1. Quick Start Guide for ADC SDI CC Without GYDA controller This is the default setting upon shipping 1 Set DIP switch 1 on towards backplane switches 2 and 3 according to the input mode you want see Table 2 on page 9 2 Insert ADC SDI CC into a slot in the sub rack 3 Attach Analogue input CVBS S Video RGB sync or YPbPr and SDI output to the backplane module see Figure 2 on page 7 4 Power on After some seconds the ADC SDI CC will be running and the input detected All LED s will be green and the SDI output active If this is not the case please see section 5 2 Front Panel Status Monitoring on page 12 With GYDA controller firmware gt 1 1 Insert ADC SDI CC into a slot in the sub rack Attach Analogue input CVBS S Video RGB sync or YPbPr and SDI output to the backplane module see Figure 2 on page 7 Power on After a few seconds the ADC SDI CC will be running and the card detected by GYDA Use GYDA to set up which analogue video format to use CVBS S Video RGB sync or YPbPr All LED s will now be green and the SDI output active The card settings are stored on the card which means that the card will remember its configuration despite any eventual power loss Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be chan
2. hrbom Position Quality Manager authorised signature Network Electronics ASA www network electronics com P O Box 1020 3204 Sandefjord Norway network network electronics com Tel 47 33 48 99 99 Fax 47 33 48 99 98 Enterprise No NO 976 584 201 MVA
3. xxxxCVBS Locked 50Hz Field I mark on Comb on Pedestal on Status of Status string Comment Input Select CVBS CVBS is selected Svideo Svideo is selected YpbPr YPbPr is selected RGB RGB is selected Analogue input Locked 50Hz Locked to 625 lines 50 Hz Locked 60Hz Locked to 525 lines 60 Hz Not locked 50Hz Not locked previously locked to 50Hz Not locked 60Hz Not locked previously locked to 60Hz Field 1 marking Field 1 marking on The Mark Field 1 feature is turned on Field 1 marking off The Mark Field l feature is turned off Chroma filter Comb on Comb filter selected Comb off Chroma trap filter is selected Pedestal Pedestal on Pedestal present is selected Pedestal off Pedestal not present is selected Table 6 The info command broken up in components The info command is composed by many minor lines fully specified in table 6 In general when a condition is normal it is not reported For instance pedestal is reported when locked to 50Hz even tough the setting has no effect on the video 6 4 Video modes commands The CVBS RGB Svideo and YPbPr commands sets the video input mode Remember that RGB mode needs separate sync on the CVBS Luma channel This sync may be a synchronous CVBS signal Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web htt
4. 2 Input Channel select 3 ipai Channel select Aevording to Table a 4 Mark Field 1 enable on off When on the Mark Field l feature enabled 5 Comb filter Trap filter When on the comb filter is selected When off the trap filter is selected 6 Pedestal on off If a setup level of 7 5 IRE is present on your analogue video set to on When black level is 0 IRE set to off This setting only applies to 525 lines video standard 7 Reserved 8 Factory Reset on off To reset the internal EEPROM 9 Reserved 10 Run mode on off For factory use only Table 1 Summary of the DIP switches Switch 7 9 and 10 are mainly for factory use while switches 1 2 3 4 5 and 6 will be used when no GYDA controller is available Switch 1 Manual mode Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice ADC SDI CC Rev 3 DATE 23 July 2008 Switch 1 is the manual mode switch If on the ADC SDI CC may be operated with the switches If off the ADC SDI CC is to be used with a GYDA controller Factory setting is switch 1 in on position With switch 1 off While in automatic mode switches 2 3 4 5 6 and 8 do not have any effect With switch 1 on In manual mode the functionality of switches 2 3 4 5 6 and 8 is as follows
