Home

914 Detector Users Manual PTI - Photon Technology International

image

Contents

1. mode is made by a separate control box The 914 has been configured for your application and the PMT is already installed There are no user serviceable parts in the circuit board housing of the 914 914 Photomultiplier Detection System 2 Specifications PMT type Power supply requirements Analog Mode HV adjustment range Shortest response time Internal electronic signal amplification Electronic amplification linear bandwidth Internal electronic signal amplification at 100 MHz Electrical coupling Bandwidth set by jumpers at the factory Photon Counting Mode Maximum count rate Absolute linear count rate Linear count rate 5 deviation Pulse pair resolution Output pulses Output pulse width Typical PMT Spectral Response any 28 mm diameter side on tube 15V 50mA 15V 150mA 0 1250 V 100 ns X100 0 2 MHz X1 DC 10 kHz 30 MHz or 200 MHz 10 million 3 million 7 million 60ns TTL 10 40 ns Model R928 R509 R1527 Range 185 900 nm Peak 400 nm 330 nm 340 nm 185 870 nm eso mi 10 Photon Technology International Overall and mounting holes dimensions all dimensions in inches t 4 900 Inputs and Outputs Input Power Power and control 9 pin CPC circular plastic connector Output Digital Digital signal BNC Analog Analog signal BNC 914 Photomultiplier Detection System 11 2 Service The 914 has been configure
2. nor will PTI provide training on its use free of charge 6 Photon Technology International Safety Symbols Used In This Manual NOTE Not all may be present in this manual This symbol indicates the potential for serious bodily harm Extreme care should be taken when performing the task and all warnings should be strictly adhered to All possible DANGER steps should be taken to ensure safety This symbol represents the potential for electrical shock and or other bodily harm Care should be taken when performing the task There is also the potential for damage to WARNING equipment if warnings are not taken seriously This symbol represents the potential for equipment damage The user is expected to use care when performing the task CAUTION This symbol represents the risk of UV radiation User must take all appropriate steps to protect eyes and exposed areas of the skin RADIATION 914 Photomultiplier Detection System 7 Table of Contents Trademark and Proprietary Information ccsccssccccssssssscscsssssscccsssssssssscees 4 PTI Standard Instrument Warranty scccssssscccssssssssccssssssscccssssssssssessssscssees 5 Safety Symbols Used In This Manual ccssssscccssssssccsssssssccscssssssccsssssssscesseees 6 Table of II A 7 LO inmi 8 AAPEA AN a ka nee oo ba koke k en Snr mon bek 9 Overall and mounting holes dimensions ooocmommsscscssss 10 Inputs and OufpNfS ainia 10 A A ae
3. 11 Replacing the photomultiplier TODE siissisisssisisssnasissctseescacsnsexasessdenssiseasnseeisrernasastonsansaiensiinnabs 11 3 servia Calls to PL ae k k k kk 13 8 Photon Technology International 1 Introduction Congratulations on purchasing your new photomultiplier detection system from Photon Technology International This instrument was designed and built by PTI to offer you the highest quality possible The PTI Model 914 photomultiplier detection system is a combined digital photon counting and analog detection system consisting of an integrated photomultiplier tube PMT housing that includes high voltage supply controls and signal processing circuitry Various tubes are available to suit a variety of detection needs and are easily installed within minutes The 914 accepts 28 mm 1 inch diameter side on PMTs Digital photon counting mode is selected by a TTL low signal on the Analog Digital select line This is the default mode The PMT digital high voltage is factory set No external control is reguired for digital mode Analog mode is set by applying a TTL high signal 3 5 to 5 V on the Analog Digital select line The PMT analog high voltage is controlled by a 0 to 5 V input on the High Voltage control line corresponding to 0 to 1250 V on the PMT Overall control of the 914 housing settings is via the computer An optional manual switching between analog and digital modes and adjustment of the PMT high voltage in analog
4. anty 13 Warranty is valid only in the state province or country of the original purchase 14 Warranty is valid only on systems having a computer supplied by PTI 15 Software upgrades performed on the PTI computer workstation e g adding word processors image editors etc not authorized by PTI will void the warranty 16 Hardware upgrades performed on the PTI computer workstation e g adding network boards sound cards etc not authorized by PTI will void the warranty Warranty Returns A Return Material Authorization RMA Number must be obtained from the PTI Service Department before any items can be shipped to the factory Returned goods will not be accepted without an RMA Number Customer will bear all shipping charges for warranty repairs All goods returned to the factory for warranty repair should be properly packed to avoid damage and clearly marked with the RMA Number Warranty Repairs Warranty repairs will be done either at the customer s site or at the PTI plant at our option All service rendered by PTI will be performed in a professional manner by qualified personnel Software PTI makes no warranties regarding either the satisfactory performance of the software or the fitness of the software for any specific purpose PTI shall not be responsible for any liability loss or damages caused or alleged to be caused by our software as a result of its use including without limitation consequential damages and loss of profit
