1. Select M Bus Primary Address if the HYDRO PORT is connected to an M Bus repeater HYDRO CENTER and you want to communicate via M Bus The primary address of the HYDRO PORT is used and therefore more M Bus devices than the HYDRO PORT may be connected to the M Bus 6 e OBThe HYDRO PORT Software Standard Template Enter the primary address of the HYDRO PORT 1 250 By default all HYDRO PORT have got primary address 1 If more than one M Bus device with the same primary address is connected to the M Bus the communication will fail Connection C HrDRO PORT Optotransceiver Serial Cable rec sl M Bus Broadcast Addr 254 C M Bus Secondary Address come Ei O M Bus Primary Address 2400Baud sl M Bus Search Program started Help Break HrDRO PORT Device List Device Search Upen Save la 13000024 A D Converter Read Select M Bus Search if you are connected to an M Bus network with multiple HYDRO PORT and you want to automatically create a list of all present HYDRO PORT Once a list is generated it may be saved and loaded later on This list has got the same format as the HYDRO CENTER device list therefore you may use the same lists with both programs For reading a HYDRO PORT select it from the list sorted by serial numbers and press Read The different HYDRO PORT devices are marked in the list with A C and P corresponding to Analog Control and Pulse Main Window HYDRO PORT Address
2. Trouble Shooting Software Installation The software installation stops at a certain point with an error or I after successful installation I am not able to start the HYDRO PORT software e Please install DCOM95 exe if you are using a Windows 95 computers DCOm95 exe is available on the installation CD e Please install at least service pack 4 SP4 if you are using a Windows NT computer e Check the minimum system requirements Optical Communication The optical transceiver is on the HYDRO PORT but I am not able to read the HYDRO PORT e For optical communication the HY DRO PORT has to be connected to the M Bus also Check if the M Bus is connected and if the M Bus power is applied there should be 24 42 V across clamp 19 and 20 e Move the optical transceiver a little bit e Be sure that an optical transceiver is connected to the computer and that the serial port is set correctly e g COM e Use only 300 or 2400 preferred baud e Be sure that the selected serial port 1s not used by other programs remote connection programs Microsoft Active Sync M Bus Communication 1 The HYDRO PORT is connected to the M Bus and I have set M Bus Broadcast Addr 254 It 1s not possible to read the HYDRO PORT 26 e 1BTrouble Shooting Standard Template e Check if the M Bus is connected and if the M Bus power is applied there should be 24 42 V across clamp 19 and 20 e Check if the HYDRO PORT is the only devi
3. HYDRO PORT Analog Input 41 Value 4095 Min 4095 Max 4095 Average 3324 v Min Max Param 1 1 Ex 0 7E Ary VIF Write The parameters values beneath are available Value The currently digitised value of input A1 The range of the value without calculations is 0 4095 A value of 0 signifies 0 mA and a value of 3800 signifies 20 mA approximately All analog inputs are digitised once per second The displayed value is the average of 8 conversions Therefore the display is only refreshed every 8 seconds Min If the calculation of the minimum and maximum values for A is selected the minimum value between two consecutive readouts is displayed here after reading the minimum value it is reset The minimum value is refreshed every 8 seconds Max If the calculation of the minimum and maximum values for A is selected the maximum value between two consecutive readouts is displayed here after reading the maximum value it is reset The maximum value is refreshed every 8 seconds Average If the calculation of the minimum and maximum values for A is selected the average value is displayed here The average value is only reset after reprogramming one of the input channel s parameters It has got a approximate time constant of 17 minutes The average value is refreshed every 8 seconds Param For each analog input it is possible to enter a multiplier divider and offset The HYDRO PORT Analog uses these parameters to
4. HYDROMETER HYDRO PORT r HYDRO PORT Serial Cable directly M Bus Broadcast Addr 254 M Bus Secondary Address com D C M Bus Primary Address 2400 Baud M Bus Search Successi HYDRO PORT Address Re o Red HYDRO PORT Set Address Primary Address 1 Write HYDRO PORT Pulse Input PI zz Serial Number 11000086 Write Medium Unit Electricity Energy kwh gt E 1 Meter Count Factor O 1 000 l 1j PI tea Write All HYDRO FORT Pulse Input P2 1 Serial Number 11000087 White Medium Unit Disabled Volume m3 gt 1 Meter Count Factor T EE 1 000 Pari White All User manual Verison 1 30 HYDROMETER GmbH Ansbach Germany 2000 2009 All rights reserved The name HYDRO PORT the HYDRO PORT software and this manual are protected by copyright laws Copying translating transferring to other media like microfiches and other electromagnetic or optical storage media without the written permission of HYDROMETER is prohibited Trademarks or registered trademarks may be used throughout this manual Even if it 1s not shown explicitly they are protected by copyright laws and belong to their respective owners The HYDRO PORT software and this manual were developed with great precision and tested extensively for being free of errors However it might be possible that undetected errors appear HYDROMETER is no
