Home
EXPERT PRO INTEGRA PRO 250 500 1000 250 PLUS
Contents
1. Integra 250 Plus 500 Plus 1000 Plus Kompaktblitzger t Compact flash unit A DN d Aj BEDIENUNGSANLEITUNG USER MANUAL WWW HENSEL DE HENSEL MM MBM PERFORMING LIGHT Sl el ch UL vi Integra Plus Bedienpanel Front panel a TR te pe 20 19 gt Strobe Wizard Plus freemask f r Funkfernausl sung und Blitzsteuerung Sender Strobe Wizard Plus freemask for radio flash triggering and power control transmitter 25 26 24 23 STROBE WIZARD PLUS Transmitter C Made in Germany Code 3950 21a LEITER Bedienpanel front panel Strobe Wizard Plus R ckansicht back view Seitansicht side view Transmitter Made in Germany Code 3955 freemask TIE Bedienpanel front panel freemask R ck und Seitansicht sind identisch mit dem Strobe Wizard Plus Back and side view are identical to the Strobe Wizard Plus Bedienungsanleitung Integra Plus Kompaktblitzgerat HENSEL MMM MM PERFORMING LIGHT HENSEL VISIT GmbH amp Co KG Robert Bunsen Str 3 D 97076 Wurzburg Lengfeld GERMANY Tel 49 0 931 27881 0 Fax 49 0 931 27881 50 E Mail info hensel de Internet http www hensel de 4 HENSEL VISIT GmbH amp Co KG Bedienungsanleitung Integra Plus Kompaktblitzgerat Bedienungsanleitung Integra Plus Kompaktblitzgerat Stand 09 2013 Seite 6 User manual Integra Plus Compact flash unit Date of revision 2013 09 p
2. In case of choosing the All option on the transmitter all flash units are triggered independently from the working channels selected Flash power adjustment and changing modeling light options The buttons 21a and 21b allow further options for Hensel flash units with a built in receiver A single click on the respective button reduces and increases the flash power by 1 10 f stop Pressing button 21a for longer than 3 seconds switches the modeling light from FULL to OFF and PROP respectively The receiver is equipped with an interface socket 30 for Hensel power packs Maintenance The Hensel remote control system Strobe Wizard Plus is almost maintenance free Because of the low energy consumption of the transmitter a battery lifetime of 1 to 2 years can be assumed depending on the degree of utilization The battery of the radio transmitter can be exchanged by unscrewing screw 26 at the bottom of the unit This provides access to the electronics and the battery can be removed from the clips and exchanged HENSEL VISIT GmbH amp Co KG 45 User manual Integra Plus Compact flash unit N ek D freemask transmitter Code no 3955 46 Before reinstallation of the new battery the polarity must be observed The positive pole should be pointed toward the Power Down 21a button Technical data Transmitter Type Strobe Wizard freemask Plus Code No 3950 3955 Sync
3. controls front panel 1 ON main switch ON OFF 2 RC remote control switch and ON indicator 3 AUDIO acoustical ready signal and ON indicator 4 FC flash check switch and ON indicator 5 SLAVE slave switch and ON indicator 6 TEST Manual flash release with ready indicator 7 Sync socket 8 Slave 9 Fuse4A 10 Mains connector Bi voltage 110 V and 230 V 11 FULL modeling lamp operation mode and ON indicator 12 PROP modeling lamp operation mode and ON indicator 13 Flash power control switch 14 LED display Tilting head components 15 Cable fixation 16 Hole of the umbrella holder 17 Shifting of the tilting head to balance heavy loads 18 Clamping screw to hold umbrellas 19 Star screw for attaching unit to a stand 20 Fixing bracket Radio transmitter controls 21a Flash power down and modeling light options 21b Flash power up button 22 Channel selector for 3 channels All option sliding switch 23 Test button for flash triggering 24 Socket for sync cable 2 5 mm 25 Locking screw for mounting to the hot shoe of the camera 26 Screw for opening the battery compartment The radio transmitter is not included in the standard delivery and has to be ordered separately Code no 3950 or 3955 36 HENSEL VISIT GmbH amp Co KG User manual Integra Plus Compact flash unit 7 Starting up Safety hints for operation with compact flash units To avoid damage to the flash tube mount reflectors and lig
4. Wegen der W rmeentwicklung darf das Kompaktger t nicht in der N he von entflammbaren Gegenst nden be trieben werden Bei Dekorationen f r fotografische Zwecke ist auf ausreichenden Sicherheitsabstand zu ach ten Dar ber hinaus ist es notwendig stets f r ausreichende Luftzufuhr zu sorgen und die L ftungsschlitze des Kom paktger tes frei zu halten Blitzger te d rfen nicht unbe aufsichtigt betrieben werden Das Einstelllicht darf nicht als Ersatz f r Studiobeleuchtung verwendet werden sondern dient als Hilfe beim Scharfstellen des Objektivs bzw zum Absch tzen des Licht Schattenverlaufes des Blitzlichtes Akklimatisierung Bei Standortwechsel des Blitzger tes mit Klimawechsel sollte das Ger t vor Inbetriebnahme einige Zeit in dem Raum stehen in dem es benutzt wird Dadurch werden evtl Kriechstr me durch Feuchtigkeitsniederschlag ver mieden Aufstellung Integra Plus Kompaktblitzger te werden standardm ig mit Schwenkneiger geliefert Der Neiger kann ber eine der beiden um 90 versetzten Offnungen an einem Stativ einer Schere o angebracht und mittels der Stern schraube 19 sicher verschraubt werden Zur Neigungs einstellung dient der Feststellgriff 20 In die Offnung 16 oberhalb des Feststellgriffs kann ein Schirm eingef hrt und durch Anziehen der Klemmschraube 18 sicher befestigt werden F r das Anbringen schwerer Lasten am Blitzger t kann es vorteilhaft sein zum Gewichtsausgleich den Neiger innerh
5. 6 EST 11 12 FULL PROP 42 The selected channel of the transmitter and receiver must correspond to each other Flashes can be triggered by pressing the TEST button or by releasing the camera shutter For a detailed description of the radio control system please refer to chapter 9 Test Flash By pressing the button 6 test flashes can be released Flash power control The desired flash power can be set in 1 10 f stops over a range of 6 f using power control switch 13 The setting is shown on the LED display 14 presenting values ranging from 5 0 minimal flash power to 10 0 maximum flash power Flash readiness Flash readiness of the compact flash unit is shown by e green light of the READY lamp above TEST button 6 e modeling lamp turned on when Flash Check mode is activated switch 4 e acoustical signal when AUDIO 3 is switched on APD system In case of reducing the flash power the stored energy will be discharged by APD system Automatic Power Drop No flash will be triggered After switching off the compact flash units will be discharged automatically It is also possible to reduce the stored energy by simply triggering a TEST flash by pressing button 6 Modeling lamp The operation mode for the modeling light can be selected by pressing the buttons 11 or 12 By pressing the FULL button 11 the maximum modeling light output is set By pressing the PROP button 12 the modeling light Output is proportio
6. Anschlag dr cken Jetzt das Zubeh rteil plan und b ndig an das Ger t an setzen Dabei nicht verkanten Anschlie end den Hebel zum Verriegeln in Richtung der Federkraft in die Aus gangsposition zur ckbringen Zum L sen Zubeh rteil fest halten Vorsicht dies k nnte sehr hei sein den Hebel zum Entriegeln nach links dr cken und Zubeh r ab nehmen Schirmhalter Am Neigekopf des Kompaktger tes ist ein Schirmhalter mit Federklemm Mechanismus oberhalb des Schwenk neigers integriert Dieser erm glicht das Anbringen unter schiedlicher Hensel Blitzschirme und des Softstars Zur Befestigung des Schirmes dient die Feststellschraube 18 HENSEL VISIT GmbH amp Co KG 15 Bedienungsanleitung Integra Plus Kompaktblitzgerat b 10A AO 16 Netzanschluss Achtung Vor Anschluss des Kompaktblitzgerates an das Stromnetz muss sichergestellt sein dass die Netzspannung mit den Angaben auf dem Typenschild des Kompaktblitzger tes bereinstimmt Das Typenschild befindet sich am Geh u seboden Alle Integra Plus Kompaktger te sind mit Bivoltage Technologie ausgestattet d h das Ger t passt sich automatisch der jeweiligen Netzspannung an 110 V und 230 V Das mitgelieferte Netzkabel wird durch den Griff gef hrt an Buchse 10 angeschlossen und anschlie end mit dem Stromnetz verbunden Die Kabelklemme 15 dient zur Fixierung des Kabels Kompaktblitzger te d rfen nur an geerdete Strom netze angeschlossen
7. Therefore protect the equipment from humidity The operation during rain is not recommended because over the years moisture might ingress into the housing causing damage to the electronics Start up and channel selection built in receiver By pressing the RC button 2 the built in receiver of the Integra Plus units is switched on The channel can be selected by pressing the flash control switch 13 once By turning the knob channels from 1 to 3 can be selected as shown on the LED display 14 After 3 seconds delay or by pressing switch 13 again the channel is set and the dis play changes to the flash power setting HENSEL VISIT GmbH amp Co KG 21a 21b User manual Integra Plus Compact flash unit Start up and channel selection transmitter The radio transmitter has no built in main switch for switching the unit ON The transmitter is to be connected to the camera either by attaching it to the hot shoe of the camera or by connecting the camera to the synchro nization socket 24 using the provided synchronization cable If the transmitter is connected to the hot shoe the unit must be tightened carefully using the locking screw 25 The working channel can be selected using the sliding switch 22 There are 3 working channels available and the option All Flash triggering Depending on the working channel selected the flash can be triggered by pressing the TEST button 23 or by releasing the camera shutter
