1. Richter Optica info richter optica com Instructions for S6 BL S6 TS S6 SPS S6 ILST Models Trinocular port for c mount adapter Zoom Knob Diopter adjustable eyepieces Magnification locking screw Focusing Knob LED Lights Separate light intensity control switches for reflected amp transmitted light Zoom Knobs Trinocular port for Focus Knobs C Mount Adapter Head locking screw Ring Light Attaches Here 56 15 Stage Clips Intensity Controls Base nn Track Stand _ Focusing Knob Focusing Holder Clamp _ gt Built in Ring Light Adapter Magnification Adjustment Head Locking Screw Auxiliary Lens Attachment LED Lights Glass Stage Plate S6T ILST On Off Switch RICHTER H TER ptica CA Thank you for your purchase of a Richter Optica S6 stereo microscope The information in this manual is provided to answer most questions that can arise when operating your microscope and to help you avoid unneccesary maintenance expenses in the future Based on your microscope purchased the stand may look slightly different Please carefully read instructions before operating microscope Nomenclature used to describe components and controls are identified on opposite page UNPACKING Do not discard styrofoam container or packing materials until you are sure shipment is complete and undamaged retain stryrofoam ship
2. While firmly holding focusing holder containing viewing head with one hand loosen locking knob located on back of focusing holder so that head can move freely up or down on post While looking through microscope move viewing head up or down on post until object can be seen in approximate focus Tighten focusing holder locking knob Position the support collar under the focusing block and tighten locking knob on support collar It is not necessary to make this adjustment every time you change objects to be viewed so long as the different objects are of Diopter adjustment ring Diopter adjusiment ring similar thickness or height an e On models with lighted post stands the up down movement of the viewing head is limited to the traverse permitted by the regular focusing knobs f Both eyepieces have a knurled diopter adjustment ring Rotate the diopter until the zero 0 lines up with the notch on the diopter g Adjust zoom control to the highest magnification by aligning the number 4 5 on the zoom knob h While looking through the right eyepiece with one eye rotate focusing knob until specimen comes into sharp focus through the right eyepiece i Adjust zoom control knob to the lowest magnification j Adjust the right diopter until the image is sharp Do not change the focusing knob position Repeat to adjust the right diopter k The image should now be sharp throughout the zoom power range RICHTER
3. ard on the focusing block The tension adjustment collar is located between arm and focus knob on left side of microscope when the stage is facing towards you With a jewelers type screwdriver loosen slotted set screw located on knurled surface of the tension adjustment collar Turn collar clockwise to tighten tension counter clockwise to loosen tension After adjusting tighten set screw to lock collar into place NOTE Itis recommended that you leave the tension as loose as possible for ease of focusing yet not so loose that it permits the head of the microscope to drift downward from its own weight and cause the microscope to drift out of focus TROUBLESHOOTING Problem OPTICAL SYSTEM Too Bright Dark Dirt in Field of View Double Images Unclear Image Images Blurs on Zoom FOCUSING UNIT Focusing Knob is Stiff Microscope Head is Falling ADJUST MAGNIFICATION Zoom Control Knob Will Not Turn Reason for Problem Brightness degree is not set appropriately Dirt on Specimen Dirt on Eyepieces Dirt on Objective Lens Dirt on Stage Incorrect Interpupillary Distance Incorrect Diopter Setting Two Different Magnification Eyepieces Dirt on Objective Lens Incorrect Diopter Setting Incorrect Working Distance or Focusing Setting Focusing Knob Tension is Too Tight Focusing Knob Tension is Too Loose Magnification lock may be Activated Solution Adjust rheostat intensity control Clean the sampl
4. e Clean the Eyepieces Clean the Objective Readjust Diopters Check Working Distance amp Focusing Loosen tension Tighten tension Loosen Magnification Lock Screw on Front of Microscope Body Loosening amp Tightening focusing tension depends on the microscope stand you have The BL stand adjusts the focus tension by holding both focus knobs left amp right and while holding the left steady rotating the right knob The ILST microscope stand focus is adjusted similarly by holding both knobs and rotating the right knob forward or back to tighten or loosen RICHTER prica EYEPIECE RETICLE INSTALLATION The Richter Optica S6 stereo microscope widefield high eyepoint 10x and 15x eyepieces both accept a 25mm diameter reticle To install the reticle 1 Remove the eyepiece from the eyetube and turn the eyepiece upside down 2 Twist out and remove the threaded retaining ring from the bottom of the eyepiece 3 Place the eyepiece reticle in the eyepiece with the inscription side facing the front of the eyepiece 4 Screw the retaining ring back into the bottom of the eyepiece to hold the reticle in place RICHTER prica S6 STEREO MICROSCOPE MAGNIFICATION The Richter Optica S6 stereo microscope can acheive different magnifications based on the eyepieces and auxiliary lenses used Refer to the chart below in order to select the proper eyepiece and auxiliary lens accessories to meet your needs Eyepieces Aux
