1. Read Fames MECHANICAL DIMENSIONS ORDER CODE ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY PRODUCTS AND RELATED DOCUMENTS ADFweb com Srl IT31010 Mareno Treviso 9 ODMNNADAWNNNNNGA en ee oe ee ee N NI NJ O OD O07 071 01 BW WN FR User Manual NMEA 2000 Ethernet Document code MN67223 ENG Revision 1 001 Page 2 of 17 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is gt Updated gt Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates To obtain the updated documentation for the product that you own note the Document Code Abbreviated written Doc Code on the label on the product and download the updated from our web site www adfweb com download REVISION LIST Revision Date Author Chapter Description 1 000 09 07 2010 Dp All First release version 1 001 12 02 2013 Nt All Added new chapters WARNING ADFweb com reserves the right to change information in this manual about our product without warning
2. ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 iNi User Manual NMEA 2000 Ethernet Document code MN67223_ENG Revision 1 001 Page 3 of 17 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device are required for each individual application legal and safety regulation The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instrument can represent a potential hazard if they are inappropriately installed and operated by personnel untrained These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is danger for people to seri
3. Section Update Via Serial Fig 6 In order to load the parameters or update the firmware in the gateway follow these instructions VV v VVVV YV VVV V At this point the configuration firmware on the device is correctly updated Turn off the device Connect the Null Modem cable from your PC to the gateway Insert the Boot Jumper see the Fig 1 for more info Turn on the device Check the BOOT Led It must to blink quickly See the Fig 1 for more info Select COM port and press the Connect button Press the Next button Select operations you want to do Can select only Firmware or only Project or both Press the Execute update firmware to start the upload When all the operations are OK turn off the device Disconnect the Boot jumper Turn on the device Figure 6 Update Via Serial windows ADFweb com Srl IT31010 Mareno Treviso User Manual NMEA 2000 Ethernet Document code MN67223 ENG Revision 1 001 Page 11 of 17 Update Firmware from Serial RSZ Wy Follow this step to update the HD67213 from RS232 Turn OFF the Device Insert the Boot Jumper see the manual Turn ON the Device Check the BOOT led It must blink quickly ce Update Device Options z Firmware T Read Firmware when finish Zil Project Zil Read Project when finish Execute update firmware _SW67213 Serial Update _ i5 Ver 1 000 INIT Waiting j FIRMW
4. DIN Power Supply 110V AC 50 60Hz 12 V AC Order Code AC34104 European Input Power Supply 230V AC 50Hz 12 V DC ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 iNi User Manual NMEA 2000 Ethernet Document code MN67223_ENG Revision 1 001 Page 16 of 17 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document content is a recurring audit For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate a collection systems m his symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it Should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and human health which could otherwise be caused by inappr
5. send Byte Number 2 has got a value greater than one the next frame is composed from byte 3 to byte 15 and so for all the frames The response is composed by only one byte It can have two values e 0x00 No Errors e Qx0O1 Parameter Error Example We want to write two frames with the following characteristics Frame 1 Priority 6 Data Page 0 PGN FECA Source Address 1 Data 0x0102030405060708 Frame 2 Priority 6 Data Page 0 PGN FFCA Source Address 2 Data 0x1122334455667 788 So the string of hexadecimal numbers is REQ 02 01 06 O0 FE CA 01 01 02 03 04 05 06 07 08 06 00 FF CA 02 11 22 33 44 55 66 77 88 RES 01 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 iNi User Manual NMEA 2000 Ethernet Document code MN67223_ENG Revision 1 001 Page 14 of 17 Industrial Electronic Devices Read Frames For reading Data it is necessary to have a map in the RAM memory that contains the Data that passing in the bus This map is implemented in the Compositor SW67223 but it has some standard address given by the software It is possible to see this map in Fig 5 The Bytes that composed the request are these Byte Number Description _ O Z O O 1 Read Write Identifier Read 0x01 Write 0x02 Starting Address Hi S Starting Address Hi 3 Starting Address Lo 4 Number of Byte to read Hi 5 Number of Byte to read Lo The B
