Home
USER MANUAL
Contents
1. Enter the first digits of the number needed to recognise the number type Select the Type as BARRED or ALLOWED Click on Add or Delete to enter or remove the number from the list Require Allowed Numbers If the block is not ticked it will allow all the numbers that are not barred Allow Incoming Calls The SS 10 can be set to allow or ignore incoming calls Auto Call Termination The SS 10 can be set to terminate a call after a set duration DOC NO SS 10 14 REV 03 Page 16 of 20 7 4 SMS OPTIONS SS 10 USER MANUAL SMS Options The SS 10 can be set to send fault reporting via SMS to a required destination number lt can authorise two users to control the unit via SMS SS 10 Setup Call Parameters Call Barring SMS Options Network Audio Profile Reporting Setup Report Destination 27828221381 Report Identity Get IMEI 358062003673066 6 68 Routine Report interval 6 40 SMS Control Info Authorised User 1 Authorised User 2 SMS Service Centre Number Type 27831000113 145 No Call report interval Rev 3 xx SMS fix 27828221381 Execute 27837018612 Fetch settings H Save Settings amp Load Settings Update 55 10 Reporting Setup Feed bridge voltages GSM voltage Number of unanswered calls Number of answered calls Total duration of answered calls Report Destination Destination number for reports to be sent Country code to be in
2. Receive Levels Set receive levels 0 255 64 normal Value 32 64 128 255 Relative Level 12 dB 6 dB 0dB 6 dB Description Softer Factory Setting Louder Loudest Page 8 of 20 SS 10 USER MANUAL 5 2 REPORTING SETUP Parameter Description Notes No Call SMS Report 10 Set the interval in minutes after which a report may be sent by SMS if no calls have taken place Set to 0 to disable no call reporting Routine Reports 41 Set the interval in minutes between routine reports that will be sent by SMS to the pre programmed destination Set to 0 to disable routine reporting SMS Report Destination 12 Sets the destination number for SMS report Please include country code Eg 27828221381 SS 10 Identity 13 This command is only available from the serial port It is used to set a 16 character ID so that the SS 10 can identify itself in SMS messages that are sent 5 3 CALL DETAIL REPORTING Parameter Description Notes Call Record Prefix 20 Sets up a 2 digit number that will prefix call records that are output from the SS 10 The prefix is the line of the Extension or Trunk number to identify the SS 10 to which the CDR record belongs DOC NO SS 10 14 REV 03 Page 9 of 20 SS 10 USER MANUAL 5 4 SIM amp NETWORK Parameter Description Notes Sets the PIN Sets the PIN
3. or 16 KHz Version 1 17 and below Dial In modem functionality Version 1 23 and above 4 minute timer to reset GSM module if not registered on the network 2 3 MAINTENANCE FEATURES Routine periodic SMS reports Version 1 23 and above Feed bridge voltages GSM voltage Number of unanswered calls Number of answered calls Total duration of answered calls SMS report on zero traffic no calls made for specified interval Request reports Request setting information Change set up information by SMS 2 authorized maintainers Programmable by serial port telephone or sms O 0O O 0 Oo DOC NO SS 10 14 REV 03 Page 5 of 20 SS 10 USER MANUAL 3 DESCRIPTION 3 1 FRONT VIEW ON OFF button Power Indicator Holding in the On Off button while the Busy Indicator unit is powered up enables setup mode Network Indicator SS 10 ON OFF PWR BUSY NET F s 6 Cc SIM CARD e E JA A A um M SIGNAL SIM card Press for Signal strength SMA antenna tray opening indicator connector SIM tray 3 2 REAR VIEW Line Connector PC Connector DC Connector RJ 11 Connector DB9 Female Used for Connects a DC voltage setup purposes between 12V and 18V to Only pins 2 amp 3 Use a standard PC the unit are used serial cable for Pin Description connecting the unit to Inside DC positive voltage aPC Outside GROUND DOC NO SS 10 14 REV 03 Page 6 of 20 SS 10 USER MANUAL 4 SETUP Setup of
