1. The disposal of the end product is regulated in Germany by Elektro G RoHS internationally by the EU Directive 2002 95 EG RoHS from 01 07 2006 or by any applicable national laws and regulations The end product is not regulated by the EU Directive 2002 96 EG WEEE and its amendment EU Directive 2003 108 EG et This floor lighting should not be disposed of with normal household waste Sa 22 64412 DEWERT Antriebs und Systemtechnik GmbH Weststra e 1 32278 Kirchlengern Germany Tel 49 0 5223 979 0 Fax 49 0 5223 75182 http www dewert de Info dewert de 44 PHOENIX MECANO ID No 64412
2. handset Depending on the version of your handset the floor lighting can be switched on and off using either one or two buttons A B gt 0 8 lt 0O O Figure 7 Handset models A UP button for the first motor on the double B DOWN button for the first motor on the drive double drive C Light button on the handset when avail able Indicated with the following symbol 8 Turning on and off The floor lighting can be turned on by simultaneously pressing the UP and DOWN buttons for the double drive s first motor The same two buttons can be used to turn off the floor lighting Depending on the version of the handset the UP and DOWN buttons for the double drive s first motor are located either in the upper row of buttons or as the left most pair of buttons on the hand set refer Figure 7 gt Some special handset versions have only a single button which is used for turning the lighting on and off Q For the battery drive emergency lowering option The floor lighting should only be used for short term illumination purposes The floor lighting is not designed for long term use because such use could cause the drive system batteries to discharge Additional information about operating the handset can be found in the operating instructions in cluded with your handset Q Close off the unused handset sockets using dummy plugs The protection against splashed water is compromised with open sockets I
3. x 30 screw also refer to Figure 5 The floor lighting must lie flat and level on its supporting surface It should only be fastened under the end product or to a double drive In the end product no me chanical forces should be put on the floor lighting Such forces could lead to damage such as cracks in the housing Figure 5 Mounting holes in the floor lighting dimensions in mm 64412 Floor lighting Installation 5 2 2 Mounting the floor lighting onto the end product 1 Select a suitable location for attaching the floor lighting 2 Use at least two screws per lamp when attaching the floor lighting The mounting holes are shown in Figure 5 3 Connect the floor lighting plug to the attached double drive or to the corresponding socket on the drive control unit A For versions with IP44 and IP66 protection Do not use a plug unless it has a sealing washer Both the floor lighting plug and the handset plug must have a sealing washer The washers ensure that the connections are properly protected against any splashed water 4 Connect the handset plug to the handset socket on the floor lighting if available refer to Figure 2 5 Snap on the shield cover The handset plug is securely connected to the drive once the cover is properly snapped on 6 Close off the unused handset sockets using dummy plugs 64412 15 Installation 5 2 3 16 Floor lighting Mounting the floor lighting to a doubl
4. Check the housing for breaks or cracks Check that all electrical cables and connections are firmly seated and correctly positioned Check the connecting cables for pinching or shearing Also check the strain relief and kink protec tions mechanisms in particular af ter any mechanical load This floor lighting was designed so that it would be easy to clean sult Time interval Periodic inspections can be carried out at intervals based on the risk as sessment which you con duct for your end product At least every six months At least every six months At least every six months Never clean the floor lighting in an automated washing system or with a high pressure Q cleaner Do not allow fluids to penetrate the lighting Damage to the lighting could re Do not use a cleanser that contains benzene alcohol or similar solvents Always disconnect the mains power plug before you start to clean the drive 2 Use a standard cleanser that is suited for plastics when cleaning the floor lighting or use a moist cloth Follow the usage instructions provided with the cleanser 3 Be sure that you do not damage the connecting cables during the cleaning 64412 21 Disposal Floor lighting 9 Disposal This floor lighting consists of electronic components cables and metal and plastic parts You should observe all corresponding national and regional environmental regulations when disposing of the floor lighting
