Home
New - Generex
Contents
1. Data archiving capability for all batteries up to 12 years on an integrated Flashcard Alarm data archiving using log file with time and date Equipped with a real time clock and additional synchronization capability with a network time server Completely replaces any UPS SNMP adapter Option Modem Analog GSM for integration into RASCONTROL tele assistance system This highly developed Ethernet Manager with LCD Display can be used for monitoring up to 500 BACS C10 or C2x modules For the C1 C7 modules the maximum limit is 190 as with the current BACS WEBMANAGER Type I BACS Battery analysis for 66 batteries graphically displayed using the BACS VIEWER Each change in impedance temperature voltage and bypass is recorded regularly Further technical details will be made available in February 2008 GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 New Webtarget 2D 2E With more memory for SM and BACS WEBMANAGER New in our program is the MWT2E as a low power version of the CS121 R RIELLO Slot Adapter With this module the CS121 R can also be used in UPS Systems that provide less power to the slot The same MWTZE will be used for the new CS121 MINI SLOT so that less power consumption is needed in this case as well The MWT2D E is also equipped with a new 32 bit processor not shown picture The module MWT2D replaces the MWT2C of
2. 1995 2007 Generex GmbH Hamburg Germany Advanced User OK Cancel display while in SEARCH UPS Searching USB and Mode COM ports for connected indicates the UPS device current interface that is being searched Current port co hd GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 New UNIX UPSMAN Graphical configuration replaces CURSES UPS_CONF The configuration module based on the Curses programming language for the UNIX version of our serial USB UPS Management Software UPSMAN and RCCMD has not changed in 15 years However support for this platform has recently been abandoned by the new UNIX systems and this forces us to do the same Starting with CD 5 40 UPS_CONF will no longer be available and instead it will be replaced by JUPS CFG a JAVA based configuration tool These changes will also follow for RCCMD with the release of CD 5 41 or after February 2008 New JUPSCFG UPSMAN Configuration x Java Applet Window Device l System l Files Special Events Model Search UPS GE YH Series w serial v Location links Date of Battery Installation DD MM YYYY Device fdev ttySo0 w Baudrate 1200 w 0 Restore Factory Settings c 2001 2007 GENEREX GmbH Hamburg 5 6 34 Advanced User C 121 Scheduling function extended
3. Manual activation deactivation in Scheduler for EVENTS The CS121 has a new function that makes the monitoring and control of the UPS system easier This new CS121 Scheduler function enables users to select whether automated event actions that are normally triggered by critical situations e g power outages to be manually or automatically disabled Application example Conditions on certain days may require that a Shutdown be avoided even at the expense of completely draining the batteries On the other hand conditions on other days will allow for shutdowns when power outages occur Typical occasions for the use of this application are on days when companies and stock exchanges are facing deadlines to prepare their quarterly or year ending financial statements At such times avoiding system changes is imperative and in no case should operations in progress be impeded So during the day time between Monday and Friday for example all automated actions of the CS121 for power outages can simply be deactivated and set as activated at night and on weekends All EVENTS can be turned on and off manually by mouse click or using the appointment scheduler oo eee The EVENT configuration screen displays an overview of the statuses for all events GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 New Threshold values in the EVENT configuration C 121 and UPS
4. NEWSLETTER 12 2007 Overview 1 New Price Lists 2 New DOCU CD 3 New Products a Hardware b Software 4 CS121 Software Errors Software UNMS Il 5 SIEMENS Profibus Customizable network monitoring and management software 6 New GENEREX INTERNET PRESENCE Sesh ier a a complies electrical installation of a mobile 7 Discontinuation of Products alka eer R Less experienced users can also 8 Problem Solutions easily manage the system Complex system relationships are presented in a clearly structured overview Dear GENEREX Customers We announced the development of a number of new products in our May 2007 Newsletter that we would now like to present to you The CS121 based on the new Hyperstone Processor 32SX Also referred to at GENEREX as the HW131 starting with the production of the 06 2007 series is equipped with a COM 3 interface that can be used for connecting the BACS Battery Bus No firmware has been released for this series yet but it is already present on the market and has been installed in about 8000 UPS systems For these devices a firmware upgrade will soon be made available that can be used for monitoring batteries Starting in 2008 the CS121 models will be upgraded using the new HW131 and the production of all BUDGET models after 3 2008 will be upgraded with and additional 2 MB of flash memory and an additional 4 MB of RAM which will enable these devices to archive log entries for a lo