4. parameter number and ddd is the required setting DOC NO SS 10 14 REV 03 Page 7 of 20 SS 10 USER MANUAL 5 SETTABLE PARAMETERS 5 1 BASIC SETUP Parameter Description Notes 01 Total Digit Count Sets the total number of digits required before dialing It is recommended that this parameter is set to 10 02 Dial Timeout Set dial timeout in 10 of a second Normally 4 seconds This is the time taken before the call proceeds when numbers shorter than the total digit count are dialed 03 Call Progress Tones Enable 1 disable 0 call progress tones 04 Polarity Reversal Signalling Set reversal time in 10 of a second To enable reversal on answer add 100 to the number input E g 04 20 sets the time to 2 0 seconds without reversal on answer and setting 04 120 sets it to 2 0 seconds WITH reversal on answer 05 Break Pulse Signalling Set the break time in 10 of a second Some PABX systems require a current break to indicate that the call has terminated The SS 10 can provide such a break If it is not required then set this parameter to 0 06 Call Line Identification Restrict CLI 1 or allow CLI 0 07 Transmit Levels Set transmit levels 0 255 64 normal Value 32 64 128 255 Relative Level 12 dB 6 dB 0 dB 6 dB Description Softer Factory Setting Louder Loudest 08 DOC NO SS 10 14 REV 03
5. the SS 10 can be done by using one of the following methods SMS Setup Method Sending SMS commands to the unit Telephone Setup Method Using a telephone connected to the SS 10 PC Serial Port Setup Method Sending commands to the unit by connecting it to a PC and use a Comms package like HyperTerminal or PC Serial Port Setup Method Connect the unit to a PC using the SS 10 Tool package Using SS 10 Toolkit Load the SS 10 Tool and refer to the notes Setup of the unit by using the SS 10 Tool Sending SMS commands The format of the commands using SMS is as follows Using a Telephone Setup Mode must be enabled Holding in the On Off button while the unitis powered up enables setup mode on the SS 10 lt n gt lt val gt lt 2nd val gt where lt n gt is a command number and lt val gt is a value More than one command can be entered per SMS The command are separated by using the newline character Typically one would end the command set with a display command to confirm that the requested changes have been executed Dial the following lt nn gt lt ddd gt Where nn is the parameter number and ddd is the required setting Sending Commands using a Comms package From the serial port the format is e lt nn gt lt ddd gt lt enter gt or lt nn gt lt ddd gt lt enter gt Where nn is the
6. FEACSDB45F 4E 6DD6C22FF9E 8CDE 311 4283BE5BDO0F2C504BCEE 16F28C3B 4D 200205 61E BC6D587495D BF 7DFD 2E 208F544637E BCBSSA0FI 5B29D 834188 3F6776942B 1F24E 273E 4F3F0B280941 43851 6D 1E8961FC5141CC6C2995CE033165438 v E LE Ej S This button is used to load new or alternative audio parameter files Load that may be released from time to time and are not yet included in the SS 10 Uploader program Def This button loads the default parameter set that was shipped with the TC 35i s w revision 02 07 Vet This will load the parameter set that provides echo cancelling and noise reduction functionality This loads the parameter set that provides echo cancelling without the V 2 noise reduction This is the preferred option to use but in exceptional circumstances the other file can be used Clicking on this button will initiate an update of the TC 35i Basic Update checking is done to ensure that a TC 35i is present and that it is running s w revision 02 07 DOC NO SS 10 14 REV 03 Page 18 of 20 SS 10 USER MANUAL 8 UPGRADE OF THE SS 10 FIRMWARE Download Firmware The latest firmware for the SS 10 is available from http www sstelecoms com Connect unit to PC Connect the SS 10 unit to the PC by using a serial cable and make sure it is switched on Upgrade the Load the SS 10 Tool Program D Firmware by using the A SS 10 Tool Click on ComPort to sel
