Gst-Def 3.0 Defining Software
Contents
1. 12 5 3 4 Define Repeater Panels 15 5 3 5 Define Equations 16 5 3 6 Customize Device Type 20 5 3 7 Upload Running Record 21 5 4 Data Protection 22 5 5 Loop Paste and Copy 24 6 Caution 24 GstDef3 0 Defining Tool User s Manual Page 1 1 Overview The newly developed GST Intelligent Fire Alarm System Defining Tool software is used for system commissioning It is designed with friendly user interface and powerful functions The fire alarm control panel FACP that can use this software include GST200 series GST200 and GST200 2 GST5000 series GST5000 GST5000W and GST5000F and GST IFP8 FACPs The main features of this highly intelligent package are By dividing control panels into logical zones and with descriptions of each zone the control fun
2. 4 5 1 4 Database 5 5 1 5 Device type 5 5 1 6 Cancel 5 5 1 7 About 6 5 1 8 Exit system 6 5 2 General Operation 6 5 2 1 Panel Operation 6 5 2 2 Zone Operation 7 5 3 System Definition 7 5 3 1 Define zones 7 5 3 2 Define devices 9 5 3 3 Define Control Keys
3. GstDef3 0 Defining Tool User s Manual CONTENTS 1 Overview 1 2 System Requirement 1 2 1 Hardware 1 2 2 Software 1 3 Installation 1 4 Download Card 2 5 User s Guide 3 5 1 Function Tools 3 5 1 1 Com Set 4 5 1 2 Setting Language 4 5 1 3 Com Test
4. Any copy or modification without the permission of the manufacturer is prohibited This operation manual may be updated according to product upgrading without notification Gulf Security Technology Co Ltd No 80 Changjiang East Road QETDZ Qinhuangdao Hebei P R China 066004 Tel 86 0 335 8502434 Fax 86 0 335 8502532 service gst fs utc com www gst com cn 30309193
5. Gas equation The gas extinguishing control equation requires to first confirm if gas extinguishing is permitted on the FACP as shown in Fig 40 GstDef3 0 Defining Tool User s Manual Page 20 Fig 40 4 Edit equation Refer to 4 Edit equation in 5 3 5 2 Equations in GST200 5 3 5 4 Equations in GST IFP8 The definition and edition of equations for GST IFP8 is the same as GST5000 Please refer to the description for editing GST5000 equations 5 3 6 Customize Device Type Fig 41 Choose the node of the tree structure at the left of the main screen and click lt Device Type gt button the screen in Fig 41 will pop up For GST200 2 and GST IFP8 the name of device type is user definable Function of tool bar buttons are as follows lt Import gt Importing ini file with saved device type lt Save gt Saving the current device type into current database so that the device type doesn t change when running the software next time lt Save As gt Saving the current device type as an ini file lt Down gt Downloading the selected device type to the FACP lt DownAll gt Downloading all currently defined device types to the FACP GstDef3 0 Defining Tool User s Manual Page 21 lt UpLoad gt Uploading device type to the computer lt UpLoadAll gt Uploading all device types to the computer lt Default gt Restoring the default device type lt Cancel gt Canceling the current operation lt Quit gt Closing th
6. 0 Backup as shown in Fig 7 Fig 7 5 1 5 Device type Add device types and look at the related symbol as shown in Fig 8 Fig 8 5 1 6 Cancel Cancel current operation It is used to stop downloading or uploading communications GstDef3 0 Defining Tool User s Manual Page 6 5 1 7 About About the copyright 5 1 8 Exit system 5 2 General Operation The system map provides a quick method to define FACPs loops devices manual keys and zones and etc as shown in Fig 9 Fig 9 5 2 1 Panel Operation 5 2 1 1 Add New FACP Right click on lt FACP gt click on lt Add FACP gt The dialogue box is shown in Fig 10 Fig 10 FACP Name Any description of the FACP which can be blank FACP Address The FACP Address must be unique for each control panel FACP Type The FACP Type must be correct otherwise GstDef Tools cannot communicate with the panel This setting cannot be changed once it is saved Net If lt Net gt is selected the devices in this panel can be used into equations on other panels Start Zone The Start Zone is for network use only for GST200 When the panel is connected to network the information will be displayed on main panel as lt Zone Local zone Start Zone gt The setting can be modified later 5 2 1 2 Delete FACP Right click the name of the panel select lt Delete FACP gt all configurations with this panel will be completely deleted GstDe
