1. 12 Weight 245g 1 2 Main Functions 1 ot ee OT ee 9 Capable of performing measurements on a wide range of material including metals plastic ceramics composites epoxies glass and other ultrasonic wave well conductive materials Transducer models are available for special application including for coarse grain material and high temperature applications Probe Zero function Sound Velocity Calibration function Two Point Calibration function Two work modes Single point mode and Scan mode Coupling status indicator showing the coupling status Battery information indicates the rest capacity of the battery Auto sleep and auto power off function to conserve battery life Optional software to process the memory data on the PC for MT160 10 Optional thermal mini printer to print the measured data via RS232 port for MT160 1 3 Measuring Principle The digital ultrasonic thickness gauge determines the thickness of a part or structure by accurately measuring the time required for a short ultrasonic pulse generated by a transducer to travel through the thickness of the material reflect from the back or inside surface and be returned to the transducer The measured two way transit time is divided by two to account for the down and back travel path and then multiplied by the velocity of sound in the material 4 The result is expressed in the well known relationship vxt H e Where HO Thickness of the
2. 4 Operation 4 1 Power On Off The instrument is turned on by pressing the key fe NS a E ee M S mm MM Gu con ypg The gauge can be turned off by pressing the key while it is on The tool has a special memory that retains all of its settings even when the power is off 4 2 Probe Zero The I key is used to zero the instrument in much the same way that a mechanical micrometer is zeroed If the gauge is not zeroed correctly all the measurements that the gauge makes may be in error by some fixed value When the instrument is zeroed this fixed error value is measured and automatically corrected for all subsequent measurements The instrument may be zeroed by performing the following procedure 1 Plug the transducer into the instrument Make sure that the connectors are fully engaged Check that the wearface of the transducer is clean and free of any debris 2 Press the key to activate the probe zero mode 14 3 Use the amp key and the key to scroll to the probe model currently being used Be sure to set the right probe model to the instrument Otherwise there will be erroneous 4 Apply a single droplet of ultrasonic couplant to the face of the metal probe disc 5 Press the transducer against the probe disc making sure that the transducer sits flat against the surface 6 Remove the transducer from the probe disc At this point the instrument has successfully calc
3. turn on it only when necessary 4 12 Battery Information Two AA size alkaline batteries are needed as the power source After several hours usage of the preset batteries the battery symbol on the screen will be shown as Ln The more of dark part indicates the more close to fill When the battery capacity runs out the battery symbol will be shown as 1__ and will begin to flash When this occurs the batteries should be replaced Please take out the batteries when not working during a long period of time 4 13 Auto Power Off The instrument features an auto power off function designed to conserve battery life If the tool is idle for 5 minutes it will turn itself off While the voltage of the battery is too low this function will also work 4 14 System Reset Press down the key while powering on the instrument will restore factory defaults All the memory data will be cleared during system reset The only time this might possibly helpful is if the parameter in the gauge was somehow corrupted 4 15 Connecting to a Computer MT160 is equipped with a RS232 serial port Using the accessory cable the gauge has the ability to connect to a computer or external storage device Measurement data stored in the memory of the gauge can be transferred to the 25 computer through the RS232 port Detailed information of the communication software and its usage refer to the software manual 5 Servicing When the hardness tester appears some
4. Press the key to exit the data logging functions and return to measurement mode 23 4 9 Data Printing At the end of the inspection process or end of the day the user may require the readings be transferred to a computer The following steps outline this procedure This function is only available for MT160 and not for MT150 1 Before printing please insert one connection plug of the print cable Optional parts into the socket on the up left of the main body and insert the other plug into the communication socket of the mini printer 2 Press the key to activate the data logging functions 3 Use the key and the key to select the desired file 4 Press the l key to print the selected file This operation will send all the data in current file to the mini printer via RS232 port and print them out 5 Press the key to exit the data logging functions and return to measurement mode 4 10 Beep Mode When the beep is set to On it would make a short hoot while press the key each time on each measurement or the measured value exceeds the tolerance limit Press the key to switch the beep mode on and off It will display the current beep mode on the main screen 4 11 EL Backlight With the background light it is convenient to work in the dark condition Press key to switch on or switch off the background light at any moment as you need after power on 24 Since the EL light will consume much power
