Contents
1. flash PAGE7 JADEVER http www jadever com tw JWP 7 Set the figure with the procedure in 5 and then press down key TARE to confirm it and begin setting the figure at the next digit 8 After completing the setting of the last digit the number of the articles will be displayed on the screen at the same time lamp Counting will light up 9 Power on the balance again The balance is still in Counting status select a measuring unit to exit the counting status and enter the weighing status Note 1 The number of the articles sampled should be as much as possible but their total weight must not be greater than the maximal weighing capacity of the balance and the number of the sampled articles under maximal weighing capacity should be less than 30000 2 If no value of the previously sampled article exists in Memory lamp Counting will flash when the system enters the counting function indicating that the first sampling operation needs to be carried out in case the lamp Counting lights up it indicates that the value of the previously sampled article exists in Memory 3 The maximal known quantity to be inputted should not exceed 1 2 of the value of internal code 3 9 3 A oFF selection of AUTO POWER OFF 3 9 3 When A oFF is displayed in the table of main functions press down key TARE to enter this function Press down key SET 0 9 to select NO or YES and then press down key TARE to confirm
2. the selection NO indicates that the balance won t be powered off automatically and YES indicates that the balance will be powered off automatically if it stays at zero point for over 10 minutes 3 9 4 FILt Setting of display mode 3 9 4 When FILt is displayed in the table of main functions press down key TARE to enter this function Press down key SET 0 9 to select FILt 1 or FILt 2 or FILt 3 PAGES JADEVER http www jadever com tw JWP and then press down key TARE to confirm the selection FILt 1 indicates that the re display is slow when a weight is loaded FILt 2 indicates that the re display is a little bit faster when a weight is loaded FILt 3 indicates that the re display is fast when a weight is loaded 3 9 5 ZEro Setting of the automatic zeroing range at zero point When ZEro is displayed in the table of main functions press down key TARE to enter this function the screen will display x xE x x indicates the automatic zeroing range at zero point and it is expressed in calibration scale intervals It will be set to 0 5E 1 0E 1 5E 2 0E 2 5E 3 0E 3 5E 4 0E 4 5E and 5 0E respectively by pressing down key SET 0 9 Press down key TARE to confirm and return to the weighing status 3 9 6 bUZZEr Buzzer ON OFF when used under upper lower limits When bUZZEr is displayed in the table of main functions press down key TARE to enter this function and press down key SET 0 9 to select ON o
3. JWP Electronic waterproof weighing scale with single double display Operation Instructions Xiamen Jadever Scale Co Ltd PC JWP CONTENTS Introduction Major technical imdexes 1 esi eesase enda u ua eit edan aada sm an id dann nt eesel 2 Functions of operation keys and prompts weerreeeeeeeeeeeee 3 Operation instruction uiva dos n natsi a tada n ved na sd va narrada 4 Preparations before use eeeeeeeeneooeeoeeeoeeeooeeeeeeeeeeeeee ILA A TTT Direct Weighing as 4 Weighing without tare essssesocssscsssccoossscosesscosesoosseseeossss A Power saving TUNCHON e ici ri 5 Indication EPOC A a iS CATING pesca nites dee S Setting and using of parameters ccccccccsscccccccssscsccecsscssceesees Y Brightness ad jus hment ici ic T PRECAUTIONS o LL PROCUCE WA ar 12 PAGE1 JADEVER http www jadever com tw JWP Introduction We appreciate your using our JWP series water proof electronic balance counter with single double display and stainless steel case As a water proof electronic balance which is developed by adopting the latest technology it features high accuracy stable performance accurate weighing adequate resistance to vibration rapid display firmness and durability and convenient after sale service Multiple measures have been taken to improve water proof and moisture proof performances of the product in particular the sensor elements specially deve
4. f the former needs charging soon after the previous charging 4 2 5 Considering that the lead acid batteries are consumable and its service life depends on users application methods therefore the warranty period for batteries is only one month PAGE11 JADEVER http www jadever com tw JWP Product Warranty Client Model Instrument No Purchase date We appreciate your purchasing the product of our company In the event of any trouble by showing this service card you may enjoy services free of charge for one year commencing from the purchase date X In case of one of the following conditions you will be charged the reasonable fee for material cost or service even if the balance is still in the warranty period Please kindly understand 1 You should show the warranty to our servicemen who come to you upon your request if the warranty is lost or damaged so that the words on it became illegible you shall be charged fees 2 The balance is damaged due to negligence or maloperation on your part 3 The trouble is caused by the modification made by you unilaterally 4 The balance is damaged due to movement or transport made by purchasers after the installation of the balance 5 The balance is damaged due to natural disasters X After the expiration of the warranty period you will be charged the reasonable fee in respect to parts adjustment or calibration upon after sale service X The war
