Home

User Manual - 3DISC Imaging

image

Contents

1. sssssisssiissessisseee seen 32 6 2 Repair Service essisseisssssssse seen ases nnns n nnns n ansa arn sna rasa asas a ns 32 6 3 Out of Warranty Repair Service esses 32 04 SNP ucEE ETE 33 Chapter 7 Technical ASSISTANCE sees eene 34 User Manual FireCR Flash TM 401 EN Chapter 1 Introduction Thank you very much for deciding on FireCR Flash Computed Radiography Reader The FireCR Flash System is ideal for a wide range of Computed Radiography examinations in specialty practices such as chiropractors podiatrists and orthopedists The FireCR Flash can be configured for nearly every clinical application and is designed for full DICOM connectivity and allows user to setup the system to capture high quality X ray images of any body parts with minimal steps including reading processing displaying and sending of the high quality image All imaging parameters are optimized resulting in digital images that can be enhanced enlarged duplicated and sent to any location as a DICOM 3 0 file format in seconds with no loss of resolution Combine the system with reusable phosphor screen equipped FireCR Flash cassettes and portable X ray equipment it can be used for X ray exams everywhere it is needed e g nursing facilities forensic institutions employee screenings etc The FireCR Flash System is ideal for Computed Radiography examinations in busy clinics and specialty pra
2. gt 95 dip in Ut Mains power quality should be Interruptions and for O 5cycle for 0 5cycle that of a typical commercial or Voltage variations hospital environment If the on power supply 40 Ur 60 dip in Ur 40 Ur 6096 dip in Ur user of the BSVD 1000 system input lines for 5 cycle for 5 cycle requires continued operation IEC 61000 4 11 during power mains 70 Ur 30 dip in UT 70 Ur 80 dip in Ur interruptions it is for 25 cycle for 25 cycle recommended that the FireCR Flash system be powered lt 5 Ur 959 dip in Ur 596 Ur 9596 dip in Ur from an uninterruptible power for5s for5s supply or a battery User Manual FireCR Flash Conducted RF 3 Vrms 3 Vrms IEC 61000 4 6 150 kHz to 80 MHz 150 kHz to 80 MHz Radiated RF 3 V m 3 V m IEC 61000 4 3 80 0 MHz to 2 5 GHz 80 0 MHz to 2 5 GHz Note 1 Ur is the A C mains voltage prior to application of the test level Note 2 At 80 MHz and 800 MHz the higher frequency range applies TM 401 EN Portable and mobile RF communications equipment should be used no closer to any part of the FireCR Flash system including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Recommended separation distance 3 5 d WP 80 MHz to 800 MHz E14 d TUE P 800 MHz to 2 5 GHz Ay Where P is the maximum output power rating of the transmitter in watts W ac
3. 401 EN Warnings and Used Symbols To ensure the safety of patients staff and other persons any changes to software and hardware delivered by 3D Imaging amp Simulations Corp may only be made with prior written permission from 3D Imaging amp Simulations Corp Please read the respective manuals of the connected software such as acquisition and diagnostic software before starting to use the system The following symbols will be used throughout this manual DANGER General prohibition indication The functionality of the system can be destroyed in the case of incorrect use If unauthorized changes have been made to delivered system and accessories the warranty by 3D Imaging amp Simulations Corp becomes void 3D Imaging amp Simulations Corp will not accept any responsibility or liability for the proper functioning of the product in such a case DANGER General mandatory action manual The functionality of the system can be destroyed in the case of incorrect use If unauthorized changes have been made to delivered system and accessories the warranty by 3D Imaging amp Simulations Corp becomes void 3D Imaging amp Simulations Corp will not accept any responsibility or liability for the improper functioning of the product in such a case WARNING The functionality of the system can be limited in the case of incorrect use Hints that require special attention NOTE Notes represent information that is important to kn