6. the PGN of the data you would to read from Ethernet to NMEA 2000 it is an identifier In the field Source Address insert the address of the device that send the frame If the field Multi Packet is checked the Transport Protocol is enabled for the frame otherwise is disable If the field Fast Packet is checked the frame could use the Fast Packet Protocol functions In the field StartByte insert the Start Byte of the Transport Protocol Insert a value only if the Multi Frame is enabled In the field N Byte insert the number of bytes that composed the Transport Protocol Insert a value only if the Multi Frame is enabled If the field Cancel Data is checked the data in the frame will be erased after the TimeOut Data is expired In the field Mnemonic the description for the frame is defined ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Cancel Data Mnemonic l ja o OxFECA Ox01 O i 20 2 lo OxF003 Ox01 F C E 3 lo OxFEBA 0x01 i 10 a o C CO C 5 O CI E 6 ad O O 7 O E E IG O E O 9 F ud ll 10 E E CI 1i a adl L 12 F udi M 13 O C E User Manual NMEA 2000 Ethernet Document code MN67223_ENG Revision 1 001 Page 10 of 17 Receive NMEA2000 Frame Can0 ModBus Figure 5 Receive NMEA2000 window AL Industrial Electronic Devices UPDATE DEVICE VIA SERIAL
7. 0438 30 91 31 iV User Manual NMEA 2000 Ethernet Document code MN67223 ENG Revision 1 001 Page 7 of 17 Industrial Electronic Devices CONFIGURATION You need Compositor SW67223 software on your PC in order to perform the following gt Define the parameter of the NMEA 2000 bus gt Define the parameter of the Ethernet To configure the Gateway use the available software that runs with Windows called SW67223 It is downloadable on the site www adfweb com and its operation is described in this document Step 1 b New project ay Open project When launching the SW67223 the right window appears Fig 3 i Step 3 a Receive NMEA Step 4 a Update Device Ser www ADFweb com Figure 3 Main window for SW67223 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 iV User Manual NMEA 2000 Ethernet Document code MN67223_ ENG Revision 1 001 Page 8 of 17 Industrial Electronic Devices NEW PROJECT OPEN PROJECT The New Project button creates the folder which contains the entire device configuration A device configuration can also be imported and exported gt To clone the configurations of a Programmable NMEA 2000 to Ethernet Gateway in order to configure another device in the Same manner it is necessary to maintain the folder and all its contents gt To clone a project in order to obtain a different version of the project it is sufficient to duplicate the projec
8. ARE Waiting PROJECT Waiting INFO www adfweb com Phone 39 0438 30 91 31 iV User Manual NMEA 2000 Ethernet Document code MN67223 ENG Revision 1 001 Page 12 of 17 Industrial Electronic Devices CHARACTERISTICS OF THE CABLES The connection at Ethernet socket must be with a Ethernet Cable with a RJ45 Plug The connection from RS232 socket to a serial port example one from a personal computer must be made with a Null Modem cable a serial cable where the pins 2 and 3 are crossed It is recommended that the RS232C Cable not exceed 15 meters NULL MODEM CABLING Ss Te N N m 00 t oO Ww gt n CABLE CABLE Side A Side B FEM FEM ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 iNi User Manual NMEA 2000 Ethernet Document code MN67223_ENG Revision 1 001 Page 13 of 17 Industrial Electronic Devices ETHERNET PROTOCOL This protocol is able to read and write frames in the NMEA 2000 net Write Frames The transmission is very simple it require only what are the packets to send In a single request it is possible to write at maximum 19 frames in the NMEA 2000 net The Bytes that composed the request are these Byte Number Description _ _ o Z o Read Write Identifier Read 0x01 Write 0x02 Number of frames to send o 6 males A single frame is composed by 13 bytes byte 3 to byte 15 Now if the Number of frame to