7. Same as for zones the upload or download can be done to one or a group of or all the devices in the current loop 5 3 2 5 Device Check Click on button the software will check the definitions of the current panel As mentioned in lt Device Number gt in the whole system the device number cannot be duplicated This operation will check all devices and give out the information If there are the same addresses from different loops installed into the same zone the duplicated condition may occur In this case please manually modify the 4th to 6th digits of lt device Number gt 5 3 2 6 Reload This operation will restore the definition from last lt Save gt operation All modifications not saved will be lost 5 3 3 Define Control Keys 5 3 3 1 General The panels except for GST IFP8 are configured with one or more Zone Indication and Manual Intervention Panels ZCP For GST200 and GST200 2 there are 32 buttons For GST5000 series the default configuration is 1 one ZCP which has 64 buttons The GstDef3 0 Defining Tool User s Manual Page 13 ZCP can be expandable on order The key indicators can be defined to one of the three types Zone Indication Start One Device or Silence A key indicator can only be set with one of the three types In GST5000 series the keys can be used for evacuation Zone Indication The indicators will show Fire Red lit Fault Yellow lit or Disable Yellow flash of the related zone Press
8. cted zone s 5 3 1 4 Save Press button to save all the modifications 5 3 1 5 Reload This operation will restore the definition from the last lt Save gt operation All modifications not saved will be lost 5 3 2 Define devices 5 3 2 1 General Fig 15 The items include lt Address gt The physical address of the device lt Device Number gt Each device has a 6 digit number normally arranged as zone number address This number must not be repeated in the whole system including network devices Although the zone number on GST5000 series can be manually modified it s recommended not modifying it to avoid any incorrect display lt Loop gt Showing the loop of the devices lt Zone gt Dropdown list to select zone lt Device Type gt Select device type by dropdown list For detectors or MCP this type should be selected according to the real device type For modules the type is decided by equipment connecting to the module For example there is a Fire Door connecting to a module addressed 17 so address 17 should be defined as 28 FireDoor To view the complete type list please refer to the appendix lt Properties gt Device properties which is only useful for output devices like sounder or output modules Refer to Fig 16 GstDef3 0 Defining Tool User s Manual Page 10 Fig 16 1 Level output means the output will be continuous until the device is stopped manually or the system is reset 0 Pulse output m
9. ctions of the panels are made clearer Providing the network definition of up to 32 FACPs of any model of GST200 and GST5000 series Communicating with FACP through RS232 interface at a rate of 2400bps Devices are distinguished with different icons Zones are easily distinguished with different colors Dropdown lists are used to save time Manual input is also available with memory ability from the software that makes it simpler for similar inputs Definitions can be edited in dialogue boxes C amp E equation definition with clear relationship easily selecting exact device or group devices by fuzzy logic In addition to normal text display the system also supports upload or download of bi direction text a mixture of left to right and right to left horizontal text for some special languages and the screen displays accordingly For GST200 2 and GST IFP8 name of device type is user definable and running record can be uploaded to computer and saved as an Excel file Supporting emerge of database loops of control panels can be pasted and copied Password protection for database For GST200 2 GST IFP8 control panels this tool can protect the customers data This software can be started using USB dongle which well protect the data Supporting multi languages The default language is English The language package can be downloaded from http www gst com cn eng
10. e current window Fig 42 Fig 43 The device type icon is also customer definable Right clicking the device type number in Fig 41 lt Define Images gt menu will pop up as in Fig 42 and Fig 43 and then clicking lt Browser gt can choose and save an icon 5 3 7 Upload Running Record Right clicking the FACP node at the left of the main screen as in Fig 44 a menu will pop up Choosing lt History Record gt the window as in Fig 45 will pop up GstDef3 0 Defining Tool User s Manual Page 22 Fig 44 Fig 45 For GST200 2 and GST IFP8 the user can upload the running record in the FACP to the computer by clicking lt Upload gt in the screen of Fig 45 After uploading clicking lt Export gt will save the current records in the form of an Excel file the user shall have the Excel program in the computer 5 4 Data Protection The software will check the USB dongle when it is started If there isn t USB dongle or invalid USB dongle connected the software can t be started GstDef3 0 Defining Tool User s Manual Page 23 The user should set a defaulted encryption password for local database when the software is running for the first time as shown in Fig 46 Fig 46 When users make a backup for the current database the software will indicate encryption Either use the default encryption password or a new password can be set When users restore database if the password in the database is same as t