5. 0 converter raw values For 1 and 2 and the resepctively measured values for and r2 For X1 and X2 the A D converter raw values for the measured values Y1 and Y2 e g height of a water column must be entered Pressing on Calculate Parameters will return the configuration parameters for the HYDOR PORT Analog HYDRO PORT Analog Calculating Values For Temperature Input The calculation of the values of the temperature probe input is almost identical to the calculation of the values of the analog current loop inputs see HY DRO PORT Analog Calculating Values For Al And A2 The only difference is found in the fact that the user definable parameters are additive components to the internal fixed parameters The following parameters are already programmed in the HYDRO PORT Analog Pt100 Mul 42 Div 10 Ofs 274 4 Pt500 Mul 50 Div 10 Ofs 217 0 Pt1000 Mul 150 Div 100 Ofs 143 0 Mul and Div may be changed by 8 7 Ofs by 12 8 12 7 C If you are not able to achieve a correct temperature display with this parameters the calculation must be done in the software module which processes the temperature values e g HY DRO NET virtual TAGs For Pt100 temperature probes the setting beneath may be used Param Do O s 70 PT100 16 e OBThe HYDRO PORT Software Standard Template HYDRO PORT Control HYDRO PORT Control Inputs The states of both digital inputs P1 and P2 are displayed her
6. Buffer Enabled Settings of Bluetooth optical transcereer JAR OH BT Iv IZARA OH BT enabled Manufacturer Code fe HYD C END Cancel Language Select the language of the program texts Currently the HYDRO PORT software is available in English French and German Phone Connection Timeout Enter the time in seconds after which an attempt to establish a phone connection is recognized as failure The default value is between 40 and 60 seconds Modem Initialising If your modem needs a special initialisation command prior to dialling a phone number you can enter the command here Standard Template OBThe HYDRO PORT Software e 23 FiFo Buffer Setting Of Serial Interface Select if the operating system of your PC is using a data buffer FiFo buffer for the serial port or not This parameter may be checked within the settings of your operating system COM ports Setting Of Bluetooth optical transceiver Select this option if you want to use the Bluetooth optical transceiver IZAR OH BT for optical communication In the main screen you just have to select HYDRO PORT Optotransceiver and the COM Port your PC has adapted to the Bluetooth interface You can check this in the Bluetooth manager of your computer Use always 2400 baud for this type of connection Deactivate this option if you use a standard wired opto transceiver 24 e OBThe HYDRO PORT Software Standard Template Standard Template 1BTrouble Shooting e 25
7. HYDRO PORT PUC alia eee alano 19 HYDRO PORT Pulse rees 19 HYDEO SPORT Pulse Input P20 2 aiino dp io eai E ara 20 Disabling HYDRO PORT Pulse Input RIIT 20 PC LOIN TI 23 Trouble Shooting 26 Soltware Installation nante ono eroi rc 26 OppicabCommunieatlofio us cio ele 26 MI B s Communicati On E EEN 26 IME BUS Communicat On 2 aes licia 2I Max Min Average Values Display Analog nennen 24 Parameter e tm T o gliele 28 Pai ATIC LETC LLIN lilla 28 How to do 30 Communication HDRO PORT Optotransceiver eeeeeeeeeeeerererrrerererereanenenanaaa 30 Communication M Bus Broadcast Secondary Primary essen 30 Communication Dial Up Phone Lie uode o a aldeia evo aesti Fea e P Eoo iron cauda 30 Seba TE ke Addis ipa 31 Set a New Secondary Address Analog Control 31 Seb New Parameters CATIalO9 o aieo i d bs eate iliziii 3 set New Parameter Control ille ess ES oso Dose pi de s ui si adamant 3 Set a New Secondary Address or Physical Unit Pulse erre 32 Set a New Meter Count or Factor PUISE ere 32 Disable InputP2 ZIP 32 Index 33 Standard Template Contents e iii The HYDRO PORT Software Main Window Er HYDRO PORT Connection DUE On Uplotranscenei Seral Cable directly E C M Bus Broadcast Addr 254 C M Bus Secondary Address com C M Bus Primary Address 2400 Baud C M Bus Search Program started HYORO PORT Address Re o R
8. OBThe HYDRO PORT Software e 17 0 approx 8 seconds after M Bus power fail the relay output will be set to opened 0 1 approx 8 seconds after M Bus power fail the relay output will be set to closed 1 Write Using the button Write the parameters for output R1 are programmed to the HYDRO PORT Control Please note that you can only program the parameters for one relay output at a given time If you change the parameters for both relay outputs and press the Write button for one output only its respective parameters are programmed the parameters of the other output will be reset to their former state HYDRO PORT Control Relay 2 The state and the parameters for the digital relay output R2 are displayed HYDRO PORT Control Relay H2 State HA 0 Logic Operator M BUS Set D Set At Power Fail ue Write The settings of relay R2 are the the same as of Relay RI 18 e OBThe HYDRO PORT Software Standard Template HYDRO PORT Pulse HYDRO PORT Pulse Input P1 Z2 You are able to set the parameters for pulse input 1 of the HYDRO PORT Pulse here Note that pulse input 1 corresponds to physical contact input P1 and current loop SO input Z2 HYDRO PORT Pulse Input P1 2 Serial Number 12345678 Write Medium Unit Electricity Energy kwh gt 1 Meter Count Factor O 1 000 1 PI 2 Write All You may set all parameter shown in the table beneath Serial En
