Home
PrecisionID USPS Postnet Font User Manual
Contents
1. EEE a 1 a Formatting Fc v Allow Dockin Hide 3 Give your formula field a name in this example we will name it PrecisionID Barcodel In versions 9 and above if you are asked to use the editor or the expert choose Use Editor 4 Inthe Formula Editor choose Functions Additional Functions and select the PrecisionlD PNET function The U25PrecisionID dll UFL file must be installed before you can use this formula or you will receive an error This UFL file is installed by running the Setup exe file in the font package The U25PrecisionID dll file is also provided in the Crystal DLL folder of the Zip file To manually install it copy it to the Windows System directory or the directory where the Crystal DLLs are located When the U25PrecisionID dll file is installed and active the PrecisionID formulas will appear in the Formula Workshop under Additional Functions 5 Place the cursor between the parentheses in the formula and select the field you wish to encode in the barcode from the Report Fields area in the Formula Editor A correct formula will appear something like PrecisionID_ PNET Table1 Field1 where Table1 Field1 is the table and field of your database The tables and fields should be visible above in your database connection Choose Save and Close From the Field Explorer drag the PrecisionID Barcodel Formula Field to the report 8 Choose File Print Preview You should see that the formula fiel
2. Library Fonts folder of your hard drive To activate the fonts restart the application some applications may reguire a restart of the computer Other operating systems We supply Windows TrueType TTF fonts as well as Binary PFB and ASCII PFA versions of PostScript fonts Consult the documentation for your operating system about instructions and which font to install Using the fonts to create bar codes If your source data already includes the required MOD10 check digit all you have to do is append the parenthesis to the beginning and ending of the data for example 123451234122 In this case you do not need to use our PrecisionID Font Formatting Components TM The complete Postnet barcode consists of the start stop character zipcode data 12345123412 a check digit 2 and the start stop character The result should look something like this 123451234122 If your check digit is not already included in your data we recommend using the PrecisionID Font Formatting Components which automatically calculate the required Start Stop and MOD 10 check characters and simply return the text that is formatted to the barcode font When this text is printed with our barcode font a correct barcode is created To calculate the check digit manually we suggest following the Visual Basic source code we provide This code is located in the Examples VB Module folder of the package Tutorials for Specific Applications T
3. PrecisionID Postnet Barcode Font User Manual Notice When you use this product you agree to the End User License Agreement EULA The EULA is provided as a file in the package for this product To view the license online please visit www PrecisionID com licenses Limitations of the demo version The demo version of this product may be used for evaluation purposes only In the demo version the number 7 and other special characters such as FIM codes contain the demo watermark All other characters and symbols are exactly the same as the purchased version If you are using the demo version and you would like to order please visit http www precisionid com Postnet Symhbolosy OVE V CW vccccsisscscsccouicscsneiscrssconscacencsseseniesedseseonassdenwassonntoptasshensdeassnibensaenucasenevedenscascaes 1 Praduci VE VIEMW RENE OE ao 1 d St ANNA LOJ nine as a a ra o 2 Microsoft WV NAO WS silno o 2 Macintosh OS l N n ee 2 Gihstoperal no VSC zsse ds s tkan hv lot una nov roka ak nooo E ra ooo 2 Using the fonts ta create Dar CodeS sssss asokos sadne o mienne 2 Tutorials for Specific Applications s s siissvk vc kikopud vodov vk bv Voznica lava 2 Microsoft ACCESS u rn 3 Microsoft EXC nent ina os po vic ran Zn k 3 Microsoft Word Mail Mero nano o cv a i nr a 4 Crystal Reports saioari esses o BA dak 4 Information for Specific Implementations sosssesssessseoesoossoosssossssesssocssoossossssossssessseessoosssosssosss
4. ch PrecisionID Postnet Normal Postnet Font PrecisionID Postnet L Postnet Font 15 lighter use on printers that print darker than normal PrecisionID Planet Normal Planet Font PrecisionID Planet L Planet Font 15 lighter use on printers that print darker than normal Our PrecisionlD PNET function may also be used to calculate the check character for the Planet barcode because the check character calculation is the same as a Postnet barcode FIM and other Postnet related bar codes types Our Postnet fonts include FIM and other Postnet related bar codes types in the Postnet font including Business Reply Mail and OCR Readable Mail according to the chart below Font Name PrecisionID Postnet Character Symbol and recommended point size to print at HI I 28 or 20 points LL 28 or 20 points M 28 or 20 points II 28 or 20 points NO POSTAGE NECESSARY IP MAILED IN THE UNITED STATES 36 points 36 points 48 points 48 points 48 points 48 points 48 points 48 points 48 points Copyright 2005 PrecisionID com
