1. SERN DT Operating Instruction Manual for Instrument Panel IT 992 SEKRUIDT Art Nr 930 420 Page 1 5 Contents Description Safety Information Operating Instructions and Display Transport Storage Installation Electrical Installation Power Up Maintenance Enclosure m N 208 OT RD ID Description The instrument panel IT 992 is used to control the electrical functions of the living room area It is part of a system consisting of a EBL with charging unit complete 12V distribution and alternati vely rod tank sensors or tank sensors for filling level measurement of the water tanks Filling level measurement has exclusively been designed for plastic tanks 1 1 Suitable Accessories not supplied energy system EBL 99 and it s models and 1x panel cable 9 x 0 5 rod tank sensors 2x rod tank sensor and 2x seal ring art nr 126 007 possibly 2x checknut art nr 102 109 2x sensor cable 5 x 0 5 or tank sensors 10x tanksensor art nr 933 663 2x sensorcable 5 x 0 5 1 2 Technical Data operating voltage 12V 10 14 5V power supply by energy management system sizes 110 x 304 x 45 incl connectors H x W x D in mm front panel aluminium powder painted colour see enclosed table of measurements 2 Safety Information The electrical installation of the motorhome has to be in accordance with current DIN VDE and ISO regulations Manipulations will endanger the safety of persons and the vehicle Due to the above mentioned regu
2. eg being overseas necessary repairs can be carried out by a qualified workshop Unqualified repairs enforce expiration of warranty The manufacturer Schaudt GmbH disclaims it s liability and is therefore not liable to resulting damages note operating instruction manual is intended for the owner and has to come with the IT Schaudt GmbH Elektrotechnik amp App bau 88677 Markdorf Germany 08 03 2001 SEHN DT Operating Instruction Manual for Instrument Panel IT 992 SEKRUIDT Art Nr 930 420 Page5 5 7 Enclosures To this operating instruction manual belongs the enclosed the connection diagram and the dimension list to IT 992 art nr 930 420 This operating instructions manual with all it s enclosures must be delivered together with the IT 992 art nr 911 420 It must be part of the instruction manual if it is part of a system installed in a motorhome 7 1 EC declaration of conformity We hereby certify that the type of construction of the instrument panel IT 992 corresponds accordingly to approbiate provisions Electromagnetic compabitibility guide line 89 336 EWG mit nderung 92 31 EWG The EC declaration of conformity in original is available and can be looked at any time Manufacturer Schaudt GmbH Elektrotechnik amp Apparatebau Address Daimlerstra e 5 88677 Markdorf Germany note operating instruction manual is intended for the owner and has to come with the IT Schaudt GmbH Elektrotechnik
3. amp App bau 88677 Markdorf Germany 08 03 2001 COPYRIGHT 304 cabinet cut out 8 cabinet cut out 94 6x countersunk fixing holes see detail X mounting depth inclusive plug connections 45mm front panel aluminium powder painted ground colour titanium RAL 9007 print graphite black RAL 9011 size 1 2 Schaudt GmbH 7 950 420 DaimlerstraBe 5 88677 Markdorf Bodensee Postfach 1150 930420V1 Fn Telefon 07544 9577 0 COPYRIGHT rear_view 12V to fresh water tank load Lumberg MSFQ 0 6 pole awning light water pump etc to waste water tank shunt battery side Lumberg MSFQ 0 5 pole shunt load side 2x AMP male plugs 4 8x0 8 mains supply indicator negative camping battery sense to EBL starter battery Lumberg MSFQ 0 9 pole 12V_on 12V_ off 12V indicator nderungen nur ber A CAD Schaudt GmbH DaimlerstraBe 5 88677 Markdorf Bodensee 10708 connection diagram Art Nr oe ma instrument panel IT 992 ablage 93042x En
4. by using the battery voltage or filling level instrument Continous reading of indicating range from 30A discharge current red range to no current mid range to 30A charging current green range Evaluation of charging and discharging currents vehicle Is parked lS driving Is connected to mains supply current without mains supply runs on 230V reading runs on battery mobile roe 8 load no charge no charge Eom discharge of battery too much load or too much load or alternator defective alternator defective no load battery fully or nearly charged if battery fully or nearly charged if charging current decreases with charging current decreases with no load except refrigerator from no load from green range to zero green range to zero green only possible with battery is being charged battery is being charged range solar power supply up to over 30A possible up to 16A possible with additio nal charger up to 32A Inquiry of water tank filling level Indication of water tank filling levels by V Tank meter lower scale in steps of empty 1 4 1 2 3 4 and full Automatic illumination of the meter during inquiry Actuate switch in direction of Ex i Filling level of fresh water tank is shown Actuate switch in direction of Filling level of waste water tank is shown Note Inquiry of watertank filling levels is for temporary use only The utilized method of measurement is
5. and level surface by use of the six provided location holes Please refer to enclosed table of measurements for mounting si ze details 5 Electrical Installation Electrical installation of the instrument panel has to be executed by qualified personel only Electrical connection on the backside of the instrument panel according to enclosed connection in structions To Put Into Operation Maintenance 6 1 To Put Into Operation The instrument panel can be operated only in connection with a energy system and water tank fil ling level measurement accessories See section 1 1 Suitable Accessories After complete connection the instrument panel is operated by the EBL The appliance is put into operation as by following sequence Connect the EBL to mains supply switch the battery cut off switch into Ein position and actuate 12V main switch on instrument panel The the yellow LED 230V lights up if the energy system is connected to mains supply See user s manual 6 1 To Put Into Operation 6 2 Maintenance Malfunctions The IT 992 is maintenance free For cleaning of the front panel use a soft moisturized cloth with a mild detergent no methylated spirit paint thinner etc Liquids must not be allowed to get into the panel Should repairs be necessary please contact the service department of Schaudt GmbH ph 0049 0 7544 9577 16 eMail kundendienst schaudt gmbh de If it is not possible to see the manufacturer for service