11. e relationship between the devices should be manually set means OR logic X means AND logic The operation is the same for adding multiple devices to the result If the current panel is networked devices from other networked panels can be used in both conditions and results And actual zone numbers should not be bigger than 100 The delay time can be set individually to each output device The delay time is in second multiplied by 10 Maximum 10 minutes 600 seconds For example 6 means delaying 1 minute 6X10 60s Fig 34 After clicking the equation will be added to the list at the bottom Then add the next equation 2 Fuzzy Device For similar devices we can use Fuzzy Logic to save our work It means for these similar devices we use only one Fuzzy Device instead of inputting them one by one Tick lt Fuzzy Devices gt to start the function as shown in Fig 35 Fig 35 For example lt Zone gt 01 amp lt Dev Type gt 03 means any Optical detector in Zone 1 If lt Zone gt 02 lt Dev Type gt Any Type means any device in zone 2 Refer to Fig 36 Also the quantity can be set Between all these devices the logic is AND GstDef3 0 Defining Tool User s Manual Page 18 Fig 36 If lt Device QTY gt 2 means this condition is only getting true if any 2 of these devices alarm together 3 Rules for display Exact device Led by G Digit 2 amp 3 for zone number Dig
12. e screen and restart the panel Then press BROWSE button on the keypad If lt CRT INSTALLED gt appears it succeeds Otherwise check the card code and repeat the operation The code setting is shown as in Fig 2 GstDef3 0 Defining Tool User s Manual Page 3 Communication LED Communication LED Run LED Ones Digit 232 Communication Card To CRT Communication LED To Zone Indication and Manual Intervention Panel Run LED Fault LED Run LED Run LED 485 Communication Card Loop Card Main Board Tens Digit To Switch Board Fig 2 For GST IFP8 panel choose COMMUNICATION BOARD slot to insert the download card There is code set switch on the communication board Set the card code to next of the last card For example there are 2 loop cards in the panel which takes codes 01 amp 02 then the download card should be set as 03 Make the panel work in commission state the panel will show on right top corner of the screen and restart the panel Then enter lt USER SETUP gt lt 1 BROWSE gt lt 1 BROWSE DEVICES gt to ensure that CRT CARD is registered If unregistered check the card code and repeat the operation There is one more setting for download if all the panels are to be connected into network In this case there must be an individual address for each panel This address should match the address in the software For GST200 go to lt SYSTEM gt lt Network Setup gt lt Net Local Address
13. eans the output will only last for 10 seconds a pulse after started lt Location gt Detailed location of the device maximum 32 characters including letters numbers and some symbols lt Panel Loop gt lt Panel Number gt and lt Switch Key gt Definition to ZCP which will be described later For GST200 2 and GST IFP8 the uploaded device definition information also include if the device is successfully registered as shown in Fig 17 Fig 17 5 3 2 2 Special Definitions Loop capacity of GST200 is 242 devices including all types of addressable devices Loop capacity of GST200 2 is 484 devices including all types of addressable devices In each loop there are some addresses reserved for the system There are 5 addresses reserved in the 1st loop 238 Fault output Active when any fault occurs in the system 239 Loop monitor Active if the panel cannot detect testing voltage in Loop IN terminal of Loop 1 240 Sounder Circuit output Active when receiving any fire signal This terminal is designed for connecting with conventional alarm devices for general alarm purpose which can be stopped by silence key 241 F P E Fire Protection Equipment output Active on receiving any fire signal It is designed for connecting controlled equipment like AHU which cannot be stopped by silence switch 242 Fire alarm output Active on receiving any fire signal This terminal is designed for repeating fire signal remotely such as at the Civil Defen
