1. Master Station IP When Call Master by IP Address is set enter the IP address of the related 1 to 4 master station If set to zero uses broadcast to find a BARIX AG 47 91 master station on the local network The first master station is called after pressing the Button 1 activating the first digital input Default setting is 0 0 0 0 Call next Master If set to Yes the client is forced to call the next master in the list if the one that it is currently calling is not responding for example because of network problems or power failure of the master The call to the next master is activated after the expiry if the auto hang up timeout In this case the call ring timer is restarted when the client starts calling the next master Default No Auto Hang Up Configures the number of seconds after which the client will stop ringing if the master is not responding Minimum value allowed is 3 maximum is 60 Make sure this value is greater than the unattended mode timeout set for the ICMASTER otherwise the ICCLIENT will not get the unattended message from the ICMASTER Default 20 3 4 2 5 Background Music Background Music multiple channel service BGM works listening for one or more UDP audio streams on a range of ports Stream audio format expected must be as RTP MPEG BARIX AG 48 91 To enable the BGM service almost a starting port and a total number of channels must be supplied Onc
2. 8 1 3 8 1 4 DHCP FDX HDX Short for Dynamic Host Configuration Protocol a protocol used to assign an IP address to a device connected to a Network Short for Full Duplex A full duplex system allows communication between two parties to be done in both directions simultaneously See this Wikipedia article for more information Short for Half Duplex In a half duplex system simultaneous communication in both directions is not possible i e if one of the parties is sending the other have to wait it to finish before replying See this Wikipedia article for more information Short for Internet Protocol the IP is an address of a computer or other network device on a network using IP or TCP IP Every device on an IP based network requires an IP address to identify its location or address on the network Example 192 168 2 10 BARIX AG 83 91 8 1 5 IPzator Barix IPzator technology is designed for the purpose that the Barix device can create its own IP address according to the network structure in case it can t receive one from your network If DHCP AUTOIP or BOOTP fail IPzator will create an IP address within the subnet and test it starting with x x x 168 and if occupied incrementing by one If the address works and is not being used by another device on the network it will give the address to the Barix device 8 1 6 MAC address Abbreviation for Medium Access Control a MAC is a unique address number form
3. Power on the device and wait for the update to finish The device will reboot automatically NOTE All other settings except the network 3 Rescuing the PS16 using the serial port is more complex and requires some engineering work Please contact BARIX Support to get more information BARIX AG 74 91 settings will be lost 6 2 Restoring Factory Defaults of PS16 This new feature has been added as a software replacement for the missing reset button in PS16 stations In some cases forgot web UI password loading corrupted FW image etc the access to the web UI of the ICMASTER may be lost In such a situation the one of the possible recovery solutions on the BARIX devices is to press and hold the reset button while powered on The device will revert to factory defaults and reboot However since PS16 stations do not have HW reset button this procedure is not applicable In this case follow the procedure below to revert to factory defaults e Press and hold key 1 lower left at startup A message will appear on the display asking you to confirm e Toconfirm press key 16 upper right within 3 seconds without releasing key 1 otherwise the unit will continue booting normally After confirming and releasing all keys the factory defaults are restored and the unit reboots Listen to the SonicIP and note down the IP address 4 Another recovery solution is to do a serial rescue using the serial port see se
4. ex BARIX Exstreamer 110 then the VSC LCD cannot be used and stays blank 3 3 ICCLIENT Web home page The device home page is dynamically auto refreshed every second and shows some useful runtime application details Illustration 5 ICCLIENT home page HOME CONFIGURATION ST _ DEFAULTS UPDATE ET Intercom Client Station APPLICATION STATUS BARP Station ID 1 Current Status IDLE AUDIO LEVELS Input Level 127 dB Output Level 127 dB Under the APPLICATION STATUS section is visible the station ID and the current application status BARIX AG 39 91 Under the AUDIO LEVELS section input and output audio levels are displayed in dB 3 4 ICCLIENT Web configuration page As in ICMASTER the ICCLIENT application can be configured in a fast fashion Clicking CONFIGURATION top menu button a BASIC SETTINGS page will be displayed All the application options are then available clicking the ADVANCED SETTINGS left menu button 3 4 1 BASIC SETTINGS The BASIC SETTINGS page is accessible clicking the CONFIGURATION button in the top menu it shows the most important options to be set up for a quick configuration BARIX AG 40 91 Illustration 6 ICCLIENT Application basic settings Web Page HOME CONFIGURATION ETS DEFAULTS UPDATE REBOOT i Intercom Client Station e Basic Settings BASIC SETTINGS Advanced Settings BARP Station ID 1 Apply Cancel Duplex Mode Half Full Use AI
5. name and password The user name can be omitted but the new password has to be supplied in order to see the web configuration BARIX AG 37 91 3 Running ICCLIENT 3 1 About ICCLIENT The ICCLIENT application has to be run on all client endpoints from the ICPAGING system The ICCLIENT can play BGM and paging messages initiate a call session to two preconfigured ICMASTER stations and send periodically its current status Being the slave component from the master slave architecture the ICCLIENT does not have the possibility to control other devices from the ICPAGING system 3 2 Available keys The ICCLIENT application uses the Input 0 key 1 and Input 1 key 2 that are available on the connector of the supported BARIX devices The mapping of the keys is the following Key 1 Call ICMASTER station 1 The id or IP of the ICMASTER station is configured via the ICCLIENT web configuration page Key 2 Call ICMASTER station 2 The id or IP of the ICMASTER station is configured via the ICCLIENT web configuration page If the ICCLIENT is configured to operate with the AIPHONE door panels then the hardware inputs are ignored and the key 1 press is emulated by the firmware The IP of the ICMASTER station 1 is only used in this case BARIX AG 38 91 Note The ICCLIENT can use the HAI Volume Source Control unit together with the BARIX IR Remote Control However if the ICCLIENT is run on BARIX device with its own LCD display
6. 5 3 Configuring the master station 5 3 1 Initial setup Get the latest version of the ICPAGING ABCL software from BARIX download page Unzip the file Connect the ICMASTER station to the LAN and power it on Note down the IP address announced by the Sonic IP and point the browser to that address The application page of the PS16 will be displayed Click on the Update tab of the current installed firmware then click on the Please click here to start the update to go to the update page You will see the update page Click on Browse then navigate to the update_rescue compound bin in the directory where you have unzipped the abcl_icpaging_vOxxxxxx zip file Select it then click on the Upload button to continue BARIX AG 61 91 Update Barix Bootloader V99 12 Sep 29 2008 Resource Browse Upload Reboot Advanced Update Illustration 12 Device upload web page Reboot the device when the update is finished and open the web UI at the announced IP address Once the device reboot click on DEFAULTS top menu button and apply defaults The device will reboot again with default settings Note default ICPAGING running application is ICMASTER when compound bin is loaded and defaults settings are applied The package supplied 2 additional binaries update rescue compound master bin and update rescue compound client bin they respectively contain ICMASTER or ICCLIENT as the
7. AAA ico en eae cioe eee eee ene 34 2 5 2 6 O CORE Ol iiir eroe ier icit crinis ec eae 35 CAS A ri eee one cereo ete cree 35 3 R nning ICGLIENT siia saca cen erc ri a rk rai ini 38 3 1 About ICGLIENT sisi etae eben ri cta tein a iiia 38 BARIX AG 3 91 923 230 INEEWODER ica seas ies ses acca sas A 42 3 4 2 2 BARP GOhlrol iiu ee eiiis te eie eese 43 LA AAPP 44 3 4 2 4 QUO Call eet eee nece acte 47 3 4 2 5 Background MUSIC xissasini 48 3 1 2 6 E nude as ee ee ud 50 3 4 2 7 MO CORO aci enciende circu td ida ua 51 3 1 2 8 SECUN noia LI Led 52 5 Implementing example paging system eeeneneeee 59 5 1 Necessary components ceeeeee rennen eene eene eene 59 5 2 System layoUt cer credis iiaiai adaini iii 59 5 3 Configuring the master station eese 61 5 3 1 Initial setup ii 61 55 Configuring the cash desk station 66 5 5 1 Initial setup E E E ET EE 66 5 6 1 Initial Setup uini 67 56 2 General SENS reet eese enean 67 5 6 3 BGM player settings eeeeennnnnnnnnnnnne 68 BARIX AG 4 91 5 6 4 Connecting the Volume Source Control VSC unit 68 5 7 Configuring the PC for BGM distribution 69 5 1 1 Hardware requireMentS ommcmoccoocnoccocccccccocenccec
