Air-AlArm D.i.Y. Wireless Home AlArm sYstem Kit User mANUAl
Contents
1. Air Alarm Securinybts LLC kabo Wide Angle t Motion Sensor Wireless Door Window Sensor Wireless Remote Controllers Alarm Host AE Wireless Indoor Siren Copyright Notice This manual is furnished under license and may be used or copied only in accordance with the terms of such license Except as permitted by such license no part of this publication may be reproduced stored in a retrieval system or transmitted in any form or any means electronic mechanical Recording or otherwise including translation to another language or format without the prior written permission of SecurityMan The content of this manual is furnished for informational use only is subject to change without notice and should not be construed as a commitment by SecurityMan SecurityMan assumes no responsibility or liability for any errors or inaccuracies that may appear in this book All other product names trademarks and registered trademarks in this document are the properties of their respective holders FCC Information Notes on FCC s Consistent Statement of Information This product meet the requirements specified in Part 15 of FCC Regulation Operation rests with the following two conditions 1 The equipment should not cause any harmful interference 2 The equipment must receive and process any interference including any possible interference caused by operation mistakes Warranty SecurityMan warrants this pro
2. Press the AWAY button to arm before leaving home and press the DISARM button to disarm Press the HOME button to part arm or 1st defense line enabling to protect the perimeters of home at night time before going to sleep Please replace the batteries within 2 years of usage or any time when it becomes less sensitive or shorter controlling distance Adding amp Cancelling Remote Controllers B 5 SecurityMan To Add Press SET Password ENT_then _70 ENT 00 ENT the Learn light will appear solid red Press any button on remote controller twice consecutively the alarm host will beep in series and the Learn light flashes five times and then turns off to indicate the remote control has been successfully added To Cancel Press SET Password ENT_then _71 ENT 00 ENT the alarm host will beep in series then the Learn light flashes once and then turns off to indicate the remote control has been successfully cancelled Note The alarm host can only learn 1 remote control at a time a total of 8 remote controllers can be added to a host Wireless Door Window Sensor SM 87B Mounting Holes Mounting Bracket LED j Emitting Sensor lt Battery Compartment For Mounting Holes please use screw C or adhesive sticker see page22 For Mounting Bracket please use screw D Magnetic underlay mount use for uneven surface see page22 Functions Features Mainly d
3. N A 2nd Defense Line Indicates the second detecting defense areas areas such as living room aisles bedrooms hall ways and etc These zones are generally composed of the wireless wide angle PIR sensors where it can detect movements in open spaces 24 hour Defense Line Indicates the detecting defense areas in a 24 hour monitoring statue commonly used in areas such as emergency distress medical rescue gas leakage fire alarm and etc These zones are generally composed of panic buttons wireless gas sensors N A and wireless smoke sensors SecurityMan Programming the Alarm Host SM 8088E Function Operation Operation Explanation Notes 1 The alarm host will automatically exit from the programming status if inactive for 20 seconds 2 Programming is effective after _SET Password ENT_ use ESC button to go to previous step 3 The alarm host will beep in series to indicate the operation is successful and beep once to indicate operation failure _ _ SET Password ENT__ This command applies throughout whenever programming the alarm host before attempting to change other programming features such as Delay Time to Arm Delay Time to Alarm Emergency Alarm Voice Adding and Cancelling wireless devices and etc For example to change Delay Time to Arm below from default 40 seconds to 1 minute press_SET 888888 ENT_ follow by _15 ENT_ The programming default password is 888888 6 digits long _Input Alarm Telephone Number_
