Home
Switchboard - HomeSystems Legrand
Contents
1. 5 Press to exit the menu Modify Meo ciate tay a i 5 ZN Select the contact to modify and press ZT OK Apartment 2 2 Apartment 3 3 A quick search bar is also present where T F A m the user can enter the details of the Rae Ca required contact using the keypad AD anr fin Gia i 5 EN e eh loa ane a o 6 Pe Oracle imesh baer 7 A Selectthe parameter that needs changing he eee 0 Use the keypad to enter the new value or description ESOrGulkc s Avde dive Ss O Description lt Cancel the entry in case of mistake alecs o Press OK to confirm Fier or O A eee aay j A Move the cursor to Save V Save Press OK to save the changes made 15 4 Settings Z N WARNING The switchboard makes direct calls using the logic addresses Delete Delete pa A Move the cursor to the contact to delete i 0 WY Apartmen 2 OK Press OK to delete the contact Apartments 3 Apartment 4 4 Apartment 5 5 5 Press to exit the menu A pra tine i ia 6 6 AD fallen eX Aa A 1 16 Switchboard 4 4 Time bands For each day of the week it is possible to set up to 3 day start and night start time bands upon which the switchboard will automatically switch from one status to the other NOTE This mode is active when the Day Night function of the configuration menu is set to auto matic see User Manual 4 gt Select the Time Bands function Press OK to display the screen used to enter the time bands rime Bands
2. e e Press OK repeatedly to select Monday the day of the week as Day Start rane oe Select Weekday to set the time bands for every day from Monday to Friday at Bee aie A aS ai thesame time F 3 Diaa t ann AN l Select the desired time band sate None Sieur Ape VW ENS Ie VRS ieee EER Press OK to highlight the Ona S aoe Valen oenange Use the keypad to enter the desired time use the key to delete wrong entries Press OK twice to delete the selected time band and all subsequent ones Press OK to confirm and con tinue with the subsequent time bands Press to exit the menu 17 btiicine 4 Settings 4 5 Automations This function can be used to configure up to 5 entrance panels so that the corresponding door locks can be released when no calls are active from the entrance panel 4 gt Select the Automation function Press OK to access the menu A 4 gt Select the parameter to set Press OK to highlight the entry field Use the keypad to enter the desired value or description Press OK to confirm Press to exit the menu 18 Switchboard 4 6 Function key setup It is possible to configure each of the 12 keys of the dedicated keypad to perform a certain function gt Select Function Keys Setup VY Press OK to access the menu Press OK repeatedly to se lect the key to configure F1 to F12 Select Function Press OK repeatedly to select the function
3. the content of the Description field will be displayed Block Floor Apartment for each contact the content of the fields Block Floor Apartment will be displayed For more information see the Modify Contact section 23 4 Settings 4 9 Change password This function is used to change the password for access to the Installation setup section The de fault password is 12345 lt gt Select the Change Password function VW Press OK to confirm Chandge Password v Enter the new password using the keypad max 5 digit number Press repeatedly to delete AMreww TP des o word entries made Press OK to confirm and exit the menu 1 Wew Pass woro Sto red 24 Switchboard 5 Advanced configuration As an alternative to the menu setup it is also possible to configure the switchboard from the PC using the TiSwitchBoardDevice software found in the CD supplied WARNING Some functions like the creation of the directories and the management of the bells can only be performed using the software 5 1 Connection to the PC To transfer the configuration performed using the TiSwitchBoardDevice software or to update the Firmware connect the switchboard to the PC using an USB miniUSB cable adl lt SSS lt SS SSS SSS SS SSS SSS S55 To enable communication the switchboard must be powered 25 6 Troubl
4. used to receive and forward audio video calls and to manage alarms both inside the individual apartments of the 2 wire digital video door entry system and in common areas The unit has a 7 LCD colour display icon menu menu navigation keys and video door entry system function keys The main functions of the switchboard are the following e call an apartment handset e receive calls from Entrance Panels and forward them if necessary to the various apartment handsets e receive standard or alarm calls from the apartments e control the electrical door locks of the Entrance Panels e switch the staircase lights on e activate a relay e switch on Entrance Panels or a cameras monitoring e cycle through the cameras surveillance The switchboard also provides the following e DAY NIGHT management with the possibility of only enabling the switchboard functions during certain time bands which can also be set by the user e a CALL LIST saving all the unanswered calls received from apartment handsets e an HANDSET DIRECTORY and an ENTRANCE PANEL DIRECTORY Their programming ensures easy identification of the calling apartment or entrance panel INTEGRATIONS Communication From the main menu screen it is possible to access a range of video door entry system settings and functions The keys also enable the activation of DIRECT CALL intercommunicating call to an apartment handset ACTIVATION direct activation of the door lo