5. g 70x36x32cm 2 Functions of operation keys and prompts 2 1 Operation keys ON zeroing key for powering on and zeroing the balance Tare key for taring OFF key for powering off the balance Set numeric key for setting parameters and inputting figures SU E Es 2 2 Prompts de x xx Prompt for battery voltage It will be displayed on the screen during self verification after powering on to indicate that the current voltage of batteries is x xxV Prompt for overload It will be displayed on the screen when the weight to be weighed exceeds 100 FS 9e at the same time buzzer ticks to indicate overloading at this time the weight should be reduced bAtLo Prompt for low voltage of batteries It will be displayed on the screen after powering on if the voltage of the built in batteries is insufficient the display will resume to be normal if a weight is loaded on the balance In this case the balance may be used for a short time but it should be powered off as soon as possible and charge the batteries with the built in charger PAGE3 JADEVER http www jadever com tw JWP c End Prompt for completed charge It will be displayed on the screen in a flashing manner when the batteries are fully charged Err 0 Itindicates that the zero point of sensor exceeds the normal range and the tare should be reduced correspondingly 3 Operation instruction 3 1 Preparations before use Adjust the feet and obse
6. he ZERO lamp goes out and TARE lamp lights up then put the article to be weighed in the abovementioned container or package and the screen shows the net weight of the article Remove the article together with the container or package the screen shows the minus value of tare and ZERO lamp lights up At this time press down key TARE and the TARE lamp goes out and the zero status of gross weight resumes 3 6 Power saving function The balance will enter power saving status automatically when it stays at zero point for over 40 seconds at this time the screen will display only the last zero The screen will resume its normal display automatically when an article to be weighed is put onto the balance pan or a key is operated 3 7 Indication of power Power indicator lamp High indicates a voltage of batteries higher than 6 3V Medium indicates a voltage within 6 6 3V and Low indicates a voltage below 6V that is the power of batteries will be used up soon 3 8 Charge This balance is powered by the built in 6V 4 5Ah maintenance free hermetic lead acid batteries In case the voltage of batteries is insufficient and the balance is at its zero point the screen will show bAtLo at this time the balance may be used for the time being but the built in batteries should be charged as soon as possible Charging method open the battery door on the bottom of the balance insert the plug of inp
7. he lead seal on the bottom of balance Should any trouble occur please contact dealers or manufacturer of the balance 4 2 Precautions for application of the hermetic lead acid batteries 4 2 1 The batteries in this balance are maintenance free hermetic lead acid batteries which features low self discharge rate and long service life Its operation temperature is 10 C 40 C and its discharging and charging cycle is about 300 times at a temperature of about 20 C 4 2 2 Make sure that the connection with the negative electrode and the positive electrode is correct while replacing the batteries otherwise the batteries will be damaged and a fire may be caused The correct connection is as follows the red line is to be connected with the plug with red mark and the black line is to be connected with the plug with black mark 4 2 3 The batteries should be recharged in a timely manner when its power is run out the indication of low power appears on the screen In case a balance will be left idle for a long time its batteries should be fully charged before its storage and should be charged at least once every three months 4 2 4 The capacity of batteries will decrease gradually along with the increase of charging discharging times that is the operation time of recharged batteries will become shorter and shorter which reflects the characteristics of the rechargeable batteries The original batteries should be replaced with new ones i
