1. www apc com Connect Battery Back UPS ES 650 User s Guide For safety the Back UPS ES is shipped with one battery wire disconnected The UPS will not operate until the wire is connected to the touch safe battery terminal NOTE Small sparks may occur dur Turn the Back UPS ES over and press in the release tab Slide the plastic battery cover off of the Back UPS Connect Equipment Battery Backup z Surge Protectio These outlets are powered whenever the Back UPS ES is switched ON During a power outage or other utility problems brownouts over voltages these outlets will be powered for a limited time by the Back UPS ES Plug your computer monitor CD ROM drive or other data sensitive devices such as an external disk or tape drive or Home Phoneline Networking Association HPNA device into these outlets ing battery connection This is normal Insert the battery back into the compartment Slide the plastic battery cover until the release tab locks into place Connect the black battery wire firmly to the negative battery terminal Place the Back UPS ES to avoid d Direct sunlight Excessive heat Excessive humidity or contact with fluids lt Plug the Back UPS ES power cord directly into a wall outlet not a surge protector or power strip n Connect Computer Cable The supplied cable and software provide automatic file saving and shutdown of the
2. the unit ON A single short beep and the green Power On indicator confirms the Back UPS ES is on and ready to provide protection The Back UPS ES should charge for at least 16 hours to ensure sufficient runtime The unit is being charged whenever it is connected to utility power whether the unit is turned ON or OFF If the red Building Wiring Fault indicator located on the end near the power cord is lit your building wiring presents a shock hazard that should be corrected by a qualified electrician Install the PowerChute Personal Edition software Place the PowerChute Personal Edition CD ROM into your computer and follow the installation instructions on the screen 990 1989 Copyright 2005 American Power Conversion Corp FAULT INDICATOR MODEM CATV CONVERTER or DSS INPUT FROM WALL JACK DATALINE OUTPUT TO DSL MODEM PHONE or NETWORK 10 1 00BASE T CABLE INPUT FROM INTERNET SERVICE PROVIDER ISP CATV or DSS chine TO COMPUTER SB PORT CIRCUIT BREAKER PUSH TO RESET Status Indicators The Back UPS ES indicates operating status using a combination of visual and audible indicators Use the following table to identify the status of the Back UPS ES Status Visual Indications Power On Green Replace Battery Red Audible Indication Alarm Terminates When Power On UPS is supplying conditioned utility power to the load Power On LED ON None Not
3. 18 0 cm APC Technical Support about obtaining a new set Pack the unit properly to avoid Operating Temperature 32 F to 104 F 0 C to 40 C damage in transit Never use foam beads for packaging Damage sustained in transit is not covered under warranty insuring the package for full value is recommended Storage Temperature o OF _450 o air 5 F to 113 F 15 C to 45 C 6 Write the RMA on the outside of the package Operating Relative Humidity 0 to 95 non condensing 7 Return the unit by insured carrier to the address given to you by APC Technical Operating Elevation 0 to 10 000 ft 0 to 3 000m Support Safety and Safety Approvals UL 1778 listed CUL certified per a Regulatory CSA standard C22 2 No 107 1 NOM 001 APC Contact Information Online Technical Support http support apc com http www apc com support esupport apcc com Wall Mounting Template Gabarit de fixation murale Plantilla para montaje en la pared cause undesired operation Web Site www apc com On the bottom of this equipment is a label that contains USA Canada 1 800 800 4272 among other information the FCC registration number Mexico 52 292 0253 552 292 0255 and ringer equivalence number REN for this equipment Brazil 0800 12 72 1 If requested this information must be provided to the see telephone company Worldwide 1 401 789 5735 y 6 0 152 mm y
4. about 2 minutes of power remaining Immediately power down your computer and turn the unit OFF When normal power returns the unit will recharge the battery Call a qualified electrician for service Allow the unit to charge by leaving it plugged into the wall at least 16 hours As a battery ages the amount of runtime available will decrease You can replace the battery by ordering one at www apc com Batteries also age prematurely if the Back UPS ES is placed near excessive heat Make sure the data line from the wall outlet is connected to the jack labeled Wall Outlet Phone Fax DSL or Cable In Cable DSS CATV Plug the AC power cord of the modem into one of the four Battery Backup Surge Protection outlets Order Replacement Battery Replace with an APC qualified battery Replacement batteries can be ordered from www apc com valid credit card required The replacement battery part number for this Back UPS is RBC17 Input Voltage 120 Vrms Nominal Frequency 50 60 Hz auto sensing Brownout Transfer 88 Vrms typical Wa rra nty Over voltage Transfer 139 Vrms typical The standard warranty is 3 years from the date of purchase APC s standard Output UPS Capacity 4 outlets 650 VA 390 W procedure is to replace the original unit with a factory reconditioned unit Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact w
5. applicable On Battery UPS is supplying battery power to the load connected to the Battery outlets Power On LED ON off during beep Beeping 4 times every 30 seconds UPS transfers back to Power On operation or when UPS is turned off Low Battery Warning UPS is supplying battery power to the load connected to the Battery outlets and the battery is near exhaustion Power On LED flashing Rapid beeping every 1 2 second UPS transfers back to normal operation or when UPS is turned off Replace Battery The battery is disconnected The battery is in need of charging or is at the end of its usual life and must be replaced Replace Battery LED flashing Power On and Replace Battery LEDs Flashing alternating Constant tone Constant tone UPS turned off with the power switch the battery power has been completely exhausted and the UPS is waiting for utility power to return to normal seconds Overload Shutdown During On Battery None Constant tone UPS turned off with the operation a battery power supplied outlet power switch overload was detected Sleep Mode During On Battery operation None Beeping once every 4 Utility power is restored or if utility power is not restored within 32 seconds or the UPS is turned off Building Wiring Fault Your building wiring presents a shock hazard that should be corrected by a licensed electrician Building W
