Home
User`s Guide - Special Olympics
Contents
1. 5 2 hoe d a EE eeen 5 2 Internal Strip Printer Report seen eene nennen 5 2 Patient Report Form cete Eee e een eei 5 4 Estimating the Z score and Plotting Patient Results vs Age Dependent Reference V ales Di io eie inte enirn esI AD s 5 4 Sahara Caucasian Female Reference Database essere 5 6 Study OVervIeW shite eb peatones ep Peeters 5 6 Reference Data Ranges for the Sahara Clinical Bone 5 7 Modify Young Adult Estimated BMD Reference Values optional 5 9 Development and Use of Reference Data Ranges for Specific Patient Populations RNR TA 5 12 System Care and Maintemancee cccsccssssccssssccssssccssssssssscccsssccsssscessesssssesssssssssssescssssees L Ordering Supplies nee eer ette eet RE 6 1 Cleaning and Re Use site ER e Ups en tint 6 1 How Supplied ineo eno ette ueteri its 6 1 Infection Control ettet reser rre he ise e 6 2 Cleaning Frequency esset eem ne pp Oe ere Dp 6 3 How to Clean Disinfect the Sahara Unit esses enne 6 3 CHAM Bs cise sce 6 3 Disinfectng oie A eee Rhee eR Ae 6 3 Additional 6 3 Alternate Practices oie ere rette tese en Ui
2. 6 12 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 1 of 5 Gel pads 2 Press OPEN 9 For each transducer pad squeeze out about a one inch 2 5 cm bead of gel onto finger see the figure below Note Do not use a Q Tip examination glove containing talc or any other applicator that may introduce fibers or other foreign matter Figure 6 12 Measure Gel 10 Apply gel to the transducer pad Cover the entire surface area of the pad making sure that the leading edge of the pad is covered see the figure below Note Itis important that the leading edge of the transducer pad is fully covered Clinical User s Guide 6 13 6 System Care and Maintenance Figure 6 13 Apply Gel Figure 6 14 Leading Edge Gel Application Front View 11 When gel has been applied to both transducer pads press the OPEN PREP button The system opens the transducer pads to the fully open position 6 14 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 Figure 6 15 Press OPEN PREP Print Open Feed Prep A um pos Ca Jp os wo o cos sauand CLINKCAL BONE SOR VMIETER 12 Place the QC phantom in the Sahara Position the phantom so that its rounded end is snugly in the positioning contour heel cup and the flat side of the phantom is lying flat against the bottom of the system see the figure below Figure 6 16 QC Phantom in Position
3. 4 14 SAHARA Clinical Bone Sonometer Patient Measurement 4 Figure 4 22 Removing Positioning Aid 5 Remove the patient s foot from the scanner unit Provide the patient with tissues or towelettes to remove gel from their foot assist if necessary 6 Press OPEN PREP The scanner moves the transducer pads to the cleaning position Figure 4 23 Press OPEN PREP Print Open Feed Prep Eas 2s C4jCs jC e Program Coco SAHARA 7 Carefully clean and dry the transducer pads Use the towelettes supplied in the Accessories Kit to clean the transducer pads and dry wipes to dry them Clinical User s Guide 4 15 4 Patient Measurement Figure 4 24 Cleaning the Pads 8 The Control Panel Screen displays the Estimated BMD result and corresponding T score Est Heel BMD 0 340 T Score 2 2 If the Control Panel Screen displays Invalid Measurement Repeat or Out of Range Repeat message refer to the System Care and Maintenance chapter in this manual Note asterisk appearing after the Estimated BMD value indicates that the Estimated BMD was calculated using the SOS data alone The Estimated BMD is calculated from the SOS alone in those rare cases where the BUA data is considered unreliable due to the fact that the assumption of a linear attenuation vs frequency relationship was not fulfilled This condition is rare occurring almost entirely in a small percentage of younger
4. 20 Perform a QC measurement following the procedure in the chapter titled Quality Control in this manual Calibration Failure If the calibration procedure fails the Control Panel Screen displays the following message Calibration Failed Please Repeat If this occurs the calibration has not been changed Start the procedure over from the beginning Repeat all steps carefully If the calibration procedure fails again wait at least one hour for the phantom to stabilize at room temperature and repeat the procedure from the beginning Repeat all steps carefully If the calibration procedure fails a third time call your authorized Hologic service representative Clinical User s Guide 6 17 6 System Care and Maintenance Printer Operation Follow the procedure below to load printer paper 1 Remove the printer cover by sliding the cover towards the rear Figure 6 19 Removing Printer Cover 2 Grasp the paper roll in your hand and feed the paper through the printer as shown in Step 1 of Figure 6 20 and Figure 6 21 Insert the paper into the paper slot where arrows indicate The paper should feed from the underside of the roll Figure 6 20 Threading Printer Paper Step 1 Paper roll so FS c 6 18 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 3 To feed the paper press the PRINT FEED button while the display screen is displaying Gel
5. essere rennen 4 0 Figure 4 12 Heel Position eter he ES EE EESE 4 0 Figure 4 13 Positioning Aid Slightly Loose eese 4 10 Figure 4 14 Correct Leg Angle front to sse 4 10 Figure 4 15 Incorrect Leg Angle system too close eee 4 11 Figure 4 16 Incorrect Leg Angle system too far 4 11 Figure 4 17 Correct Leg Position side to side sse 4 12 Figure 4 18 Incorrect Leg Position side to side sseeeeee 4 12 Figure 4 19 Incorrect Position of Toes sess nennen 4 13 Figure 4 20 Positioning Aid Strap enne 4 13 Figure 4 2 Press MEASURE RII me or tette esi indere 4 14 Figure 4 22 Removing Positioning Aid sse 4 15 Figure 4 23 Press OPEN PREP a nee een eem eene tenere 4 15 Figure 4 24 Cleaning the Pads n cente pnto 4 16 Fis re4 25 Press PRINT a inerte tenir d tied eis 4 17 Figure 5 1 Press PRINT 5 3 Figure 5 2 Patient Report Form sese nren rennen enne 5 5 Figure 5 3 Press PROGRAM 7 ENTER eese nennen 5 10 Figure 6 1 Remove Transducer Pad Housing sese 6 5 Figure 6 2 Cleaning Transducer Face 6 6 Figure 6 3 Right Transducer Pad Alignment sessssseseseeeeneneee 6 7 Figure 6 4 Left Transducer Pad Alignmen
6. 13 Press the MEASURE button The system performs a measurement then automatically opens the transducer pads Clinical User s Guide 6 15 6 System Care and Maintenance Figure 6 17 Press MEASURE Print Open Feed Prep C jC2z Se Es Cs ul o ea sauand CLIMKCAL BONE SOR VMIETER 14 Remove the phantom 15 Press OPEN PREP The transducer pads return to the ready position Figure 6 18 Press OPEN PREP Print Open Feed Prep onan amp e C 9 C9 CLINKCAL BONE SOR VIETER 16 Carefully clean and dry the phantom and the transducer pads Use the towelettes supplied in the Accessories Kit to clean the phantom and transducer pads and dry wipes to dry them Note Itis important that the phantom and the transducer pads are thoroughly cleaned and dried after every pass of the calibration procedure 17 Press ON The Control Panel Screen displays the following message 6 16 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 2 of 5 Gel pads 2 Press OPEN 18 Repeat Steps 9 through 16 until all 5 passes of the calibration procedure are complete The Control Panel Screen displays the following message at the completion of the procedure Calibration Successful 19 Press ON This completes the calibration procedure The device will print out the complete calibration records Please save them for future reference
7. Note Never pull the paper either forwards or backwards through the printer Always advance the paper using the Print Feed button and tear off using the cover slit Figure 2 8 Printer Cover Replaced 2 8 SAHARA Clinical Bone Sonometer Initial Set Up 2 Set Time To set the time in your Sahara system follow the procedure below 1 Press ON The Control Panel Screen displays the following Gel Pads Press OPEN 2 Tosetthe time press PROGRAM 9 ENTER The Control Panel Screen displays the time in 24 hour format Figure 2 9 Press ai cene Print Open Feed Prep E Ea Program Caer CUD SAHARA Time XX XX 1 Change 2 Exit 3 If the time displayed is correct press 2 4 If the time displayed is incorrect set the correct time as follows 5 Press 1 The Control Panel Screen displays the following Clinical User s Guide 2 9 2 Initial Set Up Time 11 15 Hour 0 Insert the hour in 24 hour format then press ENTER The Control Panel Screen displays the following Time 11 15 Minute 0 Insert the minute then press ENTER The Control Panel Screen displays the following XX XX represents the time you set Time XOCXX 1 Change 2 Exit Press 2 to set the time as shown or press 1 to start over After the time has been set the Control Panel Screen displays Gel Pads Press OPEN 2 10
8. If at any time the patient feels discomfort during use of the Sahara unit the foot restraint mechanism is designed to allow the foot to be pulled out without having to operate any levers or handles The foot could also be removed by using the handles that fully release the foot restraint mechanism In addition the Open Prep button may be pushed at any time to open the transducer pads Note that in an emergency it is not necessary to open the pads before removing the patient s foot from the instrument Only Hologic approved ultrasound coupling gels should be used with Sahara Sahara Ultrasound Coupling Gel is for external use only For ultrasound coupling gel application do not use a Q Tip examination glove containing talc or any other applicator that may introduce fibers or other foreign matter When applying gel to the transducer pads it is important to ensure that the leading edge of the transducer pad is fully covered Interfacing equipment computer monitor printer used with the Sahara Clinical Bone Sonometer must meet IEC 950 or equivalent safety standards 6 Adverse Events There are no known potential adverse effects of the Sahara Clinical Bone Sonometer on health Safety Experience and Sample Size No adverse events of any kind were reported in the course of the clinical studies performed in which a total of 2455 subjects underwent Sahara examinations Deaths There were no patient deaths related to the Sahara Clinical
9. installed remove them clean all surfaces including transducer face with a no lint tissue and repeat the procedure from the beginning Figure 6 7 Pads Installed Correctly Incorrect Correct Calibrate System The Sahara system must be calibrated after removing replacing transducer pads Follow the procedure below System Calibration Each Sahara is supplied with a QC phantom which can also be used to calibrate the system System calibration is not usually necessary unless the transducer pads are removed or a malfunction has occurred requiring service To perform system calibration follow the procedure below Note Itis important that the system and phantom have equilibrated to room temperature for at least one hour before performing this procedure 6 Clinical User s Guide 6 9 6 System Care and Maintenance 1 Press the ON button The system initializes itself and closes the transducer pads until they touch and then opens them for gel application Figure 6 8 S Prep aae 8 Program IEEE ese SAHARA Figure 6 9 Transducer Pads Touch 6 10 SAHARA Clinical Bone Sonometer System Care and Maintenance Figure 6 10 Transducer Pads Ready for Gel Note If there is no operator action within ten minutes after ON is pressed the unit goes to Power Saver Mode the screen goes blank Press the ON key to return to the last screen 2 Press the PROGRAM button
10. sse 6 20 Figure 6 24 Press PROGRAM 6 ENTER eene eene nenne 6 21 Tables Table 1 Control Panel tette e oe nemen UR ten bore etie 1 20 Table 1 2 Sahara Specifications sess 1 21 Clinical User s Guide ix Table of Contents X SAHARA Clinical Bone Sonometer Introduction 1 Introduction and Background This chapter provides overview information about the Sahara Clinical Bone Sonometer with the Advanced Clinical Software Option the Sahara Advanced Clinical Bone Sonometer It includes a discussion of ultrasound measurement safety precautions system components and product specifications Essential Prescribing Information Caution Federal U S A Law restricts this device to sale by or on the order of a physician or properly licensed practitioner 1 Device Description The Sahara Clinical Bone Sonometer consists of the measurement unit its power cord power supply a foot positioning aide and accessories The Advanced Clinical Software Option consists of software for an external personal computer a communications cable and an Advanced Clinical User s Guide See How Supplied below for a complete list of accessories Ultrasound measurements are performed on the Sahara system with the patient seated and their foot positioned and secured in the Sahara system using a positioning aide After the patient s foot is secured a pair of soft elastomer pads are brought into contact w
11. Nonetheless threshold based guidelines and decision making are in fact commonplace in medical practice even in similar situations cholesterol testing for example but should be applied with the understanding that risk is continually increasing above and below the threshold The studies found that a similar relationship to hip fracture risk existed for heel ultrasound results with approximately a 2 fold increase in risk per population SD In particular one of the studies included both x ray based and ultrasound measurements of the heel and found essentially identical results the relative risk values for heel ultrasound and heel x ray BMD were 2 0 and 2 2 respectively For these studies heel ultrasound results were obtained using ultrasound systems that use a water bath to couple sound waves to the heel Sahara is a dry heel ultrasound system that uses soft elastomer pads and an ultrasound gel to couple sound to the heel but is otherwise similar to the wet systems used in the fracture risk studies Data comparing the Sahara and the Advanced Clinical User s Guide 1 15 1 Introduction Walker Sonix UBA 575 the system used in one of the fracture studies was obtained in the Sahara clinical study This comparative data demonstrates the strong linear relationship R 0 93 between Sahara and Walker Sonix results which in turn suggests that Sahara results are sensitive to risk of future fracture In order to estimate quantitatively the sen
12. Similarly if the patient s result falls midway between the lower most and next to lower most curve the Z score is 1 5 because it is 1 5 standard deviations below the age matched mean middle curve 5 4 SAHARA Clinical Bone Sonometer Comparison of Patient Results to a Reference Database 5 By this method the patient s Z score can be estimated graphically allowing their results to be interpreted both in comparison to age matched peers Z score as well as to Young Adult subjects T score Figure 5 2 Patient Report Form Q PATIENT REPORT FORM RE CLINICAL BONE SONOMETER Potent Nome JANE DOE bue AU 4 1447 mw 949 434 9469 EXAM sw n 0 w 19 1436 Aenea S S An o S3 wait 2 Oper ec TAN fores wm JONES RESULTS S HOLOGIC Date 8 04 1997 Time 11 28 Seria No 87 nae JANE Dok 000 2 w 7997 79 89 Etmicity NOTER LWA D O Est Heel 80 0 340 g on Remarks MD 32YO Flom T Soore 2 2 2 amp Estimated Hee BMD T Score Young Adult 20 0 1 T Score based on US Caucasian female reference data Reference data based on USA Caucasian Women HOLOGIC Clinical User s Guide 5 5 5 Comparison of Patient Results to a Reference Database Sahara Caucasian Female Reference Database Study Overview The
13. are described Reference values for specific populations can either be obtained from published scientific literature or alternatively may be developed by the physician When using reference values obtained from published scientific literature it is important to verify that the population studied is applicable to the patients that you will be evaluating and that the guidelines described below have been followed in the published study Guidelines for Development and Use of Young Adult Reference Values A minimum of 50 subjects between the ages of 20 and 30 years should be recruited randomly from the target population A single Sahara measurement should be performed on each subject If the Sahara result is marked by an asterisk indicating unreliable ultrasound results as described in Chapter 4 Patient Measurement the patient should be repositioned and the measurement should be repeated If the second measurement also is marked by an asterisk the patient s results should not be used for the development of the reference values and an additional subject should be recruited If the second measurement is not marked by an asterisk then it is acceptable to include the second result in the calculation of young adult reference values For each subject press the key on the keypad prior to pressing the PRINT FEED Key in order to get a hardcopy printout that includes all of the ultrasound parameters Results for the 50 subjects should be analyze
14. due to the phantom not being stabilized at room temperature Repeat the test in one hour If you suspect this is the problem it is acceptable to perform patient measurements before completing the QC procedures as patient results are not affected by incorrect phantom temperature However if this is not believed to be the problem or if the repeat message appears after waiting one hour refer to the Quality Control Problem section of the Chapter 6 System Care and Maintenance before performing patient measurements 15 If the QC results are well outside normal operating limits and outside of the range encountered when the temperature of the phantom is not stabilized the screen will display QC Failed Refer to Manual Repeat the QC procedure starting at Step 1 If the QC fails again refer to the Quality Control Problem section of the System Care and Maintenance chapter of this manual If the QC Failed message is displayed do not perform patient examinations 3 10 SAHARA Clinical Bone Sonometer Quality Control 3 until the QC procedure has been successfully completed or the system has been serviced Recording Plotting QC Results A PASSED QC result indicates that the Sahara system is functioning properly If desired QAB and QAS results may be recorded and plotted on the Sahara QC worksheets supplied with the unit These worksheets allow the daily QC results to be documented and the long term stability of BUA
