Contents
1. 3 If an object s surface is highly reflective apply masking tape or flat black paint to the surface before measuring The meter may not make accurate measurements through transparent surfaces such as glass 5 Steam dust smoke etc can obscure measurements 6 To find a hot spot aim the meter outside the area of interest then scan across in an up and down motion until the hot spot is located 8 EX850 EN V2 1 4 14 EXTECH INSTRUMENTS Data Hold To freeze the LCD reading press the HOLD button While data hold is active the HOLD icon appears on the LCD Press the HOLD button again to return to normal operation Peak Hold The Peak Hold function captures the peak AC or DC voltage or current The meter can capture negative or positive peaks as fast as 1 millisecond in duration 1 Turn the function switch to the A or V position 2 Use the MODE button to select AC or DC 3 Allow time for the display to stabilize 4 Press and Hold the PEAK button until CAL appears in the display This procedure will zero the range selected o Press the PEAK button Pmax will display 6 The display will update each time a higher positive peak occurs 7 Press the PEAK button again Pmin will display The display will now update and indicate the lowest negative peak 8 To return to normal operation press and hold the PEAK button until the Pmin or Pmax indicator switches off Note If the Function switch position is changed after a
2. If the meter is not to be used for 60 days or more remove the battery and store it separately Battery Replacement 1 Remove the Phillips head screw that secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the battery compartment 12 EX850 EN V2 1 4 14 EXTECH INSTRUMENTS Specifications Function Range amp Resolution Accuracy of reading digits AC Current 400 0 AAC 2 5 8d 50 60 Hz 1000 AAC 2 8 5d 400 0 ADC 2 5 5d 1000 ADC 2 8 5d AC Voltage 4 000 VAC 50 60Hz 40 00 VAC 1 5 5d 400 0 VAC F205 400 0 mVDC 0 8 2d 4 000 VDC DC Voltage 40 00 VDC 1 5 2d 400 0 VDC DC Current 400 00 1 0 4d 4 000kQ 40 000kQ 1 5 2d Resistance 400 0kQ 4 000MQ 2 5 3d 40 00MQ 3 5 5d 4 000nF 5 0 30d 40 00nF 5 0 20d 400 0nF Capacitance 4 000uF 3 0 5d 40 00uF 400 0uF 4 0 10d 4 000mF 10 10d 4 000kHz 1 5 2d Frequency Sensitivity 100V lt 50Hz 50V 50 to 400Hz 5V 401Hz to 4000Hz 13 EX850 EN V2 1 4 14 Function Range and Resolution Temperature type K EXTECH INSTRUMENTS Accuracy of reading digits 3 rdg 9 F 4 to 1400 F 20 to 760 C 3 rdg 5 C 2 0 reading or 4 F whichever is gt 4 to 518 F 20 to 270 C Clamp jaw opening Display Continuity check Diode test Low Battery indicati
3. calibration the Peak Hold calibration must be repeated for the new function selected MAX MIN 1 Press the MAX MIN key to activate the MAX MIN recording mode The display icon MAX will appear The meter will display and hold the maximum reading and will update only when a new max occurs 2 Press the MAX MIN key and the display icon MIN will appear The meter will display and hold the minimum reading and will update only when a new min occurs 3 Press the MAX MIN key and a blinking MAX MIN will appear The meter will display the present reading but will continue to update and store the max and min readings 4 To exit MAX MIN mode press and hold the MAX MIN key for 2 seconds pee pe Units Switch Temperature Units F C ee The temperature unit selection switch is located in the battery NY e compartment To change the units remove the battery door lift out the battery and set the switch for the desired units w LCD Backlight Button The LCD is equipped with backlighting for easier viewing especially in dimly lit areas Press the backlight button to turn the backlight on Press again to turn the backlight off 9 EX850 EN V2 1 4 14 EXTECH INSTRUMENTS Automatic Power OFF In order to conserve battery life the meter will automatically turn off after approximately 10 minutes To turn the meter on again turn the function switch to the OFF position and then to the desired fun
4. 9 Washington Street Melrose MA 02176 TestEquipmentDepot com
5. ENTS FCC COMPLIANCE FCC ID IWK EX850 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy harmful interference to radio communications However there is no guarantee that interference will not occur ina particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help A CAUTION Exposure to Radio Frequency Radiation To comply with FCC IC RF exposure compliance requirements a separation distance of at least 20 cm mu