5. responsible for conducting ultrasonic sound into the material being measured and the other semicircle is responsible for conducting the echoed sound back into the transducer When the transducer is placed against the material being measured it is the area directly beneath the center of the wearface that is being measured Right figure is a top view of a typical transducer Press against the top with the thumb or index finger to hold the transducer in place Moderate pressure is sufficient as it is 11 only necessary to keep the transducer stationary and the wearface seated flat against the surface of the material being measured Table 3 1 Transducer Selection Model Freq Diam Measuring Lower Description MHz mm Range limit N02 2 5 14 3 0mm 20mm for thick highly 300 0mmf In attenuating or Steel highly scattering 40mm in materials Gray Cast Iron HT200 NO5 5 10 1 2mm 20mm Normal 230 0mm Inx 3 0mm Measurement Steel NO5 5 10 1 2mm 20mm Normal 90 230 0mm Inx 3 0mm Measurement Steel NO7 7 6 0 75mm 15mm For thin pipe wall 80 0mm x 2 0mm or small 0 In Steeg curvature pipe wall measurement HT5 5 14 30 200mm 30mm For high O In Steelg temperature lower than 300 C measurement 12 3 2 Condition and Preparation of Surfaces In any ultrasonic measurement scenario the shape and roughness of the test surface are of paramount importance Rough u
6. that the transducer sits flat against the surface of the sample The display should show some probably incorrect thickness value and the coupling status indicator should appear steadily 4 Having achieved a stable reading remove the transducer If the displayed thickness changes from the value shown while the transducer was coupled repeat step 3 5 Press the key The MM or IN symbol should begin flashing 6 Use the key and the key to adjust the displayed thickness up or down until it matches the thickness of the sample piece 7 Press the key The display will flash 1OF2 Repeat steps 3 through 6 on the second calibration point 18 8 Press the key so that The M S or IN u S symbols are flashing The gauge will now display the sound velocity value it has calculated based on the thickness values that were entered in step 6 9 Press the key once more to exit the calibration mode The gauge is now ready to perform measurements within this range 4 4 Making Measurements When the tool is displaying thickness measurements the display will hold the last value measured until a new measurement is made In order for the transducer to do its job there must be no air gaps between the wear face and the surface of the material being measured This is accomplished with the use of a coupling fluid commonly called couplant This fluid serves to couple or transfer the ultrasonic sound waves from the t
7. the battery 4 Information Display Displays the measured thickness value the sound velocity and shows hints of current operation 2 2 Keypad Definitions Data Save or Data Turn the instrument Sound velocity on off CAL calibration Turn on off the EL Enter backlight Probe Zero Plus PRE operation kis Turn on off Scan mode Unit switch between a em Minus Metric and Imperial 4 Turn on off the system beep mode fe Delete 3 Preparation 3 1 Transducer Selection The gauge is inherently capable of performing measurements on a wide range of materials from various metals to glass and plastics Different types of material however will require the use of different transducers Choosing the correct transducer for a job is critical to being able to easily perform accurate and reliable measurement The following paragraphs highlight the important properties of transducers which should be considered when selecting a transducer for a specific job Generally speaking the best transducer for a job is one that sends sufficient ultrasonic energy into the material being measured such that a strong stable echo is received by the gauge Several factors affect the strength of ultrasound as it travels These are outlined below Initial Signal Strength The stronger a signal is to begin with the stronger its return echo will be Initial signal strength is largely a factor of the size of t
8. M T 150 160 Ultrasonic Thickness Gauge User s M anual LOVENIE W Si atte iO these ia i e aeaa 3 1 1 Product Specifications W asaeanneee 3 TZ MAIN Functions a a Oa 4 1 3 Measuring Principle saccctsccsssesdseseieeencderesetonse 4 1 4 COMMGUPATI ONS ccc sees ants lt qeissniiinsd nia teeckvaseaandecesde 5 1 5 Operating Conditions 0 0 0 eee ececeeseeeeeneeees 6 2 Structure FOALUNC icescccsreadevssucreacessencoussungeseseecatedasns 6 2 1 Main SCIEN cc ascassacntocssuceuseastvatnuiwensessacrspionnoes 7 2 2 Keypad Definitions ee ececeesecneereeeeeenees 8 Preparation sas saeiet uae nitacehle oon tn cok meaty chia 9 3 1 Transducer Selection cc eccceeseceeeneeteeees 9 3 2 Condition and Preparation of Surfaces 13 A Operati Menini enn e a A Ea 14 41 Power OMO ffi menene a 14 4 2 Probe ZOO vsstaade aioe dasesentaheosonoactascan gues 14 4 3 Sound Velocity Calibration eee 15 4 4 Making Measurement c ceeeeeteeeteeeeees 19 4 5 SCAM INOS ee a E a S E Ace 20 4 6 Changing Resolution ei eeeeeeeeeeteeeeees 21 4 7 Changing UNIS sosencenersevesnnesecespabereeneaatoass 22 4 8 Memory Management cccceceeceeeceteeeeees 22 4 9 Data PuntiniGateghc cid ree laa te acter neue 24 4 10 Beep Mode tiiccsccscss cates ssaceaceisa tudes sive scaaceniposas 24 4 11 EL Backlight 24 4 12 Battery Information s esssenseeesssesesseeessessesee 25 4 13 Auto Power Off eseeseseesse