15. 4 Press PROGRAM 1 ENTER enne nennen nene 3 4 Figure 3 5 Gel Measurement noe nee ect treten tr ned 3 5 Figure 3 6 Spread tato vr e io prre 3 5 Figure 3 7 Proper Amount of Gel on Transducer Pad ssssssee 3 6 Figure 3 8 Press OPEN PREP orea e taae e nennen trennen rennen enne 3 6 Figure 3 9 QC Phantom Position eeeeeeeeeeeeneeeeennnen nennen eene enne 3 7 Figure 3 10 Press MEASURE Bree ceto etse t b tee eode 3 8 Figure 3 11 Press OPEN PREP oen aice eaoin nennen nennen rennen enne 3 8 Figure 3 12 Press PRINT 3 03 ette nies ale ae eas ales 3 10 Figure 3 13 QC Log eque coenobii REED DURER 3 11 Figure 4 1 Comparison of Ultrasonic Coupling Gels sse 4 2 Fig re 4 2 Press ON iie oq irm be Eee patei be 4 3 Figure 4 3 Transducer Pads Touch sees 4 3 Figure 4 4 Transducer Pads Ready for Gel sse 4 4 Figure 4 5 Gel Measuremeht 2 De leise ise C pen pedet Die 4 5 Figure 4 6 Apply Gel eh ette e ltem etuer ent qe iuto oe 4 5 Figure 4 7 Gel Application seeeeeseeseeeeeeeen nennen nennen eene enne 4 6 Figure 4 8 Press OPEN PRED nhobeeee aeo tente Du E RR 4 7 Figure 4 9 Patient POSitOn 4 ns ette er en e b E pen 4 7 Figure 4 10 Patient Leg Position nennen eene eene eene 4 8 Figure 4 11 Patient Foot Position
16. Pads press OPEN Figure 6 21 Feed Printer Paper 4 Place the paper roll into the printer tray Insert the paper roll in the tray as shown in Figure 6 22 and Step 2 of Figure 6 20 Figure 6 22 Insert Paper Roll 5 Insert the paper through the slot in the printer cover and reinstall the cover Clinical User s Guide 6 19 6 System Care and Maintenance Note Never pull the paper either forwards or backwards through the printer Always advance the paper using the Print Feed button and tear off using the cover slit Figure 6 23 Printer Cover Replaced 6 20 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 Display Serial Number To display the unit s serial number from your Sahara system follow the procedure below 1 Press ON The Control Panel Screen displays the following Gel Pads Press OPEN 2 Press PROGRAM 6 ENTER The Control Panel Screen displays the serial number Figure 6 24 Press Print Open Feed Prep Ci jC2 JC 3 Program Co e cu SAHARA Serial Number XXXXXXX 3 After the serial number displays briefly the Control Panel Screen displays Gel Pads Press OPEN Clinical User s Guide 6 21 6 System Care and Maintenance What to do in Case of Trouble This section provides information to assist the user in case something goes wrong with the system Acquiring Results After a Paper Jam Clearing a Printer Pape
17. QC measurements must be obtained Typical SD values obtained with Sahara are 0 05 for QAB and 0 005 for QAS If results on your system are poorer than these values review the QC procedure above to insure that the measurements are being performed properly before contacting your service representative Clinical User s Guide 3 13 3 Quality Control 3 14 SAHARA Clinical Bone Sonometer Patient Measurement 4 Patient Measurement This chapter describes how to perform a patient measurement on the Sahara Clinical Bone Sonometer Warning If the patient s skin in the area to be tested and or the area that comes into contact with the Sahara system transducer pads or foot positioning aid i e heel foot ankle shin or calf is abraded and or has an open sore do not measure that heel If skin is abraded and or has an open sore on both heels legs the patient should not be assessed with the Sahara system Note about Ultrasound Coupling Gels The selection and proper application of coupling gel are critical in obtaining correct ultrasound test results Water based gels used so effectively for qualitative imaging ultrasound modalities cause a significant delay in pad to skin coupling which can have a significant effect on quantitative ultrasound results Because Sahara ultrasound measurements are obtained so quickly the time dependence of quantitative ultrasound results Figure 4 1 obtained using water based coupling gels
18. QC phantom results should not be confused with expected results in vivo However it is important to perform QC in order to verify that the system is performing properly and that the results are in the acceptable range 3 12 SAHARA Clinical Bone Sonometer Quality Control 3 Over long periods of time several months or more it is typical for the results of the two QC parameters to have mean or average values ranging between 0 93 and 1 07 for QAB and between 0 993 and 1 007 for QAS That is the mean values for QAB and QAS fall approximately within the middle portion of the acceptable range for each parameter Note that QC results for a given day or for a few days can fall outside of the middle of the acceptable range However if the QC results are consistently for more than two weeks falling near to the edge of the acceptable limits the System should be re calibrated as described in the System Care and Maintenance Chapter of the User s Guide It is important to understand that as long as the QC results fall within the acceptable range as indicated by the QC Passed message it is acceptable to perform patient examinations as the system is performing within specifications The typical daily fluctuations observed over long periods of time several months or more can be described in terms of the standard deviation SD of the QAB or QAS results Note that in order to obtain a reliable estimate of the SD at least 2 weeks 10 or more
19. The Control Panel shown in Figure 1 7 contains a display screen numeric keypad and five functional switches Print Open Feed Prep eae a C82 ae 9 383 e ERIS as CLINKCAL GONE S01 MIETER Advanced Clinical User s Guide 1 19 1 Introduction Table 1 1 describes the functions on the Sahara Control Panel Table 1 1 Control Control Panel Numeric Keypad LCD Screen ON Button OPEN PREP Button MEASURE Button PRINT FEED Button Program Button ENTER Button Button 1 20 SAHARA Clinical Bone Sonometer Description The Numeric Keypad consists of the numbers 0 through 9 the Program and Enter buttons These are used to enter phantom information and other numeric data The Numeric Keypad is not normally used during patient measurements The LCD display screen displays messages to prompt the user through a measurement and displays the result of a measurement This button takes the system out of standby mode or initializes the system to prepare for a new measurement This button places the transducer pads in the Open fully open or Prepare half open positions and may be used to open the pads anytime they are closed or are closing This button commands the system to close the transducer pads and perform an ultrasound measurement This button commands the system to print the current results or advance printer paper if the optional line printer is supplied This b
20. and SOS QC results to be visually monitored Log the displayed results on the Quality Control Log sheets provided Each log sheet can accommodate one month of QC results and in order to simplify the graphical plots only the QAB and QAS values are recorded Note that it is simple to convert the QAB and QAS values to BUA and SOS values by multiplying the QAB value by the phantom BUA value on the phantom label and by multiplying the QAS value by the phantom SOS value on the phantom label Figure 3 13 QC Log QUALITY CONTROL LOG Month fotos Year 2 Clinic _OSTBoPom sTs CLINIC Operator XxX 1 System SIN 77 Phantom S N 27 Phantom BUA 29 E w Phantom SOS S2 4 Day QAB Rel Units QAS Rel Units _ quee QAB 13 15 17 19 21 23 25 27 29 31 Day of month QAS Rel Units Pus E QAS 1 08 1 1 024 1 01 1 00 9902 9804 970 canard CLINICAL BONE SONOMETER PIN 080 0606 Rev A At the beginning of each month a new QC Log sheet should be started by filling in the Month Year Institution Name System Serial Number Phantom Serial Number Phantom Clinical User s Guide 3 11 3 Quality Control BUA Phantom SOS and operator name Note that Phantom Serial Number BUA and SOS values are given on the label attached to the phantom Each day after the QC measurement is p
21. eese nennen nenne 1 10 Figure 1 2 Sahara Measurement Geometry sese 1 11 Figure 1 3 SOS Measurement cece eeeeceeeeceescesecesecesecaecsaecseecneeeseseeeeeeesereeeensees 1 12 Figure 1 4 BUA Measurement 000 000 cece eeceeceeecesecesecesecaecsaecaeecnaseaeseaeeeeeeeseeeesees 1 13 Figure 1 5 System Components sess enne eene nennen 1 18 Figure 1 6 Power Status Light essere nennen nenne 1 19 Figuie1 7 Control Panel eio ted tee tusten Ul e Rete 1 19 Figure 2 1 Unpacking the System sess enne 2 2 Figure 2 2 Power Supply Connections 2 3 Figure 2 3 Power Status Laght aet oet eet epi tee 2 4 Figure 2 4 Removing Printer Cover essent netten 2 6 Figure 2 5 Threading Printer Paper sess 2 6 Figure 2 6 Feed Printer Paper eee 2 7 Figure 2 7 Insert Paper Roll rir rrt rr PRO 2 7 Figure 2 8 Printer Cover Replaced ane doe eene dee DI geret 2 8 Figure 2 9 Press Program 9 ENTER een rennen 2 9 Figure 2 10 Press PROGRAM 8 ENTER eere eene nenne 2 11 Figure 3 I Press ON edepol UR DURO ERR Re Eee 3 2 Figure 3 2 Transducer Pads Touch essere 3 3 Clinical User s Guide vii Table of Contents Figure 3 3 Transducer Pads Ready for Gel sese 3 3 Figure 3
22. from the floor The Sahara operator should be seated on a low height stool such as an exam stool Unpacking the System Figure 2 1 shows the key components of the Sahara Clinical Bone Sonometer Refer to the figure and the list below it to insure that all items were received Clinical User s Guide 2 1 2 Initial Set Up Figure 2 1 Unpacking the System Sahara Instrument Positioning Aid Sahara Ultrasound Coupling Gel ad QC Phantom lt Power Supply Power Cord The Sahara shipping package includes the following Sahara system Power Supply and Power Cord Positioning Aid QC Phantom Training Video Sahara User Video Guide Starter supplies including Sahara Ultrasound Coupling Gel 2 tubes Transducer Towelettes 1 pkg Dry wipes 1pkg Pinter paper 2 rolls Ultrasound exam paper 1pkg e Documents package containing User s Guide Supplies reorder cards Installation Warranty and Post Warranty Service Information Sheet QC Log Forms 1 tablet Patient Report Forms 1 tablet Patient Information Brochures 1 pkg Sahara Physician Learning Series To unpack the system follow the procedure below 2 2 SAHARA Clinical Bone Sonometer Initial Set Up 2 1 Remove the top tray containing the Power Supply QC Phantom Training Video starter supplies and documents package 2 Remove the foam packaging material that covers the top of the system 3 Remove positioning aid wrapped in packagin
23. males and females with high bone density On occasion this condition may also be caused by improper foot positioning or not enough coupling gel Therefore if the measurement has an asterisk it is recommended that the operator repeat the measurement If the second measurement does not have an asterisk it should be used and the first measurement ignored If the second measurement also has an asterisk these results should be interpreted with caution especially if used for patient monitoring 9 Press the Print Feed button on the Control Panel to obtain a hard copy record if desired Fill in the patient information immediately before the patient leaves in order to avoid confusion later A sample printout is shown see Internal Strip Printer Report and Fig 4 25 below 4 16 SAHARA Clinical Bone Sonometer Patient Measurement 4 If desired press the button to display the results for the ultrasound parameters QUI BUA and SOS before conversion to Estimated Heel BMD units pressing the button again toggles back to the Estimated BMD result Note that the printed report will include the QUI BUA and SOS results as well as the Est BMD results if the Print Feed button is pressed when the ultrasound parameters are displayed on the LCD screen 10 To see the most recent measurement results after the LCD screen has gone blank press ON to initialize the system and then press the button to display the results of the last exa
24. printer uses thermal paper that is coated on one side only To correct this problem carefully remove the roll of paper and reinstall correctly Power Problem If the screen does not display Version Number when power is applied check the following Is the power supply plugged into the system Is the power cord plugged into the power supply Is the power cord plugged into the wall outlet Are you certain there is power at the wall outlet If not try another outlet e Is the power status light small green light near the system power connector on If all of the above conditions are OK and the power status light is off there may be a problem with the power supply Try unplugging the system from the wall outlet waiting a few seconds and plugging it in again This causes the system to automatically run an internal diagnostic test which may clear the problem If this does not clear the problem contact your authorized Hologic service representative System Malfunction and Error Log There are extensive diagnostics embedded in the Sahara system to monitor the operating performance of the software electronics and mechanical aspects of the product When a malfunction occurs the type of malfunction is automatically stored in an internal log and one of the following messages is displayed Power On Self Test Failed followed by Error Code a Cat b HiCat c Or Clinical User s Guide 6
25. subjects spanned the entire clinical range of heel BMD with an approximately uniform distribution in order to document the agreement between Sahara and DXA across the entire useful range Hip BMD results were used to classify elderly subjects using the internationally accepted World Health Organization WHO criteria Results for 2208 subjects age range 19 97 were obtained for development of reference ranges Caucasian female subjects were chosen for these studies as they are the group most frequently affected by osteoporosis e Methods Heel BMD was estimated by Sahara for all subjects including 5 replicate measurements for the 247 subjects in the comparative study The 247 subjects from the comparative study also underwent BMD assessment by DXA Walker Sonix heel ultrasound results were obtained for 212 of the 247 subjects in the comparative study e Principal Effectiveness and Safety Results Comparison of BMD Sahara Est Heel BMD was linearly related to Heel BMD Results vs Heel DXA R 0 85 Comparison Sahara Est Heel BMD essentially identical to Heel DXA or Sensitivity to DXA comparisons of clinically distinct subject groups Similar in sensitivity to spine DXA Reproducibility of Est Heel BMD reproducibility was found to be 3 0 in the 247 Heel BMD subjects studied Sahara female subjects and are included with standard Sahara system Comparison of Sahara QUI and Est Heel BMD results were linearly related to Res
26. the broad band ultrasound attenuation BUA and is measured in dB MHz On the Sahara system the BUA and SOS are measured at the same time As is the case for the SOS measurement in order to determine the attenuation of the heel alone and remove any effects arising from the transducers and or transducer pads a comparison measurement must be made through a reference medium This reference measurement is made using the Sahara QC Phantom supplied with the Sahara unit when the unit is calibrated at the factory The range of BUA observed with Sahara in a typical population is approximately 30 130 dB MHz with young healthy subjects having higher BUA results than older or osteoporotic subjects Note In the course of typical usage it is not necessary to perform a reference measurement calibration However if the transducer pads transducers or electronics are removed or disassembled for any reason the unit must be re calibrated following the instructions in the Maintenance chapter of this manual 1 12 SAHARA Clinical Bone Sonometer Figure 1 4 BUA Measurement Introduction 1 HEALTHY BONE OSTEOPOROTIC BONE 100 dB Mhz 50 dB Mhz Attenuation Attenuation Frequency Frequency Estimated Heel BMD and the Quantitative Ultrasound Index QUI In order to optimize the quantitative information obtained by both BUA and SOS measurements the Sahara system combines linearly the two measured values into a single param
27. these ranges and repeating the QC procedure after 1 hour will give acceptable results due to the stabilization of the phantom temperature In addition Sahara also automatically identifies QC results that are far enough outside of the acceptable range as to indicate either a procedural error no gel used for example or a system malfunction In such a case the system displays a Failed message and the system should not be used to evaluate patients until an acceptable result is obtained or the unit is serviced The remainder of this chapter describes the procedure for performing QC measurements and guidelines for interpreting results QC measurement consists of initializing the system applying gel to the pads opening the pads positioning and securing the QC Clinical User s Guide 3 1 3 Quality Control phantom in the system performing the measurement printing the measurement results removing the phantom from the system and cleaning the phantom and the pads QC results may be plotted as a function of time using the Quality Control Log sheets described in the section titled Recording Plotting QC Results in this chapter The QC Log sheets will allow recording and plotting of QC results with one month of QC data recorded on each sheet Quality Control Procedure To perform QC follow the procedure below 1 Press the ON button The system initializes itself and closes the transducer pads until they touch and then opens them f