5. d formatted the data from the database and appended additional characters at the beginning and ending of the text The result should look something like this 123451234122 9 Switch back to design mode select the formula field and choose the PrecisionID Postnet font Set the point size to 10 points or to the size appropriate for your application You must select the appropriate font for the formula you are using 10 Size the formula field so 1t is large enough to contain the entire barcode You will need to adjust the width Be sure to leave some extra space to the right and left of the barcode on the report Generally you need about 10 times the space to the left and right of the barcode as the thickest bar in the Postnet barcode 11 The barcode should now be visible when you run your report ns Information for Specific Implementations Creating Check Digits in other Applications The easiest method of creating source code for a check digit in a custom application 1s to use our PrecisionlD Postnet Module bas module as a guide The module was written to be compatible with Visual Basic 6 and Microsoft Office VBA and may be viewed with a text editor This module is located in the Examples VB Module folder of the package Specifications Font names and point sizes Our fonts are designed to print with precision on both high and low resolution printers When printed at 10 points the fonts meet the USPS standard which 1s 22 to 24 bars per in
6. he results for the following tutorials are saved in the examples folder of the product zip file We encourage you to refer to the examples provided in this folder These examples assume your data does not contain the required check digit Microsoft Access To create a barcode in a Microsoft Access report U 2 U 10 Run the Setup program to install the fonts and Access Example file Before we can create barcodes in Access we must import the reguired module Choose Modules Import and select the Access Example mdb file which will be located in the Program Files Precision ID Postnet Font Package folder Open Choose the module to import from the other database this module should be named PrecisionID Postnet Module After it is properly imported it will appear as one of the modules in the database Open a report in design view and add a text box to your report The text box will be modified to contain a barcode Right click on the text box and choose properties Place the formula PrecisionID PNET Tablel Fieldl in the control source property of the text box where Tablel is the table and Fieldl is the field that contains the data you want to barcode Run the report You should see that the formula changed the data from the database and appended additional start stop characters at the beginning and ending of the text and calculated the check digit The result should look something like this 123451234122 Open a rep
7. icrosoft VBA module for Excel and Access and Visual Basic source code which may also be used as a guide for conversion to other languages All barcodes require start and stop characters Our Postnet fonts use either the asterisk or the open and closing parenthesis as the start and stop character We also include FIM and other Postnet related bar codes types in the Postnet font including Business Reply Mail and OCR Readable Mail In this package we also include the Planet font The Planet barcode is used for tracking USPS mail Our PrecisionID PNET function may also be used to calculate the check character for the Planet barcode because the check character calculation is the same as a Postnet barcode Installation Microsoft Windows Decompress the fonts in the supplied ZIP file with a decompression utility such as Winzip Our fonts are compatible with all 32 bit versions of Windows We recommend using the supplied Setup exe file to install the fonts automatically in Windows If you wish to manually install the fonts in Windows open Control Panel and choose Fonts then choose Install New Font and browse to the folder that contains the fonts with the TTF extension you extracted from the zip file Macintosh OS X Our fonts are compatible with all versions of Macintosh OS Version 10 1 and greater OSX Decompress the fonts in the supplied ZIP file with a decompression utility such as Stuffit Expander Drag the files with the TTF extension to the
8. list of modules Choose File Save then Close and return to Excel 5 In cell B8 enter the formula of PrecisionID PNET A8 which is required to format the data to the font 9 Text Data Barcode 10 19293 1234 PrecisionID PNET A10 6 You should notice that the formula changed the data from the spreadsheet and appended additional characters at the beginning and ending of the text 9 Text Data Barcode 40 19293 1234 1929312346 7 With cell B10 selected choose the PrecisionID Postnet font and choose 10 for the point size You must select the appropriate font for the formula you are using For example if you have a formula for a Postnet barcode you must use the Postnet Font 8 After selecting the bar code font you should see the barcode appear Size the width of the column so that there is some white space before and after the bars of the barcode B 10 19293 1234 PELLE EEE ELA ET LEE LEE EEE LE EMA LM 9 To create an entire column of barcodes choose Edit Copy with cell B10 selected 10 Highlight cells you wish to add barcodes to and choose Edit Paste The formula will automatically adjust for the other cells Microsoft Word Mail merge 1 Open the mail merge document 2 To create a barcode in a Word mail merge we must insert a merge field from a data source that already formatted the text to the barcode font In this example we use Excel as the data source The Excel spreadsheet data s