5. Korean French Italian Spanish Portuguese and Turkish Additional languages are in progress The current versions of the Quickstart Booklets are available on our Website under http www qenerex de manuals quickstart GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 New Products BACS Battery Analysis amp Care System The BACS System is composed of 3 system components a BACS Modules Module type depends on battery size and voltage b BACS WEBMANAGER as control unit and c Bus connection Bus cables are used for connecting the modules and BACS WEBMANAGER together New BACS C10 Module BACS MODULE C10 For 6 Volt and 12 Volt 7 3000Ah lead batteries Module size 64mm 50mm 25mm The new BACS C10 Modules are housed in casing made of durable synthetic materials that are easy to install inside of the battery cabinets The connections to the BACS WEBMANAGER are made using standard cables so that the assembly of special cables is not needed The BACS C10 System is dedicated to monitoring battery block status values For exact analysis every battery module has an integrated circuit for precisely measuring the internal resistance of each individual battery Should corrosion or sulfation increase the blocks internal resistance this will touch off an alarm In this matter alarm values can be adjusted to match the different battery types In contradiction to the
6. the listing is an error The new BACS C10 Modules do not include any cables If needed these components must be ordered separately New DOCU CD All of our products now include a German and English documentation CD ROM It contains a clear and complete collection of manuals for all of the GENEREX products The quick and simple production of the CD enables us to quickly provide our customers with documentation that covers all of the latest changes and updates In this way the contents of our manuals are able to reflect the most up to date information on our products Multilingual Quickstart Booklet Due to Europeanization and the multilingual aspects related to it all of our products CS121 SITEMANAGER lI SITEMONITOR lI SITESWITCH 4 and BACS WEBMANAGER include instead of an English user manual a set of Quickstart instructions in all of the major world languages This does not apply to OEM customers with their own user manuals These Quickstart instructions describe how to integrate the device into the network This includes a short description for setting up a BS ky eee BACY Manspement The latest version of the DOCU CD can be obtained online under the following link http www generex de manuals docu cd network shutdown with RCCMD and a selection of some of the other most important possibilities for using the device Currently the following languages are available German English Japanese Chinese
7. BACS C1 C7 System the BACS C10 System has no equalizing function The charging pulses of the individual battery are not regulated or balanced out This results in no heat being radiated from the unit which makes it possible to completely encase it Otherwise its functioning is identical The advantage of the BACS C10 Modules is that they can be used for 6V and 12V batteries within the range of 7 3000Ah The compactness of this module makes it very easy to install in the tightest spots and it emits no heat In reference to the listing error as stated above please note that delivery does not include the PWRCONO4 connection cable which must be ordered separately to match the size and cable lugs of the battery The bus cables have been standardized and no longer require any special tools but these cables must also be ordered separately and take into consideration the distance between the individual batteries Another advantage of this model is that it can be exchanged without having to disconnect the battery from the charging unit or UPS because its connections are completely insulated so that the module can easily be completely disconnected GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 New starting February 2008 BACS C20 and BACS C21 Modules BACS MODULE_C20 12 V with without Equalizing For 12Volt 7 300Ah lead batteries Module size 80mm 55mm 27mm
