Home

eZ80190 Development Kit Quick Start Guide - Digi-Key

image

Contents

1. eZ80 User Manual UM0123 for details regarding the development of eZ80 software within the ZDSII environment Also see the user manual contained in this kit to review hardware operation in detail Additional Topics Table 2 lists documentation relevant to additional embedded projects Some Technical Notes reference source code that can be downloaded from the ZiLOG website If you are experiencing problems with the Rebuild All or Build commands ensure that there is sufficient memory on the host See the System Requirements on page 1 Additional Topics QS0004 13 0606 eZ80190 Development Kit Quick Start Guide ZiLOG Page 13 Table 2 Additional Development Support Documentation Using the ZDSII Integrated Flash Loader Utility TN0012 gt Note For programming guidance please consult the ZiLOG TCP IP Software Suite Reference Manual RM0008 available on the eZ80 Software and Docu mentation CD ROM and upon registration from the software page on the ZiLOG website Online Software Updates It is important to register your new eZ80190 Development Kit in order to receive timely notification of available software updates ZiLOG will post future software updates on zilog com for registered customers As anonregistered customer you can still browse the software on zilog com but you will not be able to download certain software components Related Documents The documents listed in Table 3 apply to the eZ80190 micropro
2. 192 168 1 21 255 255 255 0 should The Universal Power Supplies included in this kit contain three plug adapters each to accommodate dif fering international power requirements To configure the proper adapter please refer to the eZ80190 De velopment Kit User Manual UM0141 Configure the Hardware QS000413 0606 eZ80190 Development Kit Quick Start Guide ZiLOG Page 5 work for your PC The subnet portion of the IP address 192 168 1 should be the same on the ZPAKII unit and the PC The host portion of the IP address the fourth octet should be different 50 and 21 Alternatively the IP address subnet mask of the ZPAK II can be modified to match the PC s existing network setup Changing the PC s Settings to Match ZPAKII After completing the following steps to change the PC s Ethernet settings proceed to the Running Sample Projects section on page 11 gt Note The instructions that follow were developed for the MS Windows XP plat form If your Windows operating system is different please refer to your MS Windows OS manual for details 1 Open the Windows Control Panel and double click the Network and Internet Con nections icon The Network Connections dialog box appears as shown in Figure 3 S Network Connections DER File Edit View Favorites Tools Advanced Help Q ax Q x pO Search Folders E Address e Network Connections _ LAN or High Speed Internet Network Tasks ocal Area Co
3. Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks gt C Show icon in notification area when connected Figure 5 The Local Area Connection Properties Dialog QS000413 0606 Configure the Hardware eZ80190 Development Kit Quick Start Guide Page 8 ZiLOG 4 Inthe panel labeled This connection uses the following items select the Internet Protocol TCP IP item to highlight it and click the Properties button see Figure 5 for an example The Internet Protocol TCP IP Properties dialog box appears as shown in Figure 6 Internet Protocol TCP IP Properties Genera You can get IP settings assigned automatically if your network suppots this capability Otherwise you need to ask your network administretor for the appropriate IP settings Qbtain an IP address automatically Use the following IP address IP address Subnet mask Default gateway Use the following DNS server addresses Prefered DNS server Altemate DNS server a Advanced Cancel Figure 6 The Internet Protocol Properties Dialog 5 Enter values for the IP address and subnet mask to match those shown in Figure 4 Leave any remaining fields blank In this example an IP address of 192 168 1 21 and a subnet mask of 255 255 255 0 are being assigned to the PC These values place the PC on the same network as the ZPAK II unit and do not c
