Home

G-3 Series Gateway User Manual

image

Contents

1. 8 13 VIEW SYSTEM DATA ONLINE 8 14 NETWORK CONFIGURATION 9 15 TROUBLESHOOTING J T 9 16 SPECIFICATIONS ricco cete eec ecce toc aoc 10 17 DECLARATION CONFORMITY 11 18 0 4 Sus usaq 13 Smaa support omnisense com 1 805 340 9625 1 Support Thank you for your purchase of OmniSense wireless remote monitoring equipment Support is available from your distributor or directly by email or phone shown on the top of each page If you are frustrated call us We want you to be a really happy customer 2 Overview The G 3 series gateway is compatible with all OmniSense and GE HygroTrac sensors This manual describes how to get your G 3 gateway online and begin monitoring 3 What is Included G 3 series Data Acquisition Gateway Detachable Antenna with RP SMA connector for Sensor Communication Detachable Antenna with RP SMA connector for Cellular Communication G 3 C x models only USB Power Supply 5VDC 1 0Amp US EU or UK plugs available Ethernet Cable Instruction Manual 4 Identifying Gateway Model Number and ID WiFi SSID OmniSense Web URL http omnisense username root password c170ae36 Gateway ID c170ae36
2. BI Address a0 f3 c1 1 1 3543000215 79988 36 1 OmniSense G 3 Series Gateway support omnisense com 1 805 340 9625 e ommntsanss 5 Powering up the G 3 Gateway e Connect power using the supplied USB power supply e The Internet LED will flash while the gateway is powering up e Screw antenna s finger tight Do not over tighten A 6 Status LEDs and Their Meaning The G 3 has useful status LEDs as shown in Figure 1 LEDs e POWER when on indicates power is ON e CELLULAR FLASHES when receiving a cellular signal Flash rate varies to indicate signal strength Faster is better signal slower is worse signal e WiFi ON when WiFi is enabled blinks to indicate data activity e WAN LAN ON when Ethernet is enabled blinks to indicate data activity e INTERNET When FLASHING indicates gateway is powering up When ON indicates the G 3 has a working internet connection When OFF the G 3 does NOT have a working internet connection f its NOT ON the gatewa is NOT ONLINE STATUS LEDS 7 ON a Data Acquisition Gateway G 3 Series WAN LAN CB 802 11 b g n 3G 4G 10 100 Mb s WWW omnisense com INTERNET Figure 1 LEDs OmniSense G 3 Series Gateway Page 2 Smaa support omnisense com 1 805 340 9625 7 Accessing G 3 Management Web Page As a general warning you should no
3. roi G 3 Series Gateway User Manual OmniSense LLC 72 Sams Point Road Ladys Island SC 29907 USA http www omnisense com support omnisense com 1 805 340 9625 1 843 522 0350 Revision 1 0 Released 5 7 2013 Table of Contents 1 SUPPORT iiti coe m causan vie ce 1 2 OVERVIEW rede etre a 1 3 WHAT IS INCLUDED 1 ccccscce u u u 1 4 IDENTIFYING GATEWAY MODEL NUMBER AND ID 1 5 POWERING UP THE G 3 2 6 STATUS LEDS AND THEIR 2 7 ACCESSING G 3 MANAGEMENT WEB PAGE 3 8 CONNECTING G 3 GATEWAY TO THE INTERNET 5 8 1 WIRED ETHERNET INTERNET CONNECTION 5 8 2 WIFI INTERNET CONNECTION eese 5 8 3 G 3 C x 3G CELLULAR DATA INTERNET CONNECTION 6 8 8 1 G 3 C GSM Using provided SIM 6 8 4 G 3 C GSM INSERTING YOUR OWN SIM CARD 6 8 5 GSM CONNECTION 6 0 7 9 USING G 3 GATEWAY IN DATALOGGING MODE 7 10 CREATE A MONITORING ACCOUNTT 8 11 ASSIGNING GATEWAY S TO A JOB SITE 8 12 INSTALLING SENSORS
4. and workmanship for 12 months from the date of shipment Products not subjected to misuse will be repaired or replaced OmniSense LLC reserves the right to make changes without further notice to any products herein OmniSense LLC makes no warranty representation or guarantee regarding the suitability of its products for any particular application nor does OmniSense LLC assume any liability arising out of the application or use of any product or circuit and specifically disclaims all liability without limitation for consequential or incidental damages The foregoing warranties are exclusive and in lieu of all other warranties whether written oral implied or statutory No implied statutory warranty of merchantability or fitness for particular purpose shall apply Page 13 OmniSense G 3 Series Gateway
