1. 10 View Alarm Memory 10 Reset Smoke Detectors 10 Managing Phone 12 Communicator Test Function 12 Set System Dale I Gu hoe Pun RISE CHUA 13 Set Systeni Clock ie c Rc ORTU RR PPS RC he ee 13 Set Gode Pad Tore osse bee Hber Gan dead alg echoed ade eri eee 13 Code Pad Control Tones 14 Emergency Evacuation Plan 15 GLOSSARY OF TERMS Abort Delay An option that allows a delay in reporting to the central station Authority Level The level of access an individual has when using an alarm panel Central Station Location where alarm data is sent during an alarm report Chime Feature An option that allows the code pad to sound a ding dong whenever an entry exit door is opened Codes Can be either User Codes relating to a person or Function Codes a toggle Switch to turn specific functions on off NOTE A system may have a maximum of eight 4 digit codes or eight 6 digit codes but not a mixture of both Duress Code An option that allows a special code to be sent to the central station that indicates the alarm system is being operated under duress Forced Arming An op
2. Step 5 Press to end and exit DELETING TELEPHONE NUMBERS When pager or siren tone formats are selected any of the three phone numbers may be deleted in the run mode You must use the following procedure to delete the phone numbers Step 1 Press the r key Step 2 a Press the 4 1 key For phone number one 1 Step 2 0 Press the 4 2 key For phone number two 2 Step 2 c Press the 4 3 key For phone number three 3 Step 3 Enter a Master Arm Disarm Code Step 4 Press the BYPASS key Step 5 Press to end and exit TEST FUNCTION Optional If programmed this function will perform a battery test communicator test and a siren test No alarms will be sent and no reports will be sent unless the communicator test is enabled Step 1 Press the r key Step 2 Press the 4 4 key The test will be performed as programmed Step 3 If the siren test is performed enter a user code to silence the siren No alarms will be sent and no reports will be sent unless a communicator test is performed at which time a test signal will be sent 13 SET SYSTEM DATE Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Press the r 9 6 Enter the Master Code Enter the Day of Week 1 Sunday 3 Tuesday 5 Thursday 7 Saturday 2 Monday 4 Wednesday 6 Friday Enter the Month Code This must always be two 2 digits 01 January 05 May 09 September 02 February 06 June 1
3. user code Note To delete a user code enter Chime Chime Chime Chime for a 4 digit code or Chime Chime Chime Chime Chime Chime for a 6 digit code Step 7 The ready light will flash indicating you are back at Step 5 above If the code is rejected the sounder will beep 3 times Step 8 If another user code needs to be programmed return to Step 6 Press the key while the ready light is flashing to exit the User Code Programming Mode ASSIGNING USER CODE AUTHORITY LEVELS Assign authority levels to users by following the steps below Assign user codes before assigning authority levels Step 1 Press the r 6 keys Step 2 Enter a Master Arm Disarm Code NOTE Someone changing the authority of another person can only add or remove authorization if they have access to that same authority level Step 3 The ready light will flash Step 4 Enter the 2 digit user number to be assigned authority The ready light is constant and the partial light will flash Step 5 Lights illuminated indicate the authority levels assigned to this code An explanation of the lights is listed below You may toggle turn on off the authority level by pressing the number for that authority level LIGHT AUTHORITY LEVELS IF LIGHT 8 15 LIGHT AUTHORITY LEVELS IF OFF LIGHT 8 IS OFF Reserved Note Do not change if on Arm Only 6 Bypass Zones Arm Only After Close Window Open Close Reporting Master Arm