5. erica MAINTENANCE WARNING For your own safety turn switch off and remove plug from power source before maintaining your microscope If the power cord is worn cut or damaged in any way have it replaced immediately to avoid shock or fire hazard 1 Optical Maintenance a Do not attempt to disassemble any lens components Consult a microscope service technician when any repairs not covered by instructions are needed b Prior to cleaning any lens surface brush dust or lint off lens surface using a camel hair brush You can also use an ear syringe or canned compressed air sold by computer stores C To clean eyepiece lenses do not remove from eyepiece tube Clean only the outer lens surface Breathe on lens to dampen surface then wipe with lens paper or use a cotton swab moistened with distilled water Wipe lenses with a circular motion applying as little pressure as possible Avoid wiping dry lens surface as lenses are scratched easily If excessive dirt or grease gets on lens surfaces a small amount of Windex can be used on a cotton swab or lens tissue To clean objective lenses do not remove objectives from microscope Clean front lens element only following same procedure 2 Mechanical Maintenance The only mechanical adjustment the microscope might require is the tension of the focusing mechanism This has been adjusted at the factory but over the course of time it may loosen and cause the head of the microscope to slip downw
6. iliary Working Widefield 10x Widefield 15x Widefield 20x Lens Distance Total Field Size Total Field Size Total Field Size Magnification mm Magnification mm Magnification mm 3 5x 22 5x 57 1 8 9 5 25x 33 75x 42 9 6 7 28 6 4 4 28 5 4 4 10 5x 67 5x 21 4 3 3 14x 90x 14 3 2 2 10 5x 67 5x 19 3 15 75x 101 25x 14 2 2 2 21x 135x 9 5 1 5
7. ping container to store your microscope when itis not in use Remove all tape and packing material used to protect microscope during shipment Make certain lens surfaces do not come in contact with dirt fingerprints or oil Damage of lens surfaces occur when they come in contact with such contaminants and image quality is reduced ASSEMBLY Eyeshields Remove eyepiece covers Remove objective Eyepieces cover Body Upper Light Source Wire Power cord OPERATION Illumination only for S6 BL S6 ILST amp S6 TD LED Models a Before operating the microscope adjust the intensity controls located on each side ofthe base to the minimum position This should be done prior to each time light is turned on or off Failure to do so will signifcantly shorted the life of the bulb b Make certain that the main voltage of your microscope corresponds to the voltage of your power outlet either 120v or 220v Insert microscope power cord into power outlet C The S6 on lighted LED stand includes a glass stage plate This plate is ideal for viewing transparent specimen slides or specimens that are thin enough for light to pass through them insect wings plant leaves etc Alternate black white contrast plates can be used when viewing opaque objects or for dissecting To remove the stage plate on ILST stand loosen locking set screw on front of base by unscrewing it to the left d For models S6 BL amp S6 ILST there are rocker swi
8. tches on the base of the microscope These switches are used to turn the light on off The rheostat control knobs will not work if the rocker switch is in the off position Interpupillary Adjustment This will permit each user to adjust the spacing between eyepieces to accommodate distance between their eyes While looking through the microscope eyepieces with both eyes grasp eyepiece tube housings with both hands and rotate them moving eyepieces apart or together until a full field of view is observed and the images blend into one Interpupillary distance is now corrected for your own inter ocular distance and does not require further adjustment unless another user changes the adjustment Focusing a Adjust zoom control knobs located on both sides of the head so that the lowest magnification number 0 7 is positioned at the white notch index on head Lower magnifications have larger fields of view making it easier to position and locate area to be viewed b Place object on stage plate RICHTER Err ca Focusing Continued C Position focusing knobs in the center of focusing range d Use included allen key to lock and set magnification if desired d On mounted post models the height of the viewing head can be adjusted up or down on the post in order to focus on different sized objects Loosen the locking knob located on the locking support collar allowing the support collar to slide down to bottom of post