Home

SCENA LED 80 FR User manual rel 1.2 Eng

image

Contents

1. o1 143 1 SYMBOLS Graphic symbols used on this manual abr LED 130 cmf Dx 2 GENERAL WARNING THIS SYMBOL INDICATES A HOT SURFACE THIS SYMBOL INDICATES ELECTRIC SHOCK RISK THIS SYMBOL INDICATES GENERAL RISK THIS SYMBOL MEANS YOU CAN PLACE THE UNIT ON NORMALLY FLAMMABLE SURFACES THIS SYMBOL INDICATES THE MINIMUM DISTANCE TO BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT THIS SYMBOL INDICATES THE EUROPEAN COMMUNITY DIRECTIVE 2002 96 EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE Read the instruction contained in this user manual carefully as they give important information regarding safety during installation use and maintenance The device is not for domestic use and must be installed by a qualified electrician or experienced person Always disconnect the device from the mains before maintenance The device must always be equipped with an efficient ground connection 3 GENERAL WARRANTY CONDITIONS The unit is guaranteed for 36 months from the date of purchase against manufacturing material defects 4 TECHNICAL FEATURES OVERVIEW SCENA LED 80 FR is a compact lightweight DMX controlled projector featuring a single high power LED and a wide excursion zoom enabling it to be used as a Beam or a very wide Wash SCENA LED 80 FR is a modern alternative to conventional lights improving light quality flexibility of use and installation energy savings and component duration In fact th
2. 000255 __ Proportional dimmer 16 The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein MADE IN ITALY The Lighting Company ISO 9001 2008 D T S quality system is certified to the ISO 9001 2008 standard D T S products are designed and manufactured at the D T S 05171243 D T S Illuminazione s r l Via Fagnano Selve 10 12 14 47843 Misano Adriatico RN Italia Tel 39 0541 611131 Fax 39 0541 611111 info dts lighting it www dts lighting it
3. J T S Illuminazione s r l ITALY http www dts lighting it The Lighting Company Made in Italy Le informazioni contenute in questo documento sono state attentamente redatte e controllate Tuttavia non e assunta alcuna responsabilita per eventuali inesattezze Tutti i diritti sono riservati e questo documento non pu essere copiato fotocopiato riprodotto per intero o in parte senza previo consenso scritto della D T S D T S si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche funzionali o di design a ciascun proprio prodotto D T S non assume alcuna responsabilit sull uso o sull applicazione dei prodotti o dei circuiti descritti The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein Les informations contenues dans le present manuel ont t r dig es et control es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles inexactitudes Tous droits r serv s Ce document ne peut tre cop
4. DMX Driver for the D T S RED BOX interface D T S Firmware upgrade utility program installed on PC Latest firmware release available for SCENA COMPACT LED 50 unit Updating the software version Please follow the procedure below to perform the update 1 Install the D T S RED BOX USB DMX driver on the PC you will use to update the unit software 2 Connect the D T S RED BOX interface to the PC by using a USB cable 3 Connect the D T S RED BOX interface to the fixture by using a DMX cable 4 Send the new software version into the unit by using D T S Firmware upgrade Utility program 10 DISPLAY FUNCTIONS DFP Digital Function Panel DISPLAY FUNCTIONS The SCENA LED 80 display panel shows all the available functions Using these functions it is possible to change some of the parameters and add some functions Changing the D T S setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it Carefully follow the instructions below before carrying out any variations or selections NOTE the symbol 0 shows which key has to be pushed to obtain the desired function Software version 1 07 IS IS J MO E Up Down LI ENTER Up Down ES Ss REVERSE DISPLAY Reverses display s reading depending on the mounting position on the ground or suspended DISPLAY STAND BY To turn off the display after 5 seconds Or leave it alw