4. ul ZONE LOW BATTERY Press the 3 key The zone light s will illuminate showing which zone s has a low battery This only applies to wireless zones Press the key to return to the 1 of 8 service lights ZONE LOSS OF SUPERVISION Press the 4 key and the zone light s will illuminate showing which zone s has loss of supervision This only applies to wireless zones Press key to return to the 1 of 8 service lights ZONE TROUBLE Press the 5 key and the zone light s will illuminate showing which zone s has a trouble condition Press the key to return to the 1 of 8 service lights RESERVED 7 FAILURE TO COMMUNICATE This light will illuminate when there is a failure to communicate between your system and the central station LOSS OF SYSTEM TIME This light will illuminate when there has been a loss of power and your system clock needs to be reset Instructions are on page 13 exit the Service Light Mode press the key EMERGENCY ACTIVATION KEYS NOTE You must hold these keys for 2 seconds to activate these functions Your system may not be programmed for these activation keys see page 1 You should press these keys only an emergency situation that requires response by emergency personnel If your system is programmed for these functions the following reports can be sent Fire Key This key can activate the fire alarm when pressed for two seconds If your system is connected to a mo
5. 7 31 98
6. Code Pad includes up to 35 lights and a built in electronic sounder These provide specific information relating to the status of the security system which is described in the booklet Understanding what the lights and sounds mean will help you to easily operate your system READ THE ENTIRE MANUAL AND IF POSSIBLE PRACTICE ON THE CODE PAD CONTROL WHILE YOUR PROFESSIONAL INSTALLER IS ON SITE KEEP IN MIND THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY TO THE FOLLOWING MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY SECURITY PLAN FOR YOUR HOME BUSINESS 1 Your security system is an electronic device and is subject to failure or malfunction Do not rely on it as your single source of security 2 system should be tested weekly 3 Your system will not work without power 4 Warning devices will need to be loud enough wired correctly and properly placed to provide notification of an alarm event 5 Smoke and heat detectors may not detect heat and smoke in all situations 6 Use qualified security professionals to install and maintain your security system 7 It may be possible to arm the security system without the backup battery connected Your periodic
7. Disarm can program other If this light is on Press codes to exit Step 6 Press the r r This returns you to Step 3 At this point you may enter another user number to assign authority level Repeat Steps 4 6 until you have assigned authority levels to all user numbers Step 7 Press the key to exit the Assigning Authority Level Program 10 VIEW ALARM MEMORY Step 1 Press the r key Step 2 Press the 3 key Step 3 The ALARM MEMORY feature will flash those zones that created alarms and will light steady those zones that were bypassed during the last alarm RESET SMOKE DETECTORS This function is used to reset Smoke Detectors Zone Troubles and Zone Tampers Step 1 Disarm the system if not disarmed Step 2 Press the r key Step 3 Press the 7 key Reset has now been performed Step 4 If the code pad begins beeping the reset did not execute properly Enter your code to silence the code pad Wait a few minutes and repeat step 2 to attempt another reset If the code pad still beeps after repeated attempts please contact your installer 11 USER PROGRAMMABLE TELEPHONE NUMBERS When pager or siren tone formats are selected any of the three phone numbers may be programmed or altered in the run mode You must use the following procedure to enter the phone numbers Step 1 Press the r key Step 2 a Press the 4 1 key For phone number one 1 Step 2 0 Press the 4 2 key For phone numbe
8. 0 October 03 March 07 July 11 November 04 April 08 August 12 December Enter the Day Code This must always be two 2 digits Example The 5th would be entered as 0 5 Enter the last two digits of the Year Code Example For 2000 enter 0 0 SETTING THE SYSTEM CLOCK Step 1 Step 2 Step 3 Step 4 Step 5 Press the r key Press the 9 7 keys Enter the Master Code Enter the hour code which must be two 2 digits Note The clock is a 24 hour clock Example 12 00 am would be entered as 0 0 7 00 am would be entered as 0 7 and 5 00 pm would be entered as 1 7 Enter the minutes code which must be two 2 digits Example 7 minutes after would be entered 0 7 SETTING CODE PAD TONES Step 1 Press the r 0 keys Now the code pad is in the Adjust Tone mode Step 2 Pressing the 1 key will adjust the code pad sounder to a higher tone Pressing the 2 key will adjust the code pad sounder to a lower tone Step 3 When the desired tone is reached press the key to set this tone and exit the Adjust Tone mode WALK TEST MODE Step 1 Press r Chime Step 2 Enter a Master Arm Disarm Code Now all zones become 24 hour silent and local non reporting zones By faulting any zone that zone will latch its zone light on the LED code pad and sound the Chime The Chime will continue to sound each time a zone is faulted Once all zones are tested z
