IPE-50 User Guide Section 1

image

Contents

1. 18 DESCRIPTION OF THE STEPS TYPE Ind Ch Standard using for 1 to 4 independant channels selection of the channel displayed by the key MODE and key gt T lt and validation with key 1 DEP Ch Using for the connection of 2 to 4 identical sensors on a same system TrAnSM same as for ind Ch except that the keys the zero tracking and the autozero at the startup are disabled and it is possible with one serial command to receive the values of all the activated channels F ModE FunCt FUNCTIONING MODE Std Kg Ib conversion ntGS Net weight gross weight conversion inout Input output weigh MAStr Master to use with 1 to 4 slaves IPE50 ALibi Not available UISS Sensitivity times ten hLd Hold PEAK Peak detector toto Horizontal totalizer tot S Vertical totalizer Coun Counting NOTE If one has selected the inout tot o tot S or Coun mode one will be asked to also select a functioning parameter see the functioning mode section for the relative description Once the functioning mode has been selected one is asked to enable the standard printouts of that mode the display shows the message dEF Pr press to enable the printouts or C to enable just the functioning mode and not the relative printouts Std Scr SAv SCREEN SAVER If the indicator has the date time option it is possible to enable the S creen Saver function after programmable time from 1 to 255 minutes that the scal
2. Std ntGS inout gt G t 18t 2nd in out p p I MAStr nuMSL 01 04 p gt Alibi FunCt UISS hLd gt PEAk gt totMod norM t FASt t Auto tot o MAx tot T totMod gt norM t FASt t Auto gt tot S Max tot REPE gt uM APW 5 g kg t Ib Coun Wait t To setthe operating mode carry outthe following procedures Turn on the unit after 06 XX are displayed press the gt T lt the display shows menu Press gt 0 lt the display shows F MoDE press the display shows FunCt Press 1to enter the parameter With the gt 0 lt or gt T lt keys select the possible options Std ntGS inout MAStr ALibi rEPE UiSS hLd PEAK kg Ib conversion net weight gross weight conversion Input output weighing please refer to user manual 2 2 Master for using with 1 to 4 another IPE50 in slave please refer to user manual 2 2 memory Alibi DSD option please refer to user manual 2 2 repeater mode please refer to user manual 2 2 Sensitivity x10 Hold please refer to user manual 2 2 Peak detector please refer to user manual 2 2 11 tot o Horizontal totalizer please refer to user manual 2 2 tot S Vertical totalizer please refe
3. LED FONCTIONS Indicates that the weight detected on the weighing system is near zero os within the interval of 1 4 to 1 4 of the division Indicates that the weight is unstable NET Indicates that the displayed weight is a net weight SPE Indique que l IPE5OP est dans un mode de fonctionnement particulier W1 SP1 ou W1 or W2 show the functionning with 2 weighing ranges 2 5 2 SP1 or SP2 Indicates that the relay 1 or 2 has been enabled SCALE KEY FUNCTION Zeros the displayed gross weight if is within 2 to 50 of the total Capacity 2 max intrade mode Cancels the negative tare value 0 0 0 If pressed for an instant it carries out the semiautomatic tare If pressed at length it allows entering the manual tare from keyboard Cancels the negative tare value In the numeric input phase it increases the digit to be modified Itcarries out a specific function of the operating mode set in the set up environment In the numeric input phase it selects the digit to be modified from left to right It carries out a specific function of the operating mode set in the set up environment In the numeric input phase it confirms the entry made In the SET UP itallows to enter a step orto confirm a parameter within a step It transmits the data from the serial port dedicated to the printer Itturns the instrument the mode stand by I
4. and then 000000 Enter the desired value using the following keys gt 0 lt decreases the blinking digit T lt increases the blinking digit MODE selects the digit to be modified blinking the scrolling of the digits takes place from left to right if pressed for an instant it quickly zeros the present value if pressed at length it allows to return to weighing without saving the changes made NOTE With the IPE50P one enters the value directly with the numeric keyboard Confirm with the 1 key the value will be subtracted from the weight present on the plate and the relative pilot lights will turn on If the entered value is not a multiple of the scale s minimum division it will be rounded up if it is equal or greater than half of the division or rounded down if lower In any case a new tare operation cancels and substitutes the preceding one CANCELLING A TARE One can manually cancel the tare value in different ways unload the scale and press gt 0 lt ou T key carry out the tares in deduction partially unloading the scale and pressing gt T lt to zero the display press C without unloading the scale enter a manual tare equal to 0 NOTE it is possible to automatically cancel the tare value see the section LOCKED UNLOCKED DISABLED TARE SELECTION SELECTION OF LOCKED UNLOCKED DISABLED TARE Normally when a tare value is entered automatic manual or from storage by unloading th
5. 7 15 WEIGHING INDICATOR REPEATER SERIE IPE 50 User manual 1 2 For calibration and basic function See user manual 2 2 for special functionning mode and output RS 232 485 this manual is available on our Web site www scaime com SUPPORT gt product documentation gt product user manuals NU IPE50 2 E valid from version 06 01 SCAIME SAS BP501 74105 ANNEMASSE France T l 3345087 78 64 Fax 33 4 50 87 78 46 www scaime com 8 9 INDEX INTRODUCTION MAIN TECHNICAL SPECIFICATIONS DIMENSIONS POWER SUPPLY amp START UP FRONT PANEL KEYS AND INDICATORS BASIC FUNCTIONS SELECTABLE OPERATING MODES 7 5 Setpoint adjustment INSTRUMENT MESSAGES WHILE IN USE INSTALLATION 10 BLOCK DIAGRAM 11 SETUP 12 ADJUSTMENT 13 ANALOG OUTPUT 14 ERROR MESSAGES P3 P4 P5 P8 P8 P10 P10 11 15 16 17 20 26 P31 P32 1 INTRODUCTION The purpose of this manual is to help the user get to know the weight indicator s various functioning modes the keys functions and the display indications We advise to carefully follow the instructions for programming the weight indicator by taking actions not indicated this manual one could cause the scale to not work properly In addition to having all the characteristics of a high precision scale the indicator has the kg lb conversion function the gross weight net weight conversion set poi