5. ADC SDI CC card will enter programming mode This causes no harm but the card will not work in this mode Factory setting is switch 10 in on position 4 2 Reset The push button just behind the front LEDs is a reset switch see Figure 3 It has the same effect as a power off power on cycle Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 10 ADC SDI CC Rev 3 DATE 23 July 2008 5 Module status The status of the module can be monitored in two ways 1 GYDA System Controller optional 2 LED s at the front of the sub rack The LED s are mounted on the module itself whereas the GYDA System Controller is a separate module which gives detailed information on the card status The functions of the LED s are described on the next page The GYDA controller is described in a separate user manual This manual is available on our web site http www network electronics com 5 1 GPI ALARM Module Status Outputs These outputs can be used for wiring up alarms for third party control systems The GPI outputs are open collector outputs sinking to ground when an alarm is triggered The GPI connector is shown in Figure 4 Electrical Maximums for GPI outputs Max current 100mA Max voltage 30V ADC SDI CC
6. Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labelled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circuit boards may contain battery backed memory devices Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 19 EC Declaration of Conformity network MANUFACTURER Network Electronics AS P B 1020 N 3204 SANDEFJORD Norway AUTHORISED REPRESENTATIVE Established within the EEA Not applicable MODEL NUMBER S ADC SDI CC DESCRIPTION Component and Composite Analogue Video Converter DIRECTIVES this equipment complies with LVD 73 23 EEC EMC 2004 108 EEC HARMONISED STANDARDS applied in order to EN 55103 1 1996 verify compliance with Directive s EN 55103 2 1996 TEST REPORTS ISSUED BY Notified Competent Body Report no Nemko E07379 00 TECHNICAL CONSTRUCTION FILE NO Not applicable YEAR WHICH THE CE MARK WAS AFFIXED 2008 TEST AUTHORIZED SIGNATORY MANUFACTURER AUTHORISED REPRESENTATIVE Established within EEA Date orissue 2008 07 14 Place of Issue a T 4 WG N Not applicable Sandefjord Norway CRE emaa 4 att N p20 got g16 O N AG Name Thomas
7. No input detected Input signal is detected Input signal is detected Video not yet locked or inputand properly locked comes from a VCR SDI Output INo SDI output Correct SDI output Table 4 Front panel LED indicator overview Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 12 ADC SDI CC Rev 3 DATE 23 July 2008 6 Interface with GYDA and RS 422 command set All commands follow the flashlink protocol and can be used for direct control access to the module The control system can either be a GYDA or a third party control system with integrated flashlink protocol The module can also be manually controlled with a VT100 compatible terminal program The protocol can be found on our web page http www network electronics com 6 1 ADC SDI CC Command table Command Response Comment Yes The Hello command info Yes Gives back the card state CVBS OK Set video format to CVBS Svideo OK Set video format to S Video RGB OK Set video format to component RGB sync YPbPR OK Set video format to component YPbPr MarkF1 on OK Turn on the Mark Field 1 feature MarkF1 off OK Turn off the Mark Field 1 feature Comb on OK Set chroma luma separation
8. The hazardous material content is limited to lead Pb in some solders This is extremely stable in normal use and the EFUP is taken as 50 years by comparison with the EFUP given for Digital Exchange Switching Platform in equipment in Appendix A of General Rule of Environment Friendly Use Period of Electronic Information Products This is indicated by the product marking Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 18 ADC SDI CC Rev 3 DATE 23 July 2008 It is assumed that while the product is in normal use any batteries associated with real time clocks or battery backed RAM will be replaced at the regular intervals The EFUP relates only to the environmental impact of the product in normal use it does not imply that the product will continue to be supported for 50 years Recycling information Network Electronics provides assistance to customers and recyclers through our web site http Awww network electronics com Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the product to Network Electronics or its agents for recycling the following general information may be of assistance