4. Inthe example output above y y y denotes the current version of the TCP IP stack software and x x denotes the current version of ZPAK II The console prompt is not case sensitive 7 Atthe ZPAKII prompt enter H and press ENTER The following message should appear ZPAKII gt H display this Help change ipAddress change ipSubnet mask change ipGateway change Portnumber change dtli Variable count change dtli Buffer size load deFault settings display Current settings toggle pAssword toggle Dhcp option change passWord Reset zpakii DSE0UrawwaguvunnyysA Configure the Hardware QS000413 0606 eZ80190 Development Kit Quick Start Guide ZiLOG Page 11 ZPAKII gt 8 Use the I command to change the ZPAKII s IP address to one that is compatible with the PC Use caution to avoid creating a conflicting IP address 9 Use the s command to change the ZPAKII s subnet mask to one that is compatible with the PC Typically the subnet mask is the same as that of the PC gt Note All changes are saved to Flash memory inside the ZPAKII 10 Cycle the power on the ZPAKII for the new settings to take effect The hardware is now configured and ready for application development with the eZ80190 device Running Sample Projects After installing the ZDSII software and setting up the hardware the user can download sample software projects for the eZ80190 Development Kit and review them on the eZ80 Development Pla
5. 2 for guidance Ethernet Hub 9 VDC eZ80 lt lt Development ZPAK II Platform Figure 1 Hardware Setup using an Ethernet Hub Development PC RJ 45 E NET Module RS 232 Development PC bac enon Platform Crossover CAT5 E NET ZPAK II Figure 2 Hardware Setup using a Crossover Ethernet Cable not supplied in the kit 1 Yoy that the eZ80190 Module is properly seated on connectors JP1 and er of the eZ80 Development Platform To mount the eZ80190 Module onto the eZ80 Devel opment Platform ensure that the pin numbering and alignment are correct by a ing pin 11 of JP1 JP2 on the eZ80190 Module to pin 1 of JP1 JP2 on the eZ80 Development Platform gt Note The eZ80190 Module features two 60 pin connectors Ensure the RJ45 connector on the module is hanging over the edge of the eZ80 Development QS000413 0606 Install the Hardware eZ80190 Development Kit Quick Start Guide 5 Page 4 ZiLOG Platform and that module jumpers JP1 and JP2 are aligned with their recepta cles on the platform JP1 JP2 pin 60 on the module fits into pin 50 of the receptacle on the eZ80 Development Platform Pins 1 10 on the module are not connected to the eZ80 Development Platform Connect the 9 VDC power supply to the eZ80 Development Platform Connect the ZDI Target Interface Module TIM the small PCB to ZPAKII by using the keyed 40 conductor ribbon cable Connect the TIM to the ZDI port on the eZ
6. 80 Development Platform Because the 6 pin TIM connector is not keyed take care to align the TIM with the 6 pin ZDI port as follows a The Altera chip must face upward and the yellow Z logo must face downward b Align pin of the TIM module to pin 1 of the blue ZDI socket J4 Connect a straight Ethernet cable from a free port on the Ethernet hub to the Ethernet port on the ZPAK II unit Repeat this procedure to connect the development PC s Ethernet port to the same hub In any case do not connect the PC or ZPAKII to the Uplink port Port 4 of the Ethernet hub Connect a 7 5 VDC power supply to the hub For other issues pertaining to the hub please refer to the documentation for the hub supplied with this kit Note Ifa hub is not used connect a crossover Ethernet cable not supplied in the kit from the PC to the ZPAKII unit See Figure 2 for reference To anticipate possible modifications to ZPAK II s Ethernet IP address connect the serial port on the PC to the console port on the ZPAKII via the supplied serial cable and the 10 pin adapter cable Connect the 5VDC power supply to the ZPAKII unit Configure the Hardware The default IP address and subnet mask of the ZPAK II debugger are 192 168 1 50 and 255 255 255 0 respectively For the development PC running ZDS II to communicate with the ZPAKII unit the PC s Ethernet adapter should be configured for the same subnet as ZPAKII For example an IP address subnet mask of