9. P2 ZI 3 Press Px Zx Write All at HYDRO PORT Input PI Z2 or HYDRO PORT Input P2 ZI 4 If you press Px Zx Write All the serial number medium and physical unit is written also Disable Input P2 Z1 Pulse If you only want to use one input of the HYDRO PORT Pulse you may switch off the second input P2 Z1 In this case the respective serial number secondary address may no longer be used for addressing Proceed as described below 1 Initialise a communication to the HYDRO PORT see Communication HDRO PORT Optotransceiver Communication M Bus Broadcast Secondary Primary Communication Dial Up Phone Line 2 Select Disabled as medium for input P2 Z1 last entry of the list 3 Press Write at HYDRO PORT Input P2 ZI 4 Please note that from this point on the HYDRO PORT is not responding to the secondary address of the input P2 Z1 To enable again this input you have to address the HYDRO PORT Pulse using its primary address or the broadcast address 254 5 This option is only available with all HYDRO PORT Pulse version 2 0 and above You can recognise this version of HYDRO PORT Pulse by checking the serial number which always starts with 11 32 e 2BHow to do Standard Template Index Standard Template 3Bindex e 3 34 e 3Bindex Standard Template Standard Template 3Bindex e 35
10. You have to enter the M Bus address of the HYDRO PORT you want to communicate with see Standard Template OBThe HYDRO PORT Software e 7 Main Window Connection 2 Press Read to start reading the internal parameter of the addressed HYDRO PORT HYDRO PORT Address Read If you have selected HYDRO PORT Optotransceiver or M Bus Broadcast Addr 254 you are not able to enter an address since then the M Bus broadcast address 254 is always used HYDRO PORT Address Secondary Address 12345578 al Media FF Read If you have selected M Bus Secondary Address you have to enter the eight figure M Bus secondary address of one of the HYDRO PORT pulse inputs You can replace single figures of the secondary address with the character F This is a joker which means the figure is arbitrary for addressing the HYDRO PORT If the secondary address is unique in the M Bus network this entry is sufficient and the medium selection may stay on All Media FF Otherwise you have to select the correct medium according to EN 1434 4 also e g Water Only for HYDRO PORT Pulse Please note that using secondary addressing only one pulse input is addressed Only the parameters of this pulse input are shown after reading the HYDRO PORT The parameters of the other pulse input are not shown in this case By default the first pulse input has got the serial number of the HYDRO PORT printed on the sticker of the housing as secondary addre
11. minimum maximum and average values Standard Template OBThe HYDRO PORT Software e 13 HYDRO PORT Analog Calculating Values For A1 And A2 The HYDRO PORT Analog is able to Calculate the digitised values which are in the range of the 12 bit resolution of the A D converter 0 4095 to get a correct display of the value For this purpose a linear regression of the A D converter raw values is made according to the formula y mx b Mul x Ofs Div B Param 1 1 TES In the case Mul 1 Div 1 Ofs 0 is entered the A D converter raw value is displayed A value of 0 is equal to 0 mA a value of 3800 is approximately equal to 20 mA To calculate the parameters for a linear regression of the raw values it 1s necessary to know the raw values for two different real values The example of the measurement of the height of water column in a well should demonstrate this The AID raw value was taken at two different heights of the water column 100 cm and 500 cm Therefore one can calculate y Height of the water column in a well in cm x A D converter raw value y 100 x 345 y2 500 x 2347 Using the formula beneath the parameters m and b may be calculated Mul y2 yi Div x2 xi bebe VIX2 Y2X1 XXe The resolution for the example is 20 m 0 1998 0 2 100 b 31 1 31 In practical terms m 0 2 means that an increase of the A D raw value by 1 corresponds to an increase of t
12. recalculate the digitised values according to the formula y m x b see also HYDRO PORT Analog Calculating Values For A1 And A2 To use real numbers for m this parameter is split into a multiplier and a divider The range of these values is limited to 128 127 Standard Template OBThe HYDRO PORT Software e 11 Unit Select a unit from the list of available units according to EN 1434 4 If the unit you want is not available please select JE Any VIF The M Bus units 7B 7C 7D and 7F are not programmable and will be automatically set to 7E Any VIF Write Pressing the button Write will program the calculating parameters min max display setting and the physical unit for input Al into the HYDRO PORT Analog Please note that only the parameters for one input may be programmed at once If you change the parameters of more than one input the parameters for all other inputs except the one you have programmed are overwritten with the previous values HYDRO PORT Analog Input A2 This field is for setting the parameters of analog input A2 of the HYDRO PORT Analog HYDRO PORT Analog Input Value 4095 Min Max Param iE ilg D 7E Ary VIF Write HYDRO PURT Analog Input A E Value 4095 Min 3583 Max 4095 Average 4038 M Min Max Param 1E im O 7E Ary VIF Write The entry of the parameters of input A2 is the same as of input Al 12 e OBThe HYDRO PORT Software Standard Temp
13. Connection C HYDRO PORT Optotransceiver Serial Cable directly C M Bus Broadcast Addr 254 M Bus Secondary Address com El C M Bus Primary Address 2400 Baud C M Bus Search Select Serial Cable directly if the HYDRO PORT is connected to an M Bus repeater H YDRO CENTER via M Bus and the M Bus repeater is directly connected to the computer This option is also used for communication via optical interface Select the serial port of your computer to which the M Bus Repeater or the optical converter is connected Use 2400 baud as default baudrate Only with very long M Bus cables or noisy M Bus connections use 300 baud You may not use other baudrates for this communication type Connection C HYDRO PORT Optotransceiver Modem Dial Up Connection C M Bus Broadcast Addr 254 dia comi sl Phone 0123456789 C M Bus Primary Address 13200 Baud Test Connection 1 C M Bus Search Phonenumber Connect Help Break Select Modem Dial Up Connection if the HYDRO PORT is connected to an M Bus repeater HYDRO CENTER via M Bus and the M Bus repeater is connected to the computer via dial up phone line Additionally you have to enter the phone number of the remote system where the HYDRO PORT is installed The phone number may contain dial commands for the modem e g a 2 e OBThe HYDRO PORT Software Standard Template comma for a delay during dialling Using the built in phone number administration you
