1. Wait for the System Display message stating unit is operational Turn on the Output Breaker OMNONRWOND M www dspmanufacturing co ee Phone 714 970 2304 System Display Panel Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com History Log Key The History Log is used to record certain events that reflect the status and operating mode of the unit There are 64 lines 00 through 63 It is read by holding down the Alarm Scan button Each time the button is pressed the log is read sequentially with the most recent event being displayed first After 00 is displayed the system will cycle around to 63 After 64 events are logged the system will start recording again at 00 Code Message Description 00 00 Blank used in clearing Alarm History 01 alarm clr Alarm History has been cleared 02 Phase SEQ Input phase sequence has caused a fault and must be changed 04 Input OV Input voltage has gone over fault limit 05 Input UV Input voltage has gone below fault limit 07 Input CONT System has failed to detect closure of the Input Contactor 08 Outpt HiV Output voltage has gone over fault limit 09 Output LoV Output voltage has gone
2. N Verify that Input cable and conduit are routed correctly and are in position to connect the unit Open front doors of UPS Select desired mounting hole and remove knockout Pass wires through the mounting hole Secure conduit fitting to the panel of unit Connect input bypass wires to the TB1 input as indicated by the label Connect input rectifier wires to TB2 input as indicated by the label These connection will be Ground Neutral Hot or Ground Hot Hot Both of these inputs are pre wired to the input circuit breakers CB1 and CB2 E E Input terminals blocks and breaker G N H GHH Bypass Input Rectifier Input Bypass Input Rectifier Input Circuit Breaker Circuit Breaker TB1 TB2 CB1 CB2 Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com 15 DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com 2 3 OUPUT CONNECTIONS 1 Verify that power source to the unit is OFF locked and tagged according to OSHA requirements Verify that the output voltage as stated on the UPS nameplate matches the actual output voltage of the unit Ensure that the intended connected load does not exceed unit capacity If the voltage does not match or the intended applied load exceeds unit capacity STOP installation of the UPS and contact Customer Service at DSPM N Verify that Output cabl
3. 00 after hours 951 840 0811 Web Page Email INC AL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com Typical right hand view Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com 10 INC DIGITAL SIGNAL POWER MANUFACTURER WWwW DSPManufacturing com 1 3 PRODUCT FEATURES The following describes the major sub systems within the POWER LYNX 1 UPS INPUT AND OUTPUT FILTER The input filter reduces the input transients and harmonics on the input line This helps protect the electronic circuitry of the UPS The output filter filters and noise and line spikes from loads INPUT POWER FACTOR CORRECTION The POWER LYNX 1 UPS system includes state of the art input power factor correction This greatly reduces the amount of current demanded from your building wiring system yielding a highly efficient Building Friendly UPS System RECTIFIER INVERTER The Rectifier Inverter system provides controlled sine wave power to the output The output voltage and frequency are monitored by the microprocessor and controlled to provide precision power with changing inputs and outputs to the UPS system MICROPROCESSOR Display The microprocessor monitors the input and the output to the UPS system and corrects for any abnormal condition that may occur This is displa
4. 4 Equipment should be locked at all times 5 Only DSPM trained personnel should be permitted to service or maintain equipment 6 Only accessories recognized by DSPM shall be used with this equipment Contact DSPM if options are desired Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com BATTERY SHELF LIFE STORAGE The batteries must be recharged every 4 months for at least eight hours or the batteries can be damaged If the UPS is placed in storage failure to re change batteries will invalidate your warranty BATTERY SAFETY 1 Person knowledgeable of batteries and the required precautions should perform servicing of batteries Do not dispose of batteries in a fire The battery may explode Do not open and manipulate the battery A battery can present a risk of electrical shock and high short circuit current Remove watches rings or any other metal objects Use only insulated tools 5 Install in a protected environment 6 Always turn off the battery circuit breaker before testing or performing maintenance on the battery system ON WARNING It is strongly advised not to open the UPS cabinet as the components have very high voltages and touching them may be fatal Only a technician from DSPM or a DSPM traine
