1. C ZAM DEP SELECT KEYS C ZAM DEP SELECT READ LOCAL KEY FROM DCC TYPE IN TAG NO USE 4 button KEY DEP_DMK 04000000 SELECTED KEY ENTER YOUR PIN PIN ENTRY OK READING KEY PART READ FROM DCC OK REMOVE DCC REMOVE DCC INSERT STO DCC INSERT STORAGE DCC SEARCHING ENTER YOUR PIN PIN ENTRY OK READING KEY PART READ FROM DCC OK REMOVE DCC REMOVE DCC INSERT STO DCC INSERT STORAGE DCC SEARCHING ENTER YOUR PIN PIN ENTRY OK READING KEY PART READ FROM DCC OK REMOVE DCC REMOVE DCC KEY RECONSTRUCTED OK KEY READ FROM DCC OK C ZAM DEP SELECT KEYS C ZAM DEP SELECT SEND KEYS TO DEP C ZAM DEP SELECT SEND ONE KEY TO DEP KEY DEP DMK SELECTED SENDING KEY SENT TO DEP OK banksys Terminals amp Card Applications Page 8 9 DEP Quick Load Guide 03 00 Classification Restricted ON THE DEP HANDLER SUPERVISION SELECT DEPx RESTORE KEYS SELECT KEY FILE DAT RESTORING b ERASE A KEY FROM DEP SELECTED KEY DMK 4 7 LOAD REQUIRED CAPABILITIES IN DEP CRYPTO MODULE IEPP C_SCM LOAD C_PUR_PER CARD C ZAM DEP SELECT ACTIVATE DEP CAPABILITY CAPABILITY xxx USE UP DOWN AND OK SELECTED CAP INSERT STO DCC
2. 6 4 5 SOFTWARE LOADING 6 4 6 KEY BACKUP 0 7 4 7 LOAD REQUIRED CAPABILITIES IN DEP CRYPTO 40 1 8 4 8 POST PROCESSING a A a EEE 8 9 banksys Terminals Card Applications Page 4 9 DEP Quick Load Guide 03 00 Classification Restricted 2 SCOPE OF THE DOCUMENT The DEP Quick Load Guide describes step by step the procedure how to load a DEP PCI with software and keys This guide cannot be generalized because the procedure depends on some definitions of the Customer s Security Officer such as secret sharing The guide is written as an example and should thus be adapted when necessary A complete and generic procedure can be found in the document DEP Customer 5 Security Officer s Guide See the manual DEP C ZAM DEP User Manual for more information about all the C ZAM DEP actions 3 REFERENCES This document contains a reference to other documents about the DEP This paragraph gives a list of all the documents referred to e DEP NT DEP Handler Supervision User Manual e DEP Customer s Security Officer s Guide e DEP C ZAM DEP User Manual There are no references made to the following documents but they
3. INSERT DCC STORAGE ENTER YOUR PIN PIN ENTRY OK READING CAP PART READ FROM DCC OK REMOVE DCC REMOVE DCC CAP READ FROM DCC CHOOSE TYPE OF LIMITATION UNLIMITED CAPABILITY OK ACTIVATING CAPABILITY ACTIVATED OK 4 8 POST PROCESSING SWITCH THE DEP CRYPTO MODULE OFF LINE banksys Terminals amp Card Applications Page 9 9 DEP Quick Load Guide 03 00 Classification Restricted 4 9 REMARKS e The RESTORE BANKSYS AUTHORITY and RESTORE CUSTOMER AUTHORITY should be done once per C ZAM DEP e When closing the C ZAM DEP with the following procedure all the information is kept inside the C ZAM DEP also DMKs C ZAM DEP SELECT SPECIAL FUNCTIONS C ZAM DEP SELECT SAVE DATA TERMINATE This function should be used carefully for LIVE C ZAM DEPs UNDER SUPERVISION OF THE CUSTOMER S SECURITY OFFICER e When closing the C ZAM DEP with the following procedure all the data is lost inside the CZAM DEP such as capabilities keys This means that this data should be reloaded when using the C ZAM DEP C ZAM DEP SELECT SPECIAL FUNCTIONS C ZAM DEP SELECT TERMINATE CZD SESSION
4. could be useful to understand this document e DEP Introduction to DEP e DEP General Architecture e DEP Glossary 4 DEP QUICK LOAD GUIDE 4 1 PRELIMINARY NOTE Make sure that the on the module you want to work with the battery is set on It can be done with the DEP Handler Supervision via DEPx Reset Functions Set Battery On see document DEP NT DEP Handler Supervision User Manual for more information SWITCH THE DEP CRYPTO MODULE OFF LINE banksys Terminals amp Card Applications Page 5 9 DEP Quick Load Guide 03 00 Classification Restricted 4 2 RESTORE BANKSYS AUTHORITY BY USING THE BANKSYS DCC C ZAM DEP SELECT BANKSYS AUTHORITY C ZAM DEP SELECT RESTORE BANKSYS AUTHORITY CHOOSE MODE USE M BUTTON TST TEST LIV LIVE ENTER CUSTOMER ID see on DCC READ CZD LISTS FROM DCC OK INSERT DEF DCC INSERT DCC DEFINITION LIST READING LIST READ FROM DCC OK REMOVE DCC REMOVE DCC GET KEY KM_ AUTH _BKS OK INSERT STO DCC INSERT DCC STORAGE SEARCHING ENTER YOUR PIN PIN ENTRY OK READING KEY PART READ FROM DCC OK REMOVE DCC REMOVE DCC KEY RECONSTRUCTED OK BKS AUTHORITY RESTORED OK STOP STOP STOP C ZAM DEP SELECT CAPABILITIES C ZAM DEP SELECT ACTIVATE CZD CAPABILITY CAPABIL
