Home

manul cover.fm

image

Contents

1. aai 1 Finding Your Way Around 2 Connecting and Mounting 3 POWER un ai inn ded 3 Verifying Scanner Operation 3 MN pas dina 4 Connecting to the Host 6 Setting Up the Scanner gt 6 Scan 6 Seu Up sine ms tint 7 sani erven ane nenn 7 LED Indications 8 De Sucina ars 9 Changing the Beep Volume 9 Sleep Mode 9 Controlling from a Host System 10 Maintaining the Scanner 10 Specifications 11 Dimensions 13 Troubleshooting nnee 15 Introduction This Omnidirectional Laser Scan Module is an easy to inter grate unit that performs 5 directions of scan field with a 20 line scan pattern cycling at 1200 scan per second for quick accurate reads The scanner s smart small cubic design allows for easy integration into new equipment and efficiently reduces overall equipment size Multiple interfaces include keyboard RS232C USB1 1 and wand are offered at owner s convenience Unpacking The package should contain Omnidirectional Laser Scanner with cable 1 ea User s Manual Programming Guide E 5V Adaptor optional 1 ea If any package contents are damage or missing please con tact your dealer immediately Finding Your Way Around Front View _ Scan Window LED Indicator Buzzer Optical Wake up Sensor Back View Bottom View
2. scanner entering sleep mode steady orange light this indicates motor failure for mo tor failure a periodic beeping sound will also be heard flashing orange light scanner has a laser subsystem failure return to repair Beeps Beeps Status Indications one beep a barcode has been successfully decoded series of 4 beeps scanner passed self test and is operating properly when scanner is powered up series of 2 beeps when scanner is entering pro gramming mode continual beep failure indication return to repair Changing Beep Volume The scanner can be programmed with the Programming Guide to change beeper tone volume and period The default beep volume is loud There are three sound levels loud medium and low Sleep Mode After the scanner has been inactive for a period of time the laser automatically turns off after some more time the motor turns off and the scanner enters sleep mode indi cated by the red status LED blinking once a second To wake up the unit simply present an object close to the scan ner window The Sleep Mode feature is included to reduce power consumption and to extend scanner life Note The scanner includes a motion sensor that detects activity in front of the scan window The detecting distance is up to about 100mm from the scan window depending on ambient light Controlling the Scanner from a Host System The scanner can be co
3. Radiant Energy The Omnidirectional Laser Scan Module uses one low power visible laser diode operating at 650nm in an opto mechanical scanner resulting in less than 3 9uW radiated power as observed through a 7mm aperture and averaged over 10 seconds Do not attempt to remove the protective housing of the scanner as unscanned laser light with a peak output up to 0 8mW would be accessible inside Laser Light Viewing The scan window is the only aperture through which laser light may be observed from this product A failure of the scanner motor while the laser diode continues to emit a laser beam may cause emission levels to exceed those for safe operation The scanner has safeguards to prevent this occurrence If however a stationary laser beam is emitted the failing scanner should be dis connected from its power source immediately Adjustments Do not attempt any adjustments or alteration of this product Do not remove the protective housing of the scanner There are no user serviceable parts inside Caution Use of controls or adjustments or performance of proce dures other than those specified herein may result in hazardous laser light exposure Optical The use of optical instruments with this product will increase the eye hazard Optical instruments include binoculars magnifying glasses and microscopes but do not include normal eye glasses worn by the user Table of Contents Introduction 1 811 9 12 1115
4. Mounting Holes Mounting Holes Connecting and Mounting Power The scanner needs a minimum of 200mA at 5V power The power link interface cable that comes with the scanner sup ports both direct power where the scanner takes power from the host machine and external power the power adapter that s plugged into an AC outlet If the host machine sup plies power it must be the same as the input power specified 200mA 5V When external power is used the scanner does not take power from the host machine There is no on off switch on the scanner It turns on when power is connected and turns off when power is removed It is advised to turn off your POS or host system before installing the scanner to avoid electronic damage to your computer Make sure to use only AC DC power adaptor approved for the scanner The usage of other power supplies may cause damage to the product that s not covered by factory war ranty Verifying Scanner Operation Before installing the scanner follow the procedures below to make sure scanning go on properly 1 Connect the scanner with host through cable that is attached to the scanner 2 If adaptor is not required go directly to step 4 Insert the 8 pin modular plug of the power link cable into the host connector in the back of the scanner until a firm click is heard 3 Plug the power adaptor into the jack on the power link cable 4 When the scanner powers up LED light up in green and