5. FT o RELATIVE HUMIDITY 0 to 95 non condensing Operating the UPS and batteries at either extreme of the temperature range may affect the long term reliability of the system This is especially true of the sealed maintenance free batteries Sealed maintenance free batteries are designed to operate at normal room temperatures 72 to 77 F WARNING BATTERY SHELF LIFE e BATTERY SHELF LIFE WHEN STORED UNDER TEMERATURE CONDITIONS of 66 F 77 F is FOUR 4 MONTHS MAXIMUM AFTER THE SHIP DATE e BATTERY MUST BE RECHARGED FOR EIGHT HOURS AFTER THIS DATE OTHERWISE THEY MAY BE DAMAGED Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com SECTION 2 INSTALLATION The POWER LYNX 1 UPS system is shipped on a pallet with the batteries outside the UPS This Manual battery jumper wires and accessories may be included within the packaging ensure that these are not discarded with the packaging Unwrap the UPS and carefully inspect the external surfaces for abrasions indentations or other obvious damage File a claim with the shipping agency for any damage caused by shipping Forward a copy of the damage claim to DSPM Mount the UPS system so each side and the top has six inches of clearance for airflow Leave appropriate s
6. below fault limit 10 Outpt OFrq Output frequency has gone over fault limit 11 Outpt UFrq Output frequency has gone below fault limit 12 Phase FLT Input phase sequence fault has not been corrected and system has timed out 13 Invrtr FLT a hardware fault has been detected by the inverter control board IGBT PCBA caused by IGBT failure unexpected power on reset or DC Bus over voltage 14 DC Bus OV DC Bus has gone over fault limit 15 DC Bus UV DC Bus has gone below fault limit 16 Input OFrq Input frequency has gone over fault limit 17 Input UFrq Input frequency has gone below fault limit 18 RECT off Rectifier has shut off unexpectedly 20 Invrt Ofrq Inverter frequency has gone over fault limit 21 Invrt UFrq Inverter frequency has gone below fault limit 22 ISBS open Inverter Static Bypass Switch has not engaged and system has timed out 23 USBS fault Utility Static Bypass Switch has failed test 24 USBS short Utility Static Bypass Switch failure output voltage still detected after off command was issued 26 Output OVL Output Current has gone over fault limit 28 Estop OPEN Emergency Stop option enabled during system power up 35 UPS abort System faults have caused system to switch to bypass 36 Normal run Automated system test concluded 37 BATT test Automated system test initiated 15 minute rectifier shutoff and battery Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 081
7. 1 Web Page www DSPManufacturing com Email sales dspmanufacturing com 19 INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com run 38 Inv start Inverter has been started and matched with utility voltage 40 NMI trap NMI button on processor board has been pressed date and time marker 41 STKUF trap Software Stack underflow detected 42 STKOF trap Software Stack overflow detected 43 WDTMR trap Software has detected a Watchdog timer overflow 45 ISBS xfer Static Bypass Switch has transferred load to Inverter 46 Inv Stop Inverter has unexpected shut off 47 Pwr on RST CPU initialization complete 49 ESTOP trap Emergency Stop option has caused an emergency transfer to utility 50 RunStateO Power has been applied to system 51 RunState1 Initial system checks complete awaiting DC breaker closure 52 RunState2 Startup complete system ready 53 RunState3 Utility power failure system is on a battery run 54 Bypass on System is in bypass 56 Battry Low Battery Voltage is low causes a system shutdown 57 KeyCode OK Key Code Accepted 58 AirFlow DN AirFlow fault detected DC BUS set to minimum value MESSAGE HISTORY CODE LINE DATE TIME SPM www dspmanufat uri t AL POWER MANERE TUBER Phone 714 970 2304 ALARM SCAN Verify that the output voltage as stated on the UPS nameplate matches the actual output voltage of the unit Ensure that the in
8. 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com 23 DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com 2 Check the torque of each battery connection for 70in lbs CAUTION DO NOT OVER TORQUE THESE CONNECTION AS SOME BATTERIES HAVE LEAD POSTS AND THEY ARE VERY EASY TO COMPRESS AND WILL CAUSE FAILURES IN THE FUTURE Note If Batteries are found to be leaking or fail the load test they should be replaced Consult DSPM as to the status of your Battery Warranty TIGHTENING TORQUE POUND INCHES N m SIZE OF WIRE THAT IS TO BE USED FOR CONNECTION OF THE UNIT HEXAGONAL HEAD EXTER ER NAL DRIVE SOCKET WRENCH SPE A 85 0 107 2 127 177 7 0 TROUBLE SHOOTING If unable to resolve any problem please contact DSPM PowerClone for assistance DSPM PowerClone 5407 E La Palma Avenue Anaheim CA 92807 714 970 2304 714 970 6171 customerservice dspmanufacturing com Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com 24
9. GITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com e Check wiring for proper routing and damage such as chaffing and or cutting Relocate and or repair and found damaged wires f Check the torque of each battery connection for 70in Ibs CAUTION DO NOT OVER TORQUE THESE CONNECTION AS SOME BATTERIES HAVE LEAD POSTS AND THEY ARE VERY EASY TO COMPRESS AND WILL CAUSE FAILURES IN THE FUTURE Note If Batteries are found to be leaking or fail the load test they should be replaced Consult DSPM as to the status of your Battery Warranty 2 Annual CAUTION BEFORE PERFORMING ANY OF THE FOLLOWING STEPS BESURE THAT THE UPS EMERGENCY LIGHTING INVERTER HAS BEEN TUNED OFF i Perform all Semi annual Maintenance ii Cabinet Electronics 1 Inspect all power connections for loose connections Tighten any that are found loose See the Torque table below 2 Check wiring for proper routing and damage such as chaffing and or cutting Relocate and or repair and found damaged wires 3 Exercise all circuit breakers 4 If there is a distribution internal to the cabinet and or a panel attached to the side of the UPS Emergency Lighting Inverter check the power connections and exercise the breakers in the cabinet iii Batteries Battery Cabinet 1 Check wiring for proper routing and damage such as chaffing and or cutting Relocate and or repair and found damaged wires Phone 714 970 2304 Fax 714 970 6171 Service
