number D301258X012 September 2007 FloBoss 107 Flow Manager LCD User Manual Remote Automation Solutions EMERSON FloBoss 107 Flow Manager LCD Program User Manual Revision Tracking Sheet September 2007 This manual may be revised periodically to incorporate new or updated information The revision date of each page appears at the bottom of the page opposite the page number A change in revision date to any page also changes the date of the manual that appears on the front cover Listed below is the revision date of each page if applicable Page Revision Initial issue Sep 07 NOTICE Remote Automation Solutions RAS division of Emerson Process Management shall not be liable for technical or editorial errors in this manual or omissions from this manual RAS MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND IN NO EVENT SHALL RAS BE LIABLE FOR ANY INCIDENTAL PUNITIVE SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PRODUCTION LOSS OF PROFITS LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL FUEL AND POWER AND CLAIMS OF THIRD PARTIES Bristol Inc Bristol Babcock Ltd Bristol Canada BBI SA de CV and the Flow Computer Division are wholly owned subsidiaries of Emerson Electric Co doing business as Remote Automation Solutions
16. Sep 07 Using the Touchpad 3 5 FB107 LCD User Manual 3 2 Logging On In daily operation the Touchpad normally displays the Emerson Process Management logo in its idle or waiting state EMERSON Process Management Touch Screen to Shark Figure 3 10 Idle State Display 1 Touch the screen A second screen displays depending on the mode you ve selected Normal or BLM If you ve configured BLM mode the Touchpad begins to auto scroll through the parameters you defined on ROCLINK 800 s LCD User List BLM screen see Section 2 3 If you ve configured Normal mode the Touchpad displays a log on screen o Enter PIN gt ERE SERED AAA A tie se Figure 3 11 Log On Note The Touchpad displays this log on screen for 60 seconds If you do not enter a PIN in that time the idle state screen displays 2 Enter a valid log on PIN As you touch each number the Key Acknowledgement LED Key Ack Figure 3 should blink green and the Touchpad reverses the numeric image see Figure 3 12 3 6 Using the Touchpad Issued Sep 07 Issued Sep 07 FB107 LCD User Manual EE ESE SES pepe Figure 3 12 Touched Value If you enter an incorrect PIN number the Touchpad displays a message Click OK and re enter the PIN Invalid PIA Figure 3 13 Invalid PIN Message Note The default PIN is 1000 If you have disabled that PIN or replaced it with another PIN to establish security for your F
17. ce end of day processing from the Touchpad 3 36 Using the Touchpad Issued Sep 07 FB107 LCD User Manual 1 Touch End of Day from the System menu The Force End of Day menu displays Force End ot Day Figure 3 75 Force End of Day Menu 2 Touch Yes When the end of day processing completes the Touchpad displays a confirmation message Force End ot Day Complete Figure 3 76 Confirmation Message 3 The Touchpad then displays the System menu 3 8 5 Adjusting Touchpad Contrast Use this option to adjust the displayed brightness of the Touchpad The FB107 stores the contrast value in a section of Flash memory that is protected from firmware upgrades 1 Touch Contrast on the System menu The Contrast Control Parameters screen displays 2 Contrast Control gt SE gt Increase Y Decrease Figure 3 77 Contrast Control Parameters Issued Sep 07 Using the Touchpad 3 37 FB107 LCD User Manual 2 Touch A or Y to increase or decrease the contrast on the Touchpad The current contrast value limited between 110 and 86 displays below the Contrast label Note Above 110 the Touchpad contrast becomes too dark below 86 the contrast is too light 3 Touch Save to place the current contrast setting in protected Flash memory The Touchpad displays a confirmation message Saving Contrast Figure 3 78 Confirmation Message 4 Touch Exit to display the System menu 3 9 Logging Off This option enab
18. de information in a sequence appropriate for first time users Once you become familiar with the device and the procedures the manual becomes a reference tool This manual has the following major sections Chapter I Introduction Chapter 2 Configuration Chapter 3 Using the Touchpad This manual assumes that you are familiar with the FB107 and its configuration For more information refer to the following specification sheet and manuals FloBoss 107 Flow Manager Instruction Manual Form A6206 FloBoss 107 LCD Specification Sheet 5 5 LCD ROCLINK 800 Configuration Software User Manual for FB107 Form A6217 The Touchpad enables you to access FB107 process and operational information and to view and change FB107 parameters The Touchpad is a touch sensitive liquid crystal display LCD screen It fits behind a protective covering that is mounted to an enclosure see Figure 1 1 Introduction 1 1 FB107 LCD User Manual Figure 1 1 FB107 Touchpad Enclosure Mounted Note The Touchpad with FB 107 is designed to be mounted to an enclosure Remote Automation Solutions has an enclosure designed for the Touchpad If you choose to use your own enclosure contact your local sales representative for a template and appropriate specifications The Touchpad communicates with the FB 107 through a dedicated RS 232 connection located on the FB 107 base unit see Figure 1 2 The Touchpad s RS 232 connection is p
19. dialog box you can use to select a valid TLP Sets a 10 character alphanumeric identifier for the data point Shows the engineering units for the associated parameter Indicates whether the system applies automatic or manual value limit factors to the charted results Valid values are Auto apply automatic values or Sets the high value for the data point Note This field is available only if you select Manual as a scaling option Sets the low value for the data point Note This field is available only if you select Manual as a scaling option 3 Click Apply if you make any changes to this screen 4 Click OK to close the LCD User List Chart screen 5 Proceed to Chapter 3 Using the Touchpad Touchpad security enables you to selectively restrict or permit access to Touchpad functions for up to 16 user IDs you define To do this you use ROCLINK 800 s Device Security screens Figures 2 12 and 2 15 You can define an ID which can access all or only one user list or just the Touchpad s standard lists Additionally the ID can have edit capability or just view capability You define IDs and their accesses to meet your organization s needs Configuration 2 9 FB107 LCD User Manual 1 Select ROC gt Security from the ROCLINK 800 Menu bar The Device Security screen displays Device Security a Sie eee ES e TEE EE Disabled fe Ebed Level Enabled Security on COMTI Sri UserID p User Access