28. will result in unacceptably variable results Of course the variability shown in Figure 4 1 while typical of the general population may vary on an individual basis Certain oil based gels also exhibit this time dependence and it is therefore critical that ONLY Hologic approved ultrasound coupling gels be used with Sahara Two tubes of Sahara Ultrasound Coupling Gel are supplied with each Sahara unit Additional tubes can be reordered from Hologic Use the reorder form included in the Sahara starter kit or contact your Hologic representative Clinical User s Guide 4 1 4 Patient Measurement Figure 4 1 TN Comparison of Ultrasonic Gels Coupling Gels Sahara a Oil based gel Water based o b o x 2 m o 50 100 150 200 Time seconds In order to obtain highly reproducible results avoid these common causes of measurement imprecision Poor Patient Seating The patient should be seated in a straight chair without rollers Poor Foot Preparation The foot should be dry and clean when making a measurement Improper Foot Placement Use the exam paper for each measurement as it allows the foot to slide easily against the rear of the footwell Make sure the positioning line is between the second and third toe Misuse or Lack of Use of Foot Positioner Always use the foot positioner Make sure that when it is applied the patient is comfortable 4 2 SAHARA Clinical Bone Sono
29. 2 T scores for an individual patient This means that individual patients may be classified differently by Sahara compared to DXA when using the World Health Organization WHO classification criteria The WHO criteria classify patients with BMD values more than 2 5 SD s below the young adult mean T score below 2 5 as osteoporotic and patients with T scores between 1 and 2 5 as osteopenic However the differences in T score results obtained by Sahara and heel DXA are similar to or smaller than the differences found when patients are assessed by any other two accepted methods for assessing BMD of the same anatomical site For example the 95 confidence interval is 1 8 T scores for DXA vs of the spine Furthermore the differences for an individual patient assessed at two different anatomical sites can be even larger due to physiological and anatomical differences between the various sites It is widely accepted that while any measure of BMD is a strong indicator of risk for osteoporosis and osteoporotic fractures classification by the WHO criteria is dependent on the measurement technique and even more so on the measurement site Thus an understanding of the potential differences in T score results obtained by different techniques should be considered when applying the WHO classification criteria When using threshold based criteria to classify patients the continuous exponential increase in fracture risk with decreasing BMD see R
30. 23 6 System Care and Maintenance ault Mid a Pid b Vid c FC d e followed by XXXXXXXXXXXXXX yyyyyyyyyyyyyy If this message is seen International customers should contact their authorized Hologic service representative US customers should contact Hologic Customer Service at 800 321 4659 The service department will ask you to print out an exception report Make sure the unit is powered on and follow the procedure below to print an exception report Printing the Exception Report 1 OO CH VON Press ON and wait for the pads to move apart Press PROGRAM Press 4 Press 2 Press ENTER Press 9 Press 3 Press ENTER The printer will print an exception report see example below 6 24 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 Exception Report Date 8 22 96 Serial Number 123456 FAULT Mid 40 Pid 4 Vid 1 FC 7 FV 42 Invalid Msg DataTask ERROR Code 0 Cat 24 HiCat 24 End of Exception Report FAX this to your authorized Hologic service representative Quality Control Problem At the completion of the Quality Control procedure using the QC phantom the Control Panel Screen should display the word Passed If the system fails this procedure the Control Panel Screen will display QC Failed Refer to Manual If after trying the procedure twice the system does not pass check the following 1 Is the sm
31. 6 Set Time pn eto eer PP Rte pe ee eret es 2 9 E 2 11 Set Lan Guage etri ete artes tet c 2 13 Quality niece et eter re POPE Quality Control Procedure eee cece enne 3 2 Recording Plotting QC Results eese ener nenne 3 11 Interpretation Of QC Results zio opi tee p ee hee tede 3 12 Clinical User s Guide Table of Contents Patient Measurement oeeeesteceesestocve ne cite vaxcecceceasacdssceouscetesdseshoavcececscastedeosecevestese Note about Ultrasound Coupling 4 1 Sahara Patient Measurement enne enn 4 3 Prepare Lransducer Pads noster pense ote ge nee 4 3 Position eoe eei det iode egre ee beg 4 7 Meastire P atientz eso ect RE ERE ERE REESE PLE ONERE E EES 4 14 Internal Strip Printer eene 4 17 Patient Report ot e e EP yes REID RD UE echt 4 18 Precision of Sahara Results eite eee ie ere ree e e Ee tees 4 18 Considerations for Patient Monitoring essere 4 19 Comparison of Patient Results to Reference Values eeeeeeee eere ee 9 1 Types of Reference Database Comparisons seessseseseeeeneeneneeeeeeen 5 1 Reference Database Comparisons Available with
32. 60 watts automatically adjusts from 100 VAC to 240 VAC and 50 Hz to 60Hz CPU Embedded microprocessor Ultrasonic Energy Isppa lt 0 001 W cm typical lt 0 001 mW cm typical Mechanical Index MI 0 01 typical Pulse Repetition Rate PRR 200 Hz Safety Standards IEC601 1 UL2601 1 CSA C22 2 Size 17 D x 14 W x 12 H 43cm x 36cm x 30cm Weight 22 Ib 10 kg Advanced Clinical User s Guide 1 21 1 Introduction 1 22 SAHARA Clinical Bone Sonometer Initial Set Up 2 Initial Set Up This chapter describes how to set up the Sahara Clinical Bone Sonometer It covers examination room requirements unpacking system set up and printer operation Examination Room Environment Hologic recommends a clean dry examination room with the temperature of the room maintained between 65 and 75 F 20 and 27 C If possible store the Sahara in the same room used for patient measurement to minimize temperature changes to the instrument Do not store the unit near a heat source or air conditioner Store the phantom near the unit Note Never store the QC phantom in the footwell with the transducer pads closed on it This will ruin both the phantom and the transducer pads The exam room should have a standard electrical outlet and a stationary not rocking or gliding straight back chair for the patient The patient chair should have arms for patient comfort and a seat height of approximately 16 to 18 inches 41 to 46 cm
33. Bone Sonometer either during or after the clinical studies Adverse Events There were no adverse events related to the Sahara Clinical Bone Sonometer either during or after the clinical studies Adverse Events that may be expected There are no known potential adverse effects of the Sahara Clinical Bone Sonometer on health Therefore adverse events are not expected in conjunction with the use of Sahara Advanced Clinical User s Guide 1 3 1 Introduction 7 Clinical Studies e Purpose of Studies The clinical studies were designed to 1 directly compare estimated heel BMD results obtained on Sahara to those obtained on the established Dual Energy X ray Absorptiometry DXA technique 2 assess the sensitivity of Sahara heel BMD results to skeletal status vs that of DXA by comparing results obtained for clinically distinct groups of young and elderly subjects 3 assess the reproducibility of Sahara heel BMD results 4 document the safety of the Sahara system 5 obtain age dependent reference ranges for Sahara estimated heel BMD results for a Caucasian female population and 6 directly compare Sahara results to those obtained by the Walker Sonix UBA 575 heel ultrasound system establishing the relationship between Sahara and fracture risk estimation e Patients Studied Results for 247 Caucasian female subjects were obtained for the direct comparison of Sahara and DXA heel BMD results Recruitment criteria were set to insure that these
34. CLINICAL BONE SONOMETER User s Guide atm Document No 080 0631 Revision D HOLOGIC January 1998 The information contained in this Manual is confidential and proprietary to Hologic Inc This information is provided only to authorized representatives of Hologic s customers solely for the purpose of facilitating the use of Hologic s products No information contained herein may be disclosed to any unauthorized person for any purpose whatsoever without the prior written consent of Hologic Inc OCopyright 1997 and 1998 by Hologic Inc All rights reserved The Hologic logo and the Sahara logo are registered trademarks of Hologic Inc Printed in the U S A trademarks registered trademarks and product names used within this document are the property of their respective owners Hologic Inc 590 Lincoln St Waltham MA 02154 USA Tel 781 890 2300 Fax 781 890 9661 Service 800 321 HOLX 321 4659 User Support 800 321 HOLX 321 4659 Hologic Europe N V Avenue H Matisse Laan 14 Bruxelles 1140 Brussel Belguim Tel 32 2 705 30 20 Fax 32 2 705 15 11 SAHARA Clinical Bone Sonometer WARRANTY SOFTWARE LICENSE amp LIMITATION OF LIABILITY Sahara The following terms are an essential part of your agreement with Hologic By using any Hologic equipment covered in this manual you agree to be bound by these terms If you do not agree to these terms you must contact your Hologic representat
35. Cleaning Remove all coupling gel first from transducer pads after each patient or phantom measurement by wiping the surface with the towelettes or dry wipes supplied with the Sahara unit Spray Cavicide disinfectant cleaner on transducer pads foot well positioning aide and other scanner surfaces as necessary Wipe clean using the towelette or dry wipes Discard the used towelette or dry wipe Disinfecting Remove all coupling gel first from transducer pads after each patient or phantom measurement by wiping the surface with the towelettes or dry wipes supplied with the Sahara unit Spray Cavicide disinfectant cleaner on transducer pads foot well positioning aide and other scanner surfaces as necessary Allow to remain wet for 3 minutes at room temperature Follow by wiping clean with the towelette or dry wipe Discard the used towelette or dry wipe Additional Measures As an additional precautionary measure exam paper should be placed under the patient s foot on the Sahara unit during use to provide a physical barrier against possible soiling or contamination Exam paper should be discarded after every single patient measurement Alternate Practices If another disinfectant cleaner provides the same level of protection as Cavicide the customer at their own discretion may clean the Sahara unit s surfaces with an alternate product Always clean any gel thoroughly off the exterior of the scanner with a towelette Pay careful attenti
36. SAHARA Clinical Bone Sonometer Initial Set Up 2 Set Date To set the date in your Sahara system follow the procedure below 1 Press ON The Control Panel Screen displays the following Gel Pads Press OPEN 2 Tosetthe date press PROGRAM 8 ENTER The Control Panel Screen displays the date Figure 2 10 Press Print Open Feed Prep Ci C 2 J 3 Program Gaj Jes CUD SAHARA Date 2 17 1997 1 Change 2 Exit 3 If the date displayed is correct press 2 4 Ifthe date displayed is incorrect set the correct date as follows 5 Press 1 The Control Panel Screen displays the following Date 2 17 1997 Month 0 Clinical User s Guide 2 11 2 Initial Set Up 6 Insert the month then press ENTER The Control Panel Screen displays the following Date 2 17 1997 Day 0 7 Insertthe day then press ENTER The Control Panel Screen displays the following Date 2 17 1997 Year 0 8 Insert the year for example 1997 then press ENTER The Control Panel Screen displays the following XX XX XXXX represents the date you set Date 2 17 1997 1 Change 2 Exit 9 Press 2 to set the date as shown or press 1 to start over 10 After the date has been set the Control Panel Screen displays Gel Pads Press OPEN Note Time and date may be set whenever the Gel Pads Press OPEN or Gel Pads for QC Press OPEN screens are
37. Sahara Reference Data and Normative Ranges Study was designed to the acquire data from which age dependent reference values for Caucasian American females could be derived These reference ranges are based on Sahara results for 2208 Caucasian female subjects from ages 19 to 97 who were recruited at 9 clinical sites located across the United States The large number of clinical sites and subjects enrolled allows for maximum confidence in the reference ranges obtained and also reduces the possibility of regional bias This reference data study is unique in that the number of subjects and clinical sites are significantly larger that that of typical manufacturer sponsored reference data studies for bone densitometry equipment Sahara results were obtained for each subject enrolled in the study as was information regarding medical conditions and therapeutic regimens that may have an effect on bone mineral metabolism This information allowed the effects of including or excluding these subjects to be evaluated statistically The study was unique in that even after excluding all subjects with these conditions or treatments the number of subjects is still larger than that of most typical bone densitometry reference data sets Clinical Sites for the Sahara Reference Data Study State City Site Name Subjects 6 TN Memphis Univ ofTennesee 211 7 UT i Salt Lake City Univ ofUtah 98 8 VT _ Buringon Univ of Vermont 383 9 T
38. TEN AGREEMENT SIGNED BY HOLOGIC BUYER AGREES THAT THEIR AGREEMENT SHALL BE GOVERNED BY MASSACHUSETTS LAW AND THIS WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SAHARA Clinical Bone Sonometer SOFTWARE LICENSE All Software is supplied under this license only Hologic retains all title to and all copyrights to Software and any copies thereof Buyer is granted a non exclusive royalty free license to use Software solely on the equipment on which it is installed at time of Delivery or on the equipment for which it is intended to be installed if it is not yet installed when Delivered for as long as Buyer shall own such equipment Software may be used for performing measurements on this equipment in the normal course of Buyer s business but for no other purpose or business No license is provided to use Software for multi site quality control or data review purposes Buyer must maintain all copyright proprietary and other notices on Software and must not decompile disassemble or reverse engineer the Software and must not make it available to any party except those using the Software as part of their duties If the Buyer transfers Software or equipment on which Software is installed to a third party the Buyer may assign these rights to use Software on the same equipment to this third party p
39. WA Seattle Pacific Medical Ctr 394 5 6 SAHARA Clinical Bone Sonometer Comparison of Patient Results to a Reference Database 5 Reference Data Ranges for the Sahara Clinical Bone Sonometer The Sahara study data was analyzed by computing the mean values standard deviations and percentiles on a decade by decade basis Statistical testing demonstrated that the population standard deviation was age independent and that the percentiles described a normal distribution within statistical limits Statistical testing indicated that the effect of excluding subjects with conditions medications which may effect bone metabolism was negligibly small Thus the final reference ranges were based on all 2208 enrolled subjects and consist of the decade specific mean values and the mean from all the subjects pooled population Standard Deviation The resultant reference ranges implemented into the Sahara system are tabulated where the mean and population standard deviation are given for each decade Note that for ages between those in the table reference mean values are obtained by linearly interpolating between the values in the table The population standard deviation is constant and is not interpolated Age dependent reference ranges were similarly analyzed and developed for the raw ultrasound parameters reported by the Sahara system including Broadband Ultrasonic Attenuation BUA Speed of Sound SOS and Quantitative Ultrasound Index QUI S f
40. ach decade of age should be recruited randomly from the target population A single Sahara measurement should be performed on each subject If the Sahara result is marked by an asterisk indicating unreliable ultrasound results as described in Chapter 4 Patient Measurement the patient should be repositioned and the measurement should be repeated If the second measurement also is marked by an asterisk the patient s results should not be used for the development of the reference values and an additional subject should be recruited If the second measurement is not marked by an asterisk then it is acceptable to include the second result in the calculation of young adult reference values For each subject press the key on the keypad prior to pressing the PRINT FEED key in order to get a hardcopy printout that includes all of the ultrasound parameters Results for the subjects in each decade of age should be analyzed independently to determine the mean or average value and the population standard deviation SD value for each Sahara output parameter Est BMD QUI BUA and SOS The mean value and standard deviation can be computed using most hand held scientific calculators and does not require sophisticated computer software Check that for the 20 30 year age group the SD value for the Est BMD is in the range of 0 070 to 0 150 g cm If the SD is not in this range it is possible that an error was made in the calculation of the SD Che