10. INC ITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com DS PM Inc User s Manual Power Lynx 1 Uninterruptible Power System Technical Manual 018 0056 10 Revision nr Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com Congratulations on selecting one of the fine products from DSPM the leader in power protection technology Our wide product offering includes Uninterruptible Power Systems UPS Power Conditioners Frequency Converters and Specialty Transformers Since our beginnings DSPM has shipped many of these fine products to discerning customers for use on sensitive equipment and critical loads HEADQUARTERS DSPM Inc 1921 S Quaker Ridge Place Ontario Ca 91761 SALES Phone 714 970 2304 Fax No 714 970 6171 www DSPManufacturing com Email sales dspmanufacturing com SERVICE Phone 714 970 2304 m f 8 00 AM 5 00 PM Phone 951 840 0811 after 5 00 PM Fax No 714 970 6171 Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com DSPM Inc Proprietary Reproduction or Distri
11. WER MANUFACTURER WWW DSPManufacturing com 6 0 Maintenance CAUTION DO NOT DISPOSE OF BATTERIES IN FIRE CAUTION DO NOT ATTEMPT TO OPEN THE BATTERIES CAUTION THE FOLLOWING PRECAUTIONS SHOULD BE TAKEN WHEN REPLACING ANY BATTERIES e REMOVE WATCHES RINGS ETC e USE TOOLS WITH INSULATED HANDLES CAUTION USE RUBBER PROTECTIVE GLOVES WHEN HANDLING DAMAGED BATTERIES WARNING HIGH VOLTAGE IS PRESENT ON BATTERIES 1 Semi annual i Cabinet Electronics 1 Inspect all fans and insure proper operation ii Batteries Battery Cabinet 1 Inspect the battery cases for leakage 2 Perform a battery load test of each individual battery a Turn off the Battery Breaker b Using a Battery load tester connected to only one battery test the battery and record the battery voltage after a 5 to 10 second load test The picture to the left is an example of the type load tester that can be used c Repeat step b using the same timed load test and record the data d After the testing all the batteries compare the test data All recorded voltages should be approximately the same value Any batteries that have a reading considerably different then the others needs to be investigated or considered to be bad and replaced Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com 22 INC DI
12. ages of 120 208 240 and 277 VAC and output voltages of 277 240 208 and 120 VAC This information is provided on the nameplate located on the inside of the front door 1 2 BENEFITS The POWER LYNX 1 is designed to fit the needs for virtually all power conditioning and UPS applications It has been specifically designed to power all forms of modern data processing communications process control equipment lighting and emergency lighting equipment The UPS does not require any derating as other UPS products may when powering 100 electronic loads including switch mode power supplies The POWER LYNX 1 protects sensitive electrical equipment such as computer systems telecommunication networks LANs multi user systems and instrumentation systems from electrical interference The UPS protects these systems from power problems associated with poor quality AC power including complete power outages Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC ITAL SIGNAL POWER MANUFACTURER WWwW DSPManufacturing com 1 2 BENEFITS continued Electrical disturbances can come from practically anywhere from the incoming power lines and from within a building Outside electrical disturbances include lightning strikes utility switching brownouts and accidents Electrical disturbances from within the buildi
13. bution forbidden NOTICE THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION This document contains proprietary and confidential information of DSPM Inc DSPM In consideration of the receipt of this document the recipient agrees not to copy any of its contents nor disclose them to or allow them to be used by any person not currently a DSPM employee or an employee of the recipient having a need to know without the express written consent of DSPM and further agrees to surrender this document to DSPM when the reason for its receipt has terminated Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com SAFETY Important Safety Instructions save These Instructions This manual contains important instructions for the Power Lynx 1 UPS System and should be followed during the installation operation and maintenance of the UPS system IMPORTANT SAFETY When using Electrical Equipment basic safety precautions should always be followed including the following IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1 Do not mount near gas or electric heaters 2 Check that all electrical connections are tightened properly 3 Equipment should be mounted in a location to prevent tampering by unauthorized personal