8. der Richtlinie des Rates vom 03 Mai 1989 zur Angleichung der Rechtsvorschriften der Mitgliedsstaaten ber die elektromagnetische Vertr glichkeit 2004 108 EC vom oben genannten Hersteller abgegeben Die Erkl rung macht keine Aussagen in Bezug auf die Schutzanforderungen zur elektromagnetischen Vertr glichkeit nach anderen Rechtsvorschriften die der Umsetzung anderer Richtlinien der Europ ischen Union als der EMV Richtlinie dienen Pr fbeschreibung Niederspannungsrichtlinie Pr fstandards EN 60065 2002 A1 2006 Cor 2007 A11 2008 EN 60598 1 2008 A11 2009 EN 60598 2 9 1989 A1 1994 EN 50371 2002 Diese Konformit tserkl rung wird gem Artikel 10 Abs 1 der Richtlinie des Rates vom 19 Februar 1973 zur Angleichung der Rechtsvorschriften der Mitgliedsstaaten betreffend elektrischer Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen 2006 95 EG vom oben genannten Hersteller abgegeben Diese Erkl rungen beziehen sich auf das oben beschriebene Produkt Datum der Konformit tserkl rung 29 4 2010 G sch ftsf hrer HENSEL Studiotechnik GmbH amp Co KG User manual Integra Plus Compact flash unit 1 Introduction Dear photographer with buying a Hensel flash system you have pur chased powerful equipment of high quality So that you are able to work successfully and productively with this system for many years we are giving you some advice on the use of this high tech product Only by observance o
9. socket 2 5 mm jack plug Mono Sync voltage 3V Sync current lt 1mA for 5 us Channels 3 selected by sliding switch Shutter time for 1 250 s synchronization Dimensions in cm width x length x height SARERA Weight with battery 53 g Type of battery 28L 6V 1 pc Battery life 1 2 years Range gt 40 m 131 feet free visibility Frequency 433 92 MHz This product conforms to the radio standards ETSI EN300220 and FCC15 231 freemask Channel selection An additional function is available when selecting the channel click flash energy regulator 13 once the channels F1 F2 and F3 can be set additionally besides the channels C1 C2 and C3 When using the compact flash units for normal lighting of a set with the channels C1 C2 and C3 you can trigger the flash via radio remote adjust the modelling light and set the flash power via radio remote control just like you have been used to so far The freemask application for the second group of flash units does not allow you to switch the modelling light or the flash power via radio remote You can only use the channels F1 F2 and F3 to differentiate between up to three different separate work stations HENSEL VISIT GmbH amp Co KG User manual Integra Plus Compact flash unit Channel selection for one work station Please set all flash units used to light the set to C channels in order to trigger the automatic synchronized fl
10. to be ordered separately Code no 3950 or 3955 HENSEL VISIT GmbH amp Co KG 5 Technical data User manual Integra Plus Compact flash unit Series Integra Plus Model type 250 500 1000 Values attained at 230 V 50 Hz Rated energy 250 J 500 J 1000 J Aperture at 100 ASA t 1 60 45 8 10 64 8 10 90 9 10 1 m distance 2m 12 reflector 22 8 10 32 8 10 45 9 10 Flash duration in sec t 0 5 1 2 380 1 1 390 1 1 680 Recycling time 100 power 1 3 1 9 2 1 In sec 1 32 power 0 3 0 5 0 45 Flash tube U flash tube for plug in single coated Power adjustment in 1 10 f over 6 f adjustable 1 1 1 32 Modeling lamp max 300 W G 6 35 halogen lamp Modeling light adjustment FULL OFF and PROP mode over 6 f glass dome clear uncoated plug in coated flash tube fan tilting head adjustable umbrella holder Features transportation protection cap built in receiver Strobe Wizard Plus and freemask illuminated front panel Fuse 4 AF Mains connection Bi voltage 110 V and 230 V Weight kg 2 75 2 87 3 90 Measurements in cm without handle L x B x H 33x15x23 33x15x23 39 5x 15x 23 Code No 8814FM 8815FM 8816FM Technical changes reserved Effective date September 2013 HENSEL VISIT GmbH amp Co KG 35 User manual Integra Plus Compact flash unit 6 Overview of controls Compact flash unit
11. transmitter automatically defaults to one picture after 200 ms This is not dependent on the actual number of exposures This ensures that the set lighting is always the first exposure and the mask lighting the second exposure when using the freemask application HENSEL VISIT GmbH amp Co KG 47 User manual Integra Plus Compact flash unit 48 10 Maintenance The Integra Plus compact flash series is in need of little maintenance by the user The unit should be dry cleaned from dust from time to time Before cleaning separate the unit from the mains outlet Caution Under no circumstances is any part of the equipment to be opened The equipment is not user serviceable and there is dangerous high voltage In the event of difficulty notify your dealer Replacement of fuses In case of a broken fuse 9 replace fuse only when the unit is switched off and separated from the mains outlet Attention Never repair or bridge fuses Only use fast fuses with the required value Fuse for operation with modeling light 300W G6 35halogen 4 AF 5x20 mm Only use fuses in accordance with EN 60127 2 1 or respectively IEC 127 2 1 A wrong fuse may cause a bursting of the halogen modeling lamp Replacement of modeling lamp Attention Turn the unit off and disconnect it from any power supply before replacing the modeling light Wait at least 15 minutes before continuing the procedure and until the halogen lamp has cooled of
12. 0 Leistung 1 3 1 9 2 1 1 32 Leistung 0 3 0 5 0 45 Blitzrohre U Blitzr hre steckbar einfach beschichtet Regelung Blitzenergie In 1 10 f Uber 6 f einstellbar 1 1 1 32 Einstelllicht max 300 W G 6 35 Halogen Regelung Einstelllicht FULL OFF und PROP Uber 6 f Glasglocke klar unbeschichtet Blitzr hre steckbar einfach beschichtet L fter Neiger verschiebbar Ausstattungsmerkmale Schirmhalter Transportschutzkappe eingebauter Funk Empf nger Strobe Wizard Plus und freemask beleuchtetes Bedienpanel Absicherung 4 AF Netzanschluss Bivoltage 110 V und 230 V Gewicht kg 2 75 2 87 3 90 Ma e ohne Griff in cm LxBxH 33 x 15 x 23 33x 15x23 39 5x 15x 23 Art Nr 8814FM 8815FM 8816FM Technische nderungen vorbehalten Stand September 2013 HENSEL VISIT GmbH amp Co KG 11 Bedienungsanleitung Integra Plus Kompaktblitzgerat 6 Ubersicht der Bedienelemente Bedienelemente Kompaktgerat 1 ON Hauptschalter ON OFF 2 RC Schalter Remote Control mit EIN Indikator 3 AUDIO Akustische Ready Anzeige mit EIN Indikator 4 FC Schalter f r Flash Check mit EIN Indikator 5 SLAVE Schalter f r Fotozelle mit EIN Indikator 6 TEST Blitzhandausl6sung und Ready Anzeige 7 _Synchronbuchse 8 Fotozelle 9 Absicherung 4A 10 Netzanschlussbuchse Bivoltage 110 V und 230 V 11 FULL Betriebsart f r Einstelllicht mit EIN Indikator 12 PROP Betriebsart f r Einstelllich
13. 3 962 754 02203 962 755 089 310 1428 089 310 949 2 HENSEL VISIT GmbH amp Co KG Konformitaetserklaerung E XPERT INTEGRA Pro Plus doc EG Konformitatserklarung ber Funk und Telekommunikationseinrichtung elektromagnetische Vertr glichkeit und elektrische Sicherheit Hersteller HENSEL Studiotechnik GmbH amp Co KG Robert Bunsen Str 3 97076 W rzburg Germany Inhaber der HENSEL Studiotechnik GmbH amp Co KG Bescheinigung Robert Bunsen Str 3 97076 W rzburg Germany Pr fbericht vom 27 4 2010 Objektbezeichnung EXPERT Pro 250 Plus INTEGRA Pro 250 Plus Integra 250 Pius EXPERT Pro 500 Pius INTEGRA Pro 500 Plus Integra 500 Plus EXPERT Pro 1000 Plus INTEGRA Pro 1000 Plus Integra 1000 Plus Pr fbeschreibung Funk und Telekommunikationseinrichtung Pr fstandards EN 300220 2 V 2 1 2 Diese Konformit tserkl rung wird gem Artikel 3 der Richtlinie des Rates zur Angleichung der Rechtsvorschriften der Mitgliedsstaaten von Funkanlagen und Telekommunikationsendeinrichtungen R amp TTE 1999 5 EC vom oben genannten Hersteller abgegeben Die Erkl rung macht keine Aussagen in Bezug auf die Schutzanforderungen zur elektromagnetischen Vertr glichkeit nach anderen Rechtsvorschriften die der Umsetzung anderer Richtlinien der Europ ischen Union dienen Pr fbeschreibung Emission und St rfestigkeit Pr fstandards EN 301489 1 V 1 8 1 EN 301489 3 V 1 4 1 Diese Konformit tserkl rung wird gem Artikel 10 Abs 1
