Home
Automatic Toilet Seat User Manual
Contents
1. Automatic Toilet Seat User Manual Thank you for ordering the Sensor Toilet Seat Through daily use you will discover it s many benefits Included Parts Fig 1 e 2x Metal screws O e 2x Rectangular washers O e 2x Adjustment brackets e 2x Large fastener try to use these first O e 2x Large plastic bolt cap use these with the large fastener O e 2x Small plastic bolt cap not shown use these with the small fastener e 2x Small fastener not shown use these only if the large fastener doesn t fit e 2x Hexagonal metal bolt e 1x Rechargeable battery e 1x A C Adapter charger e 1x User manual e 1x Sensor toilet seat with attached mounting bracket you will need 1x Phillips head screwdriver Metal Screw Adjustment Een Rectangular Warning do not sit on lid cover Washer f Metal Scraw PN Adjustment EL Rectangular 35 Washer E x Eng E a gms A a o al F a sE a E y amp a 7 Adjustment Adjustment Teeth jjustme 3 _ E Teeth coy e Plastic Bolt Cap 4 4 tener Hexagonal dci T Metal Bolt Plastic Bolt Cap Hexagonal Metal Bolt 2 www fw3group com tel 01404 814292 Automatic Toilet Seat User Manual Quick Installation Guide 5 Place adjustment brackets onto the mounting bracket 1 Remove your old toilet seat from your toilet bowl l 6 Put the rectangular metal washer onto the adjustment 2 Push a
2. ically increase or reduce the sensor range Lower the range enough so the infrared beam does not mistake bath room fixtures for an occupant and fails to close and high enough so the infrared sensor detects the occu pant during use and does not close unintentionally 2 When the cover is opened put the hand within the range of the top sensor to lift the seat automatically 3 When the seat is opened put the hand within the range of the top sensor to put the seat down 1 Turn the dial all he way to the left to turn off the sen sor toilet seat 2 Turn the dial to the right to hear and feel a click to turn on the sensor toilet seat Immediately after the dial has passed the click it is set to the shortest sensor range 18 inches 3 To increase the sensor range gradually turn the dial to the right If the cover or seat remains open for several minutes even without an occupant or movement in the sensor range the sensor range is set too high for your room size you should reduce the sensor range by turn ing the dial to the left 4 Both seat and cover will close automatically after the occupant and motion sensors no longer detect an occu pant or movement the blue LED light will stop blinking for 30 seconds 5 If only the cover is opened it will automatically close after both sensors no longer detect an occupant or movement for 15 seconds 6 To open or close the seat put your hand within the range of the top
3. nd hold grey button on the side of the Sensor Prackets Toilet Seat Release and slide off Mounting Bracket from the Sensor Toilet Seat Fig 1 7 Put the hexagonal metal bolts onto the plastic bolt caps Fig 4 3 Check if the large fasteners can fit into the screw 8 Put the plastic bolt caps onto the fastener Fig 5 holes of your existing toilet bowl Fig 2 If it is too big to fit the holes use the smaller fasteners Fig 5 Fig 2 9 Insert screw through the rectangular metal washer adjustment brackets and through the hole in the toilet 4 Place and align the mounting bracket on to your toilet bowl Fig 6 bowl Fig 3 www fw3group com tel 01404 814292 3 Automatic Toilet Seat User Manual After installation the sensor toilet seat should be aligned 10 Insert and turn the screw into the fastener and the to the toilet bowl Fig 10 plastic bolt cap as you hold them from below Fig 7 The fastener bottom will open up as you tighten the screw Fig 8 Leave this screw loose until step 12 Removing the toilet seat To remove the sensor toilet seat 1 Push and hold the grey release button 2 Slide out the Sensor Toilet Seat 11 Repeat the steps 7 and 8 for the other side 12 Align the mounting bracket and tighten the screws 13 Push and hold the grey button while sliding the sen sor toilet seat onto the bracket Fig 9 Fig 11 14 Inset battery into the battery chamber 4 w
4. r in the hole on the bat tery and charge it in any electric outlet www fw3group com tel 01404 814292
5. sensor at least 2 seconds after the previous activation The seat will open or close depend ing on it s current state 6 www fw3group com tel 01404 814292 Automatic Toilet Seat User Manual Charging the Battery When the sensor toilet seat is working abnormally or the opening speed of the cover and seat is slower then nor mal the battery may need to be charged The recharge able battery is located in the battery compartment on the top of the back of the toilet seat To charge If you have an electric output near the toilet seat you can charge the battery while it is in the battery com partment without turning off the power Simply plug the charger into the A C plug in hole located next to the sensor dial 4 The LED light on the A C adaptor will turn from RED The LED light on the A C adaptor will turn from RED to to GREEN when the battery is fully charged GREEN when the battery is fully charged 5 Once fully charged re insert the battery and make sure it is secured in the battery compartment For best performance Charge battery for 24 hours be fore in initial use Charge battery for 8 hours for normal recharge If you do not have an electric power output near the toilet seat 1 Turn off the sensor toilet seat by turning the dial all the way to the left until a click is heard and felt 2 Push the grey release button to eject the battery from the compartment 3 Plug in the A C power adapto
6. ww fw3group com tel 01404 814292 Automatic Toilet Seat User Manual Specifications Sensor Ranges e Front sensor when cover is closed 10 to 15 cm e Top sensor when cover is opened 5 to 10 cm e Occupant sensor in the centre of the cover adjustable 45 to 100 cm e Occupant motion sensor in the centre of the cover fixed 120 detection angle e Note second occupant motion sensor 120 horizontally and vertically Sensor positions e Front sensor 45 angle upward e Top sensor points straight up e Occupant sensor points horizontally e Motion sensor 120 horizontally Front Sensor Occupant Sensors note second occupant motion sensor 120 degree horizontally and vertically Note the sensors are the latest beam type infrared sensor Simply break the beam as you approach it will acti vate quickly DO NOT wave at the sensors as they will not activate in order to prevent unintentional opening Touchless Toilet Seat Top Sensor Cover C Front Occupant Sensor ded Range Dial Sensor N A Occupant Occupant Motion Rechargeable Sensor i iy Battery y Battery Release SUNON A 2 A c Plug in Jack www fw3group com tel 01404 814292 5 Automatic Toilet Seat User Manual Occupant Sensor Range Quick Starter Guide Adjustment 1 Approach within the range of the front sensor the Use the dial on the side of the sensor toilet seat to cover will open automat
Download Pdf Manuals
Related Search
Related Contents
LS17 Stereo Preamplifier Wartungsheft / Service Manual/ Carnet d'entretien F D Curtis RCD163A User's Manual Rane SSE-35 Home Equalizer Motivierte Aufmerksamkeit und Atmung - ETH E Guía del usuario de TalkSwitch v6.50 Instrucciones de Instalación. Registrador de temperatura CAMRegis Copyright © All rights reserved.
Failed to retrieve file