Operating Manual for Digital-pH

image

Contents

1. We also recommend to keep a certain amount of 3 mol l KCI on stock for re filling General maintenance and measuring instructions for pH combi electrodes our standard type GE 014 This pH electrode has been subjected to a series of tests demanding maximum quality standards in all stages of manufacture Attached electrode can be used for 2 to 12 pH respectively at temperatures between 5 and 45 C and conductivity gt 200 pS cm 1 Make sure to observe the following points to maintain optimum capacity and accuracy of electrode as long as possible 1 1 Remove storage protection cap from pH glass diaphragm and rinse glass body and pH glass diaphragm with ordinary tap water Then dry glass body and pH diaphragm with soft tissue 1 2 Important Make sure to always keep pH glass diaphragm in a slightly moist condition If electrode is not used the pH glass diaphragm has to be immersed into a 3 mol l KCI solution for storage Drying out of the pH glass diaphragm will affect both its capacity and sensitivity In order to wet it throughout put glass diaphragm in a 3 mol l KCI solution for 24 hours 1 3 Please avoid touching of the glass diaphragm as even the slightest damage to or abrasion of its surface may negatively affect the capacity of the electrode 1 4 Make it a rule to always visually check pH electrodes for any air bubbles that might be enclosed in the pH glass diaphragm and the external reference electrode cell In case of air bubble
2. value to 4 00 H24 0 01 6C 08 page 3 of 4 In order to check calibration repeat procedures for calibration points 1 and 2 using corresponding turning knob for re adjustments In case you did not prepare pH 4 0 but another buffer solution eg pH 10 0 or pH 12 0 the corresponding value pH 10 0 or pH 12 0 can be set calibration of second calibration point using the left hand turning knob pH X Please note that for each and every calibration procedure the buffer solution value pH 7 0 ie 7 00 has to be set by means of the right hand turning knob ph 7 Note We recommend to re calibrate the measuring device prior to each new measuring series to ensure optimum accuracy It has to be considered that the calibration solution and the media to be measured should had similar temperatures After completion of measurements fill electrode protection cap with 3 mol l KCI solution and slip it back onto electrode Gentle squeezing of the cap displaces air thus allowing cap to be slipped on easily Attention pH electrodes are extremely delicate and sensitive measuring elements Prior to using the pH electrode please carefully read corresponding maintenance and measuring manual We shall not assume any warranty if customer failes to use proper care and skill eg breaking of electrode drying out blocking etc Points to be observed during measuring As resistance values resulting from both the pH electrode and from the measuring device are g
3. Legislation for the member countries regarding electromagnetic compatibility 2004 108 EG additional errorr lt 1 Point s to be observed during operation a In case of low battery voltage BAT is displayed make sure to exchange battery immediately as too low an operation voltage may lead to incorrect measuring results We recommend to take out battery if device will not be operated for some time or storaged over 50 C Please note Ifthe battery voltage falls even lower the voltage may not be sufficient for BAT to be displayed so that there will be no BAT indication although the battery has been used up We recommend to make it a rule to always check the battery if the values indicated seem to be completely out of range b Makesuretomaintain device an electrode properly and to operate it in accordance with the specification listed do not throw knock etc c The electrode must be stored in 3 mol l KCI ours type KCI3M in order to avoid drying out excluded GE103 d Before measuring the protection cap has to be removed e Our pH electrodes can be used in a degree range from 90 to 45 compared to horizontal Disposal instruction The device and electrode must not be disposed in the unsorted municipal waste Send the device directly to us sufficiently stamped if it should be disposed We will dispose the device appropriate and environmentally sound WEEE Req Nr DE93889386 PCE Instruments UK Ltd
4. Standard pH electrode with 3 mol l KCI Our types GE 100 or GE 014 5 Soil examinations Glass electrode with several diaphragms Our type GE 101 Use prick lance first H24 0 01 6C 08 page 4 of 4 6 Cheese fruit meat Insertion electrode Our type GE 101 When conducting measurements in cheese milk and other products containing proteins a special cleaning agent has to be used for cleaning of the electrode pepsin solution can be ordered from us Normal cleaning 0 1 molar HCI solution for at least 5 min or protein cleaning agent Generally speaking the service life of electrodes is 8 to 10 months with proper care and maintenance their service life may even be extended to over 2 years The actual service life is however dependant on the individual application If you can no longer set the pHX value this could either be an indication that a the electrode is worn out and needs to be replaced or that b the buffer solution is used up prepare new solution Even if treated very carefully during calibration to avoid carrying over of buffer solution residuals from one solution to another if electrode is not sufficiently cleaned and dried buffer solutions only keep for a certain period of time approx 1 month Buffer capsules can be kept for an unlimited period of time we therefore recommend to keep a certain number on stock PH12 buffer capsules white have to be stored in an exsiccator or stored together with drying agent