5. ammable materials surfaces greater than 200 C with some combustion time lag Minimum distance from the closest illuminable surface 30 cm LED 030 Replace any blown or damaged fuses only with those of identical value 2AT 6 2 Prevention from electric shock High voltage is present inside the unit Unplug the unit prior to performing any operation which involves touching the inside of the unit This equipment must be grounded do not connect to non grounded supplies The use of a thermal magnetic circuit breaker is recommended for each SCENA LED 80 unit Use only AC supplies 90 260V 50 60 Hz SCENA LED 80 should never be located in position exposed to rain or in areas of extreme humidity A good air ventilation is essential for proper equipment work 6 3 Safety The external surface of the unit may exeed 50 C never handle the unit until at least s AN minutes have elapsed since the unit was turned off Never install the unit in an enclosed area lacking sufficient air flow The ambient temperature should not exeed 40 C and should not be lower than 10 C 6 4 Waste Electrical and Electronic equipment WEEE directive nio The unit accessories and packaging should be sorted for environmetal friendly recycling For EC countries according to the European Directive 2002 96 EC for Waste Electrical and Electronic Equipment and its implementation into national right luminaires that are no longer usable must be collected separ
6. ately and disposed of in an environmentally correct manner 7 INPUT OUTPUT CONNECTIONS E DISPLAY PANEL EC n 4000 K DMX IN XLR 5 Pins Male Panel Connector DMX OUT XLR 5 Pins Female Panel Connector MAINS AC INPUT 90 260V 50 60 Hz SERIAL pom MAINS AC OUTPUT 90 260V 50 60 Hz M Max 30 units 230Vac Max 15 units O 110Vac FUSE 2AT 8 DMX SIGNAL CONNECTION The unit operates using a digital DMX 512 signal Connection between the controller and the unit or between units must be carried out using a two pair screened 0 5 mm Ensure that the conductors do not touch each other Do not connect the cable ground to the DMX connector chassis The plug housing must be isolated Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first unit to the DMX IN plug of the second one In this way all the projectors are cascade connected CONTROLLER STANDARD DMX 512 a 1 GND Pe 2 DATA NS gt 32 DATA 3 DMX IN DMX IN DMX IN I i DMX OUT DMX OUT i DMX OUT DMX OUT If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX terminator is a male XLR 3 5 pins connector with a 120 oh
7. ays on WS MENU Up Down DMX MODE To select DMX mode 2 DMX channels mode default 1 DMX channel mode 3 DMX channels mode or Manual mode Manual mode can also be activated by pressing at the same time the DOWN buttons on unit display for 3 seconds 001 E 4 m 4 m ay 4 SI Up Down m Floor IS Position Oo NI suspended Position SP Displa SP IT CIE Alwayson SY Always on ENTER Default DMX Mode 2 Channels 1 DMX channel mode 3 DMX channels mode LS Manual Mode I L1 4 ENTER 11 D D I dL d ps pe MENU Up Down IL 11 ENTER Up Down LED ST Led Min Max Smooth Compression Default 0 ENTER Default 100 JS Sync and Boost level values settings Off o E xm LED MINIMUM VALUE Quadratic This menu allows to select the gt nil minimum levels for white Hp Denn ae emm output ee LED MAXIMUM VALUE Linear Linear page This menu allows to select the UE maximum levels for white Range SU TS 610 Hz 10KH ISP TM Up Down ENTER Up Down ENTER These settings have priority Default 610 Hz on Master Dimmer channel ini IS S IS i SS SMOOTH VALUE This menu allows to select the value of DOSSI Hiec Ds the delay in milliseconds for Dimmer PUR channel reaction to DMX or Program variation With BOOST active the LED S Off 25 ms Instant response to DMX curr
8. e fixture doesn t heat up and the projection is always flicker free Also the dimming curves are similar to those of halogen lamps PRODUCT CODES 03 15031 46 F SCENA LED 80 FR WHITE 3000K Black finish 03 15032 46 F SCENA LED 80 FR WHITE 4000K Black finish 03 15033 46 F SCENA LED 80 FR WHITE 5000K Black finish LED Technology 1 x White LED 3000K 7700 Im CRI gt 90 4000K and 5000K also available 2700K 5600K or 6500K on request Optical group 112mm Fresnel lens 14 77 linear zoom Control 2 DMX channels default 4 digit 7 segments display 4 soft keys Connection Power supply POWERCON In Out panel connectors DMX XLR 5 poles In Out panel connectors Power supply Electronic full range AC 90 260V 50 60 Hz Consumption 80W Max Weight 3 Kg DIMENSIONS 190 5 223 5 185 5 ACCESSORIES As standard 1 x User s Manual 1 x POWERCON male cable connector D T S Code 0520P014 1 x XLR 5 pins male cable connector D T S Code 0508B028 1 x XLR 5 pins female cable connector D T S Code 0508B027 1 x Filterframe for SCENA COMPACT Black finish D T S Code 02M00422 46 Optional on request C Clamp G60 Max Load 50 Kg Black finish D T S Code 0521A004 Barndoor for SCENA COMPACT Black finish D T S Code 03 TA206 6 IMPORTANT SAFETY INFORMATION 6 1 Fire prevention It is permissible to place the unit on normally flammable surfaces Suitable for mounting on normally fl
9. ent is set to Max value variation 30 more gain compared to 20 250 ms Smooth response to DMX BOOST Off variation Default Disabled COMPRESSION This menu allows to select between Linear current output or Quadratic current output for LEDs Default Quadratic SYNC This menu allows to adjust the PWM frequency value Hz in order to reduce flickering in the process of your camera recordings BOOST DRIVING This menu allow to increase the LED s current from Min to Max DIMMER Dimmer intensity level range 0 255 Active only if MODE 1 DMX channel mode Note i Ss del E 5 3 NER External infrared remote sensor needed D T S Code 03 LA 016 INFRARED MODE ai Infrared remote control By activating Ir Mode it will be possible to navigate trought the unit functions by using the D T S NOT IMPLEMENTED ON SCENA LED 80 infrared remote control D T S Code 0514L008 12 pap Wireless LE OFF Ss 097 ES E ILL UN ES Enabled WIRELESS DMX Wireless on Disabled Wireless DMX enabled disabled By activating WDMX MODE it will be Gata IS UNLINK LOGOUT possible to control SCENA LED 80 via D T S ANTENNA Wireless DMX Transmitter cod 03 E1271 Active only on SCENA LED 80 with Wireless on board Logging on SCENA LED 80 WIRELESS DMX must be enabled on SCENA LED 80 unit Ci nal LOI Hai I SEL iS ES is To log on the SCENA LED 80 in the WIRELESS system simply press and quickly release the
10. function button on the transmitter The transmitter will start flashing rapidly red green scanning for new free receivers SCENA LED 80 units When a SCENA LED 80 logs on to the transmitter the LINK green light on transmitter starts to flash rapidly After approximately 10 seconds the transmitter will jump back to normal mode and continue transmitting data The SCENA LED 80 now try to synchronize to the transmitter When synchronized to the transmitter 2 different modes are possible 1 Antenna transmitter has detected and transmits a DMX signal in this mode a solid green light is seen on the transmitter and solid display is seen on SCENA LED 80 2 No DMX signal connected the Antenna transmitter will flash red green display blinking on SCENA LED 80 To log SCENA LED 80 off from a transmitter simply select UNLINK function LINL ui under WIRELESS DMX MENU Lidi TH and press ENTER When SCENA LED 80 is logged off the display is blinking meaning its available for log in on a new transmitter Logging out a SCENA LED 80 Select UNLINK function Uni H under WIRELESS DMX MENU Lid TH and press ENTER When SCENA LED 80 is logged off the display is blinking meaning its available for log in on a new transmitter Logging out all SCENA LED 80 units linked to a transmitter Press and hold the function button of the transmitter for about 3 seconds When the display is blinking on SCENA LED 80 it mean that the units are logged out Transmi
11. ie photocopi ou reproduit dans sa totalit ou partiellement sans le consentement pr alable de D T S D T S se r serve le droit d apporter toutes modifications et am liorations esth tiques fonctionnelles ou de design sans pr avis a chacun de ses produits D T S d cline toute responsabilit sur l utilisation ou sur l application des produits ou des circuits d crits Las informaciones contenidas en este documento han sido cuidadosamente redactadas y controladas Con todo no se asume ninguna responsabilidad por eventuales inexactitudes Todos los derechos han sido reservados y este documento no puede ser copiado fotocopiado o reproducido total o parcialmente sin previa autorizaci n escrita de D T S D T S se reserva el derecho a aportar sin previo aviso cambios y modificaciones de car cter est tico funcional o de diseno a cada producto suyo D T S no se asume responsabilidad de ning n tipo sobre la utilizaci n o sobre la aplicaci n de los productos o de los circuitos descritos 1 SYMBOLS 2 GENERAL WARNING 3 GENERAL WARRANTY CONDITION 4 TECHNICAL FEATURES 5 ACCESSORIES 6 IMPORTANT SAFETY INFORMATION 6 1 Fire prevention 6 2 Prevention of electric shock 6 3 Safety 6 4 Waste Electrical and Electronic Equipment WEEE directive 7 INPUT OUTPUT CONNECTIONS 8 DMX SIGNAL CONNECTION 8 1 DMX Addresses 8 2 Selecting the DMX address 9 FIRMWARE UPDATING 10 DISPLAY FUNCTIONS 11 DMX PROTOCOL SJ