4. in environmental contamination When disposing of this equipment contact 3D Imaging amp Simulations Corp s representative or related organs of government Do not dispose of any part of this equipment without consulting a 3D Imaging amp Simulations Corp s representative first 3D Imaging amp Simulations Corp does not assume any responsibility for damage resulting from disposal of this equipment without consulting 3D imaging amp Simulations Corp WARNING Use the device passed IEC60950 1 or IEC60601 1 for the product connected via USB port User Manual FireCR Flash TM 401 EN Chapter 3 Setting Up WARNING Unsuitable Installation Sites Locations with excessive humidity or dust Locations subject to high temperature Locations subject to shaking or vibration Locations exposed to considerable electrical or magnetic noise or other forms of electromagnetic energy Locations with poor heat radiation 3 1 Tabletop Mount The reader must be placed on a rigid and flat desk or tabletop with at least 10 cm 4 inch free space on both sides 20 cm 8 inch on rear side and 50 cm 20 inch on front side for cassette insertion Its space requirements are shown below In case that desk or table is not flat adjust feet under the reader for leveling The reader weighs approximately 19 5 kg 42 4 lbs and requires two persons to lift Carefully place the reader into its final position Free space of 50 cm 20 in
5. is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The user of the FireCR Flash system can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile HF communications equipment transmitters and the FireCR Flash system as recommended below according to the maximum output power of the communications equipment Separation distance m according to frequency of transmitter Rated maximum output 800 pi to 2 5 power W of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 028 074 2 33 EL 25 30 For transmitters rated at a maximum STENT power not listed poe the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer Note 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Immunity and Compliance Level Immunity test IEC 60601 Test Level Actual Immunity Level Compliance Level Conducted RF 3 Vrms 150 kHz to 80 3 Vrms 150 KHz to 80 3 Vrms 150 KHz to 80 Radiated RF 3 V m 80 MHz to 2 5 3 V m 80 MHz to 2 5 3 V m 80 MHz to 2 5 User Manual Fire
6. product with the protective cover removed from Laser Reader assembly The reflected beam although invisible can damage your eyes When using this product these basic safety precautions should always be followed to reduce risk of fire electric shock and personal injury Warning Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure User Manual FireCR Flash TM 401 EN Chapter 6 Warranty and Repair Service 6 1 Standard Warranty 3D Imaging amp Simulations Corp warrants its non consumable hardware products to be free from defects in materials and workmanship The warranty covers the cost of parts and labor to repair the product Please keep the shipping container for future use Products returned to the factory for repair should be properly packaged To obtain warranty service follow the procedure described in the Repair Service section Failure to do so will cause long delays and additional expense to the customer The warranty is valid when the product is used for its intended purpose and does not cover products which have been modified without written permission from 3D Imaging amp Simulations Corp or which have been damaged by abuse accident or connection to incompatible equipment This warranty is in lieu of all other warranties expressed or implied 6 2 Repair Service The company reserves the right to cease providing repair mai
7. stage Laser Mirror and DC Motor which are required to radiate laser onto imaging plate DC Motor which assures proper insertion of the cassette User Manual FireCR Flash TM 401 EN Chapter 5 Symbols Manufacturer Date of Manufacture ot ee Equipment Power OFF Warning Consult Accompany Documents General mandatory action manual General prohibition indication e Directive on Waste Electrical and Electronic Equipment Authorized Representative in the European Community Keep Dry User Manual FireCR Flash TM 401 EN Fragile Handle with care This side up Non ionizing electromagnetic radiation FCC Mark Medical Equipment WITH RESPECT TO ELECTRIC SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL60601 1 CAN CSA CSS 2 No 601 1 3SE3 Q 5 1 Manufacturer s Declaration Electromagnetic Emission The FireCR Flash system is intended for use in the electromagnetic environment specified below The customer or the user of FireCR Flash system should assure that it is used in such an environment HF emissions The FireCR Flash system uses RF energy only CISPR 11 for its internal function Therefore Its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions Class B The Model FireCR Flash is suitable for use in all CISPR 1 1 establishments including domestic Harmonics emission A establishments a
