Home
Please click here to User Manual in PDF
Contents
1. To avoid the possibility of an explosion or fire do not store or use combustible flammable or explosive vapors and liquids such as gasoline inside or in the vicinity of this or any other appliance Keep all combustible items such as aerosol cans away from cook top burners ovens and range hoods Do not store flammable or explosive materials in adjacent cabinets or surrounding areas Disclaimer manufacturer and or distributor reseller decline all responsibility in the event of failure to observe the instructions provided for installation maintenance and suitable use of the product The manufacturer and or distributor reseller shall NOT be responsible for any injury due to negligence and the warranty of the unit shall automatically be voided due to failure to observe proper safety and installation procedures The manufacturer and or distributor reseller will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer PRODUCT Do not remove permanently affixed labels warnings or plates from the product This may void the warranty Do not try to alter the hood INSTALLATION The
2. 5 9 INSTALLAIIDNuuuu l ll lll u onon a e ien aaa e 6 7 10 BAFFLE FILTERS INSTALL amp REMOVAL lll l l 7 11 RANGE HOOD UPERATION L S uu uu u u a a asss 8 10 12 SPECIFICAIIQUNiu ul u u E a ea 10 13 JROUBLESHOOTING uuuuu l u u 10 11 14 USE amp CARE INFORMATION l Lu u u u u aa sagu sSsSSasssssaskusdussiastasusasssSissssss 11 15 MAINTENANCE E 11 16 PRODUCT WARRANIYu u u u uuu akassussassspasssssasapukaabusqakasssasaasspususapusasatassQassusaqcaysuksabasuschusassssssQusqusaqsssuu 12 IMPORTANT NOTICE The Important Safety Instructions and warnings in this manual are not meant to cover all possible problems and or situations that can occur upon installation of this unit Use extreme caution when installing maintaining or operating this or any other appliance Contact the USA LLC Customer Support Team at 1 714 554 9000 email support XtremeAirUsa com with any concerns or situations that you do not understand The manufacturer disclaims all liability for any damage or injury caused as a result of not following instructions for installation contained in this manual r
3. 36 BASE e ALWAYS when possible reduce the number or transitions and turns If a long duct run is required increase duct size from LL 6 to 7 or 8 If a reducer is used install a long reducer instead of a pancake reducer Reducing duct size will restrict decrease airflow e The size of the vent should be uniform Toa Ue tae mm PS FS 5 e Use more than three 90 elbows e Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used 4 VENTING METHODS Horizonal wall venting Vertical roof venting Side wall 5 ck 5 ELECTRICAL REQUIREMENTS IMPORTANT Observe all governing building codes and city ordinances A 120 volt 60 Hz AC 15 amp outlet is needed fused electrical circuit is required It is the customer s responsibility 1 contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards 22 1 94 Canadian Electrical Code Part 1 and 22 2 No 0 M91 latest edition and all local codes and ordinances 6 TOOLS YOU WILL NEED re Wall Keyhole Saw finder ponere Sandia pp AP Pencil or Marker CABINET 2 2 x 4 x 24 1 24 36 42 x 3 4 plywood a Z JACK Note about 6 wider than stove is ok s Z ee S O ee Phillip Screwdrive
4. a AS A gt as PLYWOOD CEILING STEP 2 MARKING ON THE WALL 1 CENTER LINE A Center is the center of cook top or stove B Chimney width is the width of the chimney Varies with each model Mounting screws where the hood body will be positioned from FOR 02 03 amp 08 MODELS please assemble body mounting bracket to the back of hood body first so you can find exact placement location To do so remove 6 screws located on the back of the hood and place the bracket onto the hood with the x same 6 screws Dr MOUNTING SCREW HOLE DIMENSIONS WIDTH PERE WIDTH dimension from center to center of mounting bracket hole HEIGHT dimension from cook top to bottom of range hood varies from 26 to 30 plus from bottom of ranae hood to mounting bracket hole STEP 3 PREPARE DUCTWORK amp SINGLE OUTLET SKIP THIS STEP IF DUCTWORK ALREADY PRESENT x A Have 15 120V 60Hz single outlet anywhere inside the chimney width lines make sure at least 2 inches below ceiling line for ceiling bracket mount x B Have 6 or 8 inch diameter ductwork depending on your model requirements brought down from the ceiling to about the mark of mounting screws 1 2 inches away from wall x is recommended since you need room to plug the unit x STEP 4 INSTALL CEILING BRACKET MOUNTING ANCHORS amp SCREWS x A Plac