7. Windows 98SE WinNT 4 0 SP6 Win2000 SP3 WinXP SP 1 Pentium III 500 MHz processor Pentium II 233MHz processor 128MB RAM 96MB RAM ZiLOG Worldwide Headquarters 532 Race Street San Jose CA 95126 Telephone 408 558 8500 Fax 408 558 8300 www zilog com eZ80190 Development Kit Quick Start Guide Page 2 ZiLOG Table 1 ZDS II System Requirements Continued Recommended Configuration Minimum Configuration 65MB hard disk space 25MB hard disk space Super VGA video adapter Super VGA video adapter CD ROM drive CD ROM drive Ethernet port Ethernet port One or more RS 232 communications ports One or more RS 232 communications ports Internet browser Internet Explorer or Internet browser Internet Explorer or Netscape Netscape Note Excluding documentation Install the Software Follow these steps to install ZDSII with the eZ80 ANSI C Compiler 1 Insert the ZDSII CD into your computer s CD ROM drive The CD launches the DemoShield application automatically Note The DemoShield application automatically launches each time the CD ROM is inserted into the drive However the DemoShield installer may not launch automatically on some Windows 2000 systems If this issue should occur please navigate your browser to the following Microsoft support page for assistance http support microsoft com default aspx scid KB en us g155217 ZiLOG recommends registering your new ZDSII software Registe
8. cessor Table 3 eZ80190 Documentation eZ80190 Development Kit Quick Start Guide QS0004 eZ80190 Development Kit User Manual UM0141 eZ80190 Product Specification PSO066 eZ80190 Product Brief PB0052 eZ80190 Module Product Specification PS0191 eZ80190 Module Product Brief PB0106 External Flash Loader Product User Guide PUG0012 Errata to eZ80190 Device UP0019 QS000413 0606 Online Software Updates eZ80190 Development Kit Quick Start Guide Page 14 ZiLOG In addition to the documents listed in Table 3 the documents listed in Table 4 apply to the entire family of eZ80 devices Table 4 eZ80 Family Documentation eZ80 CPU User Manual UM0077 ZiLOG TCP IP Software Suite Reference Manual RM0008 ZiLOG Developer Studio II eZ80 User Manual UM0123 eZ80 Connectivity PPP Operation Application Note ANO109 Thermostat Demonstration Product User Guide PUG0014 ZPAKII Product User Guide PUG0015 This publication is subject to replacement by a later edition To determine whether a later edition exists or to request copies of publications contact ZiLOG Worldwide Headquarters 532 Race Street San Jose CA 95126 Telephone 408 558 8500 Fax 408 558 8300 www ZiLOG com Document Disclaimer ZiLOG is a registered trademark of ZiLOG Inc in the United States and in other countries All other products and or service names mentioned herein may be trademarks of the compani
9. eZ80190 Development Kit Quick Start Guide ZiLOG QS000413 0606 Introduction Follow this guide to install and begin using your new eZ80190 Development Kit from ZiLOG The setup procedure guides the user through e Software installation and online registration e Hardware installation and configuration e Running sample projects on the eZ80 Development Platform e Obtaining software updates via zilog com With this eZ80190 Development Kit you can build and run the LedDemo pro demonstra tion project described in this document Also available is the target based external Flash Loader utility installed on the eZ80190 Module which allows the user to erase and repro gram Flash memory inside an eZ80 processor This utility is primarily designed for field upgrades on stand alone target systems For more information about the Flash Loader util ity please see the External Flash Loader Product User Guide for the eZ80190 device PUGO0012 Kit Contents The eZ80190 Development Kit contains an eZ80 Development Platform an eZ80190 Module a power supply the ZPAK II Debug Interface Tool and documentation on CD ROM For a product specific listing of items in the kit please see the Kit Contents sheet found inside this kit System Requirements Table 1 lists the PC requirements for running ZDSII Table 1 ZDSII System Requirements Recommended Configuration Minimum Configuration PC running MS Windows XP SP1 PC running MS
