1. LX ScrollY Print XY graph nX Zoom Y Z Snapshot XY graph a EE Exit i Fig IV 1 File menu 1 1 File Load BeCOMS BCom logfile Select a BCom file in a standard Windows Open dialog gO d Computer Local Disk C Logfiles gt N O U z ee Zu _ mei Organize v New folder ld Downloads Name i Date modified Type Recent Places Epo ae NO ae 2013071015_Enginel log 10 07 2013 16 00 Tet Document BE Desktop Libraries Documents a Music Pictures BE Videos B nv ME Computer th Network Cantral Danal 4 File name v Logfile log men Fig IV 2 Open dialog _ 1 2 File Print XY graph print the current view of the XY graph using standard Windows Print dialog Data_Indicator_V1 1x_20150216_EN doc Page 12 m et Data_Indicator Professional com User manual 1 3 File Snapshot XY graph create a JPG image out of the current XY graph view Type a file name for the JPG image in the standard Windows Save As dialog then press Save mal Data_Indicator Professional V1 10 C Logdatal 20130415_Engine 4 log File Parameter Polardiagram Setup Simulation OFF Open OMD Mode About m Channels Data_Indicator V Tsignal alarm Date modified MI Desktop IV Speed RPM 10 5 Libraries No items match your search BE Documents a Music Pictures BE Videos Bow J amp E Computer tu Network EE Control Panel MM Twoltage my x50
2. MW Teff DC Zalam File name GbR Save as type Picture jpg X Joo 4 00 4 00 E Search I Telt AC Zalarm Fig IV 3 Save As dialog for menu File Snapshot Data_Indicator_V1 1x_ 20150216 EN doc Page 13 m et Data_Indicator Professional com User manual 2 Setup menu fla Data_Indicator Professional W1 10 File Simulation OFF Open OMD Mode About Chi Setup diagrams croll Scerol Y Scerol Y Cursor Di Setup cylinder range com X zoomt Zooomr Zoom Box Fig IV 4 Setup menu 2 1 Setup Setup diagrams open the Setup diagrams window a Setup diagrams Polar display Scale polardisplay Angle acceleration CO 5 CO 3 Co x 2 E Ei i Sa 003 logfile value Scale polardisplay Thermozsignal da o K3 fm x2 oe x E DO logfile value settings from logfile m Difference diagrams o Difference diagrams in engine geometric order Difference diagram in engine firing order Fig IV 5 Setup scale polardisplay Scaling options for polar diagram Detailed Display window chapter Ill 2 Scale polardisplay Angle acceleration option gives possibilities for scaling the angle acceleration signal Scale polardisplay Thermosignal is a scale factor for thermo voltage signal Difference diagrams chapter III 3 and 4 display option Difference diagrams defines the way the cylinders are ordered at
3. alarm Thermo voltage in percents relative to preset alarm level Speed RPM 10 Engine rotation speed in RPM divided by 10 Tvoltage mV x50 Absolute thermo voltage in mV multiplied by 50 Teff DC alarm Effective value of thermo voltage in percents of DC alarm level Teff AC alarm Effective value of thermo voltage in percents of AC alarm level Initially loaded the data is scaled down so that the chart X axis displays 24 hour interval starting from the first time stamp in the log file The graph has a set of options to navigate through the data and see detailed information at a certain time point Fig III 2 Data_Indicator_V1 1x_20150216_EN doc Page 4 m et Data_Indicator Professional com User manual Double click on the graph to switch on off its options Click an option to change the navigation mode of the graph Scroll X Scroll Y scroll the graph along X or Y axis Scroll XY scroll along both X and Y axis To scroll hold the left mouse button and move the mouse to the desired direction Zoom X Zoom Y enlarge shrink the graph along X or Y axis Zoom XY enlarge shrink along both X and Y axis To zoom hold the left mouse button and move the mouse to the right to enlarge and to the left to shrink the graph in X axis direction Or move the mouse upwards to enlarge and downwards to shrink along Y axis Zoom Box enlarge selected area of the graph Hold the left mouse button and move the mouse to select an area Releasi
