1. Raw counts At zero weight 10 Press the TARE key once to zero the scale 1000 Armstrong Drive Fairmont Minnesota 56031 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com For technical support contact us at 1 800 458 7062 or fax us at 1 800 368 2042 Page 12 of 18 CALIBRATION PROCEDURE NON SEALED Conitnued FUNCTION SCALE RESPONSE 11 Load the appropriate calibration weight XXXXXX See Table 3 for valid calibration weights used verify weight placed on platform is with acceptable span range 12 Press the TARE key to begin calibration CAL 13 The scale will exit out of calibration mode and return to normal weighing mode Scale will display weight used for calibration If calibration process does not correct any weighing issues contact the service department for technical support at 1 800 458 7062 Table 3 Calibration Weight Table FULL Full capacit Capacity Capacity LB Calibration Calibration Acceptable Weight KG Weight LB a Range cS _6 6KG NA CS_15 15KG 10 KG 20 LB 80000 120000 CS 30 30KG 60 20KG 40 LB 80000 120000 CS_60 60KG 50 KG 100 LB 100000 150000 150KG E a 300KG Grey Shaded areas indicate capacities only available for Model 3255 1 2 1 2 Capacit Weight KG Weight LB TE Range NA cs aoB 60110 Ka 20 6B 40000 60000 150KG ba a E 300KG Grey Shaded areas indicate capacities only available for
2. 3 seconds to enter setting function mode The scale will go into the following configuration mode ModE Unit diviS A OFF Cal_U Calu Count TrAd End Use CALL key to scroll Use SET key to scroll or accept Displays raw counts setting Full S e Table 2 for appropriate diviS oz j e On Jol of TM Lb On Off TM Oz e On Jol of A CS_30 CS60 CS_150 CS_300 See Table 1 for Mode settings Bold and gray Highlighted areas define factory default settings Table 1 Mode Setting Choose the appropriate mode setting for the capacity of your scale The capacity sticker is located on the disdlay Mode Capacity Capacity KG LB CS_60 60KG 150 LB CS_150 150KG 300 LB CS_300 800KG 600 LB For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 10 of 18 Table 2 Division Setting Table When seiting up the Mode selection each mode example CS_ 15 has 4 separate division setting which will give you the selection capacity and resolution for KG and LBS Choose the correct setting below for your needs Selectable Capacity and of divisions Capacity and of divisions Accuracy Mode Division Resolution KG Resolution LB Setting CS 15 15 0050 kg 15x0 005kg 3 000d 30 x 0 01 Ib 3 000 d 1d P 12 0020kg 15x 0 002kg 7 500d 30x0 005Ib 6000
3. limits for you to make sure the setting were stored correctly The scale will now exit from the set up mode and return to normal check weighing mode MTITI LA LILI 4 To set up additional check weight target setting repeat steps 1 3 5 To exit check weighing mode press the MODE key to exit and return to normal weighing mode Note If you do not enter a check weight limit within 10 seconds the scale will exit target settings and return to normal weighing mode If the upper limit is lower than the lower limit the buzzer will beep beep beep to remind the operator the setup is incorrect The device will auto clear the upper check weight and return to the last step upper check weight setup For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 7 of 18 USING STORED CHECK WEIGHING TARGET SETTINGS The Check weighing function can be used both in normal weighing mode and counting mode Under normal mode it stands for weight While in counting mode it stands for quantity To use a stored check weighing target setting 1 In normal weighing mode press the desired numeric key and then press CALL key to enter into check weighing mode The scale will briefly show upper and lower check weights for you to validate the correct key has been chosen and activate the check weighing function The following is displayed if you press the 3 key then CALL Purina Ls LI LI IE Camm 2 Load weig
4. tare value is stored SET Used to enter into set up for check point target settings In counting mode used to select sampling quantity In weighing mode press and hold the SET key for 3 seconds to enter into configuration mode Numerical keys O 9 Used to call out saved target settings and enter upper and lower limits For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 5 of 18 COUNTING PROCEDURE The C3255 check weigher includes a simple counting function The minimum sample size weight required is 1 5d of scales capacity and resolution Important note for accurate counting it is suggested to use the largest sample weight as possible 1 Make sure all weight is removed from platform 2 If tare is required press the Tare key prior to sampling to tare out the weight of a empty container 3 Press MODE key to enter into counting mode the display will show 4 There are four pre defined samples sizes available in the C3255 They are 10 pieces 25 pieces 50 pieces and 100 pieces Press SET key to scroll to the desired sampling quantity 5 Once the desired sampling size is chosen add the appropriate of pieces onto the platform or into the empty tared container NOTE If no weight is placed on the scale and you exit the counting function by pressing the MODE key the scale will display an invalid of pieces 6 With the sample wei