20. een in Figure 3 27 or the RTD parameter screen in Figure 3 41 provide Calibrate as an option 2 RTD A EU Ualue Degrees F H Dun Alarms MANUAL Exit Calibrate Figure 3 41 RTD Parameters Note Refer to Chapter 8 Utilities in the ROCLINK 800 Configuration Software User Manual for FloBoss 107 A6217 for a complete SE SE Calibrate For calibration you define a zero point a span and up to three midpoints To calibrate a point 1 Touch Calibrate on the parameter screen The Touchpad displays the Calibrate menu Figure 3 42 Calibrate Menu Note Whether you select Calibrate or Verify ROCLINK 800 freezes the current value and displays a notification screen When you exit the utility ROCLINK 800 restores the live EE 2 Touch Calibrate The Touchpad displays a message screen starting the calibration and freezing the EU value and then displays a parameter screen 3 22 Using the Touchpad Issued Sep 07 FB107 LCD User Manual De 1350 de Gap Cancel Set Zero Figure 3 43 Set Zero Calibration Point Note You can touch the value displayed in the Tester Value field to edit it The FB 107 continues to update the Live Value field and calculate the deviation percentage 3 Touch Set Zero when the displayed values are appropriate The Touchpad prompts you to set a span point Ja Pet Cancel Set Span Figure 3 44 Set Span Calibration Point Note You can touch the value displayed in the Tes
21. efore scrolling to the next parameter set The Touchpad displays up to two parameters at a time Valid values are 0 do not scroll to 255 the default is 4 Note If you set this value to 0 you must use the M and Y keys on the Touchpad to manually scroll through the parameters defined in the list Device Sets the parameter that you want to display on the Parameter Touchpad Click to display a Select TLP screen _ you use to define the parameter Text Setsa10 characteralphanumeric identifier for the ae parameter 5 Click the 17 32 tab to define 16 additional parameters 2 6 Configuration Issued Sep 07 FB107 LCD User Manual 6 Click Apply if you make any changes to this screen 7 Click OK to close the LCD User List BLM screen 8 Proceed to Chapter 3 Using the Touchpad 2 4 Configuring Standard or Normal Mode In Standard or Normal mode the Touchpad displays the Emerson Process Management logos When you touch the screen a logon grid displays You then enter a PIN number to log on to the Touchpad 1 Select the Advanced tab of the LCD Controller screen The Advanced screen displays mam ROCLINK 800 On Line Com1 FB107 File Edit View ROC Configure Meter Utilities Tools Window Help De SB Ske Vl Nas iP s On Line Com FB107 MM Modules CFE PJ SENSOR Not Installed SS LCD Controller Module Information SLOT 0 On Board 6 Point 10 z SLOT 1 RS 485 SLOT 2 Au
22. enu 6 Touch Exit to display the Meter Run menu 3 5 Module Information Issued Sep 07 Use this option to view information for each module installed in the FB107 The Modules menu shows only the modules you have installed on your FB107 For example Figure 3 25 shows a fully equipped FB107 with expansion plate If your FB107 has an open module slot the Touchpad shows the slot number but does not include a module identifier If your FB107 does not have an expansion plate the Touchpad displays the second row slots 4 through 7 but omits the numbers indicating those slots are not available You can also use this menu to display information on meter runs refer to Section 3 5 5 Viewing Meter Information and to diagnose alarm conditions refer to Section 3 5 8 Calibrating a Point Viewing I O and Diagnostic Information 1 Touch Modules on the Main Menu The Modules menu displays SE n Pi SCH Meter SysHi Drs Notes A blinking asterisk in the upper right corner of a module box as in slots O and 3 in Figure 3 25 indicates an integrity or alarm issue in this module This mirrors a blinking asterisk that may appear in the upper right corner of the Modules option on the Main Menu The content of the Modules menu corresponds to your installed system The example in Figure 3 25 shows a fully loaded FB 107 Using the Touchpad 3 15 FB107 LCD User Manual 2 Touch a module The Touchpad displays a screen showing
23. ermanently configured with a baud rate of 19200 1 stop bit 1 start bit 8 data bits and no parity Introduction Issued Sep 07 FB107 LCD User Manual Display connection Figure 1 2 FB107 Base Unit Display Connection The Touchpad is a transreflective LCD To maintain readability in direct sunlight it reflects most of the sunlight and increases or decreases the brightness of its display based on the amount of light This reduces your need to manually adjust the screen It also has a backlight to increase readability during low light use conditions or during critical operations such as when you enter a PIN code During idle periods the backlight automatically enters a power saving mode to conserve energy The Touchpad requires no manual calibration Internal firmware provides the coordinates to assure display communications between the Touchpad and your FB107 Issued Sep 07 Introduction 1 3 FB107 LCD User Manual KEY ACK O O ALARM DOCO731A Figure 1 3 FB107 Touchpad with Open Cover To use the Touchpad you open its protective cover and touch the screen Two light emitting diodes LEDs at the top of the Touchpad provide visual signals on the Touchpad s operational status The green LED indicates successful touches each time you touch the screen the green LED flashes to verify that the Touchpad has acknowledged your entry The green LED also can flash once every three seconds 1f you have set the power savin
24. eter Setup screen Meter gt rs Setup Modules Displays parameter values associated with each 7 mo IAS OG ee Chart Displays historical or dynamic information in a chart format Note These are read only values You define the format scale and content of the charts using the LCD User List Chart screen Configure gt LCD User List gt Chart PID Displays and permits changes to defined PID parameters Note You must first define PID parameters on the PID Loop screen Configure gt Control gt PID es Loop System Enables you to access and modify some general 2 system parameters oo Log Off Logs you off the Touchpad redisplays the idle logo screen Sections 3 3 through 3 9 discuss these options Issued Sep 07 Using the Touchpad 3 9 FB107 LCD User Manual 3 3 User Lists 3 10 User lists are groups of up to 16 system parameters You can define up to four user lists for a total of 64 parameters You first define the user lists in ROCLINK 800 and update your ROCLINK 800 configuration file When you next log onto the Touchpad the User List menu option reflects those changes Alternately you can log off the Touchpad and log back on to see your changes To define user lists 1 Select Configure gt LCD User List gt Standard on the ROCLINK 800 menu bar The LCD User List screen displays LCD User List List No 1 2 3 4 5 E T H 3 E a dd EE Go Mi ei 1 1 1 m OH P Device
