Home
USER MANUAL OxYGEN SUPPLY MANIFOLD
Contents
1. AND LIMITATION OF LIABILITY Precision Medical Inc warrants that the Oxygen Supply Manifold the Product will be free of defects in workmanship and or material for the following period Oxygen Supply Manifold Unit Two 2 years from shipment 20 ft Oxygen Supply Hose One 1 year from shipment Excludes Oxygen Therapy Masks amp Carry Case Should any failure to conform to this warranty appear within the applicable period Precision Medical Inc shall upon written notification thereof and substantiation that the goods have been stored installed maintained and operated in accordance with Precision Medical Inc s instructions and standard industry practice and that no modifications substitutions or alterations have been made to the goods correct such defect by suitable repair or replacement at its own expense ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES The representatives of Precision Medical Inc or any retailers are not authorized to make oral warranties about the merchandise described in this contract and any such statements shall not be relied upon and are not part of the contract for sale Thus this writing is a final complete and exclusive statement of the terms of that contract THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY WHETHER EXPRESS OR IMPLIED Precision Medical Inc shall not under any circumstances be
2. USER MANUAL OXYGEN SUPPLY MANIFOLD Model No PM106 Series SAVE THESE INSTRUCTIONS ACAUTION Federal USA law restricts this device to sale by or on the order of a physician PRECISION MEDICAL 300 Held Drive Tel 001 610 262 6090 Northampton PA 18067 USA Fax 001 610 262 6080 www precisionmedical com CONTENTS RECEIVING INSPEGCTION vccsccccccsctesccnsteeschesitscesceassnesaseennetences 2 INTENDED USE vis cicccis santa aiii e i ieahnied omnes 2 READ ALL INSTRUCTIONS BEFORE USING rrrrvrvrvrvvrrvvrrrernrn 2 EXPLANATION OF ABBREVIATIONS im mvvvrrvvvrervrervrerverrverrvernrnr 2 SAFETY INFORMATION WARNINGS AND CAUTIONS 3 SPEGCIFIGA TIONS suse 5 COMPONENT DESCRIPTION mrnvvrrvvevvvrvrvrverrverrverrreeveveveerveenne 6 OPERATING INSTRUCTIONS kurrvnnvornvnnsvennennnennnennvenevenneenneenne 7 DISSASEMBLE sne 7 MAINTENANCE CLEANING rarvvrvrrrvrvrvvrvrvrrrervrervrervrerversverrreenrer 8 RETURNS unne de gas nr dende 8 DISPOSAL INSTRUCTIONS verste 8 TROUBLESHOOTING darain aea e E aE i 9 REPLACEMENT PARTS nngndesmrssnnmunseensamnianet 9 LIMITED WARRANTY senenmaersnasneraatevrnnsiesraavsanaersansnnetvasserseev ve 10 oma RECEIVING INSPECTION Remove the Precision Medical Oxygen Supply Manifold from the packaging and inspect for damage If there is any damage DO NOT USE and contact your Provider INTENDED USE Precision Medical Inc Oxygen Supply Manifold provides oxygen therapy for up to six pe
3. cm Width 12 388 in 31 45 cm Height 4 25 in 10 80 cm Oxygen Hose Length fully extended 20ft 6 1 m Weight Oxygen Manifold Weight includes Oxygen Supply Manifold oxygen hose 6 oxygen therapy masks amp Carry Case 6 75 Ibs 3 07 kg Shipping Weight 7 40 Ibs 3 36 kg Operating Conditions Temperature O F to 122 F 18 C to 50 C Altitude Sea Level to 5 280 ft 0 to 1 690 m Storage Conditions Temperature 40 F to 140 F 40 C to 60 C Maximum Humidity 95 Noncondensing Supply Pressure 50 psi Flow Settings 0 15 lpm variable Specifications are subject to change without prior notice OXYGEN SUPPLY MANIFOLD 5 COMPONENT DESCRIPTION ACAUTION Missing or illegible labels must be replaced contact Precision Medical Inc Oxygen male DISS with check valve Control Knob 6 each Pressure Indicator JM Arrow Oxygen male DISS with check valve 6 each Oxygen Supply Manifold Kit m OXYGEN SUPPLY 6 MANIFOLD OPERATING INSTRUCTIONS AWARNING Read this User Manual before installing or operating the Oxygen Supply Manifold e Monitor patient and the oxygen flow on a frequent basis e DO NOT direct flow of oxygen at any person or flammable material when cracking the oxygen cylinder Inspect Oxygen Supply Manifold to ensure it is free of oils grease or other contaminations CAUTION Inspect the Oxygen Supply Manifold f
4. liable for special incidental or consequential damages including but not limited to lost profits lost sales or injury to person or property Correction of non conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical Inc whether based on contract negligence strict tort or otherwise Precision Medical Inc reserves the right to discontinue manufacture of any product or change product materials designs or specifications without notice Precision Medical Inc reserves the right to correct clerical or typographical errors without penalty my DO KPD mm OXYGEN SUPPLY 10 MANIFOLD PRECISION MEDICAL Precision Medical Inc 300 Held Drive Northampton PA 18067 USA Toll Free Tel 800 272 7285 Toll Free Fax 800 353 1240 Tel 610 262 6090 Fax 610 262 6080 www precisionmedical com ISO 13485 Certified 505135 Rev1 E 08 30 07 Printed in USA