8. user would like to avoid but it is inexpensive compared to the cost of repairing an instrument that has sustained shipping damage It is user s responsibility to package the system properly before shipping If the packaging is inadequate and the system is damaged during shipping the shipper will not honor user s claim for compensation User Manual FireCR Flash TM 401 EN Chapter 7 Technical Assistance If user has any questions about installing or using the device contact your 3D Imaging amp Simulations Corp representative or your local dealer 3D Imaging amp Simulations Corp Bldg 1 48 Yuseong daero 1184 beon gil Yuseong gu Daejeon 305 345 Korea Tel 82 42 931 2100 Fax 82 42 931 2299 www 3DlSCimaging com User Manual FireCR Flash TM 401 EN Appendix Installation Report Please complete this report at the time of installation and submit the completed form signed by customer to Fax 82 42 931 2299 E mail support 3DISCimaging com Date of Installation Customer Information Hospital Institute Installer Information Company JJ 0000000000000 O O Name o Fa E mail System Information FireCR Flash CR Reader System S N Installer s Signature Date Customer s Signature Date
9. x 2150 Pixel Matrix IP 35cm x 43cm Standard 1200 x 1500 Pixel Matrix IP 24cm x 30cm l Standard 900 x 1200 Pixel Matrix IP 18cm x 24cm l 35cm x 43cm 24cm x 30cm 18cm x Accepted Cassette Size s AD Convert Resolution 16 bit Eraser Embedded Computer Interface USB 2 0 Ethernet Dimensiens 456 x 803 x 137mm 17 9 x 31 6 x 5 4inch l 19 5kg egni 42 4lbs Power Requirement 100 240V 50 60Hz System Configuration Tabletop or Wall Mount Image File Format DICOM 3 0 Specifications subject to change without notice Specific results may vary since operating conditions fluctuate User Manual FireCR Flash TM 401 EN 4 2 Operation Conditions Indoor use only Operating Temperature 15 C 30 C 59 F 86 F Leni eiie Relative Humidity 15 95 non condensing Storage Temperature 10 C 50 C 14 F 122 F Strace Humiiy Storage Atmospheric Pressure Transportation Temperature 10 C 50 C 14 F 122 F Transporation Fumidiy Transportation Atmospheric Pressure Installation Category Pollution Degree Ingress of Liquids IPXO Altitude Up to 2 000m Protective Class Equipment Maintenance No user maintenance is required and no user service is allowed Please contact technical support if there is a problem Cleaning Do not try to clean inside of the reader Wipe outside of the reader for dust removing with soft and dry cloth DANGER There are no user serviceable parts inside the re
10. 64 USA Tel 1 703 430 6080 E mail info 3DISCimaging com EC REP 3DISC Europe Gydevang 39 41 3450 Alleroed Denmark Tel 45 88 276 650 E mail info 3DISCimaging com User Manual FireCR Flash TM 401 EN The device complies with Part 15 of the FCC Rules Operation is subject to the condition that this device does not cause harmful interference NOTE This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction may cause harmful interference to radio communication However there is no guarantee that interference will not occur in a particular installation If this equipment dose cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help User Manual FireCR Flash TM
11. CR Flash TM 401 EN 5 3 Guidance and Manufacturer s Declaration Electromagnetic Immunity The FireCR Flash system is intended for use in the electromagnetic environment specified below The customer or the user of FireCR Flash system should assure that it is used in such an environment IEC 60601 Electromagnetic environment Immunity test Compliance level Test level guidance Conducted RF 3 Vrms 3 Vrms FireCR Flash system must be used IEC 61000 4 6 150 kHz to 80MHz 150 kHz to 80 MHz only in a shielded location with a minimum RF shielding effectiveness and for each cable that enters the shielded location with a minimum RF shielding effectiveness and for each cable that enters the shielded location Radiated RF 3 V m 3 V m Field strengths outside the shielded IEC 61000 4 3 80 0 MHz to 2 5GHz 80 0 MHz to 2 5GHz location from fixed RF transmitters as determined by an electromagnetic site survey should be less than 3V m a Interference may occur in the vicinity of equipment marked with the following symbol Co Note 1 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Note 2 It is essential that the actual shielding effectiveness and filter attenuation of the shielded location be verified to assure that they meet the minimum specification a Field strengths from fixed transmitters such as base stations for r