8. Phone 9 No O Yes BARP Station ID The system ID of this client station The ID is used to identify the unit at the master station Default setting is 1 Duplex Mode Choose the desired mode of operation If Half is selected the communication is controlled from the ICMASTER Default setting is Full Use AI Phone This setting is for Annuncicom 200 hardware only which provides support for Al PHONE two BARIX AG 41 91 wire interface Set to Yes if Al Phone is used as a door station In this case Half operating mode is recommended Default setting is No 3 4 2 ADVANCED SETTINGS The ADVANCED SETTINGS page is accessible clicking the Advanced Settings button in the left side menu Illustration 7 ICCLIENT Application advanced settings Web Page Home CONFIGURATION STATUS DEFAULTS UPDATE REBooT Intercom Client Station CON SUE BARP Station ID 1 Network BARP Broadcast Address e Je Je Je jJ BARP Audio Port 5555 Outgoing Call BARP Control Port 5556 Background Music BARP Status Port 35557 e ificati a O VO Control Notification Port 9 No Yes Security Apply Cancel 3 4 2 1 Network This section is the same as in ICMASTER See ICMASTER 2 5 2 1 Network section BARIX AG 42 91 3 4 2 2 BARP Control BARP Station ID The system ID of this client station The ID is used to identify the unit at the master station Default setti
9. biggest at the LSB The composed address map is then transmitted with the smallest byte numbers first as shown on the picture below Byte0 Byte 127 Client Ids 1 8 bits 7 0 Client Ids 1017 1024 bits 7 0 Bits 71654321 0 7 6 5 4 3 2 1 0 Client ID 1 2 3 4 5 6 7 8 1017 1018 1019 1020 1021 1022 1023 1024 Enable Disable 1 0 1 0 1 0 1 0 0 0 0 0 0 0 0 oO Hex A A 0 0 Illustration 16 Address bitmap encoding To find out in which byte is the client ID we would like to select we use the integer division operation IDbyte Client ID 1 8 Let s see what it means in terms of our example Let s find in which byte is our client ID 21 IDbyte 21 1 8 2 The result is the biggest number which multiplied by 8 does not exceed ID 1 The other result from this operation is called reminder and is in fact the number that completes to ID 1 BARIX AG 78 91 ID 1 result 8 reminder Now to find which bit within this byte we take the reminder which for ID 21 is 4 from the integer division and subtract it from 7 In other words IDbit 7 4 3 which means that we have to set bit3 from byte2 ByteO Byte1 Byte2 Client Ids 1 8 Client Ids 9 16 Client Ids 17 24 Bits 7654 3210 77654 32107654 32 10 Enable Disable 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0
10. default running application 5 3 2 General settings Now it is time to configure our master station Once PS16 is rebooted open the Settings page BARIX AG 62 91 and eventually set up the network settings Network setup is not mandatory if a DHCP server router exists in the network anyway for example a fixed IP address instead of default assigned DHCP address can make the device access easier in future reconfiguration operations 5 3 3 ICMASTER settings Now it is time to configure the ICMASTER specific settings Click on the Advanced Settings tab and set the following items Basic Settings or Audio section Duplex Mode Choose Half e Paging section Group 1 Address Map Click on the View Modify button to open the address map configuration dialog click Clear All then select id 1 only and click apply After device reboot click Close e Paging section Group 2 Address Map Click on the View Modify button to open the address map configuration dialog click Clear All then select id 2 only and click apply After device reboot click Close e Paging section Group 3 Address Map Click on the View Modify button to open the address map configuration dialog click Clear All then select id 3 only and click apply After device reboot click Close Group 4 Address Map BARIX AG 63 91 Click on the View Modify button to open the address map configuration dialog
11. record unattended message or with key 7 to record custom message Recording stops when this button is released Key 9 select page group 1 The address bitmap assigned to this key is configured from the related ICMASTER web UI address map configuration page Key 10 select page group 2 The address bitmap assigned to this key is configured from the related ICMASTER web UI address map configuration page Key 11 select page group 3 The address bitmap assigned to this key is configured from the related ICMASTER web UI address map configuration page Key 12 select page group 4 The address bitmap assigned to this key is configured from the related ICMASTER web UI address map configuration page Key 13 select page group 5 The address bitmap assigned to this key is configured from the related ICMASTER web UI address map configuration page BARIX AG 19 91 Key 14 select page group 6 The address bitmap assigned to this key is configured from the related ICMASTER web UI address map configuration page Key 15 select page group 7 The address bitmap assigned to this key is configured from the related ICMASTER web UI address map configuration page Key 16 select page group 8 The address bitmap assigned to this key is configured from the related ICMASTER web UI address map configuration page Keys 17 112 select client ID 17 112 Important note When the ICMASTER is run in HDX mode pressing key 1 when there
12. the color of this point button from white to dark grey within 60 seconds Buttons on ICgraph window Show group Show member toggles view between point and group Intercom allows bi directional communication with a single point point must request ring before Clear All resets active communication and or point buttons to normal state Must be used to finish every communication from and with ICgraph Start Paging Stop Paging allows to make paging announcements to selected points and or groups For use this function one many or all points groups should be selected before clicking the Start Paging button Mute ON Mute OFF mutes unmutes the ICgraph PC microphone Relay open allows switching of the remote relay for 3 seconds on selected device Works only during Intercom mode BARIX AG 55 91 Menu OFF Menu ON displays or hides menu buttons below this button Show events Hide events displays or hides event window the event window is a helpful tool which shows all current point activities Show LOG Hide LOG displays or hides LOG window this window displays all ICgraph activities even the background activities Show records Hide records displays or hides Record window this window shows all recording you made with ICgraph or from the sub folder RECORDS From here window select recordings or self made audio files can be sent to the selected devices Play message Stop message allows t
13. to the Internet or you are connected to the Internet and want to operate your Barix Barionet on an intranet you should use one of the sub networks below for your network These network numbers have been reserved for such networks If you have any questions about IP assignment ask your Network Administrator Private IP networks by class Class Network A 10 x x x B 172 16 x x C 192 168 0 x Network RFC s For more information regarding IP addressing see the following documents They can be found on the Internet RFC Description 950 Internet Standard Subnetting Procedure 1700 Assigned Numbers 1117 Internet Numbers 1597 Address Allocation for Private Internets BARIX AG 89 91 9 Legal Information O 2013 Barix AG Zurich Switzerland All rights reserved All information is subject to change without notice All mentioned trademarks belong to their respective owners and are used for reference only Barix and ICPAGING are trademarks of Barix AG Switzerland and are registered in certain countries For information about our devices and the latest version of this manual please visit www barix com BARIX AG 90 91 Illustration Index Illustration 1 ICMASTER keyboard layout eee 17 Illustration 2 ICMASTER home pagge ener 22 Illustration 3 ICMASTER basic settings page eene 23 Illustr
14. 0 01 0 0 0 Hex 0 0 0 0 8 8 Repeating these calculations for client ID 17 we find that bit7 of byte2 has to be set Looking at the BIN DEC HEX conversion table we see that 1000 is 0x8 in HEX format which explains the 0x88 value we see for group 1 in the Group buttons address bitmap summary 6 5 BIN DEC HEX conversion Hexadecimal digits have values from 0 15 represented as 0 9 and as A for 10 to F for 15 The following table can serve as a conversion chart Bin DEC Hex Table Decimal Binary Hexadecimal 0 0000 0 1 0001 1 BARIX AG 79 91 Decimal Binary Hexadecimal 2 0010 2 3 0011 3 4 0100 4 5 0101 5 6 0110 6 7 0111 7 8 1000 8 9 1001 9 10 1010 A 11 1011 B 12 1100 C 13 1101 D 14 1110 E 15 1111 F To convert a binary value in a hexadecimal representation the upper and lower four bits are treated separately resulting in a two digit hexadecimal number BARIX AG 80 91 7 Troubleshooting Below just a brief table to help solving the main known issues 1SSUE Description Possible cause and remedy action Device boot but web UI home page frames shows ERROR 400 ICPAGING has been uploaded over an existing different ABCL fw based application Click DEFAULTS on the top menu and apply defaults Device not visible in the LAN network An IP assignment server is missi
15. 0502 and10503 Now the MP3_RTP_streamer is configured and should be streaming music on address 224 1 2 4 and ports 10501 10503 5 8 Testing the Paging system 5 8 1 Recording a custom message The ICMASTER allows the user to pre record an announcement to be sent when desired to the selected targets Make sure there are no clients selected by pressing the Cancel Sel key key 7 Keep pressed the custom message key key 6 Icd display will show a warning Nothing Selected then press key 5 and release it to start recording key 6 can be released from now Recording custom message will be displayed on the PS16 LCD Press again key 5 a second time to stop recording and save the message to the USB stick BARIX AG 71 91 5 8 2 Rejecting a call Press the call button on the Door or cash desk station Wait for the ICMASTER to display the message with the caller ID and play the ring tone then press key 3 to reject the call The client should play the busy tone 5 8 3 Answer a call Press again the call button on the client When the call indication is received on the master press key 1 and keep it pressed for a while As itis a PTT key the ICCLIENT is switched to listen mode when pressed and to talk mode when released Release the key to listen to the client and push it again to talk Press key 2 to toggle the relay on the client or key 3 to hang up the call 5 8 4 Paging Select the desired clients to be pa