5. B KG oz to On or Off When selected units of measure is turned off the selection will not appear when pressing the mode key The default setting is ON for all units of measure DivS Select the displayed resolution of the scale for the selected capacity chosen The default setting is the NTEP approved capacity and resolution A OFF To help save battery life configure the scale to automatically shutoff after 120 180 240 300 seconds or turns the setting OFF if you have the unit plugged into an AC outlet at all times The default setting is ON CaL U Select the calibration weight used when calibrating your scale The default setting is Full CAL u Select the units of measure for calibration KG or LB The default setting is LB Count Shows raw counts of load cell and enters into calibration mode trAd Configure the scale for OFF Non TYPE approved or sealed or ON Select this feature when calibration the unit for weights and measures sealing With the Selection ON only A OFF is configurable through the keyboard configuration menu Press the sealing switch located under the battery compartment to enter into all other configuration modes End Exits the configuration mode and returns to normal weighing mode For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 9 of 18 CONFIGURATION MODE MENU The scale can be set as desired for the user Press SET key for
6. Model 3255 1000 Armstrong Drive Fairmont Minnesota 56031 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com For technical support contact us at 1 800 458 7062 or fax us at 1 800 368 2042 Page 13 of 18 Table 3 Calibration Weight Table Conitnued 1 4 1 4 Capacit n ht KG a ht LB y Range NA cs 30 30KG s0 ske lois 20000 30000 150KG a E a E 300KG Grey Shaded areas indicate capacities only available for Model 3255 SEALING YOUR SCALE FOR WEIGHTS AND MEASURES APPROVAL lf your scales requires sealing by your local weights and measures authorities please follow the instructions shown below to seal your scale IMPORTANT NOTE Once you have set the scale to the SEALED mode access to the configuration menu is limited to changing the A OFF settings only To enter into the configuration menu for the other features or to calibrate your scale you will be required to follow the steps shown on page X Calibration Procedure Sealed FUNCTION SCALE RESPONSE 1 Follow step 1 13 of the Calibration Procedure Non Sealed 2 Press and hold the SET key for three seconds to enter into the configuration mode Scale displays Mode 3 Press the CALL key 7 times to trad press the Set key Scale displays OFF 4 Press the CALL key once Scale displays ON 5 Press the SET key to active the sealing mode Scale displays trAd 6 Press the CALL k
7. SALTER OG Biechrell CHECK WEIGHER SCALE C3255 OPERATOR S MANUAL 1000 Armstrong Drive Fairmont Minnesota 56031 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com For technical support contact us at 1 800 458 7062 or fax us at 1 800 368 2042 INTRODUCTION The 3255 Checkweigher series scales are versatile and easy to use The large display is allows you to easily view the weight The 3255 allows you to store 10 preset checkweighing target settings provides a simple counting feature and is battery operated using 6 C cell alkaline batteries not included The 3255 Checkweigher series is NTEP approved at specific capacities and resolutions The stainless steel weighing platform and base allows you to wipe down the unit in moist applications Please note this unit is not intended to be used in wash down applications Please contact your local dealer to to see if your application meets the requirements of this scale The 3255 is equipped with a foldable display bracket which allows you to lower to display assembly when you are using the unit in portable applications GETTING STARTED 1 Remove the scale from it s packaging Included is the 120 Volt AC adapter user manual scale base and display assembly 2 To install the scale raise the display assembly up from the base adjust the display locking button into place and make sure the display head is locked into position 3 To ensure proper we
8. TERY POWER The 3255 battery life is estimated at 250 hours of continuous use To conserve battery life make sure you have configured the scale for Auto Shutdown see configuration section 1 Low battery indication will display on LCD display when battery s power is insufficient to power the scale 2 When is displayed remove old batteries and plug in the AC adapter or replace with new batteries For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 4 of 18 FUNCTION KEYS and DISPLAYED ANNUNCIATORS Stable weight enunciator vO Zero enunciator ON OFF MODE ZERO CALL GROSS NET TARE wn m O OO OOU NT OO a JG o oo A G A C amp Key Function ON OFF Switch on Switch off MODE Toggle between weight units mode lb oz kg and activate the counting mode pcs Key is also used to exit check weighing and return to normal weighing mode ZERO Press this key to return to zero Zero key will only operate if displayed weight is less than 2 of full scale capacity 2 CALL In checking weight mode used to activate a saved target settings In configuration mode used to scroll between setting B G Gross Net Used to toggle between net and gross weight A bullet on the display will light to indicate what mode you are in TARE Put a container on the scale press this key to tare the weight The
