Home

User manual ArcWash Recessed 236

image

Contents

1. indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective Or its driving IC on the main PCB The head is not located in the default position after the reset 16 10 Technical specifications Power supply Input Voltage 100 240V AC 50 60 Hz Fuse T 2 A Max Pover Consumption 135 VA Optical system 36 RGB Luxeon K2 LEDs Standard 6 beam angle lenses Optional 25 beam angle lenses Beampath Beam angle 6 1 50 0 5 1 1 5 2 3 4 5 Distance m T T pa E to Pos 5 1 N o a 0 T E E 0 5 3 D 10 i 1 1 1 59 0 05 01 016 02 0 31 0 42 0 52 Diameter m Distance m 0 5 1 0 1 5 2 0 3 0 4 0 5 0 Red 24000 2229 6000 557 2667 248 1500 139 667 62 375 35 240 22 Green 30000 2787 7500 697 3333 310 1875 174 835 78 469 44 300 28 ntensity center Blue 2800 260 700 65 311 29 175 16 78 7 44 4 28 3 Lox Footcandies White 55200 5128 13800 1282 6133 570 3450 321 1533 142 862 80 552 51 Diameter m 0 05 0 1 0 16 02 0 31 0 42 0 52 Distance 4m 1000 93 LUX Foot candles 800 A 74 600 56 400 dot lt 37 200 27 Tee 19 oERELLLI MEREBT dd4 HLLLIZET3 1 08 06 04 02 0 02 04 06 08 1 Diameter m white red eee green blue Strobe Strobe effect with variable speed max 25 ashes per
2. second Preprogrammed random strobe pulse effects Dimmer Smooth dimmer from 0 100 Motors 2 high quality stepping motors controlled by microprocessors Electronics Addressing special functions setting manual control via control panel with 4 digit LED display Built in analyzer for easy fault finding error messages Bilt in demo sequences Black out while head moving Silent fans cooling Digital serial input DMX 512 Master slave operation DMX control via every standard DMX controller control channels 8 or 14 Pan Tilt Pan movement range 530 Tilt movement range 280 8 16 bit movement resolution Automatic pan tilt position correction Remotely controllable speed of pan tilt movement for easy programming Rigging Ceiling box for 600x600 or 625x625 mm grid mounting or version for plaster boards Integral attachment points for wire hangers or all thread support 17 Data input output 3 pin XLR male socket for DMX data input 3 pin XLR female socket for DMX data output Temperatures Maximum ambient temperature 40 C Maximum housing temperature 65 C Minimum distances Min distance from ammable surfaces 0 5 m Min distance to lighted object 0 7 m Dimensions mm version for 600x600mm mounting grid 565 C i N o o o o o o o a Q Q Q o gt amp S gt 38 Y e e i Sat BB H
3. select the desired program which you wish to edit and press ENTER 3 Press UP or DOWN to select the desired program step St 01 St 30 and press ENTER 4 Press UP or DOWN to select the desired item and press ENTER button Now you can edit by using UP or DOWN buttons the DMX values of selected item P End a total number of the program steps value 1 30 This value must be set before start programming e g if you want to create program with 10 steps set P End 10 PAn a coarse pan movement GrEE a green LED saturation F PAn a fine pan movement bLuE ablue LED saturation tilt a coarse tilt movement MACr acolour macros F tilt a fine tilt movement Stro a strobe shutter SpEd a pan tilt speed dimr a dimmer P t SE a pan tilt macro selection P t SP a pan tilt speed rED a red LED saturation F tim fade time value 0 255 S tim standing time value 0 255 COPY copying the current prog step to the next prog step Press ENTER button to confirm adjusted value 5 Repeat steps 3 and 4 for next prog step If you want to copy current prog step to the next prog step select option COPY and confirm it by pressing ENTER 14 Both Fade time and Standing time use the same conversion table in order to convert DMX value to the time value Exact expression of the time value follows the formula time sec DMX value 10 MASt Master Enter this menu if you want to set the the fixture as a master Use U
4. 0 200 255 GrE b 0 255 pLu b 0 215 255 I bli On Off dFSE Pan 0 255 dimr 0 255 EPG 1 EPG 2 PrG 6 Auto On Off Audi On Off Edit EPG 1 EPG 2 St 01 EPG 3 St 30 P End PAn 0 255 dimr 0 255 F tim 0 255 S tim 0 255 COPY MaSt EPG1 PrG 6 SLA uPd M No Yes 7 Functions of the control panel The control panel situated on the front panel of the base offers several features You can simply set the DMX address run programs make a reset and also use many functions for setting the fixture behaviour Control elements on the control board MODE button leaves menu without saving changes ENTER button enters menu confirms adjusted values and leaves menu UP button and DOWN button moves between menu items on the the same level sets values After switching the fixture on the display shows the initial screen Use UP DOWN to browse through the menu To select a function or submenu press ENTER 7A Fixture Address Use this menu to set the DMX start address of the fixture which is defined as the first channel from which the ArcWash Recessed 236 will respond to the controller If you set for example the address 15 the ArcWash Recessed 236 will use the channel 15 to 28 for control if Mode 1 is selected Please be sure that you don t have any overlapping channels in order to control each ArcWash Recessed 236 correctly and independently from any ot
