Home

Quick Installation Guide

image

Contents

1. Step1 Fasten all connectors securely together Step2 Tightly wrap two layers of self bonding insulating tape forward and backward over the physical connection extending 2 inches beyond the connectors or the end of heat shrinkable tubing on the RF coaxial cable or omni antenna connector and overlapping the tape on each turn Room 313 3F Bldg 52 No 195 Chung Hsing Road Sec 4 Chutung Hsin Chu Taiwan 310 Tel 886 3 5822911 Fax 866 3 5822311
2. Please refer to the user manual for detailed description of each selection item Configuring AP with console Alternatively Aphelion AP can be configured via console and serial port on your PC 1 Connect power supply to PoE injector with the AC power cord provided and connect Aphelion AP to POWER amp DATA OUT port on the PoE with MIL C 5015 IP67 Cat 5 Ethernet Cable provided as shown in the connection diagram Both POWER and ACTI VE LED on the PoE will be on when Aphelion AP is properly powered on 2 Connect the AP and the PC with MIL C 5015 IP67 RS 232 Console Cable with 115200bps connector the black color RS232 connector provided Adjust the baud rate of your terminal software to 115200bps 128kbps Set the flow control to N A Connect the AP from terminal software Enter the default password 0000 and press ENTER on your keyboard to enter the main menu of SMT If the connection is correct the main menu of Aphelion system menu tree SMT will appear on your terminal software A A a a Outdoor Installation Mounting Kits Waterproof Installation Aphelion Aphelion Communications Inc Most of the problems of outdoor models are from the connector connections that loosen over time due to vibration or other forces even allowing moisture to penetrate the connector and seriously affecting the data and radio signal transmit The following recommendation is used for all outdoor installation to be waterproofed
3. of Aphelion AP is 192 168 1 1 so the PC needs to be set in the same net scope to access AP with Telnet 1 Go to Control Panel of your PC and double click Network Connections icon 2 Right click Local Area Connection and select Properties 3 Select TCP IP for the applicable Ethernet adapter and click Properties 4 Click the IP Address tab page select USE the following IP address type an address between 192 168 1 2 to 192 168 1 254 192 168 1 1 is for the AP for I P Address and 255 255 255 0 for Subnet Mask then click OK button STEP 3 Connect the AP by telnet After having the correct connection start the telnet session to 192 168 1 1 Enter the default password OOOO and press ENTER on your keyboard to enter the main menu Aphelion system menu tree SMT will appear on your terminal software as shown below Aphelion Communications Inc Aphelion 668 Hain Henu General Configuration system Hanagenent 11 8ustem General Setup 31 Configuration Hanagement 12 Interface Configuration 32 Security File Hanagement 13 Assign WAH Interface 433 Firmvare Upgrade 14 Routing Configuration 34 8ustem reboot Advanced setting System Monitoring 2i System Password 41 Interface Link Status 22 Bandwidth Control 42 Connecting Client List 23 DHCP Configuration 43 ustem log 24 NAT Configuration 44 8ustem Information 2J SH AF Configuration 45 Command Line 6 Wireless Security Setting 99 Logout Enter Henu Selection Humber
4. Aphelion Outdoor Access Point Series 500AG 600AG 3300AG Quick Installation Guide Package Contents Aphelion 500AG 600AG 3300AG 802 11a b g Outdoor Wireless Access Point unit PoE Power Injector AC Power Cord 30m MIL C 5015 IP67 Cat 5 Ethernet Cable 2m MIL C 5015 IP67 RS 232 Console Cable Grounding Wire Wall Mounting Kit amp Screw Mast Mounting Kit amp Screw Quick Installation Guide 10 CD User Manual Please contact your local distributor reseller if any of the above items is missing SS at a SS eS IY a Basic Connection Antenna 1 Antenna 2 i MIL C 5015 IP67 Cat 5 Ethernet Cable Console Ethernet Cable AP Configuration with SMT User Interface Configuring AP with Telnet STEP 1 Power on Aphelion AP 1 Connect power supply to PoE injector with the AC power cord provided as shown in the above diagram The yellow POWER LED on the PoE will be on when the PoE has adequate power supply 2 Connect Aphelion AP to POWER amp DATA OUT port on the PoE with MIL C 5015 IP67 Cat 5 Ethernet Cable provided The red ACTIVE LED indicates if the AP has successfully powered on 3 Connect DATA IN port on the PoE injector with Ethernet cable to the LAN that the AP associates with STEP 2 Verify IP address setting Configure the network settings on your PC to obtain an IP address Computer uses IP addresses to communicate with each other across a network such as a LAN The default I P address

Download Pdf Manuals

image

Related Search

Related Contents

report - Distributed Computing Group  COMPACT 1.4 - Dirna Bergstrom  notes techniques : retrait/installation de portière  Operating instructions Mode d`emploi Manual de instrucciones    Boyo - Vision Tech America VTL426 Automobile Electronics User Manual    Mini Stage Lighting User Manual Unboxing check Thank you for  Dataram 2 GB DDR3 DIMM  Massive Ceiling light 30244/48/10  

Copyright © All rights reserved.
Failed to retrieve file