8. BACS MODULE C21 Large application range with without Equalizing For 2Volt 60 3000Ah 4Volt 40 1500Ah and 6V 12 800Ah lead batteries Module size 80mm 55mm 27mm The BACS C2X module has also been cased into a durable synthetic housing and made for easy installation The connections to the BACS WEBMANAGER are made using pre confectioned bus cables which makes the assembly of special cables as with the C1 module no longer necessary The BACS C2X Modules possess the same properties as the BACS C1 C7 System which includes the Equalizing function Using the bus system and all of the connected battery modules the BACS WEBMANAGER control unit gathers the voltage measurements of each battery and continuously calculates the optimal set charging values for each individual block in relationship to the overall system voltage The calculated set values are relayed over the data New Tip for New Customers UPS System Preparation for BACS For customers who are interested in eventually retrofitting their new UPS systems with the purchase of a BACS System but are not yet ready due to budget considerations or for other reasons can now easily and affordably prepare their systems for battery monitoring later The preparation for retrofitting with BACS or any other modern battery monitoring system is now possible for new installations Since retrofitting is usually considerably more expensive than an immediate installation batterie
9. MAN configurable threshold values for UPS devices Starting immediately all OEM customers in levels 1 4 will get the function Configurable Thresholds for their UPS devices in CS121 and UPSMAN free of charge Previously the function was made available only to OEM customers who had explicitly ordered this function After one year of exclusively reserving this functionality for such customers we will now make it available to all New other OEM customers as a free enhancement for their CS121 and UPSMAN products Threshold Events re eee Add Threshold Event Variable Batteryvoltage Direction lt v Threshold hajo New Threshold configuration parameter in this example a threshold is being set for an alarm defining a lower threshold value for the supplied voltage to the battery RCCMD Wizard New Functions The RCCMD Software is used for sending network shutdown commands and messages between different operating systems and networks The newest feature for the Windows version of RCCMD is that multiple instances of the service can be started While this type of service behavior is unusual under Windows it can certainly be applied effectively as is the case when RCCMD TRAPS are in use for example Using this method a RCCMD client can be used to monitor a maximum of 30 CS121 devices per RCCMD client process and relay messages when alarms occur So when 2 different RCCMD clients are running Certainly with
10. P mail generex gmbh de Sender E Mail Address team generen de Use Server Suthentication Account User Name Jteam HME Cancel Email configuration for RCCMD so incoming messages from a CS121 can be relayed by the RCCMD Client Configure Shutdown Sequence l x File E gdevstestishutdown bat Available Commands Current Sequence RCCMD shutdown relay to 192 168 202 36 RCCMD shutdown relay to 192 168 202 255 RCCMD shutdown relay to gx36 Quit Applications Log off user Shut down Windows 5 Power off Windows Restart Windows Quit Lotus Notes NOTEPAD EXE Quit Siemens SIMATIC Wait some seconds lt E RCCMD shutdown relay lt lt Description of Add custom application RCCMD shutdown relay Relays RCCMD shutdown command to another computer Enter IP address or hostname of the remote computer you want to shutdown Cancel_ Shutdown configuration for RCCMD and UPSMAN define a sequence of actions that are to be taken in the event of a Shutdown C 121 HW 131 Software Errors Important Customer Information C 121 HW 131 Software Errors V 3 65 3 75 Within the course of service discussions we discovered that certain firmware releases for our UPS Adapter Model CS121 HW 131 Market release mid 2006 caused errors that could eventually lead to malfunctioning in some cases This occurred only with the CS121 Models based on the HW 131 with Firmware versi