5. 12 DM Pr DMX preset Select this item to choose desired DMX mode Please refer to the chapter DMX protocol for detail description Mi SE Microphone sensitivity Select this function to adjust the microphone sensitivity from 1 maximum to 20 minimum If the sensitivity is correctly adjusted the upper segment of the first digit blinks in the bass beat Examples 1 J 4 J 4 J CL NG l L underexited right level overexited upper segment blinks FEEd Pan Tilt feedback This function allows to return the mowing head to the required pan tilt position after changing the position by external force e g by stroke Be careful the Pan Tilt Feedback OFF is not the standard operation and the head of the fixture can be de maged Note If the feedback was switched off the pan tilt position is changed by an external force and the feedback is switched on again the moving head might not to be synchronized with the DMX signal You have to make a reset in order to syn chronize the moving head with the DMX signal P t Mo Pan tilt movement mode Use this menu to set the character of the pan tilt movement ti Mo Time mode Pan and tilt will move with different speeds and they will come at the same time to end point pan and tilt sets its optimal speed SP Mo Speed mode Pan and tilt will move with the same speed as adjusted at the channel 5 Pan Tilt speed E g pan will come to the end point and wait for tilt which has longer tr
6. ANOLIS Le m N U Uu 7 a Q o c 7 O i lt USER MANUAL ArcWash Recessed Table of contents 1 Safety INSIUCHIONS cc RER EEE nam anna nn paa aaa Hau Han aan Ra Eupen Euren anne udn 4 2 Operating determinallOns neun NGABA as 4 3 Description Of tie device ana crap n red AA 5 Mnt 6 4 1 Mounting the Tatu ii tb nenne 6 4 2 Fitting the frost filtr euunnunnnnennunnnnnnnnnnnnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnrnnnnnn nennen nnennnn nn 7 4 3 DMX 512 connection connection between fixtures sise 8 5 ArcWash Recessed 236 DMX protocol version 1 0 cese 9 6 ArcWash Recessed 236 Control menu Map ss 11 7 Functions of the control PM dunnuna naana unuraa ananena seseina 12 7 1 Fixture A CGI CSS sissies 12 7 2 Due reet 12 EXP POTS ONLY eR 1 02 12 YE MANUAL MOOG EN 13 7 5 NI E 14 7 6 R set TUNCHON E A 15 7 7 Special FUNCTIONS MASA 15 8 Power down MOE cum a 16 9 Error and information MOSSOS caciones na 16 10 Technical Secc MON Sisi 17 11 Maintenance and cleaning cn 19 12 Ceiling boxes versions and dimensions ns 20 CAUTION Keep this device away from rain and moisture Unplug mains lead before opening the housing FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CARE
7. FULLY BEFORE YOU INITIAL START UP 1 Safety instructions Every person involved with installation and maintenance of this device have to be qualified follow the instructions of this manual CAUTION Be careful with your operations With a high voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe ope ration it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Important The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty Make sure that the available voltage is not higher than stated on the rear panel f the device has been exposed to drastic temperature uctuation e g after transportation do not switch it on immedia tely The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Always disconnect from the mains when the device is not in use or before cleaning it This device falls under protection class Therefore it is essential to connect the yellow green conductor to earth The electric connection repairs and servicing must be carried ou
8. P 83 333 SEES m 595 2 u 574 Pd ER ty Weight moving head 8 8 kg Weight ceiling box 7 0 kg Accessories Erostitilmfilt r SOM oi en nina No 14060091 No 14060092 Frost film filter dense iiie amma 18 Optional accessories Flash cable RS232 DMX ccccscceeeeseceeseeeeeeeeeeeseaeeeeseeeeseneeeeees No 13050624 11 Maintenance and cleaning It is absolutely essential that the fixture is kept clean and that dust dirt and smoke uid residues must not build up on or within the fixture Otherwise the fixture s light output will be significantly reduced Regular cleaning will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life A soft lint free cloth moistened with any good glass cleaning uid is recommended under no circumstances should alcohol or solvents be used DANGER Disconnect from the mains before starting any maintenance work The front objective glass will require weekly cleaning as smoke uid tends to building up residues reducing the light output very quickly The cooling fans should be cleaned monthly The interior of the fixture should be cleaned at least annually using a vacuum cleaner or an air jet More complicated maintenance and service operations are only to be carried out by authorized dealers Replacing
