User`s Manual 700, 1000, 1500 Watt Inverter

image

Contents

1. MARINCO USER S MANUAL INV10120700 INV20120700 INV30120700 INV10121000 INV20121000 INV10121500 INV20121500 INV30121500 INV10240700 INV20240700 INV10241000 INV10241500 INV20121500 Pure sine wave inverter ENGLISH PAGE 1 NEDERLANDS PAGINA 13 DEUTSCH SEITE 25 MARINCO FRANCAIS N85W12545 Westbrook Crossing CASTELLANO Falls WI 53051 ITALIANO Menomonee Falls ITALIANO www marinco com 10000006303 05 This section provides a brief BA overview of a basic stand alone installation of the Inverter However please review the entire manual for connection of additional features and to ensure best performance and years of trouble free operation Use isolated tools Read safety instructions page 3 Disconnect the electrical power Switch off all consumers Switch off all charging systems Remove the battery fuse Check with a suitable voltmeter whether the DC installation is voltage free Move the main switch of the Inverter to the OFF position SINE WAVE INVERTER Mount the Inverter with four screws to a solid surface Allow at least 10 cm 4 inch space around the apparatus QUICK INSTALLATION INSTRUCTIONS Connect the battery to the DC input Integrate a fuse holder in the positive battery wire but do not place the fuse yet Black wire NEG Connect e red wire to e black wire to Incorrect polarity will damage
2. DC input voltage too high GREEN uninterrupted GREEN slow blinking RED fast blinking RED slow blinking DC input voltage too low Internal temperature too RED intermittently blinking high RED uninterrupted Overload short circuit Maintenance No specific maintenance is required If necessary use a soft clean cloth to clean the Inverter Never use any liquids acids and or scourers Check the wiring on a regular base Defects such as loose connections burnt wiring etc must be corrected immediately DECOMMISSIONING Proceed as follows for decommissioning of the inverter 1 Move the main switch Figure 1 ref 1 to the OFF position 2 Remove the DC fuse Be sure that others can not reverse this action taken 3 Now the inverter can be demounted in a safe way TROUBLE SHOOTING USER S MANUAL 700 1000 1500 WATT INVERTER Consult an installer if you cannot solve the problem by means of the table below Problem No output voltage all LED indicators are off No output voltage STATUS LED ref 5 is slowly blinking green No output voltage STATUS LED ref 5 is fast blinking red No output voltage STATUS LED is slowly blinking red No output voltage STATUS LED is intermittently blinking red No output voltage STATUS LED is uninterruptedly lit red No output voltage STATUS LED is uninterruptedly lit green Inverter switches on and off STATUS LED is slowly blinking red Some loads
3. 0 5V 30 6V 0 5V balle O AN ee eee eee ee asa 14 3V 0 5V 14 3V 0 5V 28 6V 0 5V 14 3V 0 5V 28 6V 0 5V Halen ee eS ee Maximum allowed ripple on DC 5 RMS Input current sb cere 125A 125A 64A 125A 64A External DC fuse seg ie 200A 200A 100A 200A 100A Ree eee Pavey lt 3 450Ah gt 150Ah gt 100Ah gt 150Ah gt 100Ah ony uptosm Somm 1 0AWG 50mm 1 0AWG 35mm 2AWG 50mm 1 0AWG 35mm 2AWG No load power consumption Off mode OmA OmA OmA OmA OmA Power Saving Mode 0 28A 0 28A 0 15A 0 28A 0 15A ON Unom 1 45A 1 40A 0 70A 1 40A 0 70A a ar temperature Full specifications at ambient temperature 0 to 40 C 32 to 104 F P p Derating with 5 C 3 F at 40 to 60 C 104 to 140 F ee eee Shutdown at over temperature auto recover after cooling down a eae Ambient temperature 25 to 40 C 13 to 104 F may not meet specified Derating with 5 C 3 F at 40 C to 60 C 104 to 140 F tol Bee CEs p Shutdown at over temperature auto recover after cooling down Cooling Temperature and load regulated fan Non operating temperature Ambient temperature 30 C to 70 C 22 F to 158 F storage temperature aT Protected against humidity and condensing air by conformal coating on both sides of all PCB s Max eral ve NUMIONY 95 relative humidity non condensing Safety Meet UL458 EN 60950 1 EMC FCC class A EN55022 EN61000 3 2 EN61000 3 3 EN55024 e mark N A N A N A N A N A Protections Overload sh