9. act with a hot surface it will begin to heat up and through thermal 29 expansion and other effects may begin to adversely affect the accuracy of measurements Measuring laminated materials Laminated materials are unique in that their density and therefore sound velocity may vary considerably from one piece to another Some laminated materials may even exhibit noticeable changes in sound velocity across a single surface The only way to reliably measure such materials is by performing a calibration procedure on a sample piece of known thickness Ideally this sample material should be a part of the same piece being measured or at least from the same lamination batch By calibrating to each test piece individually the effects of variation of sound velocity will be minimized An additional important consideration when measuring laminates is that any included air gaps or pockets will cause an early reflection of the ultrasound beam This effect will be noticed as a sudden decrease in thickness in an otherwise regular surface While this may impede accurate measurement of total material thickness it does provide the user with positive indication of air gaps in the laminate Suitability of materials Ultrasonic thickness measurements rely on passing a sound wave through the material being measured Not all materials are good at transmitting sound Ultrasonic thickness measurement is practical in a wide variety of materials including metal
10. cedure requires that the operator knows the sound velocity of the material to be measured A table of common materials and their sound velocities can be found in Appendix A of this manual 1 Press the key to activate the calibration mode The MM or IN symbol should begin flashing Press the key again so that The M S or IN u S symbols are flashing Use the key and the key to adjust the sound velocity value up or down until it matches the sound velocity of the material to be measured You can also press the key to switch among the preset commonly using velocities Press the key to exit from the calibration mode The gauge is now ready to perform measurements To achieve the most accurate measurements possible it is generally advisable to always calibrate the gauge to a 17 sample piece of known thickness Material composition and thus its sound velocity sometimes varies from lot to lot and from manufacturer to manufacturer Calibration to a sample of known thickness will ensure that the gauge is set as closely as possible to the sound velocity of the material to be measured 4 3 3 Two Point Calibration Note This procedure requires that the operator has two known thickness points on the test piece that are representative of the range to be measured 1 Perform a Probe Zero 2 Apply couplant to the sample piece 3 Press the transducer against the sample piece at the first second calibration point making sure
11. e transducer is removed from the material being scanned the gauge will display the smallest measurement it found When the scan mode is turned off the single point mode will be automatically turned on Turn on off the scan mode by the following steps Press the key to switch the scan measurement mode on and off It will display the current condition of the scan mode on the main screen 4 6 Changing Resolution MT160 has selectable display resolution which is 0 1mm and 0 0i1mm This function is not available for MT150 which is fixed to 0 1mm Press down the key while turning on the gauge will switch the resolution between High and Low 21 4 7 Changing Units On the measurement mode press the key to switch back and forth between imperial and metric units 4 8 Memory Management 4 8 1 Storing a reading There are twenty files FOO F19 that can be used to store the measurement values inside the gauge At most 100 records thickness values can be stored to each file By simply pressing the key after a new measurement reading appears the measured thickness value will be saved to current file It is added as the last record of the file To change the destination file to store the measured values follow the steps 1 Press the key to activate the data logging functions It will display the current file name and the total record count of the file 2 Use the key and the key to select the desired file to
12. erform a measurement through this couplant film resulting in a measurement that is larger or smaller than it should be This phenomenon is obvious when one thickness value is observed while the transducer is in place and another value is observed after the transducer is removed In addition measurements through very thick paint or coatings may result in the paint or coating being measured rather than the actual material intended The responsibility for proper use of the instrument and recognition of these types of phenomenon rests solely with the user of the instrument 4 5 Scan mode While the gauge excels at making single point measurements it is sometimes desirable to examine a larger region searching for the thinnest point The gauge 20 includes a feature called Scan Mode which allows it to do just that In normal operation the gauge performs and displays four measurements every second which is quite adequate for single measurements In Scan Mode however the gauge performs ten measurements every second and displays the readings while scanning While the transducer is in contact with the material being measured the gauge is keeping track of the lowest measurement it finds The transducer may be scrubbed across a surface and any brief interruptions in the signal will be ignored When the transducer loses contact with the surface for more than two seconds the gauge will display the smallest measurement it found When th