9. P and DOWN buttons to select desired program and press ENTER to confirm selection SLA Slave Select this menu if you want to set the the fixture as a slave 7 6 Reset function This option enables the ArcWash Recessed 236 to index all effects and return them to their standard positions 7 7 Special functions Use this menu for special services like software update uPd M Updating mode Using this function you can update software in the fixture via PC and serial link The following are required in order to update software PC running Windows 95 98 2000 XP or Linux DMX Software Uploader Flash cable RS232 DMX No 13050624 Note1 Software update should execute a qualified person If you lack qualification do not attempt the update yourself and ask for help your ROBE distributor Note 2 DMX address IP address programs 1 3 and all functions in menu PErS will be set to their default values To update software in the fixture 1 Installation of DMX Software Uploader 1 DMX Software Uploader program is available from the ROBE web site at WWW robe cz 2 Make a new directory e g Robe_Uploader on your hard disk and download the software to it 3 Unpack the program from the archive If the Robe fixture is produced in magnetic and electronic ballast version name of DMX Software Uploader is the same for both versions 2 Fixture software updating 1 Determine which of your COM port is available on your PC and connect it w
10. ack bL Co Blackout during movement correction Select this function to enable the blackout during the head movement correction if the moving head lost its right pan tilt position for a short moment bl P t Active Blackout while Pan Tilt moving Use this function if you wish to close the light output during pan tilt changes bALA Balance Select this function to enable On or disable OFF the white balance which is set in White colour balance menu below If this function is set OFF ArcWash Recessed 236 will use maximum values 255 of saturation for red green and blue channel C bAL White colour balance Using this menu you can set the white balance 1 Browse through the menu by pressing the UP and DOWN buttons until the display shows C bAL menu Press ENTER button and rEd b will appear on the display 2 Press ENTER button again and use UP and DOWN buttons to adjust the new maximum value required for the red channel Confirm your choice by pressing ENTER Use the UP and Down buttons to select next colour 3 Repeat step 2 for green channel GrE b and for blue channel bLu b i bLi Initial blink If this function is on ArcWash 236 LT makes auto calibration All LEDs light on 100 for a short time after switching the fixture on If this function is set off you have to set manually every colour on max brightness after Switching on the driver before starting regular operating This action should las
11. at 0 DMX 7 0 No macro generation step 1 127 Macro generation from fast to slow forwards proportional 128 129 No macro generation step 130 255 Macro generation from slow to fast backwards proportional Special functions 0 129 Reserved 130 139 Panttilt reset step 140 255 Reserved proportional proportional proportional Mode 1 Mode 2 136 143 Macro 17 142 151 Macro 18 152 159 Macro 19 160 167 Macro 20 168 175 Macro 21 176 183 Macro 22 184 191 Macro 23 192 199 Macro 24 200 207 Macro 25 208 215 Macro 26 216 223 Macro 27 224 231 Macro 28 232 239 Macro 29 240 247 Macro 30 248 255 Macro 31 Rainbow effect SHUTTER STROBE 0 31 Shutter closed step 32 63 Shutter open step 64 95 Strobe effect from slow to fast proportional 7 96 127 Shutter open step 128 143 Opening pulses in sequences slow gt fast proportional 144 159 Closing pulses in sequences fast gt slow proportional 160 191 Shutter open step 192 223 Random strobe effects from slow to fast proportional 224 255 Shutter open step DIMMER 0 255 Dimmer intensity from 0 to 100 proportional 10 6 ArcWash Recessed 236 Control menu map Default settings Bold print A001 001 498 tEMP VErs EE Cto IC2 b r PAn On Off r tilt On Off MI SE 1 10 20 dM Pr Mod 1 Mod 2 FEEd On Off P t Mo SP Mo ti Mo bL Co On Off bl P t On Off BALA On Off C bAL rEd b
12. chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 Ohm resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Building a master slave chain Connect the DMX output of the master fixture in the data chain with the DMX input of the first slave Always connect output with the input of the next slave until all slaves are connected up to 32 fixtures Caution It s necessary to insert the XLR termination plug with 120 Ohm into the input of the master fixture and into the output of the last slave fixture in the link in order to ensure the proper transmission on the data link mg ne Ye TT ae pak um iJ DMX operation DMX512 i i Master slave operation 1200 5 ArcWash Recessed 236 DMX protocol version 1 0 Mode 1 Mode 2 Type Pan a La 0 255 pan m