4. and slide the power switch to On Power down mode may be in affect 5S detect once every 5 seconds 5MIN detect once every 5 minutes please refers to the user s manual for PIR setup Weak battery power not switched on or the PIR motion detector is in the power down mode The detecting distance of PIR motion sensor gets shorter The alarm host does not alarm after the new added wireless detector is triggered When the ambient temperature in the The ambient temperature in the detecting detecting area exceeds the human body area is too high temperature the detecting distance will get shorter it s normal Failed to follow the operation instruction Follow the operation instruction of of Adding and Cancelling sensors devices Adding and Cancelling to activate the of newly added wireless sensor s new wireless sensor s The PIR motion sensor flashes frequently in green Replace with new battery of the same Battery is drained or low gt 4 voltage specification The door window sensor indicator flashes freguently in green after alarming The distance of the remote controller gets shorter Replace with new battery of the same voltage specification Battery is drained or low Replace with new batter of the same volt Battery is drained or low BO age specification SecurityMan Daily Maintenance and Care This alarm system is hi tech with outstanding design and so
5. After the the alarm host will resume to be armed x is pressed Note the is required to use in order to stop the alarm host from continuing to dial the next enlisted telephone numbers D Hang up the telephone without any command the host will end the call and automatically continues to dial the next enlisted alarm telephone numbers SecurityMan Long distances arm by phone 30 seconds after successfully dial the telephone number of alarm host there will be a beep gt enter programming password of host gt beep gt enter 1 gt beep and the host will then automatically hang up after the last beep to successfully complete the operation Note Long distance arm by phone reguires the alarm host to be armed or in the Away mode Long distances disarm by phone 30 seconds after successfully dial the telephone number of alarm host there will be a beep gt enter programming password of host gt beep gt enter 0 gt beep and the host will then automatically hang up after last beep to successfully complete the operation Alarm dialing mode After the alarm host triggered or goes off the alarm host will starts to dial the first enlisted telephone number then the second third fourth and so on Unless one of the enlisted telephone numbers answers otherwise this routine auto dial will continues for three times Alarm priority If the telephone line is busy when the alarm host goes off the alarm host will take priority and it will au
6. _XX ENT Telephone Number ENT__ XX indicate telephone group number which can be of personal numbers or management center See group details below 01 Group 1 02 Group 2 03 Group 3 04 Group 4 05 Group 5 06 Group 6 personal teleohone number personal telephone number personal telephone number personal telephone number personal telephone number reserved for CID Protocol number for management center not for personal numbers requires monthly fees ea a ae Delay Time to Arm XX ENT__ Setup a dwell time in which the alarm will become activated or armed Enter 10 for XX to setup Delay Time to Arm for 40 seconds enter 15 to setup Delay Time to Arm for 1 minute and press the ENT button to confirm The default setting is 10 or 40 seconds alarm dwell time Delay Time to Alarm XX ENT Setup a dwell time in which the alarm will sound or trigger Enter 20 for XX to setup immediate alarm sound triggering enter 21 to setup a 15 seconds Delay Time to Alarm The default setting for Delay Time to Alarm is 20 Emergency Alarm Sound XX ENT Enter 30 for XX to disable Emergency Alarm Sound enter 31 to setup audible alarm sound the default is 31 During the emergency Alarm Sound is disabled or set to 30 the alarm host will operate normal and will continues to dial the enlisted phone numbers in case of emergency _Alarm Sound for 1st and 2nd defense line_ XX ENT__ Enter 40 for XX to disable alarm sound for 1st amp 2nd defe