12. FIFeCR flash User Manual Computed Radiography Reader Doc No TM 401 EN Rev 1 2 2 Apr 2015 Part No CR FPM 44 001 EN 3DISC FireCR Quantor and the 3D Cube are trademarks of 3D Imaging amp Simulations Corp South Korea and its affiliates All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement The data in this publication are for illustration purposes only and do not necessarily represent standards or specifications which must be met by 3D Imaging amp Simulations Corp All information contained herein is intended for guidance purposes only and characteristics of the products and services described in this publication can be changed at any time without notice Products and services may not be available in your local area Please contact your local sales representative for availability information 3D Imaging amp Simulations Corp strives to provide as accurate information as possible but shall not be responsible for any typographical error Copyright 2014 3D Imaging amp Simulations Corp All rights reserved User Manual FireCR Flash TM 401 EN Contact 3DIS IMAGING 3D Imaging amp Simulations Corp Bldg 1 48 Yuseong daero 1184 beon gil Yuseong gu Daejeon 305 345 Korea Tel 82 42 931 2100 Fax 82 42 931 2299 Website www 3DISCimaging com E mail info 3DISCimaging com 3DISC Americas 22560 Glenn Dr Suite 116 Sterling VA 201
13. ader The reader should only be opened and serviced by qualified service personnel Failure to heed this warning may result in injury to service personnel or damage to equipment and void any and all warranties If there is a service problem please contact 3D Imaging amp Simulations Corp or authorized dealer User Manual FireCR Flash TM 401 EN 4 3 Operating Instructions 4 3 1 Turn on the Reader Turn on the reader Power switch is on the rear side of the reader DANGER SO This device uses laser Avoid looking inside of the scanner 4 3 2 Turn on the Computer Turn on the computer Acquisition and Diagnostic Software must be installed before operate the reader 4 3 3 Cassette Insert and Eject Insert the cassette to the entrance of the reader and push gently until it reaches to the protection wall inside of the reader Green indication LED is on when the cassette is inserted correctly Insertion direction of the cassette must be parallel to the reader Cassette can be ejected when scanning and erasing are completed Gently pull back the cassette and ejection direction of the cassette must be parallel to the reader WARNING Do not insert the cassette in wrong direction or upside down when it is being inserted Cassette insertion direction is marked on the cassette 4 83 4 Getting a Scanned Image To getting a scanned image refer to Acquisition and Diagnostic Software manual User Manual FireCR Flas
14. adio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength outside the shielded location in which the EUT is used exceeds 3V m the EUT should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as relocating the EUT or using a shielded location with a higher RF shielding effectiveness and filter attenuation User Manual FireCR Flash TM 401 EN 5 4 Laser Safety Statement The Computed Radiography Reader is Certified in the U S to Conform to the Requirements of DHHS 21 CFR chapter 1 Subchapter J for Class I 1 Laser Products and Elsewhere is Certified as a Class l 1 Laser Product Conforming to the Requirements of IEC 60825 1 2007 Class l 1 Laser Products are not Considered to be Hazardous The Laser System and Computed Radiography Reader are Designed so there is never any Human Access to Laser Radiation above a Class I 1 level during normal Operation user Maintenance or Prescribed Service Condition Wavelength 658 nm Typ Beam Divergence Paraller 9 5 degrees 2 5 2 5 Perpendicular 17 degrees 3 3 Maximum Power of Energy Output 80 mW CW WARNING Never operate or service the