5. 346310 Switchboard Installer manual Switchboard Contents 1 Introduction 4 1 1 Warnings and recommendations 4 1 2 What s in your box 4 2 Description 5 2 1 Main functions 5 2 2 Front view 6 2 3 Video door entry system function keys 7 2 4 Navigation keys 7 2 5 Back view 8 3 Installation 9 4 Settings 10 4 1 Handset IU D N 12 Function 12 4 2 Slave handset IU 13 4 3 Modify contact 14 44 Time bands 17 4 5 Automations 18 4 6 Function Key Setup 19 4 7 Alarm Setup 20 4 8 Configuration 21 4 9 Change password 24 5 Advanced configuration 25 5 1 Connection to the PC 25 6 Troubleshooting 26 7 Appendix 27 1 Introduction 1 1 Warnings and recommendations Before proceeding with the installation we recommend that you read the content of this manual very carefully The warranty will automatically become void in case of negligence improper use tampering by unauthorised personnel Therefore the Switchboard must only be installed indoors must be kept away from water drips and sprays must only be used in conjunction with BTicino 2 wire digital video door entry systems 1 2 What s in your box In your box you will find e Switchboard e CD with the manuals gog Switchboard 2 Description 2 1 Main functions Once correctly configured using the TiSwitchboardDevice program in addition to perfor ming the standard functions door lock release and video monitoring the switchboard can also be
6. ck associated to the entrance panel DIRECTORY display of the handset entrance panel and switchboard directories CAMERA CYCLICAL SELECTION direct activation of the camera associated to the entrance panel and cycling through the cameras present on the system HANDSFREE activation of handsfree mode Alarms It gives the possibility of receiving and managing alarms from apartment or common areas NOTE The switchboard is unable to manage the calls from riser Entrance Panels EP i e entrance panels installed downstream interface 346851 Calls from riser Entrance Panels EP will therefore always be forwarded directly to the Handsets IU Internal Units 2 Description 2 2 Front view 3 A o1 CO N O 1 Handset 2 Colour LCD display it displays the menus for the operation and programming functions It shows the images recorded from the entrance panel and from other cameras 3 Handsfree microphone Navigation key it s used to navigate through the menu and confirm the selections made OK key Cancel key Direct call key Door lock key Directory key Entrance panel activation and cycling key 10 Handsfree key 11 Active alarm LED 12 Switchboard status LED 13 Alphanumeric keypad 14 Configurable function keypad 15 Handsfree loudspeaker ON OA UI i Co Switchboard 2 3 Video door entry system function keys d Direct call key To send the call to the desire
7. d apartment handset after entering the associate directory extension Door lock key When the connection is activated the door lock of the calling Entrance Panel opens When idle the door lock of the associated Entrance Panel opens Directory key It displays the handset entrance panel and switchboard directory screen Entrance Panel Cycle mode activation It switches the associated Entrance Panel on and enables cycling through any other Entrance Panels or cameras present Handsfree key It activates the handsfree mode excluding the handset or vice versa 2 4 Navigation keys o Q9 OK key It switches the monitor on It provides access to the menu it confirms the selection made Keys AV 40 They can be used to scroll horizontally or vertically through the menu items In some submenus they can be used to change the values set C key To Return to the previous screen if the user is already on the first screen it can be used to turn the display off N 2 Description 2 5 Back view Mini USB connector for connection to the PC End of line ON OFF micro switch Connection to the BTicino 2 wire digital system BUS Additional power supply connector 1 2 wu F amp F WwW N Optional siren contact connector Switchboard 3 Installation 1 Remove the cover from the base 2 Insert the cable in the appropriate slot 3 Connect to the bus and to the additional power supply if re
8. eshooting Problem check that the switchboard is correctly wired No image appears when the Entrance Panel and configured Cycling key Laer a is pressed the audio video channel may be busy wait for it to become free and try again No control is performed when the Door check that the switchboard is correctly wired Lock key is pressed and configured check that the switchboard is correctly wired and configured check that the bell volume has not been turned right down The switchboard does not ring speak at a maximum distance of 50 cm from the handsfree microphone reduce the volume of the entrance panel microphone and increase the volume of the EP speaker From the entrance panel it is difficult to hear who is speaking 26 Switchboard 7 Appendix TECHNICAL DATA from SCS BUS 19 27 V Power supply from 12 18 27V Absorption Max from 20 mA A V connection at the minimum operating voltage BUS with additional power supply 5 mA in stand by Absorption Max from 450 mA A V connection at the minimum operating voltage BUS without additional power supply 35 mA in stand by Operating temperature 0 40 C Absorption Max 300 mA from 1 2 Note about the LCD screen The LCD screen has been produced using state of the art high precision technology It may however happen that up to 5 small black and or red blue or green dots will appear on the LCD screen This is normal and d