4. 10 cm 4 inch around the Inverter Do not install the Inverter in the same compartment as the batteries Do not mount the Inverter straight above the batteries because of possible corrosive sulphur fumes Before you start Figure 2 rear side Be sure that the output of the supplying source battery is switched off during installation Also be sure that no consumers are connected to the battery during installation to prevent hazardous situations Before installing the Inverter make sure the main switch Figure 1 ref 1 is set to the OFF position Check that the battery voltage is the same as the input voltage of the Inverter e g 24V battery for a Grounding Remote operation point switch option Inverter 24V input voltage Also check that the output voltage satisfies loading requirements A DC fuse holder must be integrated in the positive wiring The DC fuse should be placed last of all Use four 4 5mm No 8 screws to mount the Inverter to a solid surface See Figure 3 Wiring Connect DC wiring as shown in Figure 2 the black terminal 9 NEG to the negative pole of the power source battery the red terminal 8 POS to the positive pole of the power source battery Integrate a DC fuse holder in the positive wiring but do not place the fuse yet Assemble the DC wiring exactly as indicated Do not place anything between the ring terminal and the terminal surface Make sure that all DC
5. by switching the main switch ref 1 off and on again Press the reset button of the GCFI Figure 1 ref R Reduce the length of the DC cables or use cables with a larger gauge Disconnect the load and recharge the battery Tighten the connections burnt cables must be corrected immediately Check the specified input frequency of the load with the output frequency of the Inverter If necessary adjust the output frequency See DIP SWITCH SETTINGS USER S MANUAL 700 1000 1500 WATT INVERTER ENGLISH SPECIFICATIONS 700W models Model Inverter 12 700 120V US 24 700 120V US 12 700 230V Br 12 700 230V EU 24 700 230V EU Part number INV20120700 INV20240700 INV30120700 INV10120700 INV10240700 Baten 2 the Conversion of a DC voltage to a pure AC sine wave voltage Supplier Marinco ingut voltage 12VDC 24VDC 12VDC 12VDC 24VDC p ge 10 5 15 0VDC 21 0 30 0VDC 10 5 15 0VDC 10 5 15 0VDC 21 0 30 0VDC Nom Power Tamb 40 C coso 1 700W 700W 700W 700W 700W Max peak load 1400W 1400W 1400W 1400W 1400W Output waveform True sine wave THD lt 3 Maximum efficiency 89 91 91 91 93 Output voltage 120V 5 120V 5 230V 3 230V 3 230V 3 Frequency selectable 60Hz 0 05Hz 60Hz 0 05Hz 60 Hz 0 05Hz 50 Hz 0 05Hz 50 Hz 0 05Hz AC outlet GFCI Schuko UK Australia Universal Dimensions See chapter Dimensions Weight 2 7 kg 5 4 Ibs 2 7 kg 5 4 Ibs 2 7 kg 5 4 Ibs 2 7 kg 5 4 Ibs 2 7 kg 5 4 Ibs Protection degree IP21 I
6. costs of repair and or replacement of the product by Marinco only Costs for installation labour or shipping of the defective parts are not covered by this guarantee EC DECLARATION OF CONFORMITY We Manufacturer Marinco Address USA Mastervolt B V Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Represented in the EU by Address declare under our sole responsibility that products INV10120700 Marinco Inverter 12 700 230V EU INV10240700 Marinco Inverter 24 700 230V EU INV10121000 Marinco Inverter 12 1000 230V EU INV10241000 Marinco Inverter 24 1000 230V EU INV10121500 Marinco Inverter 12 1500 230V EU INV10241500 Marinco Inverter 24 1500 230V EU ENGLISH For making an appeal on warranty you can directly contact your supplier mentioning your complaint application date of purchase and part number serial number The standard guarantee period is 2 years LIABILITY Marinco cannot be held liable for e Possible errors in this manual and the consequences of these e Damage due to use that is inconsistent with the purpose of the product N85 W12545 Westbrook Crossing Menomonee Falls WI 53051 are in conformity with the provisions of the following EU directives 2004 108 EC EMC Directive 2006 95 EC Low Voltage Directive 2011 65 EU RoHS Directive The following harmonised standards have been applied EN 55022 2010 EN 55024 2010 Generic emission standard Generic Immunity standard Low volta