41. ahara system follow the procedure below 1 Press ON The Control Panel Screen displays the following Gel Pads Press OPEN 2 Press PROGRAM 7 ENTER Clinical User s Guide 5 9 5 Comparison of Patient Results to a Reference Database Print Open Feed Prep Figure 5 3 Press PROGRAM 7 ENTER INCI jes ee SAHARA The Control Panel Screen displays the previously set young adult BMD reference mean Note that 0 581 is the US Caucasian female reference value and 0 112 is the US Caucasian female population standard deviation YAdit BMD Mean 0 581 1 Change 2 Exit If you do not wish to change the young adult reference mean press 2 If you want to set anew young adult reference mean set the correct mean as follows Press 1 The Control Panel Screen displays the following YAdlt BMD Mean 0 581 New Value 0 Insert the young adult BMD reference mean then press ENTER 0 581 is the US Caucasian female reference value and entering 0 0 disables the T score calculation The Control Panel Screen then displays the previously set young adult population standard deviation YAdit BMD SD 0 112 1 Change 2 Exit If you do not wish to change the young adult BMD reference standard deviation press 2 5 10 SAHARA Clinical Bone Sonometer Comparison of Patient Results to a Reference Database 5 9 If you want to set a n
42. all green light near the scanner power connector on If all of the above conditions are OK and the green power indicator light is off there may be a problem with the power supply 2 Try unplugging the system from the wall outlet and plugging it in again This causes the system to automatically run an internal diagnostic test which may indicate or clear the problem 3 Is the system including the phantom acclimated to room temperature Temperature is the most likely cause of this problem If you are not sure if the system including the phantom is acclimated to room temperature wait at least one hour with the system on then try again 4 If the transducer pads have been removed or replaced has the procedure been followed carefully including calibration Check the procedure titled Removal Replacement of Transducer Pads in this manual and repeat it if necessary Ensure that the pad couplant is spread evenly about a 1 16 inch coating on the flat Clinical User s Guide 6 25 6 System Care and Maintenance side of the pad Ensure that the transducer housings are screwed in securely so that the guide marks line up 5 Ifthe above does not fix the problem International customers should contact their authorized Hologic service representative US customers should contact Hologic Customer Service at 800 321 4659 Patient Measurement Problems Asterisk after Estimated BMD result Est BMD 0 500 g cm An asterisk appe
43. ance 6 repeat the measurement If after three attempts to measure a patient the display still indicates REPEAT contact your authorized Hologic service representative Measurement Out of Range This error indicates that the calculated SOS and or BUA is outside the unit s measurement range Some possible causes of this error are inadequate gel on pad tips something between pads and foot stockings on Repeat the measurement If after three attempts to measure a patient the display still indicates REPEAT contact your authorized Hologic service representative Clinical User s Guide 6 27 6 System Care and Maintenance 6 28 SAHARA Clinical Bone Sonometer
44. ap The patient should be comfortable and must remain still during the measurement Clinical User s Guide 4 13 4 Patient Measurement Safety Note The positioning aid incorporates a safety release mechanism In the event Measure Patient 1 Figure 4 21 Press MEASURE that it is necessary for the patient to remove their foot from the scanner unit at any time during the scan arching the foot by pressing the toes down and lifting the heel up will release the positioning aid Detach the positioning aid strap to remove positioning aid from the leg Before taking the measurement double check the patient s heel to ensure that it is in the center of the heel cup If the patient s heel is not centered remove the positioning aid and start over at Step 9 Press the MEASURE button on the Control Panel The system closes the transducer pads to the measurement position and performs the SOS and BUA measurements The measurement takes less than ten seconds Print Open Feed Prep C2 jC rogram Ca 5 C s ES Cs o Um 253 sanar CLINICAL BONE SOK METER Upon completion of the measurement the system sounds an audio tone beep and opens the transducer pads to the fully open position The Control Panel Screen displays 1 Remove Foot 2 Press PREP 3 Clean Remove the positioning aid strap and positioning aid The positioning aid is released by pressing the release latches and lifting the guide see the figure below
45. ara Clinical Bone Sonometer Each Sahara is supplied with a Quality Control phantom to monitor system performance over time It is recommended that a QC phantom measurement be performed each day prior to using the system to measure patients However it is acceptable for the QC measurement to be performed after patients are measured if the system and phantom are not at the same temperature as described in the note below Note Always store the QC phantom near the Sahara system BUA and SOS readings for the phantom are temperature dependent and may vary if the phantom and system are not maintained at the same room temperature Thus it is important that the phantom be kept near the system so that they are at the same temperature If the phantom has not been kept in the same location allow one hour for the temperature of the phantom to stabilize before using the phantom for calibration or QC Never store the phantom in the unit footwell with the pads closed on it as this will destroy both the pads and the phantom Because the variation of the ultrasonic properties of the phantom due to temperature are larger than the Sahara unit s short and long term precision QC results provide a conservative estimate of the performance of the Sahara system It is common to observe fluctuations in QC results within the normal acceptable range defined by the dashed lines on the Quality Control Log forms see below Occasionally QC results will be outside of
46. aring after the Estimated BMD value indicates that the Estimated BMD was calculated using the SOS data alone The Estimated BMD is calculated from the SOS alone in those rare cases where the BUA data is considered unreliable due to the fact that the assumption of a linear attenuation vs frequency relationship was not fulfilled This condition is rare occurring almost entirely in a small percentage of younger males and females with high bone density On occasion this condition may also be caused by improper foot positioning or not enough coupling gel Therefore if the measurement has an asterisk it is recommended that the operator repeat the measurement If the second measurement does not have an asterisk it should be used and the first measurement deleted from the database If the second measurement also has an asterisk these results should be interpreted with caution especially when used for patient monitoring Invalid Measurement Repeat This error indicates that the unit could not make a proper measurement Some possible causes of this error are foot moved during measurement inadequate gel on pad tips foot between the pads measured heel width outside of specified foot size range If the patient s foot size is outside of the specified foot range see Specifications in Chapter 1 of this User s Guide the patient cannot be assessed with Sahara Otherwise 6 26 SAHARA Clinical Bone Sonometer System Care and Mainten
47. ck that for the 20 30 year group the mean value for the Est BMD is in the range of 0 400 to 0 700 g cm If the mean value is not in this range it is possible that an error was made in the calculation of the mean Note that any values may be entered into the Sahara system for the mean and SD and there may be populations for which values outside of these ranges are valid but most populations should have values that fall in these ranges Z scores may be obtained either graphically by generating a reference data plot similar to the one on the Sahara Patient Report Form or using the equation for Z score given earlier in this chapter see Types of Reference Data Comparisons The results for each of the decade averages correspond to the results at the middle of the decade i e the results for the 20 30 year decade correspond to the results for age 25 The decade by decade Clinical User s Guide 5 13 5 Comparison of Patient Results to a Reference Database results therefore correspond to values for ages 25 35 45 etc For ages in between these the reference values are obtained by linear interpolation Thus the reference value for age 50 is the average of the age 45 and 55 values 5 14 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 System Care and Maintenance This chapter describes care and maintenance procedures on the Sahara Clinical Bone Sonometer It covers ordering supplies cleaning the unit printer
48. d as a T score and as an estimate of the Bone Mineral Density BMD in g cm of the calcaneus as measured by Dual Energy X ray Absorptiometry DXA 3 Contraindications The Sahara should not be used to assess patients whose skin is abraded and or have an open sore in the area that comes into contact with the system 4 Warnings e Prior to using Sahara users must read Individualization of Treatment and Relationship between Sahara Results and Heel BMD Results obtained by X Ray Densitometry below in order to properly interpret patient results e Never attempt to operate the Sahara unit with any power module other than the one provided with the system the Hologic Model Sahara Power Supply The power supply should only be plugged into a wall outlet that meets all electrical code requirements e This equipment is not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide 1 2 SAHARA Clinical Bone Sonometer Introduction 1 5 Precautions Use the Sahara Advanced Clinical Bone Sonometer only indoors in a clean dry environment Do not store the Sahara unit near a heat source or air conditioner Store the phantom near the unit Never store the QC phantom in the footwell with the transducer pads closed on it This will ruin both the phantom and the transducer pads The Sahara Clinical Bone Sonometer provides no protection against the harmful ingress entry of liquids
49. d to determine the mean or average value and the population standard deviation SD value for each Sahara output parameter Est BMD QUI BUA and SOS The mean value and standard deviation can be computed using most hand held scientific calculators and does not require sophisticated computer software Check that the SD value for the Est BMD is in the range of 0 070 to 0 150 g cm If the SD is not in this range it is possible that an error was made in the calculation of the SD Check that the mean value for the Est BMD is in the range of 0 400 to 0 700 g cm If the mean value is not in this range it is possible that an error was made in the calculation 5 12 SAHARA Clinical Bone Sonometer Comparison of Patient Results to a Reference Database 5 of the mean Note that any values may be entered into the Sahara system for the mean and SD and there may be populations for which values outside of these ranges are valid but most populations should have values that fall in these ranges Enter the mean and population SD values into the Sahara system using the procedure described in the preceding section For the first patient evaluated perform the T score calculation manually using the equation given earlier in this chapter see Types of Reference Data Comparisons in order to check that the mean and population SD were entered properly Guidelines for Development and Use of Age Dependent Reference Values A minimum of 50 subjects for e
50. d with the Sahara system for additional information 9 Patient Counseling Information Patient Information Brochures are supplied with the Sahara system These brochures give a brief summary of the importance of bone density testing and information about the Sahara Clinical Bone Sonometer 10 Conformance to Standards There are no known potential adverse effects of this device on health In fact this device uses ultrasound power levels lower than standard imaging ultrasound devices which are widely used and accepted No adverse events have been reported for the Sahara Clinical 1 6 SAHARA Clinical Bone Sonometer Introduction 1 Bone Sonometer during clinical use either from the clinical studies or from systems installed internationally Non clinical testing demonstrated conformance to voluntary safety UL2601 1 EN 60601 1 2 1993 CSA C22 2 No 601 1 M90 electromagnetic compatibility EN 55011 Group I Class B IEC 801 2 1991 IEC 801 3 1984 IEC 801 4 1988 and ISO ISO 9001 standards 11 How Supplied The Sahara shipping package includes the following One Sahara Ultrasound system One Power Supply and One Power cord One Positioning aide One QC Phantom Training Video The Sahara User Video Guide Starter supplies including Sahara Ultrasound Coupling Gel 2 tubes Transducer Towelettes 1 pkg Dry wipes 1pkg Pinter paper 2 rolls Ultrasound exam paper 1pkg Documents package containing User s Guide Supplie
51. displayed 2 12 SAHARA Clinical Bone Sonometer Initial Set Up 2 Set Language You may now can choose between different languages to be used on the SAHARA display Use the following procedure 1 Press Program on the SAHARA keypad Press 4 on the SAHARA keypad Press 2 on the SAHARA keypad Press Enter on the SAHARA keypad Press 9 on the SAHARA keypad Press 8 on the SAHARA keypad Sl ON CANO Press Enter on the SAHARA keypad The language menu will appear on the display English 1 Yes 2 No By continually pressing 2 No you can cycle through the following languages ENGLISH PORTUGUESE ITALIANO DEUTSCH FRANCAIS SLOVIK ESPANOL CROATIAN 8 Atany time you press 1 Yes the SAHARA will use that language on its display and in its printouts The program returns you to the Gel Pad menu displayed in the selected language Gel Pads Press OPEN Notes 1 If you cycle through all the languages by press 2 No after the CROATIAN language selection you will be returned to the Gel Pad menu 2 The major display modes as well as the SAHARA report printouts will be translated into the selected language Error messages appear in the English language at this time Clinical User s Guide 2 13 2 Initial Set Up 2 14 SAHARA Clinical Bone Sonometer Quality Control 3 Quality Control This chapter describes how to perform the Quality Control QC procedure on the Sah
52. e pads from the unit to clean dirt or stains Do not touch the transducer pads with any sharp objects as cuts or tears in the pads will effect system performance Replace torn cut or damaged pads immediately following the procedures described below Inspect the pads occasionally looking especially at the surfaces that contact the heel Replace pads if there is damage pitting tears cuts to these surfaces Transducer Pad Discoloration The transducer pads will discolor to a dark red purple or black if left in contact with the phantom supplied with the instrument Customers are alerted to this fact in the Clinical User s Guide in several places If the phantom and transducer pads are left in contact with one another for an extended period discoloration of the pads may occur Minor discoloration particularly on the edges of the pads has no impact on the performance of the machine In the event of major discoloration of the pad faces it may be necessary to replace both the pads and phantom If QC continues to pass after discoloration occurs the discoloration is merely cosmetic If however QC failures occur at the same time 6 4 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 major discoloration is noticed the pads require replacement and the instrument must be recalibrated Additionally check the phantom for deformity in the area of pad phantom interface If the phantom is noticeably deformed a new phantom is necessa
53. ed by the physician who is aware of all of these factors See Chapter 5 Patient Measurement for further information regarding monitoring of bone loss with Sahara Other than as indicated in the Contraindications and Warnings sections above there are no specific populations for which Sahara should not be used Guidelines for the development and use of reference ranges for populations other than Caucasian females for which reference ranges are supplied by Hologic are given in Chapter 6 of the Advanced Clinical User s Guide for the Sahara Clinical Bone Sonometer Relationship between Sahara Results and Heel BMD Results obtained by X Ray Densitometry Sahara measures the speed of sound SOS in m s and broadband ultrasonic attenuation BUA in dB MHz of an ultrasound beam passed through the calcaneus heel and combines these results linearly to obtain the Quantitative Ultrasound Index QUI and an Estimate of a patient s heel BMD While ultrasound parameters do not directly measure BMD BUA and SOS results are correlated 0 82 0 85 with heel BMD results obtained by the standard Dual Energy X ray Absorptiometry DXA technique as are results for the combined QUI parameter R 0 85 Thus an estimate of heel BMD results is obtained by a simple linear re scaling of the QUI parameter into heel BMD units in g cm The level of correlation R 0 85 between Sahara and DXA heel BMD results is similar to that observed between other accepted method