5. d for your application There are no user serviceable parts in the circuit board housing of the 914 High voltage is present inside the housing Replacing the photomultiplier tube To avoid possible damage to the sensitive photomultiplier tube it is suggested that the new PMT be kept in darkness as much as possible until it is installed in its socket and the housing is closed Be careful not to touch the photocathode area of the PMT UV glass envelope Finger oils may deposit on the surface and these may emit fluorescence when illuminated by incident light If you do touch the PMT envelope wipe the glass clean with a lint free tissue dampened with methanol and then with a clean dry tissue When removing or installing the PMT carefully grasp the base of the PMT with thumb and index finger and pull down or push up on the PMT while gently moving it side to side by small angles Do not move the PMT through large angles as you can crack the ceramic insulator base of the PMT socket You will need 2 5 mm and 7 64 inch hex keys Allen wrench ball end preferred 1 Exit FelixGX if it is open 2 Turn off the power on the ASOC 10 box 3 Disconnect all cables from the 914 housing 4 Dim or turn off the room lights An unpowered PMT exposed to bright light can have a high dark count that may take several minutes to hours to dissipate 5 Use a 2 5 mm hex key to remove the four screws mounting the 914 flange to the slit assembly and pull t
6. eee Ii a a G D G OO DO ee DNA HE A TIRA O O E A or E A ee ee ae eee ee ee ee ee eee ee ee ee ee eee eee ee ee eee eee o e EOS SIA ww Eee SEA ee eee eae MM eee ee oe ee eee ee ie ee B M O E O O re O O O O A Y A A O NM am PA gt D ue ee ee a yA cs AUT D Cl a ee ee E ee DE SS _ E ee ee ee ee ee ee ee ee ee eee Se E EE mr IO ee NIM ee e a ee ee ee ee eee ee eee ee ee eee ee eee _ oe oe aes mu Q _ e _ O O aes y Photon Tec hnology Internat ional A _ NI a i ME nm NI a G P O ODD OD DON DPDJN NIN ONA RAJ Oe TIRA ae eee eee eee A ee eee ee eee ee eee ee ee eee eee A a E AEO ae eee ee ee ee ee ee ee eee ee eee eee ee ee eee eee o e meee eee eee ee eae eee A M Ee SEE A aoe ee eee ee ae ee NN m MU M O A O re re O O O O A Y A A O NM p PON D D on E ona a ee EMA DP DR ee eee eee eee ee eee E ae eee eee eee eee O O a oa Ee OS LX TT IO 1 e eee ee e ee ee o AOM eee ee ee ee DD NENA MAM z es my O Photon Technology International Copyright O 2010 PTI All Rights Reserved PTI is a registered trademark of Photon Technology International Inc 300 Birmingham Road P O Box 272 Birmingham NJ 08011 Phone 609 894 4420 Fax 609 894 1579 Website www pti nj com Specifications and contents are subject to change without notice 4 P
7. he 914 housing away from slit assembly 6 Use a 7 64 inch hex key to remove the three screws mounting the PMT housing to the circuit board housing 7 Pull the PMT housing away from the PMT and the circuit board housing 8 Using your thumb and index finger grasp the base of the PMT and rock it slightly side to side while pulling the PMT out of the socket Wrap the PMT in bubble wrap then place it in a box 9 Remove the new PMT from its packaging The rib on the indexing pin is on the same side of the PMT as the photocathode so that when the rib inserts into the notch in the socket base the photocathode faces the back of the housing 1 e toward the incident light Using your 12 10 11 12 13 14 Photon Technology International thumb and index finger grasp the base of the PMT and rock it slightly side to side while pushing the PMT into the socket Make sure the PMT is fully seated in the socket Slide the PMT housing over the PMT so that the flange side is aligned with the PMT photocathode Le the flange is opposite from the connectors on the circuit board housing Use the 7 64 inch hex key to insert and tighten the three screws to mount the PMT housing to the circuit board housing If the O ring falls out of the PMT housing or housing flange put it back in place If it will not stay in place in the recessed groove around the light hole use your fingertip to moisten the side of the O ring that sits in the gro
8. hoton Technology International Trademark and Proprietary Information ALI materials on this document including but not limited to text images and illustrations collectively the Materials are owned or controlled by PTI Trademarks apply The materials contained in this document are subject to change without notice PTI makes no warranty of any kind with regard to this material and shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishings performance or use of this material You may not copy reproduce republish upload post transmit or distribute the materials in any way whatsoever without prior written approval from authorized personnel of Photon Technology International PTI and the PTI logo are registered trademarks of Photon Technology International Inc The following product names are all trademarks of PTI Brytebox DeltaScan DeltaRAM FeliXTM FeliX32TM FelixGXTM Filter Scan ImageMasterTM ImageMaster Pro OscarTM Power FilterTM QuadraCentric QuadraScopic QuantaMaster RatioMaster TimeMaster TimeMaster Pro O OO OO OVO OVO O 70 50 05 0 20 0 0 No trademark and no material from any PTI documentation may be used in any form without prior written permission from Photon Technology International Inc All pages and their contents are copyright O 2010 Photon Technology International Inc All rights reserved Specificati