7. whether all connections are connected correctly before placing the fuse e Do not connect the AC output of the inverter to an incoming AC source e Never connect the Inverter in parallel with any other inverter e Never open the housing as high voltages may be present inside UNPACKING The delivery consists of the following parts e The inverter e This user s manual e Four ring terminals After unpacking check the Inverter for possible damage Do not use the Inverter if it is damaged If in doubt contact your supplier NEUTRAL GROUNDING For safe installation e The chassis ground terminal see Figure 2 ref 7 must be connected to the central grounding point of the vehicle ship 1 Main switch 3 On p lt Off q Remote Figure 1 Front side LED indicators oooi J _ e The neutral conductor N of the AC output of the Inverter must be connected to the safety ground PE GND and a ground fault circuit interrupter GFCI must be integrated in the wiring of the AC output See below for model specific information Refer to locally applicable regulations on these issues 120V models With the 120V models the neutral conductor of the AC output circuit of the Inverter is internally connected to the safety ground during inverter operation automatically and a ground fault circuit interrupter GFCI is already integrated in the AC output circuit of the I
8. N55024 N A N A N A e mark Protections Overload short circuit over under voltage over temperature Internal fuse reversed polarity may lead to permanent damage Reversed polarity USER S MANUAL 700 1000 1500 WATT INVERTER ENGLISH SPECIFICATIONS 1500W models Model Inverter 12 1500 120V US 12 1500 230V Br 24 1500 230V Br 12 1500 230V EU 24 1500 230V EU Part number INV20121500 INV30121500 INV30241500 INV10121500 INV10241500 Function of the apparatus Conversion of a DC voltage to a pure AC sine wave voltage Supplier Marinco odaie 12VDC 12VDC 24VDC 12VDC 24VDC p ge 10 5 15 0VDC 10 5 15 0VDC 21 0 30 0VDC 10 5 15 0VDC 21 0 30 0VDC Nom Power Ta 40 C cose 1 1500W 1500W 1500W 1500W 1500W Max peak load 3000W 3000W 3000W 3000W 3000W Output waveform True sinewave THD lt 3 Maximum efficiency 88 90 93 90 93 Output voltage 120V 5 230V 3 230V 3 230V 3 230V 3 Frequency selectable 60Hz 0 05Hz 60Hz 0 05Hz 60 Hz 0 05Hz 50 60 Hz 0 05Hz 50 60 Hz 0 05Hz AC outlet GFCI Schuko UK Australia Universal Dimensions See chapter Dimensions Weight 4 8kg 10 6Lbs 48kg 10 6Lbs 4 8kg 10 6Lbs 4 8kg 10 6Lbs lt 4 8kg 10 6Lbs Protection degree IP21 IP21 IP21 IP21 IP21 Technology HF Switch mode SE a A A E 10 2V 0 5V 20 3V 0 5V 10 2V 0 5V 20 3V 0 5V _battery O De a 12 7V 0 5V 12 7V 0 5V 25 2V 0 5 12 7V 0 5V 25 2V 0 5 Shut down voltage high 45 3y 40 5V 15 3V 0 5V 30 6V 0 5V 15 3V
9. P21 IP21 IP21 IP21 Technology HF Switch mode SE a A A E 20 3V 0 5V 10 2V 0 5V 10 2V 0 5V 20 3V 0 5V ao aE E E AR ea ee ee nee ee ae Be leas 12 7V 0 5V 25 2V 0 5 12 7V 40 5V 12 7V 0 5V 25 2V 0 5 Shut down voltage high 45 3y 40 5V 30 6V 0 5V 15 3V 0 5V 15 3V 0 5V 30 6V 0 5V SA ee eA I SS A U asa 14 3V 0 5V 28 6V 0 5V 14 3V 0 5V 14 3V 0 5V 28 6V 0 5V Dattery a Ce Maximum allowed ripple on DC 9 RMS Input current H mihalload 64A 32A 64A 64A 32A External DC fuse f dulred 100A 50A 100A 100A 50A Ree cera lt 2 00Ah gt 55Ah gt 100Ah gt 100Ah gt 55Ah Do pable up tosm 25mm 4AWG 16mm 6AWG 25mm 4AWG 25mm 4AWG 16mm BAWG No load power