150 PSI HIGH-FLOW AIR SOURCE KIT

image

Contents

1. b Drain water from tank by opening the drain cock drain valve c If drain cock is plugged release all air pressure from tank remove drain valve and clean then reinstall d After condensate has been drained close the drain cock IMPORTANT Observe air tank Date of Manufacture stamped on tank leg Replace air tank 2 to 5 years from date air tank was first used or use the date of manufacture as reference Your adherence to air tank draining guidelines will determine the replacement date of your air tank RUSTED TANKS CAN FAIL CAUSING EXPLOSIONS OR FATAL INJURIES Discard tank immediately if tank is rusted NOTE When using a safety pressure relief valve point the safety pressure relief valve away from your body Use the pull ring on the safety relief valve open the relief valve to vent any pressure inside the tank before attempting to service tank USER MANUAL 150 PSI HIGH FLOW AIR SOURCE KIT COMPRESSOR APPLICATION GUIDE ABOUT COMPRESSOR DUTY CYCLE Compressor Duty Cycle refers to amount of time a compressor can be operated in a given time period at 100 PSI amp ata standard ambient temperature of 72 F Duty Cycle is commonly expressed as Compressor On Time Compressor On Time Off Time As an example a compressor that is rated for 20 duty cycle means that compressor can be operated at 100 PSI 72 F for 8 Minutes and rested for 32 Minutes 8 min on 8 min on 32 min off 20 Duty Cycle DUTY CYCLE
2. shaft 3 Repair or replace compressor 3 Cylinder or piston ring is worn CAUTION NEVER DISASSEMBLE COMPRESSOR WHILE COMPRESSOR IS PRESSURIZED 150 PSI HIGH FLOW AIR SOURCE KIT LIMITED WARRANTY VIAIR Corporation warrants this product when properly installed and under normal conditions of use to be free from defects in workmanship and materials for a period of one year from its original date of purchase To receive warranty service or repair please contact VIAIR Corporation Returns should be made within one year of the date of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain RGA fax a copy of your receipt to 949 585 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE Your Vital Air Source 15 EDELMAN e IRVINE CA 92618 TEL 949 585 0011 FAX 949 585 0188 www viaircorp com USER MANUAL
3. REFERENCE CHART DUTY CYCLE 100PSI 72 F MINUTES ON OFF 15 6 Min On 34 Min Off 17 7 Min On 30 Min Off 20 8 Min On 32 Min Off 22 9 Min On 30 Min Off 25 10 Min On 30 Min Off 30 13 Min On 30 Min Off 33 15 Min On 30 Min Off 100 Continuous Duty ABOUT RATED WORKING PRESSURE To ensure trouble free service life of your compressor always operate compressor within rated working pressure of the compressor Never use a pressure switch with a higher cut off pressure than compressor s rated working pressure SPECIFICATIONS 280C AIR COMPRESSOR Motor Voltage 12 Volts Max Current Consumption 16 Amps Recommended Fuse 30 Amps Motor Type Perm Magnetic Horse Power 1 4 Max Working Pressure 150 PSI Max Duty Cycle 72 F amp 100 PSI 30 Minutes On Off 72 F amp 100 PSI 13 On 30 Off Continuous Use 72 F amp 40 PSI 40 Minutes Max Restart Pressure 200 PSI Max Ambient Temperature 158 F Min Ambient Temperature 40 F Auto Reset Thermal Protection Yes USER MANUAL PROBLEM Tank pressure drops when i TROUBLESHOOTING GUIDE POSSIBLE CAUSE S Loose drain cock CORRECTIVE ACTION 1 Tighten drain cock compressor s shut off 2 Check valve leaking 2 Replace check valve or compressor s 3 Loose connections 3 Check all connections with soap and water solution and tighten Compressor runs continuously and 1 Excessive air usage 1 Decrease air usa
4. Your Vital Air Source 150 PSI HIGH FLOW AIR SOURCE KIT 30 Duty Compressor on 2 0 Gallon Air Tank PART NO 20005 IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE CE Only Compressor USER MANUAL is CE Certified 150 PSI HIGH FLOW AIR SOURCE KIT IMPORTANT SAFETY INSTRUCTIONS CAUTION To reduce risk of electrical shock or electrocution Do not disassemble Do not attempt repairs or modifications Refer to qualified service agencies for all service and repairs Do not use this product in or area where it can fall or be pulled into water or other liquids Do not reach for this product if it has fallen into liquid Use this compressor with 12 volt DC systems only This product should never be left unattended during use WARNING To prevent injuries Never allow children to operate this compressor Close supervision is necessary when this compressor is being used near children This compressor will become very hot during and immediately after use Do not touch any part of this compressor with bare hands other than the ON OFF switch during and immediately after use Do not use this product near flames or explosive materials or where aerosol products are being used Do not operate this product where oxygen is being administered Do not pump
5. anything other than atmospheric air Never use this product while sleepy or drowsy Do not use any tools or attachments without first determining maximum air pressure for that tool or attachment Never point any air nozzle or air sprayer toward another person or any part of the body This air compressor is equipped with an Automatic Reset Thermal Protector and can automatically restart after the thermal protector resets Always cut off power source when thermal protector becomes activated Wear safety glasses or goggles when operating this product Use only in well ventilated areas USER MANUAL 150 PSI HIGH FLOW AIR SOURCE KIT INSTALLATION Please read and follow the Installation Instructions carefully to avoid injury or damage to the compressor or your vehicle Selecting a Mounting Location The selection of a proper mounting location for your air source kit will help ensure a long and trouble free service life Please pay close attention to the following guidelines 1 Select a FLAT UPRIGHT AND SECURE location where the air source kit can be mounted To maximize air compressor performance locate compressor as CLOSE TO THE BATTERY as possible so that length of positive lead wire required is at a minimum Choose mounting location that is as cool as possible and AWAY FROM HEAT SOURCES The cooler the ambient temperature the less chance the compressor will overheat The compressor is mo