7. varies on usage Usually installed to ceilings of living room aisles etc Specifications Operating power 9V Battery Recommend alkaline battery Wireless Transmitting distance gt 300ft in open area SecurityMan Service life lt 2 years Monitor volume 60ft Adding and Cancelling Smoke Alarm To Add Press SET Password ENT_then _70 ENT XX ENT The Learn light will appear solid red Note The XX indicate group number of the 24 hours defense zones including zone 01 through zone 05 Press the Test Button twice consecutively to trigger the smoke alarm sensor the alarm host will beep in series the Learn light will flash five times and then turns off to indicate the smoke alarm sensor has been successfully added To Cancel Press SET Password ENT_then _71 ENT XX ENT The alarm host will beep twice the Learn light flash once and then turns off to indicate the smoke alarm sensor has been successfully cancelled Note The alarm host can only learn 1 wireless device Smoke Alarm Sensor at a time a total of 4 wireless devices Sensors to a zone group can be added If 1 device is removed from a group that has 4 devices then all 4 devices in the group will be automatically removed and each device s will have to be added again to the alarm host Wireless Outdoor Siren SM 103 optional Hanging hole Speaker Study button red Backup battery on off button green Fi
8. Host SM 8088E 2 Alarm Host Specifications SM 8088E 3 Three types of Defense Line 3 Programming the Alarm Host SM 8088E 4 How to change programming password 5 Operation 5 Understand and Setup Wireless Accessories 8 Wireless Remote Controllers SM 88X 8 Wireless Door Window Sensor SM 87B 9 Wireless Wide Angle PIR Motion Sensor SM 80 11 Wireless Indoor Siren SM 103W 13 Wireless Smoke Alarm SM 93 optional 14 Wireless Outdoor Siren SM 103 optional 15 Wireless Panic Button SM 89 optional 17 Air Alarm Defence Zone Code Chart 19 Wireless Default Zone Code Chart 19 Common Problems and Solutions 20 Daily Maintenance and Care 22 Accessories 22 SecurityMan Introduction SecurityMan Air Alarm is a state of the art wireless alarm system kit for homes and businesses It is user friendly easy to use protecting homes businesses at a minimum cost of investment Do lt Your Self installation and monitoring alarm system without monthly fees is a key benefit for users The system will alert by phone calls to owner through a series of enlisted phone numbers The owner can then dial into the host to armed or disarmed using the phone s numeric keypad Air Alarm system can be upgraded by adding up to 60 wireless sensors sirens and up to 8 remote controllers Package Contents 1 x Air Alarm host with built in LEDs keypad and speaker 1 x Host Anchor Card for Fixed Position 1 x 12VDC Power Adapter 1 x Wireless Wide Angle PIR Moti
9. Recommend alkaline battery Wireless Transmitting distance gt 450m in open area Service life lt 2 years B 5 SecurityMan SecurityMan Detection Area 110 10X10m Installation and Usage Mount the bracket to a desired wall surface location or corner at a height of about 6ft to 7ft above the ground Open the sensor cover and connect a 9VDC battery Next refers to the diagrams above to adjust and select the Jumper Line timer between 5S or 5MIN for the motion sensor to detect once every 5 seconds or the sensor to detect once every 5 minutes Recommended to use 5S default setting for normal use Skip To Add motion sensor below for newly added motion sensor before closing the sensor cover and proceed to the next step Match the grooves of the sensor to the bracket and slide the motion sensor down from top to bottom to secure Adjust the sensor to a proper angle and then slide the power switch located on the side to the ON position The motion sensor takes 30 seconds to become active for operation normal working state after switching ON A red light will flashes for motion detection a frequent green light flashes mean it is time to replace the battery Adding and Cancelling PIR Motion Sensor To Add Press SET Password ENT_then _70 ENT XX ENT The Learn light will appear solid red Note The XX indicate group number of the 2nd defense zones including zone 11 through zone 15 Press t
10. ck test and secure the incom ing telephone line or use other standard phone to test the line to ensure working status The telephone incoming line has not been connected not well connected or short circuit The alarm host cannot record or partially records Slide the record switch to the ON po sition Securely press and hold down the RECORD button during recording Speak up close to the rear speaker of the host The record switch is not turned on The Record buttons not presses down and hold while attempting to record or not held down all the way Repeatedly receiving the alarm telephone The alarm host does not sound the alarm after the detector triggered the alarm in armed mode After answering the alarm phone calls and hearing the recorded message please advanced to page 5 Telephone Alarm of this user s manual as a reference to try to resolve this problem See page 5 Telephone alarm Failed to operate according to the opera tion instruction of the telephone alarm 1 In Armed Home mode make sure the sensor or wireless devices triggering is not in the 2nd Defense Line 2 Ensure the sensor detectors are not active within the system setup Entry Delay Time or Exit Delay Time 1 Caused by the functions of armed Away or Armed Home 2 Have already setup time for Entry Delay or Exit Delay The PIR motion sensor does not work Open the sensor shells to install the battery