5. Units 12 13 Southpoint Business Park Ensign Way Southampton United Kingdom S031 4RF Phone 44 0 2380 98703 0 Web Fax 44 0 2380 98703 9 http www industrial needs com email info industrial needs com http www pce instruments com H24 0 01 6C 08 page 2 of 4 AN Safety Requirements This device has been designed and tested in accordance with the safety regulations for electronic devices However its trouble free operation an reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device 1 Trouble free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under Specification 2 Ifthe device is transported from a cold to a warm environment condensation may cause in a failure of the function In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start up 3 Ifthere is a risk whatsoever involved in running it the device has to be switched off immediately and to be marked accordingly to avoid re starting Operator safety may be a risk if there is visible damage to the device the device is not working as specified the device has been stored under unsuitable conditions for a longer time In case of doubt please return device to manufacturer for repair or maintenance 4 Attention Do NOT us
6. cleaning agents or solvents Biological coatings containing proteins 1 pepsin enzyme in 0 1 molar HCI solution Resin lignines Acetones Highly resistant deposits Hydrogen superoxide sodium hypochloride The distinct materials of the electrode have to be considered when choosing the cleaning agent E g electrodes with plastics shaft must not be cleaned with solvents In case of doubt please contact the manufacturer for further advice The same has to be considered when using aggressive or other non water based agents
7. H24 0 01 6C 08 page 1 of 4 Operating Manual for Digital pH Meter S pecification Measuring range Resolution Accuracy device only pH electrode Input resistance Display Working temperature Relative humidity Power supply Battery service life Low battery warning Dimensions Weight Calibrating EMC GPH 014 0 00 to 14 00 pH 0 01 pH 0 02 pH 1 digit at nominal temperature 25 C pH electrode GE014 standard electrode incl in scope of supply plug in via front side electrode socket Cinch GE014 combined measuring and reference electrode with refillable 3 mol KCl electrolyte measuring range 2 to 12 pH temperature 5 to 45 C conductivity gt 200 uS cm For permanent measurements in a highly alkaline environment special electrodes have to be used Please refer to special accessories approx 10 Ohm approx 13 mm high 3 digit LCD 0 to 45 C 0 to 80 Fr F non condensing 9V battery Type IEC 6F22 included in scope of supply approx 200 h Automatic BAT displayed in case of low battery voltage approx 106 x 67 x 30 mm H x W x D approx 200g incl battery and electrode GE014 3 turning knobs for 1 temperature compensation 0 to 90 C 2 pH 7 value 3 pH X value e g pH 1 09 pH 4 pH 10 or pH 12 depending on working environment The device corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of
8. e this product as safety or emergency stopping device or in any other application where failure of the product could result in personal injury or material damage Failure to comply with these instructions could result in death or serious injury and material damage 5 The electrodes contain 3 molar KCL GE103 1mol l KNO3 which is acidly First Aid provisions After contact with skin clean with sufficient water After contact with eyes rinse opened eye with sufficient water contact oculist After swallowing drink much water When feeling sick contact doctor Calibrating of ph Meter Accessories required calibrating solution for ph7 and ph4 respectively special accessories ph10 ph12 How to prepare a calibrating solution fill 2 plastic bottles Special accessories with 100 ml distilled water eg battery water each 100 ml will cover the entire cylindrical area ie approx 55 mm as of bottle base open ph7 capsule green carefully turn one half of the capsule while pulling and make sure not to spill any solution put content including both capsule parts into one of the bottles place second capsule for ph4 orange respectively ph10 or ph12 including both capsule parts in second bottle The capsule will imbue the liquid with the respective characteristic colour orange ph 4 0 green ph 7 0 blue ph 10 0 colourless white capsule ph 12 0 Make sure to prepare buffer solutions in time as they can only be used after 3
9. enerally very high when conducting pH measurements the electrode should not be hand held but put down during the measuring operation in order to avoid a shift in voltage parameters between the electrode and the measuring device In case there is no suitable place where to position the device during measuring we recommend that the device is held as far away from the plut as posible and that there is as little movement as possible Holding the electrode in one hand and the device in the other could also help to minimise a shift in voltage parameters Make it a rule never to touch the device near the sensor plug as your hand may cause autocapacitance coupling resulting in measuring inaccuracies Sudden jumps and changes in the values given on the display when touching or shaking the plug are not normally due to a loose contact in the plug but result from capacitance changes caused by interference from hand contact The pH electrode All electrodes are delivered checked and ready for measuring The warranty period is 6 months for appropriate treating Introduction pH electrodes are wearing parts which depending on the chemic and mechanic stress they are subjected to have to be replaced as soon as the values required can no longer be maintained even after a most thorough cleaning and regeneration Please take into account that various substances in hydrous solutions may attack glass and that certain chemic substances and the KCI solution in the elect
10. hours Shake well before use Calibration of pH meter In order to ensure optimum measuring accuracy the calibration range should be larger than the measuring range We recommend using the following calibration solutions for measurements less than pH 7 pH4 0 and pH 7 0 more than pH 7 pH 7 0 and pH 12 0 Plug in Cinch plug of pH electrode into corresponding socket and switch on device by means of the lateral slide switch a number with decimal point will be displayed on the LCD Determine temperature of buffer solution and set accordingly using the central turning knob controller for temperature compensation 0 to 90 C 1 graduation mark approx 10 C Place GPH014 meter on a solid surface if possible try to avoid holding the meter in your hand during calibration please refer to Points to be observed during measuring Setting of the first calibration point Carefully remove protection cap from electrode Attention cap contains 3 mol l KCl Rinse electrode with distilled water dry electrode place it in buffer solution pH 7 0 Wait for approx 20 to 30 seconds for display to show stable value then use turning knob at the far right side pH 7 to set value to 7 00 Setting of the second calibration point Rinse electrode with distilled water once again dry electrode place it in buffer solution pH 4 0 Wait for another 20 to 30 seconds for display to show stable value then use turning knob at the far left side pH X to set
11. rode may cause a chemic reaction leading to the blocking up of the diaphragm Examples When coming into contact with solutions containing proteins as may be the case when conducting measurements in the medical and biological field KCI can cause denaturation of the protein Coagulated lacquers Solutions containing a larger concentration of silver ions Problems may also occur when conducting measurements in low ion media containing solvent Some of the problems occurring in such media can be prevented by using a double chamber electrode with suitable jumpering electrolyte type depending on application Our type GE 103 As they will influence the measurements any deposits that may accumulate on the measuring membrane or diaphragm have to be removed regularly eg by means of an automatic cleaning device Special electrodes for various applications 1 Measurements in low ion media rain water water in aquariums de mineralised water Our type GE 104 special faceted electrode for gt 50uS cm or GE 106 gt 100uS cm 2 Seawater aquariums Standard combined measuring and reference electrodes with 3 mol l KCI Our types GE 100 or GE 014 3 Photographic laboratories Use double chamber electrode with jumpering electrolyte 1 molar potassium nitrate solution potassium nitrate solution has to be replaced as and when required Fill watering cap with potassium nitrate solution for storage of electrode Our type GE 103 4 Swimming pools
12. s being apparent these can be removed by shaking the electrode downwards as for a clinical mercury thermometer 1 5 In order to avoid a pressure build up or vacuum in the reference electrode cell thus ensuring trouble free penetration shift rubber closing collar covering the electrolyte filling hole For storage the closing collar has to be properly and carefully replaced as otherwise the electrolyte will leak During measurements the lateral diaphragm should also come into contact with the material to be measured Minimum immersion depth for GE 014 is 20 mm max 50 mm 1 6 Electrode cable and plug should always be clean and dry as otherwise the electrical insulation may be damaged this resulting in incorrect measurements as well as other faults 2 Care and maintenance 2 1 Check liquid level of reference electrolyte at regular intervals if necessary top up with 3 mol l KCI solution through filling hole using a syringe or pipette 2 2 Crystaization of the 3 mol l KCI is not avoidable Crystalized KCI at protection cap or closing collar can easily be removed by fingernail or cloth and is no defect or reason for reclamation 2 3 Dirty electrodes have to be cleaned You will find suitable cleaning agents for the pH glass diaphragm in the following table Contamination Cleaning agent Various deposits Light cleaning agent Inorganic coatings Commercial liquids for cleaning of glass Metal compounds 1 mol l HCI solution Oil grease Special