14. circuit breaker terminal that is labeled Follow Battery diagram in the unit for installation BATTERY SYSTEM TEST _ Make sure A C input circuit breaker is OFF 2 Make sure battery circuit breakers are OFF 3 Use ameter and note the D C voltage at the battery circuit breaker The voltage must be the correct polarity positive lead of the meter to the positive terminal of the terminal block 4 The D C voltage should read between 220 to 240 VDC for an 18 battery unit and 118 to 130 for a 10 battery unit If the D C voltage reads below 210 volts D C or 115 volts DC this means the battery cables are not connected correctly 5 If the battery polarity and voltage level are correct continue to Starting the UPS Battery Breaker CB3 Battery Terminal Block TB3 Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC ITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com 3 0 OPERATIONS 3 1 STARTING THE UPS Check the input A C circuit breaker is OFF Check all output circuit breaker s optional are OFF Check the battery circuit breaker s are OFF Energize the Utility feeder to the unit Turn the Input circuit breaker ON Wait for the System display message instructing you to close the battery breaker Turn on the Battery Breaker
15. d technician may service the unit Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC ITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com SECTION 1 OPERATION 1 1INTRODUCTION The POWER LYNX UPS uninterruptible power system from DSPM provides an exceptional level of load protection and monitoring capabilities The critical load is provided with conditioned regulated computer grade power at all times Both the voltage level and frequency are controlled at all times to the load When the input power is lost to the UPS such as during a power outage the UPS automatically draws power from its internal battery supply The critical load receives only clean sine wave power at all times There are no disturbances or power interruptions on the output when the UPS transfers to battery operation Transfers to and from battery operations are No Break transfers The internal maintenance free batteries provide a few minutes to hours depending upon model of backup power Upon restoration of input power the UPS automatically resumes normal operation Also the UPS immediately begins to recharge the batteries The POWER LYNX 1 is a dual conversion single phase UPS available in output ratings of 2 to 80 kVA The UPS is ULL listed under UL1778 and or UL924 The UPS is available with input volt
16. e s and conduit s are routed correctly and are in position to connect the unit Open front doors of UPS Select desired mounting hole s and remove knockout Pass wires through the mounting hole Secure conduit fitting to the panel of unit Connect the output wires to the output circuit breaker s neutral and ground terminal blocks Note Ensure that the applied loads wired to the unit are evenly balanced Loads to be evenly distributed to all output circuit breakers provided NO gieo Output Terminal Blocks TB4 G N H Output Circuit Breaker CB4 Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com 16 DIGITAL AL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com 2 4 BATTERIES AND BATTERY CABLES WARNING FOLLOW THE BATTERY SAFETY PROCEDURE IN THE FRONT OF THIS MANUAL If the UPS is provided with batteries the UPS system will have fixed battery trays All battery systems connect the batteries in series i e plus terminal to minus terminal from one battery to another battery The battery circuit breaker must be off during the installation Install the batteries and connect the battery cables Connect the minus terminal of the battery group to the battery circuit breaker terminal that is labeled Connect the positive terminal of the battery group to the battery
17. installed as part of the input circuit Size the grounding conductor in accordance with NEC and local codes The manufacturer recommends a parity sized ground with respect to the input power wires 2 1 INSTALLATION OF EQUIPMENT continued The UPS is designed to provide superior isolation and protection for sensitive loads The UPS can be wired as a separately derived source that allows the re establishing of the ground reference at the output of the UPS This method of installation will provide additional load isolation from noise and other disturbances INSURE THAT ALL CODE REQUIREMENTS ARE FOLLOWED IN GROUNDING THE UPS AND ITS LOADS BODILY INJURY OR DAMAGE TO EQUIPMENT MAY OCCUR IF UNIT IS NOT PROPERLY GROUNDED NOTE The equipment to be connected to the UPS may require special grounding procedures Refer to technical documentation which accompanies that equipment Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com 2 2 INPUT CONNECTIONS 1 Verify that power source to the unit is OFF locked and tagged according to OSHA requirements Verify that the input voltage as stated on the UPS nameplate matches the customer supplied voltage If the voltage does not match STOP installation of the UPS and contact Customer Service at DSPM
18. ng can be caused by load cycling elevators HVAC systems fault conditions welders and other electrically noisy equipment Whether the electrical disturbances are generated outside or from within the facility the following power problems will occur Complete power outages Brown outs including momentary sags Voltage surges Transients including common mode and transverse mode noise e Frequency shifts and fluctuations Sensitive electrical equipment needs protection from power problems Without power protection users of sensitive equipment may experience Loss of data including data corruption Database corruption Equipment and component deterioration Premature equipment failures Unexpected equipment failures Missed deadlines especially during batch processing Loss of real time transaction processing Loss of employee productivity Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC AL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com Ej Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page M 7 Email DS PM INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com Typical left hand view Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5
19. pace in the front so the front door can be opened fully for operation and installation 2 1 INSTALLATION EQUIPMENT The following instructions cover general requirements for standard installation of the input and output power circuits battery connections and control interface connections Install the UPS using the procedures in this section Care must be taken to insure the unit is properly connected Connections should be torque as shown in Table 2 1 TABLE 2 1 WIRING TERMINAL TORQUE Wire Gauge Terminal Torque ANG pound inches neutons so 68 THE UPS CONTAINS POTENTIALLY LETHAL VOLTAGES INSIDE EVEN IF THE UNIT IS NOT CONNECTED TO AN EXTERNAL SOURCE OF POWER ALL INSTALLATION AND SERVICE PROCEDURES SHOULD BE PERFORMED BY QUALIFIED PERSONNEL ONLY Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC TAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com The input power circuit is supplied by the customer This provides power from the building source to the UPS system This circuit should be a dedicated branch circuit that is hard wired in conduit Size the branch circuit feeder conductors according to the specific power rating of the unit Refer to the latest edition of National Electric Code NEC for the exact wire size required An insulated grounding conductor must be
20. tended connected load does not exceed unit capacity If the voltage does not match or the intended applied load exceeds unit capacity STOP installation of the UPS and contact Customer Service at DSPM Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com 20 INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com 3 2 TURNING THE UPS SYSTEM OFF 1 Turn OFF the output circuit breakers 2 Turn OFF the input A C Bypass and Rectifier circuit breakers 3 Turn OFF the battery circuit breaker 4 2 OUTPUT POWER 1 Normally on circuits can be provided These circuits are on when AC input power is on and turned off to lower the load requirements where input AC power fails 2 Normally off circuits can be provided These circuits provide power only when the UPS system is on battery power These circuits usually power exits signs and lighting 5 0 TECHNICAL SUPPORT 1 For Technical Support or any questions not covered in this manual contact DSPM Power Clone 5407 E La Palma Avenue Anaheim CA 92807 714 970 2304 714 970 6171 customerservice dspmanufacturing com Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com 21 DIGITAL AL SIGNAL PO
21. yed on the display for operator information DIAGNOSTIC TESTS When you start the UPS a diagnostic test is automatically executed that checks the electronics batteries and reports and problems on the display Phone 714 970 2304 Fax 714 970 6171 Service 714 970 2304 m f 8 00 5 00 after hours 951 840 0811 Web Page www DSPManufacturing com Email sales dspmanufacturing com INC DIGITAL SIGNAL POWER MANUFACTURER WWW DSPManufacturing com SECTION 2 PREINSTALLATION 2 1 SITE PLANNING AND PREPARARTION The POWER LYNX 1 is designed for installation indoors where it is protected from the elements The UPS can be installed in a variety of different environments including computer rooms offices and industrial process control locations For the best performance and reliability temperature extremes should be avoided Listed below are the environmental specifications for the POWER LYNX 1 UPS SYSTEM Adequate clearance around the equipment should be provided for service access and proper equipment cooling The UPS must be protected from contact with water and other liquids If the UPS is installed in a small enclosed area provisions for additional cooling may be necessary OPERATING ENVIRONMENT Provide an operating environment that meets the following conditions o AMBIENT TEMPERATURE 32 to 104 F 0 to 40 C o OPERATING ALTITUDE 2 286 M 7500 FT o NON OPERATING ALTITUDE up to 3 048 M 10 000
Download Pdf Manuals
Related Search
Related Contents
User manual_(HLWH003B) Pfaff Embroidery Machine User's Manual Toshiba GD-1250 All in One Printer User Manual OM, Gardena, Rasaerba elettrico, Art 04032-20, 2006-01 UPSilon 2000 Pressure 3 types AireRyder LK30304RBZ Instructions / Assembly JBL 404GTi Car Speaker Télécharger le fichier Copyright © All rights reserved.