15. be operated in a radiological environment by qualified staff FireCR Flash is not approved for the acquisition of mammographic image data User Manual FireCR Flash TM 401 EN Index of contents Chapter 1 Introduction 1cccceccceeeccnsenseeccsensnecsesesseeseesessnsesneessnses 9 Chapter 2 Unpacking 1ccccccccveccceecceeccnseceeesssessnessesessessseesseseenes 11 2 1 IHSDPECHOR OP Ed cussuiecnveten nieni Md NUM MERC RUNS 11 2 2 Identify the COMPONENMS scccccseccccseeccceeceseecesueeessueeesseeesseeeeas 11 Chapter 3 Setting Up ossis eene 13 ale Taoa MOUN MORE CEN c E RCRUM 13 3 2 Wall Mount CODIOE assensus nets ek EMI PAR FXNVRRH TERME FREE Ko ERRO EVE PRERS 14 3 3 Identify Important F Qtures cccccccsseecseeccneeseessusesusessuessuseseesans 16 3 3 1 Reader Connecting Part esses eene 16 3 3 2 Header Status Indication LED eseeseeeesseeessee 17 3 3 3 Header Reset Button eese nnns 17 3 4 Computer Requirements seirinin nennen nnn nnns 18 3 4 1 Recommended Hequirement eese 18 3 4 2 Minimum Requirement ccccccccccceecceecnsesccusccesensuscsusecseenenssees 18 3 5 Installation of Acquisition and Diagnostic Software Option 18 3 6 Connect the Cable and Power Cord sss 18 3 6 1 Connect Interface Cable cccccccccsecccsesccsnscsc
16. ch on both D sides at least CU Back Side uU Free space of 20 cm 8 inch on back side at least to allow the power switch power cord and USB cord to be reached by hand at all times DANGER Only authorized or trained personnel should set wall mount installation NOTE Refer to Wall Mount Installation Guide provided with Wall Mount Installation Kit User Manual FireCR Flash TM 401 EN DANGER Install the wall mount on a solid wall perpendicular to the floor When attaching to other building materials please contact your local dealer If installed on a slanted wall it may fall and result in severe injury DANGER 3D Imaging amp Simulations Corp is not liable for product damage or personal injury when the user fails to follow the product installation instruction WARNING Pulling pushing or climbing on the system may cause the system fall 3 3 Identify Important Features Look over the reader and features shown in this section User will need to know where these features are when user operates the reader in later chapters 3 3 1 Header Connecting Part WR K USB 2 0 Port Ethernet Port Power Inlet Power Switch User Manual FireCR Flash TM 401 EN 3 3 2 Header Status Indication LED Indication LED shows the status of the reader as described below fon SmemOn Cassette is in initial position and On Ready to Scan P ready to scan Bg Smwm Blinki
17. ch on front side at least for cassette insertion and ejection 4 Front Side Free space of 20 cm 8 inch on backside at least to allow the power switch power cord and USB cord to be reached Fi rec R flash by hand at all times Backside User Manual FireCR Flash TM 401 EN DANGER Never place the reader on the floor Sliding the reader may result in internal damage or misalignment of the optics Install in a location that is level and stable Installation in an unsuitable location can cause accident or deterioration in image quality WARNING Sliding the reader may result in internal damage or misalignment of the optics External vibration or shock during scanning may affect image quality The scanner must be placed on rigid flat and reinforced desk or tabletop DANGER Do not place anything on top of the scanner WARNING This equipment may be interfered or interfere by electromagnetic or other interference Assure a distance of minimum 1 0 m with neighboring equipment 3 2 Wall Mount Option The FireCR Flash can be mounted on the wall to save space occupancy When purchasing the wall mount kit a detailed installation guide and all parts necessary for assembly are provided User Manual FireCR Flash TM 401 EN Free space of 50 cm 20 inch on top side at least for cassette insertion and ejection Front Side Free space of 10 cm m 4 in
18. cording to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as deter mined by an electromagnetic site survey a Should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol C Note 3 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people User Manual FireCR Flash TM 401 EN a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the EUT is used exceeds the applicable RF compliance level above the EUT should be observed to verifynormal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the EUT b Over the frequency range 150 kHz to 80 MHz field strengths should be less than V1 V m Hecommended Separation Distances Between Portable and Mobile RF Communications Equipment and the FireCR Flash system The FireCR Flash system
