Home
User Manual
Contents
1. If PE gt 4mm From power SUDP y PE N LIZG TEF 2460 LED LUMINAIRE USER gt MANUAL SPARE PARTS Description Part No Glass dome 50480032 Cable gland ATEX IECEx Acc to cable dim TECHNICAL DATA Material Hot forged and machined brass Glass dome Power consumtion lt 10W Input voltage 100 254V AC 45 65Hz or 24V DC 30 depending on model Permitted supply 50 A 24VDC 30 short circuit current 1500A 100 254V AC 45 65Hz Expected lifetime To be within specified light output for gt 50 000 h Weight 4kg IP rating IP 66 IP 67 without drain plug according to IEC 60529 Cable entries 2 PCS M25 x 1 5 entries for IECEx ATEX approved cable glands according to IEC 60079 0 2007 IEC 60079 0 2009 Delivered with Tranberg cable glands Ex classification Ex e mb op is IIC T5 Gb Ex certificate no IECEx Pre 14 0009 Presafe 14ATEX4571 CE marking CE 0470 Tamb 55 C to 55 C Manufacturer Tranberg AS TRANBERG Tranberg AS PO Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com
2. Check the condition of the equipment and the contents when unpacking Any dam age done to the equipment during transportation is not the responsibility of Tranberg AS If the content is not complete file a claim to the manufacturer immediately The TEF 2460 is delivered with several mounting options A mounting bracket for flat surfaces is standard For the light output to be in accordance with any regulations listed in this document the perimeter light is to be mounted on a horizontal surface coincident with the helideck The luminaire must always be installed in an upright posi tion Any other mounting positions should not be used for permanent installation without a confirmation from Tran berg s technical department If the luminaire is mounted on a vessel or a floating installation movements such as roll and pitch which moves the luminaire out of its original up right position is not taken into account When mounting the top to the connection compartment make sure no cables or the safety wire are jammed between the two parts This will dramatically reduce the ingress pro tection and impair the mode of protection regarding haz ardous areas When mounted there shall be no noticeable gap between the top and the connection compartment If a gap is present after the screws are tightened lift the top turn it 90 to help the cables and wires connecting the two The terminals in this luminaire co
3. TEF 2460 LED PERIMETER LIGHT LUMINAIRE ZONE 1 amp 2 USER MANUAL IMPORTANT Read this instruction carefully before installing the product TRANBERG Tranberg AS P O Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com TUM 4524 REV A 01 12 2014 TEF 2460 LED LUMINAIRE USER MANUAL INTRODUCTION TOOLS REQUIRED Thank you for purchasing this product Regular tools required for installation For installation maintenance and assurance of a long life F Tools for mounting e g 10 mm wrench to fasten the of this product please follow this manual mounting bracket to the deck e 4 mm hexagon key Unbraco Allen key for mounting APPLICATIONS the top to the termination compartment and for the ex ternal bonding connection A long key gt 80mm is rec e Perimeter lights on helideck ommended for easy installation Green or red green light 24V DC only e 3mm hexagon key Unbraco Allen key to loosen the J i Zone 1 zone 2 and safe area screws for the terminal assembly if necessary e 32mm wrench to disassemble the blind plug and as CONTENT IN BOX semble the cable gland e Wrench for tightening the pressure nut on the cable The product is fully assembled and read
4. nsist of a terminal block for phase conductors and PE Two M5 PE screws are fitted to accept PE cables larger than 4mm The terminal block is of the Cage clamp type and there is no need for a tool to connect or disconnect the phase conductors Neverthe less a large screwdriver preferably flathead may be of good help Make sure to use IECEx ATEX approved cable glands IEC 60079 0 2007 IEC 60079 0 2009 approved for the spe cific cable diameter and type These data can be found in the cable gland datasheet Any damage caused by the use of an incorrect combination of cable and cable gland is not the responsibility of Tranberg AS and is not covered by warranty 141 C T The mounting bracket can be turned 90 f parts to form a coil and try again Mp ay 7 G Not following these instructions may lead to a risk of water cm j ingress into the luminaire The manufacturer assumes no 6 i responsibility when these guidelines are not followed J 7 n P S L lt K 1 ED driver y ED driver p 120 a To lamp s Alternative PE termination 140 O
5. y for installation gland s Do not use powertools when fastening globe SAFETY PRECAUTIONS MAINTENANCE INSTRUCTIONS Note that changes to the product and or installation of The luminaire should be inspected according to Company components which do not conform to the approval may routines The manufacturer suggests regular check for wa be a safety violation The manufacturer will inn no cir ter intrusion in the termination compartment Due to the sili cumstance be held responsible for such activity For your cone potting compound used in this product some silicone health and safety always use safety gear suited for the oil may condense on the inside of the glass All electronics task Be certain to follow codes regulations and or spe are sealed so this will have no technical concern cific procedures that are related to the installation When cleaning use only mild detergents Alcohol or petro leum based products may damage the gaskets APPROVALS IECEx ATEX CERTIFIED Ex e mb op is IIC T5 Gb According to EN 60079 0 2012 EN 60079 7 2007 EN 60079 18 2009 EN 60079 28 2007 IEC 60079 0 2011 IEC 60079 7 2006 IEC 60079 18 2009 IEC 60079 28 2006 CE 0470 TEF 2460 LED LUMINAIRE USER MANUAL INSTALLATION INSTRUCTIONS Only qualified personnel are allowed to perform installation and maintenance tasks to this product The equipment is ready for installation when leaving the production facilities of Tranberg AS
Download Pdf Manuals
Related Search
Related Contents
the great outdoors by Minka Lavery 8691-66 Installation Guide External Servers Security LRS 1-7 - Gestra AG SignalOn RF Switch Module User Manual Pdf Copyright © All rights reserved.
Failed to retrieve file