14. f3 0 Defining Tool User s Manual Page 7 5 2 1 3 Export Devices Right click the name of the panel select lt Export Devices gt all the defined devices in this panel can be exported to a text file txt which can be easily converted to Excel file or other format 5 2 1 4 Export Equations This operation can export C amp E equations to a text file by double clicking 5 2 1 5 Upload and Download When a panel is selected the upload or download operation will cover all definitions relating to that panel including zones devices control switches and equations as shown in Fig 11 Fig 11 Upload means taking pre record information from the panel Download means sending the definitions to the panel 5 2 1 6 Save The Save operation is for completing definition Each time it will save all changes comparing with previously saved data 5 2 2 Zone Operation Clicking lt FACP Zone gt will go to zone operation Here you can add delete or modify the zones 5 3 System Definition 5 3 1 Define zones The protected area can be divided into several zones which in case of emergency situation in a zone a general location information can be shown on the FACP to give people the First Aid The zones should be divided according to building structure A major consideration is to make people easily access the area By BS standard each detection zone should be no more than 2000m2 to 3000 m2 for L1 or L2 The zone definitions are s
15. gt input the correct address Press Enter to confirm For GST5000 series go to lt SYSTEM gt lt Communication Setup gt lt CRT Setup gt input local address Press Enter to confirm For IFP8 panel go to lt SYSTEM SETUP gt lt 1 PROGRAMMING gt lt 3 COMMUNICATION SETUP gt lt 1 MONITOR INTERFACE gt input monitor interface loop number then input panel address Press Enter to confirm There are 2 LED indicators on the download cards The RED is showing communicating with panel main processor The GREEN is showing communicating with computer 5 User s Guide 5 1 Function Tools The toolbar is shown in Fig 3 clicking the corresponding button you can reach the relevant window Fig 3 GstDef3 0 Defining Tool User s Manual Page 4 5 1 1 Com Set Choose the serial port communicating with fire alarm control panel and recognize the existing serial port for setting as shown in Fig 4 Fig 4 5 1 2 Setting Language Define system language as shown in Fig 5 The software supports multi languages The default language is English The language package can be downloaded from http www gst com cn english products GST def html Fig 5 5 1 3 Com Test Test the communication as shown in Fig 6 Fig 6 GstDef3 0 Defining Tool User s Manual Page 5 5 1 4 Database Database tools for backup restoring and importing the database The default folder is Gst Software GstGMC 2
16. hared by all devices connected to the FACP Each zone may contain devices from different loops and devices from the same loop may be set to different zones Click lt FACP Zone gt and select a panel all zones defined in this panel will be displayed And click a zone number you can check all devices in that zone as shown in Fig 12 GstDef3 0 Defining Tool User s Manual Page 8 Fig 12 5 3 1 1 Add New Zone Click there will be a new zone shown at the bottom There can be maximum 30 zones for GST200 60 for GST200 2 255 zones for GST5000 series panels and 999 for GST IFP8 panel Description of the information will be shown on panel screen the name of the zone Maximum 8 characters 40 for GST IFP8 panel including letters number and some symbols lt ForeColor gt and lt BackColor gt When a device is defined into a zone the text lt ForeColor gt and background lt BackColor gt will easily spot it The default color is black on white as shown in Fig 13 Fig 13 Fig 14 GstDef3 0 Defining Tool User s Manual Page 9 As shown in Fig 14 GST IFP8 panel has additional lt Zone Mode gt lt Zone Sounder Mode gt lt Zone Resound Mode gt and lt Zone Led gt options 5 3 1 2 Delete zone Select a zone highlighted and click button 5 3 1 3 Download amp Upload By the operation will be done to all zones Select one or several zones and press the operation is done to the sele
17. he default encryption password the database will be opened directly If the password is different to the default encryption password the correct password should be input to open the database As for GST200 2 and GST IFP8 control panels users can enable or disable panel data protection mode by clicking Secure the FACP or Release the FACP as shown in Fig 47 and Fig 48 Fig 47 Fig 48 When the software tries to communicate with an Enabled panel any data operation including upload download batch upload batch download will verify information from the dongle and panel If the information matched the communication will be continued otherwise the operation will be terminated The communication between software and Disabled panel will not verify information between the dongle and panel For enabled GST IFP8 control panel it can be set to define manually or not Refer to Fig 48 GstDef3 0 Defining Tool User s Manual Page 24 5 5 Loop Copy and Paste Fig 49 The tool provides the loop paste and copy function For the similar loops it is easy to define in this way In Fig 49 right click the loop choose Copy Loop then select the loop need for definition click Paste Loop 6 Caution After completing all above definitions please make a backup of the database for future checking and modification The copyright of this software is reserved by the manufacturer and protected by law