5. idea to write this down this same information will be available on the OmniSense web site s gateway detail page should you need it 8 5 GSM Connection Status e The rate at which the Cellular LED flashes varies with signal strength and faster is better e The Internet LED comes on when a connection with the OmniSense server has been successfully made e more detailed connection status is available on the G 3 Management Web Page which is accessed as described in section 7 9 Using G 3 gateway in Datalogging mode The G 3 Gateway always operates in Datalogging mode if it has no internet connection In this mode no internet connection is required when collecting data and all sensor readings are stored in the local FLASH drive To upload the saved data to our server the Gateway will require an internet connection Once it has an internet connection the stored data is automatically uploaded to our server The time to upload all data varies depending on the amount of sensor readings being uploaded and the speed of the internet connection Data is uploaded oldest readings first By Page 7 OmniSense G 3 Series Gateway support omnisense com 1 805 340 9625 KCJOTINTISC default the Gateway store 262 144 readings after which oldest readings are overwritten This can be increased to more than 32M readings if required 10 Create a Monitoring Account If you already have an account you do not need to create a new account T
6. ction 15 and or our web site forum at shop omnisense com for A troubleshooting tips Wired Ethernet Internet Connection Typically this is zero configuration and you do not need to access the G 3 Management Web Page when using a wired Ethernet connection Connect the gateway s WAN LAN Ethernet port using the supplied Ethernet cable to your LAN router cable modem DSL modem etc to establish an internet connection You should see the WAN LAN Link LED go on solid or blinking WiFi Internet Connection login following instructions in section 7 Mouse over the Network drop down menu and click on WiFi click Scan and you should see a list of available wireless networks Click Join Network for the network you wish to join If the network you are joining uses wireless security then on the next page Join Network Settings enter the WPA passphrase then click Submit On the next page do not change any of the default settings Scroll down to the bottom and click Save amp Apply Page 5 OmniSense G 3 Series Gateway support omnisense com 1 805 340 9625 ommntsanss e When the page finishes reloading the Status field shows you are connected if the signal strength is greater than 096 8 3 G 3 C x 3G Cellular Data Internet Connection 8 3 1 G 3 C GSM Using provided SIM card If your G 3 C GSM came with a SIM card it will power on and connect to the internet with zero configuration 8 4 G 3 C GSM Inserting you
7. ge OmniSense G 3 Series Gateway Page 8 omnBenso support omnisense com 1 805 340 9625 e To view Gateway Status e From the Job Sites page click on Gateways to go to the gateways page e Click on a gateway ID to open a new window with details about that gateway 14 Network Configuration e WiFi By default the G 3 s WiFi is configured as an Access Point also known as master with a DHCP Server using 192 168 1 x address range You can configure the WiFi interface as a simultaneous WiFi Client as described in section 5 and still connect to the G 3 as an access point e Hard Wired Ethernet The G 3 automatically acts as a DHCP Server with 10 168 1 98 if no other DHCP server is detected on the network or it will automatically act as a DHCP client if a DHCP server is detected 15 Troubleshooting PROBLEM SOLUTION Cellular LED Blinking you If you are using your own SIM have signal but Internet card check your APN LED never comes on not Username and Password getting internet connection settings After changing settings you Restore factory default settings can no longer access your by pressing the reset button for gateway 20 seconds or until ALL LEDS blink on then off When connected to a Your network is blocking building LAN via wired or internet access Contact your IT wireless Ethernet the department and ask them to Internet LED never comes enable access on The network uses a Proxy Configure the p