7. SS telecoms our solutions your success 95 10 FIXED CELLULAR TERMINAL lt gt pi ON OFF PWR BUSY NET zz ee j SIMCARD 4 YY 6 M SIGNAL USER MANUAL Revision History Revision 01 Revision 02 Revision 03 1 INTRODUCTION 2 FEATURES 2 1 PHYSICAL FEATURES 2 2 SOFTWARE FEATURES 2 3 MAINTENANCE FEATURES 3 DESCRIPTION 3 1 FRONT VIEW 3 2 REAR VIEW 4 SETUP samir 5 SETTABLE PARAMETERS 5 1 BASIC SETUP 5 2 REPORTING SETUP 5 3 CALL DETAIL REPORTING 5 4 SIM amp NETWORK 5 5 AUTHORIZED USER 5 6 HARDWARE SETTINGS 5 7 METER PULSE GENERATION 5 8 POWER DOWN TIME 5 9 CALL BARRING 5 10 MISCELLANEOUS 5 11 SETUP INFORMATION 6 SERIAL PORT COMMANDS 6 1 SIMPLIFIED SERIAL PORT COMMANDS SS 10 USER MANUAL Original document 2004 Cosmetic changes 12 February 2008 Auto Call termination and GUI 26 January 2009 CONTENTS 7 SETUP OF THE UNIT BY USING THE SS 10 TOOL 7 1 MAIN WINDOW a nie am eid i 7 2 CALL PARAMETERS a orietan ainina aiea EEE Eaka E aare AA Aa taR a Eein ia 7 3 CALL BARRING cion a a A ci 7 4 SMS OPTIONS prietarai aae pa aae EA EEEE EE aA ap ea PEE a N Ei E 7 5 NETWORK ne ne eaa a less ie ste a te 7 6 AUDIO PROFILES ccoo 8 UPGRADE OF THE SS 10 FIRMWARE suisse DOC NO SS 10 14 REV 03 Page 2 of 20 SS 10 USER MANUAL 9 TECHNICAL SPECIFICATIONS sisi 10 CON
8. SimPin1 It is only needed if the SIM card has its PIN set Using a PIN locked SIM The SIM can be loaded into the SS 10 using the command 30 nnnn lt enter gt where nnnn is the PIN number It is important to make sure that the PIN is entered correctly If the PIN is not correct then the SS 10 will 30 output a message on the serial port indicating this It will also flash the IN USE and NETWORK LED s in an alternating pattern until it is powered down Note that after 3 attempts the SIM will be blocked and the PUK will have to be used to unblock the SIM This will need to be done using a normal GSM handset Using a BLANK SIM If the SIM card is setup without a PIN no further action needs to be taken as the SS 10 will recognize that no PIN is required and it will automatically log onto the network Set Network Operator 5 digit network code use space for automatic network selection 31 Vodacom MTN Cell C 65501 65510 65507 5 5 AUTHORIZED USER Parameter Description Notes Authorised User 1 32 Gives authorisation to user 1 for controlling access to the SS 10 unit via SMS by entering the user s numbers Country code to be included e g 27828221381 Authorised User 2 33 Gives authorisation to user 2 for controlling access to the SS 10 unit via SMS by entering the user s numbers Country code to be included e g 27828221381 DOC NO SS 10 14 REV 03 Page 10 of 20 SS 10 USER MANUAL 5 6 HARDWARE SETTINGS Pa
9. TACT DETAILS DOC NO SS 10 14 REV 03 Page 3 of 20 SS 10 USER MANUAL 1 INTRODUCTION The purpose of the SS 10 Fixed Cellular Terminal FCT is to provide a means of making telephone calls where there is no fixed line infrastructure or where it may be more cost effective to use the GSM infrastructure for carrying the call ARCHITECTURE Least Cost Routing Least Cost ES A AU Rural Telephony MN AN IFRS I AU MN GSM Tower i I GSM Tower DOC NO SS 10 14 REV 03 Page 4 of 20 SS 10 USER MANUAL 2 FEATURES 2 1 PHYSICAL FEATURES Matches to complex line impedance Power saving feed bridge Signal level indicator LEDs Busy indicator Network indicator SMA antenna connector GSM On Off switch allows Network Detach Power supply 300mA at 12 VDC RJ11 connector for telephone DB9 connector for programming 900 MHz or 1800 MHz operation 2 2 SOFTWARE FEATURES Comfort Tone CLI restriction Settable digit count Settable dial timeout Automatic call termination Transmit amp receive levels adjustable Optional reversal Optional line current break Optional periodic module reboot Version 1 23 and above Full rate enhanced full rate amp half rate operation Preferred network selection Network locking Version 1 23 and above SPM pulses at settable interval 12 KHz