9. SECURITY SYSTEM NOTES Installing Service Company For Service Call Installation Date Central Station Duress Code EMERGENCY ACTIVATION KEYS check if enabled Fire QO Auxiliary Emergency Police PROGRAMMED FUNCTIONS Auto Arming Forced Arming Quick Arm Chime Group Bypass Re Exit Communicator Test Partial Arm Uni Arm Fire Alarm Verification ENTRY EXIT DELAY TIMES Exit Delay Time Secondary Exit Delay Time Entry Delay Time Secondary Entry Delay Time Partial Delay Time ZONE DESCRIPTIONS 01 05 02 06 03 07 04 08 THIS MANUAL IS PROVIDED TO HELP YOU UNDERSTAND YOUR SECURITY SYSTEM AND BECOME PROFICIENT IN ITS OPERATION ALL USERS OF YOUR SECURITY SYSTEM SHOULD READ AND FOLLOW THE INSTRUCTIONS AND PRECAUTIONS IN THIS BOOKLET FAILURE TO DO SO COULD RESULT IN THE SECURITY SYSTEM NOT WORKING PROPERLY THIS BOOKLET SHOULD KEPT IN AN ACCESSIBLE LOCATION FOR THE LIFE OF THE SECURITY SYSTEM IF YOU DO NOT UNDERSTAND ANY PART OF THIS MANUAL YOU SHOULD NOTIFY YOUR INSTALLING COMPANY The SECURITY CONTROL can be turned on ARMED and off DISARMED by entering a 4 or 6 digit code into the Code Pad Control which is similar to a telephone Code Pad If your Security Control has been so programmed you may be able to turn on ARM your System by simply pressing the ON or PARTIAL key The system should always be disarmed using a 4 or 6 digit code The LED
10. f a zone s being faulted Zone Light The zone lights are off when everything is normal A zone light will be on if the zone has been bypassed If a zone light is flashing that zone is in alarm or has been faulted If a zone light is flashing rapidly it means that the zone is a trouble condition Trouble conditions are Tamper Hardware Wireless Sensor Wireless Sensor Low Battery Loss of Supervision A combination of Alarm Fault and Tamper Trouble will produce a rapid flashing light for a short period of time followed by a slow flashing light SERVICE MENU The service light will be on if the security system requires service If the service light is on press the r key followed by the 2 key to determine the service condition One or more zone lights will illuminate indicating what service s is required Call your service provider immediately for these problems Below is a listing of what each light means in a service condition LIGHT PROBLEM SYSTEM FAULT Press the 1 key The zone light s that is illuminated corresponds to the system fault s below Over Current Fault Expander Low Battery Siren Trouble Expander Box Tamper Box Tamper Expander Trouble Expander Power Reserved Press the key to return to the 1 of 8 service lights ZONE TAMPER Press the 2 key and the zone light s will illuminate showing the zone s that is tampered Press the key to return to the 1 of 8 service lights
11. nd exit lights will illuminate You may now leave the building Note The exit light will flash rapidly for the last 10 seconds of the exit delay as a warning to the user that the exit time is about to expire The user may wish to press the Exit key to start the exit delay again or disarm and rearm the system if more time is needed ARMING SYSTEM IN PARTIAL MODE PARTIAL is used when the user is inside the premise and wants protection around the perimeter Listed below are the steps to arm in the PARTIAL Mode Step 1 Close all protected doors and windows Ready light must be on or flashing when all protected zones and sensors are secure NOTE If any zones are bypassed a sensor in that zone can be violated without affecting the ready light The security system will not arm if the ready light is not on or flashing If the power light is off you have no AC power Restore power if possible If not contact your installation company listed on page 1 of this booklet for service Press the Partial key bypass light will illuminate if any zone s is bypassed The light s corresponding to the bypassed zone s will illuminate alerting the user that a zone s may be unprotected and can be faulted without an alarm USING THE QUICK ARM Optional if programmed see page 1 The Quick Arm feature may be used if it is enabled Quick Arm will allow the user to arm the security system in the ON mode by pressing the ON key The s