9. and component video e 10 bit component 8 8 8 oversampling with digital 4 2 2 decimation and down conversion e VBI data transparent e 3 SDI outputs CVBS Luma Red Pr mee Green Y decoder Serializer SDI Out Scrambler SDI Out Blue Pb Chroma SDI driver SDI Out GPI FPGA conf LED Microcontroller RS422 memory Switches with EEPROM Figure I Simplified block diagram of the ADC SDI CC card Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice ADC SDI CC Rev 3 DATE 23 July 2008 2 Specifications Digital Serial Output Signal type Connector Impedance Return loss Jitter Peak to peak signal level Composite and Y C Input Signal type Connector Impedance Signal level Return loss Component and RGB Input Signal rate Signal type Connector Impedance Signal level Return loss Processing Performance Signal path Sampling Luma Chrome separation Video bandwidth Hue Accuracy Colour Saturation Accuracy Luminance Nonlinearity SNR unified weighted Diff gain Diff phase Video processing delay Power SMPTE 259M ITU R BT 601 BNC 75 ohm gt 15dB 270MHz lt 0 2UI 800mV 80mV Composite video PAL 625 50Hz or NTSC 525 60Hz Y C S vid
10. filter to 5 line comb filter Comb off OK Set chroma luma separation filter to chroma trap filter Pedestal on OK Pedestal is present Pedestal off OK Pedestal is not present Calibrate OK Calibrates RGB gain Must be in RGB and input must be 75 colour bar eget OxHH Yes Get a value from a numbered eeprom register eset 0xHH 0xHH OK Set a value to a numbered eeprom register et 0xHH Yes Get a value from a numbered register ket 0xHH OxHH ORK Set a value to a numbered register Table 5 All commands available to the user 6 2 The command According to the flashlink no card can use the RS422 bus before it has been activated with the hello command The response from ADC SDI CC will be xxxxADC SDI CC PIC sw rev X X_X FPGA sw rev X Protocol ver XX Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 13 ADC SDI CC Rev 3 DATE 23 July 2008 Here xxxx denotes the source and destination rack and slot coordinates while X represents a version number As of primo July 2004 these revisions would be xxxxADC SDI CC PIC sw rev 1 0 2 FPGA sw rev 6 Protocol ver 1 0 6 3 The info command This command report the entire state of the card An example
11. 11363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 Environmentally friendly use period The manual must include a statement of the environmentally friendly use period This is defined as the period of normal use before any hazardous material is released to the environment The guidance on how the EFUP is to be calculated is not finalised at the time of writing See http www aeanet org GovernmentA ffairs qfLeOQpAaZXaMxqGjSFbEidSdPNtpT pdf for an unofficial translation of the draft guidance For our own products Network Electronics has chosen to use the 50 year figure recommended in this draft regulation Network Electronics suggests the following statement on An Environmentally Friendly Use Period EFUP setting out normal use EFUP is the time the product can be used in normal service life without leaking the hazardous materials We expect the normal use environment to be in an equipment room at controlled temperature range 0 C 40 C with moderate humidity lt 90 non condensing and clean air not subject to vibration or shock Further a statement on any hazardous material content for instance for a product that uses some tin lead solders Where a product contains potentially hazardous materials this is indicated on the product by the appropriate symbol containing the EFUP