consumption Off mode OmA OmA OmA OmA OmA Power Saving Mode _ 0 25A 0 15A 0 25A 0 25A 0 15A ON Unom 1 25 A 0 64A 1 20A 1 20A 0 60A a ar temperature Full specifications at ambient temperature 0 to 40 C 32 to 104 F P p Derating with 5 C 3 F at 40 to 60 C 104 to 140 F ee pecified Shutdown at over temperature auto recover after cooling down a eae Ambient temperature 25 to 40 C 13 to 104 F may Hot meetepeoifed Derating with 5 C 3 F at 40 C to 60 C 104 to 140 F tol Bee mee p Shutdown at over temperature auto recover after cooling down Cooling Temperature and load regulated fan Non operating temperature Ambient temperature 30 C to 70 C 22 F to 158 F storage temperature aT Prote
10. connections are tight Recommended torque 11 7 13 Nm 104 115 InLbs Chassis ground Use a cable AWG8 6 mm to connect the CHASSIS GROUND terminal 7 to the central ground Remote operation switch option If you want to operate the Inverter on a remote location you can install a switch as indicated in Figure 2 When the contact is closed the Inverter is switched on ENGLISH USER S MANUAL 700 1000 1500 WATT INVERTER COMMISSIONING AFTER INSTALLATION 1 Check the polarity of the DC connections Do not place the DC fuse if the polarity is not correct 2 Place a DC fuse see SPECIFICATIONS in the fuse holder When placing this fuse a spark may occur caused by internal capacitors of the Inverter This is normal 3 AC voltage the load can be plugged into the AC output Figure 1 ref 2 directly OPERATION Switching on Move the main switch Figure 1 ref 1 to ON The Inverter will start a self test indicated by two beeps from the buzzer and flashing LED indicators This may last for approximate two seconds Finally the buzzer will produce another beep and the Inverter will switch on indicated by two green LED indicators Now the Inverter is ready to supply load connected to the AC output Switching off Move the main switch Figure 1 ref 1 to the OFF position Note that switching off the Inverter does not break the connection to the batteries Remote operation The Inverter can be operat
11. cted against humidity and condensing air by conformal coating on both sides of all PCB s Max eral ve NUMIONY 95 relative humidity non condensing Safety Meet UL458 EN60950 1 EMC FCC class A EN55022 EN61000 3 2 EN61000 3 3 EN55024 e mark N A N A N A N A N A Protections Overload short circuit over under voltage over temperature Reversed polarity Internal fuse reversed polarity may lead to permanent damage ENGLISH USER S MANUAL 700 1000 1500 WATT INVERTER SPECIFICATIONS 1000W models 12 1000 120V USA Model Inverter Part number Function of the 12 1000 230V EU INV10121000 24 1000 230V EU INV20121000 INV10241000 Conversion of a DC voltage to a pure AC sine wave voltage apparatus Supplier Marinco 12VDC 10 5 15 0VDC Input voltage Nom Power Tamb 40 C coso 1 Max peak load Output waveform Output voltage Frequency selectable AC outlet Dimensions Weight Protection degree Technology Shut down voltage low batte Restart voltage low batte Shut down voltage high batte Restart voltage high batte Maximum allowed ripple on DC Input current nominal load External DC fuse required Recommended battery capacity 12VDC 10 5 15 0VDC 24VDC 21 0 30 0VDC 1000W 1000W 1000W lamb 74I V COSO l 2000W 2000W 2000W True sine wave THD lt 3 Maximum efficiency 89 91 94 120V 5 230V 3 230V 3 60Hz 0 05Hz 50 Hz 0 05Hz 50 Hz 0 05Hz GFCI Schuko UK Aust