4. for sensor Nr 1 The options for gauges include Gauges displayed values f Opacity rel to Slarmlevel m f Temperature mean m e Fig III 8 Gauges options Data_Indicator_V1 1x_20150216_EN doc Page 8 m et Data_Indicator Professional com User manual the Gauges displayed values option allows to select which measurement value to show in the gauge See chapter III 5 2 for description of the values Gauges scale Cf OL 70 0 So 0 150 Fig III 9 Gauges scale the Gauges scale option provides scale ranges for the gauges 5 2 XY graph and options b The XY graph displays measured data from the OMD logfile with time at X axis see chapter Ill 1 1 for description of navigating in the XY graph XY graph options ev graph displayed values Opacity iw Temperature mean W Opacity rel to Alarmlevel i Qilmistmari Reference Transmission Fig III 10 Options XY graph displayed values The XY graph displayed values option allows to select which values from the logfile should be displayed or hidden at XY graph Opacity opacity level in percents 0 transparent environment infra red light beam reaches destination without loss 100 opaque environment infra red light doesn t come through Opacity rel to Alarmlevel Opacity in percents relative to alarm level Reference basis value for calculating Opacity and Opacity rel to Alarmlevel values given in
5. 04 1 07 01 2014 Parameter version W 204 ee m Firing order i p Firing angle 1 Alarmlevel DE Alarmlevweil AC Alarmlevwel AC RPM for Alarmlewel2 AC 1500 Prealarmleyel 70 Alarm Impuls Delay f 20 Alarm Impuls Length Alarm Impuls Level oOo Oo w Mm mm SS Ww RI Engine type 4 stroke fv cylinder Humber of cylinders a i Nominal speed 500 Overspeed 550 Theft for DC measuring El TDC Impulsoffset 222 Evaluator Version va 2181001 Values TnT hertsa CE Start alarminhibit time a0 Evaluator serial number 14 015 DIC Alarm Level percent i al ak fF en TETT I TUT TET Ph Fig IV 10 Parameters screen 6 Polardiagram menu inst Data Indicator Professional V110 CALc y jata 2 20 1302 n 5_Engi Ser A zu u Tao About en Setup Simulation OFF OMD Mode Fie Param eter Channels Angular Signal Data_Indicat Angular Acceleration Fig IV 11 Polardiagram menu Polardiagram menu options allow to display or hide the plot curves of angular signal thermo voltage and angular acceleration rotation speed at the polar diagram Detailed display see chapter Ill 2 If a menu item is checked then the corresponding plot curve is displayed on the polar diagram and hidden otherwise Data_Indicator_V1 1x_ 20150216 EN doc Page
6. 17
7. Data_Indicator Professional User Manual version 1 1x release 16 02 2015 english Kurt Schumacher Str 28 30 66130 Saarbr cken Deutschland e mail info motcomgmbh com web www motcomgmbh com m et Data_Indicator Professional com User manual Contents 1 IMIFOGUGHON sacri cioe pr Heer ee 3 II Installation and setup _ 1 3 III Data reading and analysing _ iii 4 1 Main program window BCom BeCOMs mode 4 FREA ODI iii 4 1 2 Displayed parameters assssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 6 1 3 Time selection asino 6 1 4 Ev nt 109 WINGOW un 6 2 Delalled DISPIOV ici ran 6 3 Speed difference diagram _ uuuuunanunuunnnunununnnnnnununnnnnn nun 7 4 Thermosignal difference diagram _ uuuuusunnunnennnunnunnnnnnanen 7 S OMD MOQO unitari 8 5 1 Gauges and options _ zuununnunnnnunnnnnnnnnunnununnunnnnunnnnnns 8 52 XY graph and options suini 9 5 3 Event log window status messages 10 5 4 Enlarge XY graph button _ uuuuusununnunnnnenunennunnnnnn 10 5 5 OMD mode File menu _ iii 11 VAIO Eee A E A 12 TPH IMO clelinicnicici anioni banali 12 2 SCUD MENU sr iii e 14 3 Simulation OFF ON menu _ rrr rin 15 4 Open OMD Mode menu _ uzuununnunennunennunnnnunnunnnnunnnnnnnnen 16 5 Parameter menu uusssasi sanieren 17 6 Polardiagram menu _ uuuuuunnuunennn