16. BAHIX THE VOICE OF SIMPLICITY ICPAGING Application User Manual ICPAGING intercom and paging system ICPAGING ABCL FW version Doc release version ICMASTER ICCLIENT ICGRAPH Master HD configuration ICGRAPH Master FD configuration VA1 10 31 01 2013 V01 09 V01 07 V1 0 V1 0 O 2013 Barix AG all rights reserved All information is subject to change without notice mentioned trademarks belong to their respective owners and are used for reference only REVISION TABLE Date Version Who Change 09 07 12 Draft AD First draft 10 07 12 Draft SG Added ICgraph chapter 28 08 12 001 AD Updated for IcPaging 1 05 30 08 12 002 AD Updated for IcPaging 1 06 10 09 12 003 AD Updated for IcPaging 1 07 28 09 12 004 AD Updated for IcPaging 1 08 25 10 12 005 AD Updated for IcPaging 1 09 31 01 13 006 AD Updated for IcPaging 1 10 Table of Contents 1 Introduction 1 1 About ICPAGING BARIX AG 2 91 1 4 Additional docurtients iu 12 1 5 ICPAGING ABCL Firmware eee rere nenne 12 2 5 ICMASTER Web configuration pages 23 2 5 1 BASIC SETTIN OS iacu icc daran andara 23 2 5 2 ADVANCED SETTINGS cuina cce cose 26 25 23 NO A rec ceni saec ccce s 26 25 22 BABP COBEIOL neri erede ea diii 29 CAU AAA 31 2 50 24 Incoming Gall e al 33 2 5 2 5 e
17. BARIX Exstreamer 100 A pair of powered stereo speakers A telephone style door station A PC for streaming music BARIX MP3 RTP Streamer application 5 2 System layout Let s implement an example system for the needs of a small shop The proposed layout is shown on the figure below BARIX AG 59 91 Illustration 11 Example intercom and paging system m E Y mg PC runni ng a Mcast 224 1 2 4 MP3_RTP_Streamer 3 yi Chanrels 3 Start port 10501 d P Full duplex Lf sas ID1 AS lab station i i Exstr100 LAN WAN 103 VSC amp IR IE JA Door control unit Pani og he oos AEN PS16 Ann100 a i A ID 1001 ID2 ay AIPHONE Stereo speakers We will need one Master station for sending messages and controlling the background music that will be located at the security room one station for delivering high quality music in the shop area one door station at the stock delivery entry and one telephone at the cash desk The music delivery is done by a PC running the BARIX MP3_RTP_Streamer but could be also done with a BARIX Instreamer device The BGM playback can be controlled by the ICMASTER or locally using the HAI Volume Source Control unit For the door station BARIX Annuncicom 200 is being used as it provides the suitable two wire interface for connecting the AIPHONE panel As this device is half duplex the whole system needs to be configured in half duplex mode BARIX AG 60 91
18. CONFIGURATION status DEFAULTS UPDATE REBOOT 755 Annund Intercom Master Station Current Profile PS16 FD BASIC SETTINGS Help BARP Station ID 1001 us a BAR Hands Free O Yes Y No clien Apply Cancel mes m Defa Group 1 Address Map View Modify 10 clients selected A Dupl Choc Defa Han Whe the t If the Inpu in tal The Page of pri and Defa BARIX AG 23 91 e BAPP Station ID Enter here the BARP system ID of this master station The ID is used from the clients to identify the source of the control messages in multimaster environment Default is 1001 Duplex Mode Choose the desired mode of operation Default setting is Full e Hands Free When set to yes and HDX mode is enabled the talk listen mode can be voice controlled In Intercom mode if the voice level exceeds the one set in Input Trigger Level the master is switching in talk mode and the client in listen mode In Page mode the Page key needs to be pressed once instead of press and hold to activate the paging and pressed again to stop Default setting is No Hands Free Keys The function of the keys changes depending upon the device and the configuration Full Half duplex BARIX AG 24 91 Function FD Key HD Key PS16 Accept Call IC 1 Reject Call IC 3 Close Call IC 10r3 Open Relay IC 2 Start Paging 2 blinks whilst Paging Nm woo Stop Paging 2 PS1 and other 2 button Annuncicoms Ac
19. Input Source Choose the desired input source Default setting is Mic Duplex Mode Choose the desired mode of operation If Half BARIX AG 44 91 is selected the communication is controlled from the ICMASTER Default setting is Full Use AI Phone This setting is for Annuncicom 200 hardware only which provides support for Al PHONE two wire interface Set to Yes if Al Phone is used as a door station In this case Half operating mode is recommended Default setting is No Microphone Gain Microphone gain dB increase if your microphone signal is too faint decrease if it s too loud or overdriven Default 21 dB A D Amplifier Gain A D converter preamplification in dB Use this setting to achieve the right balance to your connected equipment Increase if the audio signal too faint decrease if it s too loud or overdriven Default 0 dB Default Paging Volume The setting is the default volume used for paging and intercom audio Choose between 0 and 100 in 5 steps Default 5026 Minimal Paging Volume BARIX AG 45 91 The setting is used as a minimal volume limit in case the volume is set from the paging source Choose between 09 65 and 10096 in 5 steps Default 7096 e Maximal Paging Volume The setting is used as a maximal volume limit in case the volume is set from the paging source Note a control volume of 0 remote muting is anyway accepted Choose
20. We will dedicate this group to select all then we need to check clients ID 1 2 and 3 So click Clear All select 1 2 and 3 then click Apply at the bottom of the Group configuration page The device will reboot click Close to exit address map configuration page NB Do the group key assignment after you have applied all other ICMASTER settings Otherwise the changes will be lost and only the group mask will be saved After reboot click CONFIGURATION and Advanced Settings button and check if the number of the selected clients for the groups is correct It should look like this Illustration 13 Group buttons address bitmap summary PAGING Group 1 Address Map Group 2 Address Map Group 3 Address Map Group 4 Address Map View Modify View Modify View Modify View Modify 1 clients selected 1 clients selected 1 clients selected 3 clients selected For more detailed explanation on the address bitmap configuration values see sections Understanding BARP address bitmaps Paging section Audio Multicast Socket Configure 224 1 2 3 leave the default port as 12345 BARIX AG 64 91 Leave all other settings to their default values and click Apply With this the ICMASTER station configuration is finished 5 4 Configuring the door station 5 4 1 Initial setup Do the initial setup as described in the ICMASTER General settings section After uploading the SW if the default running a
21. age HOME CONFIGURATION STATUS DEFAULTS UPDATE REBOOT Intercom Master Station APPLICATION STATUS BARP Station ID 1001 Current Status IDLE AUDIO LEVELS Input Level 127 dB Output Level 127 dB 9 Select Group 1 1 Accept Call KEYBOARD LAYOUT 10 11 12 13 14 15 16 Select Select Select Select Select Select Select Group2 Group3 Group4 Group5 Group6 Group7 Groups 2 3 4 5 6 7 8 Record Rec Play Close Unatt Unatt Custom Cancel Dynamic Page Call On Off Message Message Sel Group The device home page is dynamically auto refreshed every second and shows some useful run time application details Under the APPLICATION STATUS section is visible the BARP station ID and the current application status Under the AUDIO LEVELS section input and output audio levels are displayed in dB The section KEYBOARD LAYOUT shows the layout of the keys as supported and used in the current hardware BARIX AG 22 91 2 5 ICMASTER Web configuration pages The configuration of the ICMASTER is very intuitive and easily done via the web UI Example snapshots of the basic settings and advanced settings pages are shown on Illustration 3 and Illustration 7 2 5 1 BASIC SETTINGS The BASIC SETTINGS page is accessible clicking the CONFIGURATION button in the top menu it shows the most important options to be set up for a quick configuration Illustration 3 ICMASTER basic settings page Home
22. annel name _ IP Port Start Stop Playlist File name Song Buffer Status Double click t lllustration 14 MP3_RTP_Streamer main window unconfigured We re going to configure it to play the 3 BGM channels plus the local channel The three BGM channels will stream from ports 10501 10502 10503 while the local channel expect audio input from local line in for devices that supports the line HW input Double click at the MP3_RTP streamer window to open the channel add dialog lllustration 15 MP3_RTP_Streamer configuration dialog 2 modify channel 1 eoo Channel name Channel 1 Music lib dir part d archivio sviluppo2 barix sounds STL PLAYLIST Playlist playlist m3u 4 Start time 00 00 y Stop time 00 00 M Buffer size 2x v IP address 192 168 0 255 Port 11001 Repeat V Shuffle C Update Library Modify Cancel Delete Put the channel name first ex Channel 1 for channel 1 Set the IP to the multicast group 224 1 2 4 and the port to 10501 Click Music lib dir and navigate to the BARIX AG 70 91 directory where your mp3 files and playlists reside Click Playlist and select the playlist for this channel The playlists can be created with iTunes WinAmp or any other mp3 capable player Click on Create and repeat all these steps to add channels 2 and 3 using ports 1
23. ast AUressS ccococccreccooccnnnocecocannarrrncanercaneecaneecaneenanes 87 81 18 IP NGUTSSK iii a ce iii Desi ris ca a 88 8 1 19 Private IP Networks and the Internet 89 8 1 20 Netwotk BEG Susini 89 9 LESA TETTE IEEE 90 BARIX AG 6 91 1 1 1 Introduction About ICPAGING ICPAGING is a fully functional solution for building intercom and paging systems over IP based networks With ICPAGING BARIX devices can be easily configured and become part of the paging system in few minutes Being designed with a master client architecture the ICPAGING application can be configured to run either as a master called ICMASTER or as client called ICCLIENT The communication between the master and the client components of the paging system is implemented using the Barix IP protocol BARP The ICMASTER station can control the ICCLIENT s mode of operation send broadcast paging messages to any or all of them and activate their relays to drive different peripherals Multiple masters can coexist and be configured within a system Also the in the package contained ICgraph software Java based PC software can be used as ICMASTER system station The ICCLIENT stations are typically used as door intercom stations or paging stations with background music playback They can also be configured to initiate an intercom connection with up to two master stations BARIX AG 7 91 1 2 Features Sy