14. Ger t wieder auf die eingestellte Leistung auf geladen ist Sowohl korrekte Ladung als auch erneute Blitzbereitschaft werden dadurch angezeigt Die Abblitz kontrolle gibt die Sicherheit dass bei Verwendung mehr erer Blitzger te die Blitzlampen gez ndet haben HENSEL VISIT GmbH amp Co KG 19 Bedienungsanleitung Integra Plus Kompaktblitzgerat Tagesblitzzahler 3 Zum Ablesen des Tagesblitzzahlers die Audiotaste 3 f r UDIO ca 3 Sekunden dr cken Am LED Display 14 erscheint 14 die Anzahl der ausgel sten Blitze als 2 stellige Zahl An gezeigt werden die Hunderter und die Zehner Stelle die letzte Stelle Einer wird abgeschnitten siehe Beispiel e Anzeige 05 gt Anzahl ausgel ster Blitze zwischen 50 und 59 e Anzeige 15 gt Anzahl ausgel ster Blitze zwischen 150 und 159 Der Tagesblitzz hler wird durch Dr cken des Drehreglers 13 13 wieder auf NULL zur ckgesetzt Durch nochmaliges Dr cken der Audiotaste wird das Men wieder verlassen Nach 5 Sekunden wird das Men auch automatisch ver lassen 9 Funkfernbedienung Strobe Wizard Plus Anwendung Der Funksender Strobe Wizard Plus dient zur Blitzausl sung sowie zur Blitzleistungsverstellung und Einstelllicht FULL AUS PROP Schaltung f r Hensel Blitzger te mit eingebautem Empf nger per Funksignal Die Funkfern bedienung darf zu keinem anderen Zweck verwendet Strobe Wizard Plus werden speziell nicht zur Steuerung anderer elektroni SENGEN EHS 200 s
15. Kompaktblitzger te d rfen nur an einem Stromnetz mit intaktem Schutzleiter angeschlossen werden HENSEL VISIT GmbH amp Co KG Bedienungsanleitung Integra Plus Kompaktblitzgerat Kabel m glichst nicht am Studioboden verlegen um Besch digungen auszuschlie en Ist eine Boden verlegung nicht zu vermeiden ist darauf zu achten dass die Kabel nicht durch Fahrzeuge Leitern etc besch digt werden Besch digte Kabel und Geh use sofort vom Kundendienst ersetzen lassen Keine Gegenst nde in L ftungsschlitze oder Synchron buchsen stecken L ftungsschlitze des Kompaktger tes w hrend des Betriebes freihalten und f r ausreich ende Luftzufuhr sorgen Keine Gegenst nde Werk zeuge Kaffeetassen etc auf dem Ger t ablegen Blitzanlagen nicht in explosionsgef hrdeten Umge bungen verwenden Brennbare Materialien wie Dekora tionsstoffe papiere u nicht in unmittelbarer Umge bung der Kompaktblitzger te lagern um Brandgefahr zu vermeiden Sch tzen Sie die Ger te unbedingt vor Feuchtigkeit auch Schnee und Eis Tropf und Spritzwasser W hlen Sie sichere Standorte f r die Aufstellung der Ger te und achten Sie darauf dass die Ger te nicht in Pools oder Gew sser fallen k nnen Verlegen Sie Kabel niemals direkt an oder gar in Pools oder Gew ssern Keine Zubeh rteile anderer Hersteller anschlie en auch wenn diese gleich oder hnlich aussehen Kompaktblitzger te an Scheren oder Decken h ng e
16. Low Voltage Directive Standards EN 60065 2002 A1 2006 Cor 2007 A11 2008 EN 60598 1 2008 A11 2009 EN 60598 2 9 1989 A1 1994 EN 50371 2002 This declaration of conformity is made by the above mentioned manufacturer according to article 10 paragraph 1 of the Governing EU directives 2006 95 EC referring to electrical items for usage within specified voltage limits This declaration of conformity is the result of testing samples of the products submitted in accordance with the provisions of the relevant specific standards Date April 27 2010 ana ing Director HENSEL Studiotechnik GmbH amp Co KG Notizen Notes Notizen Notes Notizen Notes HENSEL WWW HENSEL DE
17. Now attach the accessory part even and precisely to the unit Please do not tilt By releasing the lever the holding clamps will enclose the accessory part completely For loosening the accessory please hold tight the accessory part Attention it could be hot and tension the lever again as described above In any case please make sure not to damage either the flash tube or the modeling lamp danger Assembly of umbrellas and Softstar An umbrella holder is integrated in the tilting head that allows for the connections of various umbrellas by using a strong gripping spring mechanism The umbrella is inserted into the hole above the fixing bracket 20 and fastened by tightening the clamping screw 18 HENSEL VISIT GmbH amp Co KG 39 User manual Integra Plus Compact flash unit 40 Mains connection Attention Before connecting the compact flash unit to the mains outlet make sure that the mains voltage matches the information given on the type label of the compact flash The type label can be found on the bottom of the appliance The Integra Plus series comes with bi voltage technology ie the compact flash adjusts itself for different main voltages 110 V and 230 V The provided power cable has to be led through the handle then attached to the mains socket 10 and connected to the mains outlet Use the cable fixation 15 for allowing unhindered tilting of the unit Compact flashes must only be connected to mai
18. Zubeh r Schutzglocken Art Nr 9454638 klar unbeschichtet Art Nr 9454637 klar einfach beschichtet Art Nr 9454639 matt unbeschichtet Blitzr hre steckbar einfach beschichtet Art Nr 9450401 Integra 250 bzw 500 Plus Art Nr 9450420 Integra 1000 Plus Reflektoren und Softboxen mit EH Anschluss 10 cm Schirme Funkfernbedienung Strobe Wizard Plus f r Funkfernausl sung und Blitzsteuerung Sender Strobe Wizard Plus Art Nr 3950 oder Sender freemask Art Nr 3955 Art Nr 1316620 Power Max L 230 V tragbare Stromver sorgung f r aktuelle Hensel Kompaktblitzger te HENSEL VISIT GmbH amp Co KG 27 Bedienungsanleitung Integra Plus Kompaktblitzgerat 28 13 Kundendienst Werkskundendienst HENSEL VISIT GmbH amp Co KG GERMANY Serviceabteilung Robert Bunsen Str 3 D 97076 W rzburg Tel 0931 27881 0 Fax 0931 27881 50 Internet http www hensel de E Mail info hensel de Autorisierte Kundendienste im Inland Andreas Jakob Blitzservice Chapeaurougeweg 13 Tel D 20535 Hamburg Fax J rgen Skaletz Elektronik Service Im langen Muhlenfeld 7 Tel D 31303 Burgdorf Fax Arne Pohl Elektronik Service Sandbergstra e 29 Tel D 51147 K ln Wahn Fax Kersten Heilmann Reparaturservice Friedhofstr 66 Tel D 85716 Unterschlei heim Fax Kundendienste im Ausland finden Sie auf www hensel de 040 219 847 13 040 219 847 14 0511 799 722 0511 799 484 0220
19. age 30 HENSEL VISIT GmbH amp Co KG 5 Bedienungsanleitung Integra Plus Kompaktblitzgerat 1 Einleitung Liebe Fotografin lieber Fotograf mit dem Kauf einer Hensel Blitzanlage haben Sie eine hochwertige und leistungsf hige Ausstattung erworben Damit Sie viele Jahre erfolgreich und produktiv mit diesem Ger t arbeiten k nnen m chten wir Ihnen nachfolgend einige Hinweise zum Gebrauch geben Nur durch die notwendige Beachtung unserer Informa tionen sichern Sie sich Garantieleistungen vermeiden Sie Sch den und verl ngern die Nutzungsdauer des Ger tes Die Firma Hensel Visit hat sich alle M he gegeben unter Einbeziehung und Beachtung aller g ltigen Vorschriften ein sicheres und qualitativ hochwertiges Ger t zu fertigen Strenge Qualit tskontrollen stellen auch bei Gro serien unseren Qualit tsma stab sicher Bitte tun Sie das Ihre hinzu und behandeln Sie die Ger te mit der notwendigen Sorgfalt Sollten Sie zur Nutzung Fragen haben stehen wir Ihnen jederzeit gern zur Verf gung Wir w nschen Ihnen viel Erfolg und gut Licht HENSEL VISIT GmbH amp Co KG Bedienungsanleitung Stand 09 2013 Technische nderungen und Druckfehler vorbehalten Die angegebenen Werte sind Richtwerte und im rechtlichen Sinne nicht als zugesicherte Eigenschaften zu verstehen Die Werte k nnen durch Bauelementetoleranzen schwanken 6 HENSEL VISIT GmbH amp Co KG Bedienungsanleitung Integra Plus Kom
20. alb der daf r vorgesehenen Schiene neu zu justieren Dazu wird Schraube 17 mittels eines Kreuzschlitzschraubenziehers gel st und nach der end g ltigen Positionierung des Neigers wieder festgezogen HENSEL VISIT GmbH amp Co KG 18 Bedienungsanleitung Integra Plus Kompaktblitzgerat Befestigung der Schutzglocke Achtung Befestigung oder Demontage der Schutz glocke darf nur erfolgen wenn das Kompaktgerat ausgeschaltet und vom Stromnetz getrennt ist Es ist unbedingt darauf zu achten dass Blitzrohre und Einstelllicht unbesch digt bleiben Die Schutzglocke wird an den drei vormontierten Federn befestigt Dabei die Glocke zun chst leicht verkanten und in eine der drei Federn einsetzen Dann die Glocke mit leichtem Druck in die anderen zwei Federn hineindr cken bis sie sicher eingerastet ist Zum Demontieren der Schutzglocke diese leicht verkan ten so dass sie sich aus zwei Befestigungsfedern l st Dann unter leichtem Zug die Glocke gerade aus der dritten Feder l sen und abziehen Anschluss von Zubeh r An Integra Plus Kompaktger te k nnen alle Hensel Reflektoren und Softboxen der EH Serie Anschluss Durchmesser 10 cm mit dem entsprechenden Zubeh r sowie Schirme und der Softstar angeschlossen werden Reflektorschnellwechselmechanik Zum Befestigen von Reflektoren oder Softboxen wer den zun chst die Haltekrallen in die ge ffnete Position gebracht Dazu den Reflektorhebel gegen die Federkraft bis zum