9. User Manual NMEA 2000 Ethernet Document code MN67223 ENG Revision 1 001 Page 1 of 17 Industrial Electronic Devices User Manual Revision 1 001 English NMEA 2000 Ethernet Converter Order Code HD67223 A1 HD67223 B2 for Website information www adfweb com Product HD67223 Al1 www adfweb com Product HD67223 B2 for Price information HD67223 Al HD67223 B2 www adfweb com Price HD67223 Al www adfweb com Price HD67223 B2 Benefits and Main Features ae For others Converter Adapter eS RS232 RS485 Mountable on Rail DIN gt See also the following link TCP UDP protocols changeable with software a i USB RS485 Easy to use software configuration A a lening link i www adfweb com Product HD67119 Industrial temperature range 40 C 85 C 40 F 185 F Do you have an your customer protocol See the following link www adfweb com Product HD67003 Do you need to choose a device do you want help Ask it to the following link www adfweb com Cmd helpme ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT CONNECTION SCHEME CHARACTERISTICS POWER SUPPLY CONFUGURATION USE OF COMPOSITOR SW67223 NEW PROJECT OPEN PROJECT SET COMMUNICATION RECEIVE NMEA UPDATE VIA SERIAL CHARACTERISTICS OF THE CABLES ETHERNET PROTOCOL Write Frames
10. first a message with PGN OxFECA after it would send a Transport Protocol frame for sending the alarms If this frame arrives within the mS write in the box the frame with OxFECA is discarded and the Transport Protocol frame is held Otherwise the frame with PGN OxFECA is hold The means of the fields for Ethernet are VVV WV ADFweb com Srl IT31010 Mareno Treviso In the field IP ADDRESS insert the IP address In the field SUBNET Mask insert the Subnet Mask In the field Port insert the number of port If the field TCP is checked the Ethernet protocol used is the TCP otherwise if the field UDP is checked the Ethernet protocol used is the UDP SET COMMUNICATION INFO www adfweb com NMEA 2000 Ethernet Revision 1 001 Page 9 of 17 NMEA2000 Baud rate 250 i A CobDID 1iBit ae ee ee ee CAN Bus 2 0B CobID 29Bit TimeOut Data Sec jos Peer to Peer Filter FECA so ms Ethernet IP ADDRESS SUBNET Mask SO TCP F UDP Figure 4 Set Communication window Phone 39 0438 30 91 31 AL Industrial Electronic Devices RECEIVE NMEA By pressing the Receive NMEA button from the main window for SW67223 Fig 3 the window Receive NMEA 2000 Frame appears Fig 5 The means of the fields are gt gt In the field Data Page insert the Data Page in the NMEA 2000 protocol is O or 1 In the field PGN insert
11. opriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or RoHS 2002 95 EC CE MARKING The product conforms with the essential requirements of the applicable EC directives ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 iNi User Manual NMEA 2000 Ethernet Document code MN67223_ENG Revision 1 001 Page 17 of 17 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following 1 Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping c
12. osts shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate PRODUCTS AND RELATED DOCUMENTS Part Description URL HD67118 Converter RS232 to RS485 Isolated www adfweb com Product HD67118 HD67119 Converter USB 2 0 to RS485 Isolated www adfweb com Product HD67119 HD67007 Gateway Modbus TCP Server to RTU Master www adfweb com Product HD67007 HD67010 Gateway Modbus TCP Client to RTU Slave www adfweb com Product HD67010 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31
13. ous injury or death and or the possibility A of damage CE CONFORMITY The declaration is made by us You can send an email to support adfweb com or give us a call if you need it ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 iV User Manual NMEA 2000 Ethernet Document code MN67223_ ENG Revision 1 001 Page 4 of 17 Industrial Electronic Devices CONNECTION SCHEME Jumperi OV Ground V Positive wire Termination NMEA2000 Line E Opame 120 ohm 12 VAC min 8v max 19v 4 VA 24 VDC min 8v max 35v 4 Watt HO High wire ShlO Shield to Isolated Ground Connector3 LO Low wire Ethernet Port aa RJ45 Plug OV v HO Shio LO Led3 Green Link Ethernet Port RS232 D SUB9 Male A Programmation Port To connect the device to the COM port of a PC in order to set it you have to use the programming cable AC34107 Or a cable made as showed here HO Shio LO Jumper2 Boot mode rs E Yes Jumper Z Boot Mode CABLE CABLE a sea Sige IA Rea teers FEM FEM Normal Mode Figure 1 Connection scheme HD67223 A1 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 2000 Ethernet Document code MN67223_ ENG Revision 1 001 Page 5 of 17 Industrial Electronic Devices Jumperi Boot mode B Ye