54. ed into Estimated BMD in units of g cm in order to simplify the interpretation of results by the physician Estimated BMD results may be compared to US Caucasian female reference values or to user defined reference values if available for other populations in order to assess the bone status of the patient relative to sex and race matched norms The measurement is taken with the patient seated and their foot positioned and secured in the Sahara system Soft rubber pads are brought into contact with either side of the heel and the measurement is performed by passing sound waves through the heel An ultrasound coupling gel is used between the pads and the patient s skin No water bath is Advanced Clinical User s Guide 1 9 1 Introduction necessary and the entire procedure including patient positioning takes only a few minutes Note that the use of coupling gel is critical because it eliminates air at the interface between the pads and the skin which would otherwise severely inhibit the transmission of sound waves To ensure proper operation use only the couplant gel provided by Hologic labeled Sahara Ultrasound Coupling Gel Other gels particularly those that are water based will adversely affect system performance giving inaccurate and or inconsistent results The system design provides for a highly repeatable method of positioning the foot with respect to the measurement device The lower leg is immobilized by a positi
55. elationship Between Sahara Results and Risk of Fracture below should be a factor in patient management decisions Because osteoporosis is a multifactorial disease consideration of all relevant risk factors is important in the evaluation of a patients Other risk factors besides BMD and T score include age previous fractures frame size smoking etc For example a 45 year old patient with a T score of 2 7 and a 75 year old patient with the same T score of 2 7 have drastically different clinical status and need to be evaluated appropriately Similarly there is no clinical distinction between two patients with T scores of 2 49 and 2 51 if they have the same age and have no other risk factors Other risk factors besides T score 1 14 SAHARA Clinical Bone Sonometer Introduction 1 and age include previous fractures frame size smoking etc See the Physician Learning Series included with the Sahara system for additional information Ls Grampp H K Genant A Mathur P Lang M Jergas M Takada C C Gluer Y Lu and M Chavez Comparisons of Noninvasive Bone Mineral Measurements in Assessing Age Related Loss Fracture Discrimination and Diagnostic Classification J Bone and Miner Res Vol 12 pg 697 711 1997 Kanis J et al Osteoporosis Int Vol 4 pg 368 381 1994 Relationship between Sahara Results and Risk of Fracture It has been demonstrated in a number of large multi center prospective clinical studies t
56. elay incurred by the sound waves as they travel through the transducer pads by making a similar measurement without the heel 1 with the two pads touching one another in order to determine the time delay due to the heel alone The time t the ultrasound signal takes to go through the heel alone is the propagation time of the ultrasound going through the heel and the transducer pads minus the propagation time measured with the pads touching and with no heel interposed Sahara automatically measures the width of the heel w using a micrometer attached to the transducers The SOS value is then equal to w t and is measured in meters per second m s The range observed with Sahara in a typical population is approximately 1450 1700 m s with young healthy subjects having higher SOS values than older or osteoporotic subjects Advanced Clinical User s Guide 1 11 1 Introduction Figure 1 3 SOS Measurement Transmission of Signal gt Receipt of Signal t Time gt Width SOS w t Broadband Ultrasound Attenuation BUA During early investigations of bone with QUS it was observed that bone attenuated high frequency sound waves much more than low frequency sound waves A linear relationship Fig 1 4 was observed for the attenuation in decibels or dB of ultrasonic waves in the frequency range of 0 2 to 0 6 MHz The slope of the linear regression of the ultrasonic attenuation vs frequency in this range is defined to be
57. ent of the mean value for the population studied Est Heel BMD 0 014 g cm 4 18 SAHARA Clinical Bone Sonometer Patient Measurement 4 Considerations for Patient Monitoring General Considerations For any type of bone densitometry equipment the frequency of use for monitoring of individual patients is dependent on a number of factors These factors include the precision of the device and the expected rate of BMD loss or gain which is in turn dependent on the status of the individual patient For example the changes expected due to aging or disease progression are quite different than those that could be expected for patients undergoing therapeutic intervention Furthermore the expected changes in BMD for subjects on therapeutic regimens is highly dependent on the type of treatment used e g hormonal replacement therapy calcitonin bisphosphonates etc Subjects on certain treatments for other conditions e g corticosteroids which are known to rapidly degrade BMD are also subject to special consideration Results of an initial baseline evaluation of BMD are also important as a patient with high BMD may not need to be evaluated as frequently as a patient with low BMD Therefore decisions regarding follow up time using Sahara must be individualized taking into account the patient s age disease status treatment status baseline BMD results and other risk factors The physician who is aware of all of these factors is thus the mos
58. erformed enter the QAB and QAS values on the log sheet in the QAB Rel Units and QAS Rel Units columns respectively Make sure that the results are entered into the row labeled with the corresponding day of the month i e the results obtained on the seventh day of the month are entered in the row with a 7 at the left side The results can then be plotted on the graph on the right side of the log sheet The day of the month is indicated along the horizontal axis on each graph with shading of alternate days to assist in plotting The measurement value is indicated on the vertical axis of each graph with breaks in the shaded areas to assist in plotting Finally the area between the two horizontal dashed lines indicates the normal acceptable range for measurement results Note that the PASSED indication on the Sahara control panel screen indicates that the results will be in the acceptable range on the plot QC results may occasionally fall outside of the normal range In most cases QC measurements that fall outside of the acceptable range are caused by a phantom that is not stabilized at room temperature leading to a REPEAT message rather than a PASSED message If the phantom has definitely stabilized at room temperature for more than one hour and the system returns a REPEAT message then it is recommended that the results be recorded in the log and plotted to document the QC failure See the System Care and Maintenance chapter in this manua
59. es 1 Fill in the biographical information for the patient in the spaces provided 2 Enter the results of the measurement Est BMD and T score as reported on the LCD screen 3 Staple the printout from the internal strip printer to the Report Form where indicated to provide a permanent record of results and to insure that no transcription errors were made 4 Plot the patient result on the graph of the age dependent reference values and estimate the corresponding Z score for the patient as described below 5 Record the estimated Z score on the form Estimating the Z score and Plotting Patient Results vs Age Dependent Reference Values Z scores can be manually computed using the age dependent reference ranges given in this section of the User s Guide and can be estimated from the Patient Report Form as follows Mark the plot at the point corresponding to the age and Est BMD value for the patient The curves shown on the plot correspond to the mean BMD vs age middle curve and 1 and 2 population standard deviations above the mean and below the mean curves above and below the middle curve If a patient s result falls exactly on the middle curve the Z score is 0 0 and the patient s Est BMD is equal to the mean value for Caucasian female subjects of the same age If the patient s result falls exactly on the upper most curve the Z score is 42 0 because it is 2 standard deviations above the age matched mean middle curve
60. es The calcaneus heel a bone that is 75 90 cancellous bone by volume and is readily accessible because of the small amount of soft tissue surrounding it is particularly attractive for studies aimed at the identification and or assessment of patients at risk QUS is a modality particularly well suited for the examination of cancellous bone of the heel 1 8 SAHARA Clinical Bone Sonometer Introduction 1 QUS results obtained using the Sahara system are correlated to heel Bone Mineral Density BMD in g cm results obtained by Dual energy X ray Absorptiometry DXA the most widely used technique for assessing BMD Thus Sahara ultrasound results can be converted into DXA equivalent units g cm in order to be more easily interpreted by physicians The Sahara system therefore reports the Estimated BMD of the heel in g cm as the default output result Because this Estimated BMD was obtained from ultrasonic measurements the ultrasound results may also be displayed if desired Access to the underlying ultrasound measurement results is especially important for Sahara system Quality Control where monitoring of the ultrasound parameters is critical for tracking of system performance Sahara Advanced Clinical System Overview The Sahara Advanced Clinical Bone Sonometer consists of a portable medical device the Sahara Clinical Bone Sonometer that when combined with the optional Advanced Clinical Software and an external computer pr
61. es will be displayed anytime the system is plugged in after being unplugged If the Power On Self Test fails see the System Malfunction section in Chapter 6 of this manual When the Self Test passes the Control Panel Screen displays Press ON to initialize Sahara The Control Panel Screen displays RAM Then Gel Pads Press OPEN Clinical User s Guide 2 5 2 Initial Set Up Printer Operation Follow the procedure below to load printer paper 1 Remove the printer cover by sliding the cover towards the rear Figure 2 4 Removing Printer Cover 2 Grasp the paper roll in your hand and feed the paper through the printer as shown in Step 1 of Figure 2 5 and Figure 2 6 Insert the paper into the paper slot where arrows indicate The paper should feed from the underside of the roll Figure 2 5 Threading Printer Step 1 dd NE ex IS Paper roll p x ML SSO 3 To feed the paper press the PRINT FEED button while the display screen is displaying Gel Pads press OPEN 2 6 SAHARA Clinical Bone Sonometer Initial Set Up 2 Figure 2 6 Feed Printer Paper 4 Place the paper roll into the printer tray Insert the paper roll in the tray as shown in Figure 2 7 and Step 2 of Figure 2 5 Figure 2 7 Insert Paper Roll Clinical User s Guide 2 7 2 Initial Set Up 5 Insert the paper through the slot in the printer cover and reinstall the cover
62. eter the Quantitative Ultrasound Index QUI sometimes referred to as Stiffness in the scientific literature Compared to the BUA or SOS parameters alone the combined QUI parameter is both more strongly correlated to the actual heel BMD obtained by the DXA and also has a reduced precision error QUI values normally range from 0 to 150 with higher values being obtained for young healthy subjects and lower values being obtained for older or osteoporotic subjects Because the QUI parameter is correlated to heel DXA BMD results a predicted or Estimated heel BMD result may be obtained by a simple re scaling of the QUI value Thus re scaled QUI value Estimated Heel BMD in g cm is reported by the Sahara system as the default output parameter Note that the QUI is a simple linear combination of the BUA and SOS which is formed merely to improve the estimate of heel BMD the default output of the Sahara system Relationship of Sahara Results and Heel BMD Results obtained by X Ray Densitometry Clinical studies have compared Sahara results to heel BMD assessed using the established Dual Energy X Ray Absorptiometry DXA technique These studies have shown that BUA and SOS the parameters directly measured by Sahara are correlated R 0 82 0 85 with DXA BMD Sahara QUI and Estimated Heel BMD values are also correlated R 0 85 to DXA BMD results This level of correlation is similar to that observed between other accepted
63. ew young adult BMD reference standard deviation proceed as follows 10 Press 1 The Control Panel Screen displays the following YAdit BMD SD 0 112 New Value 0 11 Insert the young adult BMD reference standard deviation then press ENTER 0 112 is the US Caucasian female population standard deviation and entering 0 0 disables the T score calculation 12 Repeat steps 3 10 to modify the young adult reference values for the QUI parameter if desired The US Caucasian female reference values for QUI are mean 103 9 SD 17 6 The Control Panel Screen displays the following Gel Pads Press OPEN Clinical User s Guide 5 11 5 Comparison of Patient Results to a Reference Database Development and Use of Reference Data Ranges for Specific Patient Populations The instructions given in the previous section describe how to enter user defined young adult reference ranges for populations other than US Caucasian females These young adult reference values are used to calculate T scores which are reported on the LCD display and on the strip paper printout obtained by pressing the PRINT FEED button on the keypad Age dependent reference ranges for Caucasian females are also supplied with Sahara as shown on the Patient Report Form from which Z scores are estimated In this section guidelines for development of young adult and age dependent reference values for other populations such as males or non Caucasian females
64. fness These reference values are also tabulated below Sahara Estimated Heel BMD Reference Data vs Age Est Heel BMD Standard Deviation yrs g cm g cm 0 581 0 112 0 555 0 112 0 562 0 112 Clinical User s Guide 5 7 5 Comparison of Patient Results to a Reference Database Sahara Reference Data vs Age 0 9 0 8 mean 1 pop SD 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 20 30 40 50 60 70 80 90 100 Est Heel BMD Age years Reference Data vs Age for Sahara Ultrasound Parameters Mean Value population SD Age yrs QUI Stiffness BUA SOS dB MHz m sec 76 71 14 80 74 82 14 80 75 89 14 80 74 13 14 80 65 02 14 80 59 81 14 80 5 5 85 7106 7 65 51 53 14 80 1514 5 30 43 95 65 65 17 65 49 82 14 80 1503 0 30 43 2 3 6 7 8 9 5 8 SAHARA Clinical Bone Sonometer Comparison of Patient Results to a Reference Database 5 Modify Young Adult Estimated BMD Reference Values optional Young adult reference values for Estimated Heel BMD are supplied automatically with each Sahara system These young adult reference values are specific to United States Caucasian female subjects and are used by the Sahara system to compute T score results for each patient measurement T score results are reported on the LCD screen and on the paper strip report along with the Estimated Heel BMD If a Caucasian female population is not appropriate f
65. for the Assessment of Bone Status 1 8 Sahara Clinical System Overview esses eene nennen eene ene 1 9 Ultrasound Measurements Using Sahara eeeeeeeereeenen een 1 10 Speed Of Sound SOS iicet tret ter ERROR UNA RENE FRE ERATES AE 1 11 Broadband Ultrasound Attenuation BUA sess 1 12 Estimated Heel BMD and the Quantitative Ultrasound Index QUI 1 13 Relationship between Sahara Results and Heel BMD Results obtained by X Ray Densitometty igiene nee REPE RR UU ODE ER REFERT 1 14 Relationship between Sahara Results and Risk of Fracture esse 1 15 E 1 17 Quality Control QC eene nennen nennen nente enne 1 18 Ultrasound Coupling gel 5 eter etr ate rhet E aeS 1 18 Controls and Indicators o eoe ive b eter ei dee re e eene bier sees 1 19 Specifications o 1 21 x Initial Examination Room 2 1 Unpacking the System eee onere cue utei e Rte eget ge 2 1 Setup and Fest edere eei pt eec ee rd eoe eade rd ede 2 3 Power On the System aU IUe been eed iR pn 2 3 Printer Operation ce tei E HEU espere ere da 2
66. formation 2 The QC phantom is used to calibrate the Sahara system for BUA and SOS measurement in the event of malfunction or if the transducers transducer pads or electronics are removed or replaced for any reason Note The QC phantom should be stored with the unit but not in the heel well The phantom and pads can both be ruined by long term contact with each other Ultrasound Coupling gel The Sahara Clinical Bone Sonometer requires the use of a special couplant gel that is supplied with the unit Standard ultrasound coupling gel will not provide the specified performance level To ensure proper operation use only the couplant gel provided by Hologic labeled Sahara Ultrasound Coupling Gel Other gels particularly those that are water based will adversely affect the measurement results Information on ordering Sahara Ultrasound Coupling Gel can be found in the System Care and Maintenance chapter of this manual 1 18 SAHARA Clinical Bone Sonometer Introduction 1 Controls and Indicators Figure 1 6 Power Status Light Figure 1 7 Control Panel This section describes the controls and indicators on the Sahara Control Panel The power status light is located at the rear of the instrument near the power connection This light will illuminate when power is applied to the unit Note that the Sahara instrument does not have an on off switch Power is applied by plugging in the power module Power Status Light