9. ort in design view select the text box and choose the PrecisionID Postnet font and choose 10 for the point size of the font You must select the appropriate font for the formula you are using For example if you have a formula for a Postnet barcode you must select the Postnet Font Size the text box so it is large enough to contain the entire barcode You will need to adjust both the height and width Be sure to leave some extra space to the right and left of the barcode on the report Generally you need about 10 times the space to the left and right of the barcode as the thickest bar in the Postnet barcode Save and run your report You should see the barcode appear in the text box The result should look something like this Microsoft Excel 1 2 3 In this example we will create a barcode in cell B10 using the data from cell A10 for the barcode Extract the PrecisionID Postnet Module bas file from the package and place it in the My Documents folder Before we can create barcodes in Excel we must import the required module and change the security setting so it will run In Excel choose Tools Macro Security and set the security level to Medium Choose Tools Macro Visual Basic Editor Data Window Help Security 2 visual Basic Editor Alt F11 Choose File Import File and select the PrecisionID Postnet Module bas file from the list of files After this module is imported it will be visible in the
10. ource must already be setup with barcodes just like the Excel Tutorial in this document 3 In Word Choose Tools Letters and Mailings Mail Merge and select the Excel spreadsheet for your data source Be sure to select the columns and range for the cells that contain the data formatted to the barcode font You may have to go through the Word mail merge tutorial for assistance if you are unsure of how to connect to a data source or perform a mail merge 4 When connected to the data source we insert the merge field of FormattedText into the document When we choose the View Merged Data option we see the text formatted to the barcode font from the data source appear The result should look something like this 123451234122 5 Choose the PrecisionID Postnet font for this merged field and choose 10 for the point size 6 The barcode should appear when you run the merge Crystal Reports This example was created in Crystal Reports version 8 Implementation in other versions of Crystal Reports is very similar if not identical The fonts and UFL are compatible with Crystal version 7 and above 1 Open your Crystal Report and switch to design mode In version 8 choose Insert Formula Field or in version 9 and above choose Report Formula Workshop 2 Right Click on Formula Fields and choose New Ej Formula Workshop X Close D X Z xl E Report Custom Functions Repository Custom Functions Formula Fielda
11. sesssesssoseso 5 Creating Check Digits in other Applications j ssov k zoak sako k oo ln 5 SPECMICALONG oo k ld rv p Td 6 Font names and point sizes pre o okn kk r r aus 6 FIM and other Postnet related bar codes types nina mentalement 6 Postnet Symbology Overview The USPS defines a few different methods of printing Postnet The 5 digit Postnet barcode consists of the start stop character 5 digit ZIP code data check digit and the start stop character The ZIP plus 4 Postnet bar code consists of the start stop character 9 digit ZIP code data check digit and the start stop character The most popular Postnet barcode in use today is the DPBC Postnet which consists of the start stop character 9 digit ZIP code data two DPBC numbers a check digit and the start stop character for a total of 62 bars The two DPBC numbers are usually the last two digits of the street address or PO Box number To obtain more information we recommend obtaining the USPS document titled Domestic Mail Manual from www usps gov Product Overview This Postnet Barcode Font Package contains 2 versions of TrueType and PostScript fonts each supplied in normal and light format which is about 15 lighter The package also contains complete documentation specifications and implementation examples In the event that your data source does not already contain the required check digit we provide PrecisionID Font Formatting Components TM which include a Crystal Reports UFL M
Download Pdf Manuals
Related Search
Related Contents
Norms on Radiological Safety G shdsl bis Bridge Modem SHDTU03b BUG PR。。F STANM。CK CO2 Fire-Suppression System - ncfft 全文 2361K - 鹿児島工業高等専門学校 User Manual BETRIEBSANLEITUNG Tauchmotorpumpe ESP und CSP K391 - カーメイト Copyright © All rights reserved.
Failed to retrieve file