5. Atrem lt eaAIR The Advanced Range Hoods INSTALLATION GUIDE amp USER S MANUAL WALL MOUNT RANGE HOOD Pro X Series PX01 W30 36 PX02 W30 36 PX03 W30 36 PX04 W30 36 42 PX04 W30 36 42 B PX06 W30 36 42 48 Ultra Series DO2 W30 36 ULO2 W30 36 ULO3 W30 36 Deluxe Series DLO8 W36 42 48 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL amp INDOOR USE ONLY www xXtremeAirUsa com PAGE 1 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS 2 2 HEIGHT amp CLEARANCE sscecsscessccpsscstessecesseapscaatecsacnanssgansaieasacasieapnaesiedenessseasetesicadsienaescueesnadasinsteassceabestaceadesacnasaassaeeze 3 3 WENTING REQUIREMENT ssscssscesesccasccssescaassuacetessssceseceossetasscaseacdseivesustouscdasatisesencbecedesandseanwacdecdesabacebandessseasosaswtesdeasaes 3 4 VENTING METHODS u u uu Z 3 5 ELECTRICAL REQUIREMENT uuu ukasa aakssssssssasuasbussskasssssqababusussaisayasqastpswukasssssqebsbususssasayssuastuswukassssus 3 6 TOOLS YOU WILLNEEDu l u u u u a S d 3 7 PARISSUPPLIIEDI III A A E 4 8 DIMENSIONS amp INSTALLATION OVERVIEMW
6. BLUE L to activate delay off timer Power Off Delay Timer Indicator 10 will light up and Power Off Delay Digital Timer 9 will begin to countdown When it reaches zero the blower motor will shut down G TO CLEAR CLEANING REMINDER e When blower motor starts to rotate cumulative running time will be shown in Power On Elapsed Digital Timer 8 This timer icon flashes when 30 hours is up and reminds user to clean the baffle filters e After cleaning the filters and when the motor is in use touch and hold ncrease Value button 7 over 3 seconds to reset the timer Please note that turning off the system will not reset the Power On Elapsed Digital Timer 8 www xXtremeAirUsa com PAGE 9 3 FOR ALL ULTRA SERIES TYPE 3 MECHANICAL BUTTON CONTROL A Activating Blower Function i ePress your designed speed 1 2 3 B Turn off power eWhile the blower motor is running press button 0 to turn off the motors 2 3 Blower Speed C To turn the light ON OFF eWhile the light is off press button 4 once to turn on the light Press button 4 again to turn the light off 4 FOR DL08 amp DLO9 Model TYPE 4 ELECTRONIC BUTTON CONTROL O O Activating Blower Function 0 Sr eK amp Press 0 once flashing 2 ePress your designed speed 1 2 3 4 Light On Off B Active delay power shut off turn off power eWhile the blower motor is running press 0 once to active 3 min powe
7. C Install new light bulb D Put the light set back by pressing it in E Plug in and range hood fo test for operation 2 The range hood vibrates when the blower is on e The range hood might not have been secured properly to the cabinet or wall e Check if the blower wheel is damaged www XxtremeAirUsa com PAGE 10 3 The blower or fan seems weak e Check that the duct sized used is at least 6 Range hood WILL NOT function efficiently with insufficient duct size amp loosely secured e Check if duct is clogged or if damper unit half circular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow 4 The lights work but the blower is not spinning at all is stuck or is rattling e The blower might be jammed or scraping the bottom due to shipping damage Please contact us immediately 5 The hood is not venting out properly e Make sure the distance between the stove top and the bottom of the hood is within 26 and 30 in distance e Reduce the number of elbows and length of ductwork Check if all joints are properly connected sealed and taped e Make sure the power is on high speed for heavy cooking 6 The hood is noisier than normal e The damper was not opened e The duct is not secure and causes vibration e The smaller duct size than required is being used 7 Control panel is not active e Check to make sure the auto function is no
8. 2 1 2 HOUR AUTOMATIC SHUT OFF this range hood will be shut off for every approx 2 1 2 hour You can re start operation as usual after it was shut off 2 30 HOUR REMINDER after 30 hours of use the timer 8 will be flashing To clear it please refer to G To Clear Cleaning Reminder on page 7 A ACTIVATING BLOWER FUNCTION e Option 1 Touch and hold down for 1 2 seconds e Option 2 Touch and hold down power sign 1 for 1 2 seconds The blower will be running at the same speed as last used Note The system saves user configurations settings such as timer and blower motor speed will remain the same the next time it is turned on B ADJUSTING BLOWER SPEED e Touch and hold down for increase e Touch and hold down for decrease C TURNING OFF THE BLOWER e Touch and hold down power sign 1 for 1 2 seconds D TO TURN THE LIGHT ON OFF e Touch Light button 6 once to turn on the lights and once again to turn off the lights E ADJUSTING THE TIMER FUNCTION e While the blower motor is not running touch and hold Decrease Value button 2 1 2 seconds or until it s flashing to enter timer mode e Adjust to desired period of delay off timer by touching Increase Value or Decrease Value button minimum 1 minute to maximum 15 minutes This setting will be saved immediately F ACTIVATING THE TIMER FUNCTION e While the blower motor is running touch and hold Power button 1 for 1 2 seconds til you see
