telemetry measurement of selected biological signals by
Contents
1. 229 Telemetry measurement of selected biological signals TELEMETRY MEASUREMENT OF SELECTED BIOLOGICAL SIGNALS BY USING BLUETOOTH TECHNOLOGY M Cerny M Penhaker VSB Technical university of Ostrava Faculty of electrical engineering and computer science Department of measurement and control 17 listopadu 15 708 33 Ostrava Poruba Czech republic E mail martinblack centrum cz P VSB Technical university of Ostrava Faculty of electrical engineering and computer science Department of measurement and control 17 listopadu 15 708 33 Ostrava Poruba Czech republic E mail marek penhaker vsb cz Summary This work treats of using the Bluetooth technology in biomedical engineering The Bluetooth is used for transmission of measured data from pulse oximeter ECG and monitor of blood pressure OEM modules realize the devices for pulse oximetry and ECG Both these realized devices can communicate with computer by Bluetooth technology and standard serial link too The realized system of measuring devices is very flexible and mobile because the Bluetooth technology is used and accumulators can supply the realized devices It is possible to measure other physical values converted to voltage because the used OEM module for pulse oximetry include A D converter The part of this work is software visualisation of measured values too Abstrakt Tato pr ce se zab v mo nost vyu it technologie Bluetooth v oblastech telemedic ny a
2. ation and cases The module automatically forms a wireless multidrop network and distributes all data to all connected devices Dalgalan 5 Fig 4 Used Bluetooth module 3 TREATMENT The first was tested communication between referenced devices and computer by standard serial line It was good for test of functionality of devices and ability of communication Then can be designed realized and tested Bluetooth communication The first it was point to point communication afterwards the point to multipoint communication It was created wireless network of all referenced devices It is necessary to set up correct communication protocol of serial communication between device computer and Bluetooth module the first Afterwards could be set up the parameters of Bluetooth communication 231 At the basic settings were set up name of Bluetooth device and selected possibility to set up the Bluetooth parameters by Bluetooth Next was selected operation mode connectable and discoverable The other devices can connect to it andit can be found when other devices are performing searches It was necessary to decide on aclient or a server role of Bluetooth module Used Bluetooth modules can be set up client and the server at the same time It is very profitable at point to point communication For point to point communication were designed three versions of Bluetooth communications parameters Referenced Bluetooth modules at the comput
3. biomedic nsk ho in en rstv Pro p enos hodnot nam en ch pulsn m oxymetrem elektrokardiogramem a monitorem krevn ho tlaku je vyu ito technologie Bluetooth Za zen pro sn m n pulsn oxymetrie a elektrokardigramu jsou z d vodu po adavku co nejmen ch rozm r realizov ny pomoc OEM modul kter se u vaj v modern l ka sk technice Oba tyto vytvo en p stroje nab z mo nost komunikace s po ta em jak po standardn seriov lince tak pomoc Bluetooth Oba vytvo en p stroje lze rovn nap jet pomoc akumul tor Realizovan syst m m c ch za zen je d ky technologii Bluetooth a mo nosti nap jen akumul tory velice flexibiln Sou st OEM modulu pro pulsn oxymetrii je A D p evodn k T m je umo n no m it dal fyzik ln veli iny p eveden na nap t jako je nap klad teplota Sou st pr ce je tak zpracov n a vizualizace nam en ch dat 1 INTRODUCTION 2 MATERIALS AND METHODS It was used OEM modules from refurbished produces for measure Such OEM modules are often included in many diagnostics devices Because such OEM modules are created for using at built in systems it was necessary to solve problems with power supply and optimize communication interface to can those OEM modules communicate with computer by standard serial interface or by Bluetooth There was for both selected OEM modules designed and realized circuits for power supply
4. de standard serial interface This interface was used for Bluetooth communication too The Bluetooth module was connected to that interface It was necessary to connect Bluetooth module to serial connector and provide power supply The blood pressure monitor can save measured values from last 126 measurements It is saving these four basic values systolic pressure diastolic pressure pulse frequency and time It is possible to start a new measuring by defined command from connected computer too In this case the monitor sends to computer measured values immediately after end of measuring process 230 Fig 3 Blood pressure monitor Bluetooth module which was chosen for realisation Bluetooth communication can be used as acomponent in many types of systems allowing them to communicate wirelessly with other Bluetooth products such as PC cards laptops handheld computers and mobile phones It allows with an RS232 port or UART interface to communicate wirelessly via Bluetooth with other Bluetooth devices The module can be configured using the Windows based configuration wizard or using AT commands It supports Generic access profile Serial port profile Dial up profile and LAN access profile The module is qualified according to the Bluetooth 1 1 specification Next function of this module is Wireless multidrop This feature allows the module to simultaneously communicate with up to three remote Bluetooth devices depending on applic
5. er and device side realized the Bluetooth communication too Be Fig 5 Point to point communication For point to multipoint communication was possible to use on computer side USB Bluetooth dongle orreferenced Bluetooth module and its function for creating point to multipoint network Wireless multidrop But after tests it was clear that this function Wireless multidrop isn t accordant with engaged wants As a consequence was chosen USB Bluetooth dongle BT 600 from ACER Company This USB dongle can work by standard driver for Bluetooth communications included in operating system WindowsXP 2nd service pack This driver provides to create more than one virtual serial port The first was tested point to point communication between computer with USB Bluetooth dongle and measuring devices via Bluetooth Afterwards was designed and realized point to multipoint connection between referenced USB Bluetooth dongle and all other referenced devices After the far devices with Bluetooth module were found by the USB Bluetooth dongle more precisely by drivers in operating system were these devices added to list of Bluetooth devices Each of found devices gets own virtual serial port In the visualisation software which was created too was set up only correct name of virtual serial port for each device and communication could start Telemetry measurement of selected biological signals Fig 6 Point to multipoint communicat