11. d and each device s will have to be added again to the alarm host SecurityMan Air Alarm Defence Zone Code Chart Defense Zone Code Defense Zone Type Bypass Zone Delay Time to Alarm Compatible Accessories Remark Wireless Remote Controller 00 No No amp Wireless Remote Control Up to 8 RC Keypad Wireless Smoke Alarm 1to5 24 hour Defense Line No No Wireless Gas Alarm amp Panic button Each defense one support Yes zone 11 Wireless Door Magnet amp i upp 6to 10 1st Defense Line Yes up to 4 wireless to15 Wireless Curtain PIR Sensor devices Yes zone 6 to Wireless Wide Angle PIR 11 to 15 2nd Defense Line Yes 10 Motion Sensor Manufacturer Wireless Default Setting Wireless Remote Wireless Door Wireless Wide Wireless Curtain Wireless Gas Wireless Panic Sensor Type Control Window Sensor Angle PIR Motion PIR Sensor N A Alarm N A Smoke Alarm Button Sensor The default Defense 00 06 11 Zone Code Note If after setup the alarm system becomes uncontrollable or abnormal please remove or cancel all of the default setting of wireless devices such as the remote control door window sensor wide angle PIR motion sensor smoke alarm and then add re program them back into to a desired defense zone code Common Problems and Solutions Problems The alarm host sounded off immediately after connecting the power B 5 SecurityMan Possible Cause Solutions Double che
12. duct will be free from defects in materials and workmanship for period of time specified on the product packaging This limited warranty shall commence from the date of purchase SecurityMan Products warranty is not transferable and is limited to the original purchaser If the product is found to be defective then as your sole remedy and as the manufacturer s only obligation SecurityMan will repair or replace the product This warranty shall not apply to products that have been subjected to abuse misuse abnormal electrical or environmental conditions normal wear and tear or any condition other than what can be considered normal use Limitation of Liability The liability of SecurityMan arising from this warranty and sale shall be limited to a refund of the purchase price In no event shall SecurityMan be liable for costs of procurement of substitute products or services or for any lost profits or for any consequential incidental direct or indirect damages however caused and on any theory of liability arising from this warranty and sale These limitations shall apply not withstanding any failure of essential purpose of any limited remedy SecurityMan 4601 E Airport Drive Ontario CA 91761 USA Tel 888 977 3777 or 909 230 6668 Fax 909 230 6889 Email info securitymaninc com Website http www securitymaninc com Copyright 2008 by SecurityMan v4 0 TABLE OF CONTENTS Introduction 1 Package Contents 1 Main Features 1 Alarm
13. ecifications Operating power 23A 12V Battery Recommend alkaline battery Wireless Transmitting distance gt 450ft in open area SecurityMan Service life lt 2 years Installation and usage Installed in living rooms bedsides carry along etc For emergency use scared away intruders sends out emergency signal to alarm host to sound off the siren s This is a 24 hours standby zone for panic or emergency use only Please change the battery when the signal distances become shorter or every 2 years Adding and Cancelling Panic Button To Add Press SET Password ENT then _70 ENT XX ENT The Learn light will appear solid red Note The XX indicate group number of the 24 hours defense zones including zone 01 through zone 05 Press the Alarm button twice consecutively the alarm host will beep in series the Learn light will flashes five times and then turns off to indicate the panic button has been successfully added To Cancel Press_SET Password ENT_then _71 ENT XX ENT The alarm host will beep twice the Learn light will flash once and then turns off to indicate the panic button has been successfully cancelled Note The alarm host can only learn 1 wireless device Panic Button at a time a total of 4 wireless devices Panic Buttons to a zone group can be added If 1 device is removed from a group that has 4 devices then all 4 devices in the group will be automatically remove