9. L Please reverse the process A OPEN While holding a baffle filter pull baffle filter lock down www XtremeAirUsa com PAGE 7 11 RANGE H00D OPERATION IMPORTANT BEFORE YOU BEGIN 1 For TOUCH SENSITIVE CONTROLS please DO NOT PRESS A light touch and hold on the required button for a matter of a 1 one second is all that is needed CORRECT INCORRECT 2 TOUCH THE ENTIRE BUTTON See illustration on right For best results Start the range hood before cooking and allow it to operate several minutes after the cooking is completed to clear all smoke and odors from the kitchen Entire button covered and lightly touched Button is NOT completely covered 1 FOR PX02 amp PX06 Model 7 TOUCH SCREEN CONTROL PANEL Light ON Indicator Blower ON Indicator Power Off Delay Indicator Auto Function ON Indicator O 9 D Light LCD Panel Decrease Power Off Delay J Remote Control Sensor uto Function Importance ___ TYPE 1 TOUCH SCREEN CONTROL 1 AUTO FUNCTION ACTIVE Once Auto Function is on or touched all other functions will be DE ACTIVATED and will NOT be working 2 2 1 2 HOUR AUTOMATIC SHUT OFF This range hood will be shut off for every approx 2 1 2 hours You can re start operation usual after it was shut off 3 SCREEN TURN OFF This range hood is equipped with remote control and smoke sensor that will self calibrate within 5 seconds when th
10. e center of ceiling mount bracket in line with center line and all the way up to the x ceiling Once in place secure with screws Pre drill holes 1 8 where your mounting marks are Slowly tighten wall anchors 2 total until it is flush with the wall surface D Insert mounting screws inside the wall anchors then slowly tighten it down Make sure to eave about 1 8 space away from the wall to the inside screw s head STEP 5 HANG THE HOOD amp CONNECTION Carefully lift and hang the hood body on the wall attaching it to 2 mounting screws already in place Level the hood body by using horizontal level Use hand screw driver to tighten those 2 mounting screws Connect the exhaust on the hood to the ductwork above Use aluminum tape to make all joints secure and all tight Find the three pronged plug and connect to an electrical outlet CAUTION Do not release the hood until you finish step 6 below www XtremeAirUsa com PAGE 6 STEP 6 SECURE THE HOOD BODY amp TEST RUN Use a stud finder to find all studs below the hood body Put blue tape on every stud found Use 1 8 drill bit to drill though the back of hood in line with blue tape Secure the hood body by using the 2 0 inches wood screws provided through the back of hood to the stud Refer to page 8 Range Hood Operation Try a few test runs to ensure machine is running properly FOR PX01 MODEL ONLY INSTALL GLASS CANOPY L
11. e range hood is first electrically activated Self calibration will be set when the range hood beeps LCD panel WILL TURN OFF automatically after a period of inactivity and every time when plugged into electrical outlet A ACTIVATING NORMAL BLOWER FUNCTION S While the range hood is off Touch to start from lowest speed FI Touch to start from Highest speed F4 Increase Touch or again to change the blower speed as indicated in LCD panel 00 blower off Fl quiet speed F2 low speed F3 medium speed F4 high speed Decrease B Activating Light Function Light Touch Light button to turn the lights on or off C Activating Power Off Delay Function 1 While the range hood is and the blower is running in normal mode touch Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay of timer by touching or button quickly 1 15 minutes Timer begins to countdown immediately when it reaches 0 the blower will shut off 3 Display screen will show flashing clock if timer is working D Activating Smoke Detector Function While the machine is off touch Auto Function button to activate the smoke detector auto function mode NOTE this function will only worked when there s a lot of smoke this button is touched all other buttons are not active Auto Function E Changing the clock only available in some models While the blower is off 1 Touch powe
12. ease tunnel oil container regularly Regular care will help preserve the appearance of the range hood Cleaning Exterior surfaces Clean periodically with stainless steel cleaner or hot soapy water and clean cotton cloth Do not use corrosive or abrasive detergent e g Comet Power Scrub EZ Off oven cleaner or steel wool scoring pads which will scratch and damage the stainless steel surface For heavier soil use liquid degrease such as Formula 409 or Fantastic brand cleaner If hood looks splotchy stainless steel hood use a stainless steel cleaner to clean the surface of the hood Avoid getting cleaning solution on or into the control panel Follow directions of the stainless steel cleaner CAUTION Do not leave on too long as this may cause damage to hood finish Use soft towel to wipe off the cleaning solution gently rub off any stubborn spots Use dry soft towel to dry the hood After cleaning you may use non abrasive stainless steel polish such as or ZEP to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth and with the grain DO NOT allow deposits to accumulate or remain on the hood DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contai
13. installation in this manual is intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professionals and in accordance with all applicable codes and standards including fire related construction When cutting or drilling into the wall or ceiling do not damage electrical wiring and other utilities It is recommended that two or more people assist with the installation The range hood may have very sharp edges please wear protective gloves if it is necessary to remove any parts for installing cleaning or servicing VENTING For kitchen range or cook top ventilating use only DO NOT use units to exhaust hazardous or explosive materials and vapors Ducted fans MUST always be vented to the outdoors DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics and or garages Use only metal ductwork Old duct work should be cleaned or replaced if necessary to avoid the possibility grease fires Check all joints on ductwork to insure proper connections All joints should be properly taped ELECTRICAL All electrical wiring must be properly installed insulated and grounded TURN POWER OFF and un plug cords from outlet before servicing and or cleaning to insure your safety OPERATION Caution is suggested when using high settings on cooking range Keep all fan baffle spaces filter grease tunnel oil container and grease laden surfaces c
14. lean Grease should not be allowed to accumulate on fan baffle spaces filter grease tunnel and oil container Never allow the filters to become blocked or clogged Do not allow foreign objects such as cigarettes and or napkins to be absorbed into the hood Clean ventilating fans frequently Grease should not be allowed to accumulate on the fan or filters www XtremeAirUsa com PAGE 2 2 HEIGHT amp CLEARANCE 3 VENTING REQUIREMENTS IMPORTANT e NEVER exhaust air or terminate ductwork into crawl spaces between walls ceiling attics or garages All exhaust must be ducted to the outside e Hood mounted too low could result in heat and or fire hazard Hoods mounted too high will be hard to reach and will lose its performance and efficiency Use metal ductwork only DO NOT use plastic ventilation DO NOT use 4 10 2 cm laundry type wall caps Fasten all connections with sheet metal screws Tape all joints with aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If the roof or wall cap has a damper you may opt out from usage of your range hood supplied damper for some models only For the most efficient amp quiet operation COOK TOP e distance of 26 to 30 is recommended between stove top and the bottom of range hood e It is recommended that the range hood be vented vertically through the roof with a minimum of a 6 or larger vent work
15. n chemicals which may be harmful Rinse with water after exposure and wipe dry with a clean cloth Cleaning Grease Filter Stainless Steel Filter less Grill IMPORTANT Drain oil from oil containers before oil and residue overflow The metal filters fitted by the factory are intended to filter out residue and grease from cooking It needs not be replaced a regular basis but are required to be kept clean Filters should be cleaned after every 30 hours of use Remove and clean by hand or dishwasher Use proper degreasing detergent for stainless steel and leave to soak if heavily soiled Dry filters and re install before using hood www XtremeAirUsa com PAGE 11 16 LIMITED WARRANTY XtremeAIR USA HOOD TEN 10 YEARS MOTOR LIMITED WARRANTY XtremeAir USA Range Hood hereunder called The Company warrants its product against defects in material or workmanship for the time periods and as set forth below Parts For a period of two 2 years from the original date of purchase of product Parts Warranty The Company will supply new or equivalent replacement parts in exchange for parts determined to be defective The motor warranty is extended for an additional eight 8 years to accumulate of ten 10 years total motor only Labor For a period of one 1 year from the original date of purchase of the product Labor Warranty if the product is determined to be defective The Company will repair or replace the product atit