19. ctices Affordable rugged compact lightweight fast and effective FireCR Flash System enables all imaging functions to be performed with the advanced image management software a solution that can be adapted most clinical applications The FireCR Flash Computed Radiography solution with enhanced workflow and improved productivity are the best solution for medium sized healthcare facilities and clinics The FireCR Flash System complements centralized CR and DR environments such as clinics ER and OR departments User Manual FireCR Flash TM 401 EN Main Features State of the Art Scanning Mechanism FireCR Flash adopts state of the art scanning mechanisms using high beam delivery efficiency optics module to construct its compact and rigid structure High Throughput Its unique and patented dual direction scanning mechanism enables to improve the efficiency and high throughput Scanning Resolution User selectable resolution of 100um and 200um allows user to make diagnosis on variable purposes Detector High sensitive photomultiplier tube equipped in FireCR Flash delivers high gain wide dynamic range and high speed response for radiographic imaging Powerful Acquisition and Diagnostic Software Acquisition and Diagnostic Software designed for the FireCR Flash and its accurate and rapid data processing make the reader more powerful User Manual FireCR Flash TM 401 EN Chapter 2 Unpacking 2 1 Inspection for Damage FireCR F
20. h TM 401 EN 4 3 5 Circuit Functions 5 RFID Board 3 Driver Board 2 Main Board 14 1 Align Motor L 1 i i 1 ii ii Step M 24V p Motor 1 i 24V Driver i Step Motor LLS15V i o4 it 1 H bog ET E 1 1 H 1 i Analog rv CM 1 1 Pg f 1 H 1 LI 1 1 le J 1 6 Peripheral FPGA MCU i 1 1 1 i i I Clock I Clock gumemm Ld ge 168MHz 1 i Hz 1 1 f uv i i d Ethernet 10 100Mbps 6 Peripheral aH gt Transceiver 1 i H H i i od i 1 3 T i i m ransceiver i i Regulator Regulator Regulator 18V E g g g i i 3 3V 2 5V i R LI i i i AC Inlet amp SMPS DC DC EMI 24V 2 5A Converter EMI Filter j 15V0 25A Filter gt i 25V 0 25A 5V 3 5A Figure 11 Circuit diagram v Power Board Power board generated DC Power of 15V 15V 5V v Main Board This parts controls peripherals for image acquisition And it delivers amplified digitized signal to PC via USB or Ethernet v Driver Board This parts controls peripherals for PSD peak detect Eraser control high voltage generation v BLDC Board This parts controls BLDC Motor and square mirror spin Y RFID Board This part communicates with the RFID tag RFID tag is contain IP Cassette information Y Peripheral This is peripherals for image acquisition It consists of Eraser which erases residual images in imaging plate Step Motor and Interrupters which moves
21. lash is shipped in a custom designed container to protect the reader from external shock Before unpacking the reader inspect the shipping container for damage In case the container is damaged notify the shipper immediately 2 2 Identify the Components Identify each of these components CR FP 41 001 FireCR Flash CR Reader CR FP 42 001 Cassette including IP 35cm x 43cm CR FP 42 002 Cassette including IP 24cm x 30cm CR FPA 02 001 USB 2 0 Interface Cable CR FPM 44 001 FireCR Flash User Manual Optional items CR FP 42 003 Cassette including IP 18cm x 24cm CR FP 46 001 Wall Mounting Kit for FireCR Flash FP 05 001 FireKit Field Upgrade Kit CR WARNING If the FireCR Flash needs to be returned to manufacturer or one of its representatives the scanner must be repacked in the original container with all accessories User Manual FireCR Flash TM 401 EN WARNING Use of Power Cord Type SJT or SVT min 18AWG 3 Conductor VW 1 125V min 10A or 250V 10A Max 3 0m long One end with Hospital Grade Type NEMA 5 15P for 125V or NEMA 6 15P for 250V Other end with appliance coupler CAUTION Grounding reliability can only be achieved when the equipment is connected to an equipment receptacle marked Hospital Only or Hospital Grade For connection to supply not in USA make sure the power cord is the correct type that is required in your area WARNING Improper disposal of this product may result