8. dicator Professional com User manual III Data reading and analysing 1 Main program window BCom BeCOMs mode The main program window of Data_Indicator displays an empty graph after start Use File Load menu chapter IV 1 to open a BCom log file Reading a large log file can take some amount of time during which the data is added incrementally to the graph and the amount of read data in per cents is displayed at the bottom left corner of the main panel fm Data_Indicator Professional V1 10 C Logdatal 20130415_Engine 4 log l File Parameter Polardiagram Cancel Setup Simulation OFF Open OMD Mode About Channels Mode Plot Scroll X Scroll Y Scroll XY Cursor Data Indicator Zoom X Zoom Y Zoom XY Zoom Box 150 en nn en nn re Dun Zn Zn En nr en a nt i Tsignal alarm i Speed RPM 10 i iii i Twoltage mv 50 V Tsignal alarm 1 Teff DC alarm 125 ees polli Me ees Teff AC alarm gt Speed RPM 10 100 Iv Tvoltage mv x50 WV Teff DC alarm IV Teff AC Zalarm 0 i 1 i 15 4 00 00 00 15 4 04 48 00 15 4 09 36 00 15 4 14 24 00 15 4 19 12 00 16 4 00 00 00 Select ti 15 04 2013 00 00 00 Log Started i E al 00 2 00 5 00 Fig III 1 Main program window loading a BCom log file 1 1 XY Graph a The graph displays thermo voltage and engine rotation speed data Tsignal
9. digits Temperature mean sensor average temperature in C Oilmist mg l absolute concentration of oil mist in mg l Transmission amount of light that reaches destination in the measuring unit of OMD sensor Given in digits a raw measurement value Sensor initially calibrated in a transparent environment shows transmission about 1000 digits Data_Indicator_V1 1x_20150216_EN doc Page 9 m et Data_Indicator Professional com User manual ars scale Po O10 f O 50 f D0 150 Fig III 11 Y Axis scale options Y Axis scale option sets the range to be used at the Y axis The same could be achieved through options menu inside the XY graph with Zoom Y command 5 3 Event log window status messages c 09 20 2013 16 24 30 Measure Stopped sd 09 20 2013 16 24 30 Measure Stopped Fig III 12 Event log window Displays event messages and warnings produced by the OCom SICOMS system during monitoring Double click anywhere at its field to open a larger status window with event log E 09 20 2013 00 00 00 Log Started 09 20 2013 16 24 30 Measure Sto 09 20 2013 16 24 30 Measure Stoppe Fig Ill 13 Status window 5 4 Enlarge XY graph button d pressing the button extends the XY graph window The button caption changes to Reduce XY graph Data_Indicator_ V1 1x_ 20150216 EN doc Page 10 m et Data_Indicator Professional com User manual 5 5 OMD mode File
10. menu Parameter Load SICOMS Ocom logfile Exit Stop logfile loading 150 150 Swap Month Day 156 Print xy diagram a Ee 100 100 5 5 1 Load SiCOMS Ocom logfile opens a logfile recorded by SICOMS or Ocom system 5 5 2 Stop logfile loading cancels loading of the current logfile 5 5 3 Swap Month Day changes appearance of day and month in the date label at XY graph Useful for some region language Windows settings that have different date format than English US Windows settings 5 5 4 Print xy diagram this menu prints the current view of XY graph using standard MS Windows Print dialogue 5 5 5 Exit closes the OMD mode window 5 5 6 Parameter opens a window with Evaluator version info Am SICOMS OCom Parameter m Parameter Evaluator ID Code 02M 01 Evaluator Version Puy 2 0081004 Evaluator serial number lest 0 Ha connected sensors F Refresh Fig III 15 OMD File menu Data_Indicator_V1 1x_20150216_EN doc Page 11 m et Data_Indicator Professional com User manual IV Menus On program start before a logfile loaded the main menu has five items File Setup Simulation OFF Open OMD Mode About After loading a BCom data file the main menu is extended File Parameter Polardiagram Setup Simulation OFF Open OMD Mode About 1 File menu UE Data Indicator Professione VIIO N Setup Simulation OFF Open OMD Mode About Load BeCOMS BCom logfile F2
11. n OMD Mode menu The Open OMD Mode menu command opens a window for viewing SICOMS OCom logfiles Gauges displayed values Opacity Opacity rel to Alarmlevel Reference Temperature mean Dilmist mg l Transmission 0 0 o 0 0 E o 0 0 0 0 0 o 0 0 0 0 ii fo fo foo ES DI Coo oo DD I es fo aII v1 M 2 M 3 M 4 M 5 M 6 MT M 8 M 9 ve M 11 MMR MB M 14 M 15 M 16 Show none in chart Axis scale Relay Status 2Min 1 Hour a Ready Relay Alarm Relay 2 Alarm Relay 1 6Hours et l 7 Data Indicator for SiCOMS OCom logfiles Enlarge XY graph PPP O T T rr rT T _o_ _ _____ RUMUMuo rr WWW _1 1_0 gt gt gt 6sibgb H pt q lt amp W W0Wq lt lt _K amp lt __ Fig IV 8 SICOMS OCom window See OMD mode chapter III 5 for detailed description Data_Indicator_V1 1x_20150216_EN doc Page 16 m et Data_Indicator Professional com User manual 5 Parameter menu ia Data Indicator Professional W110 CALogdatal 20130415 _ Engine 4 log Parameter Polardiagram SS simulation OFF Open OMD Mode About Show Parameters Scroll X Scroll Scroll XY Cursor Zoom K Zoom Y Zoom XY Zoom Box Data_Indicator Fig IV 9 Parameter menu This menu opens the Parameters screen which displays BCom Evaluator and engine parameter values that were set up at the time of log file recording Logfile version BCom Version 2