24. at is ICgraph and how to use the ICgraph master Chapter Implementing example paging system explaining how to create a simple intercom and paging system using BARIX ICPAGING solution BARIX AG 13 91 Chapter Additional information explaining how to rescue a device via the serial port how to use the ICPAGING in multimaster environment and providing a quick reference to BARP address bitmap handling and BIN DEC HEX conversion Chapter Dictionary giving a short explanation of some of the most important terms used in this manual BARIX AG 14 91 2 Running ICMASTER 2 1 Booting up PS16 ICMASTER Power up the PS16 If the SoniclP is enabled you will hear the IP which the PS16 got from your DHCP server After that the device will start detecting the USB stick The following message will be shown on the PS16 LCD while the check is being performed Checking USB sanity When the check was successful the ICMASTER idle message will be displayed IcMaster FDX 1 02 04 07 2012 16 keys In case of broken or missing USB stick the application will display an error message and will exit Bad USB stick fs In this case please power off the PS16 remove the two screws from the bottom open the cover and replace the USB stick with a new one formatted with FAT32 file system Also have in mind the following important notes NOTE 1 f you plan to use the ICMASTER on Annuncicom 100 200 please plug in a for
25. ation 4 ICMASTER advanced settings page eee 26 Illustration 5 ICCLIENT home pagge eene 39 Illustration 6 ICCLIENT Application basic settings Web Page 41 Illustration 7 ICCLIENT Application advanced settings Web Page 42 Illustration 8 ICgraph application Full duplex 54 Illustration 9 ICgraph half duplex Intercom buttons 58 Illustration 10 ICgraph Point button states eere 58 Illustration 11 Example intercom and paging system 60 Illustration 12 Device upload Web pagge eeeeeeeeeeeeeeee 62 Illustration 13 Group buttons address bitmap summary 64 Illustration 14 MP3 RTP Streamer main window unconfigured 70 Illustration 15 MP3 RTP Streamer configuration dialog 70 Illustration 16 Address bitmap encoding eese 78 Barix AG Seefeldstrasse 303 8008 Z rich E VOICE OF SIMPLICITY SWITZERLAND T 41 43 433 22 11 F 41 44 274 28 49 www barix com salesObarix com support barix com BARIX AG 91 91
26. atted in hexadecimal format and given to each computer and or network device on a computer network Because a MAC address is a unique address a computer network will not have the same MAC address assigned to more than one computer or network device Example A1 B2 C3 D4 E5 F6 8 1 7 Netmask A number used to identify a sub network so that an IP address can be shared on a LAN Local Area Network A mask is used to determine what subnet an IP address belongs to An IP address has two components the network address and the host address For example consider the IP address 150 215 017 009 Assuming this is part of a BARIX AG 84 91 Class B network the first two numbers 150 2 represent the Class B network address and the second two numbers 017 009 identify a particular host on this network The Netmask would then be 255 255 0 0 8 1 8 Static IP 8 1 9 VSC A Static IP is a fixed IP address that you assign manually to a device on the network It remains valid until you disable it Volume Source Control unit This an universal wall mountable control accessory for the Barix audio products range It provides two digit LED display control knob and a IR port 8 1 10 IP Addressing An IP address is a 32 bit value divided into four octets of eight bits each The standard representation is four decimal numbers in the range of 0 255 divided by dots Example 192 2 1 123 This is called decimal dot notation T
27. between 096 and 10096 in 5 steps Default 90 Default BGM Volume The setting is used as the default BGM volume at device start up Choose between 0 and 10096 in 5 steps Default 50 Minimal BGM Volume The setting is active if HW Volume Source Control is used Choose between 0 and 100 in 5 steps Default 7026 Maximal BGM Volume The setting is active if HW Volume Source Control is used Choose between 096 and 10096 in 5 steps Default 90 BARIX AG 46 91 Notification Volume Sets the default notification volume In case a notification message is received and the paging volume is lower than notification volume notification volume is used Default 90 3 4 2 4 Outgoing Call e Call Masters by Configures the way the master stations are called If set to IP address the masters are called by unicasting the call request command to the master IP If set to ID then the masters are called by broadcasting the call request command with the destination ID2master ID Select the needed option so see the corresponding configuration fields Default IP address e Master Station ID When Call Master by BARP ID is set enter the system ID of the related 1 to 4 master station The first master station is called after pressing the Button 1 activating the first digital input Default setting is for master stations 1 to 4 respectively 1001 1002 1003 1004
28. ce will announce its IP address over the audio output when the device BARIX AG 26 91 boots up Default setting is yes IP Address Netmask Enter the 4 values of the desired device IP address e g 0 0 0 0 for automatic discovery DHCP Bootp IPzator AutolP or a specific IP for an internal LAN Default value 0 0 0 0 Enter the 4 values of the desired Static IP e g 0 0 0 0 for a default Netmask depending on the used IP Address 255 255 255 0 for a C class network Gateway IP Address Enter the 4 values of the desired Gateway IP address e g 0 0 0 0 for no Gateway or the IP of the gateway in your LAN Note The Gateway has to be set only when connecting to other devices over the WAN through a router Default 0 0 0 0 Primary DNS In this field you can give the desired primary and alternative DNS IP address to be able to connect to URLs e g www radio com Example 195 186 1 111 Default 0 0 0 0 Alternative DNS BARIX AG 27 91 In this field you can type the desired alternative DNS IP address in case the primary DNS is not reachable Example 195 186 4 111 Default 0 0 0 0 e Syslog Address Destination address for syslog messages sent by the BCL program via the SYSLOG command Set this to your syslog logging machine if your syslog messages are recorded centrally If set to 0 0 0 0 syslog messages are broadcasted Default 0 0 0 0 DHCP Host Name Name
29. cept Call IC A 1 A 1 Close Call IC A 1 A 1 B 2 Open Relay IC B 2 B 2 Start Paging B 2 Stop Paging B 2 e Group 1 Address Map Allows to set up the first group 1 of destination targets Click related View Modify button to setup the group A label on the right shows the number of selected clients in this group Default setting is id s 1 to 10 selected BARIX AG 25 91 2 5 2 ADVANCED SETTINGS Illustration 4 ICMASTER advanced settings page HOME CONFIGURATION STATUS DEFAULT UPDATE REBOOT o o Intercom Master Station Current Profile PS16 FD NETWORK SETTINGS i Use SonicIP O Yes No IP Address 192 1e8 o J is Advanced Settings Netmask 0 o j o o Gateway IP Address o fo o J o Primary DNS 20009 18 CD EA CU A CU Incoming Call Pagina Alternative DNS 0 o j o o 1 0 Control Syslog Address 0 o J le o J DHCP Host Name apply Cancel Web Server Port 80 Default Ethernet Port ETH1 gt SNMP System Name J SNMP System Location SNMP System Contact The ADVANCED SETTINGS page is accessible by clicking the Advanced Settings button in the left menu it contains and allows to configure all the application options organized in specific subsections The advanced settings page shows all the configurable options 2 5 2 1 Network Use SoniclP If set to yes the devi
30. ction Updating a device using the RS 232 serial port BARIX AG 75 91 e Open the web page at the announced IP address and change the application from ICCLIENT to ICMASTER Click Apply to reboot After reboot reconfigure the ICMASTER as it was before 6 3 Configuring ICPAGING in multimaster environment In some cases multiple masters may be needed in the paging system For example a door station may need to ring to the reception at the entrance during normal working hours and to the security room at night For this purpose ICPAGING supports several multimaster scenarios 6 3 1 Call Failover scenario In this case maximum 4 masters can be called by the client If one of the first two masters in the client IP ID list are called and it is in call reject mode then the client starts calling the other three masters in a chain However if the first master does not reply or any other master called in the chain then the client will timeout and may not connect to any master To prevent this happen the Call next Master on the client must be enabled BARIX AG 76 91 6 3 2 6 3 3 Call all Call all masters scenario For that mode the masters must be addressed by IP This is done by setting the ICCLIENT Call Masters by and the ICMASTER Call Master by configuration options to IP Address Then it is enough to set one of the first two master IP addresses in the ICCLIENT list to IP addres