9. handset temporarily answer any calls received by the switchboard and to configure the corresponding address 4 gt Select the slave handset function VY Press OK to access the menu To enable or disable the slave handset A Select the desired position OK Press OK repeatedly to make the selection To change the address Select the desired position Press OK to highlight the value to change gt 2 dD A VY Change the value Press OK to confirm Press to exit the menu O lt 13 4 Settings 4 3 Modify contact It can be used to create change or delete the contacts in the various directories lt gt Select the Modify Contact function Press OK to access the menu v Changer Conia e Q u Address Book Press OK repeatedly to select the desired wares Ee ma directory v Change Coniaci u Address Book 4 Select the desired action Create Modify Delete aa x l Press OK to confirm Create 14 Switchboard Create Move the cursor to the existing parame LA rn n i i j te akru l ters in succession 2 lt gt ene a aaa 0 Press OK to highlight data for which the Logic Address value must be entered Bere ce filo ai oun Use the keypad to enter the new value s or description Balko Crk O Press OK to confirm Foron O A E A 0 ZN Once the necessary details have been YW entered move the cursor to Save Save OK Press OK to save the new contact
10. m Select Local address 21 gt ocal Address main Associated Switcnb Main BP Gi o c a Address Gs Associated EP Lisi a ASS S 0ve I ated Camera Activated Alphanumeric Address Book Enatish v 22 4 Settings A ai Select the desired item V OK Press OK to highlight the value to change Use the keypad to change the value Press OK to confirm NOTE If only one switchboard is present this must be configured as primary switchboard with local address 0 When more than one switchboard are present any switchboard can be set as primary only one for each system or secondary local address 1 to 15 In this case enter the address of the associated primary switchboard in the appropriate field For the list of the associated Entrance Panels on which the transfer from Day to Night mode should be managed A VY Press OK to confirm Select Associated EP List Switchboard Press OK to confirm Press OK repeatedly to move the cursor to the desired EP Move the cursor to the SCS address line Press OK to highlight the value to change ODLOG Use the keypad to enter the value Press OK to confirm Press to exit the menu To activate the associated camera to select the directory or the language Select the desired item Press OK repeatedly to make the selection Press to exit the menu Q lt gt Directory type Alphanumeric for each contact
11. oes not indicate wrong and or faulty operations 27 BTicino SpA Via Messina 38 20154 Milano Italy www bticino com BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to the same
12. quired 4 Replace the cover btiicine 4 Settings After connecting and powering the switchboard press OK to display the main menu Use the keys A V to select the desired functions and press OK to confirm For a detailed description of all functions refer to the user manual that can be found in the CD supplied Use the configuration icon to access to the installation setup menu This menu is password pro tected and can only be accessed by the installer WARNING Wrong actions may compromise the operation of the switchboard A 4 gt Select the Configuration functions Press OK to confirm Conio uran Orn lt gt Select the Installation Setup function Press OK to display the access screen 10 Switchboard Enter the password using the keypad default password 12345 Press OK to confirm The following icon screen appears Handset IU D N function Slave handset IU Modify contact Time bands Automations Function key setup Alarm setup Configuration O ON A UU FF W NY Change password 11 btiicine 4 Settings 4 1 Handset IU D N function This can be used to enable or disable the handset Day Night function A 4 gt Select the handset D N function VW Press OK to access the menu OK Press OK repeatedly to enable disable the D N function 5 Press to exit the menu 12 Switchboard 4 2 Slave handset IU It can be used to enable or disable the slave
13. to associate with the key Press to exit the menu db List of configurable functions Door lock 1 to 5 Handset Day Night Entrance panel Day Night Presence status Slave handset Staircase light Handset Call Entrance panel Call Switchboard call not configured 19 4 Settings 4 7 Alarm setup It can be used to enable or disable alarms burglar alarms panic alarms technical alarms the contact for the external siren or luminous signalling accessible from the back of the switchboard 4 gt Select the Alarm Setup function Press OK to access the menu e leg Sey Ge Wao v gt gt Al al le mS lt gt Select the desired item A Enabled Press OK repeatedly to enable disable the function Press to exit the menu lt NOTE The alarm function can also be enabled during the day only Z N WARNING Alarms can only be managed from the main switchboard local address 0 20 Switchboard 4 8 Configuration This function enables the initial configuration through local switchboard address setup associated entrance panel address setup associated camera enabling disabling directory type selection type 1 alohanumeric type 2 coding BPI selection of the navigation language gt Select the Configuration functions YVJ Press to access the menu To change the local address of the main EP A V Press OK to confir
Download Pdf Manuals
Related Search
Related Contents
ASTRAL ICE GENERATOR Catalogo IAPIR ANTINCENDIO American Standard 670.312 User's Manual URINE - Atalmedial CAChe User Guide Denon AH-C400 User's Manual Copyright © All rights reserved.
Failed to retrieve file