1. 0000005 Refrigeration System 0 ESE ee eee OPERATION Cabinet Operation 0 0 0 eee ee ee eee ELECTRONIC CONTROLLER Controller Display 0 0 00 cee eee ees Temperature Setpoint 0 200 eee ee eee SERVICING Troubleshooting 0 0 0 ccc eee eee Lighting EE enken he ba ee ee Contact Addresses 0 0000 eee eee ei RE OE HE EE EE EE NG SKOPE Counterline amp Slimline Remote Chiller User Manual SPECIFICATIONS Cabinet and Refrigeration Unit Cabinet Construction Finish Stainless steel or powdercoated galvanised steel 50mm thick polyurethane foam Insulation Cyclo iso Pentane blowing agent C H C5H gt Dimensions ledere CL400r 2 CL600r 2 CL800r 2 CC300r 2 CC500r 2 CC700r 2 Doors 2 Door 3 Door 4 Door Height 725mm 725mm 725mm Width 1455mm 2065mm 2675mm Depth 680mm 680mm 680mm Floor area 0 99m 1 40m 1 82m Internal volume 390 litres 600 litres 810 litres Electrical Power supply 220 240 V a c 50 Hz single phase power supply Run Amps 0 35 Amps 0 46 Amps 0 66 Amps Interior light 1x21 Watt 1 x 35 Watt 2x21 Watt Refrigeration Unit Product temp 1 C to 4 C Rated ambient 32 at 65 RH Evap capacity 480 Watts 615 Watts 850 Watts Evaporator CLS9902R TX valve R134a VAL7923 TX valve R404A VAL9641 TX valve R22 VAL9643 Orifice OX REF9761 00 REF7596 00 REF7596 Refrigerat
2. Clean condenser temperatures and or compressor operating for long periods more than 1 hour Ensure the cabinet is installed with good ventilation around the refrigeration unit Poor refrigeration unit ventilation Table 5 Troubleshooting SKOPE Counterline amp Slimline Remote Chiller User Manual 15 SERVICING Controller Alarms CODE DISPLAY ICON ALARM DESCRIPTION Product HIGH temperature alarm Product LOW temperature alarm Refrigeration system high temperature pre warning gt Refrigeration system high temperature shutdown Ambient probe fault Evaporator probe fault Condenser probe fault Defrost over time limit Real time clock fault Controller E prom error Controller E prom error Start defrost request End defrost request Table 6 Controller Alarms 1 6 SKOPE Counterline amp Slimline Remote Chiller User Manual SERVICING INITIAL ACTION FINAL ACTION Check the cabinet product loading to ensure ventilation slots are not blocked and that product does not overhang the shelves Ensure the cabinet is installed with good refrigeration unit ventilation Check and clean the condenser coil Unplug cabinet from the power supply for 1 minute then reconnect to power supply Clean the condenser coil Check refrigeration ventilation Ensure clear airpath at the top and front of the cabinet to extract hot air A minimum of 200mm clear space is required in
3. fully evacuated prior to charging e All cabinet penetrations are sealed 8 SKOPE Counterline amp Slimline Remote Chiller User Manual INSTALLATION Electrical The cabinet is supplied with a 3 core 10 Amp mains flex and plug The cabinet lighting and centre pillar heater elements are protected by a 3 Amp fuse located in the unit junction box lf a solenoid is fitted and controlled by the electronic controller the solenoid will need connected to the connector block inside the unit junction box Unit Pipework Cover Refrigeration Unit Compartment Suction Line Drain Tube Liquid Line Rear of Cabinet Figure 2 Refrigeration Pipework SKOPE Counterline amp Slimline Remote Chiller 9 User Manual OPERATION Cabinet Operation Plug in the machine and check operation of the refrigeration unit and cabinet lights The electronic controller and evaporator fan motor should operate initially Note If the solenoid valve is fitted and operated by electronic control then the solenoid should open when compressor indicator is shown Checking operation e The solenoid compressor relay should switch off when cabinet internal temperature reaches approximately 1 C and on again at approximately 4 C The internal cabinet air will continue to circulate at all times e The light switch located next to the electronic controller on the refrigeration unit front cover activates the cabinet interior lighting and can be switched on