16. oosen the four canopy screws and washers from the hood top Carefully place the canopy glass on the hood top then slightly tighten the four canopy screws along with washers DO NOT put excessive pressure against the glass Lift up and attach the innner chimney to the ceiling mounting bracket Remove outter chimney protective film not the inner chimney Place both chimneys on of range hood base NEXT Screw the chimney into Secure outside chimney place on both sides to the base of the hood Remove inner chimney PX02 amp 0108 ONLY protective film 10 BAFLE FILTERS INSTALL amp REMOVAL IMPORTANCE FOR THOSE MODELS THAT HAVE MORE THAN 2 BAFFLE FILTERS ALWAYS INSTALL THE MIDLE FILTER LAST WHEREAS REMOVE IT FIRST IF YOU ARE TRING TO REMOVE ALL OTHER FILERS Install amp Remove Baffle Filters k iL OIL TUNNEL Drop oil tunnel into recess Angle baffle filter 2 Lift a baffle filter up above horizontal level support near rear of hood toward back of then slide forward into slot behind the front of Note PX04 amp PX06 skip this step hood hood To remove please reverse the process TO REMOVE While a baffle filter is open use both hand to hold both end of it then use your index finger either left or right to push baffle filter hinge pin toward to middle of baffle filter to release it TO INSTAL
17. perty of The Company This Limited Warranty only covers product issues caused by defects in material or workmanship during ordinary consumer use or non transferable it does not cover product issues caused by any other reason including but not limited to product issues due to commercial use acts of God misuse defects resulting from damages sustained during shipping unauthorized repair modification of or to any part of the XtremeAir product This Limited Warranty does not cover XtremeAir products sold AS 15 WITH ALL FAULTS light bulbs remote control norma maintenance and service costs of removal installation This Limited Warranty is invalid if the factory applied seria number has been altered or removed from the product DISCLAIMERS XtremeAir USA LLC shall not be responsible for loss of use or other incidental consequential costs expenses or damages which may occur Under no circumstances shall XtremeAir USA LLC or any of its representatives be held liable for injury to any person or damage to any property however arising This warranty gives you specific legal rights and you may have other rights which vary from state to state All rights reserved to XtremeAir USA LLC XtremeAIR Warranty 6 1 13 www XtremeAirUsa com PAGE 12
18. r yy www XtremeAirUsa com PAGE 3 7 7 PARTS SUPPLIED SUPPLIED PART SKETCH DESCRIPTION MANUAL BOOK PX02 PX03 PX04 B ULO2 ULO3 ATTACH ATTACH ATTACH ED ED ED DL08 DL08 W48 UPPER INNER CHIMNEY LOWER OUTER CHIMNEY CEILING MOUNTING BRACKET BODY MOUNTING BRACKET ATTACH WALL WALL ANCHOR SCREW UPPER INNER 4 4 4 4 4 CHIMNEY SCREW wc ATTACHED ATTACHED ATTACHED ATTACHED ATTACHED ATTACHED ATTACHE CAPONY GLASS BAFLE FILTERS ATTACH ATTACH ED ED ATTACH mi mi 2 PCS _ REMOTE CONTROL NOTE ATTACHED MEAN THE PARTS HAVE BEEN ATTACHED OR SCREW ITS LOCATION www XtremeAirUsa com PAGE 4 8 HOOD DIMENSIONS amp INSTALLATION OVERVIEW PX04 W30 36 42 amp PX06 W30 36 42 PX08 W36 42 a 4 Ceiling mount bracket screw Ceiling mount bracket Inner chimney nner chimney screw Aluminum pipe Outer chimney Oil container Control panel Baffle filters www xXtremeAirUsa com PAGE 5 1 OPTIONAL ONLY PROTECT THE amp CREATE WORK STATION Have 2 pieces 2 x 4 x 20 on both sides of stove amp plywood on top of them to protect cook top or stove from damage or debris This plywood will also create a comfortable work station for easy installation of hood unit
19. r delay shut off ePress 0 again to turn off blower and power To turn the light amp Dimmer eWhile the light is off press 5 once to turn on the light ePress 5 again to turn dimmer down to lower setting ePress 5 again to turn the light off 0 Power On Off Power Delay Blower Speed 12 SPECIFICATION DLO9 W48 Body Design Non Magnetic 1 0 mm Stainless Steel Satin Finish Power Rating 120V 60Hz USA amp Canada standard General Input Power 308W 150W 4x2W Motor Input Power 150 W each Ampere 2 6 A Levels Of Speed Control 4 Levels Maximum Airflow 1600CFM Noise Level Approximately 3 0 7 0 sones or 41 56 dB Number Of Motors 2 Motors Motor Type Single Chamber Ultra Quiet Fan Type 2 Squirrel Cage blowers Filtration Type Heavy Duty Stainless Steel Baffle Filter 4 LED lights 2W Maximum each Venting Size Top 8 inches Round Interference Protection Radio Frequency Interference Protected Specification subject to change without notice Specification subject to change without notice 13 TROUBLESHOOTING 1 If the range hood or lights does not operate after installation e Check if the range hood has been plugged in Make sure that all power has been turned back ON e Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs A Make sure the range hood is unplugged or turn OFF breaker B Pop out the light by pressing behind the light fixture