10. cluded e g 27828221381 Report Identity Identity to be sent with report for identifying the unit Click on Get IMEI to retrieve the number from the unit or use any custom text as the identity No Call Report Interval A report will be sent if no answered calls have been made for this period of time Routine Report Interval Fixed intervals between sending of reports SMS Control Info Authorised User Give authorisation to two users for controlling the access to the SS 10 unit via SMS by entering the user s numbers Country code to be included e g 27828221381 SMS Service Centre Number Enter the SMS service number for the network Type After entering the service number click on Read to automatically get type from the network 7 5 NETWORK SS 10 USER MANUAL Network Select the required Network and Reset Interval if needed SS 10 Setup Call Parameters Call Barring SMS Options Network Audio Profile Network Selection Automatic C Vodacom C MTN C CellC C Other Reset Options Reset Interval 766 Update 55 10 Fetch settings H Save Settings Load Settings Network Selection When using Other the 5 digit network operator code should be obtained from the local Network Operator Reset Interval Set the interval in hours and minutes between forced network log offs 7 6 AUDIO PROFILES Audio Profi
11. d to display the number list 61 An extra digit will precede the number 2 Indicates an allowed number 1 indicates a barred number Note Command will only work in serial setup mode Add Number 62 Add a 2 before the number to allow the number Add a 1 before the number to bar the number Set Need Allowed 65 When this is set to 1 all numbers will be barred by default and allowed numbers have to be explicitly enabled 5 10 MISCELLANEOUS Parameter Description Notes 80 Clear Totals Resets the report values 81 Set Report Timer Sets the time interval for the report timer 5 11 SETUP INFORMATION Parameter Description Notes 96 Reboot the GSM Module Should be used after level changes 97 Sends a report back to originator 98 Sends SMS 99 Displays the settings DOC NO SS 10 14 REV 03 Page 12 of 20 SS 10 USER MANUAL 6 SERIAL PORT COMMANDS 6 1 SIMPLIFIED SERIAL PORT COMMANDS Simplified basic commands for entering via the serial port generally used for diagnostic or basic setup purposes Instruction Description Notes DR lt enter gt Gives a short report on state AT lt ddddddd gt lt enter gt Sends the data dddd to the cell module RESET lt enter gt Resets the SS 10 DIAG lt enter gt Toggles the diagnostic state of the SS 10 SMS lt enter gt Sends a test SMS to the pre programmed destination lt nn gt lt ddd gt lt enter gt Sets parameter
12. ect the required COM Set the BaudRate to 9600 From the File Menu choose Open and select the required Firmware file e Click the UpLoad Firmware button to upload the new firmware to the unit e Remove the serial cable from the unit after setup Y 9 TECHNICAL SPECIFICATIONS Housing Black powder coated Aluminum 147 x 90 x 26 mm POWER IN USE NETWORK SIGNAL STRENGTH LED indicators Connectors PC connection 9 way D Type female LINE connectors RJ11 POWER connection 2 1 mm DC socket Set up Set up data is stored in non volatile memory Setup can be done by using a telephone or PC Eemparibilrd Compatible with most PABX s Required voltage 10 VDC to 16 VDC Current consumption 300 mA DOC NO SS 10 14 REV 03 Page 19 of 20 SS 10 USER MANUAL telecoms our solutions your success 10 CONTACT DETAILS Office 23 Botha Avenue Lyttelton Manor Pretoria Gauteng South Africa Tel 27 12 664 4644 Fax 27 86 614 5625 E mail info sstelecoms com Postal address Postnet Suite 48 Private Bag x 1015 Lyttelton 0140 Pretoria Gauteng South Africa Sales Support South Africa E mail sales sstelecoms com United Kingdom E mail uksales sstelecoms com Technical Support E mail support sstelecoms com DOC NO SS 10 14 REV 03 Page 20 of 20