4. E Counterline amp Slimline Remote Chiller User Manual Swing Door Frame Lockable Castor Power Cord Figure 1 Power Cord Clip INSTALLATION Refrigeration System Drain A 500mm long 19mm O D PVC drain hose is supplied see Figure 2 on page 9 All drainage is to conform to local regulations covering removal of condensate to waste water Ensure drain is trapped with adequate fall Venting the drain may be required for a restrictive run Refrigeration lines A 1 4 liquid line and 3 8 suction line are provided to attach pipe lines to The suction lines must be insulated NOTE The electronic controller supplied with the cabinet can switch a solenoid No solenoid is supplied with the remote unit Refrigeration Practice Installation must be performed by a refrigeration tradesperson to an appropriate standard complying with all local regulations Performance depends on the overall installation including condensing unit Cabinet suitability must always be quantified for the application The final responsibility for condensing unit performance and component selection rest with the installer The installer must check matters such as e Heat load e Refrigeration load e Variable operating conditions usage ambient humidity e Refrigeration pipe sizing e Refrigeration pipe length distance elevation pressure drop e Location and ventilation cabinet and condensing unit e Drainage e Power supply e Unit is
5. User Manual SKOPE Counterline amp Slimline Chillers CL400 600 800r 2 CC300 500 700r 2 REMOTE models Model CL600r 2 3SD SKOPE Refrigeration MANO686 Rev 3 0 Feb 2008 edition SKOPE Counterline amp Slimline Remote Chiller Models CL400 600 800r 2 amp CC300 500 700r 2 User Manual MANO686 Rev 3 0 Feb 2008 edition Copyright 2007 SKOPE Industries Limited All rights reserved SKOPE Industries Limited reserve the right to alter specifications without notice SOEP is a registered trade mark of SKOPE Industries Limited TRADE MARK INFRINGEMENT The SKOPE trade mark on this product is infringed if the owner for the time being does any of the following e Applies the trade mark to the product after their state condition get up or packaging has been altered in any manner e Alters removes including part removal or obliterates including part obliteration the trade mark on the product e Applies any other trade mark to the product e Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to e Successors or assigns of the buyer e Future owners of the product SKOPE Counterline amp Slimline Remote Chiller User Manual TABLE OF CONTENTS SPECIFICATIONS Cabinet and Refrigeration Unit INSTALLATION Safety Information Installing the Cabinet
6. be 1 8 SKOPE Counterline amp Slimline Remote Chiller User Manual SERVICING Contact Addresses New Zealand SKOPE INDUSTRIES LIMITED Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz Australia SKOPE AUSTRALIA PTY LTD A C N 000 384 270 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au Warranty To receive a warranty for your purchased cabinet you MUST register your cabinet within four weeks from the date of invoice either by e filling out the in cabinet warranty form and posting or faxing it back to SKOPE e or filling out the online warranty form Cabinets that are not registered within the four weeks are not eligible for a warranty SKOPE Counterline amp Slimline Remote Chiller 19 User Manual
7. e 3 Controller Display Keypad ITEM FUNCTION Prg mute To initiate programme sets press for 5 seconds Mutes mute the audible alarm buzzer and deactivates the alarm relay Ena UP aux To scroll settings UP in programme mode Set If pressed for more than 2 seconds displays and or enables changing the temperature setpoint see page 14 4 DOWN def To scroll settings DOWN in programme mode Table 2 Keypad Functions 1 D SKOPE Counterline amp Slimline Remote Chiller User Manual ELECTRONIC CONTROLLER Icons ITEM ICON FUNCTION COMPRESSOR ON when the compressor and condenser fan starts Flashes when activation of the compressor is temporarily delayed FAN n a DEFROST ON when the defrost is activated Flashes when the activation of the defrost is temporarily delayed due to procedures in progress AUX n a DES ALARM Flashes in the event of alarms SERVICE Flashes in the event of malfunctions DISPLAY Shows the cabinet temperature 14 HACCP HACCP n a CONTINUOUS CYCLE n a Table 3 Icon Functions SKOPE Counterline amp Slimline Remote Chiller 4 3 User Manual ELECTRONIC CONTROLLER Temperature Setpoint The chiller temperature setpoint is factory set at 1 0 C If necessary the standard setting can be adjusted between 0 5 C and 3 5 C see Table 4 below SKOPE do not recommend that the setpoint be changed unless it is absolutely necessary and then only by small increments at a t