11. S location in Hamburg for monitoring many UPS devices for the A 318 319 and parts of the A 380 production facilities Autosearch for UPSMAN and C8121 The Search UPS function is not a basic feature that is included with all OEM versions of UPSMAN our serial UPS Management Software This is due to the vast list of UPS model types that our OEM customers support The more devices that are listed the longer the Search will take and the greater the risk will be that the search interferes with the UPS device that it is trying to detect The following pictures display how the UPS search looks and operates OEM customers wishing to implement the automatic UPS search function in their software must submit an evaluation of their ability to fulfill certain requirements that will also provide a basis for estimating an offer The estimated costs for this service will be primarily based on the scope of work Please contact us for a consultation if you are interested in implementing this feature E l SEARCH Device UPS button in ne ee UPSMAN Search UPS for starting the Location POO automated Power VAJ o Hold time m 10 X identification of UPS models Load VA 500 Recharge time h E Date of Battery Installation DD MM Anr 0210 2 conne cted to Device COM and USB Port lt COM1 gt F Baudrate Address Listen Port 5769 Licencekey 30EM4x 1445844 UPS ID Reset to Factory Settings
12. S121 MINI Slot also lies between BUDGET and full featured version in price We are quite sure that these are currently the best devices available on the market for these UPS Models DIP Schalter A Fla tinenstecker A 5 imm IIll 10 9mm GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 New UNMS II with UPS Type Transfer Automatic recognition of foreign manufactured UPS devices Since its introduction it has always been necessary to specify which non OEM UPS systems would be used in addition to the manufactures models when ordering the individually customizable UNMS II UPS Network Monitoring and Management System This will now become an issue of the past Starting in February 2008 with the coming of Version 1 3 UNMS II will work with UPS systems from varying manufactures Previously this type of operation could only be implemented using SNMP RFC 1628 compatible devices but other CS121 or UPSMAN managed network UPS from other OEM customers were excluded Now on start up the UNMS Il recognizes the configuration of other devices in the network independent of manufacture type and can New monitor all CS121 devices or systems connected to them Naturally this only applies to the licensed versions of UNMS Il As before the free version works only with UPS devices of the specific manufacture and CS121 or UPSMAN UNMS II at the AIRBU
13. all the newest firmware This Flashwizzard prompts the user upon recognition of the corresponding Hardware Software combination to shortly interrupt power supply to the device Either by unplugging the CS121 power cable or by pulling out the UPS Slot to insure a safe and complete execution of the update process In case an update cannot be successfully completed our support will be able to lend you further assistance in completing the process once you send in the configuration file upsman cfg which is created using the Backup Configuration function GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 SIEMENS Profibus New C 121 PROFIUS ADAPTER The full featured CS121 models SC L R F are equipped with a RS232 interface on COM2 that can output all UPS data via MODBUS The new SPI3 PROFIBUS Converter can be attached to these COM2 connections and convert the data into PROFIBUS To use the SPI3 Profibus Converter it is not necessary to integrate the corresponding CS121 L SC R into an Ethernet network The CS121 L SC R converts the serial protocol of the device that is connected to COM 1 into Modbus RTU PROFIBUS Umsetzer PROFIBUS SNMP WEB MANAGER CS 121 protocol which is then read and converted by the SPIS PROFIBUS The SPI3 PROFIBUS Converter has been especially programmed for direct use with the CS121 NO other RS232 PROFIBUS data dev
14. enerex de NEWSLETTER 12 2007 Discontinuation of old products MULTI IQ The MULTI IQ parallel connection Multiplexer has been discontinued Due to the CS121 PIPE THRU function demand for this device has gone back drastically To manage UPS systems BACS C5 and BACS C7 that are located in separate networks every CS121 full featured COM2 connection can be used to couple a second third or even up to 5 devices in a row In effect this has rendered the MULTI IQ practically obsolete The C2x successor is coming in February 2008 The BACS Module C 5 was already discontinued back in the middle of 2007 the BACS C7 module will also be replaced at the beginning of February 2008 Support for the C5 and C7 Modules will continue e g Firmware upgrades BACS Viewer and the likes however new installations will only be equipped with BACS C1 C10 C20 and C21 BACS WEBMANAGER Type I The BACS WEBMANAGER II is coming in May 2008 800 BACS WEBMANAGER units have been sold to date which is few in comparison to the CS121 but a lot in the area of battery management The BACS WEBMANAGER Type based on the CS121 will be continued until Spring 2008 afterwards it will be succeeded by the BACS WEBMANAGER II which will be based on the higher performing new CS151 platform Problem Solutions Problems with the CS121 R and AROS RIELLO Slots Customer support cases have revealed that the slots in the UPS devices of the