14. are able to store the most used phone numbers to your remote systems Select the serial port of your computer to which the modem is connected Use 19200 baud as default baudrate Only with noisy phone connections use 9600 baud You may not use other baudrates for this communication type Before you are able to communicate with the HYDRO PORT you have to establish a connection to the remote system Enter the phone number or select one from the list of stored phone numbers and press Connect If the connection is established you are able to communicate with the HYDRO PORT You should close the phone connection afterwards by pressing Hang Up Connection HYDRO PORT Optotransceiver Optica Connection IADA SIR Notebook M Bus Broadcast ddr 254 M e Secondary Address come El C M Bus Primary Address C M Bus Search Select Optical Connection IRDA SIR Notebook if the HYDRO PORT is connected to an M Bus repeater HY DRO CENTER via M Bus and the M Bus repeater is connected to the computer e g a notebook via optical IRDA interface Select the serial port of your computer to which the IRDA module is connected The baudrate is fixed to 38400 baud and therefore you are not able to select it Connection C HYDRO PORT Optotransceiver Optical Connection IRDA HY Optotransceiver C M Bus Broadcast Addr 254 M Bus Secondary Address Slab C M Bus Primary Address C M Bus Search Help Break Select Op
15. ce connected to the M Bus If not you have to disconnect all other devices or use the primary or secondary address of the HYDRO PORT e Select only 300 or 2400 baud Usually you should use 2400 baud Only with very long M Bus cable connections or noisy M Bus connections you should use 300 baud e Be sure that the selected serial port is not used by other programs remote connection programs Microsoft Active Sync M Bus Communication 2 The HYDRO PORT is connected to the M Bus and M Bus Secondary Address or M Bus Primary Address is selected It is not possible to read the HYDRO PORT e Check if the M Bus is connected and if the M Bus power is applied there should be 24 42 V across clamp 19 and 20 e Check if the secondary address is correct By default the secondary address for pulse input 1 is the serial number of the HY DRO PORT placed on a sticker on the HY DRO PORT and serial number 1 for pulse input 2 If you do not know the HYDRO PORT secondary address any more you have to perform an M Bus slave search using e g the HYDRO CENTER software or use the on site communication with an optical transceiver e Check if the primary address is correct By default the primary address is 1 If you do not know the primary address any more you have to perform an M Bus slave search using e g the HY DRO CENTER software or use the on site communication with an optical transceiver If there are several devices with the same primary add
16. cond input P2 Z1 may be disabled In this case the respective secondary address serial number can no longer be addressed To disable the second input select Disabled as medium last entry of the list e Only input P2 Z1 may be switched off e Ifinput P2 ZI is disabled only the secondary addressing of this input is disabled The pulse counting continues e Input P2 ZI may only be enabled again if the HYDRO PORT is addressed using its primary address or the broadcast address 254 e This option is only available with HYDRO PORT Pulse version 2 0 and above This version may be recognised by the serial number which always starts with 11 HYDRO PORT Pulse Input P2 7 1 Serial Number 11000087 Medium Unit Disabled Volume m3 gt 1 Meter Count Factor O 1 000 1 rezza 20 e OBThe HYDRO PORT Software Standard Template Switching off the second input has got the advantage that an M Bus search may be terminated much faster Standard Template OBThe HYDRO PORT Software e 21 22 e OBThe HYDRO PORT Software Standard Template Settings Click on the program icon in the upper left corner of the main window and select Settings from the upcoming menu The dialog beneath appears HYDRO PORT Settings xj Language Select a language RL Ed Phone Connection Timeout has time for establishing connection sec Ei Modem lnitialising AT Command FiFa Buffer Setting Of Seral Interface Iw FiFo
17. e They can be 0 open or 1 closed HYDRO PORT Control Inputs State PI 0 State Pe HYDRO PORT Control Relay 1 The state and the parameters for the digital relay output RI are displayed HYDRO PORT Control Relay F1 State H1 Logic Operator M BUS Set Set 1 At Power Fail ata write The parameters values beneath are available State R1 The switching state of relay RI is displayed 0 open 1 closed If there is a difference between the current state and the programmed state an error will be displayed Differences may occur if the relay is switched to rapidly In this case the capacitor for driving the relays is drained It may take up to 30 minutes until the switching state 1s correct again Set 0 Sets or resets the relay 0 open 1 close These buttons are Set 1 only enabled if the switching state is to be set manually see logic operator Logic Select whether the relay switching state should be set Operato manually setting M Bus or if the switching state should r depend on state of the digital inputs Example PI AND P2 will close 1 the relay if both digital inputs P1 and P2 are closed 1 There are an overall of 16 different logic operators used with P1 and P2 to set reset the reley output P1 stands for NOT P1 At You may select the state of the relay output in case of an M Power Bus power fail Fail no change of relay output Standard Template