21. ashing of these units when using the freemask application The freemask compact flash units used for lighting the mask have to be set on channels F1 or F2 or F3 The slave of the freemask compact flash units must be turned off to avoid their triggering by the first flash group The slaves of all other flash units can be turned on Exclusion Speed Max They offer too short recycling times The freemask transmitter can be set to channel ALL Channel selection for several work stations If several separate work stations are set up within the range of the radio remote control the following configurations can be selected matching channels have to be assigned to all flash units of both work groups and of the freemask transmitter e g C1 F1 for work station 1 and C2 F2 for work station 2 and C3 F3 for work station 3 Camera settings If your camera supports these settings use the following settings for the freemask application 1 Speed of picture series to fastest setting 2 Number of exposures to two This ensures the setting to highest picture frequency with two succeeding exposures depending on camera The transmitter will then trigger the flash group 1 C1 C2 and C3 for the set lighting and the flash group 2 F1 F2 and F3 for the mask lighting during the two camera exposures At present all cameras are supported with picture series speeds from 3 pictures per second to in theory 500 pictures per second The
22. bzw die Abk hlphase abzuwarten Eine besch digte Blitzr hre bedeutet Lebensgefahr da die hochspannungsf hrenden Elektroden ber hrt werden k nnen Das Kompaktblitzger t ist unverz g lich auszuschalten vom Stromnetz zu trennen Eine Wartezeit von mind 15 Minuten ist einzuhalten damit sich die Kondensatorspannung abbauen kann Die Integra Plus Ger te verf gen ber eine steckbare Blitzrohre die unter sorgf ltiger Beachtung der Sicherheitsvorschriften selbst gewechselt werden kann Austausch siehe Kapitel 10 Wartung Montage Bei Montage an Deckenschienen oder Scheren muss das Kompaktger t gegen Herunterfallen gesichert werden Dies geschieht durch eine Sicherungsschraube nicht im Lieferumfang enthalten die in das daf r vorgesehene Gewinde am Hensel Schwenkneiger eingeschraubt wer den muss Es ist jedoch wegen geltender Sicherheitsvor schriften eine Zweitsicherung durch ein Stahlseil not wendig Dieses kann von der Firma Hensel Visit unter der Art Nr 769 bezogen werden Das Stahlseil ist durch den Ger tegriff zu f hren und durch eine geeignete Ose an der Abh ngung zu sichern HENSEL VISIT GmbH amp Co KG 13 Bedienungsanleitung Integra Plus Kompaktblitzgerat ek N oO ek leo 14 Warmeentwicklung Jedes Kompaktblitzgerat gibt durch das Einstelllicht und das Blitzlicht W rme ab Diese W rme kann Ger teteile erheblich aufheizen so dass Verbrennungsgefahr beim Ber hren entsteht
23. cher Ger te oder Maschinen Lieferumfang Zum Lieferumfang von Sender Art Nr 3950 bzw 3955 bzw Sender und Empf nger Set Art Nr 3952 geh rt jeweils ein Synchronkabel mit 2 5 mm Synchronstecker Sicherheitshinweis Jede Ver nderung an der Funkfernbedienung ist unbe dingt zu unterlassen Das Geh use des Senders ist spritz wassergesch tzt jedoch nicht wasserdicht Eine Verwen dung im Regen ist nicht zu empfehlen da im Lauf der Zeit 20 HENSEL VISIT GmbH amp Co KG IN Is lo A Q 21a 21b Bedienungsanleitung Integra Plus Kompaktblitzgerat Wasser in das Geh use eindringen und die Elektronik be schadigen kann Kanalwahl am Kompaktblitzgerat Der eingebaute Empfanger wird durch Betatigung der RC Taste 2 eingeschaltet Die Kanalwahl kann nach einmaligem Klicken auf den Blitzenergieregler 13 vorgenommen werden durch Wahl eines Kanals von 1 3 Uber die LED Anzeige 14 Nach der entsprechenden Kanalwahl erfolgt nach ca 3 Sekunden Wartezeit oder durch Betatigen des Reglers 13 wieder der Wechsel zur Blitzenergie Anzeige Inbetriebnahme des Senders und Kanalwahl Der Funksender verf gt nicht ber einen Einschalter Der Sender ist mit der Kamera zu verbinden Dies geschieht entweder durch Aufstecken des Senders und sorgf ltiges Festschrauben mittels Feststellschraube 25 auf den Blitzschuh oder durch Verbinden der Kamera mit dem mitgelieferten Synchronkabel ber den Synchron kontakt Synchronbuch
24. e compact flash unit must be separately disposed of and recycled Worn out and broken appliances must be disposed of by electronics recycling 12 Accessories Glass Domes Code No 9454638 clear uncoated Code No 9454637 clear single coated Code No 9454639 frosted uncoated Flash tube user replaceable Code No 9450401 U Tube single coated series 250 500 Code No 9450420 U Tube single coated series 1000 Reflectors and Softboxes with small accessory adapter diameter EH 10 cm HENSEL VISIT GmbH amp Co KG User manual Integra Plus Compact flash unit Umbrellas Strobe Wizard Plus for radio flash triggering and radio control Transmitter Strobe Wizard Plus Code No 3950 freemask transmitter Code No 3955 Code no 1316620 Power Max L 230 V battery power supply for current Hensel compact flash units 13 Customer service Works customer service HENSEL VISIT GmbH amp Co KG GERMANY service department Robert Bunsen Str 3 D 97076 W rzburg Phone 49 0 931 27881 0 Fax 49 0 931 27881 50 Internet www hensel de E Mail info hensel de International service addresses are available at www hensel de HENSEL VISIT GmbH amp Co KG 51 Declaration of Conformity EXPERT INTEGRA Pro Plus doc Declaration of Conformity for Radio and Telecommunication Terminal Equipment Electromagnetic Compatibility and Safety Manufacturer HENSEL Studiotechnik GmbH amp Co KG Robert Bunsen St
25. ek troden ber hrt werden In diesem Fall ist f r die Ent fernung der besch digten Blitzr hre eine voll isolierte Zange zu benutzen Zun chst den Z nddraht von dem Anschlussstift der Z n dung abwickeln Dann die Blitzr hre vorsichtig aus dem Steckkontakt herausziehen und durch eine neue siehe unten ersetzen Anschlie end den Z nddraht wieder um den Anschlussstift wickeln Es ist unbedingt darauf zu achten dass nur die vor geschriebene Blitzr hre eingesetzt wird Blitzr hre einfach beschichtet steckbar Integra 250 500 Plus Art Nr 9450401 oder Integra 1000 Plus Art Nr 9450420 HENSEL VISIT GmbH amp Co KG Bedienungsanleitung Integra Plus Kompaktblitzgerat Turnusm ige berpr fung Die nationalen Sicherheitsvorschriften verlangen eine in tervallm ige berpr fung und Wartung elektrischer Anlagen und Ger te Kompaktblitzger te und Zubeh r m ssen regelm ig auf ihre Betriebssicherheit berpr ft werden Eine j hrliche Durchsicht der Ger te dient der Sicherheit der Benutzer und erh lt den Wert der Anlage R cksendung an Kundendienst Um einen optimalen Schutz der Ger te beim Versand zu gew hrleisten sollte je Ger tetyp eine Originalverpack ung aufbewahrt werden 11 Entsorgung ay Das Verpackungsmaterial des Kompaktblitzgerates ist zu EO trennen und der Wiederverwertung zuzuf hren Ausge LA diente und defekte Ger te m ssen dem Elektronikre cycling zugef hrt werden 12
26. et on the carriage HENSEL VISIT GmbH amp Co KG 37 User manual Integra Plus Compact flash unit EEE E IS 38 Heating Due to the modeling lamp and flashlight each compact flash unit emits heat This can heat the parts of the unit up to a dangerous level Therefore make sure that the flash unit is located far enough from inflammable props to avoid inflaming them Take care for sufficient air supply and make sure that ventilation slots of compact flash units are kept free Do not operate flash units unattended The modeling light should never be used for lighting up the studio but only as assistance when focusing or determining the light guiding and shadow details of the flash Acclimatizing When moving the flash unit from one climatic zone to the next the appliance should stand in the room in which it will be operated for some time before starting it up This prevents possible surface leakage currents due to con densing water Positioning Integra Plus compact flash units come with a tilting head The unit can be attached to a stand or pantograph by using one of the two holes and safely secured by fastening the locking screw 19 The angle of inclination can be adjusted using the fixing bracket 20 In the hole 16 above the fixing bracket an umbrella can be inserted and fastened using the clamping screw 18 To hold even heavy loads it is advisable to find a new optimal position for the tilting head within the glidin
27. f Depending on the mains circuit only the specified modeling lamps should be used see below When changing the modeling lamp please note that it will be secured by the correct value Use only halogen lamps as modeling light with the maximal light output specified as follows 300W G6 35 115V Code 1280 or 300W G6 35 230V Code 128 resp HENSEL VISIT GmbH amp Co KG User manual Integra Plus Compact flash unit Make sure that the modeling lamp corresponds to the mains voltage Wait until the modeling lamp has cooled down and then remove the glass dome carefully from the unit by pulling it out of the spring mechanism see page 38 39 and moving it straight away without touching modeling lamp or flash tube danger Handle halogen lamp with care Pull out halogen lamp and replace the modeling lamp with a new one Avoid handling the modeling lamp with your bare hands to prevent contaminating the modeling lamp with the oil of your skin This would reduce the operational life of the modeling lamp Please use cotton gloves Replacement of flash tube All unit types of the Integra Plus series are fitted with a user replaceable flash tube For replacement of flash tube switch the unit off separate it from the mains outlet and wait for at least 15 minutes Then remove the glass dome from the head carefully by pulling it out of the spring mechanism see page 38 39 and moving it straight away from the head w