14. etect open close states of doors and windows generally set as a 1st Defense Line or perimeters If any doors or windows are opened it will transmit the alarm signal to notify the alarm host SecurityMan Specifications Operating power 23A or 27A 12V Battery Recommend alkaline battery Wireless Transmitting distance gt 450ft in open area Service life lt 2 years Alarm Distance lt 4cm Installation and Usage Mount the magnet or smaller piece onto the door in a position of about 5 6ft above the ground to prevent any child ren from pampering Use the included mounting bracket if the door and the door frame are un even or not flush Mount the emitting or larger piece onto the door frame ensure the magnet piece and the emitting piece are even or flush The spaces between the two should be less than 10mm in gap Replace the batteries if the red LED light flashes frequently Adding and Cancelling Door Window Senor To Add Press_SET Password ENT_then _70 ENT XX ENT The Learn light will appear solid red Note The XX indicate group number of the 1st defense zones including zone 06 through zone 10 Triggers the Door Window magnet twice consecutively the alarm host will beep in series and the Learn light flashes five times and then turns off to indicate the magent door window sensor has been successfully added To Cancel Press SET Password ENT then _71 ENT XX ENT The alarm host will beep
15. he Learning Emitting Switch twice consecutively to trigger PIR sensor the alarm host will beep in series and the Learn light flashes five times and then turns off to indicate the PIR motion sensor has been successfully added To Cancel Press SET Password ENT then _71 ENT XX ENT The alarm host will beep twice then the Learn light flashes once and then turns off to indicate the PIR motion sensor has been successfully cancelled Note The alarm host can only learn 1 wireless device Wireless Wide Angle PIR Motion Sensor at a time a total of 4 wireless devices PIR Motion Sensors to a zone group can be added For example for the 2st defense line if 4 sensors were to be add ed to zone group 11 through zone group 15 it total 20 sensors in all If 1 device is removed from a group that has 4 devices then all 4 devices in the group will be automatically removed and each device s will have to be added again to the alarm host B 5 SecurityMan Wireless Indoor Siren SM 103W Learn Button Siren LED Light Indicator Functions Features Wireless receiving indoor alarm siren spot alarm sound and flashes Plugs into wall outlets for indoor use only Specifications Operating Power 100 240VAC Wireless Receiving distance gt 300 ft In open area Siren Sound 105dB Installation and Usage Plug the wireless indoor siren into a power outlet Recommendated to install 4 5ft high from the grou
16. larm Host SM 8088E LED Display 7 a _ Away __ Home Power Light Alarming Light Lower Voltage DIE Recording Light ANT POWER IN TEL OUT ON OFF ON z a 7 M N A Program Record Play 7 Emergency Number Esc Disarm Confirm Lock LCD model only Antenna Power In Out Speaker back side Mic DC or Battery Record mode In off mode the alarm host will still operate normal if the A c power is connected For wall mount please use screw B see page22 SecurityMan Alarm Host Specifications SM 8088E Operating power 9 15VDC Static current lt 60mA Alarm current lt 380mA Operating environment Temperature 10 50 C Humidity lt 80 Maximum available quantity of remote controllers 8 PCS Maximum available quantity of wireless sensors 60 PCS Dimensions 180X120X38 mm Rechargeable battery Ni Mh 4 8v 600mAh up to 8hrs long Speaker siren 100dB built in Three types of Defense Line Types of Defense Line and what they mean 1st Defense Line Indicates the first detecting defense areas or the perimeter zone such as doors and windows This is the perimeter areas where thieves initiate when attempting break in These zones are generally composed of wireless door magnet sensors and wireless curtain PIR sensors