13. d the moving head installati on The ceiling box must be fixed properly otherwise the vibration of the mounting structure can occur during the operation of the moving head Pull the power cable 5 and data cables through the apertures 1 on the bottom of the box 2 Put the moving head base 4 on the 4 fixative pins 6 in the bottom of the ceiling box 8 and turn the base gently to the right Insert and tighten clockwise the 2 quick lock fasteners 7 to secure the moving head in the ceiling box 3 Use the 3 wired power cable the wires with cross sectional area of 1 5mm to connect the power Pull the power cable through a cable holder 3 and connect it into the connection terminals 2 as follows Possible pin identification schemes Cable EU Cable US Pin International Green Connect the earth wire 10 with the earth terminal 9 on the ceiling box 8 If you have any doubts about proper installation consult a qualified electrician Make sure the wires are securely connected Tighten 2 screws in the cable holder to secure the power cable in it For protection from electric shock the fixture must be grounded 4 Connect the data cables to the fixture DMX input output 5 Fasten 2 covers on the ceiling box by 14 screws DANGER TO LIFE For protection from dangerous electr
14. have to repeat the software update again For example The fixture was switched off before finishing software upload After switching the fixture on again the fixture is still in the update mode and the display is dark Restart the Software Uploader program and repeat software update from your PC 8 Power down mode This mode omits fixture reset after switching the fixture on and lowers motor powers of the fixture Power down mode is useful in special casech g if the fixture is in a ight case and you want to set its DMX address without taking it out from the case To enter Power down mode press and hold UP and DOWN and at the same time switch on the Power switch The following message appears on the display P d Mo Press ENTER to activate Low power mode without fixture reset Now you can set features and behaviour of the fixture by using Pers menu If you want to go normal operation mode execute fixture reset Note All motors in Power down mode are deactivated 9 Error and information messages PA Er Pan yoke movement error This message will appear after the reset of the fixture if the yoke s magnetic indexing circuits malfunction sensors failed or magnet missing or the stepping motor is defective Or its driving IC on the main PCB The yoke is not located in the default position after the reset ti Er TILT head movement error This message will appear after the reset of the fixture if the head s magnetic
15. her fixture on the DMX data link If two three or more ArcWash Recessed 236 are addressed similarly they will work similarly After having addressed all ArcWash Recessed 236 you may now start operating these via your lighting controller Note After switching on the ArcWash Recessed 236 will automatically detect whether DMX 512 data is received or not If there is no data received at the DMX input the display will start to ash A001 with actually set address This situation can occur if the 3 PIN XLR plug cable with DMX signal from controller is not connected with the input of the ArcWash Recessed 236 the controller is switched off or defective the cable or connector is defective or the signal wires are swaped in the input connec tor 7 2 Fixture informations Use this menu to read an useful information about the fixture tEMP Fixture temperature The function shows the temperature in the fixture head C Please note that the outside temperature should not exceed 40 C VErS Software version Select this function to read the software version of processors IC1 b Main processor on the main board in the fixture base IC2 b Pan tilt processor on the main board in the fixture base 7 3 Personality Use this menu to to modify the ArcWash Recessed 236 operating behavior r PAn Pan reverse Select this function to invert the pan movement r tilt Tilt reverse Select this function to invert the tilt movement
16. ic shock the fixture must be installed in ceiling box and covered with box covers before applying power Before taking into operation for the first time the installation has to be approved by an expert When installing fixtures side by side avoid illuminating one fixture with another 4 2 Fitting the frost filtr The ArcWash Recessed 236 is supplied with clear front glass factory fitted and two types of frost filters films If you wish to use a diffusive light follow the steps to install desired frost filter 1 Remove the ring 1 from the forefront 2 Put the frost film on the front glass and centre the holes of the head by loosening both fastening in the film on the holes in the holder of the glass screws 2 3 Put the ring carefully back and tighten both fastening screws 4 3 DMX 512 connection connection between fixtures The fixture is equipped with 3 pin XLR sockets for DMX input and output Only use a shielded twisted pair cable designed for RS 485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection DMX output DMX input XLR mounting sockets rear view XLR mounting plugs rear view nagi 1 Shield 2 Signal 3 Signal Building a serial DMX chain If you are using the standard DMX controllers you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX
17. ith to the DMX input of the fixture using the uploading cable Do not extend this cable Disconnect the fixture from the other fixtures in DMX chain Turn on the computer and the fixture Make sure the lamp is switched off 2 Switch the fixture to the update mode by selecting the option Updating mode in menu Special Functions on the fixture control panel SPEC gt UPd gt yES From this option you cannot return back to the main menu If you do not want to continue in software update you have to switch off and on the fixture to leave this option 15 3 It is recommended that you exit all programs before running the Software Uploader 4 Start the Software Uploader program Select desired COM and then click Connect button If the conection is OK click Start Uploading button to start uploading It will take several minutes to perform software update If the option Incremental Update isn t checked all processors will be updated including processors with the same software version If you wish to update only later versions of processors enable the Incremental Update check box Avoid interrupting the process Update status is being displayed in the list window When the update is finished the line with the text The fixture is successfuly updated will appear in this window and the fixture will reset with the new software Note In the case of interruption of the upload process e g power cut the fixture remains in the update mode and you
18. lisions can occur and the fixtures will not work properly It s necessary to insert the XLR termination plug with 120 Ohm into the input of the master fixture and into the output of the last slave fixture in the data link in order to ensure proper transmission on the data link Operating multiple fixtures in stand alone mode 1 Select one fixture and set it as a master and select a program which is to be played Menu path St AL gt MASt 2 The rest of the fixtures set as slaves Menu path St AL gt SLA 3 Build the master slave chain See chapter DMX 512 connection and Master Slave connection Audi Music trigger Select this function to enable the sound control of the running programs via the built in micro phone EPG1 PrG 6 Fixture programs By pressing ENTER selected program will run in a loop Auto Automatically playback If this function is on the fixture in DMX mode remembers last running program and this program will run after switching the fixture on Edit Editing program The fixture includes 6 built in programs PrG 1 PrG 6 and 3 free editable programs EPG 1 EPG 3 each up to 30 steps Every program step has a fade time the time during which effects except pan tilt go to the current step and a standing time the time during which effects last in the current step current step li Fade time Standing time Programming procedure 1 Enter Edit menu 2 Press UP or DOWN to
19. ovement by 530 proportional Pan Fine ER Baesa Fine control of pan movement proportional Tilt 0 255 Tilt movement by 280 pr porti nal Tilt fine PESE Fine control of tilt movement proportional Pan Tilt speed Pan Tilt time Max speed tracking mode step P T speed set Speed Mode in menu P T Mode Speed from max to min vector mode proportional P T time set Time Mode in menu Pan Tilt Mode Time from 0 1 s to 25 5 s proportional Pan Tilt macro selection 0 9 Disabled pan tilt macro step 10 31 Reserved step 32 63 Figure of circle from small to large proportional 64 95 Figure of horizontal eight from small to large proportional 96 127 Figure of vertical eight from small to large proportional 128 159 Figure of rectangle from small to large proportional 160 191 Figure of triangle from small to large proportional 192 223 Figure of five pointed star from small to large proportional 224 255 Figure of cross from small to large proportional 0 255 0 255 0 255 104 111 112 119 120 127 128 135 Red LED Red LED saturation control 0 100 Green LED Green LED saturation control 0 100 Blue LED Blue LED saturation control 0 100 Colour MACRO SELECTION No function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 Macro 16 Pan Tilt macro speed Set pan tilt speed channel 5