28. f the information given you secure your warranty prevent damage and prolong the life of the equipment Hensel Visit has taken great care to manufacture a secure and high quality flash system under inclusion and observance of all current regulations Strict quality controls secure our quality requirements even in mass production Please take your part in this and treat the equipment with due care your reward will consist of excellent pictures If you should have any questions on the use then feel free to ask us at any time We wish you success and good light HENSEL VISIT GmbH amp Co KG User manual date of revision 2013 09 Technical data are subject to change No guarantee for misprints The listed values are guide values and should not be understood as binding in a legal sense The values can differ due to tolerances in used components 30 HENSEL VISIT GmbH amp Co KG User manual Integra Plus Compact flash unit 2 Table of contents T HIrOdUclon see 30 2 Table edalea reta 31 3 General safety regulations 32 33 4 Standard delivery rss 34 5 Technical GEA 35 6 Overview of eela Le 36 Ekitea lagi BU aA 37 etzela rar 37 38 a eela ZING Sa 38 POSIHONINg E 38 Fixing of the glass dome rss 38 39 aleei debea 39 Mains eela ela 40 BREA aek 40 Overheating E 40 8 eez daua EAE 41 Synchronization Flash triggering 41 42 Flash power GORO ss 42 Flashireadine
29. g auf h chste Bildfrequenz mit zwei aufeinanderfolgenden Belichtungen gew hrleistet kameraabh ngig Der Sender wird dann bei den zwei Belichtungen der Kamera jeweils die Blitzgruppe 1 C1 C2 und C3 f r die Motivbeleuchtung und die Blitzgruppe 2 F1 F2 und F3 f r die Maskenbelichtung ausl sen Derzeit werden alle Kameras mit Seriengeschwindigkei ten ab 3 Bilder pro Sekunde bis theoretisch 500 Bilder pro Sekunde unterst tzt Der Sender stellt automatisch nach der Ausl sung unab h ngig von der tats chlichen Anzahl der Ausl sungen nach 200 ms auf Bildausl sung 1 zur ck Dadurch wird sichergestellt dass bei der freemask Anwendung immer die Motivbeleuchtung als erste und die Maskenbeleuch tung immer als zweite Aufnahme erfolgt 10 Wartung Integra Plus Kompaktblitzger te ben tigen nur wenig Wartung durch den Benutzer Um die elektrische Sicher heit zu gew hrleisten muss das Ger t regelm ig u er lich von Staub und Schmutz befreit werden Achtung Vor der Reinigung ist das Ger t vom Strom netz zu trennen Ger t nur trocken reinigen Instand haltung und Reparaturen d rfen nur vom autori sierten Kundendienst durchgef hrt werden Sicherung austauschen Sollte beim Durchbrennen der Schmelzsicherung 9 ein Austausch notwendig werden so darf dies nur bei ausge schaltetem und vom Stromnetz getrenntem Ger t erfol gen HENSEL VISIT GmbH amp Co KG Bedienungsanleitung Integra Plus Kompa
30. g rail For doing this unscrew the Philips screw 17 and slide the tilting head within the rail until the weight is balanced and finally tighten the screw Fixing of the glass dome Attention The glass dome should only be fixed or removed after having switched the unit off and unplugged from the mains outlet Please take care not to damage either the flash tube or the modeling lamp danger HENSEL VISIT GmbH amp Co KG User manual Integra Plus Compact flash unit The glass dome is fixed by means of the three pre mounted springs For doing this please tilt the glass dome slightly and insert it into one of the three springs Then press the glass dome gently into the other two springs until it has completely clicked in For removing the glass dome please tilt it slightly again so that it will slip out easily of the two fixing springs Then gently loose the glass dome from the remaining third spring and remove it from the fixing device Accessories All Hensel reflectors and Hensel softboxes of series EH adapter 10 cm accessories included may be attached to the Integra Plus compact flash also umbrellas and Softstars Assembly of reflectors and softboxes For fixing reflectors or softboxes to the compact flash unit please first of all open the holding clamps For doing this please tension the reflector lever laterally as far as it will go against the spring tension While doing this the holding clamps will open
31. he Spannung aufgeladen werden Dadurch sind Gefahrenquellen gegeben die sorgfaltig auszuschlieBen sind Neben den allgemeinen Regeln im Umgang mit elektrischen Ger ten sind deshalb Vorsichtsma nahmen zu treffen die nachfolgend beschrieben sind Lesen und befolgen Sie deshalb die Sicherheitshinweise siehe auch Kapitel Inbetriebnahme und die Bedienungsanleitung vor Inbetriebnahme des Ger tes Das vorliegende Kompaktblitzger t ist f r den Studioein satz des professionellen Fotografen bestimmt Die Auf gabe ist das Bereitstellen der elektrischen Energie zur Blitzlichterzeugung Das Ger t darf zu keinem anderen Zweck benutzt werden als oben beschrieben insbesondere nicht f r andere elektrische Anwendungen Da beim Betrieb von Halogenlampen und Blitzr hren Berstgefahr besteht d rfen alle Blitzger te nur mit der vorschriftsm ig montierten Hensel Schutzglocke betrieben werden Sie ist in verschiedenen Aus f hrungen erh ltlich Der Gebrauch der jeweiligen Schutzglocke ver ndert die Farbtemperatur e Der Kontakt mit der Kondensatorspannung ist lebens gef hrlich deshalb d rfen das Offnen des Geh uses und Reparaturen am Kompaktger t nur vom autorisier ten Kundendienst durchgef hrt werden e Integra Plus Kompaktblitzger te sind mit einer steck baren Blitzr hre ausgestattet Das Wechseln von Blitz r hre und Einstelllampe darf nur bei ausgeschaltetem vom Stromnetz getrenntem und entladenem Ger t er folgen e
32. htformers softboxes etc before use and turning on the unit Do not move compact flashes around while they are operating Turn the appliance off for each change of reflectors or to move the unit to another location Reflectors speedrings and other accessories heat up during longer operation To avoid injuries handle with isolating cloth while changing or wait until parts have cooled down A damaged flash tube is extremely dangerous because the electrically charged electrodes are exposed and could be touched Turn the unit off and disconnect it from any power supply before replacing the flash tube Wait at least 15 minutes before continuing the procedure and until any remaining condenser voltage has dissipated The EH Pro Mini Heads are equipped with a user replaceable flash tube In case of an exchange the safety regulations must be strictly adhered to Replacement see page 48 Maintenance Assembly When mounting to a ceiling system or a pantograph the suspended compact flash unit has to be doubly secured from falling down or dropping This is done by tightening the safety screw not included in the standard delivery into the thread of Hensel tilting head Due to the existing safety regulations it is however necessary to use a Safety rope Code No 769 for further security The safety rope has to be led through the handle of the compact flash unit and then secured by looping through the bracket on the pantograph or the eyel
33. ied correctly installed Hensel protection glass dome The glass dome is available in different versions The use of the glass dome changes the color temperature e Contact with the capacitor voltage is perilous and therefore opening of the case of Integra Plus compact flash units and repairs must only be made by authorized customer service e Integra Plus compact flash units are equipped with a user replaceable flash tube Exchange of flash tube and modeling lamp must only be performed with the appliance turned off unplugged from the mains and discharged e Compact flashes must only be used on supply lines mains with working protective conductor earth line HENSEL VISIT GmbH amp Co KG User manual Integra Plus Compact flash unit e Do not route cables across the studio floor if possible so that damage is excluded If routing across the studio floor cannot be omitted then it must be ensured that vehicles ladders etc do not damage cables Damaged cables and cases must be replaced immediately by customer service e Ventilation slots of compact flashes must be kept free during operation and sufficient air supply must be ensured Do not stick any objects into ventilation slots or synchronization sockets Do not deposit any objects tools coffee cups etc on the flash unit e Flash systems must not be used in environments with explosion hazard Flammable materials like furnishing fabrics paper etc must not be s