9. d NA 15 0010 kg 15x0 001kg 15 000d N A N A CS 30 30 010 kg 30 x 0 01 kg 3 000 d 60 x 0 02 Ib 3 000 d 1d P 80 005kg 30 x0 005kg 6000d 60x001lb INA 30 002 kg 30x 0 002kg 15 000d N A N A P 80 001kg 30x0 001kb 30 000d NA OT CNA Fee fe ee CS 60 60 020 kg 60 x 0 02 kg 3 000 d 150 x 0 05 Ib 3 000 d 1d 60010kg 60x0 01kg 6000d 150x002 NA 60 005 kg 60x0 005kg 12 000d N A N A N A 60 002 kg 60 x 0 002 kg 30 000d CS _150 150 050 kg 150x0 05kg 3000d 300 x 0 1 Ib 3 000 d 120 020 kg 120x0 02kg 6 000d 300 x 0 05 Ib 6 000 d 150 010 kg 150 x 0 01 kg 15 000 d N A N A N A 150 005 kg 150 x 0 005 kg 30 000 d CS_300 300 10 kg NA NA __ 300 05 kg NA NA 3 N A 00 02 kg N A J 300 01 kg NA NA Grey Shaded areas indicate capacities only available for Model 3255 Bold and shaded areas indicate NTEP approved capacities and resolutions only 1000 Armstrong Drive Fairmont Minnesota 56031 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com For technical support contact us at 1 800 458 7062 or fax us at 1 800 368 2042 Page 11 of 18 CALIBRATION PROCEDURE NON SEALED There are two methods of calibrating the scale Non sealed when the TrAd configuration is set to off and Sealed when the TrAd configuration setting is to on These instructions help you calibrate the scale when it is in the non sealed mode Periodically your scale may requir
10. e calibration to ensure proper weighing You will need a pre calibrated or accurate weight to calibrate the scale If calibration is performed with a weight other than a pre calibrated or accurate weight it will cause your scale to weigh inaccurately Scale calibration is accomplished when needed by the following instructions FUNCTION SCALE RESPONSE 1 Remove all weight from the platform and make sure the scale is in a level and stable environment 2 Press and hold the SET key for three seconds to enter into the configuration mode Scale displays Mode 3 Press the CALL key 4 times to CAL_U press the Set key The CAL U function allows you to set the capacity of the calibration weight Scale displays FULL 4 Press the CALL key to scroll through to choose 1 2 and 1 4 See Table 3 for valid calibration weights required 5 Once you have selected the calibration weight press the SET key once Scale displays CAL_U 6 Press the CALL key once Scale displays CAL_u The CAL_u configuration setting allows you to configure the scale to calibrate in pounds or kilograms 7 Press the SET key once Scale displays Ib 8 Press the CALL key to scroll through to choose Ib and kg Once you have selected the calibration weight press the SET key once Scale displays CAL_u 9 Press the CALL key once to scroll to Count Press the SET key once Scale displays XXXXXX
11. ey once Scale displays _END_ 7 Press the SET key to exit and return to normal weighing mode Once you have set the scale to the SEALED mode access to the configuration menu is limited to changing the A OFF settings only To enter into the configuration menu for the other features or to calibrate your scale you will be required to follow the steps shown on page X Calibration Procedure Sealed For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 14 of 18 SEALING YOUR SCALE FOR WEIGHTS AND MEASURES APPROVAL The C3255 requires a lead wire seal to seal the scale Place sealing mechanism here 1000 Armstrong Drive Fairmont Minnesota 56031 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com For technical support contact us at 1 800 458 7062 or fax us at 1 800 368 2042 Page 15 of 18 CALIBRATION PROCEDURE SEALED Breaking the seal to calibrate the scale will require you to re certify the scale with your local authorized weights and measures inspector Follow the steps below to calibrate your scale 1 Remove lead wire seal 2 Remove bolts 3 Remove the two Display Mounting locks 4 Remove 4 screws 5 Remove rear display enclosure For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 16 of 18 CALIBRATION PROCEDURE SEALED Continued The calibration button is located on the display mai