12. E esses ca onadscanaiads danbesnncuomeaecumberenutoneateesenes 6 3 Connector MOE UN Gye cssedcsbbesdebeuieadeds eecacceshecastessidetocsiucet Utznsoasuslecectbsuid vonsavicseasnudcestsbedscnsancetedhpadceptabeccs 7 3 1 Correspondence of connectors and SIOTHAS ictoricasecnican ti xeuiedcateben Citak cea sainiiaa Wein bh ase cnbeaala nana oases 7 3 2 Mounting the connector module cay oto s Se see a tioh sata ryae Seas seh oe tae aca oie oie hat maa 7 4 Configuration and Setup ic ccsceccrccccccriasscssskcossssecensdscncdssndiuddepusseleoncdveseosassacdosbssudapstspabesnsbonsbonsteeesisectacseutus 8 41 Setting the DIP SW TIONS maneri r n E A acetal A E A E A a 8 BOAT AA ON E TEE AEE E E A EAE ala 10 S Mod le stats acecsscesoussvecthaacencgeesustecwsbuuczsnacoubscbcananesbsuudeebeantsngndicnnessobseuacesesvbuaeseuarasesouuatsseswhsouseuusssessuusess 11 5 1 GPI ALARM Module Status Outputs fe fo oo Ca conta te ooean cs das sc pads Soipadewn soba ead Sar OS lI 5 2 Front Panel Status Monitoring ossnsneensnneneeneeeneseeseesensseesreseosreestesetsstesresstesresresstesreeresseosrtenet t 12 6 Interface with GYDA and RS 422 command set seeseessessoesoesoesooesoesoesooesossseseossoessessossoossessossoossessose 13 CT ADCSDECC Command table semerre an E E made octane E E E 13 6 2 Then commana a a E E E R E A ES AEH R E E A 13 6 3 Theine commande irena LA EA AeA EAE Dee EA EE EA aston ON EA EAAS 14 6 4 Video modes commands seis a a E RE aS 14 6 5 Ma
13. Switches 2 and 3 These two switches determine the input selection See Table 2 Factory setting is switch 2 and switch 3 off Sw 3 Sw 2 Input Channel Select 0 0 CVBS 0 1 S Video 1 0 YPbPr 1 1 RGBS Table 2 Manual selection of video mode Switch 4 Switch 4 turns on off the Mark Field l feature With switch 4 off the Mark Field l feature is disabled with switch 4 on the Mark Field 1 feature is enabled and the card inserts a marker on line x of each field 1 This features gives improved encoding quality when used with an encoder like the DAC SDI which can use this feature Factory setting is switch 4 in on position Switch 5 Switch 5 selects which filter to use when separating Luma from Chroma in CVBS With switch 5 on the 5 line comb filter is selected with switch 5 off the chroma trap filter is selected Factory setting is switch 5 in on position Switch 6 Switch 6 selects whether pedestal is present on the analogue video With switch 6 on the black level will be set to 7 5 IRE With switch 6 off the black level will be 0 IRE This switch only affects 525 lines video Typically a black level of 7 5 IRE is used in the USA and 0 IRE in Japan Factory setting is switch 6 in on position Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specificati
14. X ADC SDI CC Multi standard NTSC PAL YPbPr RGB Decoder Converter Component and Composite Analogue Video Converter Rev 3 l D fone ie e a Oo D Q ao ten e a ya n e ADC SDI CC Rev 3 DATE 23 July 2008 Revision history The latest version is always available in pdf format on our web site http www network electronics com Current revision of this document is the uppermost in the table below Revision Replaces Date Change Description 3 2 2008 07 14 Added Declaration of Conformity 2 1 2007 10 23 New front page and removed old logo 1 0 2007 10 09 Added Materials Declaration and EFUP 0 B 03 03 05 oye update and changed ConQuer to B A 02 09 04 First preliminary release 12 08 04 Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice ADC SDI CC Rev 3 DATE 23 July 2008 Index Quick Start Guide for ADC SDI CC ccsssssssssssessssssssonsescesessssssnsensscssesssssensonsesssesessssssnsecssssssosessesees 4 1 General scccsccssustaiectees vccscarscassascaecencstedsssbtesiaeissiedens bhcacdesieeusau tated ues sebecsc sceusdeuasyouuasttess dancctadesestucencttedtustustse 5 Zs DPC CHIC AUT COS EREE EE A EE vase sabes E
15. ect to be changed without notice 16 ADC SDI CC Rev 3 DATE 23 July 2008 Product Warranty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Network Electronics AS These conditions are available on the company web site of Network Electronics AS www network electronics com Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 17 ADC SDI CC Rev 3 DATE 23 July 2008 Materials declaration and recycling information Materials declaration For product sold into China after 1st March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the required information Toxic or hazardous substances and elements ARER i R t KIE RRE SR FM Part Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium biphenyls diphenyl ethers Cr VI PBB PBDE ADC SDI CC X O O O O O O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T