17. mming password _SET 999999 ENT Six Digital New Programming Password ENT Six Digital New Programming Passwords ENT__ Press SET button the programming LED will light on enter 999999 press ENT then input a new six digital programming password press ENT re input the new six digital programming password and then press ENT to complete the programming password change Notice the programming LED light will disappear after the final ENT is pressed Operation To Record a voice message greeting Slide the switch on the left side of the alarm host to the RECORD ON press and hold the microphone 2 button speak close into the rear side speaker of host and then release the microphone 2 when finish with voice message greeting Voice message greeting can be anywhere between 0 9 seconds long To Playback the recorded voice message greeting Slide the switch on the left side of the alarm host to DC ON press and SecurityMan hold the playback b button to playback the recorded voice message greeting One key Arm By Remote controller Press the AWAY All Alarm or the HOME Part Alarm button on the remote control to arm and the alarm host will beep once to confirm the operation is successful See Wireless Remote Controller on page 9 for more detail By Keyboard on alarm host Press A All Alarm or VY Part Alarm button the alarm host will beep once to confirm the operation is successful One key Disarm By Remote c
18. nd Adding and Cancelling Indoor Siren To Add After connecting the siren to the power outlet press the Learning button located on the left side of the siren and the siren light will come on 3 B 5 SecurityMan Press theg button on the alarm host remote control not applicable to sound off the sirens then disarm by using the alarm host keypad by pressing _ESC Disarm programming password ENT_ the alarm host will beep twice to indicate the indoor siren has been successfully disarmed The light on the siren will flash 5 times to indicate the indoor siren has been successfully added To Cancel After connecting the siren to the power outlet press and hold the Learn button located on the left side of the siren for 5 seconds the light on the siren will flash once to indicate the indoor siren has been successfully cancelled Note The alarm host can only learn 1 wireless device Indoor Siren at a time multiple wireless sirens can be added to a host When adding or cancelling wireless sirens only operate using the alarm host keypad do not use the remote controllers to disarm in the process Wireless Smoke Alarm SM 93 optional W Working Light O Air Vents Test Learn Button 0 0 00 m Bracket Please use screw F for mounting bracket see page22 Functions Features Monitor and control fire risks for indoor use only generally set as a 24 hours Defense Line Replace the battery every 2 year
19. nse line ZZOZ M SecurityMan enter 41 to enable Audible alarm the default is 41 During the Alarm Sound disabled or set to 40 the alarm host will operate normal and will continues to dial the enlisted phone numbers upon alarm trigger Telephone Disconnection Alarm XX ENT Enter 60 for XX to disable Telephone Disconnect Alarm enter 61 to enable Telephone Disconnect Alarm the default is 61 Telephone disconnection Alarm is line of integrity alarm To upload arm disarm to management center XX ENT Enter 50 to disable upload enter 51 to enable upload to management center the default setting is 50 or disable Leave this disable if management center is not in service User Code 80 ENT XXXX ENT__Enter an integers between 0000 9999 for XXXX to setup user code for management center The default is set as random apply to management center use only To Setup User Code SET 999999 ENT press A VY button ENT enter programming code ENT 6 digits user s code ENT re enter user s code ENT_ press SET and programming will appear enter 999999 press ENT and then press A V page up down to choose revise user s code and press ENT reenter new programming code press ENT and then enter 6 digits user s code and press ENT Note user s code cannot be same as master code of 999999 and programming code Press ESC to exit from the programming when finish How to change progra