12. nitoring centre an emergency report could be sent to that centre Auxiliary Emergency Key This key can activate the auxiliary alarm when pressed for two seconds If your system is connected to a monitoring centre an emergency report could be sent to that centre Police Panic Hold Up Key This key can sound a local audible alarm when pressed for two seconds If your system is connected to a monitoring centre an emergency report could be transmitted to that centre NOTE Some Panic Hold Up alarms are programmed to be silent at the protected site while reporting an alarm to the monitoring centre Check with your installation company to determine how your security system will respond to the Panic Hold Up activation CODE PAD FUNCTIONS ARMING YOUR SYSTEM IN THE MODE ON is used when the user is away from the premise and wants the interior protected Listed below are the steps to arm in the ON Mode Close all protected doors and windows Ready light will be on or flashing when all protected zones and sensors are secure NOTE If any zones are bypassed a sensor in that zone can be violated without affecting the ready light The security system will not arm if the ready light is not on or flashing If the power light is off you have no AC power Restore power if possible If not contact your installation company listed on page 1 of this booklet for service Enter your 4 or 6 digit user code to arm the system The armed a
13. o pe aed bie UR 5 Bypass Light oro pee quete egeo eter een 5 Chime Light ien eulx ee ea el EPI n 5 ExitElglil erum etie esos idt ets 5 Fire LiQht iue eoe epu eo a hoe ee e Rte ee 5 Or Light ete a See me eR v uber tubus vue 5 Partial Eight euis tui bh PD Spb SHEER bee laa eee eet 5 Power Eight ERE Rech ps dedere E RENE 5 Ready hight 5 Zone Light cse RR ee Ree ee 5 SERVICE 2 eet ies ee ELE NO estu 6 EMERGENCY ACTIVATION KEYS 7 CODE PAD FUNCTIONS 22sec ese ane bd bee dee bade bbe eda bene 7 Arming in the On Mode 7 Arming System in Partial Mode 8 Using the Quick Aim 12 m ir Leere pesa kis ham ads meg 8 Disarming the System 8 Bypassing Debbie e erdt 8 sek edn ge be dE INIRE EUER Ui 9 Group Bypass dod idet Ren fedi aes 9 Turning the Door Chime On and Off 9 CHANGING CODES 9 ASSIGNING USER CODE AUTHORITY 9 OTHER CODE PAD FUNCTIONS
14. onal Fire Protection Association and can be used as a guide in establishing an evacuation plan for your building Draw up a floor plan of your home Show windows doors stairs and rooftops that can be used for escape Indicate each occupant s escape routes Always keep these routes free from obstruction Determine two means of escape from each room One will be the normal exit from the building The other may be a window that opens easily An escape ladder may have to be located near the window if there is a long drop to the ground below Set a meeting place outdoors for a headcount of the building occupants Practice escape procedures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot Call the Fire Department from a neighbour s phone Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms BEDROOM BEDROOM DINING E LIVING BEDROOM ROOM ROOM BEDROOM O0 FIRST FLOOR yy SECOND FLOOR FRONT 4 y BACK 16 FOR SERVICE CONTACT NX4 LED CODE PAD NX4DASUA98 REV A