18. ing loops there is one ZCP automatically added into Loop 1 shown as lt Control Switch 1 gt If more control switches are needed right click on the loop and click lt Add Control Switch gt Refer to Fig 25 GstDef3 0 Defining Tool User s Manual Page 14 Fig 25 The definition is done with the loop devices Normally the loop capacity will not be fully used Choose a group of unused addresses for defining the control switches as shown in Fig 26 Fig 26 1 Define Zone Indication Select the 64 Zone under lt device Type gt Set the addresses into individual zones Set a lt Switch Key gt number to each zone When a lt Switch Key gt is decided the lt Panel Loop gt and lt Panel Number gt will be automatically changed to 1 amp 1 That means this ZCP is the 1st one connecting to the 1st loop If the panel number and connected loop are different please modify them to the same manually 2 Define Start One Device Fig 27 Set the switches to be related with corresponding devices directly as shown in Fig 27 3 Define Silence Switch Select one unused address Set lt Device Type gt at 56 Silence and the wanted switch 4 Checking After saving the above definitions by clicking the lt Control Switch 1 gt on the left the complete definition list will be shown as in Fig 28 Fig 28 GstDef3 0 Defining Tool User s Manual Page 15 5 Upload and Download The definition will be down
19. ing the button can start all sounders in that zone This definition must be done to every zone Start One Device This option is only available for output devices The button will reverse the condition of the related device When it is started pressing this button will stop it This is optional that can be defined or not Silence This must be defined normally at the right bottom corner so that it is easy to reach Pressing this button will stop all started by fire signal sounders and the sounder output on the panel When the next fire signal comes the related sounders will be started again All Evacuation This function only available for GST5000 series Pressing the button will start all sounders and sounder outputs to evacuate the building manually The started sounders cannot be stopped by the SILENCE button They can only be stopped by RESET 5 3 3 2 Control Switches of GST200 and GST200 2 Fig 23 Fig 24 Choose the wanted zone or device address the related Function line will automatically change to Zone indication or Start One Device To define a silence button choose Silence in the Function Line as shown in Fig 23 and Fig 24 for GST200 2 with additional Loop column This definition is uploaded downloaded separately 5 3 3 3 Control Keys for GST5000 Series In GST5000 series panels the ZCP s is are connected to loop s By default it is connected to loop 1 To each loop Maximum 4 ZCPs can be connected When creat
20. it 4 to 6 for address Digit 7 amp 8 for device type For example G0207503 means an optical detector in zone 2 address at 075 Fuzzy device Led by S Digit 2 amp 3 for zone number means any zone Digit 4 to 6 for device quantity shown under lt Device QTY gt Digit 7 amp 8 for device type means any type of devices For example S0100203 means any two optical detectors in zone 1 The output can also be Fuzzy device The lt Device QTY gt 1 will start all devices complying with the setting 4 Edit equation An existing equation can be edited by clicking the lower part of Fig 34 5 3 5 3 Equations in GST5000 Series 1 Define a new equation The operations for adding a new equation is the similar to GST200 The only difference is if the current panel is in network devices from other networked panels can be used in both conditions and results as shown in Fig 37 The delay time is in second multiplied by 6 GstDef3 0 Defining Tool User s Manual Page 19 Fig 37 2 Fuzzy Device The Fuzzy Devices for GST5000 series is defined in a different way comparing with GST200 as shown in Fig 38 and Fig 39 Fig 38 Fig 39 It is using the 6 digit device number plus 2 digit device type code Any digit replaced by will represent any of the numbers from 0 to 9 For example 01 11 represents any MCP in zone 001 02 means any R amp F heat detector of the whole system 3