13. eseseessssesseeeessessesee 25 4 14 System Reset ec ccccccereceeeeeeeeeceeeeeees 25 4 15 Connecting to a Computer eee 25 BS SI VICING secre iad las corer Dusit a A 26 6 Transport and Storage a0 ki oese renesse seee 26 Appendix A Sound VelocitieS cc ccccessecseeeerteees 27 Appendix B Applications Notes cceceecerees 28 1 Overview The model MT150 MT160 is a digital ultrasonic thickness gauge Based on the same operating principles as SONAR the instrument is capable of measuring the thickness of various materials with accuracy as high as 0 1 0 01 millimeters It is suitable for a variety of metallic and non metallic materials 1 1 Product Specifications 1 kW PD ol Display 4 5 digits LCD with EL backlight Measuring Rangel 0 750 300 mm in Steel Sound Velocity Range 1000 9999 m s Resolution MT150 0 1mm MT160 0 1mm 0 01mm Accuracy 0 0 5 Thickness 0 04 mm depends on materials and conditions Units Metric Imperial unit selectable Four measurements readings per second for single point measurement and ten per second for Scan Mode Memory for up to 20 files up to 99 values for each file of stored values Power Source Two AA size 1 5 Volt alkaline batteries 100 hours typical operating time EL backlight off 10 Communication RS232 serial port for MT160 No communication port for MT150 11 Outline dimensions 150mmx74mmx32 mm
14. he ultrasound emitter in the transducer A large emitting area will send more energy into the material being measured than a small emitting area Thus a so called 1 2 inch transducer will emit a stronger signal than a 1 4 inch transducer Absorption and Scattering As ultrasound travels through any material it is partly absorbed If the material through which the sound travels has any grain structure the sound waves will experience scattering Both of these effects reduce the strength of the waves and thus the 9 gauge s ability to detect the returning echo Higher frequency ultrasound is absorbed and scattered more than ultrasound of a lower frequency While it may seem that using a lower frequency transducer might be better in every instance low frequencies are less directional than high frequencies Thus a higher frequency transducer would be a better choice for detecting the exact location of small pits or flaws in the material being measured Geometry of the transducer The physical constraints of the measuring environment sometimes determine a transducer s suitability for a given job Some transducers may simply be too large to be used in tightly confined areas Also the surface area available for contacting with the transducer may be limited requiring the use of a transducer with a small wearface Measuring on a curved surface such as an engine cylinder wall may require the use of a transducer with a matching c
15. icular at right angle to the long axis of the pipe For smaller pipe diameters two measurements should be performed one with the wearface gap perpendicular another with the gap parallel to the long axis of the pipe The smaller of the two displayed values should then be taken as the thickness at that point 28 Perpendicular Parallel Measuring hot surfaces The velocity of sound through a substance is dependant upon its temperature As materials heat up the velocity of sound through them decreases In most applications with surface temperatures less than about 100 C no special procedures must be observed At temperatures above this point the change in sound velocity of the material being measured starts to have a noticeable effect upon ultrasonic measurement At such elevated temperatures it is recommended that the user perform a calibration procedure on a sample piece of known thickness which is at or near the temperature of the material to be measured This will allow the gauge to correctly calculate the velocity of sound through the hot material When performing measurements on hot surfaces it may also be necessary to use a specially constructed high temperature transducer These transducers are built using materials which can withstand high temperatures Even so it is recommended that the probe be left in contact with the surface for as short a time as needed to acquire a stable measurement While the transducer is in cont
16. neven surfaces may limit the penetration of ultrasound through the material and result in unstable and therefore unreliable measurements The surface being measured should be clean and free of any small particulate matter rust or scale The presence of such obstructions will prevent the transducer from seating properly against the surface Often a wire brush or scraper will be helpful in cleaning surfaces In more extreme cases rotary sanders or grinding wheels may be used though care must be taken to prevent surface gouging which will inhibit proper transducer coupling Extremely rough surfaces such as the pebble like finish of some cast iron will prove most difficult to measure These kinds of surfaces act on the sound beam like frosted glass on light the beam becomes diffused and scattered in all directions In addition to posing obstacles to measurement rough surfaces contribute to excessive wear of the transducer particularly in situations where the transducer is scrubbed along the surface Transducers should be inspected on a regular basis for signs of uneven wear of the wearface If the wearface is worn on one side more than another the sound beam penetrating the test material may no longer be perpendicular to the material surface In this case it will be difficult to exactly locate tiny irregularities in the material being measured as the focus of the sound beam no longer 13 lies directly beneath the transducer