5. PHOENIX MECANO Installation Instructions Floor lighting 64412 Floor lighting Foreword Foreword Revisions Version Date Changes 06 09 First edition Disclaimer and exclusion of liability DEWERT is not responsible for damage resulting from e failure to observe these instructions e changes made to this product which have not been approved by DEWERT or e the use of replacement parts which have not been approved or manufactured by DEWERT Contact addresses 44 DEWERT Antriebs und Systemtechnik GmbH PHOENIX MECANO Weststra e 1 32278 Kirchlengern Germany Tel 49 0 5223 979 0 Fax 49 0 5223 75182 http www dewert de Info dewert de Creation of a complete operating instruction manual for the entire end product These instructions are only intended to be used by the end product manufacturer They should not be given to the operator ofthe end product The factual information contained within may be used as a basis when creating the end product manual The warning and danger notices may be particularly suited for use in the end product s manual However it is not sufficient to simply follow these notices You should also carry out an internal risk assessment for your end product This can then be used as the basis for the safety notices in your manual 64412 3 Foreword Floor lighting EU Declaration of conformity In compliance with Appendix IV of the EU EMC Directive 2004 108 EG In compliance with Appendi
6. bles from coming into contact with the floor during transport 17 Notices for operation Floor lighting 6 6 1 18 Notices for operation The factual information contained within may be used when you are creating the end product man ual The installation instructions do not contain all information required for the safe operation of the end product They only describe the assembly and operation of the floor lighting and do not de scribe the completed end product A When creating the operating instructions remember that the installation instructions are intended for qualified specialists and are not for typical users of the end product General notice gt Only handsets from DEWERT should be connected to the floor lighting since they have already been verified to work together Avoiding damage from laser light Be sure that your operating instructions inform the user about the possible risks associated with la sers Do not look directly into this light and do not point the light into other people s eyes Avoiding cable damage Be sure that your operating instructions inform the user about the possible cable risks A The cables particularly the connecting cable should not be run over In order to pre vent injuries or damage to the floor lighting no mechanical strain should be placed on the cables 64412 Floor lighting Notices for operation 6 2 64412 Examples of how to use the
7. e drive for example the DUOMAT 8 If you have purchased the single body lamp for assembly on a double drive version of the floor lighting then the floor lighting should be attached directly to the double drive F F Figure 6 Mounting to a double drive for example the DUOMAT 8 A DUOMAT 8 double drive B Socket on the DUOMAT 8 double drive C Support dome on the double drive D Mounting holes on the floor lighting E Floor lighting F Threaded screw connection on support dome 1 Place the floor lighting onto the support dome of the double drive The double drive should al ready be attached to the end product 2 Use two screws for example two 3 9 x 15 mm screws to attach the floor lighting to the support dome on the double drive 3 Connect the plug on the floor lighting to the double drive 64412 Floor lighting Installation 5 2 4 64412 Electrical connection A Electrical components should be connected or disconnected only when the mains power cord is unplugged Routing electrical cables When routing the cables be sure that e the cables cannot get jammed e no mechanical load such as pulling pushing or bending will be put on the cables and e the cables cannot be damaged in any way Fasten all cables especially the connecting cables to the end product using sufficient strain relief and kink prevention methods Be sure that the design of the end product prevents the connecting ca
8. e on safety during operations Product labelling Description of lighting Technical Specifications Installation Safety notices to observe during installation Installation procedure Notices for operation General notice Examples of how to use the handset Troubleshooting Maintenance Recommended maintenance and inspection intervals Cleaning and care Disposal Table of Contents br WO O WOW WwW e gt oe oo oNN 10 11 13 13 14 18 18 19 20 21 21 21 22 General 1 1 1 1 2 Floor lighting General About these installation instructions In order to install this drive successfully and safely in the end product these installation instructions must be observed These instructions are not an operating manual for the end product These instructions will help you to minimize danger repair costs and down times They will also help you to maximize the reliability and lifespan of the end product The notices in these instructions must be followed Their observance during installation A and connection will help to minimize e the risk of accident and injury and e damage to the floor lighting or the end product These installation instructions have been written with due care and attention However unless oth erwise required by law we do not guarantee that the data images and drawings are accurate or complete nor do we accept liability for their contents gt We reserve th