34. inen Testblitz schnell auf den aktuellen Wert abzubauen Bet tigung von Schalter 6 Einstelllicht Die Betriebsart des Einstelllichtes wird ber die Schalter 11 und 12 gew hlt Wird Taste 11 FULL eingeschaltet gibt das Einstelllicht seine maximale Leistung ab Wird Taste 12 PROP eingeschaltet ist die Helligkeit des Einstelllichtes proportional zur gew hlten Blitzenergie Wird die maximale Blitzleistung reduziert wird die maxi male Leistung des Einstelllichtes proportional gedimmt Der jeweils aktive Modus wird durch das Aufleuchten der jeweiligen Kontroll LED angezeigt Ist kein Modus akti viert ist das Einstelllicht ausgeschaltet Auto Dim Funktion Diese Funktion dient der Verl ngerung der Lebensdauer der Einstelllampe Wird f r das Einstelllicht die Option FULL gew hlt oder PROP Modus zwischen 10 0 und 9 1 siehe LED Display dann wird nach einer Dauer von 35 Minuten diese Leistungseinstellung um eine Blende ge dimmt Default Einstellung ab Werk sofern in dieser Zeit nicht mit dem Ger t gearbeitet wird Bet tigung einer be liebigen Taste setzt das Einstelllicht wieder auf den unge dimmten Wert zur ck Bei Bedarf kann die Betriebsdauer durch 2 maliges Dr cken der Taste 13 auf einen neuen Wert zwischen 5 95 Minuten eingestellt werden der am LED Display 14 angezeigt wird Flash Check Ist diese Betriebsart aktiviert verl scht die Einstelllampe sofort nach dem Abblitzen und leuchtet erst wieder auf wenn das
35. ithout touching modeling lamp or flash tube danger Handle flash tube with care Avoid handling the flash tube with your bare hands to prevent contaminating the flash tube with the oil of your skin This would reduce the operational life of the flash tube Please use cotton gloves Should the glass body of the flash tube be broken do not touch the electrodes under any circumstances In this case use a fully insulated pair of pliers to remove the damaged flash tube First unwind the ignition cable from the connection pin or the ignition Then pull out flash tube and replace it with a new one Finally connect the ignition cable HENSEL VISIT GmbH amp Co KG 49 User manual Integra Plus Compact flash unit LA 50 You must make sure that the appropriate flash tube is used Please order from Hensel Visit Flash tube user replaceable single coated Integra 250 500 plus Code No 9450401 or Integra 1000 Plus Code No 9450420 Regular inspection National safety regulations require regular inspection and maintenance of electrical systems and appliances Compact flash units and accessories must be checked regularly for safe operation Yearly inspection of the appliances serves the safety of the user and protects your investment in the system Return to customer service To achieve a maximum protection of the unit sending it in for service the original packaging should be kept 11 Disposal Packaging of th
36. ke any liability for possible damage to cameras triggering flashes Please contact the camera manufacturer before using an unusual camera Synchronization by slave The built in slave 8 can trigger the compact flash unit Triggering is then effected by an incoming flash which was emitted by another flashlight This mode of operation is switched on using switch 5 and displayed by the orange light of the SLAVE ON indicator The slave is an impulse photocell It can only operate when the triggering flash has a higher f stop than the ambient light Please be aware that the ambient light that strikes the slave may never be too strong If this cannot be avoided please switch the slave off by pressing switch 5 and release the flash by cable or by radio signal synchronization by radio control system All units of the Integra Plus series are provided with the built in radio receiver Strobe Wizard Plus and a freemask function With the respective transmitter available as accessory flashes can be triggered and in addition features for flash power and modeling light adjustment are offered The built in receiver has to be activated by pressing the RC switch 2 The radio transmitter is attached to the camera using the synchronization cable or by mounting it onto the hot shoe of the camera Three channels can be selected HENSEL VISIT GmbH amp Co KG 41 User manual Integra Plus Compact flash unit 6 EST READY FC AUDIO
37. ktblitzgerat Achtung Keinesfalls d rfen Sicherungen geflickt oder berbr ckt werden Beim Erneuern der Sicherungen ist unbedingt darauf zu achten dass ausschlie lich Ersatzsicherungen mit dem unten spezifizierten Wert und Ansprechverhalten flink eingesetzt werden Schmelzsicherungen f r Betrieb mit 300W Halogenlampe 4 AF Nur Sicherungen mit gro em Schaltverm gen nach EN 60127 2 1 bzw IEC 127 2 1 verwenden Falsche Ab sicherung beinhaltet erh hte Berstgefahr der Halo genlampe beim Durchbrennen der Gl hwendel Einstelllampe austauschen Achtung Schalten Sie das Ger t vor dem Aus wechseln der Einstelllampe aus trennen Sie es vom Stromnetz und halten Sie eine Wartezeit von mindes tens 15 Minuten ein damit sich die Kondensator spannung abbauen kann In Abh ngigkeit von Netzspannung und Ger tetyp darf nur die vorgeschriebene Einstelllampe verwendet werden Beim Austausch der Einstelllampe ist darauf zu achten dass diese entsprechend ihrer Leistung vorschriftsm ig abgesichert ist Als Einstelllicht d rfen maximal verwendet werden 300W G6 35 115V Art Nr 1280 bzw 300W G6 35 230V Art Nr 128 Die Einstelllampe ist entsprechend der Netzspannung ein zusetzen Vor dem Auswechseln muss die Abk hlung der Einstell lampe abgewartet werden Wie auf Seite 15 beschrieben wird zun chst die Schutz glocke vorsichtig abgenommen Blitzr hre und Einstelllicht d rfen dabei
38. n bis zu drei verschiede nen getrennten Arbeitspl tzen verwenden Kanalwahl f r einen Arbeitsplatz F r die freemask Anwendung stellen Sie bitte zum automatischen synchronen Ausl sen alle Blitzger te f r die Motivbeleuchtung auf C Kan le ein Die freemask Kompaktblitzger te f r die Maskenbeleuchtung m ssen auf die Kan le Fi oder F2 oder F3 eingestellt werden Die Fotozelle Slave der freemask Kompaktblitzger te muss ausgeschaltet sein um das Ausl sen durch die erste Blitzgruppe zu verhindern Die Fotozellen aller anderen Blitzger te k nnen eingeschaltet sein Der freemask Transmitter wird f r die Blitzausl sung auf den ALL Kanal gesetzt Kanalwahl f r mehrere Arbeitspl tze Wenn mehrere getrennte Arbeitspl tze eingerichtet wer den sollen die sich innerhalb der Funkreichweite befin den k nnen folgende Konfigurationen eingestellt werden Allen Blitzger ten der beiden Arbeitsgruppen sowie dem freemask Transmitter m ssen bereinstimmende Kan le zugewiesen werden z B C1 F1 f r Arbeitsplatz 1 und C2 F2 f r Arbeitsplatz 2 und C3 F3 f r Arbeitsplatz 3 HENSEL VISIT GmbH amp Co KG 23 KO Bedienungsanleitung Integra Plus Kompaktblitzger t 24 Kameraeinstellungen Fur die freemask Anwendung stellen Sie wenn kamera seitig mdglich folgende Einstellungen ein 1 Serienbildgeschwindigkeit auf schnellste Geschwindig keit 2 Anzahl der Belichtungen auf zwei Damit ist die Einstellun
39. nal to the selected flash power When the flash power is reduced the modeling light output will HENSEL VISIT GmbH amp Co KG 3 UDIO 14 User manual Integra Plus Compact flash unit be reduced by the same increments The selected operation mode for the modeling lamp is indicated by the respective ON indicator The modeling lamp is switched OFF when no ON indicator lights up Dim mode The dim mode is intended to prolong the life span of the modeling lamp If the modeling lamp level is adjusted to FULL or to PROP between 10 0 and 9 1 the output is dimmed automatically by approximately 1 f stop after having stopped working with the flash unit for longer than 35 minutes default value Pressing any button you like switches the modeling light to the previously adjusted un dimmed level If required this default value can be changed by entering a value from 5 minutes up to 95 minutes For this purpose press button 13 twice and enter the new value shown on display 14 Wait for 3 seconds and the display changes to the flash power setting Flash Check If this mode is switched on by pressing the FC button 4 the modeling lamp is turned off after a flash and will turn on after recharging to the adjusted power level This shows correct charge as well as readiness to flash The flash check mode guarantees that the flash heads have triggered when more than one flash unit is used Flash counter The data is read out of the flash co
40. nd sind gegen Herabfallen doppelt zu sichern Nicht aus kurzer Distanz unter 5 m in die Augen blitzen da dies zu Augensch den f hren kann Nicht direkt in den Blitzreflektor blicken Geschlossene R ume regelm ig l ften um unzul s sige Ozonkonzentrationen die durch die Verwendung starker Blitzger te entstehen k nnen zu vermeiden Bei Arbeiten im Studio die eine hohe Staubentwick lung verursachen sind nicht im Betrieb befindliche Ger te durch einen geeigneten Staubschutz abzu decken HENSEL VISIT GmbH amp Co KG 9 Bedienungsanleitung Integra Plus Kompaktblitzgerat 4 Lieferumfang Zum Standardlieferumfang aller Integra Plus Ger te ge h ren e Blitzr hre einfach beschichtet steckbar e Schutzglocke klar unbeschichtet e Schwenkneiger kombiniert mit Schirmhalter e Kabelsatz Netz und Synchronkabel e Transportschutzkappe Der Funksender ist nicht im Standard Lieferumfang ent halten und muss separat bestellt werden Art 3950 oder 3955 10 HENSEL VISIT GmbH amp Co KG Bedienungsanleitung Integra Plus Kompaktblitzgerat 5 Technische Daten Gerateserie Integra Plus Geratetyp 250 500 1000 Messung bei 230 V 50 Hz Nennenergie 250 J 500 J 1000 J Leitblende 100 ASA t 1 60 45 8 10 64 8 10 90 9 10 1m Abstand 2m 12 Reflektor 22 8 10 32 8 10 45 9 10 Abbrennzeit in Sek t 0 5 1 2 380 1 1 390 1 1 680 Ladezeit in Sek 10