10. ect the LedDemo pro project within the above filepath and click Open A list of source files appears in the Workspace panel 3 From the Project menu in ZDS select Settings 4 The Settings dialog box appears In the Settings window select the Debugger tab In the Debugger tab click on the Configure ZPAKII button 5 The Configure ZPAKII dialog box appears In the IP Address field a default IP address 192 168 1 50 is displayed and highlighted This IP address tells ZDSII where to find ZPAKII on a network Enter an IP address of 192 168 1 50 If this address already appears in the IP Address field it must be reentered If another IP address for ZPAKII is more compatible with your network settings enter that IP address Do not change the other parameters Click OK to return to the Settings dia log box Click Rebuild All Click OK to close the Settings dialog box 6 Push the button labeled RESET on the eZ80 Development Platform 7 When the build is complete download the LED I O demo into the eZ80 Develop ment Platform by selecting Build gt Debug Reset 8 When the demo is downloaded explore the debug toolbar for the various debugger features To run the application select Build gt Debug Go 9 When the demo software is running the dot matrix LED display on the eZ80 Devel opment Platform should be illuminated and stepping through a number of display pat terns Please refer to the ZiLOG Developer Studio
11. es with which they are associated 2006 by ZiLOG Inc All rights reserved Information in this publication concerning the devices applications or technology described is intended to suggest possible uses and may be superseded ZiLOG INC DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION DEVICES OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT ZiLOG ALSO DOES NOT ASSUME LIABILITY FOR INTELLECTUAL PROP ERTY INFRINGEMENT RELATED IN ANY MANNER TO USE OF INFORMATION DEVICES OR TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE Devices sold by ZiLOG Inc are covered by warranty and limitation of liability provisions appearing in the ZiLOG Inc Terms and Conditions of Sale ZiLOG Inc makes no warranty of merchantability or fitness for any purpose Except with the express written approval of ZiLOG use of information devices or technology as critical components of life support systems is not authorized No licenses are con veyed implicitly or otherwise by this document under any intellectual property rights Related Documents QS000413 0606
12. nnection E Create a new nabled connection L a GVC REALTEK Ethernet 10 10 view status of this connection Change settings of this connection Other Places G Control Panel My Network Places 3 My Documents i My Computer Details Figure 3 The Network Dialog QS000413 0606 Configure the Hardware eZ80190 Development Kit Quick Start Guide M A d Page 6 ZiLOG 2 Inthe panel labeled LAN or High Speed Internet double click the Local Area Connection icon The Local Area Connection Status dialog box appears as shown in Figure 4 4 Local Area Connection Status General Support Connection Status Connected Duration 3 days 05 55 51 Speed 100 0 Mbps Activity Sent AN Received Packets 44 566 35 712 Properties Close Figure 4 The Local Area Connection Status Dialog Configure the Hardware QS000413 0606 eZ80190 Development Kit Quick Start Guide Page 7 ZiLOG 3 Inthe Local Area Connection Status dialog box click the Properties button The Local Area Connection Properties dialog box appears as shown in Figure 5 t Local Area Connection Properties General Authentication Advanced Connect using E Intel R PRO 100 VE Network Connection This connection uses the following tems E amp File and Printer Sharing for Microsoft Networks v Sas Packet Scheduler Intemet Protocol TCP IP Install s Description Transmission Control Protocol
13. onflict with the IP address of ZPAKII 6 Click OK and restart the PC 7 The PC is now ready to communicate with ZPAKII via the ZDSII software Configure the Hardware QS000413 0606 eZ80190 Development Kit Quick Start Guide ZiLOG Page 9 8 The default IP address of the ZPAKII unit is 192 168 1 50 If this address conflicts with another address on the LAN or if another address is more compatible proceed to the next section otherwise proceed to the Running Sample Projects section on page 11 Changing ZPAKII Settings to Match the PC There are two ways to change the ZPAK II s default settings One method is via the ZPAK II embedded web page via a browser over an Ethernet connection The other way is via the ZPAKII console port The following steps describe the console port method 1 The serial port of the PC should already be connected to the console serial port of the ZPAK II unit 2 Launch HyperTerminal on the PC by navigating from the Start menu to Programs Accessories HyperTerminal or Accessories Communications gt Hyper Terminal depending upon your Windows OS 3 Create a new connection in HyperTerminal by selecting the appropriate COM port in the Connect using field of the Connect To dialog Click OK gt Note This connection is a direct connection via a COM port not a modem 4 Ifyou select COM1 the COM1 Properties dialog appears Enter the following port settings and click OK Bit