22. nd those directly connected to wa b the public low voltage power supply network that Voltage fluctuation Complies supplies buildings used for domestic purposes recowmoas fo User Manual FireCR Flash TM 401 EN 5 2 Manufacturer s Declaration Electromagnetic Immunity The FireCR Flash system is intended for use in the electromagnetic environment specified below The customer or the user of FireCR Flash system should assure that it is used in such an environment Immunity test Compliance level Test level Environment guidance Electrostatic 6 kV Contact 6 kV Contact Floors should be wood discharge ESD 8 kV Air 8 kV Air concrete or ceramic tile If IEC 61000 4 2 floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast 2kV for power supply lines 2kV for power supply lines Mains power quality should be Transient burst 1kV for input output lines 1KV for input output lines that of a typical commercial or IEC 61000 4 4 hospital environment Surge 1 kV differential mode 1 kV differential mode Mains power quality should be IEC 61000 4 5 2 kV common mode 2 kV common mode that of a typical commercial or hospital environment Power frequency Power frequency magnetic 50 60Hz fields should be at levels Magnetic field characteristic of a typical IEC 61000 4 8 location in a typical commercial or hospital environment Voltage dips short 596 Ur gt 95 dip in Ur 596 Ur
23. ng Emm Blinking Big Emr 3 3 83 Header Reset Button In case that the reader is stuck during scanning push reader reset button by sharp pin to initialize the reader Header Reset Button WARNING Do not push scanner reset button during scanning User Manual FireCR Flash TM 401 EN 3 4 Computer Requirements 3 4 1 Recommended Requirement Operating System Microsoft Windows 7 8 intel CORE i RAM 4 GB or more Hard Disk 500 GB Free Hard Disk Space T Gbps Etherne 32bit Color Displey Video Resolution 1920 x 1080 1440 x 900 3 4 2 Minimum Requirement Operating System Microsoft Windows 7 intel Processor RAM 2 GB or more Hard Disk 80 GB Free Hard Disk Space Gbps Ethernet 32 bit Color Display Video Resolution 1366 x 768 1280 x 800 1600 x 900 1280 x 1024 3 5 Installation of Acquisition and Diagnostic Software Option Refer to Acquisition and Diagnostic Software manual 3 6 Connect the Cable and Power Cord 3 6 1 Connect Interface Cable The reader interfaces with computer via USB2 0 cable or Ethernet cable RJ45 CAT 5E FTP 1 Use the USB Ethernet cable in the shipping container 2 Connect the cable to the reader s USB2 0 Ethernet port located on the rear of the reader 3 Connect the other end of the cable to the USB2 0 Ethernet port on the computer User Manual FireCR Flash TM 401 EN DANGER This equipment is indoor use only and all the comm
24. nscscnsessnsessnsesseeees 18 9 0 7 CONNEC Ihe JOWOF COMO acsxeccseippes tiet EYE EE IRE RK Indore 19 3 6 3 Installation Report esses seen 20 Chapter 4 Operating cccccccceeccceeccnscssneccsessnseeeeessesensnesstsesseesseeses 21 4 1 System Specifications eese esesesei ese arae a nana nane raa 21 4 2 Operation Condltions seeeesssessseeee essen 22 4 83 Operating Instructions sees seen nennen nnn nnns 23 ASA TUMON TIC Road l sascecicestsanteancsncccacives tine deandsasinanivacdinndeascincces 23 dos FONT OM TAS COMO OC aot anc uU ERE eine tence eee 23 4 3 3 Cassette Insert and Eject cccccccccsecccsseeecsnececsesesseeessseesseeees 23 4 3 4 Getting a Scanned Image esses eene 23 JOD COCUT UCO snae E eee UMEN EI UE 24 User Manual FireCR Flash FNi 401 EN Chapter 5 Symbols cccccccccceccccsscccsecccsusccsnsesseeessseeessesessesessnsesanes 25 5 1 Manufacturer s Declaration Electromagnetic Emission 26 5 2 Manufacturer s Declaration Electromagnetic Immunity 27 5 3 Guidance and Manufacturer s Declaration Electromagnetic DU Y e eE E N IA NEEN E ENE E EE EON 30 5 4 Laser Safety Statement ccccccccccccsecccsseeccsneeeeseeceseeeeseeessneeesanes 31 Chapter 6 Warranty and Repair Service ccccccceeceeccnsecnseenseenees 32 6 1 Standard Warranty
25. ntact 3D Imaging amp Simulations Corp or authorized dealer Do not spill liquids on the device and never operate the device in a wet environment Keep the device from radiators and heat sources Use the device only with accessories supplied with this device This device is intended to be grounded Plug power cord into properly grounded electrical outlets This cord is equipped with three prong plugs to help ensure proper grounding This device contains static sensitive components Proper static handling procedures and equipment must be used when servicing this device User Manual FireCR Flash TM 401 EN Do not look inside of the device If any of the following conditions occur unplug the device from the electrical outlet and contact authorized service personnel The power cord or power adapter is damaged An object has fallen into the device The device has been exposed to water The device has been dropped or damaged The device does not operate correctly when the operating instructions are followed Intended Use This device is a Computed Radiography System and intended for use in producing digital X Ray images for general radiography purposes It comprises of reader cassette with reusable imaging plate and workstation software It scans X Ray exposed image plate and produces X Ray image in digital form Then digital image is transferred to workstation for further processing and routing This device is intended to