16. eo BNC 75 ohm Vp p gt 40dB 625 50Hz or 525 60Hz RGB without setup with separate sync SMPTE EBU Y Cr Cb BNC 75 ohm Y 1Vp p Cb Cr R G B 0 7Vp p gt 40dB 10 bits 27MHz 2 x oversampling selectable 5 line adaptive comb filter or chroma trap filter 6MHz 0 5 typical 0 8 typical 0 6 typical 66dB typical lt 1 0 lt 1 0 3 video lines 5V DC 2 75W 15V DC 0 5W Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice ADC SDI CC Rev 3 DATE 23 July 2008 3 Connector module The ADC SDI CC has a dedicated connector module ADC SDI CC C1 This module is mounted at the rear of the sub rack The module is shown in Figure 2 R Pr CUBS Y slectronics as n Norway Figure 2 ADC SDI CC C1 connector module 3 1 Correspondence of connectors and signals The ADC SDI CC C1 connector module has 7 BNC s CVBS Y Analogue input CVBS SYNC for RGB or S Video Luma R Pr Analogue input Red or component Pr G Y Analogue input Green or component Y B Pb C Analogue input Blue component Pb or S Video Chroma SDI OUT Digital SDI output SDI OUT Digital SDI output SDI OUT Digital SDI output SDI SDI and SDIB are equivale
17. ged without notice ADC SDI CC Rev 3 DATE 23 July 2008 1 General The flashlink ADC SDI CC is a high quality digital video decoder that digitises and decodes all popular baseband video formats into SDI 4 2 2 digital component video The ADC SDI CC supports the analogue to digital conversion of component RGB and YPbPr signals as well as the decoding of NTSC and PAL composite and S video into component digital video This decoder features four 10 bit A D converters running with 2 x oversampling 27MHz which are then digitally filtered and decimated to the 1 x pixel rate giving a higher signal to noise ratio for each input channel When used with the GYDA control system gain adjustments may be made to each analogue input Composite video decoding utilises a 5 line adaptive comb filter for both the luma and chroma signal paths to reduce cross luma and cross chroma artefacts A alternative chroma trap filter is also available On composite and S video inputs the user can control video characteristics such as contrast brightness saturation and hue via the GYDA control interface The GYDA system controller is used with all flashlink and flashlink modules providing a common control and monitoring platform ADC SDI CC features e Multi standard NTSC PAL YPbPr RGB Decoder Converter e 10 bit 4 2 2 SDI video quality e 5 line adaptive comb filter for NTSC PAL decoding e EDH generation and insertion e 2x oversampling of both composite
18. module GPI pinning Signal Name Pin Mode Status General error status for the module Pin 1 Open Collector va Input No video input detected Pin 2 Open Collector VCXO Module not gen locked to video input Pin3 Open Collector free flue SDI Output No SDI output present Pin 4 Open Collector Ground 0 volt pin Pin8 OV era Figure 4 GPI Outlet Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 11 ADC SDI CC Rev 3 DATE 23 July 2008 5 2 Front Panel Status Monitoring The status of the module can be easily monitored visually by the LED s at the front of the module The LED s are visible through the front panel as shown in Figure 5 below Card State Input O VCXO SDI Output Text not printed on the front panel Figure 5 Front panel indicator for ADC SDI CC The ADC SDI CC has 4 LED s each showing status information The position of the different LED s is shown in Figure 5 Diode state Red LED Yellow LED Green LED No light Card State Module is faulty Start up sequence is running Module is OK Module has no Module power is OK power or memory fault Input No video input Video input detected detected VCXO