13. le Audio updates can only be used on the TC 35i s w revision 2 07 and later 55 10 Setup Call Parameters Call Barring SMS Options Network Audio Profile Lines 35 No Noise Cancel 2005 09 15 A BEEBE 97D3BBS4E83C5F8EB19C4476F1425F62F9154BC906F3F6C2E 71E5D7E78D31F7C9115544D6 C08345FB01503361C08345FB01503361ECFEOCABE 99866F400576CE 84 C07936C08345FE 01503361 C08345FB01503361434554699138178F4CB0D7748DF5448CA44456DA4B434549B1BB49081C061384723E 15D03CB0E1 4039F4345546991381 78FIDEFAF2CDC34F4E 4029028 8B S6E 272E 9FBC1BECF2E 1086E 7F2CAF429C81ED18E 22E 408CB50F05624201E976B 7655D 0041 COE 839B 56D 648D6C887E 59BF97304 SOCE B6F543E 1F4F 331 B64CE DC98BF1D8B27122C9E 08437058 49081 C61 384723636834598987BAB 02 4345546991 381 78F 455BB 7467408468 282D 8544038 506BFDC08345FB01 503361 1BC1C680794B831FD 4345546991 381 78F591F08D971D2EE 364FC3CDDDS4CBOF73FBC1BECF2E 1086E 97F2CAF429C81ED 0374E6414380370E00576CE84EC079362E164C26EC4138FB9F57FE2 AD7FOD7790CEBEFSA3E1F4F 7A61E53D7CCB4FE300576CE84ECO7935C08345FB0150336158FBE7979EE54B74434554699138178F 9F394 456661F441004CD162E 82307516886 240774DCD 27BBC08345FB 01503361 C08345FB01 503361 B57256663B 74C593759D 8B DE 1029491 34C85E 1129454005 51E61EC8F 42471 25E 6945300601 43CF4 C7345940FC32B04052F6E D3E 74CF655E 0FF3C041D9FB4980719302791D19732142CCBC76E SBDO90 719E7FCB8C91 26CCD 24E48616E 377DD 3E 5FB957798D4961 C2D 07D 44391 BDO761 7C0373DD95011F4 853086025942875E 27281 9B861F 4D 3088481 3B 0B 20B5FBA296
14. nn to value ddd SETID lt sssss gt lt enter gt Sets the ID of the SS 10 to sssss This is used to identify the particular SS 10 site name when automatic SMS messages are sent DOC NO SS 10 14 REV 03 Page 13 of 20 SS 10 USER MANUAL 7 SETUP OF THE UNIT BY USING THE SS 10 TOOL 7 1 MAIN WINDOW ai icix File Font COM1 9600baud Setup Quick Check D A Upload Firmware SS 10 Tool Main Window IMEI YER 3580 6200 367 3066 Load the SS 10 Tool GSM SAW REV 03 01 GSMHAWTC35 55 10 Rev 1 38H Click on COM1 then 89270761006050267896 click on Refresh to do AudioProfile 21 automatic baudrate i 65dBm detection A Firmware version 63 61 JV Show Signal TC 35i detected S 1 Rev 1 38H Address 003F00 SE3D 0 _ Source File gt gt lC andre_TestiTest5w 551015510_FCT_1_36H hex Display the following IMEI VER IMEI Software Revision and Hardware type of the GMS engine SS 10 Firmware revision number To update the firmware load the Firmware file from the File Menu UpLoad Firmware Use UpLoad Firmware button to load the Firmware into the unit Refer to the Upgrade Firmware section for the complete procedure Tick the Show Signal box for a visual and measured indication of the Show Signal signal strength DOC NO SS 10 14 REV 03 Page 14 of 20 SS 10 USER MANUAL 7 2 CALL PARAMETERS Click on SETUP to start with the setu