18. ed HYDRO PORT Set Address Primary Address Wi rite Hy DRO PORT After start up of HY DRO PORT you will see the main dialog window which is divided in four parts e Connection Within this frame you set how to communicate with the HY DRO PORT and how the connection to the HYDRO PORT is established Standard Template OBThe HYDRO PORT Software e 1 e HYDRO PORT Address Depending on the communication type the primary M Bus address or the secondary M Bus address of the HYDRO PORT must be inserted here e HYDRO PORT Set Address Depending on the type of HYDRO PORT it is here possible to set a new M Bus primary address 1 250 or a new primary address together with a new secondary address serial number The HYDRO PORT Pulse has got two secondary addresses for each pulse input respectively and therefore the secondary addresses for this device are set elsewhere The HYDRO PORT Analog and HYDRO PORT Control have got only one secondary address e HYDRO PORT Within this field the HYDRO PORT parameters and values will be displayed and set Depending on the HYDRO PORT type this field will look differently as will be described later on Main Window Connection 1 There are four different ways to establish a connection from an M Bus repeater HYDRO CENTER to a HYDRO PORT as shown beneath However these settings are not to be mixed up with the setting of the addressing of the HYDRO PORT see Main Window Connection 2
19. entry fields at HYDRO PORT Analog Input A1 or HYDRO PORT Analog Input A2 respectively 3 Press Write at HYDRO PORT Analog Input Al or HYDRO PORT Analog Input A2 respectively Set New Parameter Control 1 Initialise a communication to the HYDRO PORT see Communication HDRO PORT Optotransceiver Communication M Bus Broadcast Secondary Primary Communication Dial Up Phone Line 2 Select in the fields HYDRO PORT Control Relay R1 or HYDRO PORT Control Relay R2 respectively at Logic Operator and At Power Fail your options 3 Press Write at HYDRO PORT Control Relay R1 or HYDRO PORT Control Relay R2 respectively Standard Template 2BHow to do e 31 Set a New Secondary Address or Physical Unit Pulse 1 Initialise a communication to the HYDRO PORT see Communication HDRO PORT Optotransceiver Communication M Bus Broadcast Secondary Primary Communication Dial Up Phone Line 2 Enter the new serial number medium and physical unit at HYDRO PORT Input PI Z2 or HYDRO PORT Input P2 Z1 3 Press Write at HYDRO PORT Input PI Z2 or HYDRO PORT Input P2 ZI Set a New Meter Count or Factor Pulse 1 Initialise a communication to the HYDRO PORT see Communication HDRO PORT Optotransceiver Communication M Bus Broadcast Secondary Primary Communication Dial Up Phone Line 2 Enter the new meter count and factor at HYDRO PORT Input P1 Z2 or HYDRO PORT Input
20. he water column by 0 2 cm Additionally b 31 means that at a A D raw value of 0 the height of the water column is 31 cm Therefore the parameters should be set as shown beneath to get a correct display of the height of the water column in cm 14 OBThe HYDRO PORT Software Standard Template Param Al 100 x al Please note that the range of the values of the parameters is only 128 127 If you are not able to find parameters for a certain purpose you have to use another value base e g instead of height in cm height in dm or meter or the calculating of the values must be done in some other software e g HYDRO NET virtual TAG For the later case the parameter should always be set to the standard values Mul 1 Div 1 Ofs 0 HYDRO PORT Analog Calculation Dialog The calculation from the previous chapter can also be done by the HYDRO PORT software itself Click on one of the Param buttons and the dialog for analogue parameter calculation appears alternatively if e g a HYDRO PORT Analog was not read and therefore the HYDRO PORT Analog entry fields are not visible the menu entry Parameter Calculation For Analog Input can also be used EM HYDRO PORT 1 29 Parameter Calculation Far Analog Input ege LI Settings About HYDRO PORT Standard Template OBThe HYDRO PORT Software e 15 The following dialog appears Parameter Calculation For Analog Input Please enter the 4
21. her M Bus devices are not shown but will remain in the list Main Window HYDRO PORT Set Address You are able to set a new primary and secondary address here All HY DRO PORT even the HYDRO PORT Pulse have got exactly one primary address Only the HYDRO PORT Pulse has got two secondary addresses therefore the secondary addresses for this device are not set in here but in another field of the main program window With the HY DRO PORT Analog and HYDRO PORT Control the secondary address is also displayed here HYDRO FORT Set Address Primary Address 42 Write HYDRO FORT Set Address Secondary Address 12000035 Primary Address 10 Write Connect the HYDRO PORT to the M Bus and select the correct communication type Press Read to communicate with the HYDRO PORT After the internal HYDRO PORT parameters are read you may enter a new primary address 1 250 and press Write The new primary address is then written permanently to the HYDRO PORT With the HYDRO PORT Analog and HYDRO PORT Control the secondary address is also set here Usually the secondary address should be the serial number Standard Template OBThe HYDRO PORT Software e 9 10 e OBThe HYDRO PORT Software Standard Template HYDRO PORT Analog HYDRO PORT Analog Input A1 This field is for setting the parameters of analog input Al of the HYDRO PORT Analog HYDRO PORT Analog Input amp 1 Value 4095 Min Max Param 104 1 Fr D 7E Any VIF Write