6. ion Part of this work is the software for visualisation and saving measured data too This software named BIOMONITOR is developed in development system Labview from National instruments version 6 1 The most important demands were easy intuitive control and very good lucidity of user interface It was designed and realized user interface where each group of measured values has own colour of chart or more precisely colour of background The part of final software is the Terminal too Terminal allows to user select which values would to measure at that time Depending on it the user interface is changed and user can see only that charts and groups of indicators which are need to indicate measured data Fig 7 BIOMONITOR user interface Displayed version of software is suited for visualisation values which are measured in frame of project of Biomedical laboratory VSB TU Ostrava Biotelemetry system of pilot for Shell Eco Marathon Advances in Electrical and Electronic Engineering 4 RESULTS It was realized wireless network of medical devices The network was realized by Bluetooth technology For Bluetooth communication was used Bluetooth modules created for serial cable replacement on the device side On the computer side was used USB Bluetooth dongle All the system is mobile and can be used in every computer which can cooperate with USB Bluetooth dongle It can be used incomputer which include anything else fo
7. r realize Bluetooth communication Accumulators can supply realized devices It is very good because such devices are flexible and mobile It was created software for visualisation and Saving measured data Software is very easy to control and it is very well designed Software displays all the measured data at the time The values measured at the analog inputs of ChipOx module are displayed and saved too 5 CONCLUSIONS The results of this work can be used inimplementation of wireless communication in branch of medical technique Realized network of devices can be used in many applications of telemedicine mainly as the system of monitoring base life functions This network can be used in the field of telemonitoring for example long ill people elderly people and other 232 REFERENCES 1 User manual Digital Pulse Oximeter Module ChipOx Wismar N mecko EnviteC Wismar GmbH 2004 36 s 2 Documnetation for OEM ECG board Karlsruhe N mecko MCC GmgH amp Co KG 2002 10 s 3 OEM Serial Port Adapter 2 Generation Electrical amp Mechanical Datasheet verze 1 5 Malm Sv dsko connectBlue AB 2003 44 s 4 OEM Serial Port Adapter 2 Generation User manual 2 11 Malm v dsko connectBlue AB 2003 48 s 5 Penhaker M Imramovsky M Tiefenbach P Kobza F L karsk diagnostick pristroje u ebn texty Ostrava 2004 ISBN 80 248 0751
8. stabilization circuits for The Bluetooth is one of the modern telecommunication technologies which is used in many branches so often now This young and dynamically developed technology is used in many applications which we are using every day Itis used in mobile telecommunications for wireless connection of computer peripheries for wireless connections of various sensors and regulators in industry regulations So why don t to use this technology in biomedical engineering This work treats of usage the Bluetooth technology in biomedical engineering The Bluetooth technology is used for wireless transmission of some biological signals from measuring device to computer Measuring devices including Bluetooth could be more mobile the manipulation with these devices could be easier and there couldn t be emplacement problems To check on possibility of usage of Bluetooth technology in biomedical engineering it was used for transmission data from blood pressure monitor from device for pulse oximetry and ECG data Cable replacement is benefit for user User get more comfort the manipulation with device is easier The device is more flexible and more useable There is the possibility to create wireless network set up from more devices It is possible to communicate with notebooks PDA or mobile phones conversion communication interface of modules to RS232 standard and circuits which allow connections with modules for realize Bluetoo
9. th connections The first chose OEM module is OEM module named ChipOx from EnviteC Company ChipOx is a pulse oximeter module for the non invasive determination of the functional oxygen saturation in human arterial blood SpO2 and for measuring the pulse frequency ChipOx has very small dimensions 31mm x 14mm x 5mm which allows it to be easily installed in medical products It also has low energy consumption is equipped with ESD and EMC protection and can be easily mounted on a carrier printed circuit board host PCB Advances in Electrical and Electronic Engineering ChipOx offers 3 inputs with maximal input voltage 2400 mV for the measurement of other parameters which are each sampled with a maximum of 100 Hz 12 Bits The sampling rate and the input voltage ranges are freely configurable over the communication protocol Fig 1 Realized pulse oximeter The second chose OEM module is module ECG 100 from MCC Company It is created for electrocardiography with standard bipolar limbs leads It can communicate by UART protocol It sends to host device values of II and III Einthoven leads Measured pulse frequency range is between 30 and 245 beats per second and it is measured as sliding average from last eight measured values Module can detect pacemaker impulses and when leads are not connected Bluetooth module Fig 2 Realized ECG For blood pressure measuring was used blood pressure monitor UA 767PC which inclu
Download Pdf Manuals
Related Search
Related Contents
Seiko Smart Label 240 Thermal Printer - Seiko%20Models%20SLP%20100%20SLP%20200%20%26%20SLP%20240%20User%20Manual Cypress CY8C23533 User's Manual Note - ADAS-EU M24LR64-R tool kit user guide 学校通信27.10.22(16号) Helios 7TM - Titan Controls WT3000-I-Plus - Primax Balanças 電温ユプロ<フルオート> Kettler 01491-000 User's Manual Copyright © All rights reserved.