25. finished touch Done The Touchpad displays a screen to confirm the new value see Figure 3 5 Change Pid SetPt From bt Bet Toi 242 O68 Figure 3 5 Edited Parameter When you touch Yes the new value appears in the parameter screen s editable field arm 5 List 1 gt HEF Dau 54678 12 Pid 1 SetFt JFM Hold A Figure 3 6 Edited Parameter Note The Touchpad uses this value inside a box signal extensively to indicate a field you can edit Finally you can touch the parameter tag on any parameter screen to display a chart screen that dynamically displays the values of that parameter see Section 3 1 3 3 1 3 Dynamic Charts The Touchpad can display any parameter you select in a dynamic chart recorder format Touch the label or units on a parameter screen to display the chart Charting begins from the moment of touch and continues either for 30 minutes or until you touch Exit Issued Sep 07 Using the Touchpad 3 3 FB107 LCD User Manual Current Current upper and lower scale date and time T6352 Te Figure 3 7 Sample Dynamic Chart The parameter label displays in the upper center of the screen and alternates with a display of the units every four seconds The current parameter value displays in the lower center of the screen The current date appear in the upper right hand corner of the screen The current time appears in the lower right hand corner of the screen The values
26. g the Touchpad 3 29 FB107 LCD User Manual To use this option touch PID on the Main Menu The PID menu displays Et 4 PIO gt Figure 3 59 PID Menu The Basic method accesses a series of parameter screens you use to establish primary and override process variables and setpoints The Advanced method accesses a single graphical screen that use you perform the same tasks 3 7 1 Setting Basic PID Loops Use this option to access a series of parameter screens to establish the PID process variables and setpoints 1 Touch Basic on the PID Menu The PID Loop menu displays Well 166 Well 268 Wel 366 Well 466 Exit PID gt Figure 3 60 PID Loop Menu 2 Touch a PID loop on the PID Loop menu The PID Parameters menu displays Ot PUT it Well 10 gt Figure 3 61 PID Parameters Menu 3 30 Using the Touchpad Issued Sep 07 FB107 LCD User Manual Use these four options Primary Override Mode and Output to refine PID parameters for each defined PID loop You can modify individual parameters or as in this example proceed through each screen in sequence 3 Touch Primary The Primary PID Loop Parameters screen displays 2 Well 16 gt Pri Pl H HAHAH Pri SP H DD Figure 3 62 Primary PID Loop Parameters Use this screen to display the primary process variable and redefine if necessary the primary setpoint 4 Touch Exit to display the PID Parameters menu 5 Touch
27. gs mode see Section 1 2 2 The red LED signals alarm or integrity issues and coordinates with other visual Touchpad clues such as an on screen asterisk 1 or a to identify the area of concern See Chapter 3 Using the Touchpad 1 21 Display Mode The Touchpad has two operational modes Normal and Basic List Mode BLM When you open the cover the Touchpad displays the idle state display typically the Emerson Process Management logo EMERSON Process Management Touch Screen to Shark Figure 1 4 Touchpad Idle State Display 140 Introduction Issued Sep 07 FB107 LCD User Manual When you touch the screen you see either a list of system parameters or a number grid E eee Hold A pr fe 2 a Figure 1 5 Initial Active Touchpad Displays BLM mode indicated by the on screen BLM List label provides an auto scrolling list of read only parameters which displays up to 32 user defined parameters refreshed once per second without requiring a log on process At any time you can interrupt the auto display and log on through the Touchpad Note BLM mode also includes a dynamic chart mode Technicians can touch a parameter and the Touchpad displays a dynamic chart related to that parameter See Chapter 3 Using the Touchpad for further details on this feature Normal mode requires a sign in process before displaying any information Refer to Chapter 3 Using the Touchpad for further informati
28. igure 3 14 provides a map of all Touchpad options Using the Touchpad 3 7 FB107 LCD User Manual Idle State displays Splash Screen 1 Flowing 2 Non Flowing 1 Flow Values Logon 2 Properties Screen 3 Plate Change Valid Logo Main Menu 1 IO Type 2 IO Type 1 User Lists 3 lO Type 4 lO Type 5 IO Type 6 IO Type 1 Calibration 2 Verify 1 Historic 2 Dynamic 3 Extended 1 Hist Pt x 2 Hist Pt x 3 Hist Pt x 4 Hist Pt x 5 Hist Pt x 6 Hist Pt x 7 Hist Pt x 8 Hist Pt x 9 Hist Pt x 10 Hist Pt x 11 Hist Pt x 12 Hist Pt x 13 Hist Pt x 14 Hist Pt x 15 Hist Pt x 16 Hist Pt x 1 Primary 2 Override 3 Mode 4 Output Pri 50 0 1 0 10 0 Auto TE v Figure 3 14 Touchpad Options Map Once you enter a valid PIN on the log on screen the Touchpad s Main Menu screen displays 3 8 Using the Touchpad Issued Sep 07 FB107 LCD User Manual SSES ol Main Menu gt Y Main Mera gt A Figure 3 15 Touchpad Main Menu Option Description User Lists Displays a list of 16 parameter values You can define up to four lists for a total of up to 64 parameters Note Configure these values using the LCD User List screen Meter Runs Displays values for up to four meter runs Note These are read only values You configure the number of valid meters on the Points tab on the Device Information screen ROC gt Device Information and the meter content itself on the M
29. in the upper and lower left hand corners of the screen display the chart s current scale You can modify the scale by touching the asterisk just below the upper scale value The Touchpad displays a numeric keypad you use to define first a new upper range then a new lower range Set Urrer Range Cancel et Lower Range Cancel Figure 3 8 Chart Scale Ranges When you exit the numeric keypads the parameter screen reflects the new values 50 000 T 5352 Figure 3 9 Revised Scales Note These new values are valid only for the current viewing The Touchpad restores the original scale values when you exit the parameter screen 3 4 Using the Touchpad Issued Sep 07 FB107 LCD User Manual 3 1 4 Operational Screens The Touchpad provides a complement of message screens confirmation screens and other screen types to support system processing Refer to Sections 3 2 through 3 9 for examples of these screens 3 1 5 Touchpad Time Out For both security and to save power the Touchpad display goes blank or times out at specific intervals 1f left untouched Touching a timed out screen restores the idle state display see Figure 1 4 from which you must log on again cian Display Duration PIN Figure 3 12 1 minute Menu Figure 3m EE Calibrate Figure 3 43 AAN Plate Change Figure 3 42 e You can also access a power savings mode to enable the Touchpad to time out more frequently see Section 1 2 2 Issued