31. duplex mode ICgraph configuration the Intercom button will after activation change to Intercom Talk yellow in this mode you can talk to the ringed selected device To listen to the device click on the Intercom Talk button The button name will change not to Intercom Listen green BARIX AG 57 91 Illustration 9 ICgraph half duplex Intercom buttons e L Clicking on the Intercom Listen button with change again to Intercom Talk button To finish the communication press the Clear All button Note for Intercom only one ringing device should be selected at the same time no Groups and not multiple devices If the device is not ringing anymore then the point button will stay in magenta none blinking In this mode only a one way communication to the device for max 10 seconds is possible when using the Intercom button lllustration 10 ICgraph Point button states undiscovered ringing activated selected EN NE discovered rang BARIX AG 58 91 5 implementing example paging system 5 1 Necessary components For better understanding the usage of ICPAGING solution proposed by BARIX we will try to implement a small paging system supporting all the advertised features For the system shown below the following components are needed BARIX Annuncicom 200 BARIX Annuncicom 100 AIPHONE door panel PS16 Paging station One PS16 48 keys extension optional
32. e the service is enabled channels can be switched using the Barix VSC accessory connected to the device serial port In addition once the service is enabled for devices supporting an HW line input a local line in channel channel 0 is available and selectable Example of BGM service configuration This example shows how to setup the BGM service to listen to multiple broadcast streams for a desired scenario as in the table below Channel Desc 0 Local Line Input 1 Audio Stream 1 2 Audio Stream 2 3 Audio Stream 3 BGM Broadcast Address set to 0 0 0 0 BGM First Broadcast Port set to 11001 default BGM Available Channels set to 3 BGM Start Channel set to 1 allows Audio Stream 1 to be played at startup BGM Broadcast Address Enter the broadcast multicast address of the background music streaming server If set to 0 0 0 0 then broadcast is used Default setting is 0 0 0 0 BARIX AG 49 91 BGM First Broadcast Port Enter the broadcast multicast port of the first channel background music streaming server The BGM streaming could be provided by multiple streamers but they have to be configured to use consecutive port numbers If set to 0 the BGM functionality is disabled Default setting is 11001 BGM Available Channels Enter the number of the available background music channels If set to 0 then BGM will be disabled If greater than 0 a local channel 0 will be available for local li
33. efaults function on the Reset button In order to revert all settings to factory defaults keep the Reset button pressed until the red LED starts blinking approx 10 seconds Default enabled BARIX AG 35 91 Update Function Enable or disable the WEB Update function of the device If the Update function is disabled the only way to update the firmware is to use the serial rescue Default enabled Set Password This is visible as long as no password is set Enter a password up to 25 characters and hit the Apply button After the restart you should close the browser window and open a new browser window You will be asked to supply user name and password The user name can be omitted but the password has to be supplied in order to see the web configuration Old Password New Password These fields are visible as long as a password is set To allow free access clearing the password enter the old password and leave the field New Password empty Enter the old password in the password field above the Apply button as well and then hit the Apply button After the restart you will not be asked for user name and password anymore To change the password enter the old password and enter the new password in the field New Password Enter the old password in the password field above the Apply button as well and then hit the Apply button BARIX AG 36 91 After the restart you will be asked for user
34. eneccannaccneneness 69 5 7 2 the MP3 RTP Streamer 69 5 8 4 Recording a custom messagge eeeeenn 71 5 8 2 Rejecting a Call iiie nnn 72 5 8 3 Answer aca DEEST 72 6 3 Configuring ICPAGING in multimaster environment 76 6 3 1 Call Failover scenario eese 76 6 3 2 Call all masters scenario eere nnne 71 6 3 3 Call all failover scenario eere rere T7 6 4 Understanding BARP address bitmaps 77 6 5 BIN DEC HEX conversion eene 79 7 Troubleshooting a a 81 8 DiCHONAN ran eror isse cce eee ce ie res eoe conce 83 Bull DAG Pista 83 We MI AAA NAO 83 A AO 83 Bop A AT Rods 83 9 1 5 IIBZATOE eani duccuz ci ioeu eia ire ooa toca ra ea oE eaaa 84 81 6 MAG address aiaa aaa eaaa aaaeaii 84 8 7 Netas en iaia a e a a 84 84 8 Statie IP oi dada ai aaaeaii 85 A A O 85 BARIX AG 5 91 8 1 10 IP Addressing inns 85 8 1 11 Glass A BOBWOCTK uiii niii is 86 811 12 Glass B HetWOFK uisi cina iie es casa dir 86 8 1 13 Class C NETWORK ciii o ieri iaa iai nianu Sosa di essais sdeessid 86 8 1 14 Class D network eeeee esee enne eene nnn rnn nit 87 81 15 Class E DelWOEK iiis iocis asas cases sara Era cosa reise uiae 87 81 16 Network Address 87 8 1 17 Broadc
35. er here the priority of the audio messages sent by this master station This setting is useful in multimaster environment when a client receives audio messages from many masters simultaneously In this case the client will play the stream with the highest priority The priority must be in the range 1 254 Priority 0 the highest is reserved for emergency priority port priority 255 the lowest is reserved for BGM Default setting is 127 BARP Broadcast Address By default the ICCLIENT uses a broadcast IP to listen send on the BARP ports Modify the BARP IP address to use multicast if communication across different networks is desired or if your LAN policy is not allowing broadcast Default setting is 0 0 0 0 broadcast BARP Audio Port Enter the BARP port number to which the master will send audio for paging and established calls In the multicast port and address are configured this port will be used only for incoming calls Paging will be done using the multicast group Default is 5555 BARP Control Port BARIX AG 30 91 Enter the BARP port number to which the master will send control messages Default is 5556 BARP Status Port Enter the destination port number where the master will listen for BARP status messages Default is 5557 2 5 2 3 Audio e Audio Format Choose between different encoding types and sampling frequencies p law or A law at 8 or 24 kHz Default setti
36. ge please download the Barix Control Language BCL Programmers Manual from our website 1 5 ICPAGING ABCL Firmware Barix provides the ICPAGING solution as a prebuilt ABCL package containing the ICMASTER and ICCLIENT applications The ICMASTER and ICCLIENT are guaranteed to work only when they are from the same ABCL ICPAGING package Using ICMASTER and ICCLIENT from ICPAGING packages with different versions may not work correctly since new functionality are continually being developed 1 6 About this manual 1 6 1 Links to chapters References to chapters e g X Chapter name are red and underlined and serve as direct links BARIX AG 12 91 when viewed in Adobe Acrobat Viewer Click on the link to jump to the referenced chapter click on the left arrow icon to jump back to where you came from 1 6 2 Bookmarks pane in Adobe Acrobat The complete Table of Contents is available in Adobe Acrobat Viewer Click on the Bookmarks pane tab on the left side of Adobe Acrobat Viewer to open it Click on any bookmark to directly jump to the corresponding part of the manual 1 6 3 Chapter overview This manual is divided into the following chapters Chapter Running ICMASTER describing the functionality provided by the ICMASTER the key mapping and the usage of the web configuration UI Chapter Running ICCLIENT giving an overview of ICCLIENT usage and configuration Chapter Running ICgraph mentioning wh
37. ged by pressing the corresponding target group buttons then press and hold the page key key 2 to send the message Release it when finished 5 8 5 Paging the custom message With a group selection active press the custom message key once The prerecorded message will be sent to the selected Ids and once the message has been sent the ICMASTER will BARIX AG 72 91 return to idle mode The LED will blink while sending and the BGM playback should be restored after the message is sent BARIX AG 73 91 6 Additional information 6 1 Updating a device using the RS 232 serial port Sometimes when the device is not accessible via the LAN or the image in the flash memory is corrupted for some reason then a serial rescue may be needed to reset the device to the factory defaults So here are the steps that need to be executed to do the serial rescue e Disconnect the device from the power supply Connect the COM port of the device to the COM port of your computer via a null modem serial cable e Open a terminal in the update rescue directory in your unzipped copy of the ABCP ICPAGING firmware If using Linux or Mac switch to update rescue linux directory e Start the rescue process by executing serialX where X is the number 1 4 of the serial port on the computer e If running on Linux Mac execute the seriald sh script giving the device name of your COM port as a parameter For ex seriald dev tty UC 232AC
38. he IP address is divided in two parts a network and a host part To support different needs five network classes have been defined Depending on the network class the last one BARIX AG 85 91 8 1 11 8 1 12 two or last three bytes define the host while the remaining part defines the network In the following text x stands for the host part of the IP address Class A network Class IP address 1 x x x to 127 x x x Only 127 different networks of this class exist These have a very large number of potential connected devices up to 16 777 216 Example 10 0 0 1 network 10 host 0 0 1 B network IP address 128 0 x x to 191 255 x x These networks are used for large company networks Every network can consist of up to 65534 devices Example 172 1 3 2 network 172 1 host 3 2 8 1 13 Class C network P address 192 0 0 x to 223 255 255 x Class C networks are most common and for smaller companies These networks can consist of a maximum number of 254hosts Example 192 7 1 9 network 192 7 1 host 9 BARIX AG 86 91 8 1 14 Class D network The remaining addresses 224 x x x 239 x x x are defined as Class D and are used as multicast addresses 8 1 15 Class E network No addresses are allowed with the four highest order bits set to 1 240 x x x 254 x x x These addresses called class E are reserved 8 1 16 Network Address The host address with all host bits