22. late HYDRO PORT Analog Temperature Sensor Input Pt Here you are able to set the parameters of the temperature sensor input Pt of the HY DRO PORT Analog HYDRO PURT Analog Temperature Sensor Input Pt Value 38 0 E Min Max Param n 0 NES 10 0 PT100 Write HYDRO PURT Analog Temperature Sensor Input Pt Value 133 Mm 135 Max 19 9 Average 13 5 ae v Min Max Parar Oo fx 10 0 PT100 Write The entry of the parameters of temperature sensor input Pt is roughly the same as of Input Al The differences are listed beneath Param As for the other analog inputs you are also able to enter a multiplier divider and offset Multiplier and divider only have a range of 8 7 In contrary to the other analog inputs the parameters entered here are only additional additive components which are added to the pre programmed values in the HY DRO PORT Analog see also HYDRO PORT Analog Calculating Values For Temperature Input Temperature You may connect a Pt100 Pt500 or Pt1000 to the Sensor Selection HYDRO PORT Analog temperature sensor input The HYDRO PORT Analog has got a set of parameters for each sensor type Additionally a different signal pre amplification is used for Pt100 and Pt500 1000 If you are not able to find parameters for a correct display of the temperature with the sensor used you may also read the digitised raw values However in this case it is not possible to record
23. mplate 5 Enter a phone number or select one from the list of the phone number administration 6 Press Connect 7 Wait until the connection is established 8 Enter the secondary or primary address of the HYDRO PORT if necessary 9 Press Read 10 Perform the necessary HYDRO PORT parameter settings 11 Disconnect by pressing Hang Up Set a New Primary Address 1 Initialise a communication to the HYDRO PORT see Communication HDRO PORT Optotransceiver Communication M Bus Broadcast Secondary Primary Communication Dial Up Phone Line 2 Enter the new primary address at HYDRO PORT Both Inputs 3 Press Write at HYDRO PORT Set Address Set a New Secondary Address Analog Control 1 Initialise a communication to the HYDRO PORT see Communication HDRO PORT Optotransceiver Communication M Bus Broadcast Secondary Primary Communication Dial Up Phone Line 2 Enter the new secondary address at Secondary Address within the field HYDRO PORT Set Address Please note that you are only able to set the primary and secondary addresses of HYDRO PORT Analog and HYDRO PORT Control simultaneously 3 Press Write at HYDRO PORT Set Address Set New Parameters Analog 1 Initialise a communication to the HYDRO PORT see Communication HDRO PORT Optotransceiver Communication M Bus Broadcast Secondary Primary Communication Dial Up Phone Line 2 Enter multiplier divider and offset within the respective
24. n M Bus repeater HYDRO CENTER and you want to communicate via M Bus The secondary address of one of the HYDRO PORT inputs is used and therefore more M Bus devices than the HYDRO PORT may be connected to the M Bus Enter the secondary address serial number of one of the HYDRO PORT inputs If the secondary address is unique on the M Bus you do not have to enter the correct media but leave the respective entry field at FF All Media However if the serial number is not sufficient for addressing the HYDRO PORT you have to select the correct medium from the list according to EN 1434 4 Please note that each HY DRO PORT has got two secondary addresses for each of its pulse inputs respectively If you are using secondary addresses you are only addressing one of the pulse inputs at a time and therefore only the parameters of the addressed pulse input are shown With all other types of addressing the parameters for both pulse inputs are shown always By default the first pulse input has got the serial number of the HY DRO PORT printed on the sticker of the housing as secondary address and the second pulse input has got serial number 1 as secondary address Connection C HYDRO PORT Optotransceiver Serial Cable directly C M Bus Broadcast Addr 254 C M Bus Secondary Address come Ce M Bus Primary Address 2400 Baud C M Bus Search Program started Help Break HYDRO PORT Address Primary Address 123 Read
25. partnership between the IZAR OH BT and your PC using the Bluetooth Manager of your computer Please note which COM port will be assigned to the Bluetooth interface It must be in a range from 1 to 32 Now choose the connection type HYDRO PORT Optotransceiver and set the assigned COM port Use always 2400 Baud for this connection type Connection C HYDRO PORT Optotransceiver Seria Cable directly C Mus Second Address CoM C M Bus Primary Address 2400 Baud C M Bus Search Ce Po Help Heak HYDOR FORT Address Read Select M Bus Broadcast Addr 254 if the HYDRO PORT is the only M Bus device connected to an M Bus repeater HYDRO CENTER and you want to communicate via M Bus The M Bus Standard Template OBThe HYDRO PORT Software e 5 broadcast address 254 is used and therefore all devices connected to the M Bus are answering With this setting you will not be able to communicate with the HY DRO PORT if there are any other devices connected to the M Bus You are not able to enter a HYDRO PORT address since the M Bus broadcast address 254 is always used Connection C HYDRO FORT Optotransceiver Serial Cable directly C M Bus Broadcast Addr 254 Bus Secondary Address com2 El C M Bus Primary Address 2400 Baud C M Bus Search Help Break Hr DOR PORT Address Secondary Address 12345578 al Media FF Read Select M Bus Secondary Address if the HYDRO PORT is connected to a