6. QI gt se PES O eE FLO fsc OJ 2 Ox i8 C N r 2 four i 2 5 Q COM D oun LS P GND O jours 1 _ FH fee 8 MULTICHANNEL L los Ny BUS land2 Connection of power supply 12 to 24Vdc 3 connection of the 2 inputs the contact of setpoints and RS232 and 485 4 connection of sensors 5 connection of the 2 to 6 contact relays 6 relays in option IPE 50 DIN c 20 JO aala ma A LIN e koa 2 Rd No EIR PS NL UN A wo i L J J Y OOOO OOOO OOOO OOOO ZZ 48 land2 Connection of power supply 12 to 24Vdc 3 connection of the 2 inputs the contact of setpoints and RS232 and 485 4 connection of 1 to 4 sensors 1049F1 Dis IPE50 XLR mGa Ve 1 gland for power supply connection 110 220Vac 2 gland for sensor connection 4 POWER SUPPLY amp START UP Do not connect other equipment to the same socket as the one that the adapter is in Do not step on or crush the power supply cable Power supply for IPE50 is from 12 to 25Vcc except IPE50XLR The display shows in sequence 6 01 indicate the version of software if you press the key gt 0 lt 09 01 09 indicate the type of unit 01 indi
7. points 1 21 Once the calibration has been made of all the necessary points press the C key various times until the indicator shows SAVE in the display confirm with to memorize and return to weighing N B the calibration points must be increasing point 1 point 2 point 3 22 Theorical calibration Press the key gt 0 lt twice thEo CA is displayed press Attention this type of calibration is less accuracy than with real load on the system 23 CEL SEn signal in mV V of one or many loadcells connected press 1 Enter the signal value of one or many loadcells corresponding at the value which will be setting in the step CEL CAP attention if many loadcell are connected to the IPE50 1 loadcell of 10t with signal of 2mV V you enter 2mV V for 10t in step CEL CAP Ex 3loadcells of 10t with signal of 2mV V you enter 2mV V for 3x10t 30t in step CEL CAP Press 1 24 CEL CAP range of one or many loadcells connected press 1 Enter the range of one or many loadcells corresponding to the value entered in step CEL Sen attention if many loadcell are connected to the IPE50 1 loadcell of 10t with signal of 2mV V you enter 10t for 2mV V in step CEL SEn 3loadcells of 10t with signal of 2mV V you enter 3 10 30t for 2mV V in step CEL SEn Press J 25 DEAd d dead load If you want to enter the value of the system dead load empty silo weight for ex press 1 in other case press gt 0 lt kno WGtis dis
8. 100 0 seconds of delay that the relays could not be on even the display is upper than the setpoint value after this delay le relay could be on if the display is upper than the setpoint value The value 0 0 disable this function 0 0 The same configurations are valid for rEL b 2 RELAY 2 An out ANALOG OUTPUT MODE Ao no the analog outpout is disable Ao nEtthe analog outpout is enable and on the net value of the display Ao Gro the analog outpout is enable and on the gross value of the display Ao MAH Adjustment of the maximum signal ex 10V 20mA Ao Zer Adjustement of the signal for the display is equal at 0 Ao Min Adjustement of the minimum signal ex OV 4mA SiGn PoSit the output will function only on the positif display nEGAt the output will function only on the negatif display Nota adjustement of the analog outpout chapiter 13 dEFAu INITIALIZATION OF THE UNIT Through this step one can initialize the instrument with the subsequent activation of the default parameters By pressing 1 a confirmation message dF Lt will appear confirm again with J or exit with any other key NOTE The initialization of the instrument causes a cancellation of the present calibration and the activation of the default parameters In any case if one exits the setup environment WITHOUT CONFIRMING the modification made all the parameters of the last saving made will remain including the calibration Inl AL INITIALIZATION ALIBI DSD MEMO
9. environment of the scale when turned on press for an instant the TARE key 2 Enter in the SEtuP ConFiG O CALib step and press key the display shows CAL 0 3 Putthe tare on the scale and press key to confirm the operation 4 Once the zero calibration is made press many times the C key until the indicator shows SAVE in the display confirm with to store and return to weighing 30 13 ANALOG OUTPUT This IPE50 has an analog output 0 10V or and 4 20mA which is automatically calibrated for the higher value 10V or 20mA of the max capacity selected in rAnGE 1 These outputs correspond to the displayed value You must adjust this output through the step and AoZEr see step after It works only on a positive display if the step SiGn PoSit if the display is negative the output will be the minimum value set at Ao ZEr step It works only on a negative display if the step SiGn 2 nEGAt if the display is positive the output will be the minimum value set Ao ZEr step It is possible to modify these adjustments in the step An out Aono gt Gro AonEt gt AoMAX 6 5 XXXxxx SEtuP ConFIG ModE gt AoZEr p AoMin P PoSit nEGAt MODE Ao the analog outpoutis disable Ao nEt the analog outpout is enable on the net value of the display Ao
10. lt or gt T lt key to enable this other relay of the connected expansion boards 24 Press C to exit this step InPutS TEST OF THE 1 0 EXPANSION BOARD INPUTS By pressing the instrument displays i bx y in which x y indicate X the input which is controlling 1 2 to change the input which one wants to control press the ZERO or TARE keys y the input status 0 Disabled input 1 Enabled input communication error with 1 0 expansion board or board not present Press C to exitthis step Anout ANALOG OUTPUT TEST You could simulate a value of the analog output by modification of the value This value can be modify between 0 to 65535 valid by 1to simulate the output Press C to exit this step Appoximative values Valeur du convertisseur A D sortie V sortie mA 1200 0 0 12700 4 58600 20 62650 10 25 12 ADJ USTMENT Nota if the IPE50 has never been calibrated the message Err 39 will be displayed press the key gt T lt to into the menus Depending on the application one can carry out two types of calibration the one for the simple scale or the one for the pallet truck SETUP ENVIRONMENT 1 2 gt 0 lt Decreases the selected digit blinking T lt Increases the selected digit blinking MODE Selects the digit to be modified blinking from left to right C Quickly zeros the displaved value Valid the new value by pr
