Home

Security Alarm Display Stand for Tablet PC

image

Contents

1. it s recommended not to charge the battery over 8hours and don t connect the charger all day long 5 Attention if the alarm device cannot be firmly stuck to the table by the tape pls don t continue to use it For your shop security pls contact your local distributor
2. Security Alarm Display Stand for Tablet PC I Brief Introduction The Security Alarm display Stand can be used for display of digital products such tablet PC MP4 GPS ebook etc It s made up of in bult alarm device alarm probe display rack etc It s installed on the display rack or counter The alarm probe is stuck to the display product with 3m tape The client can conveniently take off the display product from the rack and freely test and operate the display product functions If the client wants to take away the display product the alarm device will immediately give out the continuous alarm sound until the management staff reset it with remote control II Parameters Size Length 130mm Width 140mm Height 110mm Battery type 3 7v Charging voltage DC 5v Standby time two months Alarm sound 105db Charging function It can charge the digital products NOT FP WW Anti theft method infra red remote control II Functions 1 Alarm functions If the probe cable is cut or if the probe and the display product are separated the device will give out alarm immediately 2 Backup battery Once the salespoint is powered off the backup battery insie the system can continue to provide the power to the system 3 Multiple anti removal alarm Provide multiple anti removal protective functions such as whole unit anti removal tray rack anti removal etc 4 Charging function The system can provide 5V charging voltage to cha
3. rge the digital products 5 Remote control switch The alarm probe of every port of infra red remote control functions automatically examine the reset function IV Application method 1 Tear off the tape protective film of the alarm device bottom Stick it to the clean and tidy table surface 2 Tear off the tape protective film of the sensor spring square box Stick the back of the digital product onto the sensor spring square box At this time the alarm device will continuously gives out two sounds The first sound shows initialization of the alarm device The second sound shows the working status of the alarm device 3 Insert the power line into the left insertion interface of the alarm device The red light will be on which shows charging of the alarm device It 11 be automatically off when fully charged If yellow light is on the alarm device is not in working status or it is under failure status 4 Insert one end of the patch cord into the digital product and the other end into MCUSB hole of the sensor spring line square box The digital product will be charged 5 Factory password is 3 4 5 If alarm happens aim the remote control to the alarm device and continuously press 3 4 5 the alarm sound will disappear V Usage of remote control 1 Change password Take off the sensor spring line from the telephone hole of the alarm device right side Then the alarm device will give out alarm Press the password to get rid of
4. the alarm Long press the remote control setting button and you will hear the sound Input the old password If the old password is correct the alarm device will give out two long sound for two seconds Then input the 3 digital new password The alarm device will give out the long alarm for two seconds Input the new password again When the modification of password is completed the alarm will give out three sounds The new password can be used Note the password is 3 digital number The new password shall be the same when you input them twice If the input interval exceeds 15 seconds the alarm device will give out one sound to show that the time limit for password modification has been exceeded 2 Forget the password Remove the installed alarm device from the table Insert the gem clip into small round hole of reverse side of the alarm device The yellow indicator light will flash for three times The alarm device is reset to the factory status The factory status password is 3 45 VI Cautions 1 It s forbidden to remove any parts of the products to avoid affecting the product functions and lifetime 2 The normal standby time of the in built battery is two months Pls charge it in time when battery is insufficient 3 In order to ensure the normal examination of every communication port by the main device application shall begin after every probe communication cable is correctly connected 4 In order to lengthen the battery lifetime

Download Pdf Manuals

image

Related Search

Related Contents

Hammerhead  User Manual WISE-4000 Series - Login  Exhausto GSV 200-315 - Wood Stone Corporation  WS Serie - Badshop Austria  Zoom H2 Digital Recorder SD disc Recording format WAV or MP3  TV Operating Instructions  Roteador Sem Fio LTE + 802.11b g n Manual do Usuário  取扱説明書 - 東京ガス  Documentation from training and know-how transfer  3M PF24.0W9 Black Privacy Filter  

Copyright © All rights reserved.
Failed to retrieve file