9. e right to make unannounced technical changes in the course of our continual product improvement process Conventions used Notices which do not relate to safety are indicated in these instructions with a triangular symbol gt Notice symbol Explanations of warning notices DANGER indicates a hazardous situation which if not avoided will result in serious in jury or death WARNING indicates a hazardous situation which if not avoided could result in serious injury or death moderate injury NOTICE is used to address practices which are not related to personal injury but may A CAUTION indicates a hazardous situation which if not avoided could result in minor or result in damage to the product or surroundings 64412 Floor lighting Safety Notices 2 2 1 64412 Safety Notices Proper and intended usage The floor lighting is intended to be installed in an end product e to illuminate under furniture such as hospital beds e for connecting to double drives and drive control units to provide motor adjustment capabilities for movable furniture and hospital beds and e for connecting up to two handsets depending on the design A The floor lighting should only be used for the applications described above Any other application is not permitted and can lead to accidents or damage to the unit Such non approved applications will lead immediately to the expiration of all guarantee a
10. es for mounting on the end drive product C Mounting holes for mounting on the end D Handset socket product E Snap on shield cover with the IP44 IP66 F Mounting holes for mounting onto the version DUOMAT 8 double drive G Mounting component of lamp 64412 Floor lighting Technical Specifications 4 Technical Specifications Input voltage Protection classification Light source Light emitted from diodes Protection category Colours Dimensions and weight Length x width x height Version with socket Version without socket Weight Ambient conditions Ambient temperature Relative humidity Air pressure 24V DC lil LEDs LASER CLASS 1 EN 60825 1 1994 IP20 optionally IP44 IP66 Grey Black 92 mm x 65 mm x 48 mm 92 mm x 54 mm x 48 mm Approx 100 g 10 C to 40 C 30 to 75 700 hPa to 1060 hPa 64412 11 Technical Specifications Floor lighting 65 Figure 3 Dimensions of floor lighting with socket for handset in mm and cable connection 92 Figure 4 Dimensions of floor lighting for attachment to double drive in mm 12 64412 Floor lighting Installation 5 5 1 64412 Installation Safety notices to observe during installation Basic safety rules must be followed in order to ensure that the end product can be continually op erated in a safe manner These rules must be observed while using the end product and while in stall
11. ing plate example Under bed floor light Model name 62304 Article number U in 24 V Input voltage Baujahr Prod Date Calendar week year Seriennr Serial No Serial number of the floor lighting IP20 Ce A Vx XX Use in dry rooms only Protection category Mark of CE conformity Follow special disposal instructions Software version number when available Description of lighting Floor lighting 3 10 Description of lighting The floor lighting is used exclusively for illumination under furniture or hospital beds It is used to gether with a DEWERT double drive and can be mounted either directly to the double drive or un der the end product A handset can be connected if the floor lighting is equipped with a handset socket gt We reserve the right to make unannounced technical changes in the course of our continual product improvement process The floor lighting is available in the following different versions as asingle body lamp with one socket for a handset as asingle body lamp without a socket for a handset as a single body lamp with one socket for a handset for assembly on the DUOMAT 8 double drive e as adouble body lamp with a socket for a handset as adouble body lamp with two sockets for handsets or e as adouble body lamp without a socket for a handset Figure 2 Floor lighting lamp with handset socket A Cable or plug for connecting to the double B Mounting hol
12. ing the floor lighting Ensuring operational reliability during installation The safety and reliability of the end product containing DEWERT components can be ensured by using the proper construction methods described below A Make sure that the floor lighting is positioned so that it is not possible for someone to look directly into the light For versions with IP44 and IP66 protection Do not use a plug unless it has a sealing washer Both the floor lighting plug and the handset plug must have a sealing washer The washers ensure that the connections are properly protected against any splashed water An additional shield cover to protect against unplugging is also required for IP66 pro tection This shield cover can only be removed with a screwdriver Q Do not remove the dummy plugs from the unused handset sockets on the floor lighting 13 Installation Floor lighting 5 2 5 2 1 14 Installation procedure Before installing the floor lighting make sure that you are observing all ofthe safety notices found in the Safety notices to observe during installation section Installation and dismounting for the floor lighting The mains power plug on the drive should be unplugged during the installation The floor lighting can be screwed onto the end product using the mounting holes Use at least two suitable screws for example at mounting hole A a 3 9 x 15 screw at mounting point B a 3 9