15. p of the SS 10 Call Parameters Call setup Audio and Line levels can be changed in this window SS 10 Setup 5 Call Baring SMS Options Network Audio Profile Call Setup Audio Parameters Dialled Digit Count 10 4 0 CLI Restriction M Call Progress Tones E Reversal Time 1 0 Reversal on Answer 12 Break Time 1 A Q Dial Timeout RX Level 1 6 dB Line Settings On Hook Voltage 135 Y Off Hook Voltage 25 Y Ring Voltage SPM settings ai G SPM Interval Qa Show for un answered call KE Save Settings Update 55 10 Fetch settings Load Settings Call Setup Dialed Digit Count Sets the total number of digits required before dialing It is recommended that this parameter is set to 10 Dial Timeout Sets dial timeout in 10 of a second This is the time taken before the call proceeds when numbers shorter than the total digit count are dialed Nominal value is 4 seconds CLI Restriction Restricts or allows Call Line Identification Call Progress Tones Enables or disables Call Progress Tones Reversal Time Sets reversal time in 10 of a second Reversal on Answer Enables or disables Reversal on Answer Break Time Sets the break time in 10 of a second Some PABX systems require a current break to indicate that the call has terminated If it is not required then set this to 0 Show for un answered call When
16. rameter Description Notes 40 On Hook Voltage The On Hook voltage can be set with this command The allowed range is from 20 volts to 40 volts Nominal value is 35 volts 41 Off Hook Voltage The Off Hook voltage is set using this command It can be set from 18 to 30 volts The nominal value is 25 volts This allows power usage to be reduced during conversations which reduces heating in confined spaces 42 Peak Ring Voltage Sets the peak ring voltage The range is 40 to 60 volts The factory setting is 50 volts normally this setting will not require adjustment 5 7 METER PULSE GENERATION Parameter Description Notes 50 12 KHz or 16 KHz Set the frequency to 12KHz or 16KHz for Subscriber Private Metering Only available in Ver 1 17 51 Pulse Interval Sets the interval in seconds between SPM pulses Setting a value of 0 will disable SPM 5 8 POWER DOWN TIME Parameter Description Notes 55 Power Down Time Time in minutes between forced network logoffs 56 Automatic call termination Time in minutes before call termination DOC NO SS 10 14 REV 03 Page 11 of 20 SS 10 USER MANUAL 5 9 CALL BARRING Parameter Description Notes 60 Incoming Calls Prohibits incoming calls 1 allows incoming calls 0 Display Number Table Use
17. ticked the graph will display the reversal sequence for an unanswered call Audio Parameters TX Level Sets Audio Transmit level Nominal value is 6 dB RX Level Sets Audio Receive level Nominal value is 6 dB Line Settings On Hook Voltage The allowed range is from 20 to 40 volts Nominal value is 35 volts Off Hook Voltage lt can be set from 18 to 30 volts The nominal value is 25 volts This allows power usage to be reduced during conversations which reduces heating in confined spaces The range is 40 to 60 volts The factory setting is 50 volts normally this Ring Voltage setting will not require adjustment SPM Settings 12KHz Sets the frequency to 12KHz for Subscriber Private Metering Only available in Ver 1 17 16KHz Sets the frequency to 16KHz for Subscriber Private Metering Only available in Ver 1 17 SPM Interval Interval between SPM pulses DOC NO SS 10 14 REV 03 Page 15 of 20 SS 10 USER MANUAL 7 3 CALL BARRING Call Parameters Call Barring SMS Options Network amp Security Audio Profile Number Type BARRED X X Delete Call Barring Require Allowed Numbers f Allow Incoming Calls Iv Calls can be barred or allowed E i F Call Duration h mm 1 66 Upload Numbers to 55 10 Iv Fetch Numbers from 55 10 lv Total Records 0 Update 55 10 Fetch settings m Save Settings Load Settings
Download Pdf Manuals
Related Search
Related Contents
Shark GI305 Use and Care Manual Viewsonic DPG801BK digital photo frame ASUS CP220 User's Manual MasterTop 135 Piston Predial 1/3 Jet Flex - Manual Técnico Home Decorators Collection 0529900910 Instructions / Assembly CORDOVA_CLAUDIA ON_FIBRAS_ACERO_WIRAND Operators Manual March 2008 Jura 68166 Manual de instalação do driver Windows® Para Copyright © All rights reserved.