11. sensitivity ten times greater in fact one will note that the last digit on the right of the display will have a sensitivity equal to the scale s division divided by 10 If a printout is carried out the weight values are printed with the normal sensitivity 7 4 SETPOINTS static relays The IPE50 unit is available with 2 setpoints 6 setpoints in option with IPE50 Panel In the menu output you must select for each relay the mode of functioning the status of the contact with or whithout hysteresis euet FunC Functionning mode of the 2 setpoints available for setpoint 1 to 6 12 OnonE the setpoint is disable 1GroS setpointon the gross display 2nEt setpoint on the net display 3PCS setpoint on the counting mode 4 Gro O the setpoint will be actionned when the display will be at 0 in gross value 5 nEt O the setpoint will be actionned when the display will be at 0 in net value 6 Moti the setpoint will be actionned if the display is not stable LED on 23 K Pr or 24 K oK When you press the key 1 the contact will be closed during approximatively 2 seconds 25 K Mod When you press the key MODE the contact will be closed during approximatively 2 seconds 26 When you press the key C the contact will be closed during approximatively 2 seconds 27 K Zer When you press the key gt 0 lt the contact will be closed during appro
12. the setpoint will be actionned when the display will be at 0 in net value 6 Moti the setpoint will be actionned if the display is not stable LED on 23 K Pr or 24 K oK When you press the key 1 the contact will be closed during approximatively 2 seconds 25 K Mod When you press the key MODE the contact will be closed during approximatively 2 seconds 22 26 When you press the key C the contact will be closed during approximatively 2 seconds 27 K Zer When you press the key gt 0 lt the contact will be closed during approximatively 2 seconds 28 K tAr When you press the key gt T lt the contact will be closed during approximatively 2 seconds 29 Err the setpoint will be on if the display shows the message overload or underload rEL 1 to rEL 6 selection of setpoint 1 or 6 for programmation of the parameters 6 relays in option for 50 Panel only no nC no normaly openned or nC normaly closed onStAt drCt the relay could change if the display is unstable or StbL the relay could not change if the display is unstable LED off rL iSt selection without iSt oFF or with iSt on hysteresis EnAb tM Select a time from 0 0 to 100 0 seconds that the relays will be on if the display is upper than the setpoint value after this time the relay will switch off even the display is upper than the setpoint value The value 0 0 disable this function 0 0 DELAY Selecta time from 0 0 to
13. with the key Nota the position of the decimal point will be set later step dECI 7 Select the AnGE2 if the system is a simple range SET this value to 0 and press i Set the capacity of the second range and press 8 Select the diU step and press 1 Set the minimum division and press selectable values 1 2 5 10 20 50 1 9 Select the dECI step decimal point and press i The selectable values are 1 0 a decimal 1 00 two decimals 1 000 three decimals 100000 no decimal confirm with 1 0 10 Select the u M step and press i Set the unit of measure g Lb t kg and press i kg 11 Select the CALib P calibration steps and press i 12 Select the ntP step and press i With the gt 0 lt or gt T lt keys set the number of points with which wants to calibrate from 1 to 3 with 1 it does the zero point and one weight point and press 1 13 Select the tP 0 scale zero point step and recording of the signal of the loadcell unload the scale position 0 and wait a few seconds then press the unit will go automaticly to the next step after recording the sensor signal 14 Select the ddt1 setting first reference weight step press 1 enter the weight value that you are applying on the loadcell and confirm with i 15 Select the tP 1 acquisition of first reference weight step put the weight equal at the value on on the loadcel
14. 1 channel are actived if you press the key gt T lt ot gt 0 lt you could select one of the channel Ch1 to 4 in the mode dEP Ch itis also possible to see the SuM of the channels If this number is higher than the display can show the message h 1 to 5 is shown and after the value of converter points Press C to exit this step diSPLA DISPLAY TEST By pressing the instrument turns on all the display segments at a time after which it exits automatically from the step KEYb KEYBOARD TEST By pressing the instrument displays 0000 by pressing the keys one at a time the relative codes are rebrought to the display One exits pressing the same key three times SEr SERIALS TEST By pressing the instrument displays 5 xy in which x indicates the status of the printer serial port while y indicates the status of the PC serial port Both can take on two values 0 Serial port does not work 1 Serial port works During the test one should shortcircuit T with R in the PC terminal board TXD with RXD in the PRN Works only in RS232 Furthermore the ASCII TEST CRLF gt string is continuously transmitted on both the serial lines CtS St TEST OF THE CTS STATUS By pressing one views the status level of the CTS signal of the printer on connected to the PRT serial port outPut TEST OF THE 1 0 EXPANSION BOARD RELAYS By pressing the instrument displays rEL 1 and enables relay 1 of the expansion board press the gt 0
15. Gro the analog outpout is enable on the gross value of the display Ao MAH Adjustment of the maximum signal press key You can adjust the maximum value of the signal for the maximum display The value must be set between 0 and 65535 see chart below You can modify the value with the arrow keys and confirm with key Ao ZEr Adjustement of the signal for the display is equal at 0 You can adjust the minimum value of the signal for the 0 display The value must be set between 0 and 65535 see chart below You can modify the value with the arrow keys and confirm with key Ao Min Adjustement of the minimum signal ex OV 4mA You can adjust the minimum value of the signal The value must be set between 0 and 65535 see chart below You can modify the value with the arrow keys and confirm with key SiGn only if Ao nEtis selected PoSit the output will function only on the positif display nEGAt the output will function only on the negatif display APPROXIMATE VALUES BETWEEN THE D A CONVERTER AND ANALOG OUTPUT D A CONVERTER VALUES VOLTAGE VALUE V CURRENT VALUE mA 1200 0 0 12700 4 58600 20 62650 10 31 14 ERROR MESSAGES While using the indicator itis possible to incur in the following errors MESSAGE DESCRIPTION PREC It is displayed if one tries to calibrate a point without first having confirmed the number of calibration point