6. EXTECH USER GUIDE INSTRUMENTS Extech EX850 True RMS 1000 Amp Clamp Meter Bluetooth and Android ready Patented CE Test Equipment 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 va n see intesee EXTECH INSTRUMENTS Introduction Congratulations on your purchase of the Extech EX850 CAT IV True RMS 1000A Clamp Meter This meter includes a Bluetooth module and is Android ready The EX850 measurement functions include AC DC Voltage AC DC Current Resistance Capacitance Frequency Duty Cycle Diode Test Continuity Type k thermocouple thermometer plus Non Contact IR Temperature Proper use and care of this meter will provide many years of reliable service Visit www extech com for more information Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information A This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present im Double insulation SAFETY NOTES e Do not exceed the maximum allowable input range of any function e Do not apply voltage to meter when resistance function is selected e Set the function switch OFF when the meter is not in use e Remove the battery if meter is to be stored for longer than 60 days WARNINGS e Set function switch to the appropriate position before measurin
7. MP jacks observing polarity Touch the Temperature Probe tip to the device under test Continue to touch the part under test with the probe until the reading stabilizes Read the temperature on the display The digital reading will indicate the proper decimal point and value 250 C 4 to 482 F Continuity Measurements 1 Insert the black test lead into the negative COM terminal and the red test lead into the Q positive terminal 2 Set the function switch to the e position 3 Use the MODE button to select continuity e The display icons will change when the MODE button is pressed 4 Touch the test probe tips across the circuit or component under test 5 Ifthe resistance is lt 40 Q a tone will sound Diode Test 1 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the PF positive jack 2 Turn the function switch to PF position Use the MODE button to select the diode function if necessary diode symbol will appear on the LCD when in Diode test mode 3 Touch the test probe tips to the diode or semiconductor junction under test Note the meter reading 4 Reverse the test lead polarity by reversing the red and black leads Note this reading 5 The diode or junction can be evaluated as follows If one reading displays a value typically 0 400V to 0 900V and the other reading displays OL the diode is good If both readings display OL the device is ope
8. ay capacitance Touch the test probe tips across the part under test Read the capacitance value in the display The display will indicate the proper decimal point and value Note For very large values of capacitance measurement time can be several minutes before the final reading stabilizes Frequency Measurements 1 2 Set the function switch to the V Hz Position Press and hold the MODE button to select the Frequency Hz function k Hz will appear in the display Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the Hz positive jack Touch the test probe tips across the part under test Read the Frequency value on the display The display will indicate the proper decimal point and value Press and hold the MODE button again to return to the voltage mode 6 EX850 EN V2 1 4 114 EXTECH INSTRUMENTS Type K Temperature Measurements 1 2 WARNING To avoid electric shock be sure the thermocouple probe has been removed before changing to another measurement function Note Open inputs or temperature over ranges cause OL display and beep Note See the Temperature Units paragraph to select F or C Note The temperature range of the supplied thermocouple probe is 20 to Set the function switch to the K Temp position Insert the Temperature Probe into the negative COM and the positive TE
9. ction position Bluetooth Communication The meter includes a Bluetooth module Enable the EX850 Bluetooth by pressing and holding the side Bluetooth SEND Backlight button for two seconds On the second beep the Bluetooth icon will appear in the display Android Applications The EX850 meter is Android ready Follow the steps below to obtain the Android application ExView EX850 and to connect to the meter with an Android device 1 Obtain and install the Android ExView EX850 application from the Google Play Store 2 Perform a search to obtain the EX850 from the list of available devices 3 Pair the meter with the Android device pad tablet phone etc in Settings under Bluetooth 4 Start the ExView EX850 application tap CONNECT and the paired list will appear Select the EX850 meter from the paired list gi The meter will begin communicating and Meter readings will appear on the Android device 6 The user can select the meter s measurement mode directly from the icons shown on the bottom row of the Android device V A mA A etc Simply tap the desired measurement parameter to view the readings Refer to the screen shots below Note If several meters are to be used be sure to note the unique address of each meter to quickly discern which meter is displaying at any given time Android Application Screen Shot Examples AC CURRENT AC Current 29 9 AC Voltage 10 EX850 EN V2 1 4 14 EXTECH INSTRUM