30. les you to immediately log off the system Touch Log off from the Main Menu The Touchpad immediately displays the idle state screen 3 38 Using the Touchpad Issued Sep 07 Index A ACCESS TE 2 11 Adjusing Touchpad contrast 3 37 Advanced PID LOOPS nnnnnoannnnnneennennennnnnneannnne 3 32 Asterisk DIAG eclesiales 3 1 3 15 B Basic List Mode BLM cccccsseseeeeeseeeeeeeeees 1 5 Basic PID WOODS suas sde 3 30 Blinking asterisk nnnnnnnnaannnnnnneennnnnnnnnnne 3 1 3 15 BLM COMM QUIN Fa idas 2 5 BLM list parameter text cooccconcccooncncanocnncncanecnarinnarionannanno 2 6 Parametros 2 6 EMIS TUG da litis 2 6 A APP 2 4 C Calibre SUS 3 22 GiANGING AUP Ale sas 3 14 Chart Dala SOU Cita tada 2 9 CNA MOJE aa 2 4 Chart Mode A A A 2 8 A O mutans eaten 3 26 Comm Io MalO Mic ad 3 17 Configurations SAVING ccccccccccconcncnnccnnnonanonnnos 3 35 Goniiguring BEM cn acess 2 5 Configuring Chart Mode 2 8 Configuring Normal Mode 2 7 Configuring the Touchpad ccoocooocccnnnccccno 2 1 2 4 Configuring Touchpad Security cocccoonncnncc 2 9 D Daly Usa dae 3 6 Dala DOM cda 2 9 Display SE 1 5 NOMDA UE 1 5 Displaying Meter Parameters 0occccccoocccncccnnoo 3 13 DVS Information cccooccccccoccnncccncnnccnnnnnononinnnnnos 3 21 Dynamic charts ooocccccoccncocnncnnccnnnnnnnnnnnnonnncnnnnnas 3 28 Dynamic Charts oooccccccnccoccnnnncnnnnccnonnonnnnnnnnonnnanos 3 3 E End of Day Proces
31. menu box as in AI 2 and AO 1 in Figure 3 1 indicates an integrity or alarm issue with this point Issued Sep 07 Using the Touchpad 3 1 FB107 LCD User Manual 3 1 2 Parameter Screens Parameter screens primarily display values but provide other ways to display information A label typically appears at the top of a parameter screen indicating where that parameter belongs The bottom of the screen contains two or more boxes usually providing an Exit option on the left hand side a Hold option to prevent the screen from auto scrolling to the next set of parameters in the center and A and Y options on the right hand side so you can move more quickly from parameter to parameter see Figure 3 2 ELM List Flaw List 1 gt j MEF Dau 54678 12 A BG H DD Hold F Figure 3 2 Sample Parameter Screens Up to two parameter values display in the center of the screen The values are dynamic and refresh each second Parameter Parameter tag il or label _ Parameter Parameter units value editable Figure 3 3 Sample Parameter Screen Parameter values are usually read only However you can edit a value in a box as in the case of 534 57 in Figure 3 3 Touch the box to display a numeric keypad screen Figure 3 4 Figure 3 4 Numeric Keypad 3 2 Using the Touchpad Issued Sep 07 FB107 LCD User Manual As you enter a new value the numeric keypad changes as shown in Figure 3 4 When you are
32. ncncnnnanccnnnncnnnnnaancninnnnos 1 6 Chapter 2 Configuration 2 1 2 1 Configuring the Port OWNED cccccccnncccnnnccnnnccccoonncnnnnnononononnnnnnnnnnnnnnnnnnnnnnnnnonnnnrnnnnnnnnnnnannennss 2 1 2 2 Configuring Touchpad COpotons 2 4 2 3 Configuring Basic List Mode DM 2 5 2 4 Configuring Standard or Normal Mode 2 7 2 5 Configuring Chart Mode x ren ina a a iaa aia a iah 2 8 2 6 Goniguring Touchpad Secur E 2 9 Chapter 3 Using The Touchpad 3 1 ail EE Eeer 3 1 Jk EE 3 1 da Parameter SCreenS ensa us eee a ieee a es 3 2 Set G Dynamic CANIS oo coco ecclesia a 3 3 3 1 4 ee Eeer 3 5 3 15 Touchpad Tite lt e sd 3 5 32 iO GOING DN o ee 3 6 39 USE SiS li 3 10 34 Meter RUNS uti ida 3 12 3 4 1 Displaying Meter Ioiormaton AE 3 13 E E ee le Te E RE 3 14 39 Mod le Mlormatl EE 3 15 3 5 1 Viewing I O and Diagnostic Intormaton 3 15 39 2 VIEWING ARTO liegt Cen Ao 3 16 3 5 3 Viewing COMM Information ccccccccconnccnnncccccccconccnnnnnonononanonnnnnnononannnnnnnnnnnnnnnos 3 17 3 5 4 Viewing Multiple Variable Sensor MVS Information o0000nnnnnnnn0annnnnnnneeannnn 3 18 3 5 5 Viewing Meter Jolorratton cocoriiion iii wise add 3 19 3 550 Viewing system Into Mal viii in a 3 20 3 5 7 Viewing Dual Variable Sensor DVS InformationN cccccccccooccnnncnnncccnononan 3 21 30 90 OND atING al e TEEN 3 22 3 0 Gafa e eee oe lo 3 26 30 1 WEWING FUSTONCALDAla EE 3 27 3 6 2 Viewing Dynamic Disraeli 3 28 SEN TEE ee EE 3
33. nitor the relationship between the live and test values touching Verify until you have enough events to ensure verification 3 24 Using the Touchpad Issued Sep 07 FB107 LCD User Manual 4 Touch Done The Touchpad displays a completion message and then displays the Calibrate menu Cal Verify Complete AI Point Normal Figure 3 49 Verification Message Parameters 5 Touch Exit on the Calibrate menu to display the parameter screen from which you began the calibration 2 RID A EU Ualue Degrees F E HEB Alarms MAMUAL Exit Calibrate Figure 3 50 RTD Parameters Issued Sep 07 Using the Touchpad 3 25 FB107 LCD User Manual 3 6 Charts LCD User List Chart Data Source Standard History Y Standard History Y Standard History Standard History Standard History 10 Standard History 11 Standard History gt 12 Standard History gt 13 Standard History 14 Standard History 15 Standard History 16 Standard History if 2 A 4 5 E H H 3 Use this option to display historic or dynamic FB 107 information in a chart format You must first use the ROCLINK 800 LCD User List Chart screen Configure gt LCD User List gt Chart to define up to 16 points for charting see Figure 3 51 Data Point Text Units E Update v ok Figure 3 51 LCD User List Chart Scaling Auto Manual High Scale Ze a e 3 a a e au a o au a o Ze Low Scale e
34. nu The System AI menu displays cout chara rate Exit lt System HI gt Figure 3 38 System AI Menu 2 Touch an option A parameters screen displays 3 20 Using the Touchpad Issued Sep 07 FB107 LCD User Manual 2 Brg Temp gt EU Ualue BS 24 SHE MOME Figure 3 39 System Al Parameters 3 Touch Y or to view additional parameter values 4 Touch Exit to display the System AI menu 5 Touch Exit to display the Modules menu 3 5 7 Viewing Dual Variable Sensor DVS Information Use the Dvs option on the Modules menu to view the following differential or static pressure information Differential Pressure DP Static Pressure SP Current Pressure Current Pressure Alarms Alarms Low Pressure Low Pressure High Pressure High Pressure A D Counts A D Counts 1 Touch Dvs on the Modules menu The DVS menu displays Figure 3 40 DVS Menu Note A blinking i ia or a in the upper right corner of a run box indicates an integrity or alarm issue Touch an option A parameters screen displays Touch Y or to view additional parameter values Touch Exit to display the DVS menu Ye O Touch Exit to display the Modules menu Issued Sep 07 Using the Touchpad 3 21 FB107 LCD User Manual 3 5 8 Calibrating a Point In the process of troubleshooting an integrity error you might find it necessary to calibrate or verify a point Various screens such as the Al parameter scr