15. one lights lit on the LED code pad go to Step 3 Step 3 Press a Master Arm Disarm Code 14 CODE PAD CONTROL TONES BEEPS WO N s o 10 11 12 Beeps for all keypresses Sounds a continuous tone during the entry delay time Pulses when a day zone is violated while the system is disarmed Pulses when a fire zone has a trouble condition Beeps times for trying to arm with the Ready light off if Force Arming has not been selected Beeps for 1 second or emits a ding dong sound for the Chime feature Beeps during an exit delay beeps rapidly for the last 10 seconds of an exit delay and beeps 1 second at the end of the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any zone s is bypassed Pulses when the armed status changes and a low battery is detected Pulses when the armed status changes and a tamper condition is detected Beeps to indicate telephone line cut if selected Pulses when one or more of the following conditions are detected zone or box tamper low battery ac power fail or expander trouble Entering a valid code will silence the code pad sounder when it is pulsing Please contact your installer if a trouble condition exists 15 EMERGENCY EVACUATION PLAN An emergency evacuation plan should be established for an actual fire alarm condition For example the following steps are recommended by the Nati
16. r two 2 Step 2 c Press the 4 3 key For phone number three 3 Step 3 Enter a Master Arm Disarm Code Step 4 Now enter the required number not exceeding 20 digits Use the following table to determine Key values om cup de Spr 9nd m gt o o 9 8 o ON S6 p e a Poa ig s 45 ig e veas Dae Step 5 Press to end and exit VIEWING TELEPHONE NUMBERS When or siren tone formats are selected any of the three phone numbers may be viewed in the run mode You must use the following procedure to view the phone numbers Step 1 Press the r key Step 2 a Press the 4 1 key For phone number one 1 Step 2 b Press the 4 2 key For phone number two 2 Step 2 c Press the 4 3 key For phone number three 3 Step 3 Enter a Master Arm Disarm Code Now you are in the view mode and the first phone digit will be displayed Use the following table to read the code pad lights Go to step 4 to view the rest of the phone number Step 4 Press the r key to move to the next digit 12 Use the following table to determine Key values Eme 7 emet o ones 2 img 9 ores Oo Eee Sw Eos s Eos 5 4 ones 5 Pulse Dialing goes 9
17. r zone s that need to be bypassed Step 7 Press the BYPASS key again or press the key to exit the Bypass Mode Bypass light will stop flashing upon exiting the Bypass Mode UN BYPASSING To manually un bypass zones perform the bypassing procedure on a zone that is already bypassed The corresponding light for that zone will go off when un bypassed NOTE All zones will automatically be un bypassed each time the system is disarmed GROUP BYPASS By pressing the BYPASS key followed by the 0 0 key then the BYPASS key again all zones that are designated as group bypass zones will be bypassed Now you can arm your System in either the ON or PARTIAL mode Once armed and the bypass toggle feature is enabled press the BYPASS key again to exit group bypassing TURNING THE DOOR CHIME ON AND OFF The door chime is turned on or off by pressing the CHIME key while the system is in the disarmed state If the chime is on the chime light will be illuminated If the chime is off the chime light will be off Each press of the CHIME key will toggle the chime feature on off and produce a momentary ding dong sound CHANGING USER CODES Step 1 Your system must be in the Disarmed state to change user codes Step 3 Erter a master Arm Dearm Coas Enter the 2 digit user number always enter 2 digit such as 0 3 for user 3 or 5 2 for user 52 Enter the new four 4 or six 6 digit
18. rm cycle Bypass Light The bypass light is when any zone is bypassed The zone s that is bypassed will also be illuminated If the bypass light is off no zones are bypassed Chime Light The chime light is when the chime feature is on off otherwise Exit Light The exit light is on during the exit delay Please note that the light will flash during the last 10 seconds of the exit delay as a warning that the time is running out The user may want to restart the exit delay if the exit light is flashing in order to prevent an alarm The user may then press the Exit key to restart the exit delay before the delay expires Fire Light A steady fire light means a fire zone has been faulted A rapidly flashing fire light means that a fire zone is in a trouble condition On Light The on light is on when the system is armed The on light is off when it is disarmed Partial Light The partial light is on when the system is armed in the Partial Mode All non bypassed zones will be delayed and follow the Partial delay time When armed in Partial Mode the Arm On and Bypass lights will also be on Power Light The power light is on if the primary power is on The power light will flash if the system has a low battery condition Ready Light The ready light is when the system is ready to arm and flashes if ready to force arm The ready light is off when the system is not ready to arm because o