8. front of the refrigeration unit Ensure the cabinet is installed in a suitable environment Unplug cabinet from the power supply for 1 minute then reconnect to power supply If alarm persists contact SKOPE Unplug cabinet from the power supply for 1 minute then reconnect to power supply None None SKOPE Counterline amp Slimline Remote Chiller User Manual 17 SERVICING Lighting Cabinet Interior Lights Depending on the model cabinet the chiller is fitted with either one or two fluorescent tubes See Table 7 below for the correct tube size Model Fluorescent Tube ba Watt T5 fluorescent tube 16mm x 850mm daad 35 Watt T5 fluorescent tube 016mm x 1450mm az 21 Watt T5 fluorescent tube 016mm x 850mm Table 7 Fluorescent Tube Sizes To Replace a Fluorescent Tube 1 Disconnect the cabinet from the mains power supply 2 Remove the top light diffuser by compressing the back section of the diffuser until it disengages from the aluminium housing and then push the diffuser back see Figure 4 below 3 The fluorescent tube can now be removed by revolving the tube until the pin position allows withdrawal 4 When refitting the light diffuser engage the back section into the housing and then compress and snap the front section of diffuser back into place working along the full length of the light Fluorescent Tube Top Light Diffuser Figure 4 Replacing the Fluorescent Tu
9. he shelf support brackets into the shelf support strips at the desired heights and fit the shelves The shelves may be positioned at different heights to suit various products Always ensure that the shelf clips are securely engaged in each of the shelf support strips The shelf support strips are marked for easy location of shelf clips and can be lifted up and removed for cleaning purposes 6 SKOPE Counterline amp Slimline Remote Chiller User Manual INSTALLATION Power Supply The chiller is supplied with a 2 3m flexible power cord fitted with a 3 pin plug which exits below the refrigeration unit front cover Initial retrieval of the power cord is from inside the refrigeration unit compartment behind the unit front cover To retrieve the power cord 1 Open the unit front cover by undoing the bottom fixing screw and then lifting the cover up from the bottom and swing open Pull the power cord fully out from the unit compartment and remove the rubber band Push the unit end of the power cord into the grey plastic clip on the front of the unit base and close the plastic clip over the cord ensuring it is held firmly in place see Figure 1 below The power cord can now be run under the cabinet and plugged into a power supply socket Close the unit front cover by lifting the cover up from the bottom and pushing firmly closed Remember to refit the bottom fixing screw Condenser Coil Unit Base Plastic Clip SKOP
10. ime To View and Adjust the Temperature Setpoint To view the setpoint press and hold the SET key for 2 seconds until the setpoint value flashes To adjust the setpoint press either the UP or DOWN keys to display the required setpoint value 3 Press the SET key again to memorise the new setpoint value If this is not done within 60 seconds changes will be lost and you will need to repeat the above procedure Table 4 Viewing and Adjusting the Temperature Setpoint 14 SKOPE Counterline amp Slimline Remote Chiller User Manual SERVICING Troubleshooting Complaint Possible Cause Cabinet not e Loss of power supply e Check mains power supply operating and no controller display Cabinet lights not Blown cabinet fuse Requires technical repair by a operating SKOPE Authorised Service Agent Failed fluorescent tube Check fluorescent tubes Controller alarm Determine cause and eliminate see pages 16 17 Power Unit operating too hot Clean condenser Ensure the chiller consumption is is installed with good ventilation higher than around the refrigeration unit expected e Cabinet door is opened excessively Keep door s open for minimum time Product is too Restricted cabinet airflow Ensure product is not blocking warm and airflow slots and there is air space spoiling around all the product Temperature setpoint is too warm Adjust setpoint see page 14 Warm cabinet Blocked condenser