35. o display the Touchpad Main Menu You can define up to four meter runs for the FB107 You configure the number of valid meters on the Points tab on the Device Information screen ROC gt Device Information and the meter information itself on the Meter Setup screen Meter gt Setup Once you have defined and configured the meter runs using ROCLINK 800 you can use the Touchpad to view and change the information Touch Meter Runs on the Main Menu The Meter Run menu displays Using the Touchpad Issued Sep 07 FB107 LCD User Manual Exit lt Meter Eun gt Figure 3 20 Meter Run Menu 2 Touch a meter run An option screen displays Note that the selected meter displays at the bottom of the screen Exit lt Well 166 gt Figure 3 21 Meter Menu Note In this example Well 100 is defined as using an orifice meter The Plate Chg option displays only for orifice meters For turbine meters you see only the Values option 3 4 1 Displaying Meter Information Use this option to display meter information 1 Touch Values on the Meter Run menu The meter specific parameters screen displays E lt Well 168 gt INHZA H ABER H ARB SP PSIG Figure 3 22 Meter Parameters 2 Touch Y or to scroll through a number of meter specific parameters including Differential pressure orifice meters only Uncorrected flow turbine meters only Issued Sep 07 Using the Touchpad 3 13 FB107 LCD User Man
36. odule I O Points 3 Touch RTD A parameter screen for the RTD module displays 2 RTD A EU Ualue Degrees F H BREE Alarms MANUAL Exit Calibrate Figure 3 30 RTD Parameters 4 Touch Y or to view additional RTD parameter values 5 Touch Exit to display the Module I O Points screen 6 Touch Exit to display the Module menu 3 5 3 Viewing COMM Information Your FB107 can have up to two communications modules RS 232 or RS 485 which you must place in slots 1 or 2 Use this procedure to verify the status of these modules 1 Touch Modules on the Main Menu The Modules menu displays Issued Sep 07 Using the Touchpad 3 17 FB107 LCD User Manual os 1 2 Pol rege T5455 Exit Meter Zwei Ove Figure 3 31 Modules Menu 2 Touch rs232 or rs485 depending on which communications module you have installed A status screen displays Slot 2 pedes Status Good Figure 3 32 Communication Status 3 Touch OK to display the Modules menu 3 5 4 Viewing Multiple Variable Sensor MVS Information The FB107 supports up to six MVS transmitters Use this option to review the parameters for each transmitter 1 Touch Modules on the Main Menu The Modules menu displays ep 1 2 E rece 1I5dos Exit Meter Zwei Ove Figure 3 33 Modules Menu 2 Touch Mvs The MVS menu displays 3 18 Using the Touchpad Issued Sep 07 FB107 LCD User Manual La 1 is 1 Huve 2 Mu Huyz 4 mes mes Exit lt
37. on 1 22 Power Savings Mode The Touchpad also provides an optional power savings mode which activates whenever the idle state display occurs This power savings mode works with either Normal or BLM display mode Select this option on the Advanced tab of the LCD Controller screen see Figure 1l 6 Issued Sep 07 Introduction 1 5 1 6 FB107 LCD User Manual ROCLINK 800 On Line Com1 FB107 File Edit View ROC Configure Meter Utilities Tools Window Help Den SSSA Ce Whew MES 24OOR HR zw On Line Com FB107 MI Modules s Li amp Control KN Meter 1 Ma System History User Program User Display General LCD Advanced 9600 e 192K C 384K C 576K Baud Rate p Parity e None C Even C Odd RE RE Valid Receive Counter H 07273 4 Data Bits LS 8 Stop Bits Port Owner e 1 LS LCD Master AE A x LCD Mode Normal C ROC Modbus Slave C BLM Power Savings Mode C Normal Low Power Auto Scan Update Figure l 6 Power Savings Modes When you click Low Power and then click Update to apply the change ROCLINK 800 performs a warm start and shuts down the Touchpad While the Touchpad is blank the green LED blinks once every three seconds to indicate the Touchpad is active The Touchpad awakens when you touch it and shows the idle state display At that point log on and proceed to use the Touchpad n
38. on You can touch We or to display additional menu options 2 Touch a selection on the Dynamic Data menu A dynamic charting screen displays Using the Touchpad Issued Sep 07 FB107 LCD User Manual 00 001 PL ONE E jH 50 000 12 34 56 Figure 3 57 Dynamic Chart Each chart can display up to 54 most recent data values The Touchpad alternates the chart header here FLOWHR with the EU value MCF 1f units are available The asterisk on the screen indicates that you can set the upper and lower scale values for the display 3 Touch the asterisk to set new upper and lower scale values The Touchpad displays two screens in sequence Set Urrer Range Lower Range Cancel 3 7 PID Loops Issued Sep 07 Figure 3 58 Upper and Lower Scale Ranges 4 Use each screen to enter a new upper and new lower range for the display if necessary The Dynamic Chart displays 5 Touch Exit to display the Dynamic Data menu 6 Touch Exit to display the Chart menu 7 Touch Exit to display the Modules menu This option provides two methods basic and advanced for displaying and changing Proportional Integral and Derivative PID loops You can define up to eight PID loops on an FB107 Note Use the Points tab on the ROCLINK 800 Device Information screen ROC gt Information to define the total number of active PID loops use the PID Loop screen Configure gt Control gt PID Loop to initially define the PID loops Usin
39. oooocccccccccccnonncnnnnnns 3 4 3 9 Revised Gcales ioagheninnian 3 4 3 10 Idle State Display occccciooomoconoccom o 3 6 SS OO Media ando 3 6 3 12 Touched Value n onennnenoannnnesennnnneennnne 3 7 3 13 Invalid PINMessage ooccccccccccccocccccccccno 3 7 3 14 Touchpad Options Map 3 8 3 15 Touchpad Main Menu 3 9 3 16 LCD User Litio ia 3 10 3 17 User List Men 3 11 3 18 User List Harameierg 3 12 3 19 NumenchRevpad 3 12 3 20 Meter Run Men 3 13 3 21 Meter Menu coooccccccccnccccncononcnnncncnnnnnnnas 3 13 3 22 Meter Harameierg 3 13 3 23 Plate Change Men 3 14 3 24 Plate Change barameiers 3 14 3 25 Modules Men 3 15 3 26 Modules I O Ponts 3 16 3 27 VO Point barameiers 3 16 l 1 3 28 Modules Menu 3 17 3 29 Module l O bont 3 17 3 30 RID Parameters cooocccccnnccnnoconcncnnanonnos 3 17 3 31 Modules Menu 3 18 3 32 Communication Status 00000o000n 3 18 3 33 Modules Menu 3 18 3 34 MVS Menu 3 19 3 35 MVS Parametere 3 19 3 36 Meter Run Men 3 19 3 37 Meter Run Harametere 3 20 3 38 System Al Men 3 20 3 39 System Al Paramters aannnnnn0annnnaaan 3 21 3 40 DVS Men neinn anin 3 21 3 41 RTD Parameters ccoocccccnnccnnononcncnnanonoos 3 22 4 42 Calibrate Men 3 22 3 43 Set Zerol Calibration Point 3 23 3 44 Set Span Calibration Point 3 23 3 45 Set Midpoint 1 Calibration Point 3 23 3 46 RTD Parameters
