Home

"user manual"

image

Contents

1. Loosen the connecting cable from the transformer to make sure that lamp is not supplied with voltage 3 Unscrew the three screws from back cover of the lamp 4 Remove the halogen cold light bulb from its socket 5 Replace the damaged halogen cold light reflector Only Sunnex cold light reflector with part no 18562 must be used NOTE Make sure the cold light reflector is clean and without fingerprints 6 Refit the back cover with the three screws NOTE The color filter must not be removed since the color temperature of the lamp depends on this A damaged color filter must be replaced immediately CAUTION Be sure the lampshade components are properly seated when screws are tightened 2 0 Assembly Instructions Sunnex HM Light Service amp Installation Manual 3 x sunnex 2 1 HM LIGHT Mobile HM1006 37W 1 Place the pole 2 in the center housing 4 2 Press down until you feel resistance Assemble the clamp plate 5 using the provided screw 7 and washer 6 Do not tighten the screw The teeth on the plate should face inwards 3 Insert each of the 5 legs into the center housing and place the 2 lockable casters on opposite sides 4 Tighten the screw 7 Secure the legs in the housing by lining up the teeth on the clamp plate 5 with the holes in the legs 2 2 HM LIGHT Wall Articulating Arm HM28002W Wall Mount 20W Plug in transformer A Remove the screws in the wall plate 1 amp 2 B Rem
2. from the date that Sunnex receives the Product Standard shipments to the Customer will be paid by Sunnex Sunnex assumes no responsibility for shipment delays by the carrier f lf Customer requires warranty service to be provided in less than ten 10 business days but not less than three 3 business days Sunnex will charge Customer an additional One Hundred Dollars 100 00 express handling charge per request for each Product 3 4 Customer Responsibilities a To validated warranty customer is required to fill out online or provided warranty card b Customer is required to follow the user manual associated with the Product for proper operation c Customer is required to perform periodic preventive maintenance as called for in the user manual associated with the Product d Any modifications or repairs made to the Product without prior written authorization from Sunnex will render this Limited Warranty null and void Instances whereby this is determined to be the case by Sunnex technical staff will be subject to an initial service charge of 75 00 25 00 evaluation charge and 50 00 minimum labor cost 3 5 Miscellaneous In the event that any provision of this Limited Warranty should be or becomes invalid and or unenforceable during the warranty period the remaining provisions shall continue in full force and effect The provisions of this Limited Warranty shall be governed by the laws of the Commonwealth of Massachusetts witho
3. 09 Guidance and manufacturer s declaration electromagnetic emissions The HM LIGHT is intended for use in the electromagnetic environment specified below The customer or the user of the HM LIGHT should assure that it is used in such an environment a sere Electromagnetic environment guidance Emissions test Camale HM LIGHT may not be interconnected with other CISPR 15 p electrical equipment Harmonic x sunnex The HM LIGHT is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes emissions IEC 61000 3 2 Not applicable Voltage fluctuations flicker emissions IEC 61000 3 3 Guidance and manufacturer s declaration electromagnetic immunity Not applicable The HM LIGHT Image Intensifier is intended for use In the electromagnetic environment specified below The customer or the user of the HM LIGHT Image Intensifier should assure that it is used in such an environment Immunity test IEC 60601 Compliance Electromagnetic environment test level level guidance Electrostatic discharge ESD IEC 61000 4 2 Electrical fast transient burst IEC 61000 4 4 Surge IEC 61000 4 5 Voltage dips short Interruptions and voltage variations on power supply Input lines IEC 61000 4 11 6 kV contact 8 kV air 2 kV for power supply lines 1 kV di
4. TED WARRANTY ARE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES IN NO EVENT SHALL SUNNEX BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL OR TORT DAMAGES OR LOSSES WHETHER TO PERSON OR PROPERTY INCLUDING DEATH ARISING OUT OF OR RESULTING FROM ANY BREACH OF WARRANTY OR ANY OTHER LEGAL THEORY OR ARISING OUT OF OR IN CONNECTION WITH THE PRODUCT OR CUSTOMER S USE OF THE PRODUCT EVEN IF SUNNEX IS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN ANY EVENT THE TOTAL LIABILITY OF SUNNEX TO YOU FOR ANY CAUSE WHATSOEVER SHALL BE LIMITED TO THE PURCHASE PRICE YOU PAID FOR THE PRODUCT THIS LIMITATION SHALL APPLY REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT LIMITATION NEGLIGENCE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE 3 3 Claims Procedure a Customer must contact Sunnex at 800 445 7869 with a request for warranty service or to report a technical issue Sunnex Technical Support will attempt to identify diagnose and resolve the reported problem via the telephone b If attempts by Sunnex to resolve a reported problem are unsuccessful Customer will then be provided with a Customer specific Returned Merchan
