Contents
1. 40 C Lu Pressure operation Bar 3 3 3 xc VY Voltage operation Volt Hz 220 50 MB 25 17 Engine power s Burner Watt 90 MB 40 50 1 amp 1 4 Room thermostat SIEMENS RAA 30 26 S Three speed a iw Circulator Watt 52 77 110 O O ad Fuel type Heating oil yer Hi Heigth A MM 930 954 954 a Length B MM 420 500 500 ral Depth I MM 620 715 715 FILLING VALVE Chimney MM 102 102 102 Weigth kev Kgr 120 135 160 Technical characteristics can change without warning MANUAL MASTER BOILER 03062005 ISO 9001 CE ISCIR PUBLISH 1 DATE 03062005 TH ERMOLEV Page 2 5 Operating instructions and electrological connection of control panel Master Boiler BUTTON 01 DISPLAY BUTTON 02 KAYETHPAS ON LAMP 01 BUTTON 03 i KYKAOOOPHTHE ON LAMP 02 BUTTON 04 0 KYKAQMA NPO TA IAZ LAMP 03 MNAOK KAYSTHPA LAMP 04 LAMP 05 DISPLAY shows the temperature of the boiler when it is standing Parameters in the programming any damages of the boiler BUTTON 01 Increases the indication we wish to regulate BUTTON 02 Decreases the indication we wish to regulate BUTTON 03 Choose the parameter to regulate it PARAMETERS t 1 Temperature where the burner stops d 1 Low hysteresis of the burner temperature ti t 2 Temperature where the circulator starts The operation of heating d 2 Low hysteresis of the circulator temperature t2 t 3 temperature where the circulator starts the Oper
2. T 04 N Ll Q Z lt O O Gi lt O I Operation of the room thermostat The top switch activate the operation of hot water production The bottom switch activate the operation of heating With rotary switch select the room temperature you wish for Activating both switches we have heating and hot water simultaneously Faults indication and solutions E 1 Sensor problem short circuit sensor cut sensor Unable temperature sensor to read Possible exit of the sensor from its position After you identify and solve the problem activate again the boiler when the burner stops Gearing of the burner After we identify and solve the problem we activate the burner from the red switch which is located on the burner Notice For any problem of the boiler you must contact your certified technician Do not interfere other people MANUAL MASTER BOILER 03062005 ISO 9001 CE ISCIR PUBLISH 1 DATE 03062005 TH ERMOLEV Page 5 5 Installation instructors For the installation of Master boiler the following hardware need to be connected Expansion tank 24lt in the heating circuit or bigger than that if it is required by the installation Safety valve 1 2 3BAR Automatic air vent of 2 pieces or more depending on the installation Filling valve 12 with manometer Magnesium anode for protection against salt Blackflow prevender in hot water circuit Expansion tan
3. THERM Q LEV Instruction and operation manual Master boiler series Steel hot water boiler THERMOLEV Page 1 5 Technical manual and user manual of hot watre boiler Master Boiler Heating and hot water THERMOLEV company thanks you for your trust in our products This manual is referred to the technical characteristics of the boiler and provides information on installing and using the boiler Please read very carefully the warranty booklet and follow all the conditions After installation certified technician should sign the quarantee and the correct coupon must be returned in our company Master Boiler is an individual boiler for heating and for the production of hot water Master boiler includes burner circulator electronic control panel thermostat Notice Furthermore a silencer chimney can be fitted where it is not possible the existence of an internal chimney Hydraulic connection of Technical characteristics and Master Boiler External dimensions C gt A Lu Ww xO wW gt Os zx lt x u S gt lt O q Ei a i lt 7 D Technical Mov a Type WY 3 ro Characteristics M tpnonc MB 25 MB 40 MB 50 gt b Nominal output Kcal h 25 500 40 400 50 200 a Kw 30 1 47 58 1 Hot water use Kcal h 25 500 40 400 50 200 Kw 30 1 47 58 1 x Production im SZ Hot water L H 700 750 800 x lt o m AO