19. nt SDI outputs Note The analogue inputs are internally terminated with 75Q on the ADC SDI CC card 3 2 Mounting the connector module The details of how the connector module is mounted is found in the user manual for the sub rack frame FR 2RU 10 2 This manual is also available from our web site http www network electronics com Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice ADC SDI CC Rev 3 DATE 23 July 2008 4 Configuration and Setup Programming header AOU FPGA configuration H 17 EEPROM Video Bior __ o A sFate uc f 3 s op s VCXO INPUT sw rn 8 m 8 pa 2 pre SDI vexo E iii out en Li OUTP Figure 3 ADC SDI CC simplified silkscreen 4 1 Setting the DIP switches The ADC SDI CC card has a Dual Inline switch DIP switch that has 10 individual On Off switches The purpose of these switches is to provide an easy interface to some of the most used features of the ADC SDI CC card without the need of a GYDA controller The switches are numbered from 1 towards the top of the card see Figure 3 A switch is off when the tap is placed in direction of the front handle Switch Function Comment 1 Manual mode on off When on enables switches 2 3 4 5 6 and 8
20. ons are subject to be changed without notice ADC SDI CC Rev 3 DATE 23 July 2008 Switches 7 and 9 Reserved These switches are reserved and should always be in the off position Factory setting are switch 7 and 9 in off position Switch 8 Reset to factory default ADC SDI CC contains an EEPROM which stores the configuration of the card Switch 8 can be used to reset the EEPROM to the factory default Follow the procedure described below Action Comment 1 Power down 2 Turn switch 8 on Switch must also be turned on for this to have effect 3 Power up ADC SDI CC enters a special state where the EEPROM is restored to factory default values This is flagged by the Card State LED which starts to blink yellow 4 Power down 5 Turn switch 8 off If you want the DIP switches to be placed in the factory default position this is the time to do so Switch 10 should as always be turned to the on position Switch 1 may be turned on or off 6 Power up The card EEPROM is now reset to factory settings Table 3 Method to restore the ADC SDI CC card to factory settings Remember to let some seconds pass by each time you power down to allow capacitors to be fully discharged Switch 10 Run mode Switch 10 is purely used for service upgrade of the ADC SDI CC card It should always be in the on position If switch 10 is in the off position the Card State LED will light up red and the
21. p www network electronics com Technical specifications are subject to be changed without notice 14 ADC SDI CC Rev 3 DATE 23 July 2008 6 5 Mark Field 1 Pedestal and Comb commands Commands to turn on off the Mark Field 1I feature Pedestal and the Comb filter commands are straightforward text see Table 5 6 6 get set eget and eset These commands are for internal factory use The end user should avoid these commands Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 15 ADC SDI CC Rev 3 DATE 23 July 2008 General environmental requirements for Network flashlink equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature range 0 C to 40 C Operating relative humidity range up to 90 non condensing The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 50 C Relative humidity range up to 95 non condensing Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subj
22. rk Field 1 Pedestal and Comb commands cscccsceecceesseeeseteeeceeeeees ceca eecaeceneeeeseeeseeeeeeneeenees 15 6 6 pel Set eget and Eseli i e A EA E E E iat E a ea E a a ac tatas 15 General environmental requirements for Network flashlink equipment seesseossooesoossssssssesssecssosse 16 Prod ct Warranty ssisissisisiosseso ces cudencin esa seoscedanssiecds seven E eei ESKE OSES Ser ONES Eo CE oD SESS OSs Koo ESSES 17 Materials declaration and recycling information e ssoessoesssesssesssoccssoossooessossssesssesssoossoosssosssssessesssosse 18 Materials declaration is cos ccutecessssesscersteacescantesebedeteustessssucpiebcadessesstssacsesonssebsactanenstsvacsebbascouneaepbietcausdeontnauties 18 Environmentally friendly use period oessooessoesssesssessseossoosssosssoesssesssoessoosssoosssossssessseessoossoossssesssesssose 18 ROC y Cling TMTOLIM ATION ss sssi concesuceascarcassccuscaapacscesastscanusnasvucessussatassieguadoseseecdonusbaouepesoatassuvbiacansiasshaesentcoieds 19 EC Declaration OF Conformity 4 scseccocsasisccasasecssesedsssccsoswssedessesssceoswes sebotssencdosucs ssvsusd sdsebseoscdcsecsacseadsceccoasssda 20 Network Electronics AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice ADC SDI CC Rev 3 DATE 23 July 2008