5. ance according to frequency of transmitter Rated maximum m output power of transmitter 150 kHz to 80 MHz 150 kHz to 80 MHz 80 MHz to 800 800 MHz to 2 5 w outside ISM bands in ISM bands MHz GHz d 3 5 P d 1 2 P d 23 P For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be determined using the equation applicable to the frequency of the transmitter where Pis the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 The ISM industrial scientific and medical bands between 150 kHz and 80 MHz are 6 765 MHz to 6 795 MHz 13 553 MHz to 13 567 MHz 26 957 MHz to 27 283 MHz and 40 66 MHz to 40 70 MHz NOTE 3 An additional factor of 10 3 is used In calculating the recommended separation distance for transmitters In the ISM frequency bands between 150 kHz and 80 MHz and In the frequency range 80 MHz to 2 5 GHz to decrease the likelihood that mobile portable communications equipment could cause interference If it is inadvertently brought into patient areas NOTE 4 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people REV 1 JULY 2008 Sunnex HM Light Service amp Installation Manual 12
6. dise Authorization number RMA The RMA number must be noted on any correspondence to Sunnex and displayed prominently on the outside Sunnex HM Light Service amp Installation Manual 7 x sunnex packaging of any Product shipped to Sunnex c Within ten 10 days of receipt of the RMA number Customer must ship the Product to Sunnex at Customer s expense insuring the Product is recommended in either its original packaging or packaging affording an equal degree of protection to Sunnex Inc 3 Huron Drive Natick MA 01760 with a statement describing the problem in reasonable specificity Proof of purchase must be included to obtain warranty service Sunnex will not be held responsible for shipping damages that occur in transit Any damage to the Product during shipping will not be covered under this Limited Warranty and shall be subject to a service charge d Subject to the limitations specified herein upon receipt Sunnex will inspect the shipped Product and at its sole discretion repair or replace the Product with the same or a like product to the extent it does not conform to this Limited Warranty In the event Sunnex at its sole discretion opts to replace the Product should said product be discontinued or no longer be offered for sale by Sunnex a like product in design and functionality will be provided to Customer e Sunnex will ship the repaired Product or a replacement to Customer within ten 10 business days after receipt
7. fferential mode 2 kV common mode lt 5 Ur gt 95 o dip In Ur for 0 5 cycle 40 Ur 60 dip in Ur 6 kV contact 8 kV air 2 kV for power supply lines 1 kV differential mode 2 kV common mode lt 5 Ur gt 95 o dip In UT for 0 5 cycle 40 Ur 60 dip in Ur Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of the HM LIGHT Image Intensifier requires continued operation during power mains Interruptions It is recommended that the Sunnex HM Light Service amp Installation Manual 9 x sunnex for 5 cycles for 5 cycles HM LIGHT Image Intensifier be powered from an uninterruptible power supply or a 70 U 70 U battery 30 dip In Ut 30 dip in Ur for 25 cycles for 25 cycles lt 5 Ur lt 5 Ur gt 95 dip In gt 95 dip in Ur Ur for 5 s for 5 s Power frequency 50 60 If Image distortion occurs It may be Hz magnetic field necessary to position the HM LIGHT IEC 6 1000 4 8 Image Intensifier further from sources of 0 3 A m power frequency magnetic fields or to install magnetic shielding The power frequency magnetic field should be measured In the intended installation location to assure
8. ns Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the HM LIGHT is used exceeds the applicable RF compliance level above the HM LIGHT should be observed to verify normal operation if abnormal performance is observed additional measures may be necessary such as re orienting or relocating the HM LIGHT Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Recommended separation distances between portable and mobile RF communications equipment and the HM LIGHT The HM LIGHT is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the HM LIGHT can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the HM LIGHT as recommended below according to the maximum output power of the communications Sunnex HM Light Service amp Installation Manual 11 x sunnex Separation dist