20. r sign once The hour indicator will be flashing 2 Use or to adjust to the desired hour 3 Touch power sign again for the minutes Indicator will be flashing 4 Use or to adjust to desired minutes 5 Touch power sign again to clear the screen Touch light button to validate To check time touch light button NOTE The clock display is only available for product manufactured after October 2013 www xXtremeAirUsa com PAGE 8 F Remote Control Sensor 1 Remote control sensor receives infrared IR signal from the remote control The maximum distance for IR data transmission is 10 feet and requires direct line of sight The transmission distance may vary depending on temperature and remote control battery condition 2 Light settings are independent from other settings including power off delay and lights have to be manually turned on or off 3 The system saves user configurations settings such as light timer and blower motor speed will remain the same the next time it is turned on 2 FOR PX03 PX04 PX04 B amp D02 Model TYPE 2 BUTTON TOUCH CONTROL PANEL 6 LT ight 7 Increase Value Power On Elapsed Digital Timer Power Off Delay Digital Timer 5 power Ofr Delay Timer Indicator 1 Power Decrease Value 2 Blower Power Indicator 3 Blower Speed Indicator 4 Light Power Indicator Importance Notice 1
21. s option at no charge After the Labor Warranty period labor charges are applicable Warranty Performance In the event of any malfunction or defect covered under the terms of this warranty immediately contact the company Written notice of any malfunction or defect must be given within 7 days of the time of the discovery of the malfunction and must be accompanied by the original consumer purchase receipt which Please complete the Product Registration Card and return it with the dated bill of sale or other evidence of the original proof of purchase within 30 days from purchase of the product to address shown below to protect your investment To obtain warranty service the products must be delivered freight prepaid in either its original packaging or packaging affording an equal degree of protection to the company authorized service facility specified as below The repaired unit will be returned at the company expense 309 N Harbor Blvd Santa Ana CA 92703 USA For specific instructions how to obtain warranty service for your product Visit XtremeAir USA s Web Site www XtremeAirUsa com Warranty Or call XtremeAir USA Customer Information Service Center 1 714 554 9000 Repair Replacement Warranty This Limited Warranty shall apply to any repair replacement part or replacement product for the remainder of the original Limited Warranty period Any part or product replaced under this Limited Warranty will become the pro
22. t on 14 USE amp CARE INFORMATION Operations e Read and understand all instructions and warnings in this manual before operating the appliance Save these instructions for future reference e Always leave safety grills and filters in place Without these components operating blowers could catch on to hair fingers and loose clothing e NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers e NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times e NEVER cook on open flames under the range hood Check deep fryers during use Superheated oil may be flammable Cleaning e The saturation of greasy residue in the blower and filters may cause increased inflammability Keep unit clean and free of grease and residue build up at all times to prevent possible fires e FILTERS MUST BE CLEANED PERIODICALLY AND FREE FROM ACCUMULATION OF COOKING RESIDUE e DO NOT operate blowers when filters are removed Never disassemble parts to clean without proper instructions Disassembly is recommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding 15 MAINTENANCE SAFETY WARNING Never put your hand into area housing the fan while the fan is operating For optimal operation clean range hood and all baffle spacer filter gr
Download Pdf Manuals
Related Search
Related Contents
細 貝 建 築 事 務 所 長岡市教育委員会 教育施設課 Catalogo 2015 User Manual - The Source MDGSMI (user manual) manuel d`installation, utilisation et entretien four Copyright © All rights reserved.