8. loped by our company are adopted on which series treatments have been done to the anti corrosive and anti overloading performances of the sensors This greatly lengthens the service life of sensors Therefore besides applications in general retail of goods and quantitative packing this product is especially suitable for applications under conditions of high humidity such as food and aquatic products processing This product has been awarded multiple national patents Please carefully read the Operation Instructions before using it 1 Major technical indexes 1 1 Basic parameters Model J WP 600 JWP 1 5K JWP 3K J WP 6K JWP 15K JWP 30K Parameter Item Max weighing 600g 1 5kg 3kg 6kg 15kg 30kg capacity Min weighing 20e capacity Verification scale 0 2g 0 5g 1g 2g Sg 10g interval e Display scale 0 1g 0 2g 0 5g lg 2g Sg interval dl Display scale 0 05g 0 1g 0 2g 0 5g lg 2g interval d2 Max taring 100 of Max weighing weight capacity Accuracy grade UN Dimension of 19x23 Cm balance pan PAGE2 JADEVER http www jadever com tw JWP 1 2 Operation temperature 5 35 C 1 3 Storage temperature 25 50 C 1 4 Power supply Built in 6V4 5Ah hermetic lead acid batteries charged by built in charger 1 5 Net weight 4kg set 1 6 Package 4 sets box 20k
9. mit lamp Conformity will light up do not flash When m lt the value of lower limit lamp Lower Limit will flash Note no alarm will be sent before the weight display becomes stabilized and none of the above three lamps will light up at this time 3 9 2 UnltS Selection of measuring units 3 9 2 1 When UnltS is displayed in the table of main functions press down key TARE to enter and display the measuring unit currently used all units will be displayed one by one in turns by pressing down key SET 0 9 sequentially Press down key TARE to confirm the desired unit displayed The existing units include H9 Kg 9 g PcS counting Lb Lb decimal pound and Lb oZ pound ounce 3 9 2 2 Counting function 1 Press down key TARE to enter this function when PCS is displayed on the screen 2 Hold down key On ZERO the screen will resume its zero status after displaying CoUnt 3 Put the sampled article of known quantity on the weighing pan and the value of internal code of this article will be displayed on the screen 4 Press down key TARE after the display becomes stabilized and the figure at the top digit will flash indicating to input the known quantity 5 The flashing figure at the digit will be increase by 1 every time key SET 0 9 1s pressed down for once 6 When the figure reaches the desired value press down key TARE to confirm at the same time the figure at the next digit will
10. nfirm the selection users will enter the setting status of weight at upper lower limits At this time Lower Limit lamp flashes and the value to be set at the top digit will flash concomitantly indicating that the figure at this digit may be set The value will be increased by 1 every time when key SET 0 9 is pressed down for once When the desired figure at this digit is displayed confirm by pressing down key TARE and users begin setting the figure at the next digit with the same procedures as above The setting failure at a digit indicates that the setting range is exceeded and users should press down key TARE to begin setting the next digit After the completion of the above setting the system will exit the setting status of lower limit and enter the setting status of upper limit automatically Lamp Upper Limit will flash at this time the upper limit may be set with the same procedures as that for lower limit setting The system will return to the weighing status automatically after the setting completes PAGE6 JADEVER http www jadever com tw JWP 3 9 1 3 The set value of upper limit must be greater than that of lower limit otherwise OFF will be displayed upper lower limits will be closed and the system will be exited 3 9 1 4 Alarm indication m is the weight of an article When m gt the value of upper limit lamp Upper Limit will flash When the value of lower limit lt m lt the value of upper li
11. press down key TARE to confirm the selection YES indicates that the values will be displayed on both sides and NO indicates that the values will be displayed only on one side no display on the side facing clients this function helps to save power 3 10 Brightness adjustment Hold down key On ZERO to display LC 1 under the weighing condition press down key SET 0 9 to select LU 1 or LU 2 and press down key TARE to confirm the selection LU 1 indicates the power saving status recommended and LU 2 indicates a condition for brighter diaplay 4 Precautions 4 1 Common precautions 4 1 1 Please carefully read the operation instruction before using the balance so that you may understand more about this product for your convenient use 4 1 2 This balance is a measuring instrument subject to mandatory verification therefore it should be regularly sent to the authority responsible for the verification to maintain its accuracy 4 1 3 Overload is strictly forbidden Never throw a heavy substance at the balance or impact it heavily Any part of the balance damaged due to the above maloperations is out of our warranty 4 1 4 Never let the balance contact chemicals such as solvents to avoid corrosion 4 1 5 Keep the balance clean and no foreign matter is allowed to exist around the balance pan otherwise the accuracy of balance may be affected PAGE10 JADEVER http www jadever com tw JWP 4 1 6 Users must not open t