12. ght on the scale the display will flash for 3 5 seconds 7 Once the sample weight is stable the stable enunciator will light and the scale will show the value of the sample weight e NOTE If the displayed value of pieces does not equal the sample chosen repeat steps 1 7 and chose a higher sample size value 8 Press the MODE key to exit counting and return to normal weighing mode Your sample value will be saved and stored until you store a new sample size is stored NOTE The counting feature on the Model C3255 is NON TYPE approved For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 6 of 18 STORING CHECK WEIGHING TARGET SETTINGS The C3255 allows you to store up to 10 target settings using numbers 1 10 The keyboard is used to enter in you upper and lower check weight limits Prior to setting up your target settings use the mode key to scroll to the correct units of measure 1 In normal weighing mode press numerical key and then press SET key to enter into a check weighing setup mode The display will show as below ia isos a HD Sea 2 Using the numeric keypad enter in the desired lower check weight and press SET key The display will show as below i ak ac a os He EAL L lna 3 Using the numeric keypad enter in desired upper check weight and press SET key The check weighing setup process is finished The display will briefly flash the lower and upper
13. ht on platform 3 If loaded weight is in the setting weighing range LCD will show and the buzzer will continually beep until the item is removed from the platform 2 EFIE 3 LUU 4 If loaded weight under lower limit LCD will show to remind the operator the loaded weight is not within the setting range The low bar graph segment will change to indicate how close you are to achieving the acceptable weight BU igm meme 5 If loaded weight over upper limit LCD will show gt io remind the operator the loaded weight is not within the setting range The high bar graph segment will change to indicate how close you are to achieving the acceptable weight Pir mit ie E T To exit the check weighing mode please press 0 key and then press CALL key or press the MODE key Note Under check weighing mode press CALL key to call out the existed upper and lower check limit 1000 Armstrong Drive Fairmont Minnesota 56031 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com For technical support contact us at 1 800 458 7062 or fax us at 1 800 368 2042 Page 8 of 18 CONFIGURATION MODE DEFINTIONS Below is the definition of the configuration setting and the scale operations they affect Mode Select the capacity of the scale Mode Capacity Capacity KG LB 6KG 30 LB 300KG Shaded areas indicate C3255 capacities available Units Configure each units of measure L
14. ighing make sure the scale is level using the level bubble on the rear of the unit Once level tighten locking nuts using a 13 mm wrench 4 Always fit the Adaptor to the scale BEFORE connecting to an electrical outlet Disconnect from the electrical outlet BEFORE disconnecting the adaptor from the scale 5 If installing C batteries make sure you do not use the AC adapter AC adapter plug For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 2 of 18 SPECIFICATIONS Model C3255 Default Capacity 15 kg x 0 005kg 30 kg x 0 01 kg 60 kg x 0 02 kg 150 kg x 0 05 kg 60 Ib x 0 02 Ib 150 Ib x 0 05 Ib 300 Ib x 0 1 Ib 4 2400 oz x 80 OZ x 960 OZ x Full scale capacity range lative Humidit Calibration Weight Units Zero Widow Upon power up 10 of scale capacity Zero Key 2 of scale capacity Auto Zero Tracking 2 5d sane son 17 4 Lx 13 6 W x4 H Base with Display 17 4 L x 13 5 W x 19 75 H Approvals NTEP 1000 Armstrong Drive Fairmont Minnesota 56031 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com For technical support contact us at 1 800 458 7062 or fax us at 1 800 368 2042 Page 3 of 18 BATTERY INSTALLATION 1 Remove Battery Cover Screws 2 Insert 6 C cell Alkaline batteries into compartment and replace cover WARNING When using the C3255 as a battery operated scale do not use the AC adapter LOW BAT
15. n PDB underneath the battery compartment A sealing label covers the access hole Remove the label and press the calibration button The scale will now be in the configuration mode The display will prompt ModE You are now able to configure and calibrate the scale Review Configuration and calibration sections to procede For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 17 of 18 1 ERROR MESSAGES Low Battery If this message is displayed it indicates that the battery needs to be replaced Solution Replace the battery or plug in the AC adaptor for operations Below Zero The scale senses a weight value that is less than the allowable limit Solution Re power on the scale again If the message continues the operator should ask the maintenance men to check the scale Over Zero This message indicates that operator have too much weight on the scale when operator turned the scale on Solution Remove the excess weight from the scale platform and turn the scale off and then back on If the scale continues to display this message call for service Overload lf the weighting capacity exceeds the maximum capacity of scale the display will show the right message Solution Remove the weight from scale platform right away Power on zero count over calibration zero 1 0 Solution Turn the scale off and then back on Power on zero count u
16. nder calibration zero 10 Solution Turn the scale off and then back on ZF _ LILI I For technical support contact us at 1 800 458 7062 or jax us at 1 800 368 2042 Page 18 of 18