10. g e When measuring volts do not switch to current resistance modes e Do not measure current on a circuit whose voltage exceeds 600V e When changing ranges always disconnect the test leads from the circuit under test Maximum Input A AC ADC 1000A DC AC V DC V AC 1000V DC AC Resistance Capacitance Frequency Diode Test 250V DC AC Type K Temperature 60V DC 24V AC 2 EX850 EN V2 1 4 14 EXTECH INSTRUMENTS CAUTIONS e Improper use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter e Always remove the test leads before replacing the battery or fuses e Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use e Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC These voltages are considered a shock hazard e Always discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests e Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts Other means should be used to ensure that the terminals are not live e If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired e This device is not a toy and must not reach c
11. hildren s hands It contains hazardous objects as well as small parts that the children could swallow In case a child swallows any of them please contact a physician immediately e Do not leave batteries and packing material lying around unattended they can be dangerous for children if they use them as toys e Incase the device is going to be unused for an extended period of time remove the batteries to prevent them from draining e Expired or damaged batteries can cause cauterization on contact with the skin Always therefore use suitable hand gloves in such cases e See that the batteries are not short circuited Do not throw batteries into the fire e Do not directly view or direct the laser pointer at an eye Low power visible lasers do not normally present a hazard but may present some potential for hazard if viewed directly for extended periods of time 3 EX850 EN V2 1 4 14 Desc ription EXTECH INSTRUMENTS Meter Description 1 SOP OO OG ee PPrRPPR DoW N B O Current clamp Clamp opening trigger Data Hold Button Mode Peak Range DCA Zero MIN MAX Backlit LCD Display Test lead input jacks IR thermometer and laser pointer rear Bluetooth SEND Backlight Button Laser pointer button Function switch Display icons Description HOLD Data Hold Minus sign Negative reading display 0 to 3999 Measurement display digits ZERO Zero P Peak value AUTO Auto Range mode DC AC Direct Alternati
12. n If both readings are very small or 0 the device is shorted 7 EX850 EN V2 1 4 14 EXTECH INSTRUMENTS 5 Read the temperature in the display J e DATER orien he Note See the Temperature Units paragraph to select F or C AAOC CLASS Il LASER PRODUCT Non Contact InfraRed Temperature Measurements 1 Set the function switch to the IR Temp position 2 Aim the infrared sensor rear of the meter at the surface to be measured 3 Press the button in the center of the rotary function switch to turn on the laser pointer and identify the surface spot to be measured 4 The area of the surface to be measured must be larger than the spot size as determined by the distance to spot size specification WARNING Do not directly view or direct the laser pointer at an eye Low power visible lasers do not normally present a hazard but may present some potential for hazard if viewed directly for extended periods of time IR Spot to Distance Diagram The 8 1 spot to distance ratio determines the size of the measured surface area with respect to the distance the meter is held away from the surface Diameter of spot 60cm gt Distance to object IR Measurement Notes 1 The object under test should be larger than the spot target size calculated by the field of view diagram 2 If the surface of the object under test is covered with frost oil grime etc clean before taking measurements