12. ed on a remote location by means of an optional remote switch Move the main switch Figure 1 ref 1 to the REMOTE position When the remote contact is closed the Inverter is switched on GFCI 120V models only In case of a ground fault the Ground Fault Circuit Interrupter GFCI trips and cuts off the AC output To switch on the AC output again push the reset button Figure 1 ref R LED indicators See Figure 1 The operation of the inverter is made visible by means of LED indicators 3 4 and 5 INPUT LEVEL ref 3 displays the input voltage of the inverter Input voltage V Indication of the LED 12V models 24V models RED blinking slow 10 3 10 6 20 5 21 2 RED 10 6 11 0 21 2 21 8 ORANGE 11 0 12 1 21 8 24 1 GREEN 12 1 14 2 24 1 28 6 ORANGE blinking 14 2 15 0 28 6 30 0 RED blinking fast gt 15 0 gt 30 0 LOAD LEVEL ref 4 shows the output load level lt a Power level W Model 700W 1000W 1500W LED off 0 56 0 80 0 120 GREEN 56 230 80 330 120 495 ORANGE 230 525 330 750 495 1125 RED 525 672 750 960 1125 1450 RED blinking gt 672 gt 960 gt 1450 STATUS ref 5 shows the operation mode of the inverter As long this LED isn t illuminated red no failure is detected the inverter is operating normally If an error occurs it is detected by the apparatus itself the STATUS LED turns red Indication of the LED Meaning Power OK Power saving mode see DIP SWITCH SETTINGS
13. ge standard Amsterdam 19 December 2013 Manager New Product Development EN 60950 1 2006 A11 2009 A1 2010 11 MARINCO N85W12545 Westbrook Crossing Menomonee Falls WI 53051 Phone 800 307 6702 or 262 293 1700 Fax 262 293 7022 Email info Marinco com
14. like televisions and clocks do not operate correctly Possible cause Main switch ref 1 is set to the OFF position Main switch ref 1 is set to REMOTE but no remote present The remote switch is off if applied DC fuse blown Inverter is in power saving mode DC input voltage too high DC input voltage too low flat battery AC Output is overloaded Airflow insufficient AC output overloaded or short circuit 120V models only internal GFCI tripped DC input voltage too low because of voltage drop across the DC cables due to too long or too narrow cables Flat battery Loose or corroded connections Wrong setting of output frequency What to do Set the main switch ref 1 in ON position Set the main switch ref 1 in ON position Close the remote operation switch Replace the fuse Increase the load or adjust the power setting mode See DIP SWITCH SETTINGS Check battery voltage switch off charger The inverter will switch on again when the input voltage is lt 14 3 lt 28 6V Charge the battery The inverter will switch on again when the input voltage is gt 12 7V gt 25 2V Reduce the load and let the inverter cool down The inverter will switch on again when the internal temperature is lt 45 C 113 F Check the airflow through the inverter The operation of the cooling fan may not be blocked Reduce the load and or check the AC wiring for possible short circuits Then reset the inverter manually
15. nverter 230V models With the 230V models there is no connection made inside the inverter between either the line or neutral conductor to the safety ground DIP SWITCH SETTINGS See Figure 1 ref 6 Under normal circumstances there is no need to change the default settings of the DIP switches the inverter is immediately ready for use To save energy from the battery in no load operation DIP switches S1 S2 and S3 can be used to adjust the Power Saving Mode The Power Saving Mode scans the output and when it detects a load which is higher than the selected threshold value the inverter is switched on automatically Power Saving Mode S1 S2 S3 Model 700 1000 1500 DISABLE DISABLE 0 0 0 15W 20W 1 0 0 25W 40W 0 1 0 40W 55W 1 1 0 SOW 75W 0 0 1 65W 95W 1 0 1 75W 115W 0 1 1 85W 135W 1 1 1 DIP switch S4 is used to select the output frequency Output frequency S4 50Hz 0 60Hz 1 AC output 120V models AC output 230V models USER S MANUAL 700 1000 1500 WATT INVERTER INSTALLATION Choosing a location to install Install the Inverter in a well ventilated room protected against rain Snow spray vapour bilge moisture and dust Ambient temperature 25 40 C 13 104 F Never use the Inverter at a location where there is danger of gas or dust explosions Mount the Inverter in such a way that obstruction of the airflow through the ventilation openings is prevented No objects must be located within a distance of