19. test should be done with A C Power removed to verify the battery is connected and adequately charged 8 Care should be taken to plug in and restrain the A C Transformer after testing PLEASE READ THE FOLLOWING INFORMATION AND INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR SECURITY CONTROL SYSTEM IF YOU DO NOT UNDERSTAND ANY PORTION OF THIS MANUAL OR IF YOU HAVE ANY QUESTIONS ABOUT YOUR SYSTEM CONTACT THE INSTALLING COMPANY LISTED ON PAGE 1 OF THIS BOOKLET 2 TABLE OF CONTENTS GLOSSARY OF TERMS celer aed beue he ma Ret gee 4 Aboit Delay c o eto e eR ue bk E ERN REED OHNE B RCEN EE ERU 4 Authority Level 5 ehe eK gene erbe A ROT e 4 Gentral Statlori 4 Chime ea ees pe GPS euni pP S edt 4 zs cet pate neva Du dius Eel asm ye Dia cT S n URL freed 4 Duress Code oreet e eere nye ees Gee EROR RT EE 4 Forced Armlilig 4 Function Gode reve Dew XR rwiuerse WE WS E Mte ee 4 Group BYPASS aretha mie stulte m vA NAE e E TUE tdem s 4 Master Coden ascites eta xu eg VER ME a E b oe 4 Partial Atm 4 Perimeter Se ed 4 QUICK ARM Eg VER Ui S eive seu EA mE OE 4 MET MEME 4 UNDERSTANDING THE LIGHTS 5 Armed bLight sitere tee EC o
20. tion that allows the system to be turned on ARMED with one or more zones open A system that is ready to be force armed will flash the ready light Note Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass An option that allows the user to bypass multiple zones with a single operation Master Code A master arm disarm code that can program other user codes Partial Arm mode used to arm the perimeter and unused areas of an occupied premises Perimeter The outer edge of the protected area Quick Arm An option that allows you to turn on ARM the security system by pressing either the ON or PARTIAL key on the code pad control for ARMING only as programmed by the installing company Universal Arming Uni Arm When enabled your alarm system can automatically determine whether to arm in the Full mode or in the preset Partial mode by looking to see if you exit your premises or stay inside after arming your system NOTE This feature can be used in conjunction with Quick Arm User Code A four 4 or six 6 digit entry used to arm or disarm the system UNDERSTANDING THE LIGHTS Armed Light The armed light is when the system is armed The armed light is off when it is disarmed The armed light will flash when there has been an alarm during the previous a
21. ystem can be quick armed in the Partial mode by pressing the PARTIAL key This feature is used for ARMING ONLY and should not be enabled to disarm the security system This is ideal for a maid or baby sitter code etc DISARMING THE SYSTEM When you enter the protected area through one of the designated Entry Exit doors the code pad control will sound a solid continuous tone for the duration of the entry delay time or until you enter a valid code After entering a valid code the red armed light will go off and 8 the tone will stop The security system is now DISARMED f a valid code is not entered before the end of the entry delay an alarm will occur NOTE If the red armed light is flashing during the entry delay the alarm system has been activated in your absence Leave the building immediately and call your alarm company and or the police from a safe location BYPASSING ZONES If you wish to bypass one or more zones this must be done while the system is in the disarmed state The following steps are used for bypassing zones Press the BYPASS key If required optional enter user code if required optional 51 3 The bypass light flashes Enter a 2 digit zone indicating the zone you wish to bypass Example Press the 0 1 key for zone 1 press 1 2 for zone 12 Press the BYPASS key again The corresponding zone light will illuminate indicating the zone has been bypassed Repeat 4 for any othe