39. in a call and there is no other incoming call pressing this key will also hang up the current call session Key 4 clear current target group selection Key 5 enter unattended mode pressing any other key exits unattended mode Clients that try to call a master that is in unattended mode will have the unattended message played to them and the call will be terminated once the message has been played Pressing and holding this key for 4 seconds will enter the master in call reject mode When the master is in this mode and a client calls in instead of opening a call session and sending the unattended message it will send a special message to the client informing that it is not available In this case the client should call the next master in its list NOTE if the ICMASTER does not cancel answer the second call the ICCLIENT will continue ringing and hang up automatically after a certain amount of time configurable via the ICCLIENT web UI NOTE when the unattended mode is disabled from the web UI pressing this key puts the BARIX AG 18 91 master immediately in call reject mode Key 6 when pressed allows to listen the unattended message locally Key 7 when pressed without any selection allows to listen the custom message locally When there are targets selected the custom message is sent to the selected destination s Key 8 record custom or unattended message Press and hold this key together with key 6 to
40. is an active call will not close it In HDX mode key 1 is used as PTT Push To Talk key When pressed the microphone of the ICMASTER is switched ON the speaker turned OFF while the mic of the ICCLIENT is automatically switched OFF and its speaker turned ON 2 3 Running ICMASTER on Annuncicom 100 200 PS1 The ICMASTER can be used also on the Annuncicom 100 200 and PS1 devices with limited functionality Because on these devices there are only two available keys the key mapping is a bit different than the one BARIX AG 20 91 described for the PS16 Full duplex FDX mode Key I answer incoming Close current call Key2 if itis in a call pressing this key will open the relay on the client for 5 seconds When the ICMASTER is in idle mode pressing key 2 will start paging to Group 1 Half duplex HDX mode Key 1 answer incoming call While the call is active it works as a PTT key press and hold to talk release to listen Key2 if itis in a call pressing this key will open the relay on the client for 5 seconds When the ICMASTER is in idle mode pressing key 2 will start paging to Group 1 Press and hold key 1 then press key 2 Close the current call In addition as the PS1 device does not have USB port all features that use it are disabled customized station ring tones unattended mode and custom messages recording BARIX AG 21 91 2 4 ICMASTER Web home page Illustration 2 ICMASTER home p
41. matted USB stick otherwise the application will not start NOTE 2 Depending on your configuration BARIX AG 15 91 the following files may be present on your USB stick UNATTSND this is the recorded unattended mode message CUSTMSG this is the recorded custom message TEST USB an empty temporary file created during USB stick check xxx MP3 station ID specific ring tone files where xxx is the station ID for example 002 mp3 is the ring tone for station ID 2 None of them is required for the application to boot but it is advised to backup these files without the TEST USB as it will be deleted and recreated during boot and copy them to the new USB stick to keep the same configuration 2 2 PS16 Keyboard Layout The PS16 Paging main unit has 16 functional buttons a flexible microphone speaker and 2 line LCD Optional extensions with 48 keys can be attached on the right side of the PS16 main unit Key layout for PS16 as well as for every master device is shown in the web Ul home page as in Illustration 1 BARIX AG 16 91 Illustration 1 ICMASTER keyboard layout 9 Select Group 1 de Accept Call KEYBOARD LAYOUT 10 Select Group 2 2 Page Relay 11 12 13 14 15 16 Select Select Select Select Select Select Group3 Group4 Group5 Group6 Group7 Groups 3 4 5 6 7 8 Close Cancel Unatt Unatt Custom Call Selection On Off Message Message Record If a PS16 exte
42. ne input Default setting is 0 BGM Start Channel Enter the background music channel to start playing after a reboot If it more than the available channels then the last one will be used Default setting is 0 3 4 2 6 Serial Serial Port Selects the way the device serial port will be used Select VSC Panel here to use Barix VSC accessory with this application Default Intercom Client Software BARIX AG 50 91 3 4 2 7 O Control e Relay 1 Control Set here the default relay behaviour Available values are always off the relay is off in all states idle BGM playback paging and intercom on while in a call the relay is normally off but when the client is in intercom state the relay automatically switches on always on off while in a call this is the inverted version of On while in a call setting The relay is normally switched on and off when the client is in a intercom state on while in PA mode the relay is normally off but when the client is receiving paging message the relay automatically switches on on while receiving audio stream the relay is normally off but when the client is receiving audio stream either in intercom or PA mode the relay automatically switches on Note Please have in mind that the BARP relay control command is ignored when the relay is not in always off mode in order not to override the preconfigured relay behaviour Default alwa
43. ng in the LAN or there could be a LAN cable issue Check device LAN cable connections eventually set firmware defaults through keeping pressed the device front panel reset button for more than 10 seconds then listen to SoniclP If the above don t solve the issue try the serial rescue process see par 6 1 Audio is missing Volume level is set to 0 mic or speakers wiring is defective Check the volume level client Audio gt Default Paging Volume master Audio gt Default Volume fields to be greater than 0 Check also mic and speakers to be well connected to the device Audio corrupted Client device has an audio format set different from the master Check Audio Format field under CONFIGURATION gt Advanced Settings gt Audio section All devices in the system MUST have the same audio format set Annuncicom 100 200 master device not working USB key is not connected to the device Insert a USB key ICCLIENT locked in PAGING state Master could have been rebooted while paging Once master is up re page locked devices and close the paging session BARIX AG 81 91 Device not responding in the serial update process Another PC task can be holding the serial port Check for other PC programs tasks using the same serial port and terminate them Restart the update procedure BARIX AG 82 91 8 Dictionary 8 1 1 8 1 2
44. ng is 1 BARP Broadcast Address By default the ICCLIENT uses broadcast to listen send on the BARP ports Modify the BARP IP address to use multicast if communication across different networks is desired or if your LAN policy is not allowing broadcast Default setting is 0 0 0 0 BARP Audio Port Enter the BARP port number where the ICCLIENT will listen for incoming audio Default setting is 5555 BARP Control Port Enter the BARP port number where the ICCLIENT will listen for BARP control messages Default setting is 5556 BARPP Status Port Enter the destination port number to which the ICCLIENT will broadcast BARP status messages Default setting is 5557 BARIX AG 43 91 Notification Port Enable here the usage of the notification port which the client may listen for any incoming audio No BARP messages are checked for this port so any audio arriving at this port will be played immediately This can be used as a Broadcast to all feature Default setting is No 3 4 2 3 Audio e Audio Format Choose between different encoding types and sampling frequencies p law or A law at 8 or 24 kHz Default setting is u law 8 kHz IMPORTANT make sure to use the same encoding on ALL devices of the ICPAGING system Acoustic Echo Cancellation Choose between On and Off Default setting is Off Note this options is visible available only for hardware that supports AEC
45. ng is u law 8 kHz IMPORTANT If you change the encoding don t forget to provide record correct unattended custom audio message files Also make sure to use the same encoding on ALL devices of the ICPAGING system Acoustic Echo Cancellation Choose between On and Off Default setting is Off Note this options is visible available only for hardware that supports AEC Input Source Choose the desired input source Default setting is Mic BARIX AG 31 91 Duplex Mode Choose the desired mode of operation Default setting is Full e Hands Free When set to yes and Half Duplex mode is enabled the talk listen mode can be voice controlled while the ICMASTER is in active call If the voice level exceeds the one set in Input Trigger Level the master is switched in talk mode and the client in listen mode The behavior for paging is also changed the Page key needs to be pressed once instead of press and hold to activate Paging mode and pressed again to stop Please see BASIC SETTINGS for keys to be used in Hands Free mode Default setting is No Input Trigger Level Triggering input audio level if Hands Free mode is selected Accepted range 0 32767 Default setting is 1000 e Inactivity timeout Sending of the audio stream in Hands Free mode stops after this number of milliseconds of no input audio signal Default setting is 1000 e Microphone Gain Microphone gain dB increa