16. ort circuit over under voltage over temperature Reversed polarity Internal fuse reversed polarity may lead to permanent damage USER S MANUAL 700 1000 1500 WATT INVERTER DIMENSIONS Are 19 O Sg oN 700 Watt 163 6 4 HEE 1000 Watt 166 6 5 ess 1500 Watt 175 6 9 239 Pee Tie OLL ge 700 Watt 151 5 9 h oo 1000 Watt 154 6 0 HEE 1500 Watt 163 6 4 n _ SINE WAVE INVERTER 8 00 LO LO Um E35 oooi 1388 Mm q tf 700 Watt 179 7 0 1000 Watt 182 7 2 1500 Watt 191 7 5 Figure 3 Dimensions in mm inch ORDERING INFORMATION Part number Description INVR 1 Remote panel for Marinco inverter 10 USER S MANUAL 700 1000 1500 WATT INVERTER GUARANTEE TERMS Marinco guarantees that this product was built according to the legally applicable standards and stipulations During production and before delivery all products are exhaustively tested and controlled If you fail to act in accordance with the regulations instructions and stipulations in this users manual damage can occur and or the product will not fulfil the specifications This may mean that the guarantee will become null and void The guarantee is limited to the
17. ralia Universal See chapter Dimensions 4 0 kg 8 8 Ibs 4 0 kg 8 8 lbs 4 0 kg 8 8 Ibs IP21 IP21 IP21 HF Switch mode 10 2V 0 5V 10 2V 0 5V 20 3V 0 5V 12 7V 0 5V 12 7V 0 5V 25 2V 0 5V 15 3V 0 5V 15 3V 0 5V 30 6V 0 5V 14 3V 0 5V 14 3V 0 5V 28 6V 0 5V 5 RMS 92A 92A 46A 150A 150A 80A 2120Ah 2120Ah 2100Ah DC cable up to 3m 10ft No load power 35mm 2AWG 35mm 2AWG 25mm 4AWG consumption Off mode OmA OmA OmA Power Saving Mode 0 25A 0 25A 0 15A 1 43A 1 25A 0 65A ON Unom Operating temperature Full specifications at ambient temperature 0 to 40 C 32 to 104 F specified will meet specified tolerances Derating with 5 C 3 F at 40 to 60 C 104 to 140 F Shutdown at over temperature auto recover after cooling down Practical operating temperature may not meet specified tolerances Ambient temperature 25 to 40 C 13 to 104 F Derating with 5 C 3 F at 40 C to 60 C 104 to 140 F Shutdown at over temperature auto recover after cooling down Cooling Non operating temperature storage temperature Relative humidity Temperature and load regulated fan Ambient temperature 30 C to 70 C 22 F to 158 F Protected against humidity and condensing air by conformal coating on both sides of all PCB s Max 95 relative humidity non condensing Safety EMC Meet UL458 EN60950 1 FCC class A EN55022 EN61000 3 2 EN61000 3 3 E
18. the Inverter 6 Connect the AC load to the AC socket 120V 230V For safe installation e The chassis ground terminal see Figure 1 reference 7 must be connected to the central grounding point of the vehicle ship The neutral conductor N of the AC output of the Inverter must be connected to the safety ground PE GND and a ground fault circuit interrupter GFCI must be integrated in the wiring of the AC output Refer to section NEUTRAL GROUNDING of this user s manual Q Check all wiring If all wiring is OK e Place the inverter fuse e Switch on the Inverter ENGLISH USER S MANUAL 700 1000 1500 WATT INVERTER PRODUCT DESCRIPTION AND APPLICATION The Marinco inverters convert a DC voltage to a pure AC sine wave voltage SAFETY INSTRUCTIONS WARNING Before using the Inverter read and save the safety instructions e Use the Inverter following the instructions and specifications stated in this manual e Connections and safety features must be executed according to the locally applicable regulations e Operation of the Inverter without proper grounding may lead to hazardous situations e Use DC cables with an appropriate size Integrate a fuse in the positive wiring and place it nearby the battery Refer to the specifications e If the positive and negative wires on the DC input battery are exchanged the Inverter will be damaged Damage of this kind is not covered by guarantee Check