26. plate 2BHow to do e 29 How to do Communication HDRO PORT Optotransceiver dc a DE eS ES Connect the optical transceiver to an unused serial port of your computer Select HYDRO PORT Optotransceiver Select the correct serial port e g COM2 Select 2400 baud Connect the HY DRO PORT to the M Bus The M Bus delivers the power supply for the HY DRO PORT Put the HY DRO PORT optical transceiver in the middle of the top of the HY DRO PORT housing Press Read If the communication progress bar is not proceeding move the optical transceiver a little bit Communication M Bus Broadcast Secondary Primary l Di 3 Select M Bus Broadcast Addr 254 M Bus Secondary Address or M Bus Primary Address Select Serial Cable directly Select the correct serial interface port to which the M Bus repeater HYDRO CENTER is connected e g COM2 4 5 6 7 Select 2400 baud Connect the HYDRO PORT to the M Bus The M Bus delivers the power supply for the HY DRO PORT Enter the secondary or primary address of the HYDRO PORT if necessary Press Read Communication Dial Up Phone Line 1 2 3 4 Select M Bus Broadcast Addr 254 M Bus Secondary Address or M Bus Primary Address Select Modem Dial Up Connection Select the correct serial interface port to which the modem is connected e g COM2 Select 19200 baud or 9600 baud for noisy phone connections 30 e 2BHow to do Standard Te
27. r count P1 Z2 Write All Standard Template OBThe HYDRO PORT Software e 19 By pressing P1 Z2 Write All all parameter entries for pulse input 1 are permanently written to the HYDRO PORT including serial number medium physical unit meter count and factor Please note that you are only able to write the parameters for one pulse input at a time This means if you want to set the parameters for both pulse inputs you have to enter and write the parameters for the first pulse input and the one for the second afterwards Otherwise the entered parameters for the second pulse input are overwritten with the read parameters from the HYDRO PORT Pulse Therefore enter the parameters for the first pulse input first and write them to the HYDRO PORT Pulse Afterwards enter the parameters for the second pulse input and write them to the HYDRO PORT Pulse also HYDRO PORT Pulse Input P2 Z1 You are able to set the parameters for pulse input 2 of the HYDRO PORT Pulse here Note that pulse input 2 corresponds to physical contact input P2 and current loop SO input Z1 HYDRO PORT Pulse Input P2 2 Serial Number Brbb4321 write Medium Unit water E Volume m3 gt 1 Meter Count Factor 1 000 1 Portel White All The parameter setting of pulse input P2 Z1 is the same as of pulse input PI Z2 Disabling HYDRO PORT Pulse Input P2 Z1 If only one input of the HYDRO PORT Pulse will be used the se
28. rd Template Main Window Connection 2 There are five different ways to address a HYDRO PORT as shown beneath However these settings are not to be mixed up with the setting of the connection type see Main Window Connection 1 Connection GG HYDR O PDRT Optotransceiver Serial Cable directly C M Bus Broadcast Addr 254 C M Bus Secondary Address coM C M Bus Primary Address 2400 Baud C M Bus Search PO Doo Help Break HYDOR FORT Address Read Select HYDRO PORT Optotransceiver if you have put the HYDROMETER optotransceiver directly on the housing of the HYDRO PORT and want to use the optical interface to communicate The optotranceiver is always connected directly to the serial port of a computer therefore you are not able to select the communication type Selcect the correct serial interface port and use 300 or 2400 preferred baud You are not able to enter a HYDRO PORT address since the M Bus broadcast address 254 is always used For communication using the HYDROMETER optotransceiver connect it to a serial port of your computer and put the optotransceiver in the middle of the top surface of the HY DRO PORT housing If you are not able to communicate the progress bar is not moving on move the optotransceiver a little bit If you want to use the Bluetooth optical transceiver IZAR OH BT you have to activate the corresponding option in the settings dialog After that you have to generate a connection
29. ress connected to the M Bus the communication will always fail e Select only 300 or 2400 baud Usually you should use 2400 baud Only with very long M Bus cable connections or noisy M Bus connections you should use 300 baud e Be sure that the selected serial port is not used by other programs remote connection programs Microsoft Active Sync Max Min Average Values Display Analog After changing the parameters of an analog input or after changing the min max setting the min max values and the average value are displaying erroneous values e This is not an error After reprogramming the parameters of an analog input the respective values are reset The correct values will be displayed after 8 seconds after the next refresh cycle Standard Template 1BTrouble Shooting e 27 Parameter Setting 1 The HYDRO PORT is connected to the M Bus and M Bus Secondary Address is selected After reading the HY DRO PORT only the parameters for one pulse input are shown e This is correct Using secondary addressing only the parameters of the addressed pulse input are shown Parameter Setting 2 One of the HYDRO PORT pulse inputs is programmed with a non integer factor e g 80 50 After writing the meter count has changed e Please note that an integer division is used Therefore the rest of the division is not taken and the meter count may change after writing the factor 28 e 1BTrouble Shooting Standard Template Standard Tem