20. sult of unprofessional operation Please use the original packaging if the device is to be transported Please consider that unauthorized modifications on the device are forbidden due to safety reasons DANGER TO LIFE For protection from dangerous electric shock the fixture must be installed in ceiling box and covered with box covers before applying power 3 Description of the device 1 Ceiling box 2 3 Box covers 4 Arm 5 Front glass 6 Moving head Moving head s base 7 Control panel 8 DMX output 9 DMX input 10 Fuse holder 11 Power terminals 12 Moving head base 1 Ceiling box Control panel 13 Display 14 Mode button 15 Enter button Y 16 Up button 17 Down button o LUN Cnm O O P am gt NI Q o 3 2 g a c o D 8 a O 0 E Bm mh al ES o N 8 4 Installation 4 1 Mounting the fixture The moving head is designed for ceiling mounting The installation is of the projector has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation When rigging derigging or servicing the fixture staying in the area below the installation place under high working places and other endangered areas is forbidden The operator has to make sure that safety relating and machine technical installations are appro
21. t by a qualified employee Do not connect this device to a dimmer pack During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective Do not touch the device s housing bare hands during its operation housing becomes hot CAUTION EYEDAMAGES Avoid looking directly into the light source meant especially for epileptics 2 Operating determinations This device is a moving head spot for creating decorative effects and was designed for indoor use only Do not shake the device Avoid brute force when installing or operating the device Never lift the fixture by holding it at the projector head as the mechanics may be damaged Always hold the fixture at the transport handles When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust The minimum distance between light output and the illuminated surface must be more than 0 8 meter Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture 4 Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened The maximum ambient temperature 40 C must never be exceeded Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the re
22. t min one second for every colour dF SE Default Settings Select this option to reset all fixture personalities to the factory values 7 4 Manual mode Select this menu to control channel effects by control buttoms on the control board without an external controller PAn a coarse pan movement GrEE a green LED saturation F PAn a fine pan movement bLuE ablue LED saturation tilt a coarse tilt movement MACr acolour macros F tilt a fine tilt movement Stro astrobe shutter SpEd a pan tilt speed dimr a dimmer P t SE a pan tilt macro selection P t SP a pan tilt speed Func a special function rED a red LED saturation 13 7 5 Test sequences Use this menu to to run a demo test sequences without an external controller which will show you some possibilities of using ArcWash Recessed 236 7 6 Stand alone setting The fixtures on a data link are not connected to the controller but can execute pre set programs which can be different for every fixture Stand alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master MSt and the rest as the slaves SLA Up to 32 fixtures can be connected in master slave chain Only one fixture can be set as the master Note Disconect the fixtures from the DMX controller before master slave operating otherwise data col
23. the fuse If the lamp burns out the fine wire fuse of the device might fuse too Only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure 1 Unscrew the fuseholder on the rear panel of the base with a fitting screwdriver from the housing anti clockwise 2 Remove the old fuse from the fuseholder 3 Install the new fuse in the fuseholder 4 Replace the fuseholder in the housing and fix it 19 12 Ceiling boxes versions and dimensions Version for 600x600mm mounting grid Ceiling box Box covers 99010551 19010084 19010083 Box covers 20 Version for 625x625mm mounting grid Ceiling box Box covers 99010691 19010112 19010111 Box covers 21 Version for lower ceiling from plaster boards Ceiling box Box covers 99010551 19010114 19010113 Installation Box covers 22 Ceiling box No 99010551 Mounting holes dlameter 12 mm All dimensions are in mm Specifications are subject to change without notice 23 Ceiling box No 99010691 l l O e 100 100 8x935 6x 12 Cable holes diameter 35 mm 19 R 3 Q 43 40 ID b o o o e FR 3 Mounting holes dlameter 12 mm 565 617 All dimensions are In mm 24 25
24. ved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year The moving head should be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including calculating working load limits installation material being used and periodic safety inspection of all installation material and the projector If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury and or damage to property The moving head should be installed out of the reach of people Danger of fire When installing the device make sure there is no highly in ammable material decoration articles etc in between a distance of min 0 5 m CAUTION Make sure that the device is fixed properly Ensure that the structure truss to which you are attaching the fixtures is secure The ArcWash Recessed 236 includes a moving head and a ceiling box for mounting to the lower ceiling Installation 1 Fix the recessed ceiling box 8 to the lower ceiling Be careful the mounting grid can hol