9. oduct other than its normal and customary manner abuse or negligence b everyday wear and tear c alteration or modification of or to any part of the Product d improper operation and maintenance or d any repairs or attempted repairs by anyone other than Sunnex This Limited Warranty does not cover any products sold AS IS or WITH ALL FAULTS This Limited Warranty excludes the replacement of bulbs for the Product TO THE FULL EXTENT PERMITTED BY APPLICABLE LAW THIS LIMITED WARRANTY REPLACES ALL OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SUNNEX DISCLAIMS ALL OTHER WARRANTIES AND CONDITIONS EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF TITLE NONINFRINGEMENT ABSENCE OF LIENS OR INCUMBRANCES MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE REGARDLESS OF WHETHER SUNNEX KNOWS OR HAS REASON TO KNOW OF CUSTOMER S PARTICULAR NEEDS IF IMPLIED WARRANTIES MAY NOT BE DISCLAIMED UNDER APPLICABLE LAW THEN ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED INDURATION TO THE LIMITED WARRANTY PERIOD SET FORTH HEREIN AND THEREAFTER ANY IMPLIED WARRANTIES ARE EXPRESSLY DISCLAIMED No employee agent dealer reseller or distributor of Sunnex is authorized to modify this Limited Warranty or to make any additional warranties REPAIR REPLACEMENT OR REFUND AS PROVIDED UNDER THIS LIMI
10. oup I Class B Only original accessories must be used with HM light The HM light is equipped with a push button ON OFF switch on the lamp head that should be used to turn the light ON and OFF EMC The lamp complies with the EMC requirements in accordance with EN 60601 1 2 Wireless transmission equipment e g mobile phones etc should not be used in the vicinity of the lamp since this can affect the function Special care should be observed during the use of strong sources of interference e g diathermy and the like so that the diathermy cables not are placed on or close to the lamp If in doubt consult your technician or the supplier Accessories other than here mentioned are not allowed to use as they may negatively affect emissions and immunity The complete light must be recycled in accordance with WEEE standard Sunnex HM Light Service amp Installation Manual 2 x sunnex 2 3 Transportation and Storage This light is packaged in card board and should be transported protected from moisture The light should be stored in a dry environment and room temperature Transportation and storage temperature 5 F 20 C to 140 F 60 C Humidity lt 95 2 4 Bulb replacement 1 Lamp front part 18018 2 Bulb support part 18291 3 Color filter part 18676 4 MR 16 bulb part 18562 5 Lamp back part 18016 6 Screws part 4475057 1 Unplug lamp from power source and wait at least one hour for lamp to cool 2
11. ove the wall plate from casing 2 C Drill 4 holes 8mm in alignment with the holes in wall plate Make sure plate is leveled NOTE Wall plate must be mounted to wall stud or structural member D Insert the anchors into the holes and attach the wall plate with the screws provided E Attach wall casing to the wall plate with provided screws F Make sure that the wall casing is securely fastened to the plate and adjust and tighten the arm as needed i G Plug the transformer into power outlet and turn on lamp gene ae with switch on back of lamp head CAUTION The arm is equipped with friction joints Do not tighten the joints excessively as this will cause uneven movement and could damage the arm Sunnex HM Light Service amp Installation Manual 4 x sunnex 1 57 40 MM 3 70 94MM r Ls Ie et D 31 LSMM HM WALL BRACKET HOLE PATTERN 2 3 HM LIGHT Wall Gooseneck Arm HM1000 37W 1 Mount the light using four screws There are four holes on the universal mount 2 Be sure transformer plug is not plugged into power source at this time 3 After universal mount is secured plug in the plug in transformer to use the light Universal Joint HM Light Wall Gooseneck Arm 2 4 HM LIGHT Ceiling HM2017 44 1 Securely fasten lamp down tube from ceiling It is recommended that 6 5 16 diameter or larger fasteners of the proper length for your individual application be used Be sure d
12. own tube is securely mounted to structural framework Down tube should be mounted plumb and square to ceiling surface Sunnex HM Light Service amp Installation Manual 5 x sunnex 2 Be sure transformer plug is not plugged into power source at this time 3 After down tube support is secured plug electrical connectors at the end of the down tube support and lamp arm together i ax te 43 j 7 a holes 30 apart HM CEILING DOWN TUBE HOLE PATTERN 2 6 Symbols CE Mark AC powered gt o o o AC powered This product must be sorted as Waste from Electrical and Electronic Equipment WEEE 3 Sunnex Limited Warranty 3 1 Limited Warranty Sunnex warrants that the Product if properly used will be free from defects in material and workmanship for a period of three 3 years from the date of shipment to Customer This Limited Warranty extends only to the original buyer If the Product is determined to be defective within the Sunnex HM Light Service amp Installation Manual 6 x sunnex warranty period Sunnex at its option will repair or replace the Product at no charge or refund the then current value of the Product 3 2 Disclaimers and Limitations This Limited Warranty shall be the sole remedy of Customer and the sole liability of Sunnex to Customer This Limited Warranty does not extend or apply to any defects failures or damage due to or resulting from a acts of God accident misuse use of the Pr