20. on Sensor with Mounting Bracket Battery Included 1 x Wireless Magnetic Door Window Sensor with Mounting Bracket Battery Included 1 x Wireless Indoor Siren 2 x Wireless Remote Controller Battery Included 1 x Phone Cable 3ft 1 x Warning Sign 1 x User s Manual Accessories on page 22 Main Features Easy to use and cost effective D l Y do it yourself wireless intruder alarm system kit Supports up to 60 wireless sensors 15 wireless defense zones and 4 wireless sensors per zone Transmit at 430 433MHz frequency band wireless transmitting distance up to 300 feet remote controller smoke sensor and siren and up to 450 feet magnetic door window sensor amp PIR motion sensor Supports up to 5 phone numbers for auto alarm call and 1 management center protocol CID Armed disarmed by remote controller phone call or host s keypad Easy one key armed disarmed operation Programmable silent alarm or audible alarm B 5 SecurityMan Recordable alarm voice message up to 9 seconds record time Telephone line disconnection alarm sound every 5 seconds Smart 3 defense lines configuration 1st defense line is the perimeter 2nd defense line for in room amp 24 hour defense line Internal rechargeable backup battery in alarm host last up to 8 hours Battery included for remote controllers wireless door sensor and wireless motion sensor last up to 2 years Programmable password Ademco CID compatible protocol A
21. ontroller Press the DISARM button on the remote control to disarm the alarm and the alarm host will beep twice to confirm the operation is successful Disarm by keyboard on alarm host ESC Disarm Programming Password ENT__ Press the ESC Disarm button follow by the programming password and then ENT to disable alarm siren using the alarm host The host will beep twice to confirm the operation is successful Emergency Panic Distress By Remote controller Press the EMERGENCY button on the remote control at times of an emergency to immediately activate the sound siren on the alarm host and wireless sirens By Keyboard on alarm host Press the EMERGENCY 4 button on the alarm host at times of an emergency to immediately activate the siren sound on the alarm host and wireless sirens Telephone alarm After receiving the phone call from the alarm host the recorded voice message will repeatedly plays for 22 seconds Before the 22 seconds expires the following action must be taken A Press the number 8 on the phone pad to extend the time intervals for an additional 20 seconds to enter the listening state In the listening state the built in microphone on the alarm host will be active to pick up any sound that takes place near by the alarm host B Press the pound button to immediately replay the recorded voice message C Press the star button the host will end the call and stop to dial the enlisted alarm telephone numbers
22. phisticated product which should be used carefully To make the alarm system operable in long terms and to stably prolong the service life the follow are strongly recommended 1 Installed alarm system and alarm host in the dry and well ventilated places 2 Do not put the alarm host and any wireless sensors in cold hot or dusty places to prevent it from shortening the life of electric parts preventing the plastic shell from distorting and accelerating to age 3 Do not install the wireless alarm system in low easy to reach and exposed places to prevent the children from pampering with or thieves easy access 4 Regular scheduled testing is necessary to help prevent system failures and resolves problems in time 5 Check batteries in all wireless sensors and replace them as needed to ensure normal operation 6 Power off and remove all batteries from all wireless system before storing them on shelves Accessories For the warning sign For the alarm host For the alarm host For the PIR nd nq VV aa 25mm IRRERRRERENI 25mm 20mm z lt A E nnd AT a lt T lt auuuuuuuu lt n m 3 3 D annum N i 3 3 Add on optional Adhesive sticker For the smoke sensor For the outdoor siren For the panic button 25mm i 6a 35mm Ba gt sunning AV an naj E 3 3 VA NENEY www securitymaninc com
23. present charging status The rechargeable battery takes approximately 20 hours to be fully charged and then the charging indicator light will turn off Activating and deactivating Outdoor Siren To Activate i SSS SSS PE A P SecurityMan Siren Connect the siren to an AC power outlet gt press the red Study button located on the back of the siren gt the red siren lights will turn ON Alarm Host Press 4y emergency button on the alarm host to sound off the alarm and then disarm the alarm by using the _ESC Disarm programming password ENT_ the alarm host will beep twice to indicate the outdoor siren has been successfully disarmed The light on the siren will then flashes 5 times to indicate the outdoor siren has been successfully added Note One siren can be studied at a time up to 10 wireless alarm sirens to a host To Deactivate Press and hold the Study red button for 10 seconds the siren will flash once to indicate the Outdoor siren has been success ful deactivated Wireless Panic Button SM 89 optional f 8 Indicator Light O Emergency button NZ Lb Lb Battery cover anode cathode CA o I See To mount please remove the back cover and use screw H see page 22 Functions Features Used for emergency panic generally set as a 24 hours Defense Line Placed under tables besides bed whenever panic is needed Replace battery every 2 years varies on usage Sp