41. nd ausge tauscht werden Beim Wiedereinsetzen ist auf die Polung zu achten Der Pluspol ist auf der Seite der Taste Power 1a Down 21a Technische Daten Sender Typ Strobe freemask Wizard Plus Artikel Nr 3950 3955 Synchronanschluss 2 5 mm Klinke Mono Sync Spannung Sync Strom 3V lt 1mA f r 5 us Kan le 3 ber Schiebeschalter Min Verschlusszeit 1 250 s Ma eincm BxTxH 5 5 x 6 3 x 4 8 Gewicht komplett 53 g Batterie Typ 1 x 28L 6V Batterielebensdauer 1 bis 2 Jahre Reichweite gt 40 m bei freier Sicht Frequenz 433 92 MHz Das System erf llt die Forderungen nach ETSI EN300220 und FCC 15 231 22 HENSEL VISIT GmbH amp Co KG freemask Sender Art 3955 Bedienungsanleitung Integra Plus Kompaktblitzgerat freemask Kanalwahl Als Zusatzfunktion k nnen bei der Kanalwahl einmaliges Klicken auf den Blitzenergieregler 13 neben den Kan len C1 C2 und C3 zus tzlich die Kan le F1 F2 und F3 eingestellt werden Bei der Verwendung der Kompaktblitzger te f r die normale Motivausleuchtung mit den Kan len C1 C2 und C3 k nnen Sie wie gewohnt neben der synchronen Ausl sung auch die Blitzenergie und das Einstelllicht vom Funksender aus regeln F r die freemask Anwendung als zweite Blitzgruppe k n nen Sie die Blitzenergie und das Einstelllicht nicht vom Sender aus schalten Die Kan le F1 F2 und F3 k nnen Sie nur zur Unterscheidung vo
42. nicht ber hrt werden Gefahr Beim Hantieren mit einer freiliegenden Halogenlampe ist u erste Vorsicht geboten O HENSEL VISIT GmbH amp Co KG 25 Bedienungsanleitung Integra Plus Kompaktblitzgerat 26 Zum Austausch die Halogenlampe vorsichtig aus dem Steckkontakt herausziehen und durch eine neue Halogen lampe siehe oben ersetzen Vermeiden Sie das Anfassen der Lampe mit bloBen Handen um das Lampenglas nicht mit Hautfett zu verunreinigen das wurde deren Lebensdauer herab setzen Verwenden Sie Baumwollhandschuhe Blitzrohre austauschen Alle Ger te der Integra Plus Serie verf gen Uber eine steckbare Blitzr hre Im Falle eines Defektes kann diese durch den Benutzer selbst ausgetauscht werden Vor dem Auswechseln der Blitzr hre Ger t ausschal ten vom Stromnetz trennen und eine Wartezeit von mindestens 15 Minuten einhalten Anschlie end wie auf Seite 15 beschrieben vorsichtig die Schutzglocke abnehmen Blitzr hre und Einstelllicht d rfen dabei nicht ber hrt werden Gefahr Vermeiden Sie das Anfassen der neuen Blitzr hre mit blo en H nden um die Blitzr hre nicht mit Hautfett zu verunreinigen das w rde die Lebensdauer der Blitz r hre herabsetzen Verwenden Sie Baumwollhand schuhe Beim Hantieren mit einer freiliegenden Blitzr hre ist u erste Vorsicht geboten Achtung Sollte der Glask rper der Blitzr hre zerbrochen sein d rfen beim Auswechseln auf keinen Fall die El
43. ns outlets with ground connection Fuses Outlets in the building Minimum requirement 10 A fuse outlets Fuses of the compact flash unit The fuse 9 is a general fuse for the compact flash unit and the modeling lamp All units of the Integra Plus series bi voltage technology come with a fuse 4 A fast 4 AF 5x20 mm The specification of the fuses mentioned above is valid for operation with modeling light 300 W halogen For more information please refer to page 48 49 Replacement of fuses Overheating All Integra Plus units are equipped with a fan to avoid overheating with fast flash sequences which could cause damage to the flash tube and the compact flash unit Nevertheless if overheating occurs the error lt E1 gt is displayed on the LED 14 After a break for cooling down the appliance is ready again for operation HENSEL VISIT GmbH amp Co KG T YNC 100 5 LAVE JN O User manual Integra Plus Compact flash unit 8 Operation Synchronization Flash triggering Synchronization by cable The compact flash unit is connected to synchronization socket 7 to the camera using a synchronization cable with 6 3 mm phone jack The synchronization circuit is made up of state of the art semiconductor technology and enables secure triggering of the flash even with older cameras with mechanical contacts Due to the many different electronic circuits in cameras for controlling synchronization we cannot ta
44. onisation k nnen wir jedoch keine Haftung f r etwaige Sch den an der blitzausl senden Kamera ber nehmen Vor der Verwendung einer nicht markt blichen Kamera sollte deshalb der Kamerahersteller kontaktiert werden Synchronisation ber Fotozelle Das Kompaktblitzger t kann auch ber die eingebaute Fotozelle 8 ausgel st werden Das Ausl sen erfolgt dann durch das Auftreffen eines Blitzes welcher durch ein anderes Ger t abgegeben wurde Diese Betriebsart wird durch Bet tigung des Schalters SLAVE zugeschaltet und wird signalisiert durch das gelbe Licht der dar berliegenden orange leuchtenden LED Kontrolllampe Die Fotozelle ist als Impulsfotozelle ausgelegt Sie kann deshalb nur funktionieren wenn der auftreffende Blitz st rker im Blendenwert ist als das Umgebungslicht Es ist deshalb darauf zu achten dass kein zu starkes Fremdlicht auf die Fotozelle f llt Wenn dies nicht zu vermeiden ist muss die Fotozelle mittels Schalter 5 abgeschaltet und der Blitz ber Kabel oder Funkfernbedienung ausgel st werden HENSEL VISIT GmbH amp Co KG 17 Bedienungsanleitung Integra Plus Kompaktblitzgerat DN O 6 EST 3 4 6 READY FC AUDIO 18 Synchronisation Funkfernbedienung Die Integra Plus Ger te verf gen ber einen eingebauten Empf nger Strobe Wizard Plus und ber freemask Mit dem als Zubeh r erh ltlichen jeweiligen Sender k nnen Blitze ausgel st und zus tzlich Blitz und Einstelllich
45. paktblitzgerat 2 Inhaltsverzeichnis Te Einleitung AAE 6 GS ala AL diela E 7 3 Allgemeine Sicherheitsbestimmungen 8 9 A Lieferumlang a aa ein 10 5 Technische Daten a 11 6 bersicht der Bedienelemente 12 7 aleluia elebe 13 SicherheitShinweiSe 0cceeceeceeceeeeeeeeeeees 13 14 Akklimatisierung E 14 Aufstellung EEA 14 15 Befestigung der Schutzglocke 00 15 Anschluss von Zubeh r sees 15 16 ATZ dz ezea 16 ALA aa Aue 16 WIS FZ E 16 8 Sie G aA EAEE 17 Synchronisation Blitzausl sung 17 18 Leistungsregelung rrura 18 EI geldi derala AK 18 APB SYSIEmN an eier 19 Einstellen za ee 19 la aal geala d 20 9 Funkfernbedienung erruz 20 Strobe Wizard BIOS 20 22 freemask eisien s Be eg ie a 23 24 10 NVR dari 24 Sicherungen austauschen aaa 24 25 Einstelllampe austauschen 25 26 Blitzr hre austauschen PIERRE III iee artaz 26 Turnusm ige berpr fung 27 R cksendung an Kundendienst 27 agai deia ate RR 27 12 LUDO dA 27 13 K ndendienst 2er 28 EG Konformit tserkl rung 44444 29 HENSEL VISIT GmbH amp Co KG 7 Bedienungsanleitung Integra Plus Kompaktblitzgerat Bestimmungs gemaBer Gebrauch Nicht bestimmungs gemaBer Gebrauch 3 Allgemeine Sicherheitsbestimmungen Kompaktblitzgerate speichern Energie in Kondensatoren die auf ho
46. r 3 97076 W rzburg Germany Owner of Certification HENSEL Studiotechnik GmbH amp Co KG Robert Bunsen Str 3 97076 Wurzburg Germany Test Report of April 27 2010 Product EXPERT Pro 250 Plus INTEGRA Pro 250 Plus Integra 250 Plus EXPERT Pro 500 Plus INTEGRA Pro 500 Plus Integra 500 Plus EXPERT Pro 1000 Plus INTEGRA Pro 1000 Plus Integra 1000 Plus Description Radio and Telecommunication Terminal Equipment Standards EN 300220 2 V 2 1 2 This declaration of conformity is made by the above mentioned manufacturer according to article 3 of the governing EU directives R amp TTE1999 5 EC referring to Radio and Telecommunication Terminal Equipment for bringing the statutory instruments of the Member States into lines with each other This declaration does not make any statement according to requirements of other provisions concerning the electromagnetic compatibility and safety Description Emission and Interference Resistance Standards EN 301489 1 V 1 8 1 EN 301489 3 V 1 4 1 This declaration of conformity is made by the above mentioned manufacturer according to article 10 paragraph 1 of the governing EU directives 2004 108 EC referring to electromagnetic compatibility and safety for bringing the statutory instruments of the Member States into lines with each other This declaration does not make any statement according to requirements of other provisions concerning the electromagnetic compatibility and safety Description