6. ce connect and test compressor system by running the compressor for a short time to build up pressure in your air tank Once air pressure reaches preset cut out pressure of your pressure switch 100 PSI cut on 145 PSI cut off the compressor will shut off automatically Inspect all air line connections for leaks with soap and water solution If a leak is detected the air line may not be cut squarely or pushed all the way in Tighten connections if needed USER MANUAL 150 PSI HIGH FLOW AIR SOURCE KIT OPERATING INSTRUCTIONS 1 IMPORTANT Always operate the compressor BELOW the MAXIMUM PRESSURE RATING of the compressor Please refer to Application amp Specifications Sections of this manual for details 2 Always observe the MAXIMUM DUTY CYCLE of the air compressor Refer to Compressor Applications and Specifications Section of this manual for details Operation exceeding maximum pressure ratings and or duty cycle will result in damage to air compressor 3 Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR This feature is designed to protect the air compressor from overheating causing permanent damage to your air compressor The thermal overload protector will automatically cut off power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use 4 Should at any time during use your air compressor automatically shuts off
7. do not attempt to restart air compressor Turn power switch to the air compressor to the OFF position The automatic thermal overload protector will automatically reset when internal temperature of the air compressor drops below safe levels After allowing air compressor to cool off for about 30 minutes you can safely resume use of the air compressor by turning on the air compressor 5 To prevent discharge of your vehicle s battery we strongly recommend that you keep the vehicle s engine running while using the air compressor Compressor performance is enhanced when operating compressor with vehicle s engine running 6 IMPORTANT ONLY OPERATE THE AIR COMPRESSOR IN WELL VENTILATED AREAS USER MANUAL 150 PSI HIGH FLOW AIR SOURCE KIT AIR TANK PRECAUTIONS IMPORTANT a The air source kit air tank is rated for 150 PSI maximum working pressure Do not overfill Overfilling may result in death or serious injury b Tank is not to be used as a breathing device c Always wear ANSI approved safety glasses when operating air tank d Bleed pressure from tank after each use and before servicing or adding attachments e Use only attachments or tools rated for 150 PSI working pressure or less DRAIN TANK OFTEN TO REMOVE CONDENSATE FAILURE TO DRAIN TANK WILL ALLOW TANK TO RUST INTERNALLY a To remove any accumulated condensation inside the tank bleed pressure from tank until pressure is approximately 5 PSI to 20 PSI
8. ge air flow lower than normal 2 Loose connections 2 Check all connections wit soap and 3 Worn piston ring or inlet valve water solution and tighten 4 Clogged air filter element 3 Repair or replace compressor 4 Replace air filter element Compressor runs continuously causing 1 Bad pressure switch 1 Replace pressure switch safety valve if equipped to open 2 Defective safety valve 2 Replace safety valve Excessive moisture in discharge Excessive water in air tank Drain tank tilt tank to drain 2 High humidity Drain tank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch 1 Make sure compressor switch is ON in OFF position 2 Disconnect compressors from power source 2 Blown fuse replace fuse Refer to Specifications section for 3 Motor overheats correct fuse amperage 4 Faulty pressure switch 3 Let compressors cool off for about 30 Minutes to allow thermal overload switch reset 4 Replace pressure switch Thermal overload protector 1 Lack of proper ventilation or 1 Move compressor to well ventilated area cuts out repeatedly ambient temperature too high or area with lower ambient temperature 2 Compressor valves failed 2 Repair or replace compressor Excessive knocking or rattling 1 Loose mounting bolts 1 Tighten mounting bolts 2 Worn bearing on eccentric or 2 Repair or replace compressor motor
9. isture amp splash resistant but NOT WATERPROOF Do not mount air source kit in locations where the unit is likely to come in contact with water If it is necessary to mount the air compressor further away from the battery such as inside your vehicle or in the bed of your pickup use a minimum 8 10 AWG positive lead wire for remote installation Do not mount air source kit near areas where flammable liquids are stored USER MANUAL 150 PSI HIGH FLOW AIR SOURCE KIT MOUNTING AND WIRING 1 2 Disconnect ground cable from vehicle s battery Temporarily position the air source kit in the location where it will be mounted Route ground wire to the negative post of the battery or to an appropriate grounding point and cut ground wire to length as needed Mount air source kit at tank leg mounts with the four grommets and four sets of bolts nuts washers and locking washers provided Use of thread sealant is recommended Route 3 8 inch I D air line from the 1 2 inch tank port to a 3 8 inch compression fitting and make your air line connection Tighten compression fitting nut securely using a wrench Connect ground Black wire to a clean ground preferably a chassis ground and secure with a self tapping screw Connect positive Red lead wire from pre installed pressure switch to a fuse holder 25 amp minimum Once the kit is properly fused as close as possible to the power sour