5. Haachtsesteenweg 1442 1130 Brussels Terminals 8 Card Applications Belgium end to end transactions DEP Documentation DEP Quick Load Guide Version 03 00 Classification Restricted banksys Terminals Card Applications Page 2 9 DEP Quick Load Guide 03 00 Classification Restricted Version Management Report 03 00 11 07 2005 COPYRIGHT NOTICE The information contained in this document is subject to change without notice banksys assumes no responsibility for any errors or omissions that may appear in this document The contents of this document must not be reproduced in any form whatsoever by or on behalf of third parties without prior written consent of banksys banksys Terminals Card Applications Page 3 9 DEP Quick Load Guide 03 00 Classification Restricted 1 TABLE OF CONTENTS 1 TABLE OF CONTEN Ds ena DU ke ha o kun VE c D k y 3 2 SCOPE OF THE DOCUMENT 4 3 REFERENCES 554 5 555x5 49030 5iy 5256 xodana 200005 u n 00 baw a 0ya U KEN ON AGE aeae 4 4 DEP QUICK LOAD GUIDE cities isla 4 AV SPREBIMINARY Sais in oles SE dc Sot AT yay SRDS RAKE 4 4 2 RESTORE BANKSYS AUTHORITY BY USING THE BANKSYS DCC eee cece 5 4 3 RESTORE CUSTOMER AUTHORITY BY 05101411 5 4 4 READ REQUIRED KEY TAGS FROM DCC 481
6. ITY CAP_CUST_AUTH USE 4 AND OK SELECTED CAP INSERT STO DCC INSERT DCC STORAGE ENTER YOUR PIN PIN ENTRY OK READING CAP PART READ FROM DCC OK REMOVE DCC REMOVE DCC CAP READ FROM DCC CAPABILITY ACTIVATED OK STOP STOP STOP 4 3 RESTORE CUSTOMER AUTHORITY BY CUSTOMER C ZAM DEP SELECT CUSTOMER AUTHORITY C ZAM DEP SELECT RESTORE CUSTOMER AUTHORITY GET KEY KM_AUTH_CUST OK gt INSERT STO DCC INSERT DCC STORAGE SEARCHING ENTER YOUR PIN PIN ENTRY OK READING KEY PART READ FROM DCC OK REMOVE DCC REMOVE DCC KEY RECONSTRUCTED OK banksys Terminals amp Card Applications Page 6 9 DEP Quick Load Guide 03 00 Classification Restricted CUST AUTHORITY RESTORED OK C ZAM DEP SELECT CUSTOMER AUTHORITY CONNECT NOW C ZAM DEP TO DEP CRYPTO MODULE C ZAM DEP SELECT CUSTOMER INIT DEP INITIALIZING DEP INITIALIZED OK 4 4 READ REQUIRED KEY TAGS FROM DCC LIST C ZAM DEP SELECT DEFINITION LISTS C ZAM DEP SELECT READ LISTS FROM DCC INSERT DEF DCC INSERT DCC LIST READING LIST READ FROM DCC OK REMOVE DCC REMOVE DCC 4 5 SOFTWARE LOADING OPEN WIN NT EXPLORER SELECT DEPIAPPLICATIONS OPEN THE lt SOFTWARENAME gt SAC COPY THE
7. SWAC CORRESPONDING TO THE CUSTOMER ID AND MODE USE COPY PAST FUNCTION OF WINDOWS ONLY C ZAM DEP SELECT CAPABILITIES C ZAM DEP SELECT ACTIVATE DEP CAPABILITY CAPABILITY STD_SW_LOAD 05000300 USE UP DOWN AND OK SELECTED CAP INSERT STO DCC INSERT DCC STORAGE ENTER YOUR PIN PIN ENTRY OK READING CAP PART READ FROM DCC OK REMOVE DCC REMOVE DCC CAP READ FROM DCC CHOOSE TYPE OF LIMITATION UNLIMITED CAPABILITY OK ACTIVATING CAPABILITY ACTIVATED OK ON THE DEP HANDLER SUPERVISION SELECT DEPx LOAD APPLICATION SELECT lt SOFTWARENAME gt HEX FILE PASTE THE SWAC USE COPY PAST FUNCTION OF WINDOWS ONLY LOADING READ STATUS banksys Terminals amp Card Applications Page 7 9 DEP Quick Load Guide 03 00 Classification Restricted 4 6 KEY BACKUP LOADING C ZAM DEP SELECT CAPABILITY C ZAM DEP SELECT ACTIVATE DEP CAPABILITY CAPABILITY C_SAVE_KEYS 05000000 USE UP DOWN AND OK SELECTED CAP INSERT STO DCC INSERT DCC STORAGE ENTER YOUR PIN PIN ENTRY OK READING CAP PART READ FROM DCC OK REMOVE DCC REMOVE DCC CAP READ FROM DCC CHOOSE TYPE OF LIMITATION UNLIMITED CAPABILITY OK ACTIVATING CAPABILITY ACTIVATED OK STOP STOP STOP