12. ng the mouse button stretches the selection to the frame of the graph Cursor display the X and Y values of the selected plot point and open three additional windows Detailed Display Thermosignal difference diagram and Speed difference diagram chapter I 2 3 and 4 Fez z n ee ee fm Data_Indicator Professional V1 10 C Logdata1 20130415_Engine 4 log m File Parameter Polardiagram Setup Simulation OFF Open OMD Mode About Channel dei Mode Plot ScrollX Scroll Y Scroll XY Cursor X 15 4 03 32 53 Y 4 Data Indicator Zoom X Zoom Y Zoom XY Zoom Box ee a a a nnn nnn nee nn yen ne ene penne eee eee es anal clara Speed RPM 10 ae i i i Tvoltage mV x50 V Tsignal alarm Teff DE alarm Oh passes IEEE TITTI porcata dare EEE EEE PET Teff AC Zalarm R Speed RPM 10 VSS I I I II RI RIA IV Tvoltage m x50 iV Teff DC alarm rt Fi bi ith ImM ui Ji Lula il VW Teff AC Zalarm i i I i i i i 15 4 00 03 49 15 4 01 31 10 15 4 02 52 31 15 4 04 13 52 1544 05 35 13 15 4 06 56 34 __ _________ 14ktk_ _ ____ _ gt vr_ _T r_ _ _ _ _ Selectti 15 04 2013 00 00 00 Log Started s 4 ui i al gt 03 A 32 53 Search 100 Fig III 2 Main program window time scale X axis enlarged chart in Cursor mode Plot return the graph t
13. o its default scale Data_Indicator_V1 1x_20150216_EN doc Page 5 m et Data_Indicator Professional com User manual 1 2 Displayed parameters b Tsignal alarm display hide thermo voltage signal in per cents at the graph Sped RPM 10 display hide rotation speed signal Tvoltage mV x50 display hide absolute thermo voltage values in mV Teff DC alarm display hide effective thermo voltage in of DC alarm level Teff AC alarm display hide effective thermo voltage in of AC alarm level 1 3 Time selection c Allows to select a time point from the log file Measurement data recorded at this point will be displayed in detailed display window speed difference diagram and thermosignal difference diagram windows 1 4 Event log window d Displays event messages and warnings recorded in the BCom data log file Double click anywhere at its field to open a larger window with event log Status window 2 Detailed Display iR Am Detailed Display Es _ Angular Signal 13 32 27 Thermosignal abs 13 32 27 average value m et Al Angular Acceleration 13 32 26 He BS BE B3 B9 B5 B1 B7 B4 B2 Al A AA A2 AB AE A3 AI AS Fig III 3 Detailed Display Open on Cursor command of XY graph Detailed Display window contains a polar diagram which plots thermo voltage and crankshaft angle acceleration in polar coordinates during the full combustion cycle nearest to the time poin
14. onal com User manual 5 OMD Mode OMD mode window allows viewing and analysing SICOMS OCom logfiles I SICOMS OCom Mode Loaded File C Logdatal omd 20130920 Main Enginel log File Parameter Sensor Gauges Gauges displayed values N Opacity rel to Alarmlevel Reference C Temperature mean Dilmist mg l Transmission Gauges scale 9 RI I I C II Eo V1 WNW2 K3 WA MS MI K8 M9 WO EN FRAR MB M 15 M 16 Show none in chart XY graph GRES rino is EEE A sos ERE ER EER EERE i i i i i Ilio a n _ eee ee 100 sli LL rp __________________ pi _ ____ __ _ __ 0 Ul er x I L Ul 3 9 20 10 24 28 9720 11 54 28 9 20 13 24 28 9 20 14 54 28 9 20 16 24 2 XY graph displayed values Y Axis scale E V Temperature mean C 0 IV Opacity rel to Alarmlevel IV Dilmist mgA en IV Reference VW Transmission Du et mat Data Indicator for SiCOMS OCom logfiles E Fig III 6 SICOMS OCom window with a loaded logfile 5 1 Gauges and options a a Each gauge displays the measurement value selected in gauges 125 options for the corresponding sensor 100 x digital display of the value 50 sensor number and a switch checkbox If It is checked the 25 measurement values for the corresponding sensor are shown in XY graph otherwise the values are hidden Emm v4 Fig III 7 Gauge