16. RY option Initialization and reset the alibilDS D memory if installed DiAG DIAGNOSICS MENU 5 a Submenu inside which it is possible to check the software components and the scale hardware PrG Uer CHECKING THE SOFTWARE VERSION 23 By pressing the instrument shows the software version in the XX YY ZZ format diV int CALIBRATION INTERNAL DIVISIONS OF CALIBRATION By pressing the instrument shows the calibration internal divisions when the unit has been ajusted Press to exit this step AdC uU MICROVOLTS By pressing the instrument shows the output signal of the loadcell in microvolts relative to the weight on the sensor If more than 1 channel are actived if you press the key gt T lt or gt 0 lt you could select one of the channel Ch1 to 4 in the mode dEP Ch itis also possible to see the SuM of the channels Note The maximum voltage that the instrument accepts in input is 30 mV 30000 uV the weighing system is powered by the indicator at 5 VDC A correct operation will have a value less than 30000 with a weight of full scale capacity on the weighing System Press C key to exit this step AdC MVV sensitivity By pressing the instrument shows the signal of the loadcells in mV V corresponding at the weight on the system ex 1 00895 Press C key to exit this step AdC Pnt CONVERTER POINTS By pressing the instrument shows the A D converter points relative to the weight on the scale If more than
17. ay is higher than the max capacity programmed in calibration mode Message displayed when the display is lower than the zero memorized in calibration mode In Alibi mode when you switch on the unit the unit detects a problem with the alibi card AL Err check that there is a alibi card inside the unit Print under way PRN serial port is occupied or indicator waiting to transmit a printing to a BuSy UnStAB One is trying to print with an unstable weight One is trying to print with the weight in underload or in overload in other words with a weight un oVEr of 9 divisions greater than the capacity or of 20 divisions below the gross zero GroS Er One is trying to print with a not positive gross weight equal or less than zero NetErr One is trying to print with a not positive net weight equal or less than zero LoW Net weight less than the minimum weight provided for the printing or the totalisation no 0 uns Weight not passed by net 0 or by instability In standard mode with approved instrument one is trying to print while the instrument is ConV converting the unit of measure In the input output mode set as in out one is trying to acquire a second time the input no in weight In the input output mode set as in out one is trying to acquire a second time the output no out weight In the input output mode set as G t or 1st 2nd one is trying to acquire a second time the no 1 input weight In the input
18. cate the metrological software version XX YY ZZ version of the installed software DGTX name of software Ex 15001 the max capacity and the round CloCK if the option timer is installed After this the programmed capacity and minimum division are displayed then the instrument executes a countdown self check and finally hi rES is displayed in case of non approved instrument or LEGAL and the calibration area in case of approved instrument The indicator has an auto zero at start up function in other words it means that with a non approved instrument the display shows the present weight after a few instants while with an approved instrument Zero is shown continuously on the display until the weight does not re enter within this tolerance the auto zero function at start up may be disabled in the set up environment only with non approved instrument see SEtuP ConFiG Param Auto 0 TECH MAN REF TO stand by the IPE50 keep the C key pressed until the OFF message appears on the display then release the key the power supply of the sensors 5V is always present Press the C key to restart the unit To TURN OFF the IPE50 switch off the power supply 5 IPE50 FRONT PANEL KEYS AND INDICATORS The front panel of the indicator is designed for quick but simple weighing applications It consists of an LED display with 6 digits 13 mm in height 6 LED indicators and a keyboard 5 function keys IPE50 P
19. e is unloaded the time is shown on the display in the HH MM SS format As soon as a weight variation is detected or a key is pressed the indicator displays the current weight once again no Disabled yES Enabled one is asked to enter the time which the indicator waits to activate the screen saver after the weight has become stable and keys are not pressed no irConF remote control configuration IPE50 XLR only ir no remote control disable irl all the remote control keys work as the TARE key ir 4 the remote contrl keys work as ZERO TARE MODE and ENTER PRINT ir no rEACt REENABLING OF THE PRINTOUTS AND THE INDICATOR FUNCTIONS While using the indicator it is possible to incur in the no 0 unS error shown on the display accompanied by an acoustic signal this means that the printout or the function which one wants to carry out must be renabled in order to avoid accidental executions 19 It is possible to set the reenabling in the following modes passage of the net weight by zero weigh instability or always ZEro passage of the net weight by zero inSt instability ALWAyS always Zero L int DISPLAY INTENSITY IPE50 XLR only Lint 1 minimum to Lint 4 maximum Lintl CLoCK DATE TIME ADJ USTMENT OPTIONAL In this step one sets the date and time of the indicator by pressing J one is asked to enter in this order the day month year hour and minute The entry
20. e scale plate the display shows the tare value with a negative sign LOCKED TARE For one s convenience it is also possible to choose that the tare value cancels itself automatically each time that the scale is unloaded UNLOCKED TARE or disable the tare functions With the UNLOCKED tare 10 In case of SEMIAUTOMATIC TARE the net weight before unloading the scale may also be 0 In case of MANUAL TARE or FROM DATABASE the net weight before unloading the scale must be of at least 2 stable divisions To set the type of tare Select menu F Mode Press 110 enter the menu Press gt 0 lt many times to scroll ahead through the parameters or gt T lt to scroll backwards until one finds the t parameter Press 1to enter the parameter With the gt 0 lt or gt T lt keys select the possible options LoCK locked tare unLoCK unlocked tare diSAb disabled tare Confirm with 1 Press the C key many times until the display shows the message SAVE Press 41 confirm the changes made or another key for not saving 7 SELECTABLE OPERATING MODES In addition to the STANDARD weighing mode with TARE deduction and transmission of data the indicator can carry out one of the following functions kg lb CONVERSION NET GROSS SWITCH SET POINT ON THE GROSS WEIGHT SET POINT ON THE NET WEIGHT IN OUT ALIBI DISPLAY WITH SENSITIVITY X 10 HOLD THE DISPLAY PEAK HORIZONTAL TOTALIZER VERTICAL TOTALIZER and PIECE COUNTING