67. g material and located on the system 4 Carefully remove the system from the box by its handle and take the system out of the plastic bag 5 Locate the power supply and power cord and unwrap Note The box and packing materials should be saved in case the system has to be transported elsewhere or returned for service at some future date Setup and Test This section describes how to set up and test the Sahara Clinical Bone Sonometer Power On the System Follow the procedure below to complete the initial set up and test of the system Place the system on the floor where it will be used 2 Plug the power supply into the system the figure below shows the power supply connections Figure 2 2 Power Supply Connections Clinical User s Guide 2 3 2 Initial Set Up 3 Plug the power supply into the wall outlet The green power status light located near the power connection will illuminate Note Always perform Steps 2 and 3 in this order to avoid damaging the unit Figure 2 3 Power Status Light Power Status Light 4 The Control Panel Screen initially displays HOLOGIC Sahara Version x y Followed by Power On Self Test In Progress 5 Upon completion of the self test the Control Panel Screen displays Power On Self Test Passed OR 2 4 SAHARA Clinical Bone Sonometer Initial Set Up 2 Power On Self Test Failed The above messag
68. hat subjects with low BMD are at higher risk of fracture These studies have found that for elderly Caucasian female subjects age greater than 70 the risk of future fracture increases exponentially with decreasing BMD For hip fractures for example it was found that for each population standard deviation SD decrease in hip BMD there was a 2 to 3 fold increase in the incidence of fracture Note that a 2 fold increase in fracture risk per population SD decrease in BMD is referred to as relative risk of 2 0 The relative risk result is computed in terms of the difference in population SD units between a patient s results and the age matched mean value which is equivalent to the patient s Z score That is if the relative risk is 2 then a patient with a Z score of 1 has twice the risk of hip fracture compared to a patient with a Z score of 0 A patient with a Z score of 3 has 8 times 2 to the third power the risk of hip fracture The data from the fracture risk studies demonstrates that there is a gradient of risk which means that the risk of fracture increases continuously with decreasing BMD This is in contrast to the threshold concept in which risk suddenly increases below a specific BMD threshold value Because the results of these and many other studies are consistent with a gradient of risk rather than with a threshold care must be taken when applying threshold based classification criteria such as those proposed by the WHO
69. ith opposite sides of the patient s heel by means of a motorized caliper mechanism Each of the elastomer pads are acoustically coupled to the heel and to a sound transducer using Sahara Ultrasound Coupling Gel Inaudible high frequency sound waves produced by one of the sound transducers are transmitted through the heel and received by the opposite transducer Quantitative parameters describing the speed and attenuation of the sound waves in the heel are measured Advanced Clinical User s Guide 1 1 1 Introduction The Sahara Clinical Bone Sonometer estimates calcaneal heel Bone Mineral Density BMD in g cm from the measured ultrasound parameters Patient examination time is short with a measurement time excluding patient positioning of less than ten seconds 2 Intended Use Indications The intended use of the Sahara Clinical Bone Sonometer is to perform a quantitative ultrasound measurement of the calcaneus heel bone the results of which can be used in conjunction with other clinical risk factors as an aid to the physician in the diagnosis of osteoporosis and medical conditions leading to reduced bone density and ultimately in the determination of fracture risk Sahara measures the speed of sound SOS in m s and broadband ultrasonic attenuation BUA in dB MHz of an ultrasound beam passed through the calcaneus and combines these results linearly to obtain the Quantitative Ultrasound Index QUI The output is also expresse
70. ive within five days of receipt and we will arrange to enter into a written agreement or for your return of the equipment WARRANTY All Hologic products are warranted to the original purchaser or lessee Buyer to perform substantially in accord with their published functional specifications and to be free from defects in material and workmanship under normal use as prescribed in Hologic s Clinical User s Guide as of the date of Hologic s shipment Delivery This warranty shall extend for one year from the date of Delivery Hologic does not warrant that use of products will be uninterrupted or error free This warranty shall not apply to any product that is a repaired or altered other than by Hologic or its authorized service personnel b subjected to physical or electrical abuse stress neglect or misuse or c supplied on a pre release or as is basis If any product fails to meet this warranty Buyer s exclusive remedy and Hologic s entire responsibility shall be for Hologic at its discretion to repair or replace the non conforming product or part thereof or to return the price paid therefor Any item so replaced or repaired shall be subject to this warranty for the remaining warranty period or for thirty 30 days whichever period is longer Buyer must report any product failure during the warranty period and return the affected product or item in accord with Hologic s instructions EXCEPT AS MAY BE EXPRESSLY STATED IN A WRIT
71. l The printed report shows the Estimated BMD and he T score corresponding to the young adult mean and population standard deviation values The operator adds the patient biography referring physician operator name and foot measured left or right information to the printed report The printed report is obtained by pressing the PRINT FEED button on the Sahara control panel Note that the printed report will include the QUI BUA and SOS results as well as the Est BMD results if the PRINT FEED button is pressed when the ultrasound parameters are displayed on the LCD screen 5 2 SAHARA Clinical Bone Sonometer Comparison of Patient Results to a Reference Database 5 Figure 5 1 Press PRINT PR a Print Open Feed Prep 3 ERER Program C4 3C 5C s SAHARA Patient biography data name sex age etc should be noted on the printed report immediately after the exam Remember to indicate the foot measured Left or Right The printed report will have date and time of the exam HOLOGIC Serial No 87 E Estimated Heel BMD T Score Young Adult Clinical User s Guide 5 3 5 Comparison of Patient Results to a Reference Database Patient Report Form A tablet of Patient Report Forms is included with each Sahara system This form is provided to record patient information and measurement results and to allow patient results to be graphically plotted against age dependent US Caucasian female reference valu
72. l for further information if a PASSED QC result is not obtained Interpretation of QC Results A QC PASSED result indicates that the Sahara system is functioning properly Thus the system may be used for patient examinations regardless of the QAB and QAS values as long as the QC PASSED message is displayed at the conclusion of the QC procedure It is common to observe fluctuations in QC results within the normal acceptable range defined by the dashed lines on the Quality Control Log forms Occasionally QC results will be outside of these ranges and repeating the QC procedure after 1 hour will give acceptable results due to the stabilization of the phantom temperature In addition Sahara also automatically identifies QC results that are far enough outside of the acceptable range as to indicate either a procedural error no gel used for example or a system malfunction In such a case the system displays a Failed message refer to procedure above for details and the system should not be used to evaluate patients until an acceptable result is obtained or the unit is serviced Because the variation of the ultrasonic properties of the phantom due to temperature are larger than the Sahara unit s short and long term precision QC results provide a conservative estimate of the performance of the Sahara system This means that some fluctuation in phantom results would be expected even if the Sahara system had no variation For this reason
73. lation expressed in units of the young adult population standard deviation Mathematically the T score is defined as T P YA SDy where P patient results young adult average value SDy standard deviation of the young adult population Clinical User s Guide 5 1 5 Comparison of Patient Results to a Reference Database 2 Z score comparison Z score is defined as the difference in patient results from the mean results obtained in an age matched population expressed in units of the age matched population standard deviation Mathematically the Z score is defined as Z P AM SDAM where patient results AM age matched average value SDam standard deviation of the age matched population Reference Database Comparisons Available with Sahara Reports T score results are automatically calculated unless disabled by the user and reported with patient Estimated BMD on the LCD display T score results similarly included on the printout obtained by pressing the Print Feed button Z score results may estimated using the Patient Report Forms as described below or may be calculated manually by the operator using the equation above and the age dependent reference data When using the Patient Report Forms estimated Z scores are based on a Caucasian female population Internal Strip Printer Report Print each patient measurement immediately after it is taken see the Patient Measurement chapter of this manua
74. maintenance transducer pad care and maintenance and what to do if a problem occurs Ordering Supplies To order Sahara Ultrasound Coupling Gel towelettes dry wipes Examination paper printer paper or other supplies for the Sahara system International customers should contact their authorized Hologic distributor USA customers may complete a reorder card or call Hologic at 800 321 4659 Cleaning and Re Use The Sahara Clinical Bone Sonometer is a reusable device and is considered a noncritical device for infection control practices The transducer pads foot well control panel positioning aide and rest of the scanner are the surfaces of the Sahara unit that may be cleaned between use How Supplied Towelettes and dry wipes are supplied with the Sahara system for cleaning of gel from the transducer pads phantom and patient The towelettes supplied are standard baby wipes which are a commonly available over the counter product Additional towelettes may be purchased either from Hologic or at any local pharmacy or supermarket The dry wipes supplied Kim wipes manufactured by Kimberly Clark are a standard product commonly available from medical supplies dealers and medical supplies catalogs Additional dry wipes may be ordered from Hologic or purchased through your medical supplies dealer or catalog It is acceptable to substitute other equivalent brands of dry wipes Clinical User s Guide 6 1 6 System Care and Mainte
75. meter Patient Measurement 4 Sahara Patient Measurement Procedure Prepare Transducer Pads 1 Press the ON button The system initializes itself closes the transducer pads until they touch pauses momentarily and then opens them for gel application Figure 4 2 P TOP Print Open Feed Prep px Jp 3 3 rogram uer mere x CEDIC o ut canard CLINICAL BONE SOR METER Figure 4 3 Transducer Pads Touch li Clinical User s Guide 4 3 4 Patient Measurement Figure 4 4 Transducer Pads Ready for Gel Note If there is no operator action within ten minutes after ON is pressed the unit goes to Power Saver Mode the screen goes blank Press the ON key to return to the last screen The Control Panel Screen displays Gel Pads Press OPEN 2 Foreach transducer pad squeeze out about a one inch 2 5 cm bead of gel onto your finger Note Do not use a Q Tip examination glove containing talc or any other applicator that may introduce fibers or other foreign matter 4 4 SAHARA Clinical Bone Sonometer Patient Measurement 4 Figure 4 5 Gel Measurement Figure 4 6 Apply Gel Clinical User s Guide 4 5 4 Patient Measurement 3 Apply gel evenly on the face of the pad Note Itis important that the leading edge of the transducer pad is fully covered Figure 4 7 Leading Edge Gel Application Front View The Control Panel Screen displays Inse
76. methods for assessing BMD at the same anatomical site For Advanced Clinical User s Guide 1 13 1 Introduction example published studies have shown that standard posteroanterior PA DXA lumbar spine BMD results and spine BMD results obtained by the quantitative computed tomography technique have in vivo correlations of 0 83 The relationship between Sahara and DXA heel BMD results is linear with the average BMD values for a group of subjects obtained by either technique being clinically indistinguishable For individual patients however there may be differences between the Sahara Estimated Heel BMD and the DXA Heel BMD These differences arise due to several factors including the precision errors inherent in both Sahara and DXA results as well as the subject dependent differences between the ultrasound and DXA measurement methodologies for assessing bone Subject dependent differences between Sahara and DXA heel BMD results have a range equal to one standard deviation SD of a typical population of subjects of the same age The 9596 confidence interval for differences between Sahara and DXA heel BMD results is therefore 2 population SD s T scores which quantify the difference between a given patient s results and the mean results for a young adult reference group are reported in population SD units Thus patients assessed by Sahara and heel DXA will have results that are equal on the average but that differ by up to
77. mination Internal Strip Printer Report Sahara Clinical systems may obtain a printed report that includes the measurement results by pressing the PRINT FEED button on the Sahara control panel Note that the printed report will include the QUI BUA and SOS results as well as the Est BMD results if the PRINT FEED button is pressed when the ultrasound parameters are displayed on the LCD screen Figure 4 25 Press PRINT Print Open Feed Prep C3 C 2 JC 3 ecu 00 80 Ca fae o CC tcm C canard CLINICAL BONE SOR METER Patient biography data name sex age etc should be noted on the printed report immediately after the exam Remember to indicate the foot measured Left or Right The printed report will have date and time of the exam Clinical User s Guide 4 17 4 Patient Measurement Loca HOLOGIC Date 8 04 1997 Serial No 87 Est Heel BMD 0 340 g cm2 T Score 2 2 Estimated Heel BMD T Score Young Adult Patient Report Form Refer to Chapter 5 Comparison of Patient Results to Reference Values for information on use of the Patient Report Form Precision of Sahara Results The precision or reproducibility of Sahara results was determined by repeated patient measurements with complete re positioning between measurements Precision results are given in the table below in absolute units SD and in terms of the coefficient of variation C V which is expressed in perc
78. nance if Kim wipes are not available but it is NOT acceptable to use facial tissues which can leave residues and particles on the transducer pads Infection Control Hologic recommends the use of Cavicide disinfecting cleaner to clean the Sahara unit s surfaces between use Cavicide is a disinfecting cleaner that destroys pathogens and other microorganisms Cavicide is available by contacting the Metrex Research Corporation IL 800 841 1428 The chemical composition of Cavicide is Active Ingredients Diisobutylphenoxyethoxyethyl dimethyl benzyl ammonium chloride 0 25 Isopropanol 15 3096 Inert Ingredients 84 45 Total Cavicide has been tested on inanimate surfaces against e Staphylococcus aureus e Pseudomonas aeruginosa e Salmonella choleraesuis e Mycobacterium tuberculosis var bovis BCG e Methicillin Resistant Staphylococcus aureus MRSA e Vancomycin Resistant Enterococcus faecalis VRE e Trichophyton mentagrophytes e Herpes simplex virus types 1 and 2 e Human Immunodeficiency Virus HIV 1 e Poliovirus types 1 and 2 e Coxsackievirus 1 EPA Reg No 38526 1 EPA Est No 39234 WV 1 6 2 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 Cleaning Frequency The transducer pads and foot well should be cleaned after each patient or phantom measurement The rest of the scanner and positioning aide may be cleaned as necessary How to Clean Disinfect the Sahara Unit
79. nographic heel measurements to predict hip fracture in elderly women the EPIDOS prospective study Lancet Vol 348 pg 511 4 1996 Gluer CC Cummings SR Bauer DC et al Osteoporosis association of recent fractures with quantitative US findings Radiology Vol 199 pg 725 32 1996 System Components The key components of the Sahara Advanced Clinical Bone Sonometer system shown in Figure 1 5 include the ultrasound unit including positioning aid power supply power cord QC phantom Sahara Ultrasound Coupling Gel and an external desktop or laptop Windows based PC not shown The PC functions as a remote controller data base manager and data storage device for the ultrasound system A complete list of accessories and supplies for the Sahara system with the Advanced Clinical Software option is given in the Essential Prescribing Information above and also in Chapter 2 of this User s Guide 1 16 SAHARA Clinical Bone Sonometer Introduction 1 Figure 1 5 System Components Sahara Instrument Positioning Aid Sahara Ultrasound Coupling Gel QC Phantom a Power Supply A Power Cord Sahara External Computer Specifications The computer PC used with the Sahara Research System must meet the following minimum specifications The PC may be a desktop or a laptop with either a color or monochrome display Computers with more memory larger disks and faster processors are allowed and are likely to impro