12. m resistor Between pin 2 and 3 The DMX terminator must be plugged into the last unit DMX out panel connector of the DMX line PLACE A 120 OHM RESISTOR BETWEEN PIN 2 AND 3 OF A MALE XRL CONNECTOR AND PLUG IT INTO THE DMX OUT PANEL CONNECTOR OF THE PIN 3 LAST UNIT CONNECTED TO THE DMX LINE 120 PIN 2 8 1 DMX addresses SCENA LED 80 FR can be controlled with 2 DMX channels default 3 DMX channels or 1 DMX channel In order to use the unit in 2 DMX channels mode set the following addresses on the mixer Projector 1 001 Projector 2 A003 If you want to select the next projector just add 2 Projector 3 005 projector A011 8 2 Selecting the DMX address 1 Press the UP DOWN key until you reach the required DMX address The numbers on the display will start to flash but the new DMX address hasn t yet been set 2 Press ENTER to confirm your selection The numbers on the display will stop flashing and the projector is now controlled by the new DMX address TIPS if you keep pushed the UP or DOWN keys the channels are calculated more quickly and you get a faster selection 2 Press ENTER to confirm your selection The numbers on the display will stop flashing and the projector is now controlled by the new DMX address 9 FIRMWARE UPDATING To update the software version of the SCENA LED 80 you need D T S RED BOX interface D T S Code 03 LA 008 USB
13. s 150 179 Pulse down from 42 6 s to 120 ms AN 180 204 Dimmer channel active Dimmer channel disabled 230255 DMX CHANNEL 2 Parameter DIMMER DMX range Mid Point Move Range Function Value DMX degrees value 000255 E __ Proportional dimmer 1 CHANNEL MODE 1 DIMMER DMX CHANNEL 1 Parameter DIMMER DMX range Mid Point Move Range Function Value DMX degrees value 000255 J _ Proportional dimmer 15 3 CHANNELS MODE 1 SHUTTER STROBE 2 DIMMER 3 DIMMER FINE DMX CHANNEL 1 Parameter SHUTTER STROBE DMX range Mid Point Move Range Function Value DMX degrees value 000 00 OO Blackout 010 019 020020 SOS 030119 ___ Strobe from 3 27 s to 30 ms 120 1490 Pulse up from 42 6 s to 120 ms 150179 _ down from 42 6 s to 120 ms 0 lt lt 180 204 Dimmer channel active A Dimmer channel disabled 230 255 DMX CHANNEL 2 Parameter DIMMER DMX range Mid Point Move Range Function Value DMX degrees value 000255 O Proportional dimmer DMX CHANNEL 3 Parameter DIMMER FINE DMX range Mid Point Move Range Function Value DMX degrees value
14. tter Status LED Flashing red green no dmx connected Solid green dmx signal detected and transmitted Fast flashing red green log in mode every free SCENA LED 80 unit not logged in to any other transmitter will be logged on SCENA LED 80 Status Display blinking not logged on to a transmitter free Solid display logged on to a transmitter and receiving dmx data MENU Up Down ES UN Down EMERGENCY Emergency operating mode By setting Emergency mode it will be possible to select Dimmer intensity level that will then ran if DMX signal is missing or not available Usefull for Emergency EXIT illumination on public areas DEFAULT SETTING To restore default settings Lomo MENU Up Down Lee ENTER TEMPERATURE LED Driver board and LED temperature monitoring LIFE TIME This menu show the total unit life time and the LED life time SOFTWARE Software version 3 Default OFF ES 057 Down ENTER Default 204 80 14 11 DMX PROTOCOL 2 CHANNELS MODE Default 1 SHUTTER STROBE 2 DIMMER DMX CHANNEL 1 Parameter SHUTTER STROBE DMX range Mid Point Move Range Function Value DMX degrees value 000 00 J lack out 010 019 md 9w V 020020 9 Blackout 030119 po Strobe from 3 27 s to 30 ms 1200149 _ _ up from 42 6 s to 120 m

Download Pdf Manuals

image

Related Search

Related Contents

HP 12H User's Manual  POSI Modele - AVS - Automatik Ventiler System AS    Instruction for use Mode d`emploi EN FR Lubricating  (2001年)8月1日(PDF形式:4393KB)  Kenwood KRC-152LG Cassette Player User Manual  LBH-1790A,1795A BETRIEBSANLEITUNG  MANUEL D`UTILISATION LIT ALDRYS`EVOLUTION  Cuanbo HDMI 1:4 Splitter User Manual  