24. tomatically cut off the busy used line to resume automatic dial to the enlisted alarm telephone numbers to convey the crime Telephone line disconnection Alarm If the telephone line is cut or comes off the hook the host will beep every 5 seconds after the telephone line are cut off or disconnected It will continue to beep until the phone line are fixed or reconnected AWAY mode In this state after any detection in the 1st 2nd or 24hrs defense line is triggered the alarm host will immediately sound the sirens and at the same time automatically dial the enlisted alarm telephone numbers in sequence HOME mode In this state after any detection in the 1st or 24hrs defense line is triggered the alarm host will immediately sound the sirens and at the same time automatically dial the enlisted alarm telephone numbers in sequence In HOME mode the 2nd defense line will be disabled and cannot be triggered SecurityMan Understand and Setup Wireless Accessories Wireless Remote Controllers SM 88X Disarm Away H Il f Home m Emergency Functions Features Used to armed amp disarmed alarm host Emergency button for emergency or panic help Specifications Operating power 27A 12V Battery Recommend alkaline battery Wireless Transmitting distance gt 300ft in open area Service life lt 2 years Installation and Usage Ideal for keychain and to take with when the alarm host is in the AWAY mode
25. twice then the Learn light will flash once and then turns off to indi cate the magnet door window sensor has been successfully cancelled Note The alarm host can only learn 1 wireless device Magnet Door Window Sensor at a time a total of 4 wireless devices magnetic sensors to a zone group can be added For example for the 1st defense line if 4 sensors were to be added to zone group 06 through zone group 10 it total 20 sensors in all If 1 device is removed from a group that has 4 devices then all 4 devices in the group will be automatically removed and each device s will have to be added again to the alarm host Wireless Wide Angle PIR Motion Sensor SM 80 021 Working Light O rz s O u On Off switch Low Votage Light i Power Switch Roy Orr p On Sensor Window O O Learning Emitting Switch m Jump Line Install the bracket Fix the PIR by pushing Keep the switch on it downwards Please use screw E to install the bracket see page22 Functions Features Mainly monitor and control indoor stereoscopic spaces generally set as a 2nd Defense Line When human body enters the detection areas the motion sensor will transmit the alarm signal to the alarm host It is immunity to pets cats dogs etc that are less than 10KGS will not cause false alarm Specifications Operating power 9V Battery
26. xed screw hole Please use screw G to mount see page22 B 5 SecurityMan Functions Features Nice exquisite and weatherproof Micro computer controller steady performance and quality Study up to 10 pieces to a host Built in rechargeable battery for backup automatic switches between AC powers to DC power in cases of emergency outage Low standby power consumption low battery voltage LED detection resumes charging automatically Wall mountable installation Specifications Operating power 110 240VAC_50Hz Static power consumption lt 40 mA Working power consumption lt 450 mA The maximum alarm sound duration with flash 3 Minutes Receiving distance gt 300ft in open area Built in Rechargeable battery 6VDC 1300mA up to 100 hours stand by Alarm Siren Sound gt 120dB IP51 Installation and usage Plug in the AC power to an outlet press the green button to enable the backup battery located on the back side of the outdoor siren Study the siren to the alarm host according to the activation and deactivation instructions below Unplug the siren from the AC power plug after finish studying and find a proper location Outdoor indoor to mount it and then plug in the AC power The alarm sound and red LED flash last up to 3 minutes if the alarm host is not disarmed within the 3 minutes increment When the backup battery has a voltage that is equal to or less than 5VDC the charging indicator solid red light will come on to re