14. s Jumper Boot Mode HO High wire ShlO Shield to Isolated Ground LO Low wire No Jumper g Normal Mode Port RS232 D SUB9 Male NMEA2000 Line i Mis Bj open PIN2 RX 0 006068606060909 PIN3 TX PIN5 GND B 120 ohm Used for A Programmation Port To connect the device to the COM port of a PC in order to set it you have to use the LO ShIO HO programming cable AC34107 S 8eeeeeeeOO O fear Green Link Ethernet Or a cable made as showed here Connector2 Ethernet Port RI45 Plug Power Supply CABLE CABLE Side A Side B FEM FEM No Boot Mode RUN OV Ground V Positive wire 12 VAC min 8v max 19v 4 VA 24 VDC min 8v max 35v 4 Watt Figure 2 Connection scheme for HD67223 B2 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 iV User Manual NMEA 2000 Ethernet Document code MN67223_ ENG Revision 1 001 Page 6 of 17 Industrial Electronic Devices CHARACTERISTICS The Configurable NMEA 2000 Slave to Ethernet gateway allow the following gt TCP UDP Ethernet protocols changeable with software gt Mountable on Rail DIN gt Temperature range 40 C to 85 C POWER SUPPLY Recommended Power Supply Caution Not reverse the polarity power VDC VAC Vmin Vmax Vmin Vmax Sv 35v Sv 19v HD67223 A1 HD67223 B2 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39
15. t folder with another name and open the new folder with the button Open Project gt When a new project is created or an existent project is open it will be possible to access the various configuration section of the Software ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL User Manual Document code MN67223 ENG Industrial Electronic Devices SET COMMUNICATION This section define the fundamental communication parameter of two buses NMEA 2000 and Ethernet By pressing the Set Communication button from the main window for SW67223 Fig 3 the window Set Communication appears Fig 4 The window is divided in two section one for the NMEA 2000 and the other for the Ethernet The means of the fields for NMEA 2000 are gt gt gt In the field Baud rate the baudrate for the NMEA 2000 is defined If the field CAN Bus 2 0A is checked the CAN with a CobID of 11Bit is used otherwise if the field CAN Bus 2 0B is checked the CAN with a CobID of 29Bit is used In the field TimeOut Data insert a time when this time is elapsed the data isn t reliable and in the Modbus register you can read FFFF If the field Peer to Peer is checked the gateway accept any ID that have the PGN inserted in the section Receive NMEA If the field Filter FECA is checked there is a filter to the alarms with PGN OxFECA If the device send
16. ytes that composed the respons are these Byte Number 1 Error n Number of Byte The Error Byte Byte 1 can have three values e 0x00 No error e 0x01 Starting Address doesn t exist e 0x02 Too many Data to read The TimeOut Byte Byte 2 can have three values e 0x00 TimeOut not used e 0x01 Data consistent e 0x02 Data not consistent Example We want to read ten frames from Starting Address 1 So the string of hexadecimal numbers is REQ 01 00 00 00 10 RES 00 01 01 02 03 04 05 06 07 08 09 OA OB OC OD OE OF 10 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices MECHANICAL DIMENSIONS 120 mm 4 72 inch cp G on p J G ES oa et Ex gt He N ri 33 a E Housing PVC 23 mm Weight 200g Approx 0 9 inch Figure 7 Mechanical dimensions scheme for HD67223 A1 ORDER CODE Order Code HD67223 A1 Order Code HD67223 B2 User Manual NMEA 2000 Ethernet Document code MN67223_ ENG Revision 1 001 Page 15 of 17 60 6000000390 95 mm 3 74 inch eeeeeeeeseo 71mm 60 mm 2 79 inch 2 36 inch Housing PVC Weight 200g Approx Figure 8 Mechanical dimensions scheme for HD67223 B2 NMEA 2000 Ethernet Converter NMEA 2000 Ethernet Converter ACCESSORIES Order Code AC34001 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail