CO2 Indicator/Controller Model #: TON
Contents
1. Fig 2 wall plate H H HHHH Ee H HH D i 28 00 5 wg 5 00 ma 5 H 50 J 8 00 L f 45 00 D j q S Fi If HHHHHHHHHHHH Nem i 60 00 Common ON Line P Voltage 24VAC Transformer b CHO CHHHHHH HHH HHH CO2 level Relay turns on turns off J4 disconnect J5 disconnect 800ppm CO2 gt 900ppm the relay on CO2 lt 700ppm the relay off J4 connect J5 disconnect 1000ppm CO2 gt 1100ppm the relay on CO2 lt 900ppm the relay off J4 disconnect J5 connect 1200ppm default CO2 gt 1300ppm the relay on CO2 lt 1100ppm the relay off J4 connect J5 connect 1400ppm CO2 gt 1500ppm the relay on CO2 lt 1300ppm the relay off Important Instructions Don t shake or hit the CO2 unit too much in shipment or in mounting to protect the internal infrared CO2 1 sensor from any damage and excursion of infrared receiver When open the cover of the CO2 unit you ll see one PCB board mounted over another bigger PCB board This upper small PCB board is loaded with CO2 sensor Don t uninstall the CO2 module without instruction from our engineers in order not to cause any damage to the CO2 sensor Please note the pins on the CO2 module which connect with the bigger PCB board have direction Wrong connection will cause the CO2 module and processor damaged
2. TRCO2Meter com CO2 Measurement Specialists 131 Business Center Drive Ormond Beach FL 321 74 386 872 765 Sales 386 256 4910 Support www CO2Meter com Sales CO2Meter com
3. CO2 Indicator Controller Model TON 0007 User Manual Specifications Power supply 24VAC VDC Consumption 1 5 W Max 0 8 W avg Infrared Sensor with lifetime of 15 years ABC Logic Self Calibration default effective CO2 measuring range O 2 000ppm CO2 sensor Accuracy 25 77 2000ppm 40ppm 3 of reading or 75ppm whichever is greater Response time lt 2 minutes for 90 step change Warm up time for each turning on 2 hours first time 2 min operation 1st green light on as CO2 measurement lt 600ppm 15t and 2 green lights on as CO2 measurement gt 600ppm and lt 800ppm 6 LED lights 1st yellow light on as CO2 measurement gt 800ppm and lt 1 200ppm 15t and 2 yellow lights on as CO2 measurement gt 1 200ppm and lt 1 400ppm 1 red light on as CO2 measurement gt 1 400ppm and lt 1 600ppm 15t and 2 red lights on as CO2 measurement gt 1 600ppm On Off output for control CO2 level lt 240VAC 30VDC 3A switching current resistance load Operation conditions 0 50 C 32 122 F O 95 RH non condensing Storage conditions 0 50 C 32 122 F Dimensions 100mm X 80mm x 28mm H X W X D 65mm X 65mm 2 X 4 wire box Mounting and Wire Connection Notice the supply power voltage of the detector 24VAC Do not install the detector on voltages higher than marked on the detector Firstly prepare a flat head screwdriver and put it inside of the hole on the top of the detector housing following step 1 and the
4. n open the cover from step 2 to step 4 in next page fig 1 Mount the wall plate first dimensions see next page fig 2 coveeee by seras aeres Connect wires to terminal strips see fig 3 GOAN eee Follow step 5 to step7 in fig 4 to close the cover Fig 1 open the cover JUUUUU Hi l AN Fig 4 close the cover IS pr i a if i E 2 SI 5 SRY 6 val it ek NA f AY V Y Y FH A J Fig 3 wiring diagram Connection Terminal _ Power ground 24VAC VDC Ventilator Relay output Select CO2 level to Control the Relay lt 240VAC 30VDC 3A switching current resistance load The CO2 level for control the relay turning on has been set to 1200ppm If you need to change the CO2 level open the cover after switch off you may see two jumpers J4 and J5 on the top of the circuit board and under the CO2 module Take off the CO2 module you can select the CO2 level to control the relay on off by jumpers as below table
Download Pdf Manuals
Related Search
Related Contents
Bryant 454 Air Conditioner User Manual Français - Clarion SERIAL/PARALLEL I/O PCI EXPRESS ADD CMG Series Gas Flow Monitor USA Model User`s Manual MX Product Manual 取扱説明書 Tannoy Mercury Vi ASP TCNL 13-12 22-24 manual español 浴室換気暖房乾燥機 Copyright © All rights reserved.
Failed to retrieve file