15. t selected at the XY graph chapter Ill 1 1 At the right side of it there s an XY diagram of the polar data with X axis representing the rotation angle Data_Indicator_V1 1x_20150216_EN doc Page 6 m et Data_Indicator Professional com User manual 3 Speed difference diagram im Speed difference diagram NI r speed difference diagra Speed absolut Speed relative Cylinder A3 B3 A4 B4 AS BS AS B8 AT B7 4 stroke engine 18 cylinder V type Time 13 36 58 Fig III 4 Speed difference diagram The diagram shows absolute cylinder speed blue bars and the difference between engine cylinder speed pink bars relative to the cylinder average speed during the nearest full combustion cycle 4 Thermosignal difference diagram im Thermosignal difference diagra linder thermosignal difference diagra Signal absolut Signal difference Thermosignal in Alarmlevel S E gt c R a 5 Cylinder A2 B2 A3 83 Ad B4 AS BS A6 B6 AT BT AB BE 4 stroke engine 18 cylinder W type Time 13 37 00 Fig III 5 Thermosignal difference diagram The red bars at the thermosignal difference diagram represent thermo signal in per cents of alarm level during the nearest full combustion cycle The pink bars show this value relatively to the engine cylinder average thermosignal Data_Indicator_V1 1x_ 20150216 EN doc Page 7 m et Data_Indicator Professi
16. the difference diagrams Data_Indicator_V1 1x_20150216_EN doc Page 14 m et Data_Indicator Professional com User manual 2 2 Setup Setup cylinder range met r Setup Setup encoder steps for cylinder 1 detection in difference diagrams ui default Fig IV 6 Setup cylinder range The number inside the selection box defines how many steps of the total 256 steps in the full cycle should correspond to the top position of a cylinder during the combustion cycle The value ranges between 1 and 10 it is used to adjust the sensitivity of signal localisation algorithm 3 Simulation OFF ON menu The menu gives a possibility to scale the logdata values and so simulate different BCom Evaluator settings of DC alarm level DC alarm level 1 simulation DC alarm level 1 simulation simulate increase decrease of DC alarm level by 1 step and display scaled logdata To actualise data view after changing alarm level load the log file again DC alarm level simulation OFF display logdata without scaling fy Data Indicator Professional V1 10 File Setup Simulation OFF Open OMO Mode About Channels DC alarm level 1 simulation Scerol XY Cursor Data Inc DC alarm level 1 simulation Zoom XY Zoom Box Y DE alarmlevel simulation OFF Fig IV 7 Simulation OFF ON menu Data_Indicator_V1 1x_ 20150216 EN doc Page 15 m et Data_Indicator Professional com User manual 4 Ope
17. unnunnnnnnnnnnnunnunnnnnnnnnun nun 17 Data_Indicator_V1 1x_20150216_EN doc Page 2 m et Data_Indicator Professional com User manual I Introduction Data_Indicator Professional is a PC application used in the BCom and OCom systems for displaying and analysing previously recorded BCom and OCom log files The Evaluator provides instant information on several important engine condition parameters BCom Data Logger and OCom Logger programs constantly monitor and display this information and record it into log files If parameter values indicate a dangerous situation for the engine it can be stopped through an alarm system or manually to avoid serious damages At the same time review and analysis of recorded log data give more detailed view on engine health ll Installation and setup In order to install Data_Indicator on a computer with Windows operating system double click at setup exe on a provided installation CD or other media Follow the instructions in the setup program After the installation is finished Data_Indicator can be started through a program group in Windows Start menu de Data Indicator V1 10 Ga Data_Indicator_V1 10 system requirements Intel Core2Duo processor 2 66 GHz or higher e CD Rom drive recommended CD R W drive min 2GB DDR2 RAM hard disk with a capacity of min 160 GB supports Windows XP Windows Vista Windows 7 Windows 8 x Data_Indicator_V1 1x_20150216_EN doc Page 3 m et Data_In