13. that It is sufficiently low NOTE U is the a c mains voltage prior to application of the test level Guidance and manufacturer s declaration electromagnetic immunity The HM LIGHT is intended for use In the electromagnetic environment specified below The customer or the user of the HM LIGHT should assure that it is used in such an environment Immunity test e ea cot ae oer Electromagnetic environment guidance Sunnex HM Light Service amp Installation Manual 10 x sunnex Portable and mobile RF communications equipment should be used no closer to any part of the HM LIGHT including cables than the recommended applicable to the frequency of the transmitter Recommended separation distance Conducted RF 3 Vrms d 1 24 P IEC 61000 4 6 150 kHz to 80 MHz daada avia d 1 24 P_80 MHz to 800 MHz IEC 61000 4 3 80 MHz to 2 5 GHz d 2 34 P_ 800 MHz to 2 5 OHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and dis the recommended separation distance In metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol we NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situatio
14. ut regard to its conflict of laws principles This Limited Warranty shall not be modified except by an agreement signed by both parties specifically referencing this Limited Warranty This Limited Warranty represents the entire agreement between Sunnex and Customer with respect to the subject matter herein and supersedes all prior or contemporaneous oral or written communications representations understandings or agreements relating to this subject For service assistance or resolution of a service problem or for Product or warranty information write to Sunnex Inc 3 Huron Drive Natick MA 01760 or visit www sunnex com 3 6 Optional Extended Limited Warranty Plan The purchase of the Optional Extended Limited Warranty extends the duration of this Limited Warranty from a period of three 3 years to a period of five 5 years from the date of shipment to Customer The Optional Limited Warranty may be purchased at the time of the original purchase of the Product or the Extended Limited Warranty to become effective and apply to the Product Customer must pay the appropriate Extended Limited Warranty fee and upon initial purchase register each Product with Sunnex within thirty 80 days from the date of shipment to Customer by Sunnex or a Sunnex authorized dealer or reseller Sunnex HM Light Service amp Installation Manual 3 Sunnex Customer Service Sunnex Inc USA 1 508 651 0009 Sunnex Equipment AB Sweden 46 565 177 00 1 508 651 00
15. x sunnex Installation Instructions Sunnex HM Exam Light Models HM1006 37W HM28002W HM1000 37W HM2017 44 1 1 Applications This HM LIGHT is intended to be used as a medical examination lamp in consulting rooms and health care centers HM Ceiling Sunnex HM Light Service amp Installation Manual l x sunnex 1 2 Cleaning and Disinfection The lamp fixture can be cleaned as needed with a damp cloth and a mild detergent For disinfection use a soft cloth with a disinfectant solution such as isopropyl alcohol NOTE Do not introduce any fluids to the inside of the lamp head as this could cause a fire hazard The glass lens can be cleaned with a damp cloth and a mild detergent and inside part of the lens can be easily cleaned with Q tips Technical Data 2 1 Manufacturer Sales office Production Facility Sunnex Inc Sunnex Inc 3 Huron Drive 3 Huron Drive Natick MA 01760 USA Natick MA 01760 USA Phone 508 651 0009 Phone 508 651 0009 Fax 508 651 0099 Fax 508 651 0099 Email sunnex sunnex com Email sunnex sunnex com 2 2 Technical Data Safety Class l o Transformer Medical Grade Plug in transformer INPUT 120VAC 60Hz 0 5A OUTPUT 12VAC 5 0A MAX Part GS 1451 INPUT 230VAC 50Hz OUTPUT 11 5VAC Part 18395 EURO 18396 UK 18397 AUSTRALIA Certifications ETL Listed CAN CSA C22 2 No 601 1 M90 EN60601 1 UL60601 1 EN60601 2 41 IEC60601 2 41 IEC 60601 1 2 2001 09 2nd edition EN55011 1991 Gr

Download Pdf Manuals

image

Related Search

Related Contents

  MANUEL D`UTlLISATIÜN MANUAL DEL    MH6-U USER`S MANUAL    取扱説明書  Opti Tri Par User Manual  GESTION ET COMMUNICATION DE CRISE ESEN sélection de  

Copyright © All rights reserved.
Failed to retrieve file