30. ss and the second pulse input has got serial number 1 as secondary address HYDRO FORT Address Primary Address 123 Head If you have selected M Bus Primary Address you have to enter the primary address of the HYDRO PORT 1 250 By default all HYDRO PORT have got primary address 1 HYDRO PFORT Device List l Device Search Upen dave Ta 13000024 A D Converter Read If you have selected M Bus Search you are able to start an automatic search for all HYDRO PORT connected to the network This search will only look for HYDRO PORT other M Bus device are not taken into account To Start the search press Devicesearch The procedure may take from several seconds to hours depending on the baudrate and the number of HYDRO PORT connected to the network 8 OBThe HYDRO PORT Software Standard Template After the search has been finished successfully all HYDRO PORT found are written to the selection list which is sorted by their respective type A C P and serial number Click on the list to select the HYDRO PORT you want to read and press Read afterwards Secondary addressing is used therefore with HY DRO PORT Pulse only one pulse input is displayed A device list may be saved to a file and loaded later on The format of this list is the same as the HYDRO CENTER device list therefore both programs can use the same lists However the HYDRO PORT software is only displaying HYDRO PORT devices in the selection list ot
31. t liable for any incidental indirect or consequential damages whatsoever regarding this product the use of this product or the inability to use this product including but not limited to damages for loss of business profits business interruption loss of business information or any other pecuniary loss HY DROMETER s entire liability is limited to the price paid for this product The latest version of this manual is located at http www hydrometer com systems Downloadcenter html Hydrometer GmbH Industriestrasse 13 91522 Ansbach GERMANY Email Info hydrometer de Internet www hydrometer de Contents The HYDRO PORT Software 1 Main ndo Wo sites nus E tas eect coat AD Ri Ra GOA RE E aa Cro Da DE Ed 1 Main Window Connection ln 2 Phone Number Administration erinnere a 3 Main Window Connection 2 irie E sentes senten 3 Main Window HYDRO PORT Address 7 Main Window HYDRO PORT Set Address 9 FRY DRO P OR VF Anal EE 11 HYDRO PORT Analog Input Alison II HYDRO PORT Analog Input E 12 HYDRO PORT Analog Temperature Sensor Input Pt M 13 HYDRO PORT Analog Calculating Values For Al And A2 sss 14 HYDRO PORT Analog Calculation Dialog ii 15 HYDRO PORT Analog Calculating Values For Temperature Input 16 PRY DI RO2EOR TC Omir lalla 17 SKI RTR ee DN ue 17 HXYXDRO PORECntoReav csrl 17 HMDRO PORT ConttoRelay2 sasleraa dd Dai deene 18
32. ter the secondary address of pulse input 1 Usually the M Number Bus secondary address corresponds to the serial number of the meter connected to the respective pulse input Medium Select a medium for the connected meter from the list according to EN 1434 4 The medium may be used for secondary addressing Unit Select a physical unit from the list according to EN 1434 4 Four standard units Energy Wh Energy kWh Volume 1 Volume m3 are placed at the beginning of the list The M Bus units 7B 7C 7D and 7F are not programmable and will be automatically set to 7E Any VIF Meter Enter the meter count here The meter count is the current Count count after applying the factor Factor Before outputting the meter count to the M Bus the internal pulse counter of the HYDRO PORT is multiplied with the given multiplier and divided by the given divisor The resulting factor is displayed in the yellow field at the right hand side of the factor input Please note that only an integer division is performed Therefore the meter count may change after setting it if the divisor is not equal to 1 Write By pressing Write the serial number medium and physical unit for pulse input 1 are permanently written to the HYDRO PORT Pulse However the entries for meter count and factor are not written This makes sense if you only want to write the fixed parameters of the HYDRO PORT pulse input 1 and do not want to disturb the self incrementing mete
33. tical Connection IRDA HY Optotransceiver if the HYDRO PORT is connected to an M Bus repeater HYDRO CENTER via M Bus and the M Bus repeater is connected to the computer via HYDROMETER IRDA optotranceiver Select the serial port of your computer to which the HYDROMETER IRDA optotranceiver is connected The baudrate is fixed to 38400 baud and therefore you are not able to select it Phone Number Administration The HYDRO PORT software contains a list where often used phone numbers can be stored Select Modem Dial Up Connection and press Phonenumber The dialog beneath appears Standard Template OBThe HYDRO PORT Software e 3 Phonenumbers Description Test Connection 1 01 2345 67890 Test Connection 2 09876 54321 New Enter the description and the respective phone number you want to add to the list The phone number may contain dial commands to your modem e g a comma for a delay during dialling Phonenumber Hew Edit Description Test Connection 1 Phonenumber o 2345 67090 Cancel Edit Select an entry from the list and press Edit The same dialog as for New appears and you are able to edit an existing phone number Delete Select an entry from the list and press Delete The selected entry is deleted from the list For selecting a phone number you have to single click an entry and confirm with OK alternatively you may also double click the entry 4 e OBThe HYDRO PORT Software Standa
Download Pdf Manuals
Related Search
Related Contents
USER'S MANUAL Toshiba AT305-SP0201L 16GB Black Alltagsdefinitionen und ihre Funktionen - MADOC Wiley Professional LINQ Guide de l`utilisateur et notice de garantie instructivo para la prestación de servicios de control de plagas Using Infortrend EonStor FC-host Storage with HP Copyright © All rights reserved.