8. he OmniSense G 3 gateway can be used with existing GE HygroTrac accounts however all new accounts should be opened on the OmniSense Web site e go to http www omnisense com hover your mouse over My Account then click create new account e fill in the form to create your account making sure you select the pricing plan that fits your use model e You will be prompted to create a new job site Fill in the form that describes the site you wish to monitor 11 Assigning Gateway s to a job site e after completing the site setup in step 1 you will be on the My Account page Click on jobs Sites to go to your job sites and you should see the job site you just created e Click on the Gateways link on that page to manage the gateways assigned to that job site e Click on the Add a new gateway button e Enter the Gateway ID found on the bottom label of the G 3 gateway and a description and click Save 12 Installing Sensors There are too many variables to address in this guide however case studies of typical sensor installations can be seen here http shop omnisense com blog 13 View System Data Online e Login at http www omnisense com e Click on Jobs Sites to go to the job sites page e To View Sensor Data e From the Jobs Sites page click on Sensors to go to the sensors page e Click on any sensor reading to view a graph of that data e Note you may have to wait up to 5 minutes for a sensor to show up on the sensors pa
9. r own SIM card If your G 3 C GSM did not come with a SIM card follow these instructions for inserting your SIM card and configuring your connection e Accessing the USB Stick MODEM 1 Open the gateway case by removing the 4 screws on the bottom of the gateway 2 Loosen two red thumb screws 3 Remove USB Stick MODEM to allow for access to SIM slot e Inserting the SIM Card see Figure 3 Inserting the SIM a Skip step 1 since the cap is already removed Pull out the SIM card holder Insert your SIM card into the holder as shown Place the SIM card holder with the fitted SIM back in your USB modem Pon gt Figure 3 Inserting the SIM Card OmniSense G 3 Series Gateway 6 A fy omisso support omnisense com 1 805 340 9625 e Reassembly Insert USB Stick in its original position Make sure it is fully inserted Tighten two red thumb screws finger tight make sure Antenna connector is fully seated Close gateway case insert 4 screws into bottom of case and hand tighten e Configuring GSM Connection Login following instructions in section 7 Click on Network Click on Edit for the WAN 3G interface Enter the APN and optionally the PIN Username and Password Click Save amp Apply at the bottom of the page After about 30 seconds you should see the status show n miki as well as see signal strength the carrier name i e T Mobile and other SIM and MODEM information While its a good
10. roxy server IP Server address on the OmniSense Settings web page Page 9 OmniSense G 3 Series Gateway support omnisense com 1 805 340 9625 amp omniSanse 16 Specifications Description Specification Power 100 240 VAC input USB power 5 0 VDC 1 0 Amp 5 supply with Mini Watts output B type connector maximum 190 x 125 x 40 mm Antenna s Weight 113 002 429g Mounting Options Desktop Wall or ceiling using 2 built in teardrop mounting eyes Oo 3G Cellular on G 3 Huawei E160G USB US models come C GSM models MODEM with T Mobile SIM Card directional 2 dBi gain Cellular Antenna on RP SMA omni G 3 C GSM models directional 2 dBi gain RF power RF frequency 928 MHZ RF frequency EU MHz band models Datalogging Memory Default 262 144 Contact us to readings 32M increase limit possible OmniSense G 3 Series Gateway Page 10 A fy Omas support omnisense com 1 805 340 9625 17 Declaration of Conformity We OmniSense LLC 72 Sams Point Road Ladys Island SC 29907 declare under our sole responsibility that the OmniSense Monitoring System to which this declaration relates is in conformity with the following standards For US and Canada Models Only FCC Part 15 This Product Contains Transmitter Module FCC ID RY20002 and Transmitter Module FCC ID TE7MR3020 This equipment complies with Parts 15 of the Federal Communications Commission FCC rules for the United S