11. ion tail Liquid line 1 4 Suction line 3 8 Drain 19mm O D Height excludes castors or legs Depth with optional worktop is 700mm additional 20mm Table 1 Specifications 4 SKOPE Counterline amp Slimline Remote Chiller User Manual INSTALLATION Safety Information When using any electrical appliance safety precautions should always be observed Read these instructions carefully and retain for future reference e When used by or near young children or infirm persons close supervision is necessary Young children should be supervised to ensure that they do not play with the appliance e Do NOT use this appliance for other than its intended use e Do NOT cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit e Do NOT probe any opening e Do NOT overload the power supply See the rating label inside the cabinet for power supply and current draw e Only use this appliance with voltage specified on the rating label e Ensure adequate ventilation of the SKOPE refrigeration unit e Be careful not to touch moving parts and hot surfaces e Regulations require that all electrical work be carried out by authorised persons For your own safety and that of others ensure this is done e If the supply cord becomes damaged it must be replaced by a SKOPE authorised service agent or similarly qualified person in order to avoid a hazard e This chille
12. or off as required e For efficient operation ensure the door gaskets form a good seal with the cabinet Loading Product The chiller should be left running for 30 minutes before loading with product When loading the cabinet shelves with product e Allow air space around all the product to ensure even cooling and efficient operation of the chiller Leave airsoace above product loaded on the top shelf and leave a gap of approx 50mm next to the return air grille between the cabinet interior and the refrigeration unit compartment e Do not allow products to overhang the front of the shelf as this could prevent the doors from shutting or cause glass breakage Do not exceed a maximum loading of 195 kg m2 e Remove some product if the shelves are flexing or bending 1 O SKOPE Counterline amp Slimline Remote Chiller User Manual OPERATION Cleaning When necessary wash both the interior and exterior of the cabinet with soapy water Ensure the machine is disconnected from the mains power supply before washing the cabinet with water The shelf support strips can be lifted up and removed for cleaning purposes Exterior of cabinet may be waxed with automobile polish for extra protection Caution Disconnect the chiller from the mains power supply before washing the cabinet with water SKOPE Counterline amp Slimline Remote Chiller gg User Manual ELECTRONIC CONTROLLER Controller Display 122 3 oe Figur
13. r is not designed to be stable in motion Exercise caution when moving or transporting this chiller Caution Disconnect the cabinet from the mains power supply before attempting any cleaning or maintenance SKOPE Counterline amp Slimline Remote Chiller 5 User Manual INSTALLATION Installing the Cabinet Castors Legs lf your SKOPE Counterline Chiller has been supplied with either the optional adjustable height castors or adjustable legs packed with the cabinet they should be fitted to the base of the cabinet before final positioning of the chiller IMPORTANT Do NOT lay the chiller onto its back when fitting the castors or legs Positioning When positioning the chiller avoid direct sunlight and warm draughts etc Adequate allowance should be made for door opening The chiller must be positioned on a level surface for the doors to shut and seal correctly and to prevent the condensate tray from overflowing Ventilation For efficient operation of the chiller it is essential that adequate ventilation be provided around the refrigeration unit The maximum recommended operating ambient temperature is 32 C at 65 RH for standard cabinets and 40 C at 75 RH for tropical cabinets Warning Never store cardboard cartons or other items in front of the refrigeration unit The ventilation slots in the unit front cover must be kept clear at all times Shelves Remove all packaging material from the shelves Clip t