6. its need to be switched on by actuating 12V main switch once Caution AN To avoid unnecessary discharge of the camping battery the 12V supply should be switched off when leaving the vehicle Inquiry of battery voltage Continous indication of battery voltage from 10 to 15 Volts by V Tank instrument upper scale Automatic illumination when used Actuate switch in direction of 2 Starter battery voltage is indicated Actuate switch in direction of Camping battery voltage is indicated 3 1 Evaluation of Battery Voltage vehicle Is parked IS driving ls connected to mains battery without mains supply supply voltage runs on battery mobile runs on 230V no load no charge no charge battery discharged N or N or N on load 12V system overloaded 12V system overloade battery possibly overloaded caution low level discharge caution low level discharge caution low level discharge 11 1Vto standard operation bad charging if for longer bad charging if for longer 13 2V if at rest it goes approx _ time time lt 12V battery discharged or or gt 12 8V battery full 12V system overloaded 12V system overloaded 13 3V to Jis allowed to happen only right battery is being charge attery is being charge a Pe supply 13 8V to impossible battery is being equalize battery is being equalize 14 4V charged charged gt 14 6V impossible battery is being overloaded ba
7. lations and safety rules manipulations are therefore prohibited The instrument panel IT 992 must not be modified The connection of the instrument panel has to be done by qualified personel only In the following text special notice should be paid to the signs shown below CAUTION Electrical current hazard warning i CAUTION General hazard warning 230V 3 Operating Instructions and Display 230V Mains Supply Indicator If yellow LED 230V lights up the energy system is connected to mains supply See user s manual of energy system section 6 1 To Put Into Operation Epe note operating instruction manual is intended for the owner and has to come with the IT Schaudt GmbH Elektrotechnik amp App bau 88677 Markdorf Germany 08 03 2001 SEHN DT Operating Instruction Manual for Instrument Panel IT 992 SEKRUDT Art Nr 930 420 Page 2 5 Turn on and off 12V supply of living area actuate switch with 12V symbol in direction of o o 12V supply of living area is turned on Green indicator lamp is on in direction of 0 o 12V supply of living area is turned off Green indicator lamp is off Note The circuits heater reserve output 4 base light automatic step are not switched by 12V main switch They are operative even if 12V supply is switched off Only after a energy system shut down by the battery cut off switch or after a battery change do this circu
8. not suitable for continous running or prolonged inquiries Caution Continous running or prolonged testing will damage rod tank sensors or tank sensors Note If the motor home is not on mains supply the power supply of the water pump should be turned off during extented periods of no use eg at night as the pump relay has a load current of approx 160mA This adds up to about 4Ah battery drain per day Caution Creepage current discharge of camping battery with pump switch on note operating instruction manual is intended for the owner and has to come with the IT Schaudt GmbH Elektrotechnik amp App bau 88677 Markdorf Germany 08 03 2001 SERN DT Operating Instruction Manual for Instrument Panel IT 992 SEKRUIDT Art Nr 930 420 Page 4 5 Switch on and off of awning ligh Actuate switch in direction of at Awning light is switched on Actuate switch in direction of 2o Awning light is switched off Please see user s manual of motor home manufacturer 4 Transport Storage Installation 4 1 Transport Storage The instrument panel should be stored and transported in a suitable packing and in dry environment only Storage temperature range 10 C to 50 C 4 2 Installation The instrument panel is designed for use in dry and sufficiantly ventilated environment within a temperature range of 10 C to 45 C It is designed to sink into a cabinet front and has to be fitted on to a stout
9. ttery is being overloaded regulator of alternator N charger defective defective N battery at rest means The camping battery was not used for several houres Possibly check volta ge in the morning without any load If battery voltage at restis lt 12 0V it might be totally dischar ged fi Caution Battery Damage Low level discharge might permanently damage the battery note operating instruction manual is intended for the owner and has to come with the IT Schaudt GmbH Elektrotechnik amp App bau 88677 Markdorf Germany 08 03 2001 SERM DT Operating Instruction Manual for Instrument Panel IT 992 SEKRUIDT Art Nr 930 420 Page 3 5 Red warning indicator Alarm blinks Optical warning at alarming low camping battery charge ALARM As soon as the camping battery voltage drops below 11 0V the red warning light Alarm starts blinking Any load should now be switched off immediately and the camping battery has to be recharged If camping battery voltage continues to sink and drops below 10 5V the battery monitor za module of the EBL switches all 12V load off IN See section 3 1 Battery Voltages and the respective sections of the EBL Battery Charge and Battery Monitor Module Display of charging current and discharging current of camping battery The charging and discharging current of the camping battery is displayed permanently by the STROM meter The current meter is automatically illuminated
Download Pdf Manuals
Related Search
Caution caution sign caution tape caution hot sign caution cones caution symbol caution emoji caution watch your step cautions caution synonym cautionary caution icon cautionary tale caution meaning caution tape png caution wet floor sign caution in spanish caution wet paint caution watch your step sign caution wet floor caution signs images caution clipart caution notice caution hero caution express caution mariah carey