13. ng Current MAX Max reading MIN Min reading ch Low battery mV or V Milli volts or Volts Voltage Q Ohms Resistance A Amperes Current F Farad Capacitance Hz Hertz Frequency F and C Fahrenheit and Celsius units Temperature IR TEMP MAX MIN Pmax Pun AUTO HOLD ZERO npmF Mk Hz 5000 ou pa a a Fe n m u M k Unit of measure prefixes nano milli micro mega and kilo Continuity test Diode test Laser pointer Bluetooth active symbol EX850 EN V2 1 4 14 EXTECH INSTRUMENTS Operation NOTES Read and understand all Warning and Caution statements in this operation manual prior to using this meter Set the function select switch to the OFF position when the meter is not in use AC Current Measurements WARNING Ensure that the test leads are disconnected from the meter before making current clamp measurements 1 Set the Function switch to the AAC or ADC range 2 Press the trigger to open the jaw Fully enclose only one conductor For optimum results center the conductor in the jaw 3 The clamp meter LCD will display the reading DCA ZERO The DC Zero feature removes offset values and improves accuracy for DC current measurements To perform a zero select ADC and with no conductor in the jaw Correct Incorrect 1 Press the DC ZERO button to zero the display ZERO will appear in the display The offset value is now st
14. on Over range indication Measurement rate Bluetooth range PEAK Thermocouple sensor IR Spectral response IR Emissivity IR distance ratio Input Impedance AC bandwidth AC response Crest Factor Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Battery Auto power OFF Dimensions amp Weight Safety Patent notice 2 0 reading or 2 C whichever is gt 1 7 43mm approx 3 3 4 digits 4000 counts backlit LCD Threshold 40Q Test current lt 0 5mA Test current of 0 3mA typical Open circuit voltage lt 3VDC typical Battery symbol is displayed OL display 2 readings per second nominal 32 feet 10 meters approximately Captures peaks gt 1ms Type K thermocouple required 6 to 16um 0 95 fixed 8 1 10MQ VDC and VAC 50 to 400Hz AAC and VAC True rms AAC and VAC 3 0 in 40A and 400A ranges 1 4 in 1000A range 50 60Hz and 5 to 100 of range 41 F to 104 F 5 C to 40 C 4 F to 140 F 20 C to 60 C Max 80 up to 87 F 31 C decreasing linearly to 50 at 104 F 40 C lt 80 7000ft 2000meters maximum One 1 9V Battery NEDA 1604 After approx 10 minutes 10 6x4 3x2 270x110x50mm 13 6 0z 386g For indoor use and in accordance with the requirements for double insulation to IEC1010 1 2001 EN61010 1 2001 Overvoltage Category IV 600V and Category III 1000V Pollution Degree 2 U S Patent 7163336 Test Equipment Depot 800 517 8431 9
15. ored and remo ved from all measurements 2 To view the stored value press the DC ZERO button ZERO will flash and the stored value will be displayed 3 To exit this mode press and Hold the ZERO button until ZERO is no longer in the display AC DC Voltage Measurements 1 Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal Set the function switch to the VAC or VDC position Use the MODE button to select AC or DC Voltage Connect the test leads in parallel to the circuit under test WG ere Read the voltage measurement on the LCD display 5 EX850 EN V2 1 4 14 EXTECH INSTRUMENTS Resistance Measurements Note Remove power before making resistance measurements 12 Insert the black test lead into the negative COM terminal and the red test lead into the Q positive terminal Set the function switch to the Q position Touch the test probe tips across the circuit or component under test Read the resistance on the LCD display Capacitance Measurements WARNING To avoid electric shock discharge the capacitor under test before measuring If dISC appears in the display remove and discharge the capacitor Set the function switch to the 1 Q capacitance position Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the CAP positive jack Press MODE to zero any str
16. st be maintained between the antenna of this device and all persons This device must not be co located or operating in conjunction with any other antenna or transmitter A WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 11 EX850 EN V2 1 4 14 EXTECH INSTRUMENTS INDUSTRY CANADA IC COMPLIANCE IC ID 1590A EX850 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device A CAUTION Exposure to Radio Frequency Radiation To comply with RSS 102 RF exposure compliance requirements for mobile configurations a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons This device must not be collocated or operating in conjunction with any other antenna or transmitter Maintenance WARNING To avoid electrical shock disconnect the meter from any circuit remove the test leads from the input terminals and turn OFF the meter before opening the case Do not operate the meter with an open case Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent do not use abrasives or solvents