80. o be observed for patients treated with corticosteroids Clinical User s Guide 4 19 4 Patient Measurement 4 20 SAHARA Clinical Bone Sonometer Comparison of Patient Results to a Reference Database 5 Comparison of Patient Results to Reference Values This chapter describes standard terminology used for comparison of patient results to reference ranges and the reference ranges supplied with the Sahara Clinical Bone Sonometer The Sahara system provides age dependent reference values for Caucasian U S females These reference values were obtained in a large multi center study in which Sahara results were obtained for 2208 Caucasian females at 9 clinical centers located across the U S For situations in which the Caucasian female reference values are not appropriate Sahara also provides the capability of entering user defined young adult reference values enabling automatic comparisons of patient results to these values if available Guidelines for development entry and use of reference values for specific populations are described It is also possible to disable the reporting of reference comparisons with the Sahara software for those cases in which no appropriate reference data exists Types of Reference Database Comparisons In general two kinds of comparisons to a reference database can be performed 1 T score comparison T score is defined as the difference in patient results from the mean results obtained in a young adult popu
81. on to ensure that the foot well and control panel are clean Also clean the rest of the scanner and positioning aid as necessary Clinical User s Guide 6 3 6 System Care and Maintenance Care and Maintenance of Transducer Pads Warning The Sahara system must be calibrated after removing or replacing transducer pads Therefore it is important not to remove the transducer pads unless necessary If the transducer pads become damaged and do need to be removed or replaced it is imperative that the instructions below be carefully followed to ensure proper system performance Never store the phantom in the unit footwell with the pads closed on it as this will destroy both the pads and the phantom Care of Transducer Pads Transducer pads should be cleaned removing all coupling gel after each patient or phantom measurement as specified in the measurement procedures in this manual Use the towelettes supplied with the Sahara system to remove gel from the pads and then the dry wipes supplied to dry the pads Note When cleaning the transducer pads it is acceptable to substitute other equivalent brands of dry wipes if Kim wipes are not available but it is NOT acceptable to use facial tissues which can leave residues and particles on the transducer pads that could degrade system performance Rubbing alcohol may also be used to remove built up dirt or stains on the pads followed by wiping with towelettes and dry wipes Do not remove th
82. oning aid fitted with moldable foam and a padded strap secures the leg into the positioning aid to set the proper leg angle Figure 1 1 Sahara Advanced Clinical System Ultrasound Measurements Using Sahara The term ultrasound refers to high frequency non audible sound waves Ultrasound measurements are made on the Sahara system by measuring the transmission of these sound waves through the heel The heel is positioned between a pair of sound transducers Fig 1 2 with one transducer transmitting the ultrasound signal and the other transducer receiving the signal after passage through the heel The transducers are acoustically coupled to the heel by elastomer transducer pads using Sahara Ultrasound Coupling gel which is applied to the transducer pads From the signal measured by the receiving transducer two parameters describing the nature of the received sound waves can be simultaneously determined Speed of Sound SOS and Broadband Ultrasonic Attenuation BUA 1 10 SAHARA Clinical Bone Sonometer Introduction 1 Figure 1 2 Sahara Measurement Geometry Sound Waves Speed Of Sound SOS SOS is defined as the speed of sound through the heel SOS is determined Fig 1 3 by measuring 1 the width of the heel and 2 the time delay between the initial transmission of the sound waves by one transducer and the receipt of the sound waves by the second transducer The Sahara system measures and corrects for the time d
83. or cuts in the surface especially the ends of the pad 4 Place the pad in the housing making sure the key on the pad is aligned to the correct slot see the figures below Pull on the end contacting the heel to finish seating and aligning the pad The figures below shows how to align the left and right transducer pads 6 6 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 Figure 6 4 Figure 6 3 Left Transducer Pad Right Transducer Pad Alignment Alignment 5 Apply Hologic Sahara Pad Installation Gel which is included in the pad replacement kit to the flat end of the pad before positioning it in place in the system Spread the gelevenly with your finger so that there is about a 1 16 inch 1 6 mm coating on the pad Be careful not to introduce air bubbles dirt or other contaminants see the figure below Clinical User s Guide 6 7 6 System Care and Maintenance Figure 6 5 Pad Gel Application 6 With gel applied screw the housing pad onto the transducer as far as it will go The guide mark on the Sahara enclosure should line up with the mark on the transducer housing see the figure below Repeat steps 1 6 for the other transducer pad Figure 6 6 Pad Guide Marks 7 With both pads installed the system should look like the figure below note the position of the leading edge of the transducer pads If the pads are not correctly 6 8 SAHARA Clinical Bone Sonometer System Care and Maintenance
84. or gel application Figure 3 1 Press ON Print Open Feed Prep pue 2 8 rJ e sse sen Lae pe CID sanar CLINICAL BONE SORGWETER 3 2 SAHARA Clinical Bone Sonometer Quality Control 3 Figure 3 2 Transducer Pads Touch Figure 3 3 Transducer Pads Ready for Gel Note If there is no operator action within ten minutes after ON is pressed the unit goes to Power Saver Mode the screen goes blank Press the ON key to return to the last screen 2 Press the PROGRAM button on the keypad then press the 1 button and then press ENTER This tells the system that a QC measurement is about to be made Clinical User s Guide 3 3 3 Quality Control Figure 3 4 Press Print Open Feed WEB INCHES GERE eror SAHARA The Control Panel Screen displays Gel Pads for QC Press OPEN 3 Foreach transducer pad squeeze out about a one inch 2 5 cm bead of gel onto your finger see the figure below Note Do not use a Q Tip examination glove containing talc or any other applicator that may introduce fibers or other foreign matter 3 4 SAHARA Clinical Bone Sonometer Quality Control Figure 3 5 Gel Measurement Figure 3 6 Spread Gel Clinical User s Guide 3 5 3 Quality Control 4 Apply gel evenly on the face of the pad Note It is important that the leading edge of the transducer pad is fully cove
85. or the subjects to be assessed it is possible to enter locally derived young adult reference values into the Sahara system Once entered into the system these local user defined reference values will then automatically be used to compute T score results for subsequent patient measurements It is also possible to disable the T score calculation if the US Caucasian female population is not appropriate and local reference values are not available To disable the T score calculation enter 0 0 for both the Young Adult Mean Value and the Young Adult Population SD in the procedure described below Once disabled the T score will not appear on the LCD screen or on the paper strip printout NOTE If the young adult reference values have been modified from the original factory set Caucasian female values the T score based on US Caucasian female reference data annotation at the bottom of the paper strip printout will no longer appear This annotation will re appear if the reference values are re set to the US Caucasian reference values as given in the procedure below and in Section 5 of this User s Guide If local young adult reference values are available and comparison of patient results to these values is desired manually enter the young adult reference values into the Sahara system following the procedure below Guidelines for development of reference values are described in the next section To set the young adult reference values in your S
86. ovides a Microsoft Windows based workstation and full graphics printer The Hologic Sahara Advanced Clinical Software Option installed on the external PC provides a data base for storage and retrieval of patient records For operator convenience the instrument may be controlled using a mouse from the computer rather than by pressing the keys on the Sahara unit In addition full size patient reports including patient history can be obtained This software option may be installed at any time before or after system installation as each Sahara system has a standard communication port installed at the factory for communication with the optional Advanced Clinical Software computer The system may be used either with or without the external computer at any time so long as it is understood that the computer must be connected prior to any patient examination for which the operator wishes that the results be stored in the computer database If the computer is disconnected the Sahara Clinical System operates exactly the same as the standard system without the Advanced Clinical Software Option Sahara measures the ultrasonic Speed Of Sound SOS and Broadband Ultrasound Attenuation BUA of the calcaneus heel and combines these two measured values to obtain a parameter referred to as the Quantitative Ultrasound Index QUI sometimes referred to as stiffness in the scientific literature The QUI Stiffness value obtained for a patient is then convert
87. r Jam If any of the following printer problems occur the printer paper jams or the edge of the paper frays or tears or the printer does not feed paper continuously stop further printing and perform the procedure below to obtain measurement results and clear the printer In the event of a printer jam before unplugging the machine follow the procedure described below in order to obtain the results 1 Press ON to clear the error message from the screen The screen will display 2 Press the key once This will display the QUI and T Score results from the measurement calculated before the printer jam Write these results down Once the instrument is unplugged these results will be lost 3 Press the key again The BUA and SOS results will be displayed Write these results down 4 Unplug the unit 5 Remove the printer cover from the machine refer to Printer Operation in this chapter 6 Remove as much paper as possible Tweezers or long nose pliers may be necessary for this step A straightened paper clip may be used if those tools are not available 7 Clip off the end of the paper roll with scissors to obtain a straight edge 8 Plug the unit back in Refer to the section Initial Set Up to reload the paper 6 22 SAHARA Clinical Bone Sonometer System Care and Maintenance 6 Printer Operates but Does Not Print If this occurs the printer paper may be installed backwards The
88. red Figure 3 7 Proper Amount of Gel on Transducer Pad Leading Edge Front View 5 When gel has been applied to both transducer pads press the OPEN PREP button The scanner opens the transducer pads to the fully open position Figure 3 8 Press OPEN PREP Print Open Feed Prep zy cx tec C C23 OF canard CLINICAL BONE SOKO METER The Control Panel Screen displays 3 6 SAHARA Clinical Bone Sonometer Quality Control Insert Phantom Press MEASURE 6 Place the QC phantom in the Sahara Position the phantom so that its rounded end is snugly in the positioning contour heel cup and the label is on top Figure 3 9 QC Phantom Position 7 Press the MEASURE button The scanner performs the measurement then automatically opens the transducer pads Clinical User s Guide 3 7 3 Quality Control Figure 3 10 Press MEASURE Print Open Feed Prep Enn 2 1 GEUES NC END ET x 9 o eran sauand CLINKCAL BONE SOR METER 8 The Control Panel Screen displays the following Remove the QC phantom Remove Phantom 1 Press PREP 2 Clean 9 Press OPEN PREP The transducer pads return to the ready position Figure 3 11 Press OPEN PREP Print Open Feed Prep CESA E ame e canard CLINICAL BONE SOR OMETER 10 Carefully clean and dry the phantom and the transducer pads Use towelettes s
89. rovided that the third party first agrees in writing to be bound by these terms and to permit Hologic to enforce them against the third party The Buyer has no other right to sell assign transfer copy or sublicense Software Any failure by the Buyer to comply with the terms of this license will cause this license to terminate automatically The Buyer may terminate this license by returning the Software and all copies thereof to Hologic LIMITATION OF LIABILITY IN NO EVENT SHALL HOLOGIC BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL LOSSES DAMAGES OR EXPENSES UNDER ANY THEORY INCLUDING BUT NOT LIMITED TO NEGLIGENCE EVEN IF INFORMED OF THE POSSIBILITY THEREOF AND INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS DATA OR USE ARISING OUT OF ANY USE OF THE EQUIPMENT OR BUYER S ACQUISITION OF ANY HOLOGIC PRODUCT UNDER NO CIRCUMSTANCE SHALL HOLOGIC BE LIABLE FOR ANY AMOUNT GREATER THAN THE PRICE HOLOGIC HAS RECEIVED Hologic retains the right to void all warranties obligations and licenses if payment for the subject equipment or Software is not received in accord with the applicable terms of sale or lease SAHARA Clinical Bone Sonometer Table of Contents Introduction and Background eee ecce esee ee ee eese sese es seeessseeessseeessse L Essential Prescribing Information esses esee enne nennen nennen enne nene 1 1 Quantitative Ultrasound QUS as a Tool
90. rt Foot Press MEASURE 4 When gel has been applied to both transducer pads press the OPEN PREP button The scanner opens the transducer pads to the fully open position 4 6 SAHARA Clinical Bone Sonometer Patient Measurement 4 Figure 4 8 Press OPEN PREP Print Open Feed Prep C2 63 rogram a usc e 558 9 o snunn A CLINICAL BONE SOR METER Position Patient 1 The patient should be seated in a stationary straight back chair approximately 12 to 18 inches 30 to 46 cm from the scanner Figure 4 9 Patient Position Clinical User s Guide 4 7 4 Patient Measurement 2 Ask the patient to remove their shoes socks nylons etc so that the foot is bare If the patient s skin in the area to be tested is abraded and or has an open sore do not measure that heel 3 Clean the sides of the heel to be measured using towelettes supplied in the Accessories Kit then dry thoroughly with dry wipes 4 Place exam paper on the bottom of the scanner foot well 5 Place the patient s foot into the foot well Ensure that the middle of the heel is snug against the center of the positioning contour heel cup and that the foot is positioned in the well see the figures below with the positioning line aligned with the gap between the patient s second and third toe Figure 4 10 Patient Leg Position 4 8 SAHARA Clinical Bone Sonometer Patient Measurement 4 Figure 4 11 Pa
91. ry Transducer pads will slowly and evenly turn yellow over the course of several months This is due to UV ultraviolet degradation of the surface of the pads and does not affect the instrument s performance Removal Replacement of Transducer Pads Note Transducer pads must always be replaced in pairs Do not replace one pad without replacing the other Transducer pads may be removed cleaned and re installed if they are excessively dirty Follow the procedure for replacing the pads below re installing the same pads after cleaning with towelettes and dry wipes rather than installing new pads If one or both transducer pads has become damaged cut torn or has become pitted replace both transducer pads following carefully the procedure below This procedure includes system re calibration which must be performed any time the pads have been removed or replaced 1 Unscrew the transducer pad housing see the figure below Figure 6 1 Remove Transducer Pad Housing 2 Clean the transducer face see figure below with towelettes and dry wipes making sure not to leave any residual coupling gel on the transducer face Clinical User s Guide 6 5 6 System Care and Maintenance Figure 6 2 Cleaning Transducer Face 3 Locate the bag containing the replacement transducer pads and remove one pad Clean the new pad with towelettes and dry with dry wipes to remove any dirt lint etc Visually inspect the pad looking for tears
92. s association of recent fractures with quantitative US findings Radiology Vol 199 pg 725 32 1996 Quantitative Ultrasound QUS as a Tool for the Assessment of Bone Status Ultrasound is well established in the medical community as a safe and cost effective diagnostic modality Until recently medical ultrasound has primarily given clinicians only qualitative images of soft tissue However it is also possible to use ultrasound to obtain quantitative information about bone status In comparison to traditional techniques for assessment of skeletal status including radiographs x ray absorptiometry and computed tomography which involve exposure to radiation QUS is a quick low cost and radiation free diagnostic tool These advantages are especially important in the clinical environment for which Sahara was designed where unnecessary operator and patient x ray exposure for example are undesirable Many bone diseases including osteoporosis degrade cancellous or trabecular bone much earlier and to a greater extent than cortical bone Turnover of cancellous bone is about eight fold higher than of cortical bone thus age and disease related bone loss are more readily apparent in cancellous bone compartments Therefore it is becoming more widely accepted in the medical community that skeletal sites with a high percentage of cancellous bone are important examination sites for patients at risk for osteoporosis and other metabolic bone diseas