15. es published by users of discussion boards guest books or mailing lists provided on his page 3 Copyright The author intended not to use any copyrighted material for the publication or if not possible to indicate the copyright of the respective object The copyright for any material created by the author is reserved Any duplication or use of objects such as diagrams sounds or texts in other electronic or printed publications is not permitted without the author s agreement 4 Privacy policy If the opportunity for the input of personal or business data email addresses name and addresses is given the input of these data takes place voluntarily The use and payment of all offered services are permitted if and so far technically possible and reasonable without specification of any personal data or under specification of anonymized data or an alias The use of published postal addresses telephone or fax numbers and email addresses for marketing purposes is prohibited offenders sending unwanted spam messages will be punished 5 Legal validity of this disclaimer This disclaimer is to be regarded as part of the internet publication which you were referred from If sections or individual terms of this statement are not legal or correct the content or validity of the other parts remain uninfluenced by this fact GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007
16. ices is compatible This product includes with delivery a special DBSUB9 male to Mini 8 connection cable for the connection between the CS121 COM2 and SPI3 PROFIBUS The Connection Adapter cables for the device that is to be connected to the other end of the PROFIBUS is not included since only specific cables can be used for different devices A My MN USV New GENEREX Internet Presence We would like to introduce customers to our completely redesigned Web site that has a totally new layout This will present our products and services more clearly in a visual context that has greater appeal Our customers will have the same possibilities as before to access areas of service for obtaining links and data for their websites e g Downloads For certainty we do ask that you check all current links to confirm their validity We have listed and tested all of our own links to our OEM customers www generex de Its all new so please call our attention to any errors that you notice and we would also appreciate any constructive suggestions see g es ee a s a Dmg e ajam Ar ime G iliem e a Jumaa i E n Qi E ims Cee Less jasia s dee o Beeps ies alol l 4 Protuct Range a a ba te a a ro 4 Mum SP amt fd Ra geri m S ee ee amd mi 3 2 ae ee ee TT t a Lim C F eee T eee ed GENEREX GmbH Germany Hamburg generex generex de http www g
17. nagement on the market is simpler or more economical GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 New starting May 2008 BACS WEBMANAGER II Completely re designed control unit with many new functions Modern control unit for the BACS C10 and C2x modules and for network based UPS and facility management Feature overview of new model Monitor each battery individually Connections for the simultaneous monitoring of UPS and other devices with serial connections e g SENSORMANAGER SM_T_ COM etc Connections for auxiliary environmental sensors e g temperature humidity etc Automatic calculation of set point and threshold values for all parameters e g internal resistance voltage and temperature cycles etc Determination and evaluation of battery conditions during charging discharging and recovery phases in all areas Graphical evaluation of data for observing and predicting battery failures of individual batteries based on their charging and discharging performance Alarm notifications on LC panel display and sounding alarm Alarm relaying to users by network or modem via email SNMP and RCCMD WEB Server for simple configuration and status display LC panel displays current status Integrated programs for easily assigning C2x module addresses Integrated distribution box no more extra converter necessary