12. r oFF On indicates that the buzzer will be used to tick when the balance is used under upper lower limits and oFF indicates that no tick will be send out Press down key TARE to conform the selection 3 9 7 d Selection of scale intervals When d is displayed in the table of main functions press down key TARE to enter this function press down key SET 0 9 to select scale intervals and press down key TARE to confirm the selection Each weighing operation has 3 scale intervals and the re display of the article weight will be slow in case a smaller scale interval is selected 3 9 8 on rA Selection of powering on range When on rA is displayed in the table of main functions press down key TARE to enter this function press down key SET 0 9 to select 20 or 100 and press down key TARE to confirm the selection 20 indicates that the powering on range is limited within 20 and 100 indicates that no limit is imposed on the powering on range In case the zero point upon PAGE9 JADEVER http www jadever com tw JWP powering on is greater than 20 of the maximal weighing capacity Err 0 and Err 04 will be displayed upon powering on and the tare should be reduced to less than 20 of the maximal weighing capacity 3 9 9d dP Selection of single double side display When d dP is displayed in the table of main functions press down key TARE to enter this function Press down key SET 0 9 to select YES or NO and then
13. ranty is invalid without stamp of the dealer or the purchase date being left unfilled PAGE12 JADEVER http www jadever com tw JWP PAGE13 JADEVER http www jadever com tw
14. rve the level to make the balance located at a level plane 3 2 ON OFF 3 2 1 ON Press down key On ZERO to power on the balance the buzzer ticks and the software version is displayed on the screen and then dc x xx the figure indicates the voltage of batteries is displayed on the screen then the system begins self verification All figures from 9 to 1 will be displayed in counting down manner and the screen shows the maximal weighing capacity of this balance and then zeroing will be displayed on the screen and the zeroing lamp lights up showing that the balance enters the weighing status 3 2 2 OFF Press down key OFF to stop the balance 3 2 3 Auto power off In case the balance is set to Auto power off it will be powered off automatically if it stays at zero point for over ten minutes refer to 3 9 3 3 2 4 Power off at low voltage The balance will be powered off forcibly when the voltage of batteries 1s lower than 5 6V 3 3 Zeroing In case an article with tare shows on the screen a value that is not greater than 4 of Max weighing capacity press down key On ZERO to make the screen show zero and ZERO lamp lights up 3 4 Direct weighing PAGE4 JADEVER http www jadever com tw JWP Put an article on the balance pan and the screen will directly show the weight of the article 3 5 Weighing without tare First put a container or a package on the balance pan press down key TARE the screen shows zero t
15. ut lead of the charger into a socket connected with the municipal power supply The power indicator lamp on the main panel will flash to indicate that the charging is underway It will take about 12 hours to complete the charging it is unnecessary to power on the balance for charging the batteries 3 9 Setting and using of parameters Hold down SET 0 9 for 3 seconds to enter the setting status the screen will display the table of main functions and press down sequentially SET 0 9 to display various PAGES JADEVER http www jadever com tw JWP items of the main functions rAngE setting of upper and lower limits UnltS selection of measuring units A oFF selection of AUTO POWER OFF FILt setting of display mode ZEro setting of the automatic zeroing range at zero point bUZZEr buzzer ON OFF when used under upper lower limits d selection of scale interval on rA selection of powering on range d dP selection of single double side display While setting parameters key SET 0 9 is used for selection purpose and key TARE for confirmation 3 9 1 rAngE Setting of upper lower limits 3 9 1 1 When rAngE is displayed in the table of main functions press down key TARE to begin the setting of upper lower limits press down key SET 0 9 to select On oFF to open or close upper lower limits and press down key TARE to confirm the selection 3 9 1 2 By selecting On and pressing down key TARE to co
Download Pdf Manuals
Related Search
Related Contents
EXSYS USB 1.1 to 8S Serial RS-232 ports Tote Vision LCD-1042TS User's Manual Basic Panels 2nd Generation télécharger le fichier PDF. - Communauté de communes du Pays de Whirlpool AKR 769 GY Inter-Tech G-129 Sunny Data Control - SMA Solar Technology AG Stationary and Portable Spas Important Safety Information Copyright © All rights reserved.