40. ormally Whenever the Touchpad times out and would normally show the idle state display the Touchpad is blank This reduces the energy required to continually show the idle state display 1 2 3 Touchpad and ROCLINK 800 Security ROCLINK 800 security enables you can determine which user IDs can access which Touchpad features You can define up to 16 user IDs each of which can have read only read write or no access to the four user lists and standard features of the Touchpad See Section 2 6 Configuring Touchpad Security Introduction Issued Sep 07 FB107 LCD User Manual Chapter 2 Configuration This chapter provides instructions for configuring Touchpad options The FB 107 is factory configured to accept the Touchpad Until you connect the Touchpad to the FB 107 the Display port displays an integrity red I error see Figure 2 1 Section 2 1 After connecting the Touchpad you can configure additional display options as well as Touchpad security see Sections 2 2 through 2 6 2 1 Configuring the Port Owner 1 Log onto and open ROCLINK 800 The FB107 graphic displays a ROCLINK 800 On Line Com1 FB107 Sele File Edit View ROC Configure Meter Utilities Tools Window Help Dep es Asp S24 OUR HR Ze On Line Com FB107 MM Modules e we 1 0 gt e a amp Control cs Meter Ma System History User Program User Display Gener vanced 140 Points Meter Points
41. ph also moves indicating which value you can now change The upper right corner of the display indicates whether the Touchpad is displaying information from the PID loop s Primary or Override control loop Touch this field to switch between the loops This is an option only if you have selected Override Control as the Control Type on the General tab on the PID Loop screen in ROCLINK 800 An asterisk in the upper left corner of the graphic indicates whether the selected loop is in control Touch Exit to display the PID Loop menu Touch Exit to display the PID menu Using the Touchpad 3 33 FB107 LCD User Manual 3 8 System Information This option enables you to view a variety of system information adjust system parameters and perform common tasks System Information Saving a configuration Perform a warm start Forcing end of day processing Adjust Touchpad contrast To use this option touch System on the Main Menu The System menu displays Exit d System gt Y Figure 3 68 System Menu Each of these options 1s discussed in detail below 3 8 1 Displaying System Information Use this option to display pertinent system information including 3 34 Time and date ROC Name Firmware revision LCD revision Device address Device group Contract Hour CPU Load Touch Info on the System menu The System Parameters screen displays Using the Touchpad Issued Sep 07 FB107 LCD User Manual 2 Sytem
42. r Access Disabled Enabled Level Enabled Figure 2 14 Device Security 5 Repeat steps 2 and 3 to add up to 14 more IDs 6 Click OK to display the FB107 graphic 2 12 Configuration Issued Sep 07 FB107 LCD User Manual Chapter 3 Using The Touchpad This chapter describes the day to day use of the Touchpad 3 1 Touchpad Screens The Touchpad uses several major screen formats to present information Included are menu screens parameter screens and dynamic charts Note System security settings controls which options display on your Touchpad and whether you can edit parameter values Refer to Section 2 6 Configuring Touchpad Security for further information 3 1 1 Menu Screens Menu screens are basically two or more options placed in a grid Typically an Exit option may appear in the menu s lower left corner A menu label such as Main Menu or Slot 0 in Figure 3 1 is centered between brackets and arrows to access additional menu options may appear in the right corner of the menu Figure 3 1 shows two examples of menu screens Main Menu gt Y Figure 3 1 Sample Menu Screens Touching an option on the menu screen s grid may lead to another menu or to a parameter screen Notes A blinking asterisk in the upper right corner of a menu box as in the Modules option in Figure 3 1 indicates an integrity or alarm issue in this module A blinking i ia or a in the upper right corner of a
43. rocess Management Logos Proceed to Sections 2 2 through 2 6 to configure display options Issued Sep 07 Configuration 2 3 FB107 LCD User Manual 2 2 Configuring Touchpad Options When configuring Touchpad options you determine both the default display mode Sections 2 3 through 2 5 and which user IDs may access which Touchpad features Section 2 6 You use the Configure option on the ROCLINK menu bar to select one of two possible default display modes for the Touchpad file Edit View ROC Meis Meter Utilities Tools Window Help Chart ih Eg e LD One Coen EE 3 Mi Modules History Points a mt LIT Opcode Table amp Control MODBUS A E Meter De LCDUser List Mia System User Data History User Program Standard BLM Figure 2 6 ROCLINK 800 LCD User List Configuration Options Option Standard Description Requires you to first log onto the Touchpad Displays based on pre defined ROCLINK 800 security parameters select system values and allows you modify select system parameters Note This is also called Normal mode BLM Automatically displays up to 32 parameter values Allows you based on pre defined ROCLINK 800 security parameters to log onto the Touchpad and display select system values and modify select system parameters Chart 2 4 Configuration Requires you to first log onto the Touchpad Displays in a chart recorder format his
44. rt allow you to scroll forward gt or backward Ca on the historical record up to 60 days 3 2 Issued Sep 07 Using the Touchpad FB107 LCD User Manual 3 0 2 3 28 as defined on the ROCLINK 800 History Setup screen s Setup tab Touch an arrow once to move in daily or hourly steps touch and hold an arrow to fast scroll through the chart The date for the current scroll point appears in the upper right hand corner of the screen The time for the current scroll point appears in the lower right hand corner of the screen The value for the current scroll point appears in the lower middle of the screen The label for the value appears in the upper middle of the screen and alternates with the units for that label every four seconds Touch Exit to display the Daily History menu Touch Exit to display the History menu Touch Exit to display the Chart menu ae St SS Touch Exit to display the Modules menu Viewing Dynamic Data Use this option to view dynamic data points you have defined on the LCD User List Chart screen 1 Touch Dynamic on the Chart menu The Dynamic Data menu Zan displays Exit lt Dynamic gt Y Figure 3 56 Dynamic Data Menu Note The titles on the Dynamic Data menu items correspond to what you have used or entered in the Text field on the LCD User List Chart screen You can define as many as 16 Dynamic points The Touchpad configures each defined point as a menu opti