21. lish products GST def html 2 System Requirement 2 1 Hardware CPU Pentium IV 1 7G or above Free Hard disk 10GB or above Memory 512MB or above 2 2 Software Windows XP Professional Windows7 3 Installation The software setup file is named GstDef3 0_setup exe Double clicking the file and following the wizards will install the software into your computer GstDef3 0 Defining Tool User s Manual Page 2 To uninstall the software you can either go to lt Control Panel gt lt Add Remove Software gt or run the GstDef3 0_setup exe again 4 Download Card The software can work offline for defining in the office only connecting to the panel for downloading the definition The definition download needs an RS232 communication card P 9930 download card is for GST200 Connect the download card to the extend port on the main board with a ribbon cable Enter the commission password 24220011 and press the button SK1 on the main board as shown in Fig 1 Fig 1 If the RED LED on the download card flashes the download upload operation can be done Otherwise please repeat the above operation For GST5000 series panels choose any unused slot to insert the download card Set the card code to next of the last card For example there are 3 loop cards in the panel which takes codes 01 02 amp 03 then the download card should be set as 04 Make the panel work in commission state the panel will show Installer on top of th
22. loaded uploaded together with loop devices definition 5 3 4 Define Repeater Panels 5 3 4 1 Repeater Panel of GST200 and GST200 2 Fig 29 As shown in Fig 29 GST200 and GST200 2 can drive up to 10 repeater panels The description 8 characters can be downloaded to the fire alarm panel In case there is fault with the repeater panel the description will be displayed on the FACP But even if the repeater panel is not defined it will still work normally 5 3 4 2 Define Repeater Panel of GST5000 Series Select the FACP and add Loop 0 Loop 0 is defaulted as repeater panel loop as shown in Fig 30 Fig 30 After adding the loop the devices of repeater panel are shown in Fig 31 Its operation is the same as other device definition of GST5000 series GstDef3 0 Defining Tool User s Manual Page 16 Fig 31 5 3 5 Define Equations 5 3 5 1 General In case of fire the FACPs GST200 and GST5000 series will act according to the pre programmed equation There are TWO default actions that do not need to be defined 1 In case of fire in a zone the zonal sounders will be started immediately 2 In case of fire in a zone the panel outputs Sounder circuit output fire alarm output amp F P E will be started immediately Clicking lt Equations gt under lt FACP Net gt will get into equation definition as shown in Fig 32 and Fig 33 Fig 32 lt New gt Add a new equation lt Insert Dev gt Add a device in
23. se or Fire Brigade These definitions are fixed in GST200 from 236 to 242 that cannot be modified In GST5000 series the last 3 addresses can be modified to other types for different functions as shown in Fig 18 GstDef3 0 Defining Tool User s Manual Page 11 Fig 18 In multi loop panel GST5000 series Loop1 and other loops have only the last address 242 reserved which is defined as 57 Loop SW for monitoring the corresponding loop Refer to Fig 19 Fig 19 5 3 2 3 Loop Operation For GST200 there is only ONE loop When the panel is created the loop is configured as default For GST200 2 there are TWO loops When the panel is created two loops are configured as default For GST5000 series and GST IFP8 there is no default loop Right click on the panel under lt FACP Net gt command and select lt Add Loop gt as shown in Fig 20 Fig 20 GstDef3 0 Defining Tool User s Manual Page 12 Fig 21 The lt Loop Number gt is default as next to the previous which can be changed manually But for the system the loop number must be continuous as shown in Fig 21 Note Loop 0 is for repeater panel refer to 5 3 4 Define Repeaters for details The lt Loop Name gt can only be described in the software only but cannot be downloaded to the panel Both Loop Number and Name can be modified later Clicking button can save the changes Refer to Fig 22 Fig 22 5 3 2 4 Upload and Download
24. to the condition or result lt Delete Dev gt Delete a device from the condition or result lt Save Modify gt Save the current equation temporarily lt Save New gt Easily add a similar equation into the temporary database Fig 33 lt Upload gt Upload this piece of equation from panel lt Upload All gt Upload all equations from panel lt Download All gt Download all equations to the panel The equations can be only downloaded together rather than piece by piece lt Delete gt Delete the selected equation lt Save gt Save all equations to the database Note this operation must be done after defining all equations lt Reload gt Restore equation from the last lt Save gt operation The number of devices both in condition and result shall not exceed 10 If more than 10 devices are to be used please split them into two equations 5 3 5 2 Equations in GST200 and GST200 2 1 Define a new equation Click the device cell under the lt Condition Devices gt the cell becomes editable The device number can be input manually An easier way is double clicking the cell again a defined GstDef3 0 Defining Tool User s Manual Page 17 devices list will pop out Choose the device and double click or click lt OK gt button the device will be selected and input to the cell as shown in Fig 34 If more than one device are required in the condition click lt Insert Dev gt to add another device Th