17. ng prior to calibration will result in a multi material velocity calculation that may be different from the actual material velocity intended to be measured 4 3 1 Calibration to a known thickness Note This procedure requires a sample piece of the specific material to be measured the exact thickness of which is known e g from having been measured by some other means 1 Perform a Probe Zero 2 Apply couplant to the sample piece 3 Press the transducer against the sample piece making sure that the transducer sits flat against the surface of the sample The display should show some thickness value and the coupling status indicator should appear steadily 4 Having achieved a stable reading remove the transducer If the displayed thickness changes from the value shown while the transducer was coupled repeat step 3 5 Press the key to activate the calibration mode The MM or IN symbol should begin flashing 16 Use the key and the key to adjust the displayed thickness up or down until it matches the thickness of the sample piece Press the key again The M S or IN u S symbols should begin flashing The gauge is now displaying the sound velocity value it has calculated based on the thickness value that was entered Press the key once again to exit the calibration mode and return to the measurement mode The gauge is now ready to perform measurements 4 3 2 Calibration to a known velocity Note This pro
18. other abnormal phenomena please do not dismantle or adjust any fixedly assembled parts Fill in and present the warranty card to us The warranty service can be carried on 6 Transport and Storage 1 Keep it away from vibration strong magnetic field corrosive medium dumpiness and dust Storage in ordinary temperature 2 With original packing transport is allowed on the third grade highway 26 Appendix A Sound Velocities Material Sound Velocity in us m s Aluminum 0 250 6340 6400 Steel common 0 233 5920 Steel stainless 0 226 5740 Brass 0 173 4399 Copper 0 186 4720 Iron 0 233 5930 Cast Iron 0 173 0 229 44000 5820 Lead 0 094 2400 Nylon 0 105 2680 Silver 0 142 3607 Gold 0 128 3251 Zinc 0 164 4170 Titanium 0 236 5990 Tin 0 117 2960 Epoxy resin 0 100 2540 Ice 0 157 3988 Nickel 0 222 5639 Plexiglass 0 106 2692 27 Polystyrene 0 092 2337 Porcelain 0 230 5842 PVC 0 094 2388 Quartz glass 0 222 5639 Rubber vulcanized 0 091 2311 Teflon 0 056 1422 Water 0 058 1473 Appendix B Applications Notes Measuring pipe and tubing When measuring a piece of pipe to determine the thickness of the pipe wall orientation of the transducers is important If the diameter of the pipe is larger than approximately 4 inches measurements should be made with the transducer oriented so that the gap in the wearface is perpend
19. ransducer into the material and back again Before attempting to make a measurement a small amount of couplant should be applied to the surface of the material being measured Typically a single droplet of couplant is sufficient After applying couplant press the transducer wearface down firmly against the area to be measured The coupling status indicator should appear and a digit number should appear in the display If the instrument has been properly zeroed and set to the correct sound velocity the number in the display will indicate the actual thickness of the material directly beneath the transducer If the coupling status indicator does not appear not 19 stable or the numbers on the display seem erratic firstly check to make sure that there is an adequate film of couplant beneath the transducer and that the transducer is seated flat against the material If the condition persists it may be necessary to select a different transducer size or frequency for the material being measured While the transducer is in contact with the material that is being measured the instrument will perform four measurements every second updating its display as it does so When the transducer is removed from the surface the display will hold the last measurement made Note Occasionally a small film of couplant will be drawn out between the transducer and the surface as the transducer is removed When this happens the gauge may p
20. s plastics and glass Materials that are difficult include some cast materials concrete wood fiberglass and some rubber 30 Couplants All ultrasonic applications require some medium to couple the sound from the transducer to the test piece Typically a high viscosity liquid is used as the medium The sound used in ultrasonic thickness measurement does not travel through air efficiently A wide variety of couplant materials may be used in ultrasonic gauging Propylene glycol is suitable for most applications In difficult applications where maximum transfer of sound energy is required glycerin is recommended However on some metals glycerin can promote corrosion by means of water absorption and thus may be undesirable Other suitable couplants for measurements at normal temperatures may include water various oils and greases gels and silicone fluids Measurements at elevated temperatures will require specially formulated high temperature couplants Inherent in ultrasonic thickness measurement is the possibility that the instrument will use the second rather than the first echo from the back surface of the material being measured while in standard pulse echo mode This may result in a thickness reading that is TWICE what it should be The Responsibility for proper use of the instrument and recognition of these types of phenomenon rests solely with the user of the instrument 31