9. ons are subject to change without notice All other trademarks are the property of their owners 914 Photomultiplier Detection System 5 PTI Standard Instrument Warranty Warranty Period and Extent Photon Technology International PTI warrants that its instruments will be delivered in a functional state and free from defect and will meet stated specifications for a period of one 1 year The warranty period will start on the date of shipment by PTI In case of systems that include installation by PTI the warranty will start from the date of installation or thirty 30 days after the shipping date whichever is earlier This warranty is in lieu of all other warranties expressed or implied including without limitation the implied warranties of merchantability and fitness for a particular purpose nor will PTI provide training on its use free of charge PTI shall not be responsible for any liability loss or damages caused or alleged to be caused by the system as a result of use or operation including without limitation consequential damages and loss of profit Specific Exclusions and Limitations 1 Itis recognized that the performance of consumable items will diminish as a function of use and that it may be necessary to replace such items to restore the stated specifications Consumable items arc lamps filters cuvettes lenses etc are not covered by the warranty 2 The original manufacturer s warranty will be maintained for major
10. ove with a thin film of saliva Use the 2 5 mm hex key to insert and tighten the four screws to mount the 914 flange to the slit assembly Reconnect the cables removed in step 3 914 Photomultiplier Detection System 13 3 Service Calls to PTI To aid our Service Department in discussing your questions as well as to aid in the timely solution of any problems please assemble as much as possible of the following information before calling PTI e Your system serial number or as many other component serial numbers as possible e The name of the purchaser or principal investigator and the company or institution where the instrument is located e Your instrument type and hardware configuration and software version if applicable e The date on which your instrument was installed e As much detail as possible on the particular chain of events or circumstances that led to the problem This information should include the complete instrument status and data gathering protocol e Ifpossible be prepared to send sample data and hardware and acquisition setup files as email attachments to PTI service personnel Contact PTI Service at Toll Free 877 784 4349 US Canada Phone 609 894 4420 Ext 115 Fax 609 894 1579 Email PTIService pti nj com VISIT OUR WEBSITE AT www pti nj com
11. system components not manufactured by PTI e g computers printers microscopes cameras and components thereof 3 Fiber optic bundles are not covered by the warranty 4 The use of arc lamps not supplied by PTI or approved in writing by PTI will void PTI s warranty on all illuminator subsystem components 5 If there is any evidence of physical contact with coated optics e g fingerprints the warranty on that item will be voided 6 If the optical components are realigned by the customer without specific permission from PTI the warranty will be voided Please note that the customer is responsible for changing lamps and aligning the lamp after installation Aligning the lamp will not void the warranty unless other exclusions are applicable nos 4 and 5 7 Instrument systems that are not authorized to be installed by anyone other than PTI service personnel will not be warranted 8 In case of systems that include installation as part of the original purchase unpacking the instrument by anyone other than PTI personnel will void the warranty 9 Moving systems to another site within a facility or to another location without specific permission from PTI will void the warranty 10 Damage or loss caused by shipping is not covered by the warranty 11 Damage caused by improper operation of the instrument will void the warranty 12 Damage caused by equipment not purchased from PTI that is attached to the instrument is not covered by the warr

Download Pdf Manuals

image

Related Search

Related Contents

国 電池ユニッ ト ソケ" ト  User Manual - Surveillance  MT-1200 User Manual  To insure safe installation and assure the best possible  Whitehaus Collection WHNCMB4413-BSS Installation Guide  Zanussi FJS 1197 W Instruction Manual  Optoma ES522 User Guide Manual  Intellinet 201704 racks  Benutzerhandbuch - Flussgebiete in Hessen  Instructions for Use AD Series Self Retracting Lifelines PART  