11. s since gateway was turned on Bookmark this page for easy access Page 3 OmniSense G 3 Series Gateway support omnisense com 1 805 340 9625 onmisense OmniSense 4 Authorization Required Please enter your username and password Username root Password Login Reset Status OmniSense Server NLINE Active Sensors 56 Network Cellular Connection Status 3g Signal Strength 50 wan_3g Carrier 310260 SIM SIM READY MODEM HUAWEI E160G ESN IMEI 354300021579988 Figure 2 G 3 Management Login Web Page OmniSense G 3 Series Gateway Page 4 A fy onmia support omnisense com 1 805 340 9625 8 Connecting G 3 Gateway to the internet To view your data in real time your gateway must have a internet connection The G 3 can connect using Cellular on G 3 C models WiFi or hard wired Ethernet connections Follow the steps in this section to connect the G 3 to the internet To use your G 3 gateway in datalogging mode see section 9 8 1 power on gateway as described section 5 follow the steps in either section 8 1 8 2 or 8 3 depending on your method of connecting to the internet to establish an internet connection If you have a internet connection then after a delay of up to 60 seconds you should see the Internet LED go on solid if the Internet LED does not go on the gateway is not talking to our server and your internet connection is not working Check the troubleshooting guide in se
12. t change any settings outside of what is described in this manual You can restore factory defaults by holding down the reset button for 20 seconds The G 3 has a built in web server which serves up the management web pages The management web server can be accessed directly using any PC tablet or smart phone To connect to the G 3 Management Web Page you must connect your PC smart phone or tablet directly to the G 3 using either WiFi or hard wired Ethernet e Power on gateway and wait for the Internet LED to stop blinking e to connect using WiFi e From your PC tablet or smart phone scan for available wireless networks e Connect to SSID OmniSense e to connect using hard wired Ethernet e Connect G 3 Gateway s WAN LAN port to your PC s Ethernet port using Ethernet cable e You should see the WAN LAN Link LED go on solid or blink e open web browser and enter http omnisense in the address field e You should then see a login page see Error Reference ource not found prompting for username and password Use the default username and password from the label on the bottom of the gateway default username is root and the default password is the gateway ID Note password and username are case sensitive and all letters are lower case e From the login page with no username or password required you can quickly get useful status like current cellular signal strength and number of active sensor
13. tates Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device The equipment has been tested and found to comply with part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet or on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Page 11 OmniSense G 3 Series Gateway support omnisense com 1 805 340 9625 Sonne FCC Part 15 Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance co
14. uld void the user s authority to operate the equipment Industry Canada IC This Product Contains Transmitter Module IC ID 6474A 0002 This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of Industry Canada This device complies with Canadian RSS 210 regulations NOTICE The Industry Canada IC label identifies certified equipment The Department does not guarantee the equipment will operate to the user s satisfaction For EU Models Only Data Acquisition Gateway The G 3 Series Gateway is in conformity with the following standards e EN55022 2006 A1 2007 e EN 55024 2010 e EN60950 1 2006 11 2009 A1 2010 A12 2011 following the provisions of the 2004 108 EC Electromagnetic Compatibility as amended and 2006 95 EC Low Voltage Directive as amended Sensors The Sensor Module is in conformity with the following standards 220 3 V1 1 1 2000 09 EN301 489 3 V1 4 1 2002 08 following the provisions of the Radio Equipment and Telecommunications Terminal Equipment R amp TTE directive Directive 1999 5 EC Par Chris Hoogenboom President OmniSense LLC Ladys Island May 7 2013 OmniSense G 3 Series Gateway Page 12 A fy omisso support omnisense com 1 805 340 9625 18 Warranty OmniSense LLC warrants its products against defects in material