46. nsion is connected key 17 bottom left corner to key 64 top right are assigned respectively to targets 17 to 64 The key functions are the following Key 1 accept an incoming call hang up current call If the master is in a call and another client is ringing pressing this key will hang up the current call Pressing it once again will answer to the incoming call In half duplex mode this key works as a PTT key Press and hold to answer incoming call and start talking release to listen If the handsfree mode is activated then the talk mode can be voice controlled In this case the voice activation level and the time out are configured via the web UI NOTE closing the current call when there is a second incoming call is possible only in FDX mode In HDX mode key 1 is used as a PTT key so in this case only rejecting the incoming call is possible Key 2 page all selected clients if no call is in progress trigger the connected client s relay door open for 5 seconds if a call is in progress Please note this is a PTT Push To BARIX AG 17 91 Talk button when the handsfree mode is not activated In handsfree mode press this key once to activate the paging mode and once again to stop it The key LED blinks when paging is active Key 3 pressing this key will cancel an incoming call either in idle mode or when the ICMASTER is in a call session with one client and another client is calling If the ICMASTER is
47. nt functionality In addition it has 2 lines LCD display and an IR port for remote control Exstreamer 200 205 used as client Provides stereo BGM and paging endpoint functionality In addition it has 2x25 W amplified speaker output and an IR port for remote control Annuncicom PS1 this device can be used as a client or as a two buttons master allowing to answer incoming intercom call requests and to page a predefined group of targets Group key 1 Address Map from the web configuration page Annuncicom 60 used as a client NOTE other Barix devices not in this list may or may not work correctly with ICPAGING application NOTE when Annuncicom PS1 is used as a master all features using the USB stick are disabled i e customized station ringtones unattended mode recording unattended and custom messages 1 The built in IR receiver of Exstreamer 110 200 is not accessible from BCL ABCL applications like ICPAGING can use the BARIX external IR dongle or the IR receiver of the Volume Source Control unit BARIX AG 11 91 1 4 Additional documents Technical specifications for the supported devices can be found in the corresponding product sheet which can be downloaded from our site www barix com The ICPAGING System has been developed in BCL and is distributed with its source code enabling users to further customize it if they wish to For detailed technical information about the programming langua
48. o stream a pre recorded file to the selected points The default message can be replaced in the ICgraph configuration folder Note the audio must be recorded in 16 bit mono WAV format and must have the same audio frequency than ICgraph and the devices have Start record Stop record this button allows to record running communication on ICgraph Recorded files will be displayed in Record window Recorded pagings to multiple points can be used to send later as pre recorded files to selected devices Note this function requires the installation of the MP3 libraries for more info see ICgraph manual BARIX AG 56 91 Settings this button opens on Windows PCs the Internet Explorer if a white point button was selected before then the Internet Explorer opens with the home page of the selected device 4 3 1 Intercom functionality with ICgraph In the Full duplex and in the Half duplex configurations everything is the same except the Intercom functionality To use the Intercom functionality the device must ring before to request the two way communication When ICgraph receives a Ring request from a device the according point button will change his color and blink magenta At this state select the point and click the Intercom button to get a two way communication In the Full duplex mode ICgraph configuration both sites can communicate with each other To finish the communication press the Clear All button In the Half
49. of the device sent in DHCP request If left empty a name based on the device s MAC address is generated automatically Enter up to 15 Characters Web server port Defines the port where the webserver of the device can be reached If set to 0 the default HTTP port 80 is used Default Ethernet Port On devices with dual ethernet connection this parameter selects the default port to be used In most cases selecting ETH1 is suitable however some devices e g the PS16 provide Power over Ethernet PoE functionality on ETH2 BARIX AG 28 91 If you change this parameter do not forget to connect the ethernet cable to the proper port on the rear of the device NOTE on devices with a single ethernet port select always ETH1 Selecting ETH2 makes the device inaccessible Default ETH1 SNMP System Name SNMP MIB entry for system name system sysName 0 Default empty SNMP System Location SNMP MIB entry for system location system sysLocation 0 Default empty SNMP System Name SNMP MIB entry for system contact system sysContact 0 This parameter can be queried using any SNMP browser but can not be updated Default empty 2 5 2 2 BARP Control BARP Station ID Enter here the BARP system ID of this master station The ID is used from the clients to identify the source of the control messages in multimaster environment BARIX AG 29 91 Default is 1001 e Paging Priority Ent
50. p screwdriver and set the arrow of the yellow switch to point to 1 Take a LAN cable with the necessary length and plug it in the VSC RJ 45 socket BARIX AG 68 91 Connect the other end of the LAN cable to the DSUB9 RJ45 adapter Plug the adapter in the RS 232 port at the back panel of the Exstreamer 100 screwing it for more reliable connection Reboot the Exstreamer 100 to recognise the newly connected VSC unit Now the VSC unit should be functional After reboot the default BGM channel should be displayed for ex 1 Rotating the knob left right decreases increases the volume Pressing the knob switches to channel mode the rotation changes the channel being played If channel 0 is selected then Lo meaning local line input channel is displayed 5 7 Configuring the PC for BGM distribution 5 7 1 Hardware requirements For music distribution we need a computer that can run the BARIX MP3 RTP Streamer application which creates several streams from MP3 library Any recent Windows Linux iMac computer running Java VM should work 5 7 2 Configuring the MP3 RTP Streamer Download the MP3 RTP Streamer from the BARIX web site Unzip it in a separate 2 This DSUB9 RJ45 adapter is sold separately Please contact BARIX for more information BARIX AG 69 91 directory and run the MP3_RTP_Streamer jar The application window should look like this eoo Barix MP3 RTP streamer MP3_RTP_Streamer cfg Ch
51. pplication is ICMASTER click REBOOT menu button and under the Reboot as drop down list select Intercom Client and click Reboot 5 4 2 General settings Now it is time to configure our door station As has been done for the master station once Annuncicom 200 is rebooted open CONFIGURATION and then Advanced Settings page and setup the desired options int the Network Settings section 5 4 3 Door station settings BARP Control section BARP Station ID Check the client ID to be 1 BARIX AG 65 91 Audio section Duplex Mode Choose Half e Audio section Use AI Phone Set to Yes e Background Music section BGM First Broadcast Port Playing music on Al Phone is not possible because of the two line interface that it is using so set itto 0 no BGM Click the Apply button to save the settings and reboot the device 5 5 Configuring the cash desk station 5 5 1 Initial setup Do the initial setup as described in the ICMASTER General settings section After uploading the SW if the default running application is ICMASTER click REBOOT menu button and under the Reboot as drop down list select Intercom Client and click Reboot 5 5 2 General settings Now it is time to configure our door station As has been done for the master station once Annuncicom 100 is rebooted open CONFIGURATION and then Advanced BARIX AG 66 91 Settings page and setup the desired options int the Ne
52. pport 10 100 Mbit Ethernet connection supports automatic network configuration BOOTP DHCP IPzator and as well as manual static IP configuration ICGraph PC software full or half duplex for Intercom mode BARIX AG 9 91 single or multimaster mode playing paging messages remote switching of client relay 1 3 Supported hardware The ICPAGING solution is designed to run on the following Barix devices PS16 Paging Station while it is possible to use the PS16 as a client with its 112 available keys 16 available others on separate 48 keys extension s and two line LCD display is the perfect device to be run as an ICMASTER station Annuncicom 200 can be used as a master or as a client Provides mono BGM intercom door relay control and paging endpoint functionality When used as a client the available two wire interface allows the device to use the AIPHONE door stations in half duplex mode Annuncicom 100 can be used as a master or as a client Provides mono BGM intercom door relay control and paging endpoint functionality Exstreamer 100 105 used as client Provides stereo BGM and paging endpoint functionality Exstreamer P5 used as client Provides mono BGM and paging endpoint functionality combined with 5W amplified speaker output and Volume Source BARIX AG 10 91 Control VSC port Exstreamer 110 120 used as client Provides stereo BGM door relay control and paging endpoi
53. s 0 0 0 0 In this case when the call button associated with that IP address is pressed then the call request is broadcasted to all masters and one of them may pickup The masters track the current state of the calling client status message and if it changes to something other that 3 connecting then they stop ringing The masters also stop ringing if more than 5 seconds have elapsed after the last call request command sent from the client failover scenario Configured as call all masters scenario However if there is one master in a call reject mode the client will get the reject and start calling the other masters in the list by sending unicast call requests The masters that got the broadcasted call request shall stop ringing 6 4 Understanding BARP address bitmaps According to BARP protocol the address bitmap is 128 bytes allowing to address client IDs 1 1024 starting from 1 client ID 0 is not valid In the ICMASTER application because of the limited memory space in the EEPROM only BARIX AG 77 91 the first 16 bytes can be stored thus allowing to group select only the first 128 client IDs Each byte addresses 8 clients for ex byte 0 addresses clients IDs 1 8 byte 1 addresses client IDs 9 16 etc Setting a bit within a byte enables the corresponding client clearing the bit disables it However the client IDs within a byte are stored in reversed order i e the smallest ID is stored in the MSB the
