1. LO O oe This product can work with up to 3 sensors at any one time to capture temperature and relative humidity readings in various locations around the home Acomplete set of 3 sensors are provided in this package while replacement wireless remote sensors can be purchased separately THGR122N This sensor conveniently displays the temperature humidity which makes it especially suited for locations where you would like to see this data at a glance without having to refer each time to the main unit such as children s room 12 6 15 F4F2 31 LCD display LED status indicator Wall mount hole RESET CHANNEL switch Battery compartment Or OR Ge JN THGN132N LED status indicator Wall mount hole Battery compartment RESET hole CHANNEL switch RAR5S01_IM_EN_R4 indd 4 DP ONS ACCESSORIES SEPARATE PURCHASE REQUIRED Optional wireless remote sensors such as those listed below can be purchased separately For more information please contact your local retailer THGR122N THGN122N THGN132N Features and accessories will not be available in all countries GETTING STARTED esta SENSOR INSTALLATION Step applicable only to THGR122N Using a Philips screwdriver open the battery compartment cover 2 Slide channel switch to select channel 1 Ensure you use a different channel for the other sensors 2 3 3 Insert the
2. ZZ a on Multi zone weather station Specifications Precautions Model RAR501 RAA501H About Oregon Scientific sssssssssssssececeeseeeseessssceeee 8 EU Declaration of conformity c cccceseeeeeseeee 9 USER MANUAL FCC statement INDEX Overview Front view Back VSW cecrus aaisa 3 SONSON erea eee N ER 3 Accessories separate purchase required 4 Getting started Remote sensor installation Mainiuinitiinstallationy iaa 5 Synchronising and placing Sensors 00e 5 Nametags nant aerae dena Steed Resa 6 Weather forecast s nnnsusenernnrnrenrnrnnrerennnrnnrnrnnnnnne 6 Temperature and humidity ccscceseceeseeseeeneeee 6 Mold alert oceanerne aoei 6 MPOUDIGSMOOUING 22 252 45 5553 052s toesseeshe ee cdedi cette 6 ROS Aa E E arannionnecticaiecnmeasend 7 RAR501_IM_EN_R4 indd 1 12 6 15 F F2 30 ZS O M 1 Weather forecast 2 Q mold alert 3 Main unit batteries low 4 Temperature and humidity for location where main unit is placed 5 Temperature and humidity for location where sensor is placed 6 Customisable name tags AUW N RAR5S01_IM_EN_R4 indd 2 L 12 6 15 F4F2 31 BACK VIEW Wall mount hole Battery compartment Collapsible table stand C F select temperature unit RESET reset unit to default settings oF Oy RAR5S01_IM_EN_R4 indd 3 a
3. 1 5V battery without battery RAR501_IM_EN_R4 indd 7 12 6 15 FF2 31 zZ wW PRECAUTIONS Do not subject the unit to excessive force shock dust temperature or humidity Do not cover the ventilation holes with any items such as newspapers curtains etc Do not immerse the unit in water If you spill liquid over it dry it immediately with a soft lint free cloth Do not clean the unit with abrasive or corrosive materials Do not tamper with the unit s internal components This invalidates the warranty Only use fresh batteries Do not mix new and old batteries Images shown in this manual may differ from the actual display When disposing of this product ensure it is collected separately for special treatment and not as normal household waste Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible Consult the furniture manufacturer s care instructions for information The contents of this manual may not be reproduced without the permission of the manufacturer RAR501_IM_EN_R4 indd 8 e Do not dispose old batteries as unsorted municipal waste Collection of such waste separately for special treatment is necessary e Please note that some units are equipped with a battery safety strip Remove the strip from the battery compartment before first use e Should there be any discrepancy between the
4. English and other language versions the English version shall apply and prevail NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice NOTE Features and accessories will not be available in all countries For more information please contact your local retailer ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products If you re in the US and would like to contact our Customer Care department directly please visit https us oregonscientific com service support asp For international inquiries please visit https us oregonscientific com about international asp 12 6 15 F F2 31 EU DECLARATION OF CONFORMITY Hereby Oregon Scientific declares that this Multi zone weather station Model RAR501 RAA501H is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service E CEL O Rons COUNTRIES RTTE APPROVAL COMPLIED All EU Countries Switzerland CH and Norway D RAR501_IM_EN_R4 indd 9 FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any in