18. nger time and add new functions In January 2008 a new CS121 MINI SLOT will be released that is a combination of the CS121 BUDGET SLOT and the professional CS121 SC SLOT versions with the inclusion of a COM2 but no AUX COM3 connection The CS121 MINI Slot has been designed for the Phoenix Tec Centrallion UPS systems and for other derivatives of these models from other manufactures The new BACS C2x Series will soon be ready for release and the BACS C2x Modules will already be delivered to a selection of customers in spring 2008 This will be the newest generation of battery management sensors and with that the most economical and the most professional solution on the market We wish you a successful conclusion of this year and a great start into 2008 GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 New Price Lists The current GENEREX price list for 10 2007 has already been sent to you separately It contains information about our newest products and current prices Please forward this price list to your purchasing department or authorized personnel All previous price lists are no longer valid Send an email to newsletter generex de and notify us if you need the current price list and we will act promptly to provide you with the needed information LISTING ERROR Page 30 31 Product code PWRCONO4 for BACS Module C10 The specification of the PWRCONO4 cable in
19. on 3 65 to 3 75 None of the older HW 121 Models from the years 2000 2005 were affected The error occurred predominantly in networks with more modern switches e g CISCO HP Procurve and similar Multicasting switches or in networks that are more often subjected to considerably higher than average loads for long periods of time Such network loads were causing the devices Watchdog to trigger Rebooting The system reboot would malfunction during the start up phase when being flooded with broadcasts This error would be announced by the sudden disappearance of the device from the network A manual restart would only temporarily remedy the problem until the next occurrence of this error It is somewhere between moderately and highly probable that this error will occur with the CS121 HW 131 yet the exact conditions under which this error arises can not be ascertained this can happen directly after starting after several months of operation or practically never Nevertheless we urgently recommend that all of our customers install the newest firmware available from our website for these devices Even if no such errors have occurred till this date we must insist that this advice be followed We regret any possible inconveniences caused by this situation and will gladly assist you with any further help or information needed in this matter The new Firmware also contains an improved Flashwizzard that helps you to more easily inst
20. one individual license key per process 60 UPS devices and be monitored and so on This can be used to create an extensive UPS monitoring system even without the use of any graphics a simple text box Enter IP address or hostname of the remote computer you want to shutdown with RCCMD Configuration of the RCCMD relay This turns the RCCMD Client into a RCCMD Server that can shutdown several 100 RCCMD Clients simultaneously much faster than a CS121 at the same task can be used to adequately describe the occurrence of any UPS problem Wri Client installation g iol x IP address list of all RCCMD servers that are allowed to send a shutdown command to this client no entry means every server 192 168 202 36 192 168 202 51 192 168 202 25 Delete Address Edit Address Bind IP 192 168 202 36 Browse for IP on Port 6003 RCCMD ver 4 0 0 5 lt Back _New gt Cancel Define which IP addresses are to be monitored and configure the network card that is to be used for this purpose Select network adapter X The following network adapters were found on the computer Select one of it for RCCMD to listen on Cancel Selection and definition of the RCCMD network card lists GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 E Mail settings Enable E Mail Client Outgoing Server SMT
21. rex de Internet http www generex de Internet http www generex co kr You are receiving this Newsletter because you have signed up to our regular Newsletter you have ordered products or service from GENEREX so that we suppose that you may be interested in further information If you do not want to receive further Newsletters please unsubscribe from our mailing system at http www generex de newsletter subscription Disclaimer 1 Content The author reserves the right not to be responsible for the topicality correctness completeness or quality of the information provided Liability claims regarding damage caused by the use of any information provided including any kind of information which is incomplete or incorrect will therefore be rejected All offers are not binding and without obligation Parts of the pages or the complete publication including all offers and information might be extended changed or partly or completely deleted by the author without separate announcement 2 Referrals and links The author is not responsible for any contents linked or referred to from his pages unless he has full knowledge of illegal contents and would be able to prevent the visitors of his site from viewing those pages If any damage occurs by the use of information presented there only the author of the respective pages might be liable not the one who has linked to these pages Furthermore the author is not liable for any postings or messag
22. s can now be equipped with the necessary cabling at a low cost from the very beginning Offer your customers the UPS System Preparation for BACS Analogous to new car purchase options customers can now order pre cabled batteries Later the BACS retrofit will be child play snap on finished The small expense involved in attaching the cables to bus to the corresponding individual modules Then each battery module independently regulates the voltage to its corresponding battery using an integrated bypass The BACS C2X Modules are available for 2V 4V 6V and 12V lead batteries within 7 3000Ah The market introduction for the BACS C20 modules will be geared exclusively towards the large market for lead based 12V batteries With the entrance of the C21 module starting in April 2008 the C10 will become obsolete and replaced by the C21 The C1 module which is used for smaller batteries up to 12Ah will remain in production After February 2008 the C5 and C7 modules will only be made available for replacement orders batteries from the beginning are only a fraction of what labor will cost when the users decide to upgrade later if these preparations have not been made The PWRC2xCONx power supply cables 15 cm 25 cm and 40 cm are listed in the GENEREX price list and are available immediately This will open up a whole new range of opportunities to you and your customers for generating more turnovers No other battery ma
23. se manufactures have different power supplies Smaller UPS devices 10 20kVA provide too little power to the slot for the CS121 R The larger models gt 40kVA do not have this problem For smaller devices it then becomes necessary to use the CS121 L or BL which have their own power supply This difficulty will soon be corrected once the new CS121 R models based on the MWT 2E with reduced power consumption see page 6 become available At this time it will again be possible to use the CS121 R with smaller UPS GENEREX GmbH Germany Hamburg generex generex de http www generex de NEWSLETTER 12 2007 GENEREX Headquarters in Hamburg GENEREX GmbH Bank account Brunnenkoppel 3 HAMBURGER SPARKASSE 22041 Hamburg BLZ 20050550 GERMANY Konto Nr 1201121470 SWIFT HASPDEHHXXX Tel 49 40 2269291 0 Reception IBAN DE 582005055012011214 70 Fax 49 40 2269291 10 VAT ID No DE 811668125 GENEREX Business Locations Production Management UNIX Development Asia Marketing amp Support GENEREX GmbH GENEREX GmbH GENEREX GmbH Asia Pacific Stettiner Str 23 Obere Weinsteige 66 9F Kolon techno valley Kasandong D 37412 Herzberg D 70597 Stuttgart Keumchonku 153 770 Seoul Korea Tel 49 0 40 2269291 25 Tel 49 0 711 3910823 Tel 82 50 22692910 Fax 49 0 40 2269291 10 Fax 49 0 711 3916694 Fax 82 50 22692911 Email a wassmann generex de Email m herrmann generex de Email jonson generex de Internet http www gene
24. the BACS WEBMANAGER and SITEMANAGER II This doubles the memory of both devices which will make it possible to extend both of their functionalities All new deliveries will be based on New C 121 as MINI Slot the memory extended models of MWT2D or MWT2E please take notice of this when updating older products by selecting the correct extensions The new MWTs are indicated by the addition of 4MB to their name endings e g BACS 4MB MWT 2D E Mini Adapter for the monitoring and control of UPS Systems Starting in January 2008 the new CS121 as Mini Slot will be available The CS121 Mini Slot will be a combination of the CS121 BUDGET and the CS121 That means that it will have a COM 2 like the professional CS121 for connecting a SENSORMANAGER individual sensors like the SM_T_COM temperature sensor the new SM_T_H_COM combo sensor for temperature and humidity Modem Pipe_Thru and the likes however it will not have an AUX or COM3 connection That way the CS121 Mini can also be used with such UPS devices like the Phoenix TEC and the Centrallion that use such a format In addition it can also be used in all types of copies of such UPS devices that are imported from China and India The device is operational within a wide range power supplies It is suitable for use with UPS Systems that provide as little as 1 3 Watt minimum to the slot connection The upper limit value is 30 Volts The C
Download Pdf Manuals
Related Search
Related Contents
Users Manual 4輪ドリーカメラスタンドセット Bedienungsanleitung Harman Kardon Go + Play II 3D Printing with Ultimaker2, User Guide Friedrich BRO412W1A User's Manual 取扱説明書 - ご家庭のお客さま/大阪ガス Manual Contraste de Cargos ASUS M70AD I8553 User's Manual Copyright © All rights reserved.
Failed to retrieve file