21. set as current file 3 Press the key to exit the data logging functions at any time 4 8 2 Clearing selected file The user may require the contents of an entire file be completely cleared of all measurements This would allow the user to start a new list of measurements starting at storage location LOO The procedure is outlined in the following steps 22 Press the key to activate the data logging fuctions It will display the current file name and the total record count of the file Use the key and the key to scroll to the file that will be cleared of all measurements Press the key on the desired file It will automatically clear the file and display DEL Press the key at any time to exit the data logging functions and return to measurement mode 4 8 3 Viewing deleting stored record This function provides the user with the ability to view delete a record in a desired file previously saved in memory Following is the steps 1 Press the key to activate the data logging functions It will display the current file name and the total record count of the file Use the key and the key to select the desired file Press the key to enter the selected file It will display the current record number for example L012 and the record content Use the key and the key to select the desired record Press the key on the desired record It will automatically delete this record and display DEL
22. test piece vO Sound Velocity in the material tO The measured round trip transit time 1 4 Configuration Table 1 1 Standard 1 Main body 7 Configur Transducer EE 3 Coupan tT 4 Instrument Case 1 5_ OperatingManual 14 6 Alkaline battery 2 AAsize eee eee few E oe Optional Transducer N02 _ See Configur Transducer NO7 _ Table3 1 ation Transducer HT5 Mini thermal Only for printer MT160 Communication 1 Cable 1 5 Operating Conditions Operating Temperature 20 C 60 C Storage Temperature 30 C O 70 C Relative Humidity lt 900 Qj The surrounding environment should avoid of vibration strong magnetic field corrosive medium and heavy dust 2 Structure Feature ULTRASONIC THICKNESS GAUGE POWER 2X1 5V 1 The main body 2 Keypad 3 LCD display 4 Pulser socket 5 Receiver socket 6 Probe zero disc 7 Communication port 8Label 9 Battery cover 10 Probe 2 1 Main Screen a INMM iS fan MOC LALO 1 Coupling Status Indicate the coupling status While the gauge is taking a measurement the coupling status should be on If it is not on or not stable the gauge is having difficulty achieving a stable measurement and the thickness value displayed will most likely be erroneous 2 Unit Current unit system MM or IN for thickness value M S or IN u S for sound velocity 3 Battery Information Display the rest capacity of
23. ulated its internal error factor and will compensate for this value in any subsequent measurements When performing a probe zero the instrument will always use the sound velocity value of the built in probe disc even if some other velocity value has been entered for making actual measurements Though the instrument will remember the last probe zero performed it is generally a good idea to perform a probe zero whenever the gauge is turned on as well as any time a different transducer is used This will ensure that the instrument is always correctly zeroed Press while in probe zero mode will stop current probe zero operation and return to the measurement mode 4 3 Sound Velocity Calibration In order for the gauge to make accurate measurements it must be set to the correct sound velocity for the material being measured Different types of material have different inherent sound velocities If the gauge is not set to the correct sound velocity all of the measurements the gauge makes will be erroneous by some fixed percentage The 15 One Point calibration is the simplest and most commonly used calibration procedure optimizing linearity over large ranges The Two point calibration allows for greater accuracy over small ranges by calculating the probe zero and velocity Note One and Two point calibrations must be performed on material with the paint or coating removed Failure to remove the paint or coati
24. urved wearface Temperature of the material When it is necessary to measure on surfaces that are exceedingly hot high temperature transducers must be used These transducers are built using special materials and techniques that allow them to withstand high temperatures without damage Additionally care must be taken when performing a Probe Zero or Calibration to Known Thickness with a high temperature transducer Selection of the proper transducer is often a matter of tradeoffs between various characteristics It may be necessary to experiment with a variety of transducers in order to find one that works well for a given job 10 The transducer is the business end of the instrument It transmits and receives ultrasonic sound waves that the instrument uses to calculate the thickness of the material being measured The transducer connects to the instrument via the attached cable and two coaxial connectors When using transducers the orientation of the dual coaxial connectors is not critical either plug may be fitted to either socket in the instrument The transducer must be used correctly in order for the instrument to produce accurate reliable measurements Below is a short description of the transducer followed by instructions for its use j Left figure is a bottom view of a typical transducer The two semicircles of the wearface are visible as is the barrier separating them One of the semicircles is