13. n extreme cases such open sock ets can lead to the destruction of the floor lighting or the drive 19 Troubleshooting Floor lighting 7 Troubleshooting This chapter describes troubleshooting methods for fixing problems If you experience an error that is not listed in this table please contact your supplier A Only qualified specialists who have received electrician training should carry out trou bleshooting and repairs The floor lighting is not There is no mains supply volt Connect the mains power functioning age The power feed from the mains Check the lead in connections and has been interrupted re seat the contacts if required The LED is defective Please contact your supplier or sales agent 20 64412 Floor lighting 8 Maintenance Maintenance You should only use spare parts which have been manufactured or approved by DEWERT Only these parts will guarantee a sufficient level of safety 8 1 Recommended maintenance and inspection intervals Type of check Check the function and safety of the electrical system Periodic visual inspection for housing damage Periodic visual inspection of the plug in connections and electrical access points for damage Periodic visual inspection for cable damage 8 2 Cleaning and care Explanation A qualified electrician should carry out this inspection Refer to the Electrical connection section in the Installation chapter
14. nd war ranty claims on the part of the end product manufacturer against DEWERT Improper usage Be sure to follow the notices below concerning improper usage You should include them in your product manual in order to inform your end product users The floor lighting should not be used A e in any environment where combustible or explosive gases or vapours e g anaes thesiology may be present e in a moist environment or e outdoors The floor lighting may not be operated by e small children You should only use spare parts which have been manufactured or approved by DEWERT Only these parts will guarantee a sufficient level of safety Safety Notices Floor lighting 2 2 2 3 2 3 1 Selection and qualification of personnel This floor lighting should only be installed into the end product by someone who has completed training in electronic motor assembly or has equivalent qualifications You should only install this floor lighting when you are qualified to do so Otherwise a properly qualified person should be found for this task Notice on safety during operations Basic safety rules must be followed in order to ensure that the end product can be continually op erated in a safe manner These rules must be observed while using the end product and while in stalling the floor lighting These rules and safety measures can be categorized as follows e construction measures before
15. the installation refer to the Ensuring operational reliability during installation section in the chapter Installation e safety fundamentals during the installation of the floor lighting and during cable and wire routing refer to the Electrical connection section in the chapter Installation e basic safety rules during operation refer to the chapter Notices for operation and e the creation of a manual for the end product which contains these and other safety rules Creating a user s manual The manufacturer of the end product must create a manual for the user of that product The safety notices in the end product manual must be written based on the end product s risk assessment 64412 Floor lighting 2 4 2 4 1 64412 Product labelling Type label Safety Notices A rating plate or type label on each drive specifies the exact name and serial number of the drive It also states the technical specifications valid for that particular drive The following illustration shows where the specifications are located on the rating plate of the floor lighting gt The rating plate shown is an example the specifications for your floor lighting may differ from this illustration UB Licht Floorlight 62304 vee M C Baujahr Prod Date 46 08 Seriennr Serial No C123456 0001 X MAAA AAA a IP20 Vor Feuchtigkeit sch tzen DEWERT Indoor use only A Phoenix Mecano Company Figure 1 Rat
16. x III of the EU Low Voltage Directive 2006 95 EG The manufacturer DEWERT Antriebs und Systemtechnik GmbH Weststra e 1 32278 Kirchlengern Germany declares that the following product Floor lighting with DEWERT control unit meets the requirements of the following EU directives e Electromagnetic Compatibility Directive 2004 108 EG e Low Voltage Directive 2006 95 EG Applied standards EN 60335 1 2002 A2 2006 e EN 55014 1 2006 e EN 55014 2 1997 A1 2001 e EN 61000 3 2 2006 e EN 61000 3 3 1995 A2 2005 EN 50366 2003 A1 2006 measured distance 5cm e In accordance with EN 60601 1 1990 A2 1995 This declaration of conformity is no longer valid if constructional changes are made which signifi cantly change the control unit i e which influence the technical specifications found in the instruc tions or the intended use Kirchlengern Germany on the 21 07 2009 Andreas Hoither Managing Director R amp D and Engineering 4 64412 Floor lighting Table of Contents Foreword Revisions Disclaimer and exclusion of liability Contact addresses Creation of a complete operating instruction manual for the entire end product EU Declaration of conformity Table of Contents 1 1 1 2 2 1 2 2 2 3 2 4 5 1 5 2 6 1 6 2 8 1 8 2 64412 General About these installation instructions Conventions used Safety Notices Proper and intended usage Selection and qualification of personnel Notic