4. ation of hot water and heating simultaneously d 3 Low hysteresis of the circulator temperature t3 S t Application BUTTON 04 Switch ON OFF of the boiler LAMP 01 lights when the boiler operates LAMP 02 lights when the circulator operates LAMP 03 lights when the circuit protection is activated LAMP 04 lights when the burner block LAMP 05 lights when the boiler is activated Programming Press for 2 continiously SET to enter the programming With up and down arrows adjust the parameters To go to the next parameter press SET When you get to sign S t has finished programming After this procedure temperature appears again on the display Recommended parameter values C12 72 d1 2C t2 45 C d 2 2 C t3 64 C d3 2 C Notice All the control panels are preset from the factory MANUAL MASTER BOILER 03062005 I 1 CE ISCIR PUBLISH 1 DATE 03062005 ers pi T H E RM Q L EV Page 3 5 Protection Circuit Warm protection If for some reason overcome 92 C circulator is activated and lowers the temperature of the boiler 88 C Burners off If short circuit fault appears in the sensor If sensor is being cut If sensor for any reason stops working Temperature variation Sensor is removed from its position Frost protection If the boiler temperature drops to 2 C the burner is automatically activated and raises the temperature of the boiler to 8 C Circulator protection Automatic activation of
5. iator is located or in a wall that tubes exists 3 Also not to be placed near a window or a balcony door MANUAL MASTER BOILER 03062005 ISO 9001 CE ISCIR PUBLISH 1 DATE 03062005 T H E RM Q L EV site www thermolev com e mail thermolev thermolev com THERMOLEV tel 0030 2310 780761 2 Fax 0030 2310 780814 Thessaloniki Greece
6. k 8lt in hot sanitary water circuit Pressure reducer in hot sanitary water circuit since we have increased pressure in our network CON DUBRWNF Master Boiler connection 1 The hydraylic connection of the boiler is based on a project and you can find it on this booklet as well as at back side of the boiler 2 You should avoid connecting the boiler tuborama with the hot water circuit 3 The electrical cinnection is based on the diagram of the manual Boiler settings 1 The pressure of the heating circuit should be regulated by 1 1 5 BAR 2 For proper and economical operation the setting of the burner should be done by a licensed technician 3 The temperature at which the burner stops is preset 4 The temperature at which the circulator stops is preset Boiler maintenance 1 It is necessary the annual cleaning of the boiler as well as cleaning and adjusting the burner by a licensed burner technician 2 It is also necessary a periodic cleaning of the heat exchanger coil to prevent icing salts Otherwise alternator will be blocked The cleaning is done by special liquids that you can find in the market Time of regular cleaning depends on the hardness of the water and the frequency of use of the boiler Room thermostat installation 1 Thermostat should be placed in the room that concerns us more the changes in temperature 2 Thermostat should not be placed near a radiator in front of a wall that just behind a rad
7. the circulator at time periods in order to avoid obstacles Master Boiler Control panel link HEATING COMMAND 01 OoOO HOT WATER COMMAND 02 o0 PHASE OF ROOM 4 THERMOSTAT 03 NEUTRA ROOM THERMOSTAT 04 o0 WHEN BURNER STOPS 05 O O CIRCULATOR PHASE 07 OoOO NEUTRAL BURNER CIRCULATOR 08 o0 GROUNDING BURNER CIRCULATOR 09 O O GROUNDING 10 O O NEUTRAL 11 OOl oazH 12 O O LINE TKY TKA LINE a GRD Feeding voltage AC 220V 50Hz Internal safety of the control panel F 5A 220V MANUAL MASTER BOILER 03062005 CE PUBLISH 1 DATE 03062005 h a THERMOLEV Page 4 5 Room thermostat connection drawing SIEMENS RAA 30 26 m m mMm m L N N aa 44 WH O gt gt J al a l kal l EE Instructions Before connecting the thermostat you should remove the bridge 1 2 amp 3 of the terminal block panel MASTER BOILER You should make the bridge in the thermostat terminal block YI L4 amp L L5 As shown in the diagram Can connect more than one room thermostat in parallel Boiler operation of the room thermostat With the electronic table and the room thermostat can operate in three different independent functions 1 Boiler for heating 2 Boiler for hot water production 3 For heating and hot water simultaneously ROOM THERMOSTAT 03 NEUTRAL HEATING COMMAND 01 PHASE ROOM THERMOSTA