45. s Mode 100 15 indicator Loop control _ gt indicator i Py bh 8 PV bar d well 100 gt graph Output bar graph 3 4 Figure 3 67 Graphical PID Loop This display provides a dashboard view of the selected PID loop The left vertical bar graph represents the output value for the PID loop the right bar graph represents the process variable value for the loop Units for each bar graph display at the top of each graph The upper and lower EU values for each bar graph display at the top and bottom of the graph This is a dynamic display as the output or PV values change the graphic changes Touch the Output or PV vertical bar graph to access charts that display these values Touch A or Y to modify the output or setpoint depending on the PID loop s current mode Auto or Manual indicated by the boxed value in the upper right corner of the display If the PID mode is Manual the buttons change the output parameter If the PID mode is Automatic the buttons change the PID setpoint Touch and release a button to change the value by one percent touch and hold the button down to more quickly change the value To change the PID mode from Auto to Manual or Manual to Auto touch and hold down the Auto Man value for two seconds The green Key Acknowledgement light blinks indicating that the value has changed This two second touch prevents you from accidentally changing the PID mode The indicator arrow on the bar gra
46. sing cccoccncccncccnccnoncnnnnnannnnnas 3 36 Issued Sep 07 FB107 LCD User Manual F Figures 1 1 FB107 Touchpad Enclosure Mounted 1 2 1 2 FB107 Base Unit Display Connection 1 3 1 9 FD VOT TOUCKDAG risas 1 4 1 4 Touchpad Idle State Display 1 4 1 5 Initial Active Touchpad Displays 1 5 1 6 Initial Active Touchpad Displays 1 6 2 1 FB107 Graphic Display ooo occoo o 2 1 2 2 Touchpad ActivatiON oooncccccccccnnnncnnnno 2 2 Re eine 2 2 2 4 LCD Controller Advanced tab 2 3 2 5 Emerson Process Management Logos 2 3 2 6 RL800 LCD User List Configuration Options ade patente 2 4 2 7 RL800 LCD User List Configuration Options nod 2 5 2 8 LCD User List BIM 2 6 2 9 RL800 LCD User List Configuration Options Advanced ab 2 7 2 10 Touchpad Main Men 2 8 2 11 LCD User List Chart 2 8 2 12 Device Security ooooonnccnncccccconccnnnnonnos 2 10 2 13 Device Security User Level 2 11 2 14 Device Security ooooonccccnccccccocccnnnnnnnos 2 12 3 1 Sample Menu ScreenS oooccnccccccccocnccnnnnns 3 1 3 2 Sample Parameter Screens n0000nn 3 2 3 3 Sample Parameter anoaannnnnno0aannnnnenneanni 3 2 3 4 Numenchevpad 3 2 3 5 Edited Parameter noannnnnennnnnnennnnenennnne 3 3 3 6 Edited Harameier 3 3 3 7 Sample Dynamic Chart seseeeeeeeeeeeee 3 4 3 8 Chart Scale Ranges o
47. tarts 3 10 LOGOING Ocio 3 38 LOW Cal ET 2 9 M Menu Map 3 8 Menu SCIONS cccccccccecececececcceccuecececenenenenenenecs 3 1 Meter Info DISPla Ida iaa 3 13 Meter Intormaton 3 19 Meter Plates OMAN GING atada da 3 14 Meter RUN Sutra ned stent uta det o 3 12 Module Information asasanennannnnennnnnnnnnnnnnnnnnnnnna 3 15 MVS Informal ii eee 3 18 N Normal Display Mode 00ooccccccccccccoocccconncccnnoancnnno 1 5 Normal Mode COMMUNI Usera 2 7 O Operator Droit 2 11 edel EE EE 3 8 Orifice Meters Changing a Plate 00aannnnnnnnaaaannnnnneaaannnnnn 3 14 Overview Hardware 1 1 SOMWANC anida 1 1 P Parameter screens ccececececccccccececeneceaeaeaeaenes 3 2 Parameter evt 2 6 3 11 Parameters US A A A A 3 13 E EE 2 11 PUD Lee 3 29 3 37 e VT er EE 3 32 O A ena een 3 30 Power Savings mode 1 5 R ALO HATO Vd Le EEN 3 16 S Saving configurations occccccccconnnnnccconnnnnnnnnns 3 35 ee le WE 2 9 SCOPE Organtzaion 1 1 Screens Dynamic GAINS tias 3 3 A ones an cme cence 3 1 3 3 Mscellaneous 3 5 A ee dee eet 3 2 Cro Ie gt eee nee en ii iii 2 6 3 11 Issued Sep 07 AU eeh 1 6 Configuring E 2 9 Software A sateen be 1 1 Standard LASS cuina cial 2 11 Standard Mode dadas 2 4 System Information oaannnaannnneeannnnnnaana 3 20 3 34 T A eene 3 5 Title A O aN 2 6 A E 3 10 Touchpad COMMUNICATIONS iia 1 2 SONITONO 2 1 COMM QUINN G oa 2 4 COMMAS Causa teens 3 37 Daly US Grona 3 1 3
48. ter Value field to edit it The FB107 continues to update the Live Value field and calculate the deviation percentage 4 Touch Set Span when the displayed values are appropriate The Touchpad prompts you to set the first of three calibration midpoints An PA Cancel Set Midi Done Figure 3 45 Set Midpoint I Calibration Point Note For calibrations you can set up to three midpoints the Touchpad presents a screen on which you can set each midpoint or none at all by touching Done You can also touch Cancel at any time to cancel the calibration Issued Sep 07 Using the Touchpad 3 23 FB107 LCD User Manual 5 When you touch Done the Touchpad evaluates the calibration displays a completion message indicating whether the calibration was successful and displays the Calibrate menu 6 Touch Exit to display the parameter screen from which you began the calibration d FETO A EU Ualue Degrees F E Hp Alarms MANLIAL Exit Calibrate Figure 3 46 RTD Parameters Verify To verify a point 1 Touch Verify on the Calibrate menu The Touchpad first displays a message screen Starting the verification and freezing the EU value and then displays a parameter screen 46 BEBE H HHAH Figure 3 47 RTD Verification Parameters 2 Touch Verify The Touchpad displays a message and generates an event for the event log Werification Evert Generated Figure 3 48 Verification Message Parameters 3 Mo
49. torical or dynamic values for up to 16 user defined parameters Note For convenience a dynamic charting function is available for the parameters displayed in basic list mode However this is not the full function charting facility Issued Sep 07 FB107 LCD User Manual 2 3 Configuring Basic List Mode BLM In Basic List Mode BLM the Touchpad displays up to 32 parameter values automatically scrolling through the list at a speed you define The Touchpad displays up to two parameters per screen This mode allows service technicians to quickly review a dynamic display of current values without logging onto the Touchpad 1 Select the Advanced tab of the LCD Controller screen The Advanced screen displays ven ROCLINK 800 On Line Com1 FB107 Eile Edit View ROC Configure Meter Utilities Tools Window Help Aw S 4ORR WH 3 e Cah MI Modules a ZS CPU a B wie a On Line Com FB107 gt SENSOR Not Installed SS LCD Controller Module Information SLOT 0 On Board 6 Point IO SLOT 1 RS 485 SLOT 2 Auxiliary 6 Point 10 SLOT 3 MVS Module Module Information M S1 MVS 1 P MVS2 MVS 2 MVS3 MYS 3 MYSA MVS 4 MVS5 MVS 5 MYSG MVS 6 SLOT 4 Auxiliary 6 Point IO 1 Bn SLOT 5 Auxiliary 6 Point IO SLOT 6 Auxiliary 6 Point IO 5 SLOT 7 Not Installed Ma 1 0 amp Control KW Meier GC Ms System History EZ User Program E User