21. ery slow for high resolution 20 dYn 0 to 3 filter for crane scale FF 400 can be used only in transmission mode via RS port Custom reserved for factory don t used it The higher the filter value is and greater is it intervention relative to the type of filter used FLt 3 Nota the filter FF 200 is not suitabable in the mode DEP Ch for 3 or 4 channels Auto 0 AUTOZERO AT THE START UP By pressing one chooses whether to enable EnAb or disable diSAb the automatic acquisition of the gross zero upon start up By choosing EnAb if upon start up a detected weight is within XX of the capacity value set in rAnGE 1 it is zeroed if the weight is not within this tolerance the non approved instrument s display will show the present weight after a few instants while an approved instrument will continuously show ZErO on the display until a weight within tolerance is placed If you choose EnAb the step C PerC will be displayed press you can choose a number from 1 to 50 1 to 10 in trade approval mode value in percentage of the capacity EnAb 50 2 in trade approval mode 0 PErC key gt 0 lt You can change the percentage of the function of the hey gt 0 lt from 0 the key is disable and 50 in trade approval mode 2 max This value is a percentage of the max capacit set in ConFiG CALIB gt RAnGE1 Ex RAnGE1 500 0 and 0 PerC set at 20 gt 20 of 500 0 100 0 if the weight is higher than 100 0
22. essing the key Enter the SET UP environment of the scale when turned on press the gt T lt key for an instant during the countdown TypE is displayed Press i ind Ch or DEP Ch or trAnSm is displayed With the key gt 0 lt choose the functioning mode and press 4 Ind Ch Standard using for 1 to 4 indepand channels DEP Ch Using for the connection of 2 to 4 identical sensors on a same system TrAnSM idem that ind Ch exept that the keys the zero tracking and the autozero at the startup are disable and it is possible with one serial command to receive the values of all the channels operating 26 TranSm idem that ind Ch exept that the keys the zero tracking and the autozero at the startup are disable and itis possible with one serial command to receive the values of all the channels operating ind Ch for DEP Ch see paragraph after 3 Select the SEtuP with key gt T lt then 1 ConFiG with key CALib with key gt T lt and press 1 4 NChAn is displayed press gt Ch x where x is the channel number which must be adjusted for 1 channel or 1 sensor choose Ch 1 because the sensor must be connected in channel 1 CELL1 5 ParAM is shown choose CALib with key gt 0 lt and press 1 6 Select the rAnGE1 step and press i Set the total capacity of the scale or the first range in case of multirange functioning ex 002 000 it means maximal display of 2 000 Confirm
23. gross weight is lower than it it disables the concerned relay and an ENABLING one which when the gross weight is equal or greater than it it enables the concerned relay By keeping the key pressed for about 3 seconds one enters the DISABLING and ENABLING SET POINT values only for the configured relays The display shows S1 enable relay 1 SET POINT press to enter the Step Use the MODE key to choose the digit to be increased BLINKING DIGIT the scrolling of the digits goes from left to right Decrease or increase the value using the gt 0 lt or gt T lt keys When finished entering the values confirm with 1 The display shows S1 oFF desable relay 1 SET POINT enter the weight value like in the preceding SET POINT and confirm with with the C key one quickly zeros the set point value Inthe same way go ahead with the Sb2 on Sb2 0FF Once finished the programming of the set points one should exit with the C key to return to weighing NOTES The 0 value is valid for the enabling and the disabling set points and just the setpoints greater or equal to zero are accepted The setpoint value is entered without sign or 13 If the relay functioning mode has not been configured the prolonged pressure of the key has no effect The DISABLING SET POINT must be equal or less than the ENABLING one if in the DISABLING SET POINT one enters and confirms a value greater than
24. irectly to the indicator s terminal board without laying other cables in the raceway Install RC filters on the contactor coils on the solenoid valves and on all devices producing electric disturbances If itis possible that condensation could form inside the weight transmitter it is advisable to leave the instrument powered at all times Electric protections fuses etc are provided by the technician installing the instrument Do not install anywhere where there is the risk of explosion All cables must be wound at least once around the ferrite ring before being connected to the terminal board the cable screen must be left outside of the ferrite and should be connected to the relevant ground pin 16 10 BLOCK DIAGRAM of 0 no ERN P19 Only XLR version SETUP ENVIRONMENT ee eee ee ee 20 If DSD otpion Diagnosic mode P23 Output relays P22 TARE t PRINT ON Stb c1 ZERO v LL USER amp TECH MENU s ONLY TECH MENU METROLOGICAL PARAMETER anaolog Output P31 CONDITIONED STEP DEFAULT VALUE 17 Adjustment calibration P26 Serial connection See user manual 2 2 for PC printer You can download it on our WEB SITE WWW Scaime com SUPPORT product documentation product user manuals gt NU IP E20 2 E
25. ls wait a few seconds and press the unit will go automaticly to the next step after recording the sensor signal 16 If a calibration point has been set once the weight acquistion has been made the display shows for an instant the value of the internal divisions and then the ntP step 27 If there are various calibration points repeat the operations for the ddt2 tP2 ddt3 tP3 points 1 17 Once the calibration has been made of all the necessary points press the C key various times until the indicator shows SAVE in the display confirm with 1 to memorize and return to weighing N B the calibration points must be increasing point 1 point 2 lt point 3 dEP Ch Select the SEtuP with key gt T lt then 1 ConFiG with key with key gt T lt and press 1 NChAn is displayed press Ch x where x is the channel number which must be adjusted for 1 channel or 1 sensor choose Ch 1 because the sensor must be connected in channel 1 CELL1 is shown choose CALib with key gt 0 lt and press 1 Select the AnGE1 step and press Set the total capacity of the scale or the first range in case of multirange functioning ex 002 000 it means maximal display of 2 000 Confirm with the key Nota the position of the decimal point will be set later step dECI 7 8 Select the AnGE2 if the system is a simple range SET this va
