Home
User Manual (English)
Contents
1. LEAKATOR _ BACHARAC Combustible Gas Leak Detector f Instruction 19 9336 Rev 1 November 2010 12 Inch Audible Alarm Flexible Probe e Instrument Ready Slow beep The beep rate is about once per second with no gas detected e Combustible Gas Indication Beeps at a rate that increases along with the gas concentration e Sensitivity Produces an increasing frequency tone when sensitivity changes from low to high and produces a decreasing frequency tone when sensitivity changes from high to low e Dead Batteries High frequency tone fol lowed by the instrument turning itself OFF e Sensor Error Rapidly changing high and low frequency tones Visual Alarm LED e Power ON Rapidly flashes green during warm up approximately 60 seconds e Power OFF Glows red just before power OFF e Instrument Ready Slowly flashes green The flash rate is about once per second with no gas F detected q e Combustible Gas Indication Flashes green at gt a rate that increases with the gas concentration e Sensitivity Change Color changes from red to green e Low Battery Flashes orange instead of green when checking for gas leaks Typically 1 hour of operation left after LED changes to orange Change batteries as soon as convenient e Dead Batteries Glows red followed by the instrument turning itself OFF Combustibles Sensor e Sensor Error Flashes alternating green and red amp Sensor Cover Batte
2. 4 Canada Phone 905 470 8985 Fax 905 470 8963 Email bachcan idirect com Warranty Bacharach Inc warrants to Buyer that at the time of delivery this Product will be free from defects in material and manufacture and will conform substantially to Bacharach Inc s applicable specifications Bacharach s liability and Buyer s remedy under this warranty are limited to the repair or replacement at Bacharach s option of this Product or parts thereof returned to Seller at the factory of manufacture and shown to Bacharach Inc s reasonable satisfaction to have been defective provided that written notice of the defect shall have been given by Buyer to Bacharach Inc within two 2 years after the date of delivery of this Product by Bacharach Inc For full details concerning this warranty contact Bacharach Inc 621 Hunt Valley Circle New Kensington PA 15068 7074 Ph 724 334 5000 Fax 724 334 5001 Toll Free 800 736 4666 Webside www MyBacharach com E mail help MyBacharach com P Registered Trademark Bacharach Inc Printed in U S A f D j ISO 9001 2008 Copyright 2005
3. ositioning the tip of the flexible probe near the area to be tested 4 An increase in the relative concentration of gas is indicated by the visual alarm s LED blinking faster and the audible alarm s beep rate increasing 5 Once the presence of the gas has been confirmed the instrument s sensitivity can be lowered by double pressing the ON OFF button a decreasing frequency tone should be heard allowing the location of the leak to be easily pinpointed Replacement Parts Replacement parts can be obtained by contacting one of Bacharach s Sales Service Centers listed on the back cover of this manual Item Part No Sensor 0019 0575 Sensor Cover 0019 0576 Battery Door 0019 0577 Replacing the Sensor Replace the sensor if a sensor error occurs Visual Alarm LED flashing green and red or when the instrument can no longer detect a known source of combustible gas 1 Turn instrument OFF Align tab on sensor with notch in socket Pull off sensor cover 2 3 Pull out old sensor and discard Combustibles Sensor 4 Plug in new sensor being sure to align tab on sensor with notch in sensor Sensor Cover socket 5 Install sensor cover Sales Service Centers United States Bacharach World Headquarters 621 Hunt Valley Circle New Kensington PA 15068 Phone 724 334 5051 Fax 724 334 5723 Email help MyBacharach com Canada Bacharach of Canada Inc 20 Amber Street Unit 7 Markham Ontario LR 5P
4. ry Door One Button Control e Press once for half second to turn instrument ON e Press and hold for 2 seconds to turn instrument OFF e Double press to toggle sensitivity between high and low Features e Compact Gas Leak Detector The Leakator Jr detects and pinpoints combustible gas leaks in commercial residential and industrial applications including surveying gas pipelines Wide Variety of Combustibles Detected Acetone Acetylene Benzene Butane Ethanol Ethylene Oxide Gasoline Hexane Hydrogen Industrial Solvents Iso Butane Methane Methanol Paint Thinners Propane Natural Gas and Naptha Compact and Ergonomic Design Simple one button control allows the user to hold and operate the instrument in one hand The flexible probe with sensor located at the tip allows leaks to be found in tight spaces Leak Indication The relative concentration of the combustible gas present is indicated by the frequency of the audible and visual alarms Automatic Self Check The instrument automatically performs a self check during warm up when turned ON in fresh air e Selectable Sensitivity High and low sensitivity mode selectable by a double press of the ON OFF button Pinpoints concentrations as small as 20 ppm in the high sensitivity mode e Power Four disposable AA alkaline batteries provide a minimum of 14 hours of operation A low battery indicator warns the user when the batteries need replaced The instrumen
5. t will also automatically turn itself OFF after a period of non use to preserve battery life e UL 913 Classified Intrinsically safe for Class Division 1 Groups A B C and D e Sensor Error Indicator e Low Power Metal Oxide Sensor e Microprocessor Controlled Circuitry SPECIFICATIONS Leakator Jr instrument housed in a molded ABS plastic case pacha ee omens including 4 AA batteries cloth case sensor and instructions Power Four AA alkaline batteries 14 hour typical battery life Warm Up Time Automatic self check approximately 60 seconds to operational condition Low power metal oxide sensor Self storing 12 inch 30 48 cm flexible probe Sensitivity 20 ppm in high sensitivity mode Methane Based 50 ppm in low sensitivity mode Visual Ultra bright variable frequency LED taue CIE SIONS Audible Variable speed ticking sound Operation 32 to 104 F 0 to 40 C Temperature Range 6H x 2W x 1 5D inches 152 x 51 x 38 mm Weight 6 oz 0 17 kg with batteries UL 913 intrinsically safe for Class I Division 1 Groups A B C and D hazardous locations CE Mark 2 year full warranty on instrument Safety Approvals Testing For a Gas Leak 1 Turn instrument ON and allow it to warm up approximately 60 seconds 2 The instrument is ready to check for gas leaks after the audible alarm begins to beep Note that the instrument starts in its high sensitivity mode 3 Check for the presence of gas by p