50. ual Static pressure Temperature Flowrate Energy rate Flow today Energy today Alarms 3 Touch Exit to display the Meter Run menu 3 4 2 Changing a Plate Although you can also accomplish this process using the Plate Change screen in ROCLINK 800 Meter gt Plate Change the Touchpad provides this function as a convenience for service technicians who may need to change orifice plates without access to ROCLINK 800 1 Touch Plate Chg on the Meter Run menu The Plate Change Menu displays Exit lt Well 16 gt Figure 3 23 Plate Change Menu 2 Touch the condition under which the plate change occurs Note If you select Flowing the system freezes input values for the duration of the change to provide constant values to the flow calculations and displays a notification screen When you exit this activity the system restores the meter values 3 The system then displays three parameter values screens lt Well 168 gt np lt Well 164 gt lt Well 168 gt Pipe Di TP ease a B7106 HzO 125 9888 hoa F 75 0597 EE Aziak PSIG oo SARE Figure 3 24 Plate Change Parameters 3 14 Using the Touchpad Issued Sep 07 FB107 LCD User Manual Note You can edit the orifice diameter value These parameter screens remain active for 30 minutes after which the Touchpad displays the idle state screen 4 Touch Exit to display the Plate Change menu screen 5 Touch Exit to display the Meter m
51. values 1 Select Configure gt LCD User List gt Chart from the ROCLINK 800 Menu bar The LCD User List Chart screen displays LCD User List Chart Scaling Data Source Data Point Text Units Auto Manual High Scale Low Scale Dynamic sl CLK TIME im fe e faro Standard History zl Undefined f Standard History Undefined f Standard History Undefined ff Standard History v Undefined f Standard History Y Undefined wf iY 2 Update Y 0 X Cancel Figure 2 11 LCD User List Chart LD Oo mM om WwW ra 5 nu a a e a l L me we FP e ee gw RK KKK e cm e TTA ETT an Apply 2 8 Configuration Issued Sep 07 2 6 Configuring Touchpad Security Issued Sep 07 FB107 LCD User Manual 2 Complete the following fields to define the chart display values Field Data Source Data Point Text Units Scaling HighScale Low Scale Description Sets the source for data included in the chart Valid values are Standard Sets a standard history point to History chart Click to open a Select History Point dialog box you can use to select a valid standard history point Extended Sets an extended history point to History chart Click to open a Select History Point dialog box you can use to select a valid extended history Dynamic Sets a dynamic data point to chart Click to open a Select TLP
52. word associated with this ID Confirm Confirms the four digit password associated with Password this ID Note The contents of this field must match the contents of the Password field Access Level This field does not apply to the FB107 Touchpad User List 1 Indicates whether the ID can access the user through 4 defined User Lists Valid values are Disabled Removes the user list from the displayed options View Only Displays the user list but does not allow edits to displayed data View Edit Displays the user list and allows edits to displayed data Standard Lists Indicates whether the ID can access the standard Touchpad functions that is the options on the Main Menu screen Meter Runs Modules Charts PID System and Log Off Valid values are Disabled Removes the user list from the displayed options View Only Displays the user list but does not allow edits to displayed data View Edit Displays the user list and allows edits to displayed data Issued Sep 07 iaa 2 FB107 LCD User Manual 4 Click OK to apply these edits The system displays the updated Device Security screen Device Security Secunty on LOI g Use ID User Access EE dl EE Security op COM p Use ID User Access P Disabled Enabled Level Enabled Security on COM Sr UserID User Access fee E EE Security on COMMS en UserID lUser ccesz Disabled C Enabled Level Enabled Secunty on LEO Sri UserID Use
53. xiliary 6 Point 10 SLOT 3 MVS Module 1 W s SLOT 4 Auxiliary 6 Point 10 SLOT 5 Auxiliary 6 Point 10 Ba SLOT 6 Auxiliary 6 Point 10 EJ SLOT 7 Not Installed Se 1 0 E amp Control E Meter a System History User Program E User Display m Baud Rate 9600 192K C 34K C 576K Valid Receive Counter fi 78063 Parity r Data Bits4 r Stop Bits Ze None C Even C Odd LS e 8 e 1 LS Port Owner LCD Mode POOR HF 2 2N LCD Master Normal C ROC Modbus Slave C BLM Power Savings Mode C Normal Low Power Auto Scan Update IENNE osa 7 Figure 2 9 ROCLINK 800 LCD User List Configuration Options Advanced tab 2 Verify that Normal is selected in the LCD Mode frame This is the factory default value for the Touchpad 3 Click Apply if you have needed to change the setting ROCLINK 800 performs a warm start The Touchpad now starts in Normal mode Issued Sep 07 Configuration 2 FB107 LCD User Manual 4 Proceed to Chapter 3 Using the Touchpad 2 5 Configuring Chart Mode Chart mode allows the Touchpad to emulate a chart recorder After you log on normally Chart is one of the options displayed on the Main Menu Main Meru gt Y Figure 2 10 Touchpad Main Menu The Touchpad can display up to 16 historic or dynamic system values Use this procedure to define the displayed
54. y changes to this screen To define additional lists repeat step 2 4 Click OK to close the LCD User List screen Once you have defined your user lists and sent the changes to the Touchpad you can view them on the Touchpad and if appropriate edit the values Note These steps assume you have successfully logged onto the Touchpad and are starting at the Main Menu 1 Touch User Lists on the Touchpad The User List menu displays Exit x User List gt Figure 3 17 User List Menu 2 Touch the number of a User List A parameters screen displays FB107 LCD User Manual 3 4 Meter Runs 3 12 MTS LS Flow os HCF Day 24678 L Figure 3 18 User List Parameters 3 The Touchpad automatically scrolls through the defined values in the user list You can touch Hold to pause the display and restart the scroll by pressing Scroll or touch Y or to move more quickly through the parameter values In this example note that the value for the second parameter Pid 1 SetPt has a box around it This means you can edit it If you touch this value a numeric keypad screen displays Cancel Figure 3 19 Numeric Keypad If appropriate use the keypad to enter a new value for the indicated field Touch Done to apply the edited value to the parameters screen The Touchpad requires your confirmation before it applies any changes to the parameter values 4 Touch Exit to display the User List menu 5 Touch Exit t
Download Pdf Manuals
Related Search
Related Contents
Sony VAIO SVE1512GCX 452313 Mode d`emploi pour le masque en car- ton "Afrique 3" CONTENIDO Abre-puerta de garaje serie PREMIUM Kettler ERGORACE 07988-880 User's Manual AlphaEclipse™ 2500/2600 Sign Installation Manual Manual de Notificaciones UAF - Superintendencia de Bancos y Initial Setup ARCMASTER® Manual de operación 300 AC/DC STIPalm User Manual Copyright © All rights reserved.