5. FIELD 14 Troubleshooting Problem Diagnostic Tips The scanner is on but cannot read bar codes The LED is red The scanner window is dirty and must be cleaned as described in Maintenance section The presented barcode type is not enabled and must be programmed with the programming guide The host disables the scanner The barcode type presented is not supported by this module The scanner is on but the motor is not rotat ing LED is intermit tently flashing red The scanner has entered sleep mode Simply present a barcode to the scanner to activate the scanner LED is orange Possible failure of the scanning safeguard circuit Disconnect the scanner from its power source im mediately and contact your dealer The scanner does not accept more than 2 or 3 barcode labels There is no proper handshaking with the host system Switch on the host system and check connection and communication settings The scanner flashes alternating red and green LED with no motor nor pattern The scanner detects a power insert failure Please check if the power is connected properly 15 Problem Diagnostic Tips LED remains green The scanner is continuously seeing a barcode Remove all barcode la bels out of the scan volume of the scanner and try again The scanner cannot send data to the host system There is no proper handshaking between the scanner and the host Make s
6. Omnidirectio User s Manual No warranty of any kind is made in regard to this material including but not limited to implied warranties of mechantability or fitness for a particular purpose We are not liable for any errors con tained herein nor incidental or consequential damages in connection with furnishing performance or use of this material No part of this document may be reproduced transmitted stored in a retrieval system transcribed or translated into any lan guage or computer language in any form or by any means elec tronic mechanical magnetic optical chemical manual or otherwise without express written consent and authorization We reserve the right to make changes in product design without reservation and without notification The material in this guide is for information only and is subject to change without notice All trademarks mentioned herein registered or otherwise are the properties of their various respective owners Copyright 2004 All rights reserved Radio Notice This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with the instructions in this manual it may cause interference to radio communications The equipment has been tested and found to comply with the limits for a Class A computing device pursuant to EN55022 an 47 CFR Part 2 and Part 15 of the FCC Rules These specifications are designed to provide reasonable protection again
7. green UPC EAN JAN UPC Versions A amp E EAN 8 EAN 13 JAN 8 JAN 13 Addendum 2 or 5 ISBN ISSN Japa nese Bookland Code 39 with full ASCII Codabar NW7 Code 128 EAN 128 Code93 Interleaved 2 of 5 MSI Plessey China Post Code Code 32 Italian Pharmacoe Optional Industrial 2 of 5 Standard 2 of 5 Discrete 2 of 5 Matrix 2 of 5 IATA Code Code 11 RSS 14 RSS Expanded RSS Limited Programmable tone and beep time Keyboard RS 232C USB1 1 Wand 72 0mm 68 0mm 64 0mm 175g Standard 2m straight 11 Power Input Voltage Power Operating Current Laser Class EMC Environment Operating Temperature Storage Temperature Humidity Light Level Shock 5VDC 10 1 0Watts 200mA 5 0V CDRH Class Ila IEC 60825 1 Class 1 CE amp FCC DOC compliance 0 C 40 C 20 C 60 C 5 95 RH non condensing max 2500LUX fluorescent Designed to withstand 1m drops 12 Dimensions 3 M3 0 5 Deptha5 0 amp Ss 3 Unit mm inch Scan Field EN 1164 F 4 58 LE 100 0 3 94 gt 500 7 197 I I II ot 50 0 1 97 100 0 3 94 5 mil 0 127mm ii 116 4 4 58 mm in 55 10 6 mil 0 15mm 45 115 WIDTH OF FIELD 7 5 mil 0 19mm 40 14 10 mil 0 25mm l 0 20 l 13 mil 0 33mm 100 UPC EAN o 0 21 H 26 mil 0 66mm gt o 30 l 0 50 0 100 0 150 0 200 0 250 0 3000 mm 0 1 97 3 90 5 90 7 87 9 84 11 81 in DEPTH OF
8. nting See pictures below Horizontal Mounting Vertical Mounting se Connecting to the Host The scanner connects to a host terminal by an interface cable This cable connects to the scanner with a modular connector and connects to the host terminal with the con nector required by the host RS 232 keyboard wedge or USB Different connectors used depending on the host Please make sure the right cable is used for connecting the scanner to your host terminal Setting Up the Scanner No set up is required if the scanner is either pre programmed or it auto detects and is ready to be used Otherwise the scanner must be informed about the type of system it is con nected to This can be done quickly using the Programming Guide that s included in the package The Programming Guide is used to set parameters such as communication interface type RS 232 Keyboard USB beep tone beep volume sleep mode timing and same code delay time Set up of a parameter does not interfere with another parameter Scan Test 1 With the scanner running LED red and the host sys tem on scan few known good barcodes 2 Check result on host screen If scanner is reading correctly no further set up is necessary If scanner reads incorrectly then go to Set Up next Set Up 1 With the scanner running LED red and the host sys tem on scan lt Enter Exit Programming Mode gt bar code found on the inside cover of the Programming G