14. ring ZDSII is quick and easy Please see the online registration page on the ZiLOG website and enter the requested information Note Certain software components from ZiLOG can only be obtained upon online registration ZiLOG will notify registered customers when software updates become available ZiLOG also offers free technical support to our registered customers In general please visit the ZiLOG website for the latest informa tion regarding software and other product updates The user can install a number of files when running the DemoShield application by clicking the Install Products button in the main menu and installing ZDSII and or the entire documentation set However the user can also choose to manually copy the Install the Software QS0004 13 0606 eZ80190 Development Kit Quick Start Guide ZiLOG Page 3 Documentation directory from the CD ROM by clicking the Browse CD button pre sented in the main menu and copying this directory to the user s hard drive gt Note The target resident Flash Loader utility is updated regularly Please see the Software Tools page on the ZiLOG website for the latest version Install the Hardware The ZPAK II Debug Interface Module features an Ethernet interface and an RS 232 con sole port Slight modifications to the network pone may be required for first time use Follow the steps in this section to install the eZ80 Development Platform and the ZPAKII debugger Refer to Figures and
15. s per second 57600 Data bits 8 Parity None Stop bits 2 Flow control None 5 Ensure that the connection is in the Connected state by observing the HyperTerminal status bar If not connected select Connect from the Call menu 6 While holding down the z key lowercase on the PC s keyboard press the RESET button on the side of the ZPAKII Releasing the z key displays a ZPAKII console boot up message in HyperTerminal followed by the ZPAK prompt as shown below gt Note To locate the Reset button view the ZPAKII debug interface tool with the XTools logo reading top side up The Reset button is recessed within the 2 To change the ZPAK II settings from their defaults via a web browser please consult the ZPAKII Debug Interface Tool Product User Guide PUG0015 QS000413 0606 Configure the Hardware eZ80190 Development Kit Quick Start Guide Page 10 ZiLOG side of the unit facing you Use a toothpick paper clip or similar narrow object to press the Reset button ZiLOG TCP IP Software Suite v1 1 Copyright C 2003 ZiLOG Inc All Rights Reserved clock enabled created buffer Pool 1524 32 created buffer Pool 4096 8 IP Address 192 168 1 50 IP Subnet 192 168 1 0 255 255 255 0 IP Gateway 192 168 1 254 netstart exiting stack extent 379 2048 PAKII version x x opyright 2001 2002 ZiLOG Inc ll Rights Reserved PAKII Console version 1 5 NPaQN Type H for help PAKII gt N gt Note
16. tform These sample projects are included in the ZDSII sample directo ries which are located in their respective filepaths as shown c Program Files ZiLOG ZDSII_eZ80_ lt version gt Samples lt processor family gt lt processor type gt _LedDemo srec where lt processor family gt represents the eZ80 product line and lt processor type gt represents the eZ80190 device that powers the development module contained in your kit gt Note Please refer to the ZiLOG Developer Re eet User Manual UM0123 for details regarding the development of eZ80 software within the ZDSII envi ronment Also see the user manual and product specifications pertinent to the device and module contained in this kit to review hardware operation in detail Running the SRAM LED Demo Project Using ZDSII the user downloads the LedDemo pro file to internal SRAM Follow the steps below to build and run the demo 1 Launch ZDSII by navigating from the Start menu to Programs gt ZiLOG ZDS eZ80_ lt Version gt gt ZDSII eZ80_ lt version gt From the File menu in ZDSII choose Open Project and navigate to the following filepath QS000413 0606 Running Sample Projects eZ80190 Development Kit Quick Start Guide c Program Files ZiLOG ZDSII_eZ80_ lt version gt Samples lt processor family gt lt processor type gt _LedDemo sre where lt Processor Type gt represents the eZ80190 device that powers the develop ment module contained in your kit 2 Sel

Download Pdf Manuals