26. lue to 0 and press Set the capacity of the second range and press i Select the diU step and press 1 Set the minimum division and press selectable values 1 2 5 10 20 50 1 Select the dECI step decimal point and press The selectable values are 1 0 a decimal 1 00 two decimals 1 000 three decimals 100000 no decimal confirm with 1 0 10 Select the u M step and press i Set the unit of measure g Lb t kg and press kg Calibration with load on the system for theorical calibration with loadcell parameters less accuracy see paragraph 22 11 Select the CALib P calibration steps and press i 12 EquAL is displayed it is used to off center adjustments corners adjustment of the load receipter Go to the step 16 by pressing the key gt 0 lt many times if you don t want to do this adjustment 13 Eq0 is displayed the load receipter must be at zero without load the unit will memorize the signal of the load cells press 1 Eq blinks and after the unit will pass at the next step automaticly 14 Eq is displayed to indicate the adjustment of the loadcell which is connected to the channel 1 Apply the load on loading point 1 over loadcell 1 and press Eq1 blinks and after the unit will pass at the next step automaticly 28 15 Eq2 is displayed to indicate the adjustment of the loadcell which is connected to the channel 2 Apply the load on loading poi
27. lusive NOTE If the indicator is approved the step can not be modified 9 80655 21 CALib SCALE CALIBRATION ADJ USTMENT See paragraph ADJ USTMENT section 9 OCALib QUICK ZERO CALIBRATION ADJUSTMENT See paragraph CALIBRATION section NOTE If the indicator is approved the step is not displayed SeriAL SERIALS PRINTOUTS ETC Please refer to user manual 2 2 dSP rF norm keep this parameter 1 h2 2 5 h2 5 h2 10 h2 20 h2 norm dSALE Do notenter in this step no inPutS INPUT CONFIGURATION In this step one sets the function to link to each input inP bl INPUT 1 nonE Disabled ZEro gt 0 lt Key tArE T Key ModE MODE Key EntEr Key diS kEy DISABLING OF KEYBOARD nonE inP b2 INPUT 2 The programming of the inputs 2 is done as described for input 1 NOTE In case 2 inputs are simultaneously enabled with the same function just the input 1 is taken into consideration outPut RELAY CONFIGURATION In this step one sets the function to be linked to each relay NOTE the parameter is displayed only if the setpoint parameters has been selected rEL 1 Relay 1 FunC Functionning mode of the 2 setpoints available for setpoint 1 and 2 OnonE the setpoint is disable 1GroS setpointon the gross display 2nEt setpointon the net display 3PCS setpoint on the counting mode 4 Gro O the setpoint will be actionned when the display will be at 0 in gross value 5 nEtO
28. m 10 to 40 C 14 to 104 F DISPLAYED DIVISIONS 10000e 2X3000e for legal for trade use expandable to 800 000 for internal use with minimum signal coming from the 1 6mV V cell RESOLUTION IN CALCULATION 150 000 points with signal in input equal to 3mV V MAX INPUT 30mV 6mV V DISPLAY 6 digits 13 millimetres high STATUS INDICATIONS 6 LEDS KEYBOARD water resistant polycarbonate membrane keys with tactile and acoustic feedback TARE FUNCTION Available on entire range from keyboard or from optional remote control Subtraction function on all models LOAD CELL POWER SUPPLY 5Vdc 5 120mA max 8 cells of 350 Ohm LOAD CELL CONNECTIONS 4 or 6 wires with Remote Sense PROTECTIVE CASE IP 54 PVC case SERIAL OUTPUTS 1 RS232 and 1 RS485 uni directionnal or bi directional configurable for connection to P C PLC printer repeater THE PARTS OF THE INSTRUMENT CONTAINING DANGEROUS ELECTRICAL TENSION ARE ISOLATED AND INACCESSIBLE TO THE USER UNLESS IT HAS BEEN DAMAGED OPENED OR ALTERED 3 DIMENSIONS IPE50 PANEL 80 67 I 96 9 i O O O O C WC RI Q CO 4 Q 2 Z O Io gt Ol pee Qi 8 5 J se
29. n the numeric input phase it quickly zeros the present value In the set up environment it allows to exit a step without confirming the change made Cancel a tare 6 BASIC FUNCTIONS Nota if the IPE50 has never calibrated the message Err 39 will be displayed see page 31 Sometime it will be necessary to go to differents menus to modify some prameters To enter into these menus turn on the unit L 1 06 and after 05 01 are displayed press the gt 0 lt key when 05 01 is displayed after 09 01 DGT9 and the version of the software are displayed press gt T lt key during the countdown the display shows the first parameter TyP E 6 1 ZERO SCALE By pressing the gt 0 lt key it is possible to zero gross weight value which is within 2 of the capacity after the zeroing the display shows 0 weight and the LED gt 0 lt is turned on 6 2 TARE OPERATIONS SEMI AUTOMATIC TARE By pressing the gt T lt key any weight value present on the display is tared the display shows tArE for an instant and then 0 net weight the relative keys turn on In any case a new tare operation cancels and substitutes the previous one NOTE The semiautomatic tare will be acquire only if the weight is AT LEAST A DIVISION STABLE instability led off and VALID in other words the OVERLOAD condition should not be created ENTERING THE MANUAL TARE FROM KEYBOARD Press T for a few seconds the display shows tM
30. nt 2 over loadcell 2 and press Eq2 blinks and after the unit will pass at the next step automaticly Do the same for loadcell 3 or 4 if the channel 3 or 4 are connected to the loadcells When all the adjustments will be finished the message Eq OK will display to indicate that the adjustment are finished and OK 16 Select the step and press i With the gt 0 lt or gt T lt keys set the number of points with which wants to calibrate from 1 to 3 with 1 it does the zero point and one weight point and press 17 Select the scale zero point step and recording of the signal of the loadcell unload the scale position 0 and wait a few seconds then press the unit will go automaticly to the next step after recording the sensor signal 18 Select the 4001 setting first reference weight step press enter the weight value that you are applying on the loadcell and confirm with i 19 Select the tP 1 acquisition of first reference weight step put the weight equal at the value on on the loadcells wait a few seconds and press the unit will go automaticly to the next step after recording the sensor signal 20 If a calibration point has been set once the weight acquistion has been made the display shows for an instant the value of the internal divisions and then the ntP step If there are various calibration points repeat the operations for the ddt2 tP2 ddt3 tP3