54. se if your BARIX AG 32 91 microphone is too faint decrease if it s too loud or overdriven Default 21 dB e A D Amplifier Gain A D converter preamplification in dB Increase if the audio signal too faint decrease if it s too loud or overdriven Default 0 dB Default Volume Choose between 0 and 100 in 5 steps Default 50 2 5 2 4 Incoming Call Call Master by Configures the way the master is being called If set to ID then the call is ignored if the destination ID in the call request is not the same as the one of the master When set to IP Address the master reacts on unicast or broadcasted call requests The destination ID check is ignored in this case Default is IP address Unattended Mode Enables or disables the unattended mode When enabled the Unattended Timer becomes visible and can be configured Disabling the unattended mode is recommended when using the master in a multimaster environment because if any of the masters is in unattended mode it may always BARIX AG 33 91 pickup the incoming call thus preventing the other masters to get the call When disabled pressing the unattended mode key enters the master in a Call reject mode Default is Enabled Unattended Timer Configures the number of seconds after the device switch to unattended mode during a call Minimum value allowed is 3 maximum is 60 Default is 20 2 5 2 5 Paging Group Addre
55. set to 0 is used to address the network as a whole for example in routing entries Example 192 168 0 0 Network addresses can not be used as a host address 8 1 17 Broadcast Address The address with the host part bits all set to 1 is the broadcast address meaning for every host Example 192 168 0 255 Broadcast addresses can not be used as a host address BARIX AG 87 91 8 1 18 IP Netmask The Netmask is used to divide the IP address differently from the standard defined by the classes A B and C Entering a Netmask it is possible to define how many bits from the IP address are to be taken as the network part and how many bits are to be taken as the host part Standard IP network Netmask Class Network bits Host Netmask bits A 8 24 255 0 0 0 B 16 16 255 255 0 0 C 24 8 255 255 255 0 Netmask examples Netmask Host bits 255 255 255 252 255 255 255 248 255 255 255 240 255 255 255 224 255 255 255 192 255 255 255 128 255 255 255 0 255 255 254 0 255 255 252 0 255 255 248 0 2 4 90 NO OB WP o 255 128 0 0 255 0 0 0 NN AO BARIX AG 88 91 8 1 19 8 1 20 Private IP Networks and the Internet If your network is not connected to the Internet and there are no plans to make such a connection you may use any IP address you wish However if you are not connected to the Internet and have plans to connect
56. ss Map Allows to set up the related group of destination targets Click related View Modify button to setup the group A label on the right shows the number of selected clients in this group Note only available groups supported from the current keyboard layout are displayed Default setting is starting from group 1 10 clients selected for every group for group 1 id s 1 to 10 are selected group 2 id s 11 to 20 selected group 8 id s 71 to 80 selected e Audio Multicast Socket Configures the multicast group socket as IP PORT for paging As IP it has to be within the range 224 0 0 0 239 255 255 255 If set to 0 0 0 0 then the default broadcast address is used Port is ignored if the IP is set to BARIX AG 34 91 0 0 0 0 Default is 0 0 0 0 12345 use broadcast 2 5 2 6 I O Control e Relay 1 Control Configures the relay behavior The relay can be either off always off on while an incoming call is pending relay while ringing or on while a call is in process relay while talking Default is always off e LED Status Configures the device front panel led behavior for the devices that have a led panel Default is Input State 2 5 2 7 Security Reset Function Enable or disable the Reset function on the Reset button and on the WEB Ul In order to restart the device press the Reset button once Default enabled e Factory Defaults Enable or disable the Factory D
57. stem master slave architecture BARP compatible integrates seamlessly with other BARP applications like MP3 RTP Streamer ICGRAPH BARP paging client priority based audio messaging easy WEB based configuration multiple master configuration call all masters and call failover scenarios ICMASTER full or halfduplex mode of operation handsfree mode for sending paging messages and half duplex communication upto 112 available keys with two 48 keys extensions configurable audio messages priority intercom client call master caller ID display configurable ringtones per client till 8 configurable single or group target buttons paging up to 128 devices 1 dynamic group configurable unattended mode timeout configurable call reject mode for BARIX AG 8 91 multimaster environment recordable unattended mode message recordable custom message control of local and clients volume client background music BGM channel control 10 100 Mbit Ethernet connection supports automatic network configuration BOOTP DHCP IPzator and as well as manual static IP configuration ICCLIENT full or half duplex mode of operation single or multimaster mode playing paging messages intercom to master supports the HAI Volume Source Control unit and IR remote control background music BGM playback and control background music playback in mp3 format AIPHONE door panels su
58. t the according sub directory and start the ICgraph jar file from this directory ICgraph can be used as single master or together with other Masters but in multimaster mode the behaviour is a little bit different than using the ICMaster devices 4 3 Usage of ICgraph The ICgraph configuration shows per default 8 groups or 80 client configured with Ids from 1 80 and some more function buttons You can change the view and display group buttons and or point buttons Illustration 8 ICgraph application Full duplex Will Barix graph Intercom V 2 0 5 2012 06 06 inixi Fullduplex Intercom Master Station 12 07 13 08 16 21 B fl n XI Intercom Showgroup Show member Show member Show member Show member Show member Show member Show member L T ot LL LS LE LN LS LL LN Start Paging bae devices Mute ON a Relay open Menu OFF Show events Show LOG Show records Play message Start record Settings ICpaging Fdx v1 0 BARIX AG 54 91 When ICPaging devices in the network are properly configured then they will be discovered after maximum 30 seconds from ICgraph and the according point button will change the color from dark grey to white The white point buttons can be used for other actions on ICgraph If a device is not more reachable in the network e g turned off or not connected then the point button will change
59. twork Settings section 5 5 3 Cash desk settings BARP Control section BARP Station ID Set the client ID 2 Click the Apply button to save the settings and reboot the device 5 6 Configuring the stereo music player 5 6 1 Initial setup Do the initial setup as described in the ICMASTER General settings section After uploading the SW if the default running application is ICMASTER click REBOOT menu button and under the Reboot as drop down list select Intercom Client and click Reboot 5 6 2 General settings Now it is time to configure our door station As has been done for the master station once Exstreamer 100 is rebooted open CONFIGURATION and then Advanced Settings page and setup the desired options int the Network Settings section In addition also set the serial port to be used BARIX AG 67 91 5 6 3 5 6 4 unit for the VSC 1 0 Control section Serial Port Select VSC Panel BGM player settings BARP Control section Station ID Set the client ID 3 Background Music section BGM Broadcast Address Set to use multicast address 224 1 2 4 Background Music section BGM First Broadcast Port Set to 10501 Background Music section Available BGM Channels Set to 3 Background Music section BGM Start Channel Set to 1 Connecting the Volume Source Control VSC Unpack the VSC unit from the supplied box Turn it upside down Take a small flat ti
60. ys off LED Status Configures the device front panel led behavior for the devices that have a led panel BARIX AG 51 91 Default is nput State 3 4 2 8 Security This section is the same as in ICMASTER See ICMASTER 2 5 2 7 Security section BARIX AG 52 91 4 Running lCgraph 4 1 About ICgraph ICgraph is a Java based PC software It requires a Java Runtime Environment JRE installed on the PC to run properly Such JRE is available for almost all operating systems see www java com ICgraph is a free Barix software when used together with Barix hardware products This software is freely configurable over the ICgraph cfg file It allows to control ICPaging devices and communicate to it The ICPAGING firmware package contains two different ICgraph configurations one for half duplex and one for full duplex These configurations can be modified from you if needed For more information about ICgraph check the ICgraph manual available on www BARIX com 4 2 How to run lCgraph The ICPAGING software package contains a sub folder ICgraph Master there are two different ICgraph configurations stored one for full duplex and one for half duplex Before you can start ICgraph make sure the Java JRE is installed see www java com on your PC If Java is installed then decide which mode BARIX AG 53 91 full duplex or half duplex you will use for Intercom communication with the clients and selec