93. s for assessing BMD at the same anatomical site For individual patients there may be differences between the Sahara and DXA Heel BMD results These differences arise due to several factors including the precision errors inherent in both Sahara and DXA results as well as the subject dependent differences between the ultrasound and DXA measurement methodologies for assessing Advanced Clinical User s Guide 1 5 1 Introduction bone For individual patients differences between Sahara and DXA heel BMD results have a range equal to one standard deviation SD of a typical population of subjects of the same age The 9596 confidence interval for differences between Sahara and DXA heel BMD results is therefore 2 population SD s or 2 T scores This means that individual patients may be classified differently by Sahara compared to DXA when using the World Health Organization WHO classification criteria The WHO criteria classify patients with BMD values more than 2 5 SD s below the young adult mean T score below 2 5 as osteoporotic and patients with T scores between 1 and 2 5 as osteopenic However the differences in T score results obtained by Sahara and heel DXA are similar to or smaller than the differences found when patients are assessed by any other two accepted methods for assessing BMD of the same anatomical site Note that differences for an individual patient when assessed at two different anatomical sites can be even larger due
94. s ree ee 6 3 Care and Maintenance of Transducer Pads s essen 6 4 vi SAHARA Clinical Bone Sonometer Table of Contents Care of Transd cer Pads nocet eee dte detenti ete Geese 6 4 Transducer Pad Discoloration esee ener enne 6 4 Removal Replacement of Transducer Pads sss 6 5 Cahbrate System ze EEE ion en i ie ee Ren 6 9 System Calbratiob tee eae Ms EEEE E EE 6 9 Calibration Failure ie RE n Het pr Reo Matt aes 6 17 Printer Operation teet o reete e REDE EE REPRE 6 18 Display Setial Number etum Uie eU RUNE hus 6 21 What to do in Case of Trouble sss nennen nene 6 22 Acquiring Results After a Paper Jam Clearing a Printer Paper Jam 6 22 Printer Operates but Does Not 6 23 POWer Problem eere i tepidis re ete deed 6 23 System Malfunction and Error 6 23 Printing the Exception Report eene 6 24 Quality Control Problem nct eite et rie PRI E 6 25 Patient Measurement Problems essere nennen nennen 6 26 Asterisk after Estimated BMD result Est BMD 0 500 g cm uni Eee 6 26 Invalid Measurement Repeat essere trennen 6 26 Measurement Out of Range 5 eiecti eter te tire tt er eti et tete god 6 27 Figures Figure 1 1 Sahara Clinical System
95. s reorder cards Installation Warranty and Post Warranty Service Information Sheet QC Log Forms 1 tablet Patient Report Forms 1 tablet Patient Information Brochures 1 pkg Sahara Physician Learning Series Sahara Advanced Clinical Software Package including One User s Guide for the Sahara Advanced Clinical Software One Communications Cable connects PC to Sahara system Sahara Advanced Clinical Software on Floppy Disk One Personal Computer PC if purchased from Hologic 12 Operator s Manual Attached Advanced Clinical User s Guide 1 7 1 Introduction 13 References LS Grampp H K Genant A Mathur P Lang M Jergas M Takada C C Gluer Y Lu and M Chavez Comparisons of Noninvasive Bone Mineral Measurements in Assessing Age Related Loss Fracture Discrimination and Diagnostic Classification J Bone and Miner Res Vol 12 pg 697 711 1997 Kanis J et al Osteoporosis Int Vol 4 pg 368 381 1994 Bauer DC Gluer CC Cauley JA Vogt TM Ensrud KE Genant HK Black DM Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women Archives of Internal Medicine Vol 157 pg 629 633 1997 Hans D Dargent Molina P Schott AM et al Ultrasonographic heel measurements to predict hip fracture in elderly women the EPIDOS prospective study Lancet Vol 348 pg 511 4 1996 Gluer CC Cummings SR Bauer DC et al Osteoporosi
96. sitivity of Sahara results to risk of fracture the data from Bauer et al were re analyzed after using the Walker Sonix heel ultrasound results to predict Sahara results for all study subjects In this analysis Sahara results were estimated using the slope intercept and RMSE describing the relationship between Sahara and Walker Sonix results as determined in the Sahara clinical study The estimated Sahara results for all study subjects were then analyzed in exactly the same manner as for the original study data resulting in a relative risk value of 1 84 Receiver operator characteristic ROC curves were constructed indicating that there were no clinically significant differences between the discriminatory abilities of Sahara and Walker Sonix results In summary large prospective studies have thus demonstrated the strong exponential relationship between heel ultrasound and x ray results and the risk of fracture The strong relationship between Sahara and Walker Sonix results suggests that Sahara results will be equally predictive of fracture risk For additional information see the Physician Learning Series included with the Sahara system Bauer DC Gluer CC Cauley JA Vogt TM Ensrud KE Genant HK Black DM Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women Archives of Internal Medicine Vol 157 pg 629 633 1997 Hans D Dargent Molina P Schott AM et al Ultraso
97. t essere 6 7 Figure 6 5 Pad Gel Application enkei rennen eene 6 8 vili SAHARA Clinical Bone Sonometer Table of Contents Figure 6 6 Pad Guide Marks rennen 6 8 Figure 6 7 Pads Installed 6 9 Figure 6 8 Press ete eee p neto ree UR RHET Ert 6 10 Figure 6 9 Transducer Pads Touch esssseeeeeeeeeeeeen eene 6 10 Figure 6 10 Transducer Pads Ready for Gel sese 6 11 Figure 6 11 Press PROGRAM 2 ENTER eee nennen eene 6 11 Figure 6 12 Measure Gel nette utter are he E eben 6 13 Figuie6 13 Apply Gelnar ote diete tutes Uis URGES 6 14 Figure 6 14 Gel Application rennen tenete nenne 6 14 Figure 6 15 Press rennen eene nennen trennen 6 15 Figure 6 16 QC Phantom in Position esee 6 15 Figuie 6 17 Press MEASURE reete ertt p eed teg eet ede 6 16 Figure 6 18 Prest OPEN PREP rn nene 6 16 Figure 6 19 Removing Printer Cover nene 6 18 Figure 6 20 Threading Printer Paper nennen 6 18 Figure 6 21 Reed Printer Paper 6 19 Figure 6 22 Insert Paper 6 19 Figure 6 23 Printer Cover Replaced
98. t appropriate judge of how frequently a patient should be evaluated with bone densitometry equipment Considerations for Monitoring with Sahara For Sahara the absolute precision error for Est BMD results is 0 014 g cm which corresponds to about 2 4 times the annual rate of loss in the U S Caucasian female reference population 0 0057 g cm yr For comparison standard Dual Energy X ray Absorptiometry DXA measurements of the spine or hip have a precision error equal to about 1 to 2 times the annual rate of loss in a reference population Bone loss rates may be higher for individual patients immediately after menopause From the absolute precision error the magnitude of the minimum change which can be determined with 95 confidence can be calculated min significant change 95 conf 1 96 x 1 414 x 0 014 g cm 0 0388 g cm This minimum significant change corresponds to about 7 of the mean BMD value for a 55 year old caucasian female This amount of change is approximately what might be expected after 2 to 3 years of therapy with commonly available treatments Some patients will have larger BMD increases and some will have smaller increases and therefore follow up time will depend on the patient s individual clinical situation Changes of this order of magnitude may also be expected in as little as 6 months to a year for patients treated for a variety of conditions such as hyper parathyroidism and hyper thyroidism and may als
99. then the 2 button and then ENTER on the control panel This initiates calibration of the system Figure 6 11 Press PROGRAM 2 Print Open amc Ca Cj CURD SAHARA Program The Control Panel Screen displays the following message 6 Clinical User s Guide 6 11 6 System Care and Maintenance CAUTION Enter calib procedure 1 Yes 2 No 3 Press 1 to start calibration if 2 is pressed the system will return to the Gel Pads Press OPEN screen Note The phantom should not be in place at this point The Control Panel Screen displays the following message Calib takes 15 min Continue 1 Yes 2 No 4 Press 1 to continue calibration if 2 is pressed the system will return to the Gel Pads Press OPEN screen The Control Panel Screen displays the following message Phantom Label BUA 0 5 Enter the BUA number from the phantom label and press ENTER The Control Panel Screen displays the following message Phantom Label SOS 0 6 Enter the SOS number from the phantom label and press ENTER The Control Panel Screen displays the following message Phantom Label Width 0 7 Enter the width number from the phantom label and press ENTER The Control Panel Screen displays the following message Phantom Label S N 0 8 Enter the serial number from the phantom label and press ENTER The Control Panel Screen displays the following message
100. tient Foot Position Figure 4 12 Heel Position 6 Position the patient s leg at about the same angle as the positioning aid Clinical User s Guide 4 9 4 Patient Measurement 7 Place the positioning aid down on the leg leaving it slightly loose about enough room to place two fingers between the leg and the positioning aid Figure 4 13 Positioning Aid Slightly Loose 8 Adjust the leg to the angle of the positioning aid by moving the Sahara the scanner and calf should line up The figures below show correct and incorrect leg angle Figure 4 14 Correct Leg Angle front to back 4 10 SAHARA Clinical Bone Sonometer Patient Measurement 4 Figure 4 15 Incorrect Leg Angle system too close Figure 4 16 Incorrect Leg Angle system too far 9 Ensure that the patient s leg is straight see the figures below and push the positioning aid down firmly to insure it is snug Clinical User s Guide 4 11 4 Patient Measurement Figure 4 17 Correct Leg Position side to side Figure 4 18 Incorrect Leg Position side to side 4 12 SAHARA Clinical Bone Sonometer Patient Measurement 4 Figure 4 19 Incorrect Position of Toes 10 With the positioning aid down tight attach the positioning aid strap firmly around the leg Figure 4 20 Positioning Aid Strap 11 Ensure that the patient is sitting straight up with their back against the back of the chair and hands folded in their l
101. to physiological and anatomical differences between the various sites Itis widely accepted that while any measure of BMD is a strong indicator of risk for osteoporosis and osteoporotic fractures classification by the WHO criteria is dependent on the measurement technique and even more so on the measurement site Thus an understanding of the potential differences in T score results obtained by different techniques should be considered when applying the WHO classification criteria When using threshold based criteria to classify patients the continuous exponential increase in fracture risk with decreasing BMD see Relationship Between Sahara Results and Risk of Fracture below should be a factor in patient management decisions Because osteoporosis is a multifactorial disease consideration of all relevant risk factors is important in the evaluation of a patients Other risk factors besides BMD and T score include age previous fractures frame size smoking etc For example a 45 year old patient with a T score of 2 7 and a 75 year old patient with the same T score of 2 7 have drastically different clinical status and need to be evaluated appropriately Similarly there is no clinical distinction between two patients with T scores of 2 49 and 2 51 if they have the same age and have no other risk factors Other risk factors besides T score and age include previous fractures frame size smoking etc See the Physician Learning Series include
102. ults to Walker Walker Sonix results R 0 93 An relative risk of 1 84 for hip Sonix UBA 575 fracture was estimated for Sahara based on published Walker Sonix data 1 4 SAHARA Clinical Bone Sonometer Introduction 1 8 Individualization of Treatment The Sahara Clinical Bone Sonometer estimates the Bone Mineral Density BMD of the heel BMD results are used by the physician to assess skeletal status in the evaluation of patients at risk for osteoporosis and other metabolic bone diseases and or patients who may have reduced bone density due to medical conditions indirectly affecting bone mineral metabolism medications prescribed for other conditions heritable or genetic factors lifestyle factors or other reasons Heel BMD results may be used by the physician along with other factors such as laboratory test results radiographs and family history in the diagnosis of osteoporosis and other conditions leading to reduced bone density When evaluating individual patients all relevant risk factors including Sahara results age previous fractures frame size smoking etc should be considered For additional information refer to the Physician Learning Series included with the Sahara system The frequency of use of this device to assess BMD is dependent on a number of factors including the precision of the device and the expected rate of loss or gain in BMD due to disease progression or therapeutic intervention and must be determin
103. upplied in the Accessories Kit to clean the phantom and transducer pads and dry wipes to dry them 11 If the QC test is within limits the display screen will display 3 8 SAHARA Clinical Bone Sonometer 12 12 13 Quality Control QC Passed Press On To obtain the results press the button The Control Panel Screen displays QAB x QAS y The QC results are reported in terms of QAB and QAS which are unitless parameters defined as follows 3 QAB is calculated by dividing the measured BUA by the actual phantom BUA value that was entered at the factory and also appears on the phantom QAS is calculated by dividing the measured SOS by the actual phantom SOS value that was entered at the factory and also appears on the phantom If desired pressing the button again will display the absolute BUA and SOS values The Control Panel Screen displays BUA x SOS y A printout of the QC results may be obtained by pressing the PRINT FEED button on the control panel Clinical User s Guide 3 9 3 Quality Control Figure 3 12 Press PRINT Print Open Feed Prep as Jr 9u o pc esses sanar CLINKCAL GONE SORCMETER 14 If the QC is outside of normal limits then the screen will display Repeat QC in 1 hour Continue Press ON In most cases the cause of the REPEAT message is not a system malfunction but is
104. utton is used to inform the Sahara that program information such as setting time and date will follow This button is used to initiate functions entered with the PROGRAM and Numeric Keypad This button allows the user to toggle between Estimated BMD results and QUI BUA SOS results after a measurement It is also used in the PROGRAM mode to alter numeric sign and select choices Introduction 1 Specifications IEC 601 1 Class 1 Type BF IPXO The UL classification for the Sahara Clinical Bone Sonometer is Class 1 Equipment Table 1 2 lists the specifications for the Sahara clinical system Table 1 2 Measurement Site Calcaneus heel Sahara Specifications _Coupling Method Sahara Coupling Gel only Measurement Time less than 10 seconds Patient Reports Built in Strip Printer Measurement Results Estimated Heel BMD and Quantitative Ultrasound Index QUT obtained from measured BUA and SOS Estimated Heel BMD C V 3 Absolute Precision 0 014 g cm QUI C V 2 6 Absolute Precision 2 2 SOS C V 0 22 Absolute Precision 3 4 m s BUA C V 3 7 Absolute Precision 2 6 dB MHz QC Check Daily utilizing supplied QC phantom Operating temperature range 60 100 F 15 37 7 C Operating humidity range 20 80 R H non condensing Shipping and Storage Ambient Temperature 0 to 120 F 17 8 C to 49 C Relative Humidity 20 to 95 Atmospheric Pressure 500 hPa to 1060 hPa Power Requirements 100 240 VAC 50 60 Hz lt
105. ve performance of the system Processor 80486 Co Processor recommended but not required CPU Speed 33 Mhz RAM 8 MB Display 640 by 480 by 16 greyscale Hard Disk 100 MB Floppy 3 5 1 44 MB Serial port COM STD 16550 UART or equivalent high speed Parallel port Printer Centronics standard Windows Version 3 1 or Win95 Safety Rating IEC 950 or equivalent Advanced Clinical User s Guide 1 17 1 Introduction There are no controller boards to add to the computer All communication between the Sahara and the computer takes place over a standard serial port and cable RS232 connection One end of the cable plugs into the Sahara serial port connector and the other end plugs into the computer s COMI or COM2 serial port connector The serial cable is provided with the Advanced Clinical Software This communication cable Hologic PN 180 0318 is an industry standard PC to PC null modem cable with 9 pin D female connectors on each end For older computers with only a 25 pin D connector adapters are readily available wherever computers are sold The Advanced Clinical Software is supplied on 3 5 inch disks along with an automatic installation program Quality Control QC Phantom The QC phantom supplied with the Sahara system serves two distinct purposes 1 Daily measurements of SOS and BUA using this phantom allows monitoring of system performance over time See the Quality Control chapter in this manual for more in
Download Pdf Manuals
Related Search
Related Contents
BasicPlus2 WT-D & WT-P Thermostats d`ambiance mode-d-emploi-PSU-12 Sony CPD-17F03 User's Manual Funciones WO81 LB 724 manual.qxd CALDAIA A PELLET TouchNavigator Corel PHOTO-PAINT 12 et ses nouveaux outils Copyright © All rights reserved.
Failed to retrieve file