5. batteries matching the polarities 4 Press RESET after each battery change 5 Replace the battery compartment cover 12 6 15 F4F2 31 lt p 1 2 Remove the battery compartment Insert the batteries matching the polarities 3 Press RESET after each battery change The battery icon E may appear in the following areas AREA MEANING Main unit Main unit batteries low environment area Remote sensor Remote sensor batteries environment area low NOTE We recommend that you use alkaline batteries with this product for longer usage and lithium batteries in temperatures below freezing Batteries should not be exposed to excessive heat such as sunshine or fire The main unit will automatically search for new sensor reset within the last 30 minutes If unit failed to synchronise with remote sensor reset both the main unit and sensor or try selecting a different channel and press RESET RAR5S01_IM_EN_R4 indd 5 i p U A The remote sensor reception icons will show the following status ICONS MEANING 1 1 Main unit is searching z gt P for sensor s z A sensor has been E gt gt found and logged on B andi No sensor found Place the remote sensor within 30 m 98 ft from the main unit TIP When placing sensors remember the intended location for each sensor Refer to channel switch position 1 2 3 and match with
6. channel icon 7 5 Lt displayed directly above name tag The transmission range may vary depending on many factors You may need to experiment with various locations to get the best results For best results Place the sensor out of direct sunlight and moisture Position the sensor so that it faces the main unit minimizing obstructions such as doors walls and furniture 12 6 15 F4F2 31 z W hE O oe z w s e Place the sensor in a location with a clear view to TEMPERATURE AND HUMIDITY the sky away from metallic electronic objects To toggle temperature unit e Using a thin blunt instrument press C F to toggle 5 F s between C F Name tags can be inserted in the main unit see front view diagram There are 3 blank name tags provided in this package You can write on the blank tags the name of the locations This product features moisture alert function to inform where the sensors are being installed users that there is a high risk of mold forming and should therefore take preventive measures WEATHER FORECAST The mold alert icon amp will flash when humidity is 60 This product forecasts the next 12 to 24 hours of weather or above and will stop flashing when the humidity falls forecast within a 30 50 km 19 31 mile radius below 60 D Weather forecast area p ICON DESCRIPTION DISPLAY AREA PROBLEM Sunn y LL L Temperature Reading
7. is below LL Humidity range Partly cloudy HH H Temperature Reading is above Cloudy HH Humidity range Sensor is not w or 9 Temperature logged or does Rainy and Humidity not have humidity function Snowy RAR501_IM_EN_R4 indd 6 12 6 15 F4F2 31 RESET Using a thin blunt instrument press RESET to return to default settings SPECIFICATIONS TYPE DESCRIPTION 134 x 27 x 134 mm ELNAN 5 3 x 1 1 x 5 3 in Weight 240 g 8 46 oz without battery Signal frequency 433 MHz RAR501 315 MHz RAA501H Temperature range 5 C to 50 C 23 F to 122 F Humidity range 25 95 4 x UM 4 AAA 1 5 V Eo O M E z W Signal frequency 433 MHz RAR501 315 MHz RAA501H Number of channels 3 Transmission range 30 m 100 ft unobstructed Temperature range 20 C to 60 C 4 F to 140 F Humidity range 25 95 Power 2 x UM 4 AAA 1 5 V DESCRIPTION 4 96 x 50 x 22 mm battery TYPE LXWXH 3 8 x 1 9 x 0 9 in Weight 50 g 1 76 oz without battery 433 MHz RAR501 Power batteries Signal frequency 315 MHz RAA501H Number of channels 3 Transmission range 30 m 100 ft unobstructed TYPE DESCRIPTION Temperature range 20 C to 60 C eer 92 x 60 x 20 mm 4 F to 140 F 3 6 x 2 4 x 0 79 in Humidity range 25 95 60 g 2 11 oz Weight 9 Power 1 x UM 3 AA
8. terference received including interference that may cause undesired operation WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 12 6 15 F4F2 31 ZS O M e Reorient or relocate the receiving antenna is in conformity with Part 15 of the FCC Rules Increase the separation between the equipment and Operation is subject to the following two conditions 1 receiver This device may not cause harmful interference 2 This device must accept any interference received including Connect the equipment Iniovan outlet On A circuit interference
9. that may cause undesired operation different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales Please call our customer service number listed on our website at www oregonscientific com or on the warranty card for this product for all gt inquiries instead A We Name Oregon Scientific Inc Address 19861 SW 95 Ave Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 declare that the product Product No RARS01 RAASO1H Product Name Multi zone weather station Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong 10 RAR501_IM_EN_R4 indd 10 uP 12 6 15 F4F2 31