9. ntrolled from the host system via the RS 232C interface Control can be accomplished by trans mitting the following single byte commands to the scanner The default setting for the commans are as follows ASCII Code Function Byte is Also Called OE Hex enable resumes Shift Out or lt Ctrl N gt disable OF Hex disable Shift In or lt Ctrl O gt 05 Hex power up re ini ENQ or lt Ctrl E gt tialization 12 Hex sleep DC2 lt Ctrl R gt 14 Hex wake up DC4 lt Ctrl T gt resumes sleep Note When the scanner is disabled the motor of the scan ner will stay on until the scanner goes into sleep mode Maintaining the Scanner The scanner rarely needs any maintenance only an occa sional cleaning of the scanner window is necessary to remove any dirt or fingerprint To clean the scanner window use a soft lint free cloth and non abrasive cleaner to avoid scratching the scanner window The scanner window can be cleaned while the scanner is running 10 Specifications Operational Light source Depth of Scan Field Number of Scan Lines Scan Pattern Scan Speed Minimum Bar Width Print Contrast Indicators LED Decode Capabilities Beeper Operational System Interfaces Physical Height Depth Width Weight Cable 650nm visible laser diode 0 210mm UPC EAN 100 PCS 90 20 5 directions of scan field 1200 scan per second 5mil PCS 90 30 UPC EAN100 two color LED red and
10. st interference when operated in a commercial environment Radio and Television Interference Operation of this equipment in a residential area can cause interfer ence to radio or television reception This can be determined by turning the equipment off and on The user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the device with respect to the receiver Move the device away from the receiver Plug the device into a different outlet so that the device and the receiver are on different branch circuits If necessary the user may consult the manufacturer an authorized dealer or experienced radio television technician for additional sug gestions The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC20402 U S A Stock No 004000003454 For CE countries This scanner is in conformity with CE standards Please note that an approved CE marked power supply unit should be used in order to maintain CE conformance Laser Safety The Omnidirectional Laser Scan Module complies with safety stand ard IEC 60825 for a Class laser product It also complies with CDRH as applicable to a Class Ila laser product Avoid long term starting into direct laser light
11. the buzzer makes four short beep sounds When the self test is finished the LED light will turn red 5 Place the test barcode in front of the scanner If the scanner works right it will make a short beep sound and the LED will show green light indicating a good read then the test barcode can be removed NOTE 1 2 If the scanner does not make any beep sounds or makes the wrong beep sound or no LED light shows when power is connected remove power from scan ner and refer to troubleshooting section If the scanner is using RS 232 or keyboard wedge interface cables it is able to scan barcodes continu ously when power is on If the scanner is using USB interface cable it will only be able to scan barcodes continuously only when connected to a host If the scanner is not connected to a host it will be able to read one barcode only LED light stays green Mounting 1 2 Scan performance will not be affected by the mount ing direction of the scanner Use mounting holes on the bottom or and back of the scanner to mount the scanner onto host machine templates at the last two pages of the manual can be used Back View Bottom View 64 0 2 52 640 252 Unit mm inch bil SR strain release that is connected to the cable rotates 90 to comply with the way the scanner is mounted Therefore the scanner will be positioned horizontally to the host machine without cable inter ference for optimal mou
12. uide 2 Scanner is ready for programming if it gives one low beep sound followed immediately by a high beep sound and LED turns green 3 Find the barcode which corresponds to the parameter you require in the Programming Guide 4 Scan the desired barcodes one by one as the scan ner beeps once for every barcode it memorizes 5 When all finished scan lt Enter Exit Programming Mode gt barcode again The scanner will beep twice one long and one short When LED turns red the scanner has been programmed 6 Test scan few known good barcodes to make sure the scanner reads correctly If not try set up proce dures again Operation This scanner is omnidirectional reading barcodes in sweep and presentation mode depending on the host system it is attached to Sweep mode means moving items through the scan window left to right right to left top to bottom bottom to top etc are all okay Presentation mode is when an object is moved toward the scan winow presented until the barcode is read then the object is removed LED indications LED Status Indications off no power applied to the scanner steady red light the scanner is on and ready to scan one blink of green light one barcode has been succesfully decoded steady green light scanner is in programming mode a barcode has been successfully decoded but the object has not been removed from the scan win dow flashing red light
13. ure that all ca bles are connected and your host system is ready to receive data Barcode is read by The communication cable is not the scanner but not connected to the serial port of your accepted by the host host system Refer to the manual of system your host system to locate the serial port The communication setting of the system and scanner do not match Adjust the setting to fix the problem The communication cable does not suit your host system Contact your dealer for the correct communica tion cable The software running on the host system does not support the data format of the label 16 Notes Notes Scale 1 1 Unit mm Note 3 Mounting Holes size M3 0 5 Depth 5 0 Figure 1 Mounting Plate Boring Template Back View Scale 1 1 Unit mm Note 2 Mounting Holes size M3 0 5 Depth 4 5 Figure 2 Mounting Plate Boring Template Bottom View Part no MUL 53252 01

Download Pdf Manuals

image