31. nt on gross weight or net weight in out weigh repeater in r f transmission alibi memory hold function peak detector weighs totaliser and piece counter The indicator adapts to normal weighing applications in either industrial settings such as during factory production processes or that of commerce such as legal for trade applications also satisfying the frequently needed ability to transmit and print the data through its two bidirectional serial ports This manual has been made as carefully and exactly as possible in any case your suggestions are always welcome IN WARNING N Any attempt to repair or alter the unit can expose the user to the danger of electric shock and it will void our warranty This instrument is covered under warranty provided that IT HAS NOT BEEN OPENED BY THE USER for any reason If any problem with the unit or system has been experienced please notify the manufacturer or the dealer from which the instrument was acquired Do not pour liquids on the indicator Do not use solvents to clean the indicator Do not expose instrument to either direct sun light or any heat sources Always mount the indicator and platform in a vibration free setting Read carefully amp apply what described in the POWER SUPPLY amp START UP section Do not install in an environment with any risk of explosion 2 MAIN TECHNICAL SPECIFICATIONS POWER SUPPLY 12 to 24Vdc 3 6 W max 110 220Vac for IP ESOXLR OPERATING TEMPERATURE Fro
32. of each parameter must be confirmed with 1 NOTE the parameter is not displayed if there is no date time option tArE t LOCKED UNLOCKED DISABLED TARE SELECTION LoCK locked tare unLoCK unlocked tare diSAb disabled tare See the TARE OPERATIONS section for further functioning details LoCK AutoFF AUTO SWITCH OFF It is possible to enable the automatic switch off of the indicator from 1 to 255 minutes or disable it the auto switch off starts working when with unloaded scale the weight has not been moved or a key has not been pressed during the set time the display shows the blinking oFF message and an acoustic signal es emitted then the indicator turns off Di SAb auto switch off disabled EnAb auto switch off enabled one will be asked to enter the number of minutes after which the indicator must turn off enter a number from 1 to 255 di SAb SEtuP SCALE CONFIGURATION ConFiG configuration FiLt 50 cutoff band filter 50Hz You can enable yes or disable no a cut off band at 50Hz no Param PARAMETERS StAbiL FILTERING INTEGRATION By pressing key one accesses the selection of the type and degree of filter intervention for the stability of the weight indication FLt 0 to 3 filter for simple weighing FF 50 1to3 filter for dosage 50 measurements seconde FF 100 104 filter for dosage 100 measurements seconde FF 200 1 to 3 filter for dosage 200 measurements seconde h r 0 to 7 filter v
33. output mode set as G t or 1st 2nd one is trying to acquire a second time the no 2 output weight Er Mot In the counting mode the sampling has not been made because the weight is unstable E In the counting mode the sampling has not been made because one should use a higher rror reference quantity 15 9 INSTALLATION IN To obtain the best results it is recommended to install the indicator and the platform or transducer in a place with the following conditions A flat level surface on which to rest Stable and vibration free Moderate temperature and humidity 15 30 C and 40 70 No dust or strong vapours No draughts Mains power supply is restricted to 12 24Vdc Make sure the platform is level or that the loading cells are resting evenly Avoid welding with load cells installed When the load cells are used with assembling kits under storage bins or the like connect the upper and lower supporting plate with a copper wire cable and then earth all the upper plates Use waterproof sheaths and couplings in order to protect the load cell cables Use a waterproof junction box to connect the cells The extension leads of the load cells or signal amplifiers must be screened In addition they must be laid on their own in a raceway or metal pipe as far away as possible from the power supply cables Connection of the cell or amplifier cables on the electrical panel shall be independent and if possible connected d
34. played see paragraph after You could enter the weight dead load value with the keys If no number after the coma has been selected you could set value from 99999 9 to 99999 9 If Inumber after the coma has been selected you could set value from 9999 99 to 9999 99 29 If 2 numbers after the coma has been selected you could set value from 999 999 to 999 999 If 3 numbers after the coma has been selected you could set value from 99 9999 to 99 9999 Press Or 26 Kno WGt enter the value of the know weight on the system in another case press the gt 0 lt CEL Sen is displayed press key C th CAL is displayed press to memorize rAnGE1 is displayed see paragraph 23 If the system is loaded with a know weight you can set the unit with this weight with the keys The unit will memorize the loadcells signal and the weight Press I GET Wt is displayed press Enter the weight that you want that the unit displays Wait is displayed for several seconds the unit memorize the loadcells signal then Kno WGtis blinking and after the unit will go to the step CEN Sen press C th CAL is displayed press rAnGE1 is displayed 27 Press the C key various times until the indicator shows SAVE in the display Confirm with 1 to memorize and return to weighing QUICK CALIBRATION OF ZERO It is useful to calibrate just the point of ZERO when a permanent tare weight is put onto the platform for example a roller unit 1 Enterin the SET UP