5. ople simultaneously from an oxygen source in addition to having the ability to use a resuscitator READ ALL INSTRUCTIONS BEFORE USING This manual instructs a Professional to install and operate the Oxygen Supply Manifold This is provided for your safety and to prevent damage to the Manifold If you do not understand this manual DO NOT USE the Manifold and contact your Provider ADANGER This product is not intended as a life sustaining or life supporting device EXPLANATION OF ABBREVIATIONS DISS Diameter Indexed Safety System psi Pounds Per Square Inch lpm Liters Per Minute OXYGEN SUPPLY 2 MANIFOLD SAFETY INFORMATION WARNINGS AND CAUTIONS DANGER AWARNING ACAUTION CAUTION A Re Q Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage CONSULT ACCOMPANYING DOCUMENTS Symbol for use no oil Symbol for SINGLE USE AWARNING Only personnel instructed and trained in its use should operate the Oxygen Supply Manifold Use this Oxygen Supply Manifold fo
6. or visual damage before use DO NOT USE if damaged N RO Attach one end of the Oxygen Supply Hose to the Manifold and the other end Oxygen Supply Hose to a 50 psi oxygen source Attach up to six 6 oxygen supply masks to the Oxygen Supply Manifold tubing nipple mask connections Place oxygen supply mask on patient s Turn the control knob until prescribed setting is aligned with the Setting Indicating Arrow 4 on the Oxygen Supply Manifold DISASSEMBLE 1 2 3 OXYGEN SUPPLY Turn OFF the 50 psi oxygen source Remove the hoses from the oxygen source and the Manifold Place Component back into Carrying Case MANIFOLD 7 MAINTENANCE CLEANING ACAUTION e DO NOT use liquid leak detector to test for leaks All connections shall be tight and leak free CAUTION DO NOT steam autoclave e DO NOT immerse Oxygen Supply Manifold into any liquid DO NOT use any strong solvent or abrasive cleaners 1 Disconnect all connections before cleaning 2 Clean exterior surfaces of the Oxygen Supply Manifold and Oxygen Supply Hose with a cloth dampened with mild detergent and water 3 Wipe dry with a clean cloth 4 Store the Oxygen Supply Manifold in the carrying case in a clean area free from grease oil and other sources of contamination RETURNS Returned products require a Returned Goods Authorization RGA number contact Precision Medical Inc All
7. r its intended use as described in this manual Medical Oxygen should meet the requirements of USP Always follow ANSI and CGA standards for Medical Gas Products and Flowmeters and Oxygen Handling The Oxygen Supply Manifold should be serviced by a qualified service technician OXYGEN SUPPLY MANIFOLD AWARNING DO NOT use the Oxygen Supply Manifold near any type of flame or flammable explosive substances DO NOT use the Oxygen Supply Manifold with an oxygen supply hose that appears worn cracked or has damage DO NOT smoke in an area where oxygen is being administered DO NOT use if dirt or contaminants are present on or around the Oxygen Supply Manifold or connecting devices DO NOT use oils grease organic lubricants or any combustible materials on or near the Oxygen Supply Manifold ACAUTION The Oxygen Supply Manifold contains magnetic ferrous material that may affect the results of an MRI Store the Oxygen Supply Manifold in a clean area free of grease oil and other sources of contamination The Oxygen Supply Mask is for single patient use only CAUTION DO NOT steam autoclave DO NOT gas sterilize with ETO DO NOT clean with aromatic hydrocarbons OXYGEN SUPPLY 4 MANIFOLD SPECIFICATIONS Dimensions Oxygen Supply Manifold ONLY Length 7 78 in 19 76 cm Width 4 85 in 12 32 cm Height 2 22 in 5 64 cm Carrying case Length 16 75 in 42 55
8. returns must be packaged in sealed containers to prevent damage Precision Medical Inc will not be responsible for goods damaged in transit Refer to Precision Medical Inc Return Policy available on the Internet www precisionmedical com DISPOSAL INSTRUCTIONS This device and its packaging contain no hazardous materials No special precautions need to be taken when disposing the device and or its packaging Please Recycle Wk OXYGEN SUPPLY MANIFOLD TROUBLESHOOTING If the Oxygen Supply Manifold fails to function consult the Troubleshooting Guide below If problem cannot be solved by using Troubleshooting Guide consult your Equipment Provider Problem Probable Cause Remedy No Flow 1 Oxygen source is not 1 Turn ON the oxygen turned ON source 2 Control knob is in the 2 Turn the valve ON OFF position 3 Cylinder empty or 3 Replace cylinder source depleted 4 Hose is loose or not 4 Check connection of connected hose and reconnect hose REPLACEMENT PARTS Description Part User Manual 505135 Oxygen Therapy Mask 505137 Oxygen Therapy Mask Case 50 505137 50 Oxygen Supply Hose Green 20 ft 505136 Oxygen Supply Hose White 20 ft 505490 Bumper Pack 6 502396 6 Carry Case 505258 Velcro Strap for Carry Case 505261 Oxygen Supply Manifold ONLY 505568 CANADIAN Oxygen Supply Manifold PM106C OXYGEN SUPPLY MANIFOLD 9
Download Pdf Manuals
Related Search
Related Contents
ekf 364 d ud ekf 411 d QSC ISA 450 User's Manual LANDE LN-DGR-AYD-1UMG-XX rack accessory Ristrutturazione dei piani terra, primo, secondo e terzo, con la Nec - VideoCorp GPS MAP 178C クイック・リファレンス・ガイド LB90 - Came Europe Combi-Desinfectant User Manual Copyright © All rights reserved.
Failed to retrieve file