26. ntenance parts and technical support for its non consumable hardware products five years after a product is discontinued Technical support for old versions of software products will cease 12 months after they are upgraded or discontinued 6 3 Out of Warranty Repair Service Out of warranty repair service is available in selected geographical locations Contact the supplier for current terms and rates User Manual FireCR Flash TM 401 EN 6 4 Shipping The FireCR Flash is a solidly built system designed to survive shipping around the world However in order to avoid damage during shipping the FireCR Flash must be properly packaged In general the best way to package the FireCR Flash is in the original factory container f this is no longer available we recommend that user carefully wraps the FireCR Flash in at least 75 mm 3 inch of foam or bubble pack sheeting The wrapped device should then be placed ina sturdy cardboard carton Mark the outside of the box with word FRAGILE and an arrow showing which way is up We do not recommend using loose foam pellets to protect the FireCR Flash f the carton is dropped by the shipper there is a good chance that the device will shift within the loose pellet packing and be damaged If user needs to ship the FireCR Flash to another location or back to the factory and user does not have a means to adequately package it user can order additional shipping container This may seem an expense
27. ow but which do not affect the functionality of the system User Manual FireCR Flash TM 401 EN General Safety Guidelines All the safety and operating instructions should be read carefully before this device is operated This device has been designed and tested to meet strict safety requirements applicable to medical equipment and has been supplied in a safe condition To ensure personnel and patient safety the device shall be operated and serviced in compliance with all procedures warnings and precautions during all phases of operation and service of this device Failure to comply to with safety guidelines may result in injury to service personnel operator or patient 3D Imaging amp Simulations Corp assumes no liability for failure to comply If this device is not used as specified the protection provided by the device could be impaired This device must be used in a normal condition only Installation service and operation of this device should only be undertaken by qualified trained personnel The operator should study instructions and precautions carefully before starting to use the device listed here and throughout the manual There are no user serviceable parts inside this device The device should only be opened and serviced by qualified service personnel Failure to heed this warning may result in injury to service personnel or damage to equipment and void any and all warranties If there is a service problem please co
28. unication wirings are limited to inside of the building WARNING Do not pull out the USB Ethernet cable during scanning 3 6 2 Connect the Power Cord 1 Connect the power cord to the reader located on the rear side 2 Connect the other end of the cord to a grounded power outlet DANGER This equipment must only be connected to supply mains with protective earth Use only a three wire cord that has grounding This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug DANGER Do not use any power cord other than the power cord included with the system Doing so may lead to fire electrical shock or electrocution WARNING Socket outlet shall be installed near the device and shall be easily accessible Do not place the device where difficult to access to appliance inlet Do not unplug the power cord or turn the power switch off during scanning User Manual FireCR Flash TM 401 EN 3 6 3 Installation Report After installation of the reader fill in Installation Report from Appendix I and send to 3D Imaging amp Simulations Corp service department by fax or e mail m Fax 82 42 931 2299 E mail support 3DISCimaging com User Manual FireCR Flash TM 401 EN Chapter 4 Operating 4 1 System Specifications ing Pixel Pi Standard Sampling Pixel Pitch Standard 1750