35. r to user manual 2 2 Coun Counting please refer to user manual 2 2 Confirm with if one has selected the inout tot or tot S or Coun mode one will be asked to select another operating parameter refer to the specific functioning mode section for the relative description Once the functioning mode is selected one is asked to enable the standard printouts the dEF Pr message appears on the display press to enable the printouts and C to exit without making any modifications The instrument automatically goes to the following step Press many times the C key until the display shows the message SAVE Press 110 confirm the changes made or another key to not save 7 1 CONVERSION Std By pressing MODE key the value is converted from kg to Ib and vice versa NOTES with APPROVED instrument in single range the weight in pounds is displayed for 5 seconds after which the display goes to kilograms During the viewing in pounds it is not possible to print the weight when pressing the message ConV is shown and an acoustic signal is emitted 7 2 NET GROSS SWITCH ntgS If a tare is set by pressing the MODE key for about 3 second interval the gross weight is displayed NOTE While the gross weight is being viewed it is not possible to print 7 3 DISPLAY WITH SENSITIVITY X 10 UISS TO BE USED IN TESTING DURING THE CALIBRATION By pressing the MODE key one switches from the weight display with normal sensitivity to a
36. s ERMOT Weight unstable during the acquistion of a point during calibration ERPNT During the acquisition of a calibration point a null value has been read by the converter Er 11 Calibration error a too small sample weight has been used itis advisable to use a weight equal to at least half of the scale capacity Calibration error the acquired calibration point tP 1 or tP 2 or tP 3 is equal to the zero point Er 12 tP 0 The converter points are less than the instrument s internal divisions Er 37 The sensor signal is negative The load has not been applied on the step TP 1 It is displayed when the instrument has not yet been calibrated and initialized Er 39 press the gt T lt key when the instrument displays ERR 39 to enter the technical set up environment with the standard procedure it is not possible programming of all the parameters of the set up environment and the calibration During the calibration some internal negative points have been calculated C Er 36 the calibration point is less than the zero point the signal is negative check the connections During the calibration some internal points less than the minimum value have been calculated C Er 37 The calibration point is equal to the zero point capacity too high in relation to the division has been set HW Err Harware error Software not compatible with the installed hardware The hardware expansion is missing which allows the software to f
37. the key is not operating 50 2 in trade approval mode 9 OtrACk ZERO TRACKING This menu allows setting the zero tracking in other words the compensation parameter of the scale s thermal drift the set value corresponds to the number of divisions that is reset in the fixed time of 1 second tr Y half division tr 14 one fourth of a division tr 1 one division tr 2 two divisions tr no tracking disabled NOTE If the indicator is approved the step may not be modified tr 1 2 diU Stb DIVISIONS BY STABILITY In this step one enters the number of divisions by which the instrument detects the weight stability the higher the number of divisions less is the sensitivity and consequently the stability is more easily detected The possible values 1 19 NOTE with approved instrument it is possible to enter just the values 1 or 2 if one enters a higher value it will be confirmed but when returning to the step the last stored value acceptable is reproposed 1 5 GrAV GRAVITY ZONE AND ZONE OF USE Through this step one selects the gravity zone of calibration and of use of the instrument One may manually enter the gravitational acceleration value one must modify just the 5 decimal digits of the gravitational acceleration In case one enters a wrong g value the minimum decimal value is suggested 9 75001 a wrong value is any decimal number that is not between 9 75001 and 9 84999 inc
38. the ENABLING one the instrument will automatically set 0 value and wait for a correct value If in the ENABLING SET POINT one enters and confirms a value greather than the max capacity the instrument will automatically set 0 value and wait for a correct value The check of the weight remains active on the present value even during the modification of the SET POINT until the new value is confirmed At start up the relays are managed from when the software version is displayed and these take on the configuration set in the set up environment These are not managed inside the set up menu The tare operations are active RELAY STATUS ENABLED DISABLED S1 0F S1 0n GROSS WEIGHT MODE WITHOUT HYSTERESIS It is the same as the functioning mode with hysteresis except that one enters just one SETPOINT value 5 1 on and S 2 on therefore the enabling threshold coincides with the disabling threshold 7 6 INPUT CONFIGURATION for the 2 inputs remote control In this step one sets the function to link to each input on the screw terminal nonE Disabled ZEro gt 0 lt Key tArE T Key ModE MODE Key EntEr Key diS kEy DISABLING OF KEYBOARD nonE Nota If you select the parameter diS kEy the second input will be disabled and the keys of the unit too 14 8 INSTRUMENT MESSAGES WHILE IN USE MESSAGE DESCRIPTION TERES Message is displayed when the displ
39. unction 15 ELECTRICAL CONNECTION See user manual short guide NU IPE50 1 E 0609 32
40. ximatively 2 seconds 28 K tAr When you press the key gt T lt the contact will be closed during approximatively 2 seconds 29 Err the setpoint will be on if the display shows the message overload underload OUT 1 OUT 2 OUT 6 selection of setpoint 1 or 2 more than 2 depends of the IPE50P version for programmation of the parameters no nC no normaly openned or nC normaly closed onStAt drCt the relay could change if the display is unstable StbL the relay could not change if the display is stable LED off rL iSt selection without iSt oFF or with iSt on hysteresis EnAb tM Select a time from 0 0 to 100 0 seconds that the relays will be on if the display is upper than the setpoint value after this time the relay will switch off even the display is upper than the setpoint value The value 0 0 disable this function DELAY Select a time from 0 0 to 100 0 seconds of delay that the relays could not be on even the display is upper than the setpoint value after this delay le relay could be on if the display is upper than the setpoint value The value 0 0 disable this function SiGN the setpoint will be operating with only a positive value on the display PoSit or only with a negative value nEGAt The step will be showed only if the function of the setpoint is 2 nET 7 5 Adjustment the setpoint value MODE WITH HYSTERESIS One enters two SET POINTS for each relay a DISABLING one which when the