47. se 24 Seitlich wird mittels Schie beschalter 22 einer der drei Arbeitskan le oder die Schalterstellung All gew hlt Blitzausl sung Entsprechend der Wahl des Arbeitskanals kann der Blitz nun selektiv ber die TEST Blitzausl setaste 23 oder durch Bet tigung der Kamera ausgel st werden Wurde am Sender AI eingestellt l sen alle Blitzger te aus unabh ngig von deren Kanaleinstellung Blitzleistungseinstellung und Einstelllicht Full Aus Prop Die Tasten 21a und 21b bieten zus tzlich die M glichkeit der Leistungsverstellung f r Hensel Blitzger te die mit ei nem entsprechenden Empf nger ausger stet sind Durch kurzzeitiges Dr cken wird die Leistung dabei in 1 10 Blendenschritten entweder erh ht oder reduziert Dr ckt man die Taste 21a l nger als 3 Sekunden so schaltet man das Einstelllicht zwischen FULL AUS und PROP Der Empf nger besitzt eine Interfacebuchse 30 zu Hensel Generatoren HENSEL VISIT GmbH amp Co KG 21 N N Bedienungsanleitung Integra Plus Kompaktblitzger t Wartung Die Hensel Funkfernbedienung Strobe Wizard Plus ist weitgehend wartungsfrei Durch den geringen Strom verbrauch ist beim Sender mit mindestens 1 2 Jahren Batterielebensdauer zu rechnen abh ngig von der Nutzung Die Batterie des Funksenders kann ersetzt 26 werden durch L sen der Schraube 26 auf der Unterseite des Ger tes Dabei wird die Elektronik zug nglich und die Batterie kann aus den Halteclipsen entfernt u
48. ss un 2er aaa aaas 42 APD EA eea E 42 Modeling lampe nenne 42 43 Flash COUNTS nee 43 44 9 Radio control AU 44 Strobe Wizard SEA 44 46 freemask transmitter rra 46 47 daguala 48 Ei Eleder 48 49 Replacement of modeling lamp 49 Replacement of flash tube 49 50 Regular inspection E 50 Return to customer service rrara 50 11 Disposalern een ee 50 ETORRERAN a Ws re 50 51 13 Customer service rrura 51 Certificate of Conformity rra 52 HENSEL VISIT GmbH amp Co KG 31 User manual Integra Plus Compact flash unit Proper use Improper use 32 3 General safety regulations Compact flash systems store electrical energy in capacitors by applying high voltages These form a source of danger which must be carefully excluded Besides general rules on handling electrical appliances the following safety measurements must be observed Therefore read and comply the safety hints also see paragraph Starting up within the user manual before turning the appliance on The present compact flash unit is meant for studio use of professional photographers Its task is to provide electrical energy for Hensel flash lighting The appliance may not be used for any other purpose than that described above especially not for other electrical appliances Halogen lamps and flash tubes can burst during operation For this reason it is a must to protect modeling and flash light with the suppl
49. t ber Funk gesteuert werden Durch Bet tigung der Taste RC 2 wird der Empf nger aktiviert Der Funksender wird mit der Kamera entweder ber ein Sync Kabel oder ber den Blitzschuh verbunden Die Blitzausl sung kann 3 kanalig erfolgen wobei Sender und Empfangskanaleinstellungen bereinstimmen m s sen Details zur Blitzausl sung per Funk siehe Kapitel 9 Blitzausl sung ber Taste Test Durch Bet tigung des Schalters 6 k nnen Probeblitze ausgel st werden Leistungsregelung Mit dem Blitzenergie Regler 13 l sst sich die gew nschte Blitzenergie stufenlos ber einen Leistungsbereich von 6 Blendenwerten einstellen Auf der dar berliegenden LED Anzeige 14 erscheinen dabei die eingestellten Leistungs werte von 5 0 niedrigste Leistung bis 10 0 Maximal leistung Blitzbereitschaft Die Blitzbereitschaft wird signalisiert durch 1 Aufleuchten der gr nen READY Lampe ber Taste TEST 6 2 Wiederaufleuchten des Einstelllichtes wenn Flash Check 4 aktiviert ist siehe unten 3 ein akustisches Signal wenn AUDIO 3 eingeschaltet ist HENSEL VISIT GmbH amp Co KG Is lo PB IQ Bedienungsanleitung Integra Plus Kompaktblitzgerat APD System Reduziert man die Blitzenergie wird die gespeicherte Energie intern Uber das APD System Automatic Power Drop abgebaut Dabei wird kein Blitz ausgel st Abge schaltete Kompaktblitzger te werden automatisch entla den Es ist auch m glich die Energie ber e
50. t mit EIN Indikator 13 Regler Blitzenergie 14 LED Anzeige Bedienelemente Neiger 15 Kabelklemme 16 Schirmhalter ffnung 17 Justierung des Neigers zum Gewichtsausgleich 18 Schirmfestklemmschraube 19 Sternschraube zur Stativbefestigung 20 Feststellgriff Bedienelemente Funksender 21a Reduzierung der Blitzenergie und Einstelllicht Optionen 21b Erh hung der Blitzenergie 22 Kanalw hler f r 3 Kan le ALL Option Schiebeschalter 23 Testausl ser f r den Blitz 24 Buchse f r Synchronkabel Durchmesser 2 5 mm 25 Feststellschraube f r Montage auf Blitzschuh Hot shoe 26 Schraube zum Offnen des Batteriefaches Der Funksender ist nicht im Standard Lieferumfang enthalten und muss separat bestellt werden Art 3950 oder 3955 12 HENSEL VISIT GmbH amp Co KG Bedienungsanleitung Integra Plus Kompaktblitzgerat 7 Inbetriebnahme Sicherheitshinweise Wegen m glicher Besch digung der Blitzr hre beim Han tieren ist es unbedingt erforderlich vor Einschalten des Kompaktblitzger tes den entsprechenden Lichtformervor satz Reflektor Softbox o zu montieren und das Ger t an seinen endg ltigen Einsatzort aufzustellen Bei jedem Wechsel des Einsatzortes des Kompaktger tes oder des Lichtformers muss das Kompaktger t ausgeschaltet wer den Achtung Nach l ngerem Betrieb sind Lichtformer speziell Reflektoren sehr hei Um Verbrennungen zu vermeiden ist beim Wechseln mit einem W rmeschutz zu hantieren
51. tored in the immediate vicinity of compact flash units to prevent fire hazards e Protect the equipment from moisture including snow and ice dripping or splashing water e Choose safe locations for set up of the equipment and make sure that the equipment cannot fall into pools or bodies of water Never run cables directly along or even through pools or bodies of water e Do not connect accessories from other manufacturers even if they use the same or similar connectors e Flash units hanging from pantographs or ceiling must be doubly secured against falling down e Do not flash into eyes at short distances smaller than 5 m because this can lead to eye damage Do not look directly into the flash reflector e Regularly air closed rooms to prevent build up of inadmissible ozone concentrations which can occur due to the use of high powered flash systems e During work in the studio generating much dust the appliance must be covered with suitable dust pro tection not during operation HENSEL VISIT GmbH amp Co KG 33 User manual Integra Plus Compact flash unit 34 4 Standard delivery All units of the Integra Plus series come with e Flash tube single coated user replaceable e Protection glass dome clear uncoated e Tilting head with integrated umbrella holder e Cable set power and sync cord e Transportation protection cap The radio transmitter is not included in the standard delivery und has
52. unter by pressing the AUDIO button 3 for approximately 3 seconds the number of flashes triggered appears on the LED display 14 as a two digit number the first digit shows the hundreds the second digit the tens The units are truncated e display 05 gt number of flashes triggered between 50 and 59 e display 15 gt number of flashes triggered between 150 and 159 HENSEL VISIT GmbH amp Co KG 43 User manual Integra Plus Compact flash unit Strobe Wizard Plus transmitter Code no 3950 44 Reset of the flash counter is done by pressing the flash power control switch 13 The menu can be left by re peated press of the AUDIO button 3 After 5 sec the menu closes automatically 9 Radio Control System Strobe Wizard Plus The transmitter of the Hensel radio flash trigger and power control system Strobe Wizard Plus is used for triggering flashes adjusting the flash power and switching the modeling lamp between FULL OFF PROP in Hensel flash units with built in receiver via radio signal Every use of the equipment that differs from its prescribed use is prohibited In particular controlling of electronical items or machines other than described above is prohibited Scope of delivery The radio transmitters Code No 3950 or 3955 come with a synchronization cable with 2 5 mm synchronization plug Safety instructions Changing this unit is strictly prohibited The housing is splash proof but not watertight
53. werden Absicherung Steckdosen geb udeseitig Mindestens mit 10 A abgesicherte Steckdosen Absicherung des Ger tes Die Schmelzsicherung 9 dient sowohl der Absicherung des Ger tes als auch der Absicherung des Einstelllichtes Die Integra Plus Serie ist mit einer 4 A Sicherung An sprechverhalten flink 4 AF 5x20 mm abgesichert Die genannten Sicherungswerte gelten jeweils f r Betrieb mit einer 300W Halogenlampe Mehr Informationen auf Seite 24 Sicherung austauschen berhitzung Alle Ger te sind mit einem Gebl se ausgestattet um bei gro en Blitzserien Sch den an der Blitzr hre und am Ger t selbst zu vermeiden Sollte dennoch berhitzung auftreten erscheint an der LED Anzeige 14 die Fehler meldung lt E1 gt Sobald das Ger t abgek hlt ist stellt sich die Fehleranzeige von allein zur ck HENSEL VISIT GmbH amp Co KG Bedienungsanleitung Integra Plus Kompaktblitzgerat T YNC 109 5 LAVE 8 Betrieb Synchronisation Blitzausl sung Synchronisation ber Kabel Das Kompaktblitzger t wird mit Hilfe eines Synchronka bels mit 6 3 mm Klinkenstecker ber die Synchronbuchse 7 an die Kamera angeschlossen Die Synchronschaltung ist auf modernste Halbleiter technologie ausgelegt und erm glicht auch bei lteren Kameras mit mechanischen Kontakten eine sichere Blitz ausl sung Aufgrund der Vielzahl unterschiedlicher elek tronischer Schaltungen in den Kameras zur Steuerung der Synchr