6. ck UPS ES has exhausted its available battery power Connected equipment does not accept the step approximated sine waveform the Back UPS ES The Back UPS ES may require service The Back UPS ES is using battery Battery capacity is low about 2 minutes of use remaining Your building wiring presents a shock hazard Using the Back UPS with this condition will void the warranty The battery is not fully charged Battery is near the end of useful life Data line from the ISP or wall outlet is connected to the wrong jack on the Back UPS Modem has lost AC Power Total Amperage 8 outlets Voltage On Battery 12 Amps including UPS output 115 Vrms 8 step approximated sine wave Frequency On Battery 50 60 Hz 1 Hz Transfer Time 6 ms typical 10 ms maximum Protection and Filter AC Surge Protection Full time 375 joules Phone fax DSL Surge Protection Single line 2 wire Cable CATV DSS Surge Protection One Coax Input Output Network Surge Protection 10 100Base T Ethernet EMC Compliance Notice This device complies with part 68 and part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may Connect the battery see Connect Battery and e
7. iring Fault LED red ON None UPS is unplugged or is plugged into a properly wired outlet See the Troubleshooting section for additional assistance APC Back UPS and PowerChute are registered trademarks of American Power Conversion Corp All other trademarks are property of their respective owners Use the table below to solve minor Back UPS ES installation or operation problems Consult APC Online Technical Support or call APC Technical Support for assistance with problems that cannot be resolved using the table below Troubleshooting Back UPS ES will not turn on No power available at the Surge Protection Only outlets Connected equipment loses power The Power On indicator is lit and the Back UPS ES is beeping four times every 30 seconds The Power On indicator flashes and the Back UPS beeps twice per second at the same time Building Wiring Fault indicator is lit Inadequate runtime No phone fax DSL cable or network signal from the Back UPS Internet connection is lost during power outage Specifications Battery is disconnected or utility power is not available at the wall outlet Surge Protection Only outlets have been overloaded Utility power not available at the wall outlet Equipment is connected to the Surge Protection Only outlets The Back UPS ES is overloaded PowerChute Personal Edition software has performed a shutdown due to a power failure The Ba
8. ith APC Technical Support APC will ship the replacement unit once the defective unit is received by the repair department or cross ship upon the provision of a valid credit card number The customer pays for shipping to APC and APC pays ground freight transportation costs back to the customer Service Please DO NOT RETURN Back UPS ES to the place of purchase under any circumstances 1 Consult the Troubleshooting section to eliminate common problems 2 Verify the battery is connected see Connect Battery and that the Circuit Breaker is not tripped see Troubleshooting section EMI RFI Filter Full time If you still have problems or questions please contact APC via the internet or at one of AC Input Resettable circuit breaker the phone numbers Iisted below 3 Before contacting APC please be sure to record the date purchased UPS model Battery Type Sealed maintenance free lead acid and serial number on bottom of unit Average Life 3 5 years depending on the number of discharge cycles 4 Be prepared to troubleshoot the problem over the telephone with a Technical and environmental temperature i BN ae Support Representative If this is not successful the representative will issue a Return Physical Net Weight 16 Ibs 7 kg Material Authorization Number RMA and a shipping address Dimensions H x W x D 3 8 x 10 9 x 7 1 5 Pack the unit in its original packaging If the original packaging is not available ask 9 6 x 27 7 x
9. nsure power is available at the wall outlet Reduce the amount of equipment plugged into Surge Protection Only outlets Ensure the fuse or circuit breaker for the outlet is not tripped and that the wall switch controlling the outlet if any is in the ON position Ensure the equipment you want to stay powered during a power failure is plugged into the Battery Backup Surge Protection outlets and NOT the Surge Protection Only outlets Make sure the equipment plugged into the outlets of the unit are not overloading its capacity Try removing some of the equipment and see if the problem continues The Back UPS ES is operating normally The Back UPS ES can only operate on battery power for a limited amount of time The unit will eventually turn off when the available battery power has been used Allow the unit to recharge for 16 hours before expecting maximum runtime The output waveform is designed for computers and computer related equipment It is not designed for use with motor type equipment Contact APC Technical Support for further troubleshooting The Back UPS ES is operating normally and using battery power Once On Battery you should save your current work power down your equipment and turn the unit OFF Once normal power is restored you may turn the unit back ON and power your equipment The Back UPS ES is about to shut off due to a low battery charge condition When the unit beeps twice every second the battery has
10. operating system in the case of a sustained power outage Connect the cable to the Data Port of the Back UPS ES Connect the other end of the cable to the USB port on your computer The software will automatically find the USB Port of your computer a J L 4 Battery Backup 4 Surge Protection r Surge Protection Only POWER ON metas REPLACE BATTERY _ i INDICATOR jjj O Dogon g 17 Oo s 0 Arc oooo0g0 oo Connect Modem Phone DSL Fax 10 100Base T HPNA Cable Modem CATV or DSS to Surge Protection The Back UPS protects a single line 2 wire phone including Digital Subscriber Line DSL Home Phoneline Networking Association HPNA type equipment modem 10 100 Base T Ethernet or fax machines from surges when connected through the UPS as shown in the drawing below The UPS also protects a cable modem CATV converter or DSS receiver from surges when it is connected through the UPS coaxial connectors as shown in the drawing below BUILDING WIRING CABLE OUTPUT TO ae f Surge Protection Only These outlets provide full time protection from surges even if the Back UPS ES is switched OFF Plug your printer fax